Samsung AZ12PHHEA/MID Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente

Questo manuale è adatto anche per

ENGLISH
OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATION
MANUAL DE INSTRUÇÕES
ISTRUZIONI PER L'USO
Window-type Room Air Conditioner ( Cool and Heat )
Acondicionador de aire doméstico sistema de tipo ventana ( Refrigeración y Calefacción )
Climatiseur de type Fenêtre ( Refroidissement et Chauffage )
O ar Condicionado de Window-Type ( Refrigeração e Aquecimento )
Condizionatore d’aria per ambienti da finestra ( Raffreddamento e Riscaldamento )
E S F P I
DB98-22420A(1)
ESPAÑOL
FRANÇAIS
PORTUGUÊS
ITALIANO
AZ09PHHEA/EB
AZ12PHHEA/EB
E-2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their
own
discretion. Instead, they are requested to directly contact a designated
service
center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch
off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the
breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7
meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. Can cause injury or death. Disconnect all
remote
electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar
qualified
person in order to avoid a hazard.
AQ07S2GE IB_E_15110 04/2/2 15:35 Page 2
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Never store or ship the air conditioner upside down or sideways to avoid damage
to
the compressor.
The appliance is not intended for use by young children or infirm persons without
supervision:
Young children should be supervised to ensure that they do not play
with
the appliance.
Max current is measured according to IEC standard for safety and current is
measured
according to ISO standard for energy efficiency.
OTHERS
Before throwing out the device, it is necessary to pull back the battery cells and
get
rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectl
y, refrigerant may blow out and come into contact with your skin,causing
injur
y. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally
responsible manner.
D
ISPOSING OF THE UNIT
Register your product at www.samsung.com/global/register
Contents
PREPARING YOUR AIR CONDITIONER
Safety Precautions ......................................................................................... 2
Air Conditioning Unit - Main Parts, Buttons and Display ............................... 4
Remote Control Buttons ................................................................................. 5
Getting Started ............................................................................................... 6
Inserting the Remote Control Batteries .......................................................... 7
OPERATING YOUR AIR CONDITIONER
Cooling Your Room ........................................................................................ 8
Heating Your Room ........................................................................................ 9
Airing Your Room ........................................................................................... 10
Adjusting the Air Flow Direction Horizontally .................................................. 11
Adjusting the Air Flow Direction Vertically ...................................................... 11
PROGRAMMING YOUR AIR CONDITIONER
Setting the On Timer ...................................................................................... 12
Setting the Off Timer ...................................................................................... 13
Setting the Sleep Timer .................................................................................. 14
RECOMMENDATIONS FOR USE
Operating Recommendation ........................................................................... 15
Temperature and Humidity Ranges ................................................................ 16
Cleaning Your Air Conditioner ........................................................................ 17
Solving Common Problems ............................................................................ 18
Technical Specifications ................................................................................. 18
METHOD OF INSTALLATION .................................................................................... 19
E-
3
ENGLISH
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
The maximum permissible system impedance at the power junction box is 0.27 ohms.
Usually, the maximum permissible mains impedance will not be exceeded when the
branch to the power outlet is fed from a junction box with a rated current of 32A.
AZ18✴✴
" The high inrush current of the starting compressor motor can have adverse effects to
the operation of other equipment under unfavorable mains conditions. This equipment
does not comply with the relevant technical standards for the limitation of voltage
fluctuations and flicker."
Before connecting this equipment to the power supply system, please report to your
supply authority and obtain the consent.
Do not connect other electric appliances to the same supply lines.
E-4
Air Conditioning Unit - Main Parts, Buttons and Display
The design and shape are subject to
change according to the model.
Air inlet (Inside)
Ventilation lever
Air inlet (Outside
)
Outer air fl
ow blades
(up/d
own orientation)
Inner air fl
ow blades
(right/left orientation)
Temperature adjustment
buttons
Remote Control senso
r
Air fl
ow blade
swing button
Fan speed adjustment
button
On/O
ff button
Sleep timer setting
button
Timer setting button
Ope
rating mode selection
button (COOL,FAN,HEAT)
Power plug
The type of the power plug
may differ according to the
type of local power supply.
