Excell EX-2001NC Racer Manuale utente

Tipo
Manuale utente
EXCELL PRECISION CO., LTD.
© EXCELL PRECISION CO., LTD 2008. All rights reserved Worldwide.
The information contained herein is the property of EXCELL PRECISION
CO., LTD and is supplied without liability for errors or omissions. No part
may be reproduced or used except as authorised by contract or other
written permission. The copyright and the foregoing restriction on
reproduction and use extend to all media in which the information may be
embodied.
EX-2001 NC RACER ZSME300000091
1
EXCELL PRECISION CO., LTD.
TABLE OF CONTENTS
SAFETY.......................................................................................................................................3
CLEANNING TIPS.......................................................................................................................4
CHAPTER 1 OPERATION GUIDE ..............................................................................................5
CHARTER 2 SPECIFICATIONS..................................................................................................7
CHAPTER 3 FRONT AND REAR PANEL...................................................................................9
3-1 FRONT PANEL ..................................................................................................................9
3-2
REAR PANEL...................................................................................................................10
CHAPTER 4 INSTALLATION....................................................................................................11
4-1
LOAD CELL.....................................................................................................................11
4-2 INDICATOR INSTALLATION AND DIMENSIONS............................................................11
CHAPTER 5 CAPACITY CALIBRATION ..................................................................................13
5-1 PARAMETER SETTING...................................................................................................13
5-1-1 Flow Diagram...........................................................................................................13
5-1-2 Description...............................................................................................................14
5-2 CALIBRATION SETTING.................................................................................................15
5-2-1 Calibration Procedure.............................................................................................15
5-2-2 Zero Calibration.......................................................................................................15
5-2-3 Weight Calibration...................................................................................................15
5-3 LINEARITY CALIBRATION .............................................................................................16
5-4 PASSWORD SETTING ....................................................................................................19
5-5 ERROR MESSAGES .......................................................................................................20
CHAPTER 6 ANIMAL SCALE FUNCTION SETTING...............................................................21
CHAPTER 7 INTERFACES.......................................................................................................22
7-1 OP-01 RS-422 & RS-485 INTERFACE.............................................................................22
EX-2001 NC RACER ZSME300000091
2
EXCELL PRECISION CO., LTD.
7-2 OP-02 PARALLEL BCD OUTPUT....................................................................................26
7-3 OP-03 ANALOGUE CURRENT / VOLTAGE OUTPUT INTERFACE................................28
7-4 OP-05 PARALLEL PRINTER OUTPUT & RS-232 & CURRENT LOOP...........................29
7-5 OP-06 RS-232 & CURRENT LOOP..................................................................................32
7-6 OP-07 RS-232, CURRENT LOOP & DATA CLOCK OUTPUT..........................................33
7-7 OP-08 CONTROL I /O (2I /4O) INTERFACE.....................................................................34
CHAPTER 8 MAINTENANCE ...................................................................................................38
8-1
RESET ALL PARAMETERS BACK TO DEFAULT...........................................................38
8-2
RESET GENERAL FUNCTION PARAMETERS BACK TO DEFAULT.............................38
8-3 SELF-DIAGNOSIS MODE ...............................................................................................38
8-3-1 7 Digit Display and LED Status Light Diagnosis................................................39
8-3-2 Keyboard and Calibration ON / OFF Switch Diagnosis .....................................39
8-3-3 RS-232 Serial Output / Input Interface Diagnosis ( OP-06 / OP-07 )..................39
8-3-4 BCD Parallel Output Interface Diagnosis ( OP-02 )............................................39
8-3-5 Analogue Current Output Interface Diagnosis ( OP-03 ) ...................................40
8-3-6 Parallel Printer Interface Diagnosis ( OP-05 ).....................................................40
8-3-7 Main Board EEPROM Memory Diagnosis...........................................................40
8-3-8 OP-08 Control I /O (2I /4O) Diagnosis..................................................................40
CHAPTER 9 FUNCTION TABLE...............................................................................................41
APPENDIX: 7-SEGMENT DISPLAY CHARACTERS...............................................................46
EX-2001 NC RACER ZSME300000091
3
EXCELL PRECISION CO., LTD.
