Art Pro Audio SOLO VLA Manuale del proprietario

Tipo
Manuale del proprietario
Manuel de L' Utilisation
User’s Manual
SOLO VLA
MULTIVOICE TUBE / OPTO COMPRESSOR
APPLIED RESEARCH AND TECHNOLOGY
SOLOVLA
i
DO NOT OPEN THE PROTECTIVE
HOUSING WITH A SCREWDRIVER.
USE OF CONTROLS, ADJUSTMENTS
OR FOLLOWING PROCEDURES
OTHER THAN AS DESCRIBED
HEREIN MAY RESULT IN HAZARD-
OUS RADIATION EXPOSURE.
Laser Information
This product contains a solid state laser
system within its enclosure and is classied
as a “CLASS 1 LASER PRODUCT”. To
avoid exposure to the laser beam, do not
attempt to open the box. tJ•W•Ma
CAUTIONS ABOUT BATTERIES
This product uses batteries. Misuse of
batteries could cause a leak, rupture or
other trouble. Always abide by the following
precautions when using batteries.
Never recharge non-rechargeable batter-
ies. The batteries could rupture or leak,
causing re or injury.
When installing batteries, pay attention to
the polarity indications (plus/ minus(+/-)
orientation), and install them correctly in
the battery compartment as indicated.
Putting them in backward could make
the batteries rupture or leak, causing re,
injury or stains around them.
When you store or dispose batteries,
isolate their terminals with insulation tape
or something like that to prevent them from
contacting other batteries or metallic objects.
Compliance of radio transmit-
ter and interference
This product has the function of broadband
transmitter using 2.4 GHz Band.
Use frequency range: 2400 MHz - 2480 MHz
Maximum output power: Bluetooth®
Class2 (less than 2.5 mW)
CAUTION
Use only in the country where you pur-
chased the product.
Authorization of wireless devices are
dierent in countries or regions.
Depending on the country, restrictions
on the use of Bluetooth wireless tech-
nology might exist.
Radiation Exposure requirements
This equipment meets the regulation, which
is recognized internationally, for the case of
human exposure to radio waves generated
by the transmitter.
Radiation Exposure requirements
This equipment complies with EN.6231 1;
Assessment of electronic and electrical equip-
ment related to human exposure restrictions
for electromagnetic elds; the harmonized
standard of DIRECTIVE 2014/ 53/ EU.
For European Customers
Disposal of electrical and electronic equip-
ment and batteries and/or accumulators
(a) All electrical/ electronic equipment and
waste batteries/accumulators should
be disposed of separately from the
municipal waste stream via collection
facilities designated by the govern-
ment or local authorities.
(b) By disposing of electrical/electronic
equipment and waste batteries/accu-
mulators correctly, you will help save
valuable resources and prevent any
potential negative eects on human
health and the environment.
(c) Improper disposal of waste electrical/
electronic equipment and batteries/
accumulators can have serious eects
on the environment and human health
because of the presence of hazardous
substances in the equipment.
(d) The Waste Electrical and Electronic
Equipment (WEEE) symbols, which
show wheeled bins that
have been crossed out,
indicate that electrical/
electronic equipment and
batteries/accumulators
must be collected and
disposed of separately
from household waste.
If a battery or accumulator contains
more than the specied values of lead
WARNING
Pb, Hg, Cd
Wireless
Equipment
Precautions
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SER-
VICING TO QUALIFIED SERVICE PERSONNEL.
The lightning ash with arrowhead symbol, within equilateral triangle, is intended to
alert the user to the presence of uninsulated “dangerous voltage” within the product’s
enclosure that may be of sucient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
S. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings.
Install in accordance with the manufactur-
er’s instructions.
8. Do not install near any heat sources such
as radiators, heat registers, stoves, or
other apparatus (including ampliers)
that produce heat.
9 . Do not defeat the safety purpose of the po-
larized or grounding-type plug. A polarized
plug has two blades with one wider than
the other. A grounding type plug has two
blades and a third grounding prong. The
wide blade or the third prong are provided
for your safety. If the provided plug does
not t into your outlet, consult an electrician
for replacement of the obsolete outlet.
10. Protect the power cord from being walked
on or pinched particularly at plugs, conve-
nience receptacles, and the point where
they exit from the apparatus.
11. Only use attachments/accessories speci-
ed by the manufacturer.
12. Use only with the cart, stand, tripod, bracket,
or table specied by the manufacturer, or
sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
The apparatus draws nominal non-operating
power from the AC outlet with its POWER or
STANDBY/ON switch not in the ON position.
The mains plug is used as the disconnect
device, the disconnect device shall remain
readily operable.
Caution should be taken when using
earphones or headphones with the product
because excessive sound pressure (vol-
ume) from earphones or headphones can
cause hearing loss.
Do not expose this apparatus to drips
or splashes.
Do not place any objects lled with liq-
uids, such as vases, on the apparatus.
Do not install this apparatus in a conned
space such as a book case or similar unit.
Products with Class I construction are
equipped with a power supply cord that
has a grounding plug. The cord of such a
product must be plugged into an AC outlet
that has a protective grounding connection.
To prevent possible
hearing damage, do not
listen at high volume
levels for long periods.
CAUTION
WARNING
WARNING
13. Unplug this apparatus during lightning storms
or when unused for long periods of time.
14. Refer all servicing to qualied service
personnel. Servicing is required when the
apparatus has been damaged in any way,
such as power-supply cord or plug is dam-
aged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not
operate normally, or has been dropped.
RACK-MOUNTING THE UNIT
Use the supplied rackmount screw kit to
mount the unit in a standard 19-inch rack,
as shown below.
Remove the feet of the unit before mounting.
Leave 1 U of space above the unit
for ventilation.
Allow at least 10 cm (4 in) at the rear of
the unit for ventilation.
CAUTION
The apparatus should be located
close enough to the AC outlet so that
you can easily g rasp the power cord
plug at any time.
If the product uses batteries (including a
battery pack or installed batteries), they
should not be exposed to sunshine, re
or excessive heat.
CAUTION for products that use replace-
able lithium batteries: t here is danger of
explosion if a battery is replaced with an
incorrect type of battery. Replace only
with the same or equivalent type.
When throwing used batteries away, follow
the disposal instructions indicated on the
batteries and t he local disposal laws.
Do not use batteries other than those
specied. Do not mix and use new and
old batteries or dierent types of batteries
together. The batteries could rupture or leak,
causing re, injury or stains around them.
Do not carry or store batteries together with
small metal objects. The batteries could
short, causing leak, rupture or other trouble.
Do not heat or disassemble batteries. Do
not put them in re or water. Batteries could
rupture or leak, causing re, injury or stains
around them.
If the battery uid leaks, wipe away any uid
on the battery case before inserting new
batteries. If the battery uid gets in an eye,
it could cause loss of eyesight. If uid does
enter an eye, wash it out thoroughly with
clean water without rubbing the eye and then
consult a doctor immediately. If the uid gets
on a person’s body or clothing, it could cause
skin injuries or burns. If this should happen,
wash it o with clean water and then consult
a doctor immediately.
The unit power should be o when you install
and replace batteries.
Remove the batteries if you do not plan to
use the unit for a long time. Batteries could
rupture or leak, causing re, injury or stains
around them. If the battery uid leaks, wipe
away any uid on the battery compartment
before inserting new batteries.
Do not disassemble a battery. The acid in-
side the battery could harm skin or clothing.
(Pb), mercury (Hg), and/or
cadmium (Cd) as dened
in the Battery Directive
(2006/66/ EC), then the
chemical symbols for those
elements will be indicated
beneath the WEEE sym-
bol. Pb, Hg,Cd
(e) Return and collection systems are
available to end users. For more
detailed information about the disposal
of old electrical/electronic equipment
and waste batteries/accumulators,
please contact your city oce, waste
disposal service or the shop where you
purchased the equipment.
DOC-ART-Safety-AC-Eng-Fre-00-1v0 • August 17/2022
ENGLISH
Important Safety Instructions - English
ii
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT: POUR PRÉVENIR LES RISQUES D’INCENDIE ET D’ÉLECTROCUTION, N’EXPOSEZ PAS CET APPAREIL À LA PLUIE NI À L’HUMIDITÉ.
