Medicines P0016V Manuale utente

Tipo
Manuale utente
www.mediclinics.com
CAMBIA PAÑALES
BABY CHANGING STATION
TABLE À LANGER
WICKELTISCH
TROCADOR DE FRALDAS
FASCIATOIO
ΕΠΙΤΟΙΧΙΑ ΑΛΛΑΞΙΕΡΑ ΜΩΡΟΥ
ПЕЛЕНАЛЬНЫЙ СТОЛ
BABYVERSCHOONTAFEL
CP0016V / CP0016VCS / CP0016VCSB
INSTRUCCIONES DE INSTALACIÓN Y DE SEGURIDAD
INSTALLATION AND SAFETY INSTRUCTIONS
INSTRUCTIONS RELATIVES À L'INSTALLATION ET À LA SÉCURITÉ
ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΑΣΦΑΛΕΙΑΣ
MONTAGEANLEITUNG UND SICHERHEITSHINWEISE
ISTRUZIONI DI MONTAGGIO E DI SICUREZZA
РУКОВОДСТВО ПО УСТАНОВКЕ И БЕЗОПАСНОСТИ
INSTALLATIE- EN VEILIGHEIDSINSTRUCTIES
MUY IMPORTANTE. CONSERVE ESTAS INSTRUCCIONES PARA FUTURAS CONSULTAS. LEA
DETENIDAMENTE Y TENGA EN CUENTA, TODAS Y CADA UNA DE LAS INSTRUCCIONES Y
RECOMENDACIONES QUE SE DESCRIBEN A LO LARGO DE TODO ESTE MANUAL.
- Sólo un técnico cualificado puede instalar, ajustar y realizar el mantenimiento de este cambia pañales.
Todas las operaciones que se realicen sobre él deben estar de acuerdo con la legislación y la
normativa de seguridad, tanto europea como local, que estén en vigor en ese momento. Mediclinics,
S.A. no se responsabilizará por los daños que se originen por una mala instalación o un mal
mantenimiento o un mal uso de este cambia pañales.
- Es muy importante que, una vez instalado y puesto en servicio, este cambia pañales sea revisado
periódicamente para comprobar que sigue firmemente sujeto a la pared y no sufre ningún desperfecto
que pueda causar algún tipo de daño a los usuarios. Es muy importante comprobar que el cambiador
de pañales abre y cierra correctamente.
- Cualquier componente adicional o pieza de recambio que se necesite para este cambia pañales
deberá ser adquirido solamente al fabricante o a un distribuidor autorizado.
- Bajo ninguna circunstancia debe utilizarse el cambia pañales si hay indicios de que alguna de las
partes del mismo está rota, rasgada o perdida.
- El cambia pañales debe fijarse a una pared capaz de soportar sin problema las cargas a las que
estará sometido diariamente y deben utilizarse los medios de sujeción más apropiados para cada tipo
de pared.
- El peso total máximo recomendado para este cambiador de pañales es de 11kg y niños de hasta 12
meses según EN 12221-1:2008+A1:2013 Tipo 1. El cambiador se ha testeado satisfactoriamente con
una carga de 50 kg durante 1 hora según punto 5.7 de la norma EN 12221-2:2008+A1:2013. Un peso
excesivo puede crear situaciones de peligro o inestabilidad para el bebé.
- Todas las uniones de montaje, así como las fijaciones a la pared deben estar siempre correctamente
apretadas y deben ser revisadas regularmente, para comprobar que siguen correctamente fijadas.
- Es muy importante instalar el cambia pañales lejos de fuentes de calor o de fuego abierto para evitar
el riesgo de incendio de la unidad.
- Si el cambia pañales sufre un acto vandálico es muy importante desmontarlo de la pared y realizar una
inspección minuciosa de la unidad y de la pared donde va instalado para detectar y solucionar
cualquier problema que luego pueda derivar en un accidente.
- Para una mayor comodidad y seguridad deben estar siempre disponibles en el cambia pañales
sabanitas higiénicas y la unidad debe ser limpiada a fondo todos los días para reducir al mínimo la
propagación de enfermedades infecciosas.
