Panasonic WHMHF12G6E5 Manuale del proprietario

Tipo
Manuale del proprietario

Questo manuale è adatto anche per

Português Nederlands Italiano Deutsch Español Français English
F569818
Operating Instructions
(Mono bloc)
Air-to-Water Heatpump
Operating Instructions
(Mono bloc) Air-to-Water Heatpump
2-15
Installation Instructions attached.
Mode d’emploi
Pompe à chaleur air-eau (Mono bloc)
16-29
Consignes d’installation jointes.
Instrucciones de funcionamiento
Bomba de calor de aire a agua (Mono bloc)
30-43
Instrucciones de instalación adjuntas.
Bedienungsanleitung
(Kompaktgerät) Luft/Wasser-Wärmepumpe
44-57
Installationsanleitung liegt bei.
Istruzioni operative
Pompa di calore Aria-acqua (Mono bloc)
58-71
Istruzioni per l’installazione allegate.
Gebruiksaanwijzing
(Mono bloc) Air-to-Water Warmtepomp
72-85
De instructies voor installatie zijn bijgevoegd.
Instruções de funcionamento
Bomba de Calor Ar-Água (Mono bloco)
86-99
Instruções de instalação anexadas.
Model No.
Mono bloc Unit
WH-MHF09G3E5
WH-MHF12G6E5
2
Thank you for purchasing Panasonic
product.
Before operating the system, read these
operating instructions thoroughly and keep them
for future reference.
Table of contents
Safety precautions ……………………………3-5
To adjust initial settings ………………………6-7
How to use ………………………………… 8-12
Maintenance …………………………………… 12
Troubleshooting ……………………………13-14
Information …………………………………… 15
Air-to-Water
Heatpump
(mono-bloc unit)
Power Supply
Solar Panel
Radiator
Shower
Fan Coil Unit
Floor
Heating
Water Tank Unit
Remote Control
Before use, make sure the system
has been installed correctly by an
authorised dealer according to the
given instructions.
Panasonic (Mono bloc) Air-to-Water Heatpump is designed to
operate with Panasonic Water Tank Unit. Unless used together
with the Panasonic Water Tank Unit, Panasonic does not
guarantee any normal operation nor the reliability of the system.
• These operating instructions describe how to operate the system
using the mono bloc unit.
• As for the operation of other products such as water tank,
radiator, external thermo controller, and underfloor units, refer to
the operating instructions of each product.
• Some functions described in this manual may not be applicable
to your system.
• Consult your nearest authorised dealer for further information.
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Operating conditions
HEATING
Water outlet temperature (°C)
(Min. / Max.)
25 / 65
Outdoor ambient temperature (°C)
(Min. / Max.)
-20 / 35
When the outdoor temperature is out of the
range in the table, the heating capacity will drop
significantly and the mono bloc unit may stop
operating for its protection.
The unit will restart automatically after the outdoor
temperature returns to the specified range.
System overview
3
To prevent personal injury, injury to
others or property damage, please
comply with the following:
Incorrect operation due to failure to
follow instructions below may cause
harm or damage, the seriousness of
which is classified as below:
WARNING
This sign warns of
death or serious
injury.
CAUTION
This sign warns of
injury or damage
to property.
The instructions to be followed are
classified by the following symbols:
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions COMPULSORY.
WARNING
Mono bloc unit
This appliance may be used by
children aged from 8 years and
above and persons with reduced
physical, sensory or mental
capabilities or lack of experience
and knowledge if they have been
given supervision or instruction
concerning use of the appliance
in a safe way and understand
the hazards involved. Children
shall not play with the appliance.
Cleaning and user maintenance
shall not be made by children
without supervision.
Please consult an authorised
dealer or specialist to clean the
internal parts, repair, install,
remove and reinstall the unit.
Improper installation and
handling will cause leakage,
electric shock or fire.
Confirm with an authorised
dealer or specialist on usage of
any specified refrigerant type.
Using refrigerant type other than
the specified may cause product
damage, burst and injury etc.
Do not install the unit in
a potentially explosive or
flammable atmosphere. Failure
to do so could result in fire.
Do not insert your fingers
or other objects into the
mono bloc unit; the rotating
parts may cause injury.
Safety precautions
EnglishSafety precautions
4
Do not touch the mono bloc unit
during lightning, it may cause an
electric shock.
Do not sit or step on the
unit, you may fall down
accidentally.
Power supply
Do not use a
modified cord, joint
cord, extension
cord or unspecified
cord to prevent
overheating and fire.