SAFETY
Disconnect the main power supply before opening the indicator housing or disassembling
the indicator.
In the process of maintenance, please cut off the source if contacting to any electron, socket
and groupware for fear of getting an electric shockshort current and shattering weight
controller or error movement.
Avoid using the indicator in direct sunlight. The operating ambient temperature range is -10 ~
+40 °C.
Use 100 V ~ 240 V AC
When using AC source wiring, the front line “L” should be connected to weight controller “L”.
The neutral line “N” should be connected to weight controller “N”. “ ” of weight controller
should connected to the ground.
Connect the ground correctly. (Ground impedance < 100 ) Avoid connecting the ground
connection with other equipment. The indicator must always be connected to the electrical
ground (earth) for safe operation.
In the industrial surrounding, the main power supply has non-seasonal and short-lived pulse
(high electric current or high voltage) because of high power instrument (start-up and
closedown of the source). Users take necessary actions by themselves to protect weight
controller and other periphery instrument. (Using isolated transformer or restraining
groupware)
The weight installation wiring conforms to standard law in the user’s country.
When installing, keep the indicator away from noise such as high voltagehigh current and
high power switches.
The distances of input wiringoutput wiring and power wiring are 30 ~ 50 mm. Try to across
vertically if not being separated and avoid being set parallelly.
The diameter of I/O and BCD wiring is 12 AWG ~ 24 AWG. Please select the proper diameter
of the wiring materials. (The length 10 m)
Set proper resolution for system installation for fear of decreasing the stability and reliability.
When the temperature range is -10 ~ +40 °C and the resolution is over 1 / 3 000, please
select the weight load cell passing C3.
EX-2001 NC RACER ZSME300000091
4
EXCELL PRECISION CO., LTD.
CLEANNING TIPS
Please clean the indicator by alcohol
and chemical medicament.
Clean it with a wet cloth and gentle cleanser
and dry it with a soft cloth.
Do not swash the indicator.
Do not breakout and maintain the indicator.
If there is something wrong with the indicator,
please contact your supplier.
Keep away from high temperature,
damp or direct sunlight conditions.
Do not shake the indicator fiercely.
EX-2001 NC RACER ZSME300000091
5
EXCELL PRECISION CO., LTD.
CHAPTER 1 OPERATION GUIDE
FUNCTION OPERATION PROCEDURE DESCRIPTION
General function
setting
Press and hold the key,
then press the
Refer to Chapter 9 Functions Table
to set FUNC. 0 ~ FUNC. 7
Capacity parameter
setting
Switch the capacity calibration
switch to “ON”
and then press the
Set the parameter for decimal
point, max. capacity, min. division,
zero tracking, unstable detection
Refer to < 5-1 > Parameter Setting
Calibration
Switch the capacity calibration
switch to “ON”
and then press the
Calibration procedures.
Refer to < 5-2 > Calibration Setting
Self-diagnosis mode
Turn on the indicator,
press and hold and
the indicator starts the self-test
procedure.
Refer to < 8-3 > Self-diagnosis
Mode for details
Reset all parameters
back to default
Switch the calibration switch to
“ON”, turn on the indicator,
press and hold and
while the indicator is in the
self-testing sequence
Refer to < 8-1 > Reset All
Parameter Back to Default
Reset general function
parameter back to
factory standard setting
Turn on the indicator,
press and hold , followed
by pressing
while the indicator is in the
self-testing sequence
Refer to < 8-2 > Reset General
Function Parameter Back to
Default
Display software version
Turn on the indicator,
press and hold the
while the indicator is in the
self-test sequence
The main display section displays
the software version, press any key
to exit
Function parameter
setting
Press and hold ,
followed by pressing
HI, LO, Zero Band parameter
setting
ENTER
F n
F n
C A L
ENTER
GROSS
NET
F n
ENTER
F n
ENTER
C A L
ENTER
C A L
EX-2001 NC RACER ZSME300000091
6
EXCELL PRECISION CO., LTD.