- Bajo ninguna circunstancia deje al bebé desatendido en ningún momento encima del cambia pañales.
- Colocar al bebé siempre en el centro del cambia pañales
- El cambia pañales ha sido diseñado para ser usado sin cojín. Por favor no usar cojín o cualquier otro
elemento que pueda afectar la posición del niño en el cambia pañales.
“Bevat BioCote zilverfosfaatglas1
antimicrobiële technologie2 om het
oppervlak te beschermen en degradatie
door microbiële groei te voorkomen3.”
ESPAÑOL
INSTRUCCIONES DE SEGURIDAD
ANTES DE EMPEZAR
ESPAÑOL
www.mediclinics.com
-3-
Herramientas necesarias
Para realizar la instalación del cambia pañales serán necesarias las siguientes herramientas:
Elementos de fijación suministrados
Con el cambia pañales se suministran los siguientes elementos de fijación:
Seis tornillos de cabeza Philips autorroscantes (DIN
7981/C A2 de Ø6,3x70 mm) para fijar el cambia pañales
a la pared
Seis tacos de nylon de Ø10mm para insertar en los
agujeros de instalación del cambia pañales
Cuatro arandelas planas (DIN125 M8 A2) que se
montarán junto a los cuatro tornillos de cabeza Philips
autorroscantes de Ø6,3x70 mm inferiores de la estructura
metálica
Cuatro tornillos de cabeza Philips sin punta (DIN7985 A2
M4x8 mm) para fijar el dispensador de sabanitas a la
estructura metálica de la pared
Cuatro arandelas planas (DIN125 M4 A2) que se
montarán junto a los cuatro tornillos de cabeza Philips sin
punta (M4x8 mm) para fijar el dispensador de sabanitas
INSTRUCCIONES DE MONTAJE
Paso 1. Inspección del material
Es muy importante realizar una inspección visual del embalaje del cambia pañales exteriormente, para
verificar que no haya sufrido ningún tipo de daño durante el transporte y la manipulación. Si se observan
daños en el embalaje se deberá inspeccionar cuidadosamente el cambia pañales para comprobar si hay
algún tipo de desperfecto. EL CAMBIA PAÑALES NO DEBERÁ SER INSTALADO, BAJO NINGUNA
CIRCUNSTANCIA, SI SE OBSERVA ALGÚN TIPO DE DAÑO.
Sacar todo el material fuera del embalaje y comprobar que no falte ningún componente de montaje (cama
con la estructura de montaje a la pared y el dispensador de sabanitas higiénicas), ni ninguna pieza de
tornillería (ver tabla de elementos de fijación suministrados).
Paso 2. Preparación de la superficie de montaje
Una vez desembalado e inspeccionado el material se seleccionará el área de la pared donde ha de
instalarse el cambia pañales. Es muy importante tener en cuenta y respetar, las distancias de operación
señaladas en la figura inferior y que son de 75 mm a ambos lados del chasis de fijación del cambia
pañales a la pared y de 895 mm de la cama del cambia pañales cuando está abierta, respecto de la
pared.
La altura recomendada de instalación es de 800 mm desde el suelo hasta la parte más baja del cambia
pañales. El croquis siguiente muestra a qué altura deben realizarse los agujeros para que el cambia
pañales quede instalado a la altura recomendada:
www.mediclinics.com
-5-
Siguiendo el esquema anterior marcar con el lápiz, sobre la pared, los dos agujeros superiores de la
estructura de sujeción del cambia pañales. Es muy importante asegurar que las ubicaciones que se hayan
marcado a lápiz para los agujeros de montaje estén al mismo nivel antes de realizar las perforaciones.
Instalación según normativa ADA.
Si es necesario que la instalación cumpla con la normativa ADA (EE.UU), la instalación tiene que hacerse
teniendo en cuenta las siguientes cotas de instalación.
Paso 3. Montaje de la cama y la estructura de sujeción del cambia pañales
a la pared.
Instalación sobre pared de ladrillo, mampostería o cemento.