To prevent overheating, fire or
electric shock:
Do not share the same power
outlet with other equipment.
Do not operate with wet hands.
Do not bend or twist power
supply cord.
If the supply cord is damaged,
it must be replaced by the
manufacturer, service agent or
similarly qualified persons in
order to avoid a hazard.
This unit is equipped with
Residue Current Circuit Breaker
(RCCB). Ask an authorised
dealer to check RCCB operation
regularly, especially after
installation, inspection, and
maintenance. RCCB malfunction
may result in electric shock and/
or fire.
It is strongly recommended that
Install Residual Current Device
(RCD) on-site to prevent electric
shock and/or fire.
Before obtaining access to
terminals, all supply circuits must
be disconnected.
Stop using the product if any
abnormality/failure occurs and
disconnect the power supply.
(Risk of smoke/fire/electric
shock)
Examples of abnormality/failure
RCCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of
the unit is observed.
Hot water leaks from the unit.
Contact your local dealer
immediately for maintenance/
repair.
Wear gloves during inspection
and maintenance.
This equipment must be earthed
to prevent electrical shock or fire.
Prevent electric shock by
disconnecting the power supply
before cleaning or servicing.
This appliance is for multiple
uses. To avoid electric shock,
burn and/or fatal injury, make
sure to disconnect all power
supplies before accessing any
terminal in the unit.
Safety precautions
5
CAUTION
Mono bloc unit
Do not wash the unit with water,
benzine, thinner or scouring
powder to avoid damage or
corrosion on the unit.
Do not install the unit close
to any combustibles or at
bathroom. Otherwise, it may
cause electric shock and/or fire.
Do not touch the water discharge
pipe of the unit during operation.
Do not place any material on the
unit or under it.
Do not touch the sharp
aluminium fin; sharp parts
may cause injury.
Do not use the system during
sterilisation in order to prevent
scalding with hot water, or
overheating of shower.
Prevent water leakage by
ensuring that the drainage pipe
is connected properly.
After a long period of use, make
sure the installation rack is not
deteriorated. The deteriorated
rack may cause the unit to fall
down.
Ask an authorised dealer
to determine the level of
sterilisation function field settings
according to the local laws and
regulations.
Remote control
Do not wet the remote control.
Failure to do so may result in
electric shock and/or fire.
Do not press the buttons on the
remote control using hard and
sharp objects. Failure to do so
may cause damage to the unit.
Do not wash the remote control
using water, benzine, thinner or
scouring powder.
Do not inspect or maintain the
remote control by yourself.
Consult an authorised dealer in
order to prevent personal injury
caused by incorrect operation.
EnglishSafety precautions
6
To adjust initial settings
Dealer
Select menus and determine settings according to the system available in the
household. It is recommended that all alterations of settings are done by an
authorised dealer or specialist.
• After initial installation, you may manually adjust the settings.
The initial setting remains active until the user changes it.
• The remote control can be used for multiple installations.
• Ensure the operation LED is OFF before setting.
• The system may not work properly if set wrongly. Please consult
an authorised dealer.
1
Press and simultaneously and hold for
5 seconds until the display shows SETTING STATUS.
2
Press
or to select the menu.
3
Press
to enter the menu.
4
Press or to select YES/NO, or other options.
YES: to enable the menu
NO: to disable the menu
5
Press
to confirm.
Remote Control
DisplayOperation LED
Menu (1 ~ 17)
Default
Setting
Setting Display
1
Room Thermostat Connection
To select whether or not to connect to the optional room
thermostat.
NO YES NO
2
Backup Heater Selection
To reduce the heater power if unnecessary.
*Options of kW vary depending on the model.
9 kW
*3 kW / 6 kW /
9 kW
3
Water System Freeze Prevention
To activate or deactivate the water freeze prevention when the
system is OFF.
YES YES NO
4
Tank Connection
To select whether or not to connect to the optional water tank unit.
Note: If NO is selected, menus 5 to 15 are skipped.
NO YES NO
5
Solar Priority
To select the use of solar panel for heating up the water tank.
NO YES NO
6
Heating Priority
To select the room heating as priority during HEAT + TANK mode.
Note: If YES is selected, menus 7 and 8 are skipped for HEAT +
TANK mode.
NO YES NO
7
Heating Operation Interval
To set the interval for HEAT mode during HEAT + TANK mode.
Note: If YES is selected in menu 6, this menu is skipped.
3 hours
0.5 hours ~
10 hours
8
Tank Heat-up Interval
To set the interval for the water tank during HEAT + TANK mode.