Operation of Keys in the Setting Mode
Increase the number of the flashing digit by one
Decrease the number of the flashing digit by one
Shift the flashing digit one space to left
Shift the flashing digit one space to right
Save the settings
Exit the settings
ZERO
+
GROSS
NET
PRINT
TARE
ENTER
STANDBY
OPERAE
EX-2001 NC RACER ZSME300000091
7
EXCELL PRECISION CO., LTD.
CHARTER 2 SPECIFICATIONS
ANALOGUE
Load cell excitation : DC 5 V ± 5%120 mA (up to 8 × 350 load cells)
Maximum signal voltage : 20 mV
Input sensitivity : 0.3 μV / D (minimum)
Conversion rate : Approximately 120 times/s (maximum)
Internal Resolution : 19 bits
DIGITAL
Main display : 7 digits, bright red LED, 20 mm, 7-segment
Status display : 6 character display, bright red LED
Display update rate : 50 times/s
Display capacity : -199 999 to 999 999
Min division : 125102050
Decimal point : 00.00.000.0000.0 000
Memory : Calibration parameters and function settings saved in
EEPROM
EX-2001 NC RACER ZSME300000091
8
EXCELL PRECISION CO., LTD.
INTERFACE
OP-01 RS-422 / RS-485
OP-02-1 Parallel BCD output ( TTL )
OP-02-2 Parallel BCD output ( O.C. )
OP-03 Analog output ( 4 ~ 20 mA )
OP-05 Parallel Printer output / RS-232C & CURRENT LOOP
OP-05 Free Form
OP-06 RS-232C & CURRENT LOOP
OP-07 RS-232C & CURRENT LOOP & Data Clock Output
OP-08 Control I / O ( 2I /4O )
POWER SUPPLY INPUT
AC Power : 100 V ~ 240 V
Power consumption: Approximately 10 W
OTHER
Operating temperature and humidity range : -10 ~ 40 ,< 85 % RH
Dimension (mm) : 210 ( W ) × 108 ( H ) × 207 ( D )
Weight : Approximately 1.7 kg
EX-2001 NC RACER ZSME300000091
9
EXCELL PRECISION CO., LTD.
CHAPTER 3 FRONT AND REAR PANEL
3-1 FRONT PANEL
1
MAIN DISPLAY
Displays gross weight or net weight
2 STATUS INDICATION LIGHTS
POWER : Power Indication
ZERO : Zero status indication
MOTION : Unstable weighing indication
GROSS : Main display section currently displays gross wt.
NET : Main display section currently displays net wt.
TARE ENTERED : Tare indication
3 KEYS
1) Standby mode ON / OFF
2) When setting the parameter or calibration, it works as quit or exit from setting
1) Sets weight back to zero
2) When setting the parameter or calibration, it cycles from 0 to 9
1) Tare function
2) When setting the parameter or calibration, it cycles from 9 to 0
1) Switches between gross wt. / net wt. on the main display
2) When setting the parameter or calibration,
it shifts the flashing character to the left
1) Manually output serial / parallel data
2) When setting the parameter or calibration, it shifts the flashing character to the right
1) Weight accumulation, sub-total function (for OP-05)
2) Sets capacity parameter
1) Weight accumulation, grand-total function (for OP-05)
2) Capacity calibration
Confirmation key
1
2
3
4
STANDBY
OPERAE
ZERO
+
GROSS
NET
TARE
PRINT
ENTER
F n
C A L
POWER ZERO MOTION GROSS NET TARE ENTERED
ON
STANDBY
OPERAE
ZERO
+
TARE
GROSS
NET
PRINT
F n
C A L
ENTER
EX-2001 NC RACER ZSME300000091
10
EXCELL PRECISION CO., LTD.