Con la broca de mampostería, realizar los dos taladros de Ø10 mm de la parte superior del cambia
pañales que previamente han sido marcados, a una profundidad mínima de 70 mm.
Limpiar de polvo los dos agujeros e introducir dentro de ellos dos de los tacos de nylon de Ø10 mm.
Atornillar dos de los tornillos de montaje de Ø6,3x70 mm en los dos tacos colocados anteriormente, no
llegando a fondo y dejando un espacio de aproximadamente 5mm entre la cabeza del tornillo y la pared.
Colgar la estructura de sujeción del cambia pañales de los dos tornillos colocados previamente,
verificando que la unidad está perfectamente nivelada. Una vez asegurado que el cambia pañales está
perfectamente nivelado apretar a fondo los dos tornillos superiores.
Usar los cuatro orificios inferiores de la estructura de sujeción del cambia pañales a la pared, como guía
para marcar la posición de los cuatro taladros restantes.
Aflojar los tornillos superiores y retirar el cambia pañales.
Tomando como referencia las marcas realizadas anteriormente, taladrar los cuatro agujeros inferiores con
la broca de Ø10mm y a una profundidad mínima de 70 mm.
Una vez realizados proceder a su limpieza interior y colocar los cuatro tacos de nylon de Ø10 mm
restantes.
Volver a colocar el cambia pañales sobre los dos tornillos superiores y fijar la estructura a la pared con los
cuatro tornillos Ø6,3x70 mm y las cuatro arandelas DIN125 M8 de los agujeros inferiores, después apretar
a fondo los dos tornillos superiores, en la siguiente figura se muestra la distribución de los componentes:
Comprobar que los seis tornillos de fijación de la unidad a la pared han sido correctamente apretados y
que el cambia pañales se encuentra firmemente fijado a la pared.
Instalación sobre pared de placas de yeso/pladur o huecas.
Los sistemas de fijación suministrados con este cambia pañales no son aptos para realizar la
instalación del mismo sobre paredes de placas de yeso/pladur o huecas.
Para llevar a cabo la instalación de esta unidad en paredes de este tipo se deberán utilizar anclajes y
útiles específicos para sujeción para paredes de placas de yeso / pladur o huecas.
Debido a la problemática que plantean las instalaciones en este tipo de paredes, en cuanto a sujeción se
refiere, se recomienda que la instalación la lleven a cabo técnicos especialistas en instalaciones sobre
este tipo de paredes. Mediclinics no se responsabiliza de las instalaciones de sus cambia pañales
llevadas a cabo sobre paredes de placas de yeso / pladur o huecas.
Paso 4. Montaje del dispensador de sabanitas a la estructura de sujeción
del cambia pañales
Tomar el dispensador de sabanitas y después de verificar que no esté dañado ni rayado, posicionarlo
sobre la estructura metálica, siguiendo la secuencia de pasos indicada a continuación y asegurando así
su correcta posición con los ejes metálicos
www.mediclinics.com
-7-
Abrir el dispensador de sabanitas con la llave especial suministrada. Los cuatro orificios de fijación de este
dispensador de sabanitas a la estructura de sujeción del cambia pañales quedarán a la vista.
Encarar el dispensador con la estructura de sujeción del cambia pañales y alinear los orificios de montaje
del dispensador.
Fijar el dispensador de sabanitas a la estructura de sujeción del cambia pañales con los cuatro tornillos
M4x8mm y las cuatro arandelas planas DIN125 M4, tal y como se muestra en la figura. Comprobar y
asegurar su correcta fijación.
Paso 5. Revisión final antes de la puesta en servicio
Limpiar y desinfectar a fondo el cambia pañales. Es muy importante que se verifique que la unidad abre y
cierra con suavidad y que no se ha producido ningún desperfecto durante la instalación del cambia
pañales. En resumen es muy importante que se verifique, una vez finalizada la instalación del cambia
pañales que está en perfecto estado para ser utilizado sin problemas.
Recuerde que cualquier componente adicional o pieza de recambio que se necesite para este cambia
pañales deberá ser adquirido solamente al fabricante o a un distribuidor autorizado.