Note: If YES is selected in menu 6, this menu is skipped.
30 minutes
5 minutes ~
1 hour 35 minutes
7
9
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 10 is skipped.
YES YES NO
10
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is
heating up the water tank.
1 hour
20 minutes ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
11
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 12 to 14 are skipped.
YES YES NO
12
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~ Sunday
0:00 ~ 23:50
13
Sterilisation Temperature
To set the temperature of sterilisation.
70 °C 40 °C ~ 75 °C
14
Continuation of Sterilisation
To maintain heating temperature in order to complete the
sterilisation.
10 minutes
5 minutes ~
1 hour
15
Base Pan Heater
To select whether or not to connect to the optional base pan
heater.
Note: If NO is selected, menu 16 is skipped.
NO YES NO
16
Base Pan Heater type
Type A - The base pan heater activates only during deice
operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
AAB
17
Dry Concrete
During construction to dry the concrete under a preset
temperature.
Do not use this menu for any other purposes and in period other
than during construction (Refer to information page).
- 1 day ~ 99 days
User
Remote control preparation
1
Press
.
2
Press
or to set the current day.
3
Press to confirm.
4
Repeat steps
2
and
3
to set the current time.
Note:
The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
EnglishTo adjust initial settings
8
How to use
User
Enjoy quiet operation
Press .
• This operation reduces the noise of mono bloc unit.
The operation may cause heating ability to decrease.
User
System status check mode
1
Press
.
(The display shows STATUS.)
2
Press or to check the selected mode.
• Dry concrete (does not show during normal
operation)
• The Water Inlet Temperature
• Tank Temperature
• Compressor Running Frequency
• Error History
Heat mode total power consumption (Up to 999 days)
Tank mode total power consumption (Up to 999 days)
• Press to exit the STATUS mode.
Note:
• Once the STATUS mode is entered, the display
shows STATUS.
• The STATUS mode cannot be activated when the
display shows SETTING.
• The total power consumption is an estimated value
based on AC 230 V and may differ from value
measured by precise equipment.
Note: In normal operation, the , and buttons are not in use.
User
Turn on or off the system
Press .
When the system is ON, the operation LED is lit and the
actual water outlet temperature and outdoor ambient
temperature are shown on the display.
User
Select operation mode
Press to select operation mode.
HEAT
The panel/floor HEAT operation is either
turned ON or OFF.
• The mono bloc unit provides heat to the
system.
HEAT
+ TANK
• The mono bloc unit provides heat to the
sanitary water tank and the system.
• This mode can be selected only when the
sanitary water tank is installed.
TANK • The sanitary water tank is either turned
ON or OFF.
• The mono bloc unit provides heat to the
sanitary water tank.
User
Initiate the backup heater
Press
.
• The backup heater provides extra heat at low outdoor
temperature. The backup heater is possible only in the
heat mode.
• Once the backup heater is set, it is automatically
operated when conditions are fulfilled.
• To disable the backup heater, press
again.
The system is turned off by an external switch.
9
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
Dealer
System temperature setting
Temperature setting Display
The system controls the temperature for each menu based on the
outdoor ambient temperature.
• To set or change the temperatures, make sure to contact your
nearest authorised dealer.
1
Press and hold for 5 seconds to enter the
temperature range setting mode.
(The display shows SETTING.)
2
Press
or to select a menu.
3
Press to enter the menu.
4
Press or to set the desired temperature.
5
Press
to confirm the setting.
• Repeat steps
2
to
5
to set other menus.
User
Checking the temperature range
1
Press and hold
for 5 seconds to enter the temperature range setting mode.
2
Press
or to select a menu.
• Press
to exit.
Menu
Default
setting
Temperature
setting
Display
Setting of low outdoor ambient temperature. -5 °C -15 °C ~ 15 °C
HEAT
Setting of high outdoor ambient temperature. 15 °C -15 °C ~ 15 °C
Setting of water outlet temperature at low outdoor
ambient temperature.
55 °C 25 °C ~ 65 °C
Setting of water outlet temperature at high outdoor
ambient temperature.
35 °C 25 °C ~ 65 °C
During HEAT mode, the water
outlet temperature is adjusted as
is shown the diagram on the right.
It is performed within the preset
temperature range.
<Water outlet
temperature>
<Outdoor ambient temperature>
max. water temp.
min. water temp.
Setting of outdoor ambient temperature to turn
OFF heating operation during HEAT mode.
24 °C 5 °C ~ 35 °C
HEAT
Setting of outdoor ambient temperature to turn ON
the backup heater.