DATA IN / OUT
LOAD CELL
FUSE/0.5A
AC 100V~240V
CONTROL IN / OUTPUT
2 1
C2 C1
4 3 2 1
OUTPUT
INPUT
before opening the covers.
Isolating the ac power
! WARNING
12
3
4
5
4 CAPACITY PARAMETER & CALIBRATION SWITCH
Slide the switch to the left is “ON” and Slide the switch to the right is “OFF”
3-2 REAR PANEL
1. AC power in terminal
2. Fuse 250 V / 0.5 A
3. Load cell connector
4. Optional interface location (if fitted)
5. Control I/O Interface location
EX-2001 NC RACER ZSME300000091
11
EXCELL PRECISION CO., LTD.
6
1
2
8
7
5
4
3
Load cell
Load cell cable
Shield
SEN+
SIG-SIG+
EXC+
EXC-
SEN-
CHAPTER 4 INSTALLATION
4-1 LOAD CELL
Four-wire (five-wire) load cell Six-wire (seven-wire) load cell
Pin 1 & 2 short, connected to EXC+ Pin 1 connected to EXC+
Pin 3 & 4 short, connected to EXC- Pin 2 connected to SEN+
Pin 5 connected to SIG+ Pin 3 connected to EXC-
Pin 6 connected to SIG- Pin 4 connected to SEN-
Pin 7 connected to the Shield Pin 5 connected to SIG+
Pin 6 connected to SIG-
Pin 7 connected to the Shield
4-2 INDICATOR INSTALLATION AND DIMENSIONS
2 The indicator can be installed in a control panel as detailed below
Packing
Panel
Fixed Rail
Load Cell
Load Cell Cable
Shield
1
2
3
4
5
6
7
8
EX-2001 NC RACER ZSME300000091
12
EXCELL PRECISION CO., LTD.
! WARNING
before opening the covers.
Isolating the ac power
LOAD CELL
AC 100V~240V
IN / OUTPUT
2
FUSE/0.5A
CONTROL
INPUT
1 2
OUTPUT
4
C2 C1
3 1
DATA IN / OUT
2 INDICATOR DIMENSIONS (measurement unit: mm)
EX-2001 NC RACER ZSME300000091
13
EXCELL PRECISION CO., LTD.
CHAPTER 5 CAPACITY CALIBRATION
5-1 PARAMETER SETTING
Switch the capacity calibration switch to “ON” and the display shows .
Press the key and the display shows . then enter the setting mode.
5-1-1 Flow Diagram
1.
2.
3.
4.
4.
5.
5.
.
Decimal Point
. .
Setup completed
Max. Capacity
Setup completed
Min. Division
.
Setup completed
Zero Tracking
. . .
Setup completed
Unstable
Detection
.
Switch the
calibration switch
to OFF
Setup completed
DISPLAY
F n
ENTER
STANDBY
OPERAE
ENTER
EX-2001 NC RACER ZSME300000091
14
EXCELL PRECISION CO., LTD.
5-1-2 Description
1) Zero Tracking
Display Division / Time
. . .
1 d / 1 s
. . .
2 d / 1 s
. .
.
3 d / 1 s
. .
.
4 d / 1 s
. . .
1 d / 2 s
. . .
2 d / 2 s
. .
.
3 d / 2 s
. .
.
4 d / 2 s
. .
No zero tracking
2) Unstable Detection
Display Division / Time
.
1 d / s
.
2 d / s
.
3 d / s
.
4 d / s
.
5 d / s
.
No detection
EX-2001 NC RACER ZSME300000091
15
EXCELL PRECISION CO., LTD.
5-2 CALIBRATION SETTING
Please allow the indicator to warm up at least 15 to 30 minutes before calibration.
Switch the capacity calibration switch to “ON” and the display shows .
Press the key and the display shows . then enter the setting mode.
5-2-1 Calibration Procedure
Zero Calibration
Weight Calibration
5-2-2 Zero Calibration
a) Make sure that there are no objects on the weighing platform and press
the key, after the indicator has stabilized the display will show
……. ”. The calibration is completed after about 5 seconds.
b) To skip the “Zero calibration” procedure, press the key.