COMPONENTE
CÓDIGO
Etiqueta
1
RC9691020SMD
Amortiguador CP0016V
2
RC9161002SMD
Cerradura + llave
3
RC9483003SMD
Llave
4
RC99065
Sábanas protectoras
5
CN0020
Amortiguador CP0016VCS
6
RC9161003SMD
DESPIECE BÁSICO
www.mediclinics.com
-9-
Un adecuado mantenimiento preventivo y una cuidada limpieza son básicos para un uso idóneo, limpio y
seguro del producto.
Para un correcto mantenimiento se deben de seguir los siguientes pasos:
- Inspeccione los componentes del cambia pañales: asegúrese de que no existen grietas,
abolladuras o cualquier otro síntoma que haga pensar en el desperfecto del producto.
- Inspeccione la apertura del cambiador: abra y cierre la bandeja, verifique que no abre más de 90º
y que subiendo la bandeja una vez pasado 45º se cierra completamente de manera automática.
Los movimientos deben de ser suaves y continuos, de no ser así es posible que el amortiguador
no esté funcionando correctamente.
- Inspeccione la fijación a la pared: es uno de los puntos más importantes, asegúrese que sigue
firmemente fijado y que no hay juego o movimiento apreciable entre la parte fija del cambia
pañales y la pared.
- Inspeccione la fijación del dispensador sabanitas a la estructura metálica: abra la tapa del
dispensador y compruebe que los 4 tornillos de sujeción están bien apretados con sus arandelas
correspondientes.
RECOMENDACIONES DE MANTENIMIENTO PREVENTIVO Y LIMPIEZA
No deje nunca al niño desatendido sobre el cambia pañales.
Este cambia pañales está diseñado exclusivamente para bebés de
hasta 12 meses de edad y con un peso inferior a los 11kg.
Colocar paquetes y/o accesorios encima del cambia pañales puede
hacer que este se desestabilice.
- Inspeccione la etiqueta: si ésta no está, si se encuentra deteriorada, si no es legible o no está
bien adherida, debe poner una nueva.
Para una correcta limpieza se deben de seguir los siguientes pasos:
- Es aconsejable para evitar el contacto con el detergente que antes de limpiar se retiren las
sabanitas de su alojamiento.
- Limpie todas las piezas plásticas del cambia pañales con un jabón desinfectante.
- En el caso del modelo CP0016VCS, evite el contacto del jabón desinfectante con el frontal de
acero inoxidable, éste tiene que ser limpiado con un limpiador para acero inoxidable estándar y
un trapo suave.
- Retire los restos de jabón con un trapo seco, cerciorándose de que la limpieza ha sido efectiva y
que no quedan restos ni de suciedad ni de jabón.
- Una vez secado el cambia pañales vuelva a poner las sabanitas en su alojamiento y cierre la
tapa frontal con la cerradura.
- Haga una última inspección visual para comprobar que el cambia pañales está correctamente
limpio.
- Deje el cambia pañales en su posición de cerrado.
ADVERTENCIAS
www.mediclinics.com
-11-
VERY IMPORTANT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. READ AND KEEP IN
MIND ALL INSTRUCTIONS AND RECOMMENDATIONS DESCRIBED THROUGHOUT THIS MANUAL.
- Only a qualified technician can install, adjust and maintain this baby changing station. Any operations
performed on the changing station must be compliant with the safety laws and regulations, both
European and local, that are in force at the time. Mediclinics S.A. is not liable for damages caused by
the improper installation, poor maintenance or misuse of this baby changing station.
- It is very important that, once installed and put into operation, the baby changing station is periodically
inspected in order to ensure that it remains firmly secured to the wall and it has not suffered any
damage that may cause any harm to users. It is very important to make sure that the baby changing
station opens and closes properly.
- Any additional component or spare part required for the baby changing station should only be
purchased from the manufacturer or from an authorized distributor.
- Under no circumstances may the baby changing station be used if there are indications that any part of
it is broken, torn or lost.