0 °C -15 °C ~ 20 °C
HEATER
Setting of sanitary water tank temperature. 52 °C 40 °C ~ 75 °C
TANK
EnglishHow to use
10
How to use
User
Shifting the water temperature
Desired temperature setting
This easily shifts the water outlet temperature if the setting is
undesirable.
1
Press
to enter the water temperature shifting mode.
2
Press
to change setting.
3
Press
or to set the desired temperature.
(temperature range: -5 °C ~ 5 °C)
Temperature setting
+5
-5
Shift value
<Water outlet
temperature>
<Outdoor ambient temperature>
4
Press to confirm the setting.
Note:
• Press or wait for 30 seconds to exit the SETTING mode.
• The set temperature will be saved in the system once confirmed.
• The SETTING mode cannot be activated when the SERVICE and STATUS indicators are ON.
• The system will shift the temperature within water outlet temperature range.
User
Holiday mode
• By setting the day (s) in holiday mode, it promotes energy saving
while you are on holiday, and enables the system to resume at the
preset temperature after your holiday.
• Ensure that the system is OFF before setting.
• The system will resume operation automatically at 00:00 am after
the holiday.
• The day the HOLIDAY mode was set is counted as day 1.
Desired days
Example:
Setting the holiday mode on June 21, 08:00 am. By setting 3 days,
the system resumes operation on June 24, 00:00 am.
1
Press
to enter the HOLIDAY mode.
2
Press
or to set the desired days.
(Setting range: 1 day ~ 999 days)
3
Press to confirm the setting.
Note:
• Press or wait 30 seconds to exit the HOLIDAY mode.
11
User
Weekly timer setting
Promotes energy saving by allowing you to set up to 6
programmes in any given day.
Indicates the next timer operation
programme
Day to be selected
Indicates the next timer
operation day
Programme number in a day
OFF Timer
ON Timer
Lights up if Timer operation is selected
1
Press
to enter the timer setting mode.
2
Press
or to select your desired day.
3
Press to confirm your selection.
4
“1” will be blinking, press
to set
programme 1.
5
Press
to select ON or OFF timer.
6
Press or to select your desired time.
You can set , , and the Water
Temperature Thermo Shift setting.
7
Press
to confirm programme 1. The selected
day will be highlighted with .
• After 2 seconds, the display will move to the next
programme. Repeat steps
4
to
7
to set
programmes 2 to 6.
• During timer setup, if no button is pressed within
30 seconds, or if the
is pressed, the setting at
that moment is confirmed and timer setup is ended.
To check current timer programme
1
Press to enter timer mode and press
to enter day setting.
2
Press
or until your desired day is shown,
press to confirm your selection.
3
Press
or to check the set programmes.
To modify current timer programme
or add new timer programme
1
Perform steps
1
to
7
of “Weekly timer
setting” to modify existing timer programme, or
add any timer programme.
To cancel current timer programme
1
Press to enter day.
2
Press
or until your desired day is shown,
press to enter programme setting.
3
Press
or until your desired programme is
shown.
Press to cancel the programme and will
disappear.
To disable/enable Weekly Timer
To disable weekly timer setting, press , then
press .
To enable previous weekly timer setting, press ,
then press .
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
EnglishHow to use
12
Mono bloc Unit
In case of a power supply failure or pump operating failure, drain the system (as suggested in the figure below).
H
<H
When water is idle inside the system, freezing up is very likely to happen which could
damage the system.
• Do not obstruct the air inlet and air outlet vents, it may cause low performance or
breakdown. Please remove obstacles to assure the ventilation.
• During winter, please clean and remove the snow near mono bloc unit so that the snow
does not cover the air inlet and air outlet vents.
External filter
• Clean the external filter at least once a year. Failure to do so may cause the filter to clog up, which may lead to system
breakdown. Consult an authorised dealer.
Inspection
• In order to ensure optimal performance of the units,
seasonal inspections on the units, external filter and field
wiring have to be carried out at regular intervals. Consult
an authorised dealer about maintenance.
• Clear any obstruction on the air inlet and outlet vents of
the mono bloc unit.
For extended non-use
• Do not switch off the power supply. Switching off the
power supply will stop the automatic water pump
operation and will cause jamming in the water pump.
Non serviceable criteria
Disconnect the power supply
then please consult an authorised dealer under the
following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
Maintenance
Weekly timer setting
Note:
• You may set the timer for each day of the week (Monday to Sunday) with 6 programmes per day.
• When the system is switched on by the timer, it will use the previously set temperature to control the water outlet
temperature.