ATTENTION: POUR RÉDUIRE LE RISQUE D’ÉLECTROCUTION, NE RETIREZ PAS LE CAPOT (OU
L’ARRIERE). AUCUNE PIECE INTERNE N’EST RÉPARABLE PAR L’UTILISATEUR. CONFIEZ TOUTE
RÉPARATION A UN SERVICE APRES-VENTE QUALIFIÉ.
Le symbole d’éclair à tête de èche dans un triangle équilatéral sert a prévenir l’utilisa-
teur de la presénce dans l’enceinte du produit d’une « tension dangereuse » non isolée
d’une grandeur susante pour constituer un risque d’électrocution pour les personnes.
Le point d’exclamation dans un triangle équilatéral sert à prévenir l’utilisateur de la
présence d‘instructions importantes de fonctionnement et de maintenance (entre-
tien) d ans les documents accompagnant l’appareil.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Tenez compte de tous les avertissements.
4. Suivez toutes les instructions.
5. N’utilisez pas cet appareil avec de l’eau à proximité.
6. Ne nettoyez l’appareil qu’avec un chiffon sec.
7. Ne bloquez aucune ouverture de ventilation.
lnstallez-le conformément aux instructions
du fabricant.
8. N’installez pas l’appareil près de sources de chaleur
telles que des radiateurs, bouches de chauffage,
poeles ou autres appareils (y compris des amplica-
teurs) degageant de la chaleur.
9. Ne neutralisez pas la fonction de sécurité de la
che polarisée ou de terre. Une che polarisée
a deux broches, l’une plus large que l’autre. Une
che de terre à deux broches identiques et une
troisieme broche pour la mise à la terre. La broche
plus large ou la troisième broche servent à votre
sécurité. Si la che fournie n’entre pas dans votre
prise, consultez un électricien pour le remplace-
ment de la prise obsolète.
10. Évitez de marcher sur le cordon d’alimentation et
de le pincer, en particulier au niveau des ches, des
prises secteur, et du point de sortie de l’appareil.
11. N’utilisez que des xations/accessoires spéciés
par le fabricant.
12. Utilisez-le uniquement avec des chariots, socles,
trepieds, supports ou tables specifies par le
fabricant ou vendus avec l’appareil. Si un chariot
est utilise, faites attention a ne pas etre blesse
par un renversement lors du deplacement de
!’ensemble chariot/appareil.
L’appareil tire un courant nominal de veille de la
prise secteur quand son interrupteur POWER ou
STANDBY /ON n’est pas en position ON.
La che secteur est utilisée comme dispositif de
déconnexion et doit donc toujours rester disponible.
Des précautions doivent être prises en cas d’utilisa-
tion d‘écouteurs ou d‘un casque avec le produit car
une pression sonore excessive (volume trop fort)
dans les écouteurs ou dans le casque peut causer
une perte auditive.
N’exposez pas cet appareil aux gouttes ni
aux eclaboussures.
• Ne placez pas d’objet rempli de liquide sur
l’appareil, comme par exemple un vase.
N’installez pas cet appareil dans un espace conné
comme une bibliotheque ou un meuble similaire.
L’appareil doit être place suffisamment près
de la prise de courant pour que vous puissiez
Les produits ayant une construction de Classe I sont
équipés d’un cordon d’alimentation avec une che
de terre. Le cordon d’un tel produit doit être branche
dans une prise secteur avec terre de sécurité.
Pour éviter d’éventuels dommages
auditifs, n’écoutez pas de façon
prolongée à niveau sonore élevé.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
13. Débranchez cet appareil en cas d’orage ou de
non-utilisation prolongée.
14. Conez toute réparation à des techniciens de main-
tenance qualiés. Une réparation est nécessaire si
l’appareil a été endommagé d’une quelconque façon,
par exemple si le cordon ou la che d’alimentation est
endommagé, si du liquide a été renversé sur l’appareil
ou si des objets sont tombés dedans, si l’appareil a
été exposé à la pluie ou à l’humidité, s’il ne fonctionne
pas normalement, ou s’il est tombé.
MONTAGE EN RACK DE L’UNITÉ
Utilisez le kit de vis pour montage en rack pour
monter l’unité dans un rack 19” standard, comme
représenté ci-dessous.
Retirez les pieds de l’unité avant le montage.
• Laissez 1 U d’espace au-dessus de l’unité pour la
ventilation.
• Laissez au moins 10 cm à l’arrière de l’unité pour
la ventilation.
ATTENTION
• N’OUVREZ PAS LE BOÎTIER DE PROTECTION
AVEC UN TOURNEVIS.
• L’UTILISATION DE COMMANDES, DE RÉGLAG-
ES OU LE SUIVI DE PROCÉDURES AUTRES
QUE CE QUI EST DÉCRIT DANS CE DOCU-
MENT PEUT PROVOQUER UNE EXPOSITION À
UN RAYONNEMENT DANGEREUX.
Informations Sur Le Laser
Ce produit contient un système laser à semi-con-
ducteurs dans son boîtier et est classé comme «
PRODUIT LASER DE CLASSE 1 ». Pour éviter d’être
exposé au faisceau laser, n’essayez pas d’ouvrir le
boitier. tJ•W•Ma
PRÉCAUTIONS CONCERNANT LES PILES
Ce produit utilise des pi les. Le mauvais usage des
piles peut provoquer une fuite, une rupture ou d’au-
tres problèmes. Respectez toujours les précautions
suivantes pour l’emploi de pi les.
• Ne rechargezjamais des piles non rechargeables.
Les piles peuvent se rompre ou fu ir, risquant de
causer un incendie ou des blessu res.
• Lors de l’installation des piles, faites attention
aux indications de polarité (orientation plus/moins
(+/ - )) et installez-les correctement dans le com-
partiment des piles comme indiqué. Les installer
à l’envers peut entrainer la rupture ou la fuite des
pi les, source d’incendie, de blessure ou de dégât
autour d’elles.
• Quand vous rangez ou jetez des piles, isolez leurs
bornes avec de l’adhésif isolant ou avec un matéri-
au équivalent ur leur éviter d’entrer en contact
avec d’autres piles ou des objets métalliques.
Lorsque vous jetez les pi les usagées, suivez les
instructions demise au rebut indiquées sur les piles
et les lois locales sur l’enlèvement des ordures.
Conformité de l’émetteur radio et interférences
Ce produit a une fonction émetteur la rge bande
utilisant la bande des 2,4 GHz.
Plage de fréquences utilisée: 2400 MHz - 2480
MHz
Puissance maximale d‘émission: Blue-
tooth® de classe 2 (moins de 2,S mW)
ATTENTION
N’ut ilisez ce produit q ue dans son pays d’achat.
• Les aut orisations accordées aux dispositifs sans
l diffèrent avec les pays ou régions.
• Selon le pays, ii peut exister des restrict ions d’uti
lisation de la technologie sans l Bluetooth.
Exigences Relatives a L’exposition
Aux Rayonnements
Cet équipement satisfait la réglementation reconnue
à l’échelle intern ationale en matière d’exposition
humaine aux ondes radioélectriques générées par
l’émetteur.
Exigences Relatives à L’exposition Aux
Rayonnements
Cet équipement est confo rme à la norme EN.6231:
Évaluation des équipements électroniques et élec-
triques en relation avec les restrictions d’exposition
humaine aux champs électromagnetiques ; la norme
harmonisée de la Directive 2014/53/UE.
Pour Les Consommateurs Européens
Mise au rebut des équipements électriques et
électroniques et des piles et/ou accumulateurs
(a) Tous les équipements électriques et
électroniques et piles/accumulateurs hors
d’usage doivent être traités séparément de
la collecte municipale d’ordures ménagères
dans des points de collecte désignés par le
gouvernement ou les autorités locales.
(b) En vous débarrassant correctement des
équipements électriques/électroniques et piles/
accumulateurs hors d’usage, vous contribuerez
à la sauvegarde de précieuses ressources et à
la prévention de potent iels effets négatifs sur
la santé humaine et l’environnement.
(c) Le traitement incorrect des équipements élec-
triques/électroniques et piles/accumulateurs
hors d’usage peut avoir des effets graves sur
l’environnement et la santé humaine en raison
de la présence de substances dangereuses
dans les équipements.
(d) Le symbole de déchets d’équipements élec-
triques et électroniques (DEEE), qui représente
une poubelle à roulettes barrée
d’une croix, indique que les
équipements électriques/
électroniques et - piles/
accumulateurs doivent être
collectés et traités séparément
des déchets ménagers.