The power plug may be not supplied
depending on the model.
The air filter is
located in side
Air Outle
t
Timer indicator
Fan speed indicators
(LO
W, MED, HIGH)
Temperature/Timer
Operating mode indicators
(COOL, FAN, HEAT)
Air flow blade swing indicator
Deice indicator
Remote Control - Buttons
Temperature adjustment
buttons
Fan speed adjustment
buttons
ON/OFF button
E-
5
ENGLISH
Timer setting button
Sleep timer setting button
Operating mode
selection buttons
Air flow blade swing button
Getting Started
You have just purchased a window-type room air conditioner and it has been installed by your
installation specialist.
Your Owner’s Instructions contain valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit’s functions.
This Owner’s Instructions is just for using your air conditioner correctly.
Thus, the illustrations shown in this manual may not exactly match your air conditioners.
The booklet is organized as follows.
The following figures are shown on pages 4 and 5:
- Air conditioning unit (main parts, buttons and display)
- Remote control (buttons)
They will help you find the buttons and understand the symbols displayed.
In the main part of the document, you will find a series of step-by-step procedures for each
function available.
The illustrations in the step-by-step procedures use four different symbols:
Moreover, applicable, wherever the illustrations show the positions of the buttons on both the
remote control and the unit itself.
For the... The illustrations have a...
Remote control Gray background.
Example:
Unit itself White background.
Example:
PRESS PUSH IMPORTANT NOTE
E-
6
Inserting the Remote Control Batteries
You must insert or replace the remote control batteries when:
You purchase the air conditioner
The remote control does not work correctly
Use two AAA, LR03 1.5 V batteries. Do not use old
batteries or different kinds of batteries together.
Batteries may be completely discharged after 12 months,
even if they have not actually been used.
1 Push the battery cover on the rear of the remote control with your thumb in
the direction of the arrow and remove it.
2
Insert the two batteries, taking care to respect the polarities:
+ on the battery with + on the remote control
– on the battery with – on the remote control
3
Close the cover by sliding it back until it clicks into place.
Result
:
You can control all the functions on your air conditioning unit
directly from your seat, using the remote control.
E-
7
ENGLISH
You must select the Cool mode if you wish to lower the temperature in your
room.
You can also set the fan speed.
1 If necessary, press the (On/Off) button.
Result
: The operating mode indicator (COOL, FAN or HEAT) on
the
unit comes on.
The air conditioner starts up in the mode selected
when
the unit was last used.
The unit beeps twice.
The air conditioner is fitted with a protection mechanism to prevent
the
unit from being damaged when it is started immediately after
being:
Plugged in
Stopped
It
will start up automatically after about three minutes.
2
If the COOL indicator is not lit up on the unit:
Press the button on the remote control
or
Press the MODE button on the unit one or more times until the COOL
indicator
lights up
Result
: The unit beeps each time you press MODE.
The air conditioner starts up in Cool mode.
You can change modes at any time.
3
To adjust the temperature, press the or button on the remote
control
one or more times until the required temperature is displayed.
To adjust the temperature, press the or button on the unit one
or
more times until the required temperature is displayed.
Possible
temperatures are between 18°C and 30°C inclusive.
Result
: Each time you press the temperature buttons:
The temperature is adjusted by 1°C and
displayed
on the control panel
The unit beeps
The air conditioner starts cooling if the room temperature is
higher
than the selected temperature.
4
To set the fan speed to...
Then..
.
Result
: Each time you press a button, the unit beeps.
5
To control the direction of the air flow, refer to page 11.
Cooling Your Room
Remote Control
Control
Panel
High Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Med Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Low
Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
E-8
Heating Your Room
E-9
HSILGNE
You must select the Heat mode if you wish to heat your room to a specific
temperatu
re. You can also set the fan speed.