- The baby changing station must be secured to a wall capable of withstanding the loads to which it will
be subjected daily without a problem and the most appropriate wall fixings must be used for each type
of wall.
- The total maximum recommended weight for this changing station is 11 kg and babies up to 12 months
acc. to EN 12221-1:2008+A1:2013 Type 1. The changing station has been tested with a load of 50 kg
during 1 hour according to the point 5.7 of the EN 12221-2:2008+A1:2013 Standard. Excessive weight
may create dangerous or unstable situations for the baby.
- All assembly joints and wall fixings must always be properly tightened and inspected regularly to make
sure that they are properly fastened.
- It is very important to install the changing station away from sources of heat or open fire in order to
avoid the risk of fire.
- If the changing station is vandalized, it is very important to remove it from the wall and perform a
thorough inspection of the unit and the wall where it should be installed in order to detect and solve any
problem that may lead to an accident.
- For better comfort and safety, sanitary liners should always be available in the changing station and the
unit should be thoroughly cleaned daily in order to minimize the spread of infectious diseases.
- Under no circumstance should the baby be left unattended at any time on top of the baby changing
station.
- Always place the baby in the centre of the changing station.
- The baby changing station is designed to be used without any pillow. Please do not use pillow or any
other device that could affect the baby placement on the changing station.
ENGLISH
SAFETY INSTRUCTIONS
BEFORE YOU BEGIN
Required tools
You will need the following tools for the installation of the baby changing station:
Fixings supplied
The following fixings are supplied with the baby changing station:
Six self-tapping Philips screws (DIN 7981/C A2 of
Ø6.3x70 mm) for fixing the changing station to the wall
Six Ø10mm nylon plugs to insert into the installation
holes of the changing station
Four flat washers (DIN125 M8 A2) to be mounted with
four Ø6.3x70 mm self-tapping Philips screws below the
metal structure
Four blunt Philips screws (DIN7985 A2 M4x8 mm) to
fasten the liner dispenser to the metal wall structure
Four flat washers (DIN125 M4 A2) to be mounted with
four blunt Philips screws (M4x8 mm) to fasten the liner
dispenser
INSTALLATION INSTRUCTIONS
www.mediclinics.com
-13-
Step 1. Material inspection
It is very important to carry out a visual inspection of the packaging of the baby changing station in order to
ensure that it has not suffered any damage during transport and handling. If damage to the packaging is
found, the changing station should be carefully inspected to see if it has suffered any damage. UNDER NO
CIRCUMSTANCE SHOULD THE BABY CHANGING STATION BE INSTALLED IF ANY DAMAGE IS
FOUND.
Remove all packaging material and check if any assembly component (bed with wall installation structure
and sanitary liner dispenser) or any hardware component (see table of fixings supplied) is missing.
Step 2. Preparation of the installation surface
Once the material is unpacked and inspected, choose the area on the wall where the baby changing
station will be installed. It is very important to keep in mind and respect the operating distances indicated in
the figure below, which are 75 mm on either side of the chassis for fixing the changing station to the wall
and 895 mm of the changing station bed, when it is open, from the wall.
The recommended installation height is 800 mm from the ground to the lowest part of the changing station.
The following sketch shows the height at which the holes should be made in order for the changing station
to be installed at the recommended height:
Following the above scheme, using the pencil, mark on the wall the top two holes of the changing station's
holding structure. It is very important to make sure that the locations marked with the pencil for the
mounting holes are at the same level before drilling the holes.
Installation according to ADA regulations.
If it is required that the installation complies with the ADA regulations (USA), the installation should be
made taking into account the following installation dimensions.
Step 3. Installation of the changing station's bed and holding structure on
the wall.
Installation on brick, masonry or cement wall.
Using the masonry bit, make the two previously marked Ø10 mm holes for the top part of the changing
station, at a minimum depth of 70 mm.
Clean the dust off the two holes and insert the two Ø10 mm nylon plugs into them.
Screw two of the Ø6.3x70 mm mounting screws into the two previously placed plugs, without reaching the
bottom, leaving a gap of about 5 mm between the screw head and the wall.