Si une pile ou un accumulateur contient plus que
les valeurs de plomb (Pb), mercure (Hg) et/ou
ATTENTION
Pb, Hg, Cd
Précautions Con-
cernant Les Ap-
pareils Sans Fil
à tout moment attraper facilement la fiche du
cordon d’alimentation.
Si le produit utilise des piles/ batteries (y compris
un pack de batteries ou des batteries xes),
elles ne doivent pas être exposées au soleil, au
feu ou à une chaleur excessive.
PRÉCAUTION pour les produits qui utilisent des
batteries remplaçables au lithium : remplacer
une batterie par un modele incorrect entraine un
risque d’explosion Remplacez-les uniquement par
un type identique ou équivalent.
N’utilisez pas d’autres piles que celles spéciées.
N’utilisez pas en meme temps des piles neuves et
usagees, ni des types de piles differents. Les piles
peuvent se rompre ou fuir, risquant de causer un
incendie, des blessures ou des dégâts autour d’elles.
• Ne transportez pas et ne conservez pas des piles
è côte de petits objets métalliques. Les piles
peuvent entrer en court-circuit, provoquant une
fuite, une rupture ou d’autres problèmes.
Ne chauffez et ne démontez pas les piles. Ne les
jetez pas dans un feu ou dans de l’eau. Les piles
peuvent se rompre ou fuir, risquant de causer un
incendie, des blessures ou des dégâts autour d’elles.
• Si le liquide de la pile s’échappe, essuyez tout
liquide répandu dans le boîtier des piles avant
d’insérer de nouvelles piles. Si le liquide d’une
pile touche un œil, ii peut entraîner une perte de
la vue. Dans ce cas, rincez abondamment à l’eau
claire sans trotter l’œi l et consultez immédiate-
ment un médecin. Si le liquide touche le corps ou
les vêtements d’une personne, ii peut entraîner
des blessures ou brûlures cutanées. Si cela se
produit, rincez abondamment à l’eau claire puis
consultez immédiatement un médecin.
• L’al imentation de l’unité doit être coupée quand
vous installez ou remplacez des piles.
• Retirez les piles si vous envisagez de ne pas
utiliser l’unité durant une période prolongée. Les
piles peuvent se rompre ou fuir, risquant de causer
un incendie, des blessures ou des dégàts autour
d’elles. Si le liquide de la pile s’échappe, essuyez
tout liquide répandu dans le boîtier des piles avant
d’insérer de nouvelles piles.
• Ne démontez pas une pile. L’acide qu’elle contient
peutentraîner des blessures cutanées ou des
dommages aux vêtements.
cadmium (Cd) telles que spéciées
dans la directive sur les piles et
accumulateurs (2006/66/ CE), alors
les symbol es chimiques de ces
éléments seront indiqués sous le
symbole DEEE.
(e) Des systèmes de retour et de collecte sont
disponibles pour l’utilisateur nal. Pour des
informations plus détaillées sur la mise au
rebut des vieux équipements électriques/élec-
troniques et piles/accumulateurs hors d’usage,
veuillez contacter votre mairie, le service
d’ordures ménagères ou le magasin dans lequel
vous avez acquis l’équipement.
FRANÇAIS
Important Safety Instructions - Français
iii
1/4-inch T.R.S.
Phone Plug
Balanced 1/4-inch T.R.S. to Balanced XLR
XLR Plug
(Male)
Tip = 0° Ring = 180°
Sleeve = Ground
1Pin 1 = Ground
Pin 2 = 0°
Pin 3 = 180°
2
3
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Industry Canada licence-exempt RSS
standard(s).
Operation is subject to the following two conditions: (1) This device
may not cause interference,
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Cet équipement a été testé et déclaré conforme aux limites
d'un appareil numérique de classe B, conformément à la
partie 15 des règles de la FCC. Ces limites sont conçues
pour fournir une protection raisonnable contre les inter-
férences nuisibles dans une installation résidentielle. Cet
équipement génère, utilise et peut émettre de l'énergie de
radiofréquence et, s'il n'est pas installé et utilisé
conformément aux instructions, peut causer des inter-
férences nuisibles aux communications radio. Cependant,
il n'y a aucune garantie que des interférences ne se
produiront pas dans une installation particulière. Si cet
équipement cause des interférences nuisibles à la récep-
tion radio ou télévision, ce qui peut être déterminé en
éteignant et en rallumant l'équipement, l'utilisateur est
encouragé à essayer de corriger l'interférence par une ou
plusieurs des mesures suivantes :
• Réorientez ou déplacez l'antenne de réception.
• Augmenter la distance entre l'équipement et le récepteur.
• Branchez l'équipement dans une prise sur un circuit
différent de celui auquel le récepteur est connecté.
• Consultez le revendeur ou un technicien radio/TV
expérimenté pour obtenir de l'aide.
ATTENTION : Les changements ou modifications non expressément
approuvés par la partie responsable de la conformité peuvent annuler
l'autorité de l'utilisateur à faire fonctionner l'équipement.
Cet instrument est conforme aux normes RSS d’Industrie Canada
exemptes de licence.
Le fonctionnement est soumis aux deux conditions suivantes : (1) Cet
appareil ne peut pas causer d’interférence, (2) Cet appareil doit
accepter toute interférence, y compris les interférences qui peuvent
causer un fonctionnement indésirable de l’appareil.
Compliance Class-B
1
Cover .............................................................................. a
Important Safety Instructions - English ............................ i
Important Safety Instructions - Français ......................... ii
Compliance Class-B .......................................................iii
Table of Contents ............................................................1
Introduction .....................................................................2
Parallel Compression ........................................................ 2
Soft-Knee Leveling ............................................................ 2
MultiVoice ........................................................................... 2
Comprehensive Metering .................................................. 2
The Solo VLA’s impressive feature set ............................. 2
Installation ......................................................................3
AC Power Hookup .......................................................... 3
Audio Connections .........................................................3
Applications ....................................................................3
Compressor/ Limiter .......................................................... 3
Vocal and Instrument Leveling .......................................... 3
Front Panel ..................................................................... 4
1. Power Switch ................................................................. 4
2. Threshold Control .......................................................... 4
3. Ratio Control .................................................................. 4
4. Attack Control ................................................................. 4
5. Release Control ............................................................. 5
6. Blend Control ................................................................. 5
7. Voice Switch ................................................................... 5
8. Comp. Switch ................................................................. 5
9. VU Meter Switch ............................................................ 5
10. VU Meter ...................................................................... 5
11. Meter Trim .................................................................... 5
12. Master Output Control ................................................. 5
Rear Panel ......................................................................6
1. I/O Level Switch ............................................................. 6
2. Balanced Inputs ............................................................. 6
3. Balanced Output ............................................................ 6
4. IEC Power Connector .................................................... 6
Introduction .....................................................................7
Compression Parallèle ...................................................... 7
Nivellement Soft Knee ....................................................... 7
MultiVoix ............................................................................. 7
Mesure Complète .............................................................. 7
L’Ensemble Impressionnant des Fonctionnalités du Solo
VLA ..................................................................................... 7
Installation ......................................................................8
Branchement de l’Alimentation CA ................................. 8
Connexions Audio ...........................................................8
Applications ....................................................................8
Compresseur / Limiteur ..................................................... 8
Nivellement des Voix et des Instruments .......................... 8
Panneau Avant ...............................................................9
1. Interrupteur d’Alimentation ............................................ 9
2. Contrôle de Threshold ................................................... 9
3. Contrôle de Ratio ........................................................... 9
4. Contrôle d’Attack ........................................................... 9
5. Contrôle de Release .................................................... 10
6. Contrôle de Blend ........................................................ 10
7. Commutateur Voice ..................................................... 10
8. Commutateur Comp. ................................................... 10
9. Commutateur de Compteur VU .................................. 10
10. Vu-Mètre .................................................................... 10
11. Garniture du Compteur .............................................. 10
12. Contrôle de Master Output ........................................ 10
Panneau Arrière ............................................................ 11
1. Commutateur de Niveau E/S .......................................11
2. Entrées Symétriques ....................................................11
3. Sortie Symétriques .......................................................11
4. Connecteur d’Alimentation IEC .................................... 11
Specications - English ................................................12
Specications - Français ..............................................12
Block Diagram ..............................................................13
Warranty / Service - English ......................................... 14
La Garantie/L’Entretien - Français ................................15
Rear Page ....................................................................16
SOLO VLA
SOLO VLA
MULTIVOICE TUBE/OPTO COMPRESSOR
Table of Contents
2
Introduction
Thank you for purchasing Applied Research and Technology’s Solo VLA. Whether it’s to fatten up an
instrument take, smooth out a vocal performance or prevent clipping while laying down tracks, the ART
Solo VLA will elevate your projects to the next Level. The Solo VLA has lots of sound shaping options,
these options will help you create a signature sound that is right for you.