1 If necessary, press the (On/Off) button.
Result
: The operating mode indicator (COOL, FAN or HEAT) on
the
unit comes on.
The air conditioner starts up in the mode selected
when
the unit was last used.
The unit beeps twice.
The air conditioner is fitted with a protection mechanism to prevent
the
unit from being damaged when it is started immediately after
being:
Plugged in
Stopped
It
will start up automatically after about three minutes.
2
If the HEAT indicator is not lit up on the unit:
Press the button on the remote control
or
Press the MODE button on the unit one or more times until the HEAT
indicator
lights up
Result
: The unit beeps each time you press MODE.
The air conditioner starts up in Heat mode.
You can change modes at any time.
3
To adjust the temperature, press the or button on the remote
control
one or more times until the required temperature is displayed.
To adjust the temperature, press the or button on the unit one
or
more times until the required temperature is displayed.
Possible
temperatures are between 16°C and 30°C inclusive.
Result
: Each time you press the temperature buttons:
The temperature is adjusted by 1°C and
displayed
on the control panel
The unit beeps
The air conditioner starts heating if the room temperature is
lower
than the selected temperature.
4
To set the fan speed to...
Then..
.
Result
: Each time you press a button, the unit beeps.
5
To control the direction of the air flow, refer to page 11.
High Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Med Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Low
Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Remote Control
Control
Panel
Airing Your Room
E-10
If the atmosphere in your room is stale, you can air it using the Fan
feature
and if necessary, evacuate the stale air outside.
1
If you wish to evacuate stale air outside, push the ventilation lever on the front
of
the unit to the right and the open position ( ).
Result
:
The air inside the room circulates and stale air is evacuated outside.
Otherwise,
push the ventilation lever to the left and the closed position ( ).
Result
: The air simply circulates inside the room.
2
If necessary, press the (On/Off) button.
Result
: The operating mode indicator (COOL, FAN or HEAT) on the
unit
comes on.
The air conditioner starts up in the mode selected
when
the unit was last used.
The unit beeps twice.
3
If the FAN indicator is not lit up on the unit:
Press the button on the remote control
or
Press the MODE button on the unit one or more times until the FAN
indicator
lights up
Result
: The unit beeps each time you press MODE.
The air conditioner starts up in Fan mode.
You can change modes at any time.
When the air conditioner is in Fan mode, the
temperature
is not displayed; in this case, you do not
need
to set the temperature.
4
To set the fan speed to...
Then..
.
Result
: Each time you press a button, the unit beeps.
5
To control the direction of the air flow, refer to page 11.
High Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Med Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Low
Press the button on the remote control.
or
Press the on the unit until the
indica
tor lights up
Remote Control
Cont
rol Panel
Adjusting the Air Flow Direction Horizontally
E-11
HSILGNE
Depending on the position of the unit in your room, you can adjust the
orientation
of the inner air flow blades on the right-hand side of the
unit,
thus increasing the efficiency of the air conditioner.
1 Press the (or on the unit) button on the remote control.
Result
: The inner blades swing automatically left and right.
2
To stop the blades moving left and right, press the
(or on the unit)
button
on the remote control
.
To stop the blades in a specific position and orient the air flow in the
corresponding direction, simply press the
(or on the unit)
button
on the remote control
when the blades are in the desired position.
The blades may stop swinging momentarily when the Deice function is
ac
tivated (see page 15 for further details on this function.) They will start
swinging
again automatically as soon as the Deice function stops.
Again depending on the position of the unit in your room, you can
adjust
the orientation of the outer air flow blades on the right-hand
side
of the unit.
RECOMMENDATION When... Adjust the blades to face...
Coolin
g Upwards.
Heating Downwards.
Adjust
the air flow blades to the desired position, by pushing them upwards or
downwards.
If you orient the air flow blades downwards and the unit operates in Cool mode
for
a long period of time, dew may:
Form on the surface of the blades
Drip from the blades
Adjusting the Air Flow Direction Vertically
Remote Control Control Panel
Setting the On timer
E-12
The On Timer enables you to switch on the air conditioner automatically after
a given period time. You can set the period of time from 1 hour to 24 hours.