5-2-3 Weight Calibration
a) Place an accurate weight onto the platform; use the front panel keys to key in
the weight value. Press the key, after the indicator is stabilized the display will
show “ ……. ”. The calibration is completed after about 5 seconds.
b) To skip the weight calibration, press the .
Zero Calibration
Com
p
leted
Confirmation
completed
Switch the calibration
switch to OFF
Place
calibrate
d weight
C A L
ENTER
ENTER
STANDBY
OPERAE
ENTER
ENTER
STANDBY
OPERAE
ENTER
STANDBY
OPERAE
ENTER
STANDBY
OPERAE
EX-2001 NC RACER ZSME300000091
16
EXCELL PRECISION CO., LTD.
Before linearity calibration, make sure “Zero calibration” and “Weight Calibration” are properly
performed. Set the calibration switch to ON position.
Press key
Press key
Choose the calibration value Press key to previous step
Press key
Press key Press key to previous step
Enter the correct weight value
Press key
The calibrated weight value
is displayed when the
signal is stable
Press to next step
After finishing the first linearity calibration,
choose to continue or exit the linearity mode
by pressing .
Refer to 5-4 Error Messages when any error message appears during the procedure.
5-3 LINEARITY CALIBRATION
.
.
....
Five point linearity calibration.
Choosing from 1P ~ 5P by
pressing key.
No linearity
calibration value at this point
linearity calibration
value present at this point
The weight value is displayed.
Increase the number of
the flashing digit by one
Decrease the number
of the flashing digit by
one
Shift the flashing digit
one space to left
Shift the flashing digit
one space to right
Save the settings
Exit the settings
Press and key to
choose linearity calibration
C A L
ZERO
+
TARE
ENTER
ZERO
+
TARE
ENTER
STANDBY
OPERAE
ENTER
STANDBY
OPERAE
ENTER
STANDBY
OPERAE
STANDBY
OPERAE
TARE
PRINT
ZERO
+
GROSS
NET
ENTER
STANDBY
OPERAE
EX-2001 NC RACER ZSME300000091
17
EXCELL PRECISION CO., LTD.
Recall Linearity correction point
Set the calibration switch to ON position.
Press key
Choose linearity calibration
Press key
Press key
Press key
After finishing the first linearity calibration,
choose to continue or exit the linearity mode
by pressing .
The weight value is displayed.
Increase the number of
the flashing digit by one
Decrease the number
of the flashing digit by
one
Shift the flashing digit
one space to left
Shift the flashing digit
one space to right
Save the settings
Exit the settings
C A L
ENTER
GROSS
NET
STANDBY
OPERAE
STANDBY
OPERAE
ZERO
+
TARE
Five point linearity calibration.
Choosing from 1P ~ 5P by
pressing key.
No linearity
calibration value at this point
Linearity
calibration value at this point
TARE
PRINT
ZERO
+
GROSS
NET
ENTER
STANDBY
OPERAE
EX-2001 NC RACER ZSME300000091
18
EXCELL PRECISION CO., LTD.
Clear a linearity correction point
Set the calibration switch to ON position.
Press key
Choose linearity calibration
Press key
Press key
Press key
After finishing the first linearity calibration,
users can choose to continue or exit the
linearity mode by pressing .
Five point linearity calibration.
Choosing from 1P ~ 5P by
pressing key.
No linearity
calibration value at this point
Linearity calibration
value at this point
The weight value is displayed.
C A L
ENTER
PRINT
ENTER
STANDBY
OPERAE
TARE
ZERO
+
Increase the number of
the flashing digit by one
Decrease the number
of the flashing digit by
one
Shift the flashing digit
one space to left
Shift the flashing digit
one space to right
Save the settings
Exit the settings
TARE
PRINT
ZERO
+
GROSS
NET
ENTER
STANDBY
OPERAE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Excell EX-2001NC Racer Manuale utente

Tipo
Manuale utente

in altre lingue