• The same timer programme cannot be set on the same day.
• You may also select 2 or more days with the same timer setting.
How to use
13
The following symptoms do not indicate malfunction.
Symptom Cause
Water flowing sound during operation. • Refrigerant flow inside the unit.
Operation is delayed a few minutes
after restarting.
• The delay is a protection for the compressor.
Mono bloc unit emits water/steam. • Condensation or evaporation occurring in the pipes.
Steam comes out of the mono bloc
unit in the heating mode.
• It is caused by defrost operation in the heat exchanger.
Mono bloc unit does not operate. • It is caused by the protection control of the system when outdoor temperature is
out of the operating range.
System operation switches off. • It is caused by the protection control of the system. When the water inlet
temperature is lower than 10 °C, the compressor stops and the backup heater
power turns on.
System is hard to heat up. • When the panel and the floor are heated simultaneously, warm water temperature
may decrease, which may reduce the heating ability of the system.
• When the outdoor air temperature is low, the system may need longer time to heat
up.
• Discharge outlet or intake inlet in the mono bloc unit is blocked by some obstacle,
such as a pile of snow.
• When the preset water outlet temperature is low, the system may need longer time
to heat up.
System does not heat up instantly. • System will take some time to heat up the water if it starts to operate at cold water
temperature.
Backup heater is automatically turned
ON when it is disabled.
• It is caused by the protection control of the unit heat exchanger.
Operation starts automatically when the
timer is not set.
• Sterilisation timer has been set.
Display power consumption remains
as previous value.
• Memory is saved on hourly basis. If a power failure occurs, the data kept from last
hour will be displayed.
• Total power consumption has reached 999 days. Press
to reset the counter.
HEAT indicator blinks on the display. • System is performing deice operation.
Loud refrigerant noise continue for a
few minutes.
• It is caused by protection control during deice operation at outdoor ambient
temperature lower than -10°C.
Check the following before calling for servicing.
Symptom Check
Operation in HEAT mode is not
working efficiently.
• Set the temperature correctly.
• Close the panel heater valve.
• Clear any obstruction in the air inlet and air outlet vents of the mono bloc unit.
Noisy during operation. • Mono bloc unit has been installed at an incline.
• Close the cover properly.
System does not work. • Circuit breaker has tripped/activated.
Operation LED is not lit or nothing is
displayed on the remote control.
• Check that the power supply is working correctly, or that a power failure has not
occurred.
Troubleshooting
Force Heater Mode Button
• If a malfunction occurs in the system, the backup heater may be used to heat up the water.
Press to switch on the backup heater.
• Press
to switch off the backup heater.
• In the Force Heater mode, no other operation can be used.
• This feature is only available to certain error codes.
• Refer to dealer for more details.
EnglishHow to use / Maintenance / Troubleshooting
14
Troubleshooting
The operation LED blinks and error code appears on
the display.
• Disconnect the power supply, and report
the error code to an authorised dealer.
• The timer operation will be cancelled
when an error code is displayed.
Diagnostic
display
Abnormality or Protection
control works
H12
Capacity mismatch
H15
Abnormal compressor temperature
sensor
H20
Abnormal water pump
H23
Abnormal refrigerant 1 sensor
H27
Abnormal service valve
H42
Compressor low pressure protection
H62
Abnormal water flow
H63
Abnormal low pressure sensor
H64
Abnormal high pressure sensor
H65
Abnormal deice water circulation
H70
Abnormal back-up heater overload
protector
H72
Abnormal tank temperature sensor
H76
Remote control communication error
H90
Abnormal indoor / outdoor
communication
H91
Abnormal tank heater overload protector
H95
Abnormal voltage connection
H98
Outdoor high pressure protection
H99
Indoor heat exchanger freeze prevention
Diagnostic
display
Abnormality or Protection
control works
F12
Pressure switch activated
F14
Poor compressor rotation
F15
Abnormal outdoor fan motor lock
F16
Comprehensive current protection
F20
Compressor temperature overload
protection
F22
Transistor module temperature overload
protection
F23
DC peak abnormal of operation
F24
Abnormal Refrigerant cycle
F25
Abnormal in a
c
ooling / heating charge
F27
Abnormal pressure switch
F30
Abnormal water outlet sensor 2
F36
Abnormal outdoor air temperature
sensor
F37
Abnormal water inlet sensor
F40
Abnormal outdoor discharge sensor
F41
Abnormal power factor correction
F42
Abnormal outdoor heat exchanger
sensor
F43
Abnormal outdoor defrost sensor
F45
Abnormal water outlet sensor
F46
Abnormalities in outdoor current
transformer disconnection
F48
Abnormal evaporator outlet temperature
sensor
F49
Abnormal bypass outlet temperature
sensor
F95
Abnormal cooling high pressure
15
Information
Dry Concrete Function
• During construction to dry the concrete under a preset temperature.