You can set the period of time from 1 hour to 24 hours.
You can select the On timer only when the air conditioner is off.
1 Check that the air conditioner has been switched off; if necessary,
press
the (On/Off) button.
3
Set the operating time by pressing:
Timer on the remote control.
or
Timer on the unit one or more times.
Possible time
is between 1 hour and 24 hour inclusive.
Result
: The remaining time is displayed and decreased by 1 hour
automatically
to indicate the remaining time.
The air conditioner switches on automatically when the
operating
time reaches zero.
You can change the setting mode, fan speed, and air flow direction
after
setting the On timer.
To Cancel the On Timer
2
Set the required mode by pressing the appropriate button:
, or on the remote control
Mode button on the unit (press it one or more times until the
appropriate
operating mode indicator lights up)
To cancel the On timer, press:
Timer on the remote control or unit one or more times until " " is
displayed.
or
on the remote control or unit (The air conditioner operates in the mode
selected
when the unit was last used.)
Setting the Off Timer
E-13
HSILGNE
The Off Timer enables you to switch off the air conditioner
automatically
after a given period of time.
You can set the period of time from 1 hour to 24 hours.
You can select the Off timer only when the air conditioner is on.
1 Check that the air conditioner has been switched on; if necessary,
press
the (On/Off) button.
2
Set the operating time by pressing:
Timer on the remote control
or
Timer on the unit one or more times.
Possible
times are between 1 hour and 24 hour inclusive.
Result: The remaining time is displayed and decreased by 1 hour
automatically
to indicate the remaining time.
The air conditioner switches off automatically when the
operating
time reaches zero.
You can change the setting mode, fan speed, and air flow direction
after
setting the Off timer.
To Cancel the Off Timer
To cancel the Off timer, press:
Timer on the remote control or unit one or more times until " " is
displayed.
or
on the remote control or unit (The air conditioner operates in the mode
selected
when the unit was last used.)
Remote Control
Control
Panel
Setting the Sleep timer
The Sleep Timer can be used when you are cooling or heating your
room
to switch the air conditioner off automatically after a period of
8 hours.
If you wish to switch the unit off at a specific time, refer to page 13.
1 Make sure that you have selected either COOL or HEAT mode.
2
Press the button on the remote control
or
Press the button on the unit until the SLEEP indicator lights up.
Result
: Each time you press a button, the unit beeps.
The “SLEEP” passes through the control panel for about
15
seconds and the " " will be displayed.
The remaining time is displayed and decreased by 1 hour
automatically
to indicate the remaining time.
The air conditioner will be controlled as illustrations below.
To cancel the timer, press:
on the remote control.
or
on the unit.
Result
: The unit beeps.
The SLEEP indicator is no longer displayed.
The air conditioner operates in the mode selected last.
To Cancel the Sleep Timer
E-14
Cooling When the temperature has
been
increased by 1°C (after
1 hour), it is maintained for 7
hours.
Heatin
g The temperature is decreased
by
1°C after 1 hour.
When
it has been decreased
by
2°C (after 2 hour), the
temperature
is maintained for
6 hours.
Set
TEMP.
Start
time
Stop
time
1hr 8hr
Remote Control
Control
Panel
E-
15
ENGLISH
Operating Recommendations
Here are a few recommendations that you should follow when using your air conditioner.
Heating performances The heat pump inside the air conditioner absorbs heat from outside air
and brings it indoors. If the temperature of the outside air drops, the air
conditioner will heat less. If you find that the room is not warm enough,
use an additional heating appliance.
Topic Recommendation
Warm air circulation The air conditioner circulates warm air to heat your room; as a result,
some time will be required after starting the air conditioner to warm the
entire room. If necessary, set the air conditioner going a short time
before you wish to use the room.