Parallel Compression
The Blend control is used to dial in dry signal back into the output. This allows the mix in some of the original
signal while using a heavy amount of compression to fatten up a track while retaining some of the dynamics.
Soft-Knee Leveling
The Solo VLA is a soft-knee leveling amplier by design. Although capable of providing dramatic com-
pression effects, the Solo VLA was designed to excel in applications where transparent, expressively
musical dynamics control is desired.
MultiVoice
Select between a pristine solid-state path or a class-A vacuum tube gain stage for warmer saturation.
Comprehensive Metering
A back-lit analog VU Meter can accurately display either the Output Level or Gain Reduction.
The Solo VLA’s impressive feature set
Mastering Quality Audio Signal Path
Selectable MultiVoice Tube/Solid State Control
Parallel Compression Blend Control
Hand selected 12AT7 Tube
OPTO - Analog Optical Isolators (AOI)
Non-VCA Design = transparent, classic sound
Backlit VU Meter: Output Level monitoring. Gain Reducing-Compression
Balanced XLR and 1/4-inch Inputs and Outputs
Variable Threshold and Ratio Controls
Variable Attack and Release Controls
Variable Blend (uncompressed and compressed signals)
Switch Selectable Level Modes; Pro (+4dBu)/Consumer (-10dBV)
20Hz to 80KHz Frequency Response (+0db+/-1dB)
>100dB (20-20k Hz) Dynamic Range
1U Rack-Mount Aluminum Front Plate
Removeable IEC Cord
Internal Power Supply
3-year parts and labor warranty
SOLO VLA
SOLO VLA
MULTIVOICE TUBE/OPTO COMPRESSOR
ACTIVE
GAIN
REDUCTION
OPTO
OUTPUT
BYPASS
FET
COMP.VOICE
APPLIED RESEARCH AND TECHNOLOGY
VU METER
-6 -2 12 25 0.3 0.6
DRY COMP1.25:1 20:1
dB mSEC SEC
-30 +20 0.25 50 0.15 3.0
BLENDTHRESHOLD RATIO ATTACK
dB
+15
-
MASTER OUTPUT
-5 +5
POWER3:1
RELEASE
I/O
LEVEL
+4 dBu
+4 dBu
-10 dBV
-10 dBV
INPUTOUTPUTA.R.T. SOLO VLA
A.R.T. SOLO VLA
BALANCED INPUT & OUTPUTS
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S. SERIAL NUMBER
DESIGNED BY YORKVILLE SOUND
TORONTO, CANADA
SOLOVLA A-ART-SOLO-VLA / 1v3
FUSE:
T0.5A 250V
AVERTISSEMENT - POUR RÉDUIRE
LE RISQUE D'INCENDIE OU
D'ÉLECTROCUTION, NE PAS
EXPOSER ET APPAREIL
À LA PLUIE OU À L'HUMIDITÉ
WARNING - TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE
THIS EQUIPMENT TO RAIN
OR MOISTURE
MODEL 112
AC INPUT:
100-120/240V
50/60Hz 25W
3
Installation
The ART Solo VLA may be used in a wide variety of applications and environments. In a rack-mountable, all-steel enclo-
sure, the unit is designed for continuous professional use. Mounting location is not critical, however for greater perfor-
mance reliability we recommend that you not place the unit on top of power amps, or other sources of heat and/or strong
magnetic elds. The tube circuitry needs about a minute to “warm up” and stabilize from a cold power up.
AC Power Hookup
The Solo VLA has an internal power supply designed to operate from 100-120V/220-240V~, 50/60Hz 25W. Units manu-
factured for use outside of North America have been modied to comply with the required electrical specications. Under
no circumstances should the power cable be altered. If the cable becomes cut or damaged, discontinue its use and have it
replaced before operating the Solo VLA.
The power source must provide a good ground connection, and the ground pin on the mains plug should never be defeated.
Audio Connections
Audio connections to and from the Solo VLA are:
Unbalanced 1/4-inch cables may be used with no damage to the Solo VLA. We recommend using only high-quality
cables equipped with the appropriate connectors.
Applications
Compressor/ Limiter
The main application of the Solo VLA is to control the dynamic range of an audio signal. Plug a line level (post preampli-
er or other gain stage) source into the Input, and set the Threshold and Output controls to provide the desired amount of
compression to the input signal.
Vocal and Instrument Leveling
The musical nature of the Solo VLA makes it ideal for use on a wide range of instruments and vocals. Place the Solo VLA into
a channel insert, after a preamplier, or in line with the direct output of a mixer channel. Adjust the controls of the Solo VLA to
achieve the desired amount of compression.
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S.
4
1 “Pumping” in a Compressor/Limiter sounds like the signal is muted when it shouldn’t be.
SOLO VLA
SOLO VLA
MULTIVOICE TUBE/OPTO COMPRESSOR
ACTIVE
GAIN
REDUCTION
OPTO
OUTPUT
BYPASS
FET
COMP.VOICE
APPLIED RESEARCH AND TECHNOLOGY
VU METER
-6 -2 12 25 0.3 0.6
DRY COMP1.25:1 20:1
dB mSEC SEC
-30 +20 0.25 50 0.15 3.0
BLENDTHRESHOLD RATIO ATTACK
dB
+15
-
MASTER OUTPUT
-5 +5
POWER3:1
RELEASE
Front Panel
1. Power Switch
The Power switch turns the power on and off to the unit. The Solo VLA should be turned “on” with all monitor levels turned down to pro-
tect against any “thumping” caused by power up. Likewise, the Solo VLA should be turned “off” after turning all monitor Levels down.
When the Power switch is turned on, the VU Meters will light. Switch LED’s will light if its associated switch is in the “in”
position. Power on the Solo VLA before any monitoring outputs or power amps are turned on.
Like all tube-based equipment, the Solo VLA needs to warm up to operating temperature. The 12AT7 tube will reach operating
temperature within one to three minutes. During this warm-up period you may experience sound variations due to the bias of
the tubes stabilizing. This is normal and the Solo VLA will provide consistent results once the warm-up period is over.
If the Solo VLA fails to power up when the Power switch is turned on, check to see that its power cord is plugged
into an active outlet. Locate the fuse installed in the IEC connecter, verify that the fuse is not blown, replace if blown
with the same type and value fuse. If the unit still fails to operate properly, turn it off and unplug it. Then consult your
dealer or the ART Customer Service Department.
2. Threshold Control
The Input Threshold control sets the point at which the Solo VLA will act on a signal. Turning this control counter-clock-
wise lowers the Threshold (adding more compression to a signal). Turning this control clockwise raises the Threshold.
Proper setting of the Input Threshold control is dependent on the input signal. The output of a guitar can be –20dB to
–10dB, whereas the level from an insert on a mixing console can be –10dB to +15dB. The easiest way to set the Input
Threshold control is to start with the control fully clockwise. Set the VU Meter to display Gain Reduction. Slowly turn
the control counter-clockwise (lowering the threshold) until the Gain Reduction VU Meter displays -5dB. Next adjust the
control (either lower or higher) for the desired amount of compression. Use the Gain Reduction Meter as a visual guide
to the amount of compression applied.
3. Ratio Control
The Ratio Control selects the “amount” of Compression applied to the input signal once that signal reaches or exceeds the
threshold. This compression amount is expressed as a ratio of input to output. For example, if a 4:1 compression ratio is
chosen, for every 4dB over the threshold the input signal rises, the output level only rises by 1dB. In this case if the input
signal increased 12dB over the threshold, the output level would only rise by 3dB.
In general, compression ratios of 10:1 and greater are considered “limiting”. The range of the Ratio control is (1.25:1) to
(20:1). The Solo VLA may be used as either a compressor or a limiter with all of the following:
- Multi track recorder, DAT machine, hard disk recorder, or analog recorder.
- In a mixers channel insert points.
- Between a microphone preamp and signal processors.