1
Press
and simultaneously and hold for 5 seconds until the display shows “ ”.
2
Press
.
(The display shows “ ”.)
3
Press
to select day.
Press
or to set the desired temperature.
4
Press to confirm the selection.
5
Repeat step
3
and
4
to set other days and temperature.
• Press to exit.
Operation/settings to be done only by the authorised dealer/specialist.
To Reset the Remote Control to Default
Setting
1
Press , , continuously for 5 seconds. The
operation is off during this period.
2
The display shows “
, , ” for 2
seconds for confirmation. After 2 seconds, it goes to
normal display.
Information for Users on Collection and Disposal of Old Equipment
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and
electronic products should not be mixed with general household waste.
For proper treatment, recovery and recycling of old products, please take them to applicable collection points,
in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products correctly, you will help to save valuable resources and prevent any potential
negative effects on human health and the environment which could otherwise arise from inappropriate waste
handling.
For more information about collection and recycling of old products, please contact your local municipality,
your waste disposal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further
information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your
local authorities or dealer and ask for the correct method of disposal.
EnglishTroubleshooting / Information
Nous vous remercions d’avoir porté
votre choix sur un produit Panasonic.
Avant d’utiliser le système, lisez ce mode
d’emploi dans son intégralité et conservez-le
pour toute référence ultérieure.
Table des matières
Consignes de sécurité ……………………17-19
Réglage initial ………………………………20-21
Consignes d’utilisation ……………………22-26
Entretien ……………………………………… 26
Dépannage …………………………………27-28
Informations …………………………………… 29
16
Avant utilisation, assurez-vous que le
système a été installé correctement par
un revendeur agréé conformément aux
instructions fournies.
Cette pompe à chaleur air-eau (mono bloc) Panasonic est
conçue pour fonctionner avec un réservoir d’eau Panasonic.
Si elle n’est pas utilisée avec un réservoir d’eau Panasonic, le
fonctionnement normal et la fiabilité du système ne sont pas
garantis par Panasonic.
• Ce mode d’emploi décrit comment utiliser le système avec l’unité
mono bloc.
• En ce qui concerne le fonctionnement d’autres produits, tels que
le réservoir d’eau, le radiateur, le contrôleur thermique externe
et les unités de chauffage au sol, consultez le mode d’emploi de
chaque produit.
• Il est possible que certaines fonctions décrites dans ce manuel
ne soient pas applicables à votre système.
• Consultez votre revendeur agréé le plus proche pour en savoir
plus.
Les illustrations de ce mode d’emploi sont fournies à titre d’exemple uniquement et peuvent présenter des différences
par rapport à l’appareil proprement dit.
Celles-ci peuvent être modifiées sans préavis à des fins d’amélioration.
Vue d'ensemble du système
Conditions d’utilisation
CHAUFFAGE
Température de sortie d’eau (°C)
(Min. / Max.)
25 / 65
Température ambiante extérieure (°C)
(Min. / Max.)
-20 / 35
Si la température extérieure sort de la plage
indiquée dans le tableau, la capacité thermique
chutera de façon importante et l’unité mono bloc
risque de s’arrêter pour sa propre protection.
L’unité redémarrera automatiquement une fois que
la température extérieure sera de nouveau dans la
plage spécifiée.
Panneau solaire
Radiateur
Douche
Ventilo-
convecteur
Chauffage
au sol
Réservoir d’eau
Pompe à chaleur
air-eau
(unité mono bloc)
Alimentation
Télécommande
17
Pour éviter des blessures corporelles
sur vous-même et sur les autres ou
des dégâts matériels, respectez les
instructions ci-dessous :
Tout dysfonctionnement dû au
non-respect des instructions peut
occasionner des nuisances ou des
dégâts dont la gravité est classée
comme décrit ci-après :
AVERTISSEMENT
Ce symbole
signale la
présence d’un
danger pouvant
provoquer des
blessures graves
ou mortelles.
ATTENTION
Ce symbole
signale la
présence d’un
danger pouvant
provoquer
des blessures
corporelles ou
des dégâts
matériels.
Les instructions à respecter sont
classées d’après les symboles
suivants :
Ce symbole désigne une
action INTERDITE.