Frost When outside temperatures are low and humidity is high, frost may
form in the units condensor when heating with your air conditioner. If
this happens:
The unit stops heating
The air flow blades stop swinging
The Deice mode is triggered automatically for about five minutes
The DEICE indicator on the unit lights up red
No intervention is required from you; after about five minutes, the air
conditioner starts operating again normally.
High indoor and outdoor
temperatures
If both the indoor and outdoor temperatures are high and you select
the Heat mode, the fan and compressor in the unit may stop at times.
This is normal; simply wait until the air conditioner switches on again.
Temperature and Humidity Ranges
E-
16
The following table indicates the temperature and humidity ranges within which the air
conditioner can be used.
Cooling 21°C to 32°C approx. 21°C to 43°C approx. 80% or less
Heating 28°C or less 0°C to 21°C approx. -
Mode Indoor Temperature Outdoor Temperature Indoor Humidity
Higher humidity levels
Water may condense on and drip from the surface of the unit if
it is used for long periods.
Lower temperatures
A water leakage or some other malfunction may happen if the
heat exchanger freezes.
Higher temperatures
The automatic protection feature may be triggered and the air
conditioner stopped.
If the air conditioner is used at...
Then...
Be sure to clean the air filter periodically to maintain the air conditioner in
the best condition
for a long period of time.
When
cleaning the air conditioner, turn it off and pull out
th
e power plug.
E-
17
CleaningYour Air Conditioner
1 Hold the front grille handle, slightly pull it to the left side and open the front grille.
2 Pull the air filter to the right side.
3 Remove all dust on the air filter with a vacuum cleaner or brush.
4 When you have finished, insert the air filter back into its original position.
5 Wipe the surface of the unit with a neutral detergent and then wipe it again
with d
ry cloth.
(Be sure not to use ben
zene, solvent or other chemical products.)
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
The removal of the front grille makes it easier to clean the air
condition
er. Open the grille as much as possible.
If
you... Then...
Will not be using the
air conditioner
for a
long p
eriod of time
Have not used the air
conditioner
for a long
pe
riod of time
Set the
fan going for a few hours to
dry the inside of the air conditioner
thorough
ly.
Switch the air conditioner
off and
unplug it from the
wall socket.
Clean the filter and outer su
rfaces.
Set the
fan going for a few hours to
dry the inside of the air conditioner
thorough
ly.
Removal and Reassembly of the Front Grille
IMPORTANT
For user's sa
fety, a safety clip has been installed in the front grille.
1 G
rasp the lower part of the front
grille and the front grille handle,
then open th
e grille. (The open
angle of front
grille has not to be
exceeded 25 degree)
2 Lift the front
grille slightly and
rem
ove it from the front panel.
3 Reassem
bling of front grille
should be done in
reverse
order of disasse
mbly.
The air conditioner has two or three grille
grooves depending on the model.
ENGLISH
Solving Common Problems
E-18
Technical Specifications
Design and specifications are subject to change without notice.
Model Power
Supply
Before contacting the after-sales service, perform the following simple checks. They may save
you
the time and expense of an unnecessary call.
The air conditioner does not
operate
at all triggered.
Check that the circuit breaker used for the air conditioner has not been
triggered
.
Check that the power cable is plugged into a wall socket and the
socket
is switched on, if necessary.
Check that the operating mode indicator(COOL, FAN or HEAT) on
the
unit is lit up; if necessary press (On/Off) on the remote control
or
unit.
Problem Explanation/Solution
The air conditioner does not
operate
with the remote control
Check that there are no obstacles between you and the unit.
Replace the remote control batteries if necessary.
Check that you are close enough to the unit (seven metres/yards
or
less).
No beep is heard when you press
(On/O
ff) on the remote control
Check that you are pointing the remote control at the remote
control
sensor on the unit.
Replace the remote control batteries if necessary.
The air conditioner does not cool or
heat.
Check that the correct operating mode has been selected
COO
L or HEAT.
The room temperature may be too low or too high.
Dust may be blocking the air filter; refer to page 17 or 18 for
cleaning
instructions.
Check that there is no obstacle blocking the air flow into or out of
the
unit.
