10
GYSFLASH 32.12 PL
EN
GENERAL DESCRIPTION
The GYSFLASH 32.12 PL is a high power stabilized power supply based on inverter technology. Designed to support 12 V batteries
(liquid/AGM/gel and lithium LiFePO4) in vehicles in the diagnostic phase or in the showroom, it also guarantees an ideal charging
quality for the maintenance of the most advanced models. It is considered a xed device not a mobile product.
This charger is suitable for the charge of:
- 12 V lead batteries (6 cells in series) from 15 Ah to 375A h.
- LFP batteries 12V (4 elements in series) from 7 Ah to 375 Ah.
CALIBRATION CABLE
Procedure for the calibration of the charging leads in order for the charger to compensate any voltage drop due to the length or
condition of the cables. It is strongly recommended to perform this procedure each time the cables are modied or changed.
1. Before undertaking the procedure, make sure that the charger is disconnected from the mains socket.
2. Short-circuit the ends of the charging leads.
3. Press buttons (#1 - page 39) and (#6 - page 39) simultaneously.
4. Plug in the mains plug while holding down the two buttons until the indicator light or lights up.
Results :
- Indicator is on: the calibration was successful.
- Indicator is on: the calibration failed, disconnect the mains plug and restart the procedure.
5. Unplug the mains plug until the charger switches off.
START UP
1. Connect the charger to the battery.
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz).
3. Select the mode by pressing the mode button (#1 - page 45) and the charging current by pressing the current selection
button (#6 - page 45). After roughly ve seconds, the charge starts automatically.
4. During the charge, the device indicates charge progress. When indicator ashes, the battery is ready to start the engine.
Once indicator is steady, the battery is fully charged.
5. Charging can be interrupted at any time by unplugging the power plug or pressing the mode button .
6. After the charge, disconnect the charger from the mains, then disconnect the clamps from the battery.
CHARGE MODES
• Description of charging modes and currents :
Lead-acid CHARGE mode (14.6 V/30 A max) :
Mode designed for the recharge of 12V lead-acid batteries from 15 Ah to 375 Ah. 7 step automatic main-
tenance cycle.
MMode CHARGE Lithium (14.4 V/30 A max) :
Mode designed for the recharge of 12V lithium batteries between 7 Ah and 375Ah. 8 step automatic
maintenance charge cycle.
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which
disconnect the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the GYSFLASH 32.12 PL to charge the battery, the UVP
protection must be disabled. To do this, place the charger in Lithium charging mode, then
press and hold the mode button for 10 seconds. The charger will then deactivate the
UVP protection and automatically start charging.
Charging current 7 A/ 15 A/ 30 A :
Select to optimise the charging current according to the type of battery (lead or lithium) and its capacity.
Charging current 7 A 15 A 30 A
Battery capacity
Pb 15 60 Ah 60 100 Ah 100 375 Ah
LFP 7 15 Ah 15 30 Ah 30 375 Ah
(21 45 Ah EqPb*) (45 90 Ah EqPb*) (90 1100 Ah EqPb*)
*Lead-acid battery equivalent : A lithium battery has a better starting performance (CCA) than a lead-acid battery. This is why
some lithium battery manufacturers indicate the battery lead-acid equivalent (EqPb) that indicates the capacity of a lead-acid
battery with the same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a
lead-acid battery of around 30 Ah.