Ces symboles
désignent des actions
OBLIGATOIRES.
AVERTISSEMENT
Unité mono bloc
Cet appareil peut être utilisé
par des enfants à partir de
8 ans et par des personnes aux
capacités physiques, sensorielles
ou mentales diminuées,
ou manquant d’expérience
ou de connaissances, si le
fonctionnement en toute sécurité
de l’appareil leur a été expliqué
et s’ils comprennent les dangers
impliqués. Les enfants ne doivent
pas jouer avec cet appareil. Le
nettoyage et l’entretien régulier
ne doivent pas être réalisés par
des enfants sans surveillance.
Veuillez consulter un revendeur
agréé ou un spécialiste pour le
nettoyage des pièces internes et
pour la réparation, l’installation,
le retrait et la réinstallation
de l’unité. Une installation et
une manipulation incorrectes
pourraient occasionner des fuites,
un choc électrique ou un incendie.
Validez auprès du revendeur
agréé ou du spécialiste l’usage
de tout type de réfrigérant
spécifié.
L’utilisation d’un type de
réfrigérant autre que celui
spécifié peut endommager
le produit ou provoquer des
explosions, des brûlures, etc.
N’installez pas l’appareil dans
une atmosphère potentiellement
explosive ou inflammable. Sinon,
il y a un risque d’incendie.
Consignes de sécurité
FrançaisConsignes de sécurité
18
N’insérez jamais vos doigts
ou des objets dans l’unité
mono bloc ; les parties
rotatives peuvent entraîner
des blessures.
Ne touchez pas l’unité mono
bloc au cours d’un orage, cela
pourrait provoquer un choc
électrique.
Ne vous asseyez pas et
ne montez pas sur l’unité,
vous risquez de tomber
accidentellement.
Alimentation
N’utilisez pas de
cordon modifié, de
raccords, de rallonge
ou de cordon non
spécifié afin d’éviter
une surchauffe et un
incendie.
Pour éviter une surchauffe, un
incendie ou un choc électrique :
Ne partagez pas la prise
d’alimentation avec un autre
appareil.
N’utilisez pas l’unité avec des
mains mouillées.
Ne pliez ou ne tordez pas le
cordon d’alimentation.
Si le cordon d’alimentation
est endommagé, il doit être
remplacé par le fabriquant, un de
ses techniciens ou une personne
qui possède des qualifications
équivalentes afin d’éviter tout
risque.
Cette unité est équipée
d’un disjoncteur de courant
résiduel (RCCB). Demandez
à un revendeur agréé de
vérifier régulièrement le
fonctionnement du RCCB,
surtout après l’installation,
l’inspection ou l’entretien. Un
dysfonctionnement du RCCB
peut provoquer un choc
électrique et/ou un incendie.
Il est fortement conseillé
d’installer un dispositif à courant
résiduel (DCR) sur le site afin
d’éviter un choc électrique et/ou
un incendie.
Tous les circuits d’alimentation
doivent être débranchés avant
tout accès aux bornes.
Arrêtez d’utiliser le produit en
cas d’anomalie/défaillance
et débranchez l’alimentation.
(Risque de fumée / feu / choc
électrique)
Exemples d’anomalie ou défaillance
Le RCCB se déclenche
souvent.
Vous remarquez une odeur de
brûlé.
Vous remarquez des bruits
anormaux ou des vibrations de
l’unité.
De l’eau chaude fuit de l’unité.
Contactez immédiatement votre
revendeur local pour l’entretien/
réparation.
Portez des gants pendant
l’inspection et l’entretien.
Cet équipement doit être
raccordé à la terre afin d’éviter un
choc électrique ou un incendie.
Consignes de sécurité
19
Évitez tout choc électrique en
débranchant l’alimentation avant
le nettoyage ou l’entretien.
Cet appareil convient à de
multiples usages. Pour éviter
tout choc électrique, toute
brûlure et/ou blessure mortelle,
assurez-vous d’avoir débranché
toutes les alimentations avant
d’accéder aux bornes de l’unité.
ATTENTION
Unité mono bloc
Ne lavez pas l’unité à l’eau,
au benzène, au diluant ou à la
poudre à récurer afin d’éviter
tout endommagement ou toute
corrosion de l’unité.
N’installez pas l’unité à proximité
de combustible ou dans une
salle de bains. Sinon, il existe un
risque de choc électrique et/ou
d’incendie.
Ne touchez pas le tuyau
d’évacuation d’eau de l’unité
pendant le fonctionnement.
Ne placez rien sur ou sous
l’unité.
