MSH300, MSH301 Safety and installation instructions
11
Please observe the following instructions:
• When working on the following cables, only use insulated cable lugs, plugs and
flat push-on receptacles:
– 30 (direct supply from positive battery terminal)
– 15 (connected positive terminal, behind the battery)
– 31 (return cable from the battery, earth)
Do not use terminal strips.
• The safest type of connection is to solder the ends of the cables together and
then insulate them.
Only use insulated cable terminals, plugs and flat sockets for releasable
connections. Do not use crimp terminals (cable connectors) or terminal strips.
• Use a crimping tool (fig. 1 10, page 3) to connect the cables.
• When connecting to cable 31 (earth), screw the cable
– To the vehicle's earth bolt with a cable lug and a gear disc or
– To the sheet-metal bodywork with a cable lug and a self-tapping screw.
Ensure that there is a good earth connection.
If you disconnect the negative terminal of the battery, all data stored in the volatile
memories will be lost.
• The following data must be set again, depending on the vehicle equipment
options:
–Radio code
– Vehicle clock
–Timer
– On-board computer
– Seat position
You can find instructions for making these settings in the appropriate operating
instructions.
Observe the following installation instructions:
• Secure the parts installed in the vehicle in such a way that they cannot become
loose under any circumstances (sudden braking, accidents) and cause injuries
to the occupants of the vehicle.
• To prevent damage, when drilling ensure that there is sufficient space on the
other side for the drill head to come out (fig. 2, page 4).
• Deburr all drill holes and treat them with a rust-protection agent.
MSH300--IO-16s.book Seite 11 Donnerstag, 13. Juli 2017 10:28 10