- Between pre-amplied electronic musical instruments (synthesizers, guitars, bass, samplers, acoustic instruments
with pickups) and other line-level equipment.
4. Attack Control
The Attack control sets the time it takes the Compressor/Limiter to respond to increases in signal Level (by reducing gain).
You can use this control to shape the “front end” of the dynamic’s envelope. One example is to listen to a snare hit and
adjust the Attack control. A short Attack makes the snare sound “thin.” As the attack time goes longer (the knob is turned
clockwise) you should hear more of the thump in the compressed snare. The downside is that this creates an overshoot,
(or “transient”), the length of which is the time set by the Attack control.
Overshoots less than 1 msec. are very hard to hear even when they are clipped. If the Attack is set too fast, the gain
may be reduced too much and thereby create a “pumping” sound. 1
89
1612
11
102
7
543
5
5. Release Control
The Release control sets the time the Compressor/Limiter takes to increase the gain after the input level drops.
Longer settings maintain the dynamics of the input signal, while shorter settings reduce the dynamics. Shorter settings
will also increase the apparent reverberation, and at extreme gain reduction settings, lead to “breathing” artifacts. 2
6. Blend Control
The Blend control mixes the dry and compressed signals. This allows you to use a heavy amount of compression to fatten
up a track and then mix in some of the original signal to retain some of the dynamics.
7. Voice Switch
Opto/FET
Switches the signal between the Solid-State FET based compressor and the opto compressor tube gain stage to
add a warmer saturation to the signal.
8. Comp. Switch
Bypass/Active
The Bypass switch bypasses all Compressor controls and passes the input signal to the output. This only works
when the system is Powered ON.
9. VU Meter Switch
Gain Reduction/Output
The Gain Reduction or Output Level of the Solo VLA can be monitored by selecting the function you want displayed on the VU Meter.
10. VU Meter
The Gain Reduction or Output Level of the Solo VLA can be monitored by the analog VU Meter. The VU Meter switch selects the
source of the audio for this meter. The ballistic characteristics of the meter provides an accurate indication of the average signal Level.
In Gain Reduction Mode, the meter sits at 0 VU unless the Compressor requires gain reduction. As gain reduction
increases the meter pointer drops to the below zero scale. The below zero scale indicates the dB of gain reduction.
In Output mode, the markings of the meter read the dB output level. 0 VU indicates that the output level is +4dBu
(1.228V RMS) when the output level switch is set to +4dBu and -10dBV (0.316V RMS) when set to -10dBV.
11. Meter Trim
The Meter Trim is used to adjust the Meter’s “0” point. This may change if the unit is NOT mounted with the front panel
perpendicular to the oor.
Using a small at-blade screwdriver you can mechanically ne-tune the meter indicator position if, for example, it does
not rest at the leftmost position when the unit is OFF.
12. Master Output Control
The output signal level at the rear output jacks is adjusted by this control. It can provide from +15dB of gain (fully clockwise).
2 “Breathing” is the sound of the Compressor/Limiter turning up the gain so quickly you can hear breathing noises between
words during vocal processing.
6
Rear Panel
1. I/O Level Switch
The Solo VLA can be optimized for either “professional” (+4dBu) or “consumer” (-10dBV) I/O levels. When the
switch is depressed, the unit is in “professional” Levels mode. This does not change the overall Gain of the unit, but
the operating Levels within the unit.
2. Balanced Inputs
The Solo VLA provides both an XLR and 1/4-inch input jack, both jacks are balanced. The 1/4-inch jack can be used with
unbalanced signals by simply plugging in an unbalanced cable.
The Inputs are designed for use with line level signals ranging from –30dBm to +20dBm. While it is possible to plug an
instrument directly into the Solo VLA, it is desirable to run the instrument into a preamp ahead of the Solo VLA. This will
provide a stronger signal and will keep noise to a minimum. Microphones must connect through a microphone preamplier
(like the ART Solo MPA) before connecting into the Solo VLA. The input impedance of the input 10K ohms.
3. Balanced Output
The output of the Solo VLA is available on both the 1/4-inch TRS and the XLR jacks. This output is active balanced. The
output has a 47 ohm impedance into a balanced or unbalanced load.
The analog VU Meter monitors the level present at this output. “0” VU on the analog VU Meter corresponds to +4dBu
(about 1.23 Volts RMS).
4. IEC Power Connector
This is a fused variable voltage selectable IEC connector. The fuse drawer can be removed for fuse replacement and used
to set for the correct incoming voltage 100-120V or 220-240V. Rotate the fuse drawer so that the arrow from the drawer
lines up with the IEC block for the mains voltage.
I/O
LEVEL
+4 dBu
+4 dBu
-10 dBV
-10 dBV
INPUTOUTPUTA.R.T. SOLO VLA
A.R.T. SOLO VLA
BALANCED INPUT & OUTPUTS
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S. SERIAL NUMBER
DESIGNED BY YORKVILLE SOUND
TORONTO, CANADA
SOLOVLA A-ART-SOLO-VLA / 1v3
FUSE:
T0.5A 250V
AVERTISSEMENT - POUR RÉDUIRE
LE RISQUE D'INCENDIE OU
D'ÉLECTROCUTION, NE PAS
EXPOSER ET APPAREIL
À LA PLUIE OU À L'HUMIDITÉ
WARNING - TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE
THIS EQUIPMENT TO RAIN
OR MOISTURE
MODEL 112
AC INPUT:
100-120/240V
50/60Hz 25W
1243
7
Introduction
Merci d’avoir acheté le Solo VLA d’Applied Research and Technology. Qu’il s’agisse d’étoffer une prise
d’instrument, d’adoucir une performance vocale ou d’éviter l’écrétage lors de la création de pistes, l’ART
Solo VLA élèvera vos projets au niveau supérieur. Le Solo VLA propose de nombreuses options de
mise en forme du son, ces options vous aideront à créer une signature sonore qui vous convient.
Compression Parallèle
La commande Blend est utilisée pour réintégrer le signal sec dans la sortie. Cela permet de mélanger
une partie du signal original tout en utilisant une forte compression pour grossir une piste tout en con-
servant une partie de la dynamique.
Nivellement Soft Knee
Le Solo VLA est un amplicateur de niveau soft-genou de par sa conception. Bien que capable de
fournir des effets de compression spectaculaires, le Solo VLA a été conçu pour exceller dans les appli-
cations où un contrôle transparent et expressif de la dynamique musicale est souhaité.
MultiVoix
Choisissez entre un chemin à semi-conducteurs vierge ou un étage de gain à tube de classe A pour une
saturation plus chaude.
Mesure Complète
Un VU-mètre analogique rétroéclairé peut afcher avec précision soit le niveau de sortie, soit la réduction de gain.
LEnsemble Impressionnant des Fonctionnalités du Solo VLA
Maîtriser le chemin du signal audio de qualité
Contrôle multivoix sélectionnable du tube/de l’état solide
Contrôle du mélange de compression parallèle
Tube 12AT7 sélectionné à la main
OPTO - Isolateurs optiques analogiques (AOI)
Conception non VCA = son transparent et classique
VU-mètre rétroéclairé : surveillance du niveau de sortie, réduction de gain et compression
Entrées et sorties XLR symétriques et 1/4 de pouce
Contrôles de Threshold et de Ratio variables
Contrôles d’attaque et de relâchement variables
Mélange variable (signaux non compressés et compressés)
Changer les modes de niveau sélectionnables ; Pro (+4dBu)/Consommateur (-10dBV)
Réponse en fréquence de 20 Hz à 80 kHz (+0 dB +/-1 dB)
Plage dynamique > 100 dB (20-20 kHz)
Plaque avant en aluminium pour montage en rack 1U
Cordon IEC amovible
Alimentation interne
Garantie de 3 ans pièces et main dœuvre
SOLO VLA
SOLO VLA
MULTIVOICE TUBE/OPTO COMPRESSOR
ACTIVE
GAIN
REDUCTION
OPTO
OUTPUT
BYPASS
FET
COMP.VOICE
APPLIED RESEARCH AND TECHNOLOGY
VU METER
-6 -2 12 25 0.3 0.6
DRY COMP1.25:1 20:1
dB mSEC SEC
-30 +20 0.25 50 0.15 3.0
BLENDTHRESHOLD RATIO ATTACK
dB
+15
-
MASTER OUTPUT
-5 +5
POWER3:1
RELEASE
I/O
LEVEL
+4 dBu
+4 dBu
-10 dBV
-10 dBV
INPUTOUTPUTA.R.T. SOLO VLA
A.R.T. SOLO VLA
BALANCED INPUT & OUTPUTS
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S. SERIAL NUMBER
DESIGNED BY YORKVILLE SOUND
TORONTO, CANADA
SOLOVLA A-ART-SOLO-VLA / 1v3
FUSE:
T0.5A 250V
AVERTISSEMENT - POUR RÉDUIRE
LE RISQUE D'INCENDIE OU
D'ÉLECTROCUTION, NE PAS
EXPOSER ET APPAREIL
À LA PLUIE OU À L'HUMIDITÉ
WARNING - TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE
THIS EQUIPMENT TO RAIN
OR MOISTURE
MODEL 112
AC INPUT:
100-120/240V
50/60Hz 25W
8
Installation
L’ART Solo VLA peut être utilisé dans une grande variété d’applications et d’environnements. Dans un boîtier tout en acier
montable en rack, l’unité est conçue pour une utilisation professionnelle continue. L’emplacement de montage n’est pas
critique, mais pour une plus grande abilité des performances, nous vous recommandons de ne pas placer l’unité au-
dessus d’amplicateurs de puissance ou d’autres sources de chaleur et/ou de champs magnétiques puissants. Le circuit
du tube a besoin d’environ une minute pour se « réchauffer » et se stabiliser après une mise sous tension à froid.