Ne touchez pas l’ailette en
aluminium, car ses arêtes
vives peuvent causer des
blessures.
N’utilisez pas le système pendant
la stérilisation afin d’éviter toute
brûlure avec l’eau chaude ou la
surchauffe de la douche.
Empêchez toute fuite d’eau
en vous assurant que le tuyau
de vidange est correctement
raccordé.
Après une longue période
d’utilisation, assurez-vous que le
support d’installation n’est pas
détérioré. Un support détérioré
peut entraîner la chute de l’unité.
Demandez à un revendeur agréé
de déterminer le niveau des
réglages sur site de la fonction
de stérilisation conformément
aux lois et réglementations
locales.
Télécommande
Ne mouillez pas la
télécommande. Cela pourrait
provoquer un choc électrique et/
ou un incendie.
N’appuyez pas sur les touches
de la télécommande à l’aide
d’objets durs et pointus. Cela
pourrait endommager l’unité.
Ne nettoyez pas la
télécommande avec de l’eau,
du benzène, du diluant ou de la
poudre à récurer.
N’inspectez pas et n’entretenez
pas la télécommande vous-
même. Consultez un revendeur
agréé afin d’éviter toute blessure
due à un fonctionnement
incorrect.
FrançaisConsignes de sécurité
20
Réglage initial
Revendeur
Sélectionnez les menus et déterminez les réglages en fonction du système
disponible dans le foyer. Il est recommandé que toutes les modifications de
réglage soient réalisées par un revendeur agréé ou un spécialiste.
• Après l’installation initiale, vous pouvez ajuster les réglages
manuellement. Le réglage initial reste actif jusqu’à sa
modification par l’utilisateur.
• La télécommande peut être utilisée pour plusieurs installations.
• Assurez-vous que la DEL de fonctionnement est éteinte (OFF)
avant de réaliser le réglage.
• Le système peut ne pas fonctionner correctement s’il est mal
réglé. Veuillez consulter un revendeur agréé.
1
Appuyez sur et simultanément pendant 5 secondes,
jusqu'à ce que SETTING STATUS s'affiche à l'écran.
2
Appuyez sur
ou pour sélectionner le menu.
3
Appuyez sur pour entrer dans le menu.
4
Appuyez sur ou pour sélectionner YES/NO, ou
d’autres options.
YES : pour activer le menu
NO : pour désactiver le menu
5
Appuyez sur
pour valider.
Télécommande
AffichageDEL de fonctionnement
Menu (1 ~ 17)
Réglage
par défaut
Réglage Affichage
1
Raccordement du thermostat de la pièce
Pour sélectionner si le thermostat de la pièce en option est raccordé ou
non.
NO YES NO
2
Sélection du chauffage de secours
Pour réduire la puissance du chauffage, le cas échéant.
*Les valeurs en kW disponibles dépendent du modèle.
9 kW
*3 kW / 6 kW /
9 kW
3
Prévention du gel du circuit d'eau
Pour activer ou désactiver la prévention du gel du circuit d’eau lorsque le
système est à l’ARRÊT.
YES YES NO
4
Raccordement du réservoir
Pour sélectionner si le réservoir d’eau en option est raccordé ou non.
Remarque : Si NO est sélectionné, les menus 5 à 15 sont ignorés.
NO YES NO
5
Priorité au solaire
Pour sélectionner l’utilisation du panneau solaire pour le chauffage du
réservoir d’eau.
NO YES NO
6
Priorité au chauffage
Pour sélectionner le chauffage de la pièce comme priorité en mode
CHAUFFAGE + RÉSERVOIR.
Remarque : Si YES est sélectionné, les menus 7 et 8 sont ignorés pour le
mode CHAUFFAGE + RÉSERVOIR.
NO YES NO
7
Intervalle de fonctionnement du chauffage
Pour régler l’intervalle pour le mode CHAUFFAGE pendant le mode
CHAUFFAGE + RÉSERVOIR.
Remarque : Si YES est sélectionné dans le menu 6, ce menu est ignoré.
3 heures
0,5 heure ~
10 heures
8
Intervalle de chauffage du réservoir
Pour régler l’intervalle pour le réservoir d’eau pendant le mode
CHAUFFAGE + RÉSERVOIR.
Remarque : Si YES est sélectionné dans le menu 6, ce menu est ignoré.
30 minutes
5 minutes ~
1 heure 35 minutes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Panasonic WHMHF12G6E5 Manuale del proprietario

Tipo
Manuale del proprietario
Questo manuale è adatto anche per