Hang the changing station's holding structure from the two previously placed screws, making sure that the
unit is perfectly levelled. When you have made sure that the changing station is perfectly levelled, tighten
the top two screws completely.
Use the four lower holes of the changing station's holding structure as a guide to mark the position of the
remaining four holes.
Loosen the upper screws and remove the changing station.
Using the previously made markings as reference, drill the four lower holes with the Ø10mm drill at a
minimum depth of 70 mm.
www.mediclinics.com
-15-
Once completed, proceed with cleaning the holes and placing the remaining four Ø10 mm nylon plugs.
Put the changing station back on the top two screws and fix the structure to the wall with the four Ø6.3x70
mm screws and the four DIN125 M8 washers of the lower holes, then fully tighten the top two screws, the
distribution of the components is shown in the following figure:
Make sure that the six screws securing the unit to the wall have been properly tightened and that the
changing station is firmly fixed to the wall.
Installation on plasterboard or hollow wall.
The fixing systems supplied with this changing station are not suitable for installation on
plasterboard or hollow walls.
In order to install the unit on this type of wall, fastening anchors and tools specific for plasterboard or
hollow walls must be used.
Due to the problems posed by installations on this type of walls, with regard to fixing, it is recommended
that the installation is carried out by technicians specialized in installations on this type of walls. Mediclinics
is not responsible for the installation of its changing stations on plasterboard or hollow walls.
Step 4. Mounting the liner dispenser on the changing station holding
structure
Take the liner dispenser and, after verifying that it is not damaged or scratched, place it on the metal
structure following the sequence of steps shown below and thus ensuring its proper position with the metal
shafts.
Open the liner dispenser with the special key provided. The four holes for mounting the liner dispenser on
the holding structure of the changing station will be visible.
Fit the dispenser to the holding structure of the changing station and align the mounting holes of the
dispenser.
Fix the liner dispenser to the holding structure of the changing station using the four M4x8mm screws and
the four DIN125 M4 flat washers, as shown in the figure. Check and make sure it has been properly fixed.
Step 5. Final revision before commissioning
Thoroughly clean and disinfect the baby changing station. It is very important to verify that the unit opens
and closes smoothly and that no damage has been caused during installation of the changing. In
summary, it is very important to verify, once the installation of the baby changing station is complete, that it
is in perfect condition to be used without any problems.
www.mediclinics.com
-17-
Remember that any additional component or spare part required for the baby changing station should
only be purchased from the manufacturer or an authorized distributor.
COMPONENT
No.
CODE
Label
1
RC9691020SMD
Shock absorber CP0016V
2
RC9161002SMD
Lock + key
3
RC9483003SMD
Key
4
RC99065
Protective liners
5
CN0020
Shock absorber CP0016VCS
6
RC9161003SMD
BASIC EXPLODED VIEW
Proper preventive maintenance and careful cleaning are essential for an appropriate, clean and safe
product use.
For proper maintenance, follow these steps:
- Inspect the components of the baby changing station: make sure that there are no cracks, dents
or any other sign that would suggest any fault in the product.
- Inspect the opening of the station: open and close the tray, make sure that it doesn't open beyond
90° and that when raising the tray, once past 45°, it automatically closes completely. The
movements should be smooth and continuous, otherwise it is possible that the shock absorber is
not functioning properly.
- Inspect the wall mounting: it is one of the most important points, make sure that it is firmly fixed
and that there are no gaps or significant movement between the fixed portion of the changing
station and the wall.
- Inspect the fastening of the liner dispenser to the metal structure: open the dispenser cover and
check that the 4 fixing screws are tightened with their respective washers.
- Inspect the label: if it is missing, damaged, illegible or not properly attached, a new one should be
placed.
RECOMMENDATIONS FOR PREVENTIVE MAINTENANCE AND
CLEANING
www.mediclinics.com
-19-
Never leave a child unattended on top of the baby changing station.
This changing station is designed exclusively for babies up to 12
months of age and weighing less than 11kg.
Placing packages and/or accessories on top of the changing station
can destabilize it.