Branchement de l’Alimentation CA
Le Solo VLA dispose d’une alimentation interne conçue pour fonctionner à partir de 100-120 V/220-240 V~, 50/60 Hz 25
W. Les unités fabriquées pour être utilisées à l’extérieur de l’Amérique du Nord ont été modiées pour se conformer aux
spécications électriques requises. Le câble d’alimentation ne doit en aucun cas être modié. Si le câble est coupé ou
endommagé, cessez de l’utiliser et faites-le remplacer avant d’utiliser le Solo VLA.
La source d’alimentation doit fournir une bonne connexion à la terre et la broche de terre de la fiche secteur ne
doit jamais être défaite.
Connexions Audio
Les connexions audios d’entrée et de sortie de le Solo VLA sont :
Des câbles asymétriques de 1/4 de pouce peuvent être utilisés sans endommager le Solo
VLA. Nous vous recommandons d’utiliser uniquement des câbles de haute qualité équipés des
connecteurs appropriés.
Applications
Compresseur / Limiteur
L’application principale du Solo VLA est de contrôler la plage dynamique d’un signal audio. Branchez une source de
niveau ligne (post-préamplicateur ou autre étage de gain) dans l’entrée et réglez les commandes de Threshold et de sor-
tie pour fournir le niveau de compression souhaité au signal d’entrée.
Nivellement des Voix et des Instruments
La nature musicale du Solo VLA le rend idéal pour une utilisation sur une large gamme d’instruments et de voix. Placez le
Solo VLA dans un insert de canal, après un préamplicateur ou en ligne avec la sortie directe d’un canal de mixage. Ajustez
les commandes du Solo VLA pour obtenir le niveau de compression souhaité.
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S.
9
1 Le « pompage » dans un compresseur/limiteur donne l’impression que le signal est coupé alors qu’il ne devrait pas l’être.
SOLO VLA
SOLO VLA
MULTIVOICE TUBE/OPTO COMPRESSOR
ACTIVE
GAIN
REDUCTION
OPTO
OUTPUT
BYPASS
FET
COMP.VOICE
APPLIED RESEARCH AND TECHNOLOGY
VU METER
-6 -2 12 25 0.3 0.6
DRY COMP1.25:1 20:1
dB mSEC SEC
-30 +20 0.25 50 0.15 3.0
BLENDTHRESHOLD RATIO ATTACK
dB
+15
-
MASTER OUTPUT
-5 +5
POWER3:1
RELEASE
Panneau Avant
1. Interrupteur d’Alimentation
L’interrupteur d’alimentation allume et éteint l’appareil. Le Solo VLA doit être allumé avec tous les niveaux de contrôle
baissés pour se protéger contre tout « bruit sourd » provoqué par la mise sous tension. De même, le Solo VLA doit être
éteint après avoir baissé tous les niveaux du moniteur.
Lorsque l’interrupteur d’alimentation est allumé, les VU-mètres s’allument. Les LED du commutateur s’allumeront
si le commutateur associé est en position « in ». Allumez le Solo VLA avant d’allumer les sorties de contrôle ou les
amplificateurs de puissance.
Comme tous les équipements à tubes, le Solo VLA doit se réchauffer jusqu’à la température de fonctionnement. Le tube 12AT7
atteindra sa température de fonctionnement en une à trois minutes. Pendant cette période d’échauffement, vous pouvez
ressentir des variations sonores dues à la polarisation des tubes qui se stabilisent. Ceci est normal et le Solo VLA fournira des
résultats cohérents une fois la période d’échauffement terminée.
Si le Solo VLA ne parvient pas à s’allumer lorsque l’interrupteur d’alimentation est allumé, vériez que son cordon
d’alimentation est branché sur une prise active. Localisez le fusible installé dans le connecteur CEI, vériez que le fusible
n’est pas grillé, remplacez-le s’il est grillé par un fusible du même type et de même valeur. Si l’appareil ne fonctionne tou-
jours pas correctement, éteignez-le et débranchez-le. Consultez ensuite votre revendeur ou le service clientèle ART.
2. Contrôle de Threshold
La commande Input Threshold dénit le point auquel le Solo VLA agira sur un signal. Tourner cette commande dans le
sens inverse des aiguilles d’une montre abaisse le seuil (en ajoutant plus de compression au signal). Tourner cette com-
mande dans le sens des aiguilles d’une montre augmente le seuil.
Le réglage correct de la commande de seuil d’entrée dépend du signal d’entrée. La sortie d’une guitare peut aller de –20
dB à –10 dB, tandis que le niveau d’un insert sur une console de mixage peut aller de –10 dB à +15 dB. La manière la
plus simple de régler le contrôle du seuil d’entrée est de commencer avec le contrôle à fond dans le sens des aiguilles
d’une montre. Réglez le VU-mètre pour afcher la réduction de gain. Tournez lentement la commande dans le sens
inverse des aiguilles d’une montre (en abaissant le seuil) jusqu’à ce que le VU-mètre de réduction de gain afche -5 dB.
Ajustez ensuite la commande (soit inférieure, soit supérieure) pour obtenir le niveau de compression souhaité. Utilisez
l’indicateur de réduction de gain comme guide visuel de la quantité de compression appliquée.
3. Contrôle de Ratio
Le contrôle de ratio sélectionne la « quantité » de compression appliquée au signal d’entrée une fois que ce signal at-
teint ou dépasse le seuil. Ce montant de compression est exprimé sous forme de rapport entrée/sortie. Par exemple,
si un taux de compression de 4:1 est choisi, pour chaque 4 dB au-dessus du seuil, le signal d’entrée augmente, le
niveau de sortie n’augmente que de 1 dB. Dans ce cas, si le signal d’entrée augmentait de 12 dB au-dessus du seuil,
le niveau de sortie n’augmenterait que de 3 dB.
En général, les taux de compression de 10:1 et plus sont considérés comme « limitants ». La plage de la commande Ratio
est de (1,25:1) à (20:1). Le Solo VLA peut être utilisé comme compresseur ou limiteur avec tous les éléments suivants :
- Enregistreur multipiste, machine DAT, enregistreur sur disque dur ou enregistreur analogique.
- Dans le canal d’un mixeur, insérez des points.
- Entre un préampli micro et des processeurs de signal.
- Entre les instruments de musique électroniques pré-ampliés (synthétiseurs, guitares, basses, samplers,
instruments acoustiques avec micros) et autres équipements de niveau ligne.
4. Contrôle dAttack
La commande Attack dénit le temps nécessaire au compresseur/limiteur pour répondre aux augmentations du niveau
du signal (en réduisant le gain). Vous pouvez utiliser cette commande pour façonner le « front-end » de l’enveloppe de la
dynamique. Un exemple consiste à écouter un coup de caisse claire et à ajuster le contrôle d’attaque. Une attaque courte
89
1612
11
102
7
543
10
rend la caisse claire « ne ». À mesure que le temps d’attaque s’allonge (le bouton est tourné dans le sens des aiguilles
d’une montre), vous devriez entendre davantage de bruit sourd dans la caisse claire compressée. L’inconvénient est que
cela crée un dépassement (ou « transitoire ») dont la durée correspond au temps déni par la commande Attack.