When heating, the required room
temperature
is never reached and
the
air conditioner frequently stops
Check that the required temperature has been set correctly.
Increase the fan speed.
If the air flow is directed downwards, direct it upwards.
The air flow direction does not
change
when you press AIR SWING
Check that the air conditioner has been switched on; if necessary,
press (On/O
ff) on the remote control or unit.
The timer is not correctly triggered Check that the timer has been programmed correctly;
see
page 12~14.
Odours are permeated in the room
during
air conditioning
Air the room.
✴✴✴✴✴✴✴
EA/EB
220-240V~, 50Hz
E-
19
500mm 500mm
75mm
min.
300mm
500mm
150mm min.
"A"
Approx.3
Awning
750mm
100mm or more
Outdoor side
Indoor side
45
45
If the wall is greater than 150mm thick,
cut the
wall back on a 45 angle if possible.
Installation
Before installation, be sure to check the installation area or the air
condition
e
r, and drain hose.
Checkpoints prior to installation
Installation Conditions
1 Ch
e
ck the cabinet and front grille of the unit for any harmful defects
such as s
cratches.
1 As the unit is h
e
avy, the wall or window of the installation area should
have sufficient strength and durability for operation of the air conditioner,
and
for prevention of any vibration or noise.
If it is
weak, reinforcement work should be performed separately.
3 When installing the air conditioner, be sure to obtain sufficient space on
the rear side of the unit
for smooth flow of air.
When op
erating the air conditioner in closed areas such as inner building
with cooling op
eration, and result in trouble with the unit.
See the illus
tration below.
2 It is advisable to install the air conditioner in the north or west side to
pr
event the effect of direct sunlight.
When installing it in the south or east side due to u
n
avoidable
circumstanc
e
s, it is advisable to install the sunshade to prevent the
direct sunligh
t
.
In this ca
s
e, take care not to cause any hindrance to the flow of outside air.
2 Be sure to ch
eck the power supply.
- R
e
fer to the specifications on the label attached to the unit.
Fence, wall
or oth
er
obstac
le
The appliance must be fixed well by screw or similar
metho
d.
"A"
170
MODEL
AZ09/AZ12
ENGLISH
2 Remove the screw located at the lower section of the front grille.
It is secured in the section depending on the mode
l
.
E-
20
Rubber cap
Screws(2EA)
Gasket
Rear
Drain Tube
Installation of the Drain Tube
Fix the
drain tube as shown in the figure.
Installation of the Drain Pan
The procedure
for installing the drain pan should be determined by the
condition of the installing are
a.
1 Open the front
grille; refer to page 15.
3 Re
move the front panel.
4 Re
move two screws on the lower, right and left sides of the unit.
Exampl
e
: High storage
In the case of an area where the drain pan can not be directl
y
installed on the rear side of the unit after installing the air condition
er.
3-1 Press both sides of the cabinet in the directionof the arrow
as s
hown in the figure.
3-2 Pull the
lower part of the front panel slightly forward.
(be
low three inches)
3-3 Lift the front panel u
pward.
Applying
excessive force to remove the front panel
may cause damage to the tab; be sure not to use
excessive force.
In some region, drain tube and drain pan may not be supplied.
Plesae contact the sales a
gent.
5 Remove the chassis from the cabinet.
6 Re
move the rubber cap inserted into the basepan.
7 Fix the
drain pan as shown in the figure, and then connect the drain hose.
(You can use any commercially-available drain hose.)
8 Install the cabinet at the specified area after installing the
drain pan,
and then re-asse
mble it in the original condition.
1 Follow steps 6 and 7 only
In the case of an area where the drain pan can be direc
tly installed
on the rear side of the unit after installing the air condition
er.
Secure the front panel to the case by replacing the screw removed in
step
2. If a screw not removed in setp 2, secure the panel with a
supplied sc
rew.
Rear
Screw
Drain Pan
Rubber cap
Drain Hose
Bottom-Side View with
Drain Pan and Hose in Place
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Samsung AZ12PHHEA/MID Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue