Danfoss DST P30M Guida d'installazione

Tipo
Guida d'installazione
Installation Guide
Pressure Transmitters
MBS 33, MBS 33M, MBS 3000, MBS 3050, MBS 3200, MBS 3250, MBS 3300,
MBS 3350, MBS 4000, MBS 4050, MBS 4003, MBS 4010, DST P300, DST P30M
060R9348
060R9348
© Danfoss | Climate Solutions | 2023.05 AN33134179775201-000502 | 1
Elektrisk tilslutning Se produktskilt Omgivelsestemperatur
Electrical connection: See product label Ambient temperature
Elektrischer Anschluss: Siehe Produktschild Umgebungstemperatur
Raccordement électrique: Voir étiquette du produit Température ambiante
Conexión eléctrica: Ver la pegatina en el producto Temperatura ambiente
Connessione elettrica: Vedi etichetta sulla confezione Temperatura ambiente
EN 175301-803 Screened cable
or Flying leads
(wire)
AMP Econoseal
J series, male ISO 15170 Bayonet EN60947-5-2
M12 x 1 (4-pin) Metri Pack Amphenol 6-pin Lumberg RS 20-03
(on cable)
4-20 mA:
-40 – 100 °C
Voltage:
-40 – 114 °C
Ratiom. 10-90%:
-40 – 114 °C
4-20 mA/Voltage/
Ratiom. 10-90%:
Cable:
-30 – 85 °C
Wire:
-30 – 100 °C
4-20 mA:
-30 – 100 °C
Voltage:
-30 – 105 °C
Ratiom. 10-90%:
-30 – 105 °C
4-20 mA:
-40 – 100 °C
Voltage:
-40 – 125 °C
Ratiom. 10-90%:
-40 – 125 °C
4-20 mA:
-25– 90 °C
Voltage:
-25 – 90°C
Ratiom. 10-90%:
-25 – 90 °C
4-20 mA:
-40 – 100 °C
Voltage:
-40 – 125 °C
Ratiom. 10-90%:
-40 – 125 °C
4-20 mA:
-30 – 100 °C
Voltage:
-30 – 100 °C
Ratiom. 10-90%:
-30 – 100 °C
4-20 mA:
-30 – 90 °C
Voltage:
-30 – 90 °C
Ratiom. 10-90%:
-30 – 90 °C
AMP superseal
1.5 series (on cable) Deutsch DT04-3p
(on wire) Deutsch DT04-4p
Universal
Mate-N-Lock
(on wire)
AMP Econoseal
(AMP 173065)
(on wire)
Molex 5527-2p
(on wire) ITT cannon sure
seal ss 2-p
(on cable)
ITT cannon circular
(on cable)
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 100 °C
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 100 °C
All outputs:
On wire:
-30 – 100 °C
On cable:
-30 – 85 °C
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 100 °C
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 105 °C
4-20 mA:
-40 – 100 °C
Voltage/Ratiome-
tric 10-90%:
-40 – 114 °C
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 80 °C
4-20 mA/Voltage/
Ratiometric
10-90%:
-30 – 100 °C
A
B
C
D
E
F
Pin 5: Forbundet til kapsling
Pin 5: Connected to enclosure
Pin 5: Anschluss an Gehäuse
Broche 5: Connecté au boîtier
Pin 5: Conectado a la cubierta
Polo 5: Collegato al corpo
IEC 947-5-2, M12 x1 (5-pin) MBS 33, MBS 33M, MBS 3000, MBS 3200,
MBS 3300, MBS 4000
MBS 3050, MBS 3250, MBS 3350, MBS 4050 MBS 4010
MBS 3300, MBS 3350
10 Nm
MBS 4010
© Danfoss | Climate Solutions | 2023.05 AN33134179775201-000502 | 2
Output signal Current Ratio-metric Absolute voltage
Supply voltage 9-32 V DC 4,5 - 5,5 V DC (5V nom) 9-32 V DC
Australian approvals:
According to N1297.
American and Canadian approvals:
1. Automatic electrical controls acc. to UL 60730-1 and part 2-6 / CAN/CSA E60730 and part 2-6, le E31024.
2.
Equipment for process measurement and control acc. to UL 61010-1 / CSA C22.2 No. 61010-12, le E494625.
3. Nonincendive electrical equipement for use in Class I, Div. 2, Groups A, B, C, and D, harzardous locations in acc. To UL 121201 / C22.2
No. CSA-213, le E227388 and E510763. Combinations of equipment in systems are subject to investigation by the local Authority
Having Jurisdiction at the time of installation. These components are to be installed within a suitable tool-secured enclosure in end
application.
WARNING - EXPLOSION HAZRD – Do not disconnect equipment unless power has been removed or the area is known to be non-
hazardous.
4. The MWP (max. working pressure) in the range from 1 to 600 bar depending on sensor pressure range. Refer to product lable,
(E494625)
5. Evaluated for pollution Degree 3.
6. Altitude up to 8,000 m.
7. Max. R.H. 95% non-condensing.
8. Overvoltage category I.
9. Powered by class 2 supply.
ATEX
ZONE 2
Applicable in ATEX Zone 2 with medias classied as IIA in accordance to EN 60079-20-1:
Alle elektriske tilslutninger skal udføres iht. ATEX Zone 2 regulativet - samt EN 60079-14.
All electrical connections must comply with the ATEX requirements for Zone 2 - and EN 60079-14.
Alle elektrischen Anschlüsse müssen gemäß ATEX Zone2 Regeln und EN 60079-14 durchgeführt werden.
Tous les raccordements électriques doivent être eectués conformément aux régles ATEX zone 2 et EN 60079-14.
Todas las conexiones eléctricas deben ser realizadas de acuerdo a los requerimientos de la normativa ATEX zona 2 y EN 60079-14.
Tutti i collegamenti elettrici devono essere eseguiti secondo le normative ATEX Zone e EN 60079-14.
Ved anvendelser i ATEX Zone 2 områder ved temperaturer <-10 °C skal kabel og stik beskyttes mod slag.
When used in ATEX Zone2 areas at temperatures <-10 °C the cable and plug must be protected against impact.
Wenn in ATEX Zone 2 bei Temperaturen <-10 °C verwendet werden, müssen die Kabel und Stecker gegen Stöße geschütz werden.
Lorsqu’ils sont utilisés en zone 2 ATEX à des températures <-10 °C, le câble et le connecteur doivent être protégés contre les chocs.
Cuando se usa en áreas ATEX Zona 2, a temperaturas <-10 °C, el cable y conector deben protegerse contra impactos.
Per l’uso in ATEX Zona 2 a temperature <-10 °C, il cavo ed il connettore devono essere protetti contro gli urti.
Stikket må ikke ernes, når transmitteren er tilsluttet.
Plug must not be removed when sensor is energized.
Stecker darf nicht entfernt werden, wenn der sensor aktiviert ist.
Le connecteur ne doit pas être retiré lorsque le capteur est
encore sous tension.
El conector no debe retirarse cuando el sensor esté activado.
Il connettore elettrico non deve essere scollegato quando
il sensore è in funzione.
Kabelet må ikke udsættes for nogen mekaniske skader, korrosion,
vibration, varme eller UV stråling.
Cable must neither be exposed for any mechanical damage,
corrosion, vibration, heat nor UV radiation.
Kabel müssen weder auf mechanische Beschädigungen,
Korrosion, Vibration, Hitze noch UV-Strahlung ausgesetzt werden.
Le câble ne doit être exposé à aucun dommage mécaniques, à la
corrosion, àux vibrations, à la chaleur où aux radiations UV.
El cable no deber estar expuesto a ningún tipo de radiación,
daños mecánicos, corrosión, vibraciones, calor ó UV.
Il cavo non deve essere esposto a danni meccanici, corrosione,
vibrazioni, fonti di calore o raggi UV.
EN60079-0; EN60079-7
Applicable in Zone 2 electrical connectors see overview page 1.
II 3G
Ex ec IIA T4 Gc
-20°C<Ta<+85°C
Type MBS 33, MBS 33M, MBS 3000
MBS 3050, MBS 4000, MBS 4003
MBS 4010
MBS 3200, MBS 3250, MBS 3300, MBS 3350
DST P300, DST P30M
Max ambient temperature /T-code 85 °C / T4 125 °C / T4
Electrical connectors For UL approved see overview page 1
Note: Deutsch DT04- 4P
Skal installeres i en indkapsling, der opfylder kravene til slagstyrke i henhold til EN 60079-0
Must be installed in an enclosure that complies with the impact requirements in accordance to EN 60079-0
Muss in ein Gehäuse eingebaut werden, das die Schlagfestigkeitsanforderungen nach EN 60079-0 erfüllt
Doit être installé dans un btier conforme aux exigences en matière d’impact conformément à la norme EN 60079-0.
Debe ser instalado en una cubierta que cumpla con los requisitos de impacto de acuerdo a EN 60079-0
Deve essere installato in un contenitore di protezione conforme ai requisiti di impatto secondo EN 60079-0