-
For proper cleaning, follow these steps:
- In order to avoid contact with the detergent, it is recommended to remove the liners from their
housing before cleaning.
- Clean all plastic pieces of the changing station using antibacterial soap.
- On the CP0016VCS model, avoid contacting the stainless steel front with the antibacterial soap; it
has to be cleaned with a standard stainless steel cleaner and a soft cloth.
- Remove the soap residue with a dry cloth, making sure that the cleaning has been effective and
that there are no residues of dirt or soap.
- After the changing station has been dried, put the liners back in their housing and close the front
cover with the lock.
- Carry out a final visual inspection to make sure that the baby changing station has been properly
cleaned.
- Leave the changing station in a closed position.
WARNING
TRÈS IMPORTANT CONSERVEZ CES INSTRUCTIONS POUR DE FUTURES CONSULTATIONS.
LISEZ ATENTIVEMENT ET PRENEZ EN COMPTE TOUTES LES INSTRUCTIONS ET
RECOMMANDATIONS QUI SONT DÉCRITES TOUT AU LONG DE CE MANUEL.
- Seul un technicien qualifié peut installer, régler et réaliser l'entretien de cette table à langer. Toutes les
opérations qui sont réalisées sur celle-ci doivent respecter la législation et les normes de sécurité,
aussi bien européennes que locales, actuellement en vigueur. Mediclinics, S.A. n'est pas responsable
des dommages provenant d'une mauvaise installation ou utilisation ou d'un mauvais entretien de cette
table à langer.
- Il est primordial, une fois installée et prête à être utilisée, que cette table à langer soit régulièrement
inspectée pour vérifier la fixation ferme au mur et qu'elle ne souffre d'aucune imperfection qui puisse
causer des dommages aux utilisateurs. Il est très important de vérifier que la table à langer s'ouvre et
se ferme correctement.
- Chaque composant supplémentaire ou pièce de rechange nécessaire pour cette table à langer doit
être acquis uniquement chez un fabricant ou un distributeur autorisé.
- En aucun cas vous ne devez utiliser la table à langer en présence de signes qu'une des pièces de
cette dernière est cassée, déchirée ou manquante.
- La table à langer doit être fixée à un mur capable de supporter sans aucun problème les charges
auxquelles il sera soumis quotidiennement et les modes de fixation les mieux adaptés doivent s'utiliser
pour chaque type de mur.
- Le poids total maximal recommandé pour cette table à langer est de 11 kg et pour des enfants jusqu'à
12 mois selon la norme EN 12221-1:2008+A1:2013 de Type 1. La table à langer a été testée avec
succès avec une charge de 50 kg pendant 1 heure conformément au point 5.7 de la norme EN 12221-
2:2008+A1:2013. Un poids excessif peut créer des situations de danger ou d'instabilité pour bébé.
- Tous les raccords de montage et les fixations au mur doivent toujours être bien serrés et contrôlés
régulièrement afin de vérifier leur bonne fixation.
- Il est très important d'installer la table à langer loin des sources de chaleur ou de feux ouvert afin
d'éviter le risque d'incendie de l'unité.
- Si la table à langer souffre des dommages, il est extrêmement important de la démonter du mur et de
réaliser une inspection minutieuse de l'unité et du mur elle sera installée pour détecter et
solutionner tout problème pouvant entraîner un accident.
- Pour un meilleur confort et une sécurité augmentée, des draps hygiéniques doivent toujours être
disponibles sur la table à langer et l'unité doit être nettoyée à fond tous les jours pour réduire au
maximum la propagation de maladies infectieuses.
- Le bébé ne doit être laissé à aucun moment sans attention sur la table à langer.
- Toujours placer le bébé au centre de la table à langer.
- Cette dernière a été conçue pour être utilisée sans coussin. Veuillez ne pas utilisez de coussin ou tout
autre élément qui pourrait affecter la position de l'enfant sur la table à langer.
FRANÇAIS
INSTRUCTIONS DE SÉCURITÉ
AVANT DE COMMENCER
FRANÇAIS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Medicines P0016V Manuale utente

Tipo
Manuale utente