Dépassements inférieurs à 1 ms. sont très diciles à entendre même lorsqu’ils sont
écrêtés. Si l’attaque est réglée trop rapidement, le gain peut être trop réduit et ainsi créer un
son de « pompage ». 1
5. Contrôle de Release
La commande Release définit le temps nécessaire au compresseur/limiteur pour augmenter le gain après la
baisse du niveau d’entrée.
Des réglages plus longs maintiennent la dynamique du signal d’entrée, tandis que des réglages
plus courts réduisent la dynamique. Des réglages plus courts augmenteront également la
réverbération apparente et, avec des réglages de réduction de gain extrêmes, entraîneront des
artefacts de « respiration ». 2
6. Contrôle de Blend
La commande Blend mélange les signaux secs et compressés. Cela vous permet d’utiliser une forte quantité de compres-
sion pour grossir une piste, puis de mélanger une partie du signal d’origine pour conserver une partie de la dynamique.
7. Commutateur Voice
Opto/FET
Commute le signal entre le compresseur basé sur le FET à semi-conducteurs et l’étage de gain du tube du com-
presseur opto pour ajouter une saturation plus chaude au signal.
8. Commutateur Comp.
Bypass/Active
Le commutateur Bypass contourne toutes les commandes du compresseur et transmet le signal d’entrée à la sortie.
Cela ne fonctionne que lorsque le système est sous tension.
9. Commutateur de Compteur VU
Gain Réduction/Sortie
La réduction de gain ou le niveau de sortie du Solo VLA peut être surveillé en sélectionnant la fonction que vous souhaitez afcher
sur le VU-mètre.
10. Vu-Mètre
La réduction de gain ou le niveau de sortie du Solo VLA peut être surveillé par le VU-mètre analogique. Le commutateur VU Meter
sélectionne la source de l’audio pour ce compteur. Les caractéristiques balistiques du compteur fournissent une indication précise du
niveau moyen du signal.
En mode de réduction de gain, l’indicateur de niveau se situe à 0 VU, sauf si le compresseur
nécessite une réduction de gain. À mesure que la réduction de gain augmente, l’indicateur du
compteur descend jusqu’à l’échelle inférieure à zéro. L’échelle inférieure à zéro indique le dB
de réduction de gain.
En mode Sortie, les marquages du compteur indiquent le niveau de sortie en dB. 0 VU indique
que le niveau de sortie est de +4 dBu (1,228 V RMS) lorsque le commutateur de niveau de sortie
est réglé sur +4 dBu et de -10 dBV (0,316 V RMS) lorsqu’il est réglé sur -10 dBV.
11. Garniture du Compteur
Le Meter Trim est utilisé pour ajuster le point « 0 » du Meter. Cela peut changer si l’unité n’est PAS montée avec le pan-
neau avant perpendiculaire au sol.
À l’aide d’un petit tournevis à lame plate, vous pouvez aner mécaniquement la position
de l’indicateur du compteur si, par exemple, il ne repose pas à la position la plus à gauche
lorsque l’appareil est éteint.
12. Contrôle de Master Output
Le niveau du signal de sortie aux prises de sortie arrière est ajusté par cette commande. Il peut fournir jusqu’à +15 dB de
gain (à fond dans le sens des aiguilles d’une montre).
2 « Breathing » est le son du compresseur/limiteur qui augmente le gain si rapidement que vous pouvez entendre des bruits de
respiration entre les mots pendant le traitement vocal.words during vocal processing.
11
Panneau Arrière
1. Commutateur de Niveau E/S
Le Solo VLA peut être optimisé pour les niveaux d’E/S « professionnels » (+4 dBu) ou « grand public » (-10 dBV).
Lorsque le commutateur est enfoncé, l’appareil est en mode Niveaux « professionnels ». Cela ne modifie pas le
gain global de l’unité, mais les niveaux de fonctionnement au sein de l’unité.
2. Entrées Symétriques
Le Solo VLA fournit à la fois une prise d’entrée XLR et 1/4 de pouce, les deux prises sont symétriques. La prise jack 1/4
de pouce peut être utilisée avec des signaux asymétriques en branchant simplement un câble asymétrique.
Les entrées sont conçues pour être utilisées avec des signaux de niveau ligne allant de –30 dBm à +20 dBm. Bien qu’il
soit possible de brancher un instrument directement sur le Solo VLA, il est souhaitable de faire passer l’instrument dans
un préampli avant le Solo VLA. Cela fournira un signal plus fort et réduira le bruit au minimum. Les microphones doivent
être connectés via un préamplicateur de microphone (comme l’ART Solo MPA) avant de se connecter au Solo VLA.
L’impédance d’entrée de l’entrée 10K ohms.
3. Sortie Symétriques
La sortie du Solo VLA est disponible sur les prises TRS 1/4 de pouce et XLR. Cette sortie est active symétrique. La sortie
a une impédance de 47 ohms dans une charge équilibrée ou déséquilibrée.
Le VU-mètre analogique surveille le niveau présent à cette sortie. « 0 » VU sur le VU-mètre analogique correspond à
+4dBu (environ 1,23 Volts RMS).
4. Connecteur d’Alimentation IEC
Il s’agit d’un connecteur IEC sélectionnable à tension variable avec fusible. Le tiroir à fusibles peut être retiré pour le rem-
placement des fusibles et utilisé pour régler la tension entrante correcte 100-120V ou 220-240V. Faites pivoter le tiroir à
fusibles de sorte que la èche du tiroir s’aligne avec le bloc IEC pour la tension secteur.
I/O
LEVEL
+4 dBu
+4 dBu
-10 dBV
-10 dBV
INPUTOUTPUTA.R.T. SOLO VLA
A.R.T. SOLO VLA
BALANCED INPUT & OUTPUTS
CONNECTIONS XLR
PIN 1 = GROUND
PIN 2 = (+
+
) HOT
PIN 3 = (
-
) COLD
TIP = (+
+
) HOT
RING = (
-
) COLD
SLEEVE = GROUND
INPUT
OUTPUT
1/4-INCH T.R.S. SERIAL NUMBER
DESIGNED BY YORKVILLE SOUND
TORONTO, CANADA
SOLOVLA A-ART-SOLO-VLA / 1v3
FUSE:
T0.5A 250V
AVERTISSEMENT - POUR RÉDUIRE
LE RISQUE D'INCENDIE OU
D'ÉLECTROCUTION, NE PAS
EXPOSER ET APPAREIL
À LA PLUIE OU À L'HUMIDITÉ
WARNING - TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE
THIS EQUIPMENT TO RAIN
OR MOISTURE
MODEL 112
AC INPUT:
100-120/240V
50/60Hz 25W
1243
12
Impédance d'entrée 10K ohms entrée de ligne
Output Impedance47 ohms sortie de ligne
Bruit d'entrée équivalent
(
EIN
)
Mode +4dBu-99 dBu (A-pondéré)
Mode -10dBv -107 dBu (A-pondéré)
Niveaux maximum
Commutateur d'Entrées et Sorties+4 dBu / -10 dBV sélectionnable
Entrées+25 dBu (en mode +4 dBu) / +16 dBV (mode -10 dBV)
Sorties +25 dBu
Gain de sortie +15 dB entrée de ligne
Réponse en Fréquence20 Hz à 80 kHz (+0 / -1 dB)
Pla
g
e d
y
namique >100 dB (20 - 20 kHz)
THD
@
0dBm Out <0,02 % (typical)
Temps d'attaque 0,25 ms à 50 ms variable
Temps de rétablissement 150 ms à 3 sec variable
Compression Ratio
(
Slope
)
Variable : 1,25 : 1 à 20 : 1
Atténuation maximale 30 dB
Exi
g
ences d'alimentation 100-120V 60Hz / 220-240V 50Hz
Dimensions 1,75 pouces x 19 pouces x 6,0 pouces
4,45 cm x 48,3 cm x 15,2 cm
Poids5,6 livres. / 2,5 kg
`
Caractéristiques Techniques
ART maintient une politique d'amélioration constante des produits. ART se réserve le droit d'apporter des
modifications à la conception ou d'apporter des ajouts ou des améliorations à ce produit sans aucune obligation
de l'installer sur des produits précédemment fabriqués. Par conséquent, les spécifications peuvent être modifiées
sans préavis.
Input Impedance10k ohms Line In
Output Impedance47 ohms Line Out
Equivalent Input Noise
(
EIN
)
+4dBu mode -99dBu ('A' weighted)
-10dBv mode -107dBu ('A' weighted)
Maximum Levels
Range Switch +4dBu/-10dBv selectable
Inputs +25dBu (in +4dBu mode) / +16dBV ( –10dBV mode)
Output +25dBu
Output Gain +15dB Line In
Frequenc
y
Response 20Hz to 80kHz (+ 0/-1dB)
D
y
namic Ran
g
e >100dB (20-20kHz)
THD
@
0dBm Out <0.02% (typical)
Attack Time 0.25msec. to 50msec. variable
Release Time 150msec. to 3sec. variable
Compression Ratio
(
Slope
)
Variable: 1.25:1 to 20:1
Maximum Attenuation 30dB
Power Requirements 100-120V 60Hz / 220-240V 50Hz
Dimensions
(
HWD
)
1.75-inch x 19-inch x 6.0-inch
4.45 cm x 48.3 cm x 15.2 cm
Wei
g
ht 5.6 lb / 2.5 kg
`
Specifications
ART maintains a policy of constant product improvement. ART reserves the right to make changes in design, or
make additions to, or improvements upon, this product without any obligation to install same on products
previously manufactured. Therefore, specifications are subject to change without notice.
Specications - Français
Specications - English
13
ART Solo VLA
Block Diagram
Block-Diagram-ART-SOLOVLA-00-1v1
Optical
Stage
O/P
Gain Stage
Balanced
XLR Input
(REAR PANEL)
Balanced
TRS 1/4-inch Input
(REAR PANEL)
Balanced
XLR Output
(REAR PANEL)
Balanced
TRS 1/4-inch Output
(REAR PANEL)
MASTER
OUTPUT LEVEL
Analog VU Meter
JFET
Tube Stage
OPTO/JFET
BYPASS
RELEASETHRESHOLD
ATTACK RATIO
Detector
Stage
COMPRESSOR
+4dBu
I/O LEVEL
-10dBV
+4dBu
I/O LEVEL
-10dBV
VU
80
60
40
20
0
100%
20
10
3
3
5
5
7
+
-
2
1
0
1
OUTPUT
LEVEL
GAIN
RERDUCTION
BLEND
Blend
Block Diagram
14
Doc-ART-WARRANTY-SERVICE-00-1v1.doc ENGLISH August 18, 2022
WARRANTY INFORMATION
Limited Warranty
Applied Research and Technology will provide warranty and service for this unit in accordance with the following warrants:
Applied Research and Technology, (A R T) warrants to the original purchaser that this product and the components
thereof will be free from defects in workmanship and materials for a period of three years from the date of purchase. Ap-
plied Research and Technology will, without charge, repair or replace, at its option, defective product or component parts
upon prepaid delivery to the factory service department or authorized service center, accompanied by proof of purchase
date in the form of a valid sales receipt.
Exclusions
This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or
repairs. This warranty is void if the serial number is altered, defaced, or removed.
A R T reserves the right to make changes in design or make additions to or improvements upon this product without any
obligation to install the same on products previously manufactured.
A R T shall not be liable for any consequential damages, including without limitation damages resulting from loss of use.
Some states do not allow limitations of incidental or consequential damages, so the above limitation or exclusion may not
apply to you. This warranty gives you specific rights and you may have other rights, which vary from state to state.
For units purchased outside the United States, an authorized distributor of Applied Research and Technology will provide service
Fill in the following information for your reference:
Date of purchase ___________________
Purchased from ___________________
SERVICE
The following information is provided in the unlikely event that your unit requires service.
1. Be sure that the unit is the cause of the problem. Check to make sure the unit has power, all cables are connected
correctly, and the cables themselves are in working condition. You may want to consult with your dealer for assistance
in troubleshooting or testing your particular configuration.
2. If you believe that the ART unit is at fault, go to www.artproaudio.com.
3. Select “Support”, then “Return Authorization Requestto request a return authorization number.
4. If you are returning the unit for service, pack the unit in its original carton or a reasonable substitute. The original packaging
may not be suitable as a shipping carton, so consider putting the packaged unit in another box for shipping. Print the RA
number clearly on the outside of the shipping box. Print your return shipping address on the outside of the box.
5. Include, with your unit, a note with the RA number and your contact information, including a return shipping address
(we cannot ship to a P.O. box) and a daytime phone number, and a description of the problem, preferably attached to
the top of the unit. Also include a copy of your purchase receipt.
Warranty / Service - English
15
FRANÇAIS
INFORMATION SUR LA GARANTIE
Garantie Limitée
Applied Research and Technology fournira une garantie et un service pour cet appareil conformément aux garanties suivantes:
Applied Research and Technology, (A R T) garantit à l'acheteur initial que ce produit et ses composants seront exempts
de défauts de fabrication et de matériaux pendant une période de trois ans à compter de la date d'achat. Applied Re-
search and Technology réparera ou remplacera, sans frais, à sa discrétion, le produit ou les composants défectueux sur
livraison prépayée au service après-vente de l'usine ou au centre de service agréé, accompagnée d'une preuve de la
date d'achat sous la forme d'un reçu de vente valide.
Exclusions
Cette garantie ne s'applique pas en cas de mauvaise utilisation ou d'abus du produit ou à la suite de modifications ou de
réparations non autorisées. Cette garantie est nulle si le numéro de série est altéré, défiguré ou retiré.
A R T se réserve le droit d'apporter des modifications à la conception ou d'apporter des ajouts ou des améliorations à ce
produit sans aucune obligation de l'installer sur des produits fabriqués précédemment.
A R T ne sera pas responsable des dommages consécutifs ou indirects, y compris, sans limitation, les dommages résul-
tant de la perte d'utilisation. Certains États n'autorisent pas l'exclusion ou la limitation de responsabilité pour les dom-
mages consécutifs ou indirects, la restriction ci-dessus peut donc ne pas être applicable dans votre cas. Cette garantie
vous donne des droits spécifiques et vous pouvez avoir d'autres droits, qui varient d'un état à l'autre.
Pour les unités achetées en dehors des États-Unis, un distributeur agréé d'Applied Research and Technology fournira le service.
Remplissez les informations suivantes pour votre référence :
Date d'achat ___________________
Acheté chez ___________________
SERVICE
Les informations suivantes sont fournies dans le cas improbable où votre appareil pourrait nécessiter un entretien.
1. Assurez-vous que l'appareil est bien à l'origine du problème. Vérifiez que l'appareil est sous tension, que tous les
câbles sont correctement connectés et que les câbles eux-mêmes sont en bon état de fonctionnement. Vous pouvez
consulter votre revendeur pour obtenir de l'aide afin de dépanner ou de tester votre configuration particulière.
2. Si vous pensez que l'unité ART est en cause, rendez-vous sur www.artproaudio.com.
3. Sélectionnez " Support ", puis " Return Authorization Request " pour demander un numéro d'autorisation de retour.
4. Si vous retournez l'appareil pour réparation, emballez le dans son carton d'origine ou dans un substitut raisonnable. Il
se peut que l'emballage d'origine ne convienne pas comme carton d'expédition, envisagez donc de mettre l'appareil
emballé dans une autre boîte pour l'expédition. Imprimez clairement le numéro d'autorisation de retour sur l'extérieur
de la boîte d'expédition. Imprimez votre adresse de retour sur l'extérieur de la boîte.
5. Joignez à votre appareil une note indiquant le numéro d'autorisation de retour et vos coordonnées, y compris une
adresse de retour (nous ne pouvons pas expédier à un casier postal) et un numéro de téléphone ou vous pouvez être
rejoint durant la journée, ainsi qu'une description du problème, de préférence fixée sur le dessus de l'appareil. Joi-
gnez également une copie de votre facture d'achat.
La Garantie/L’Entretien - Français
www.artproaudio.com
©2023 Applied Research & Technology / Yorkville Sound
APPLIED RESEARCH AND TECHNOLOGY
Manual-Owners-ART-SOLOVLA-00-1v1 • January 11, 2024
Solo VLA
MultiVoice TUBE / OPTO Compressor
112-5004-100
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Art Pro Audio SOLO VLA Manuale del proprietario

Tipo
Manuale del proprietario