NOTE: Read carefully the MEMOR 11 User Manual
(available at www.datalogic.com) before performing any
type of connection to the MEMOR 11.
The user is responsible for any damage caused by
incorrect use of the equipment or by inobservance of the
indication supplied in the user manual.
GENERAL SAFETY RULES
CAUTION:
Before using the devices and the battery packs, read
this Addendum carefully.
Use only the components and accessories supplied
by the manufacturer for the specific MEMOR 11 being
used.
Do not attempt to disassemble the MEMOR 11 device,
as it does not contain parts that can be repaired by the
user. Any tampering will invalidate the warranty.
When replacing the battery pack or at the end of the
operative life of the MEMOR 11 device, disposal must
be performed in compliance with the laws in force in
your jurisdiction.
Do not submerge the MEMOR 11 in liquid products.
For further information or support, refer to the
Datalogic web site: www.datalogic.com.
CAUTION:
Do not apply any sticker to the MEMOR 11.
POWER SUPPLY
The device is intended to be supplied by a self-contained rechargeable
Lithium Ion battery pack (UL listed LPS/SELV power source) and/or by
UL Listed/CSA Certified Power Unit LPS/SELV power source which sup-
plies power directly to the unit via the TYPE-C USB connector of the
cable. The device could be also used with Certified Accessories (Dock/
Cradle) which supply Wireless power. The Dock/Cradle accessories are
intended to be supplied by a UL Listed/CSA Certified Power Unit LPS/
SELV which supplies power via the power connector of the cable. Any
changes or modifications to equipment, not expressly approved by
Datalogic could void the user’s authority to operate the equipment.
BATTERY INFORMATION
CAUTION: Do not incinerate, disassemble, short
terminals, or expose to high temperature. Risk of fire and
explosion. Use specified charger only. Risk of explosion
if the battery is replaced by an incorrect type. Dispose of
batteries as required by local authorities.
By default, the main battery pack is disconnected at the factory to avoid
damage due to excessive draining.
Rechargeable battery pack is less than half of full charge when deli-
ve-red. Charge the battery pack as indicated in the Quick Start Guide or
in the User Manual, before using the MEMOR 11 terminal.
The battery pack autonomy varies according to many factors, such as
the frequency of barcode scanning, RF usage, battery life, storage, envi-
ronmental conditions, etc.
To maximize battery life, turn off radios when they are not needed.
Close to the limits of the working temperature, some battery perfor-
mance degradation may occur.
The MEMOR 11 should be charged at an ambient temperature
between 20 - 35° C (68 to 122°F) to achieve the maximum
charging rate.
Never charge the device battery in a closed space where excessive
heat can build up. As a safety precaution, the battery may stop char-
ging to avoid overheating.
The MEMOR 11 gets warm during charging; this is normal and does
not mean a malfunction.
Even if the storage temperature range is wider, in order to achieve
the longest battery life, store the terminal and the spare batteries
between 20 to 30°C (68 to 86°F).
To maximize operating autonomy, the Memor 11 checks its battery
level at all times. If the battery is not sufficiently charged, the Memor
11 will not turn on when the ON/OFF Power button is pressed.
In this case, either substitute with a charged battery, insert the
Memor 11 into a powered cradle, or plug it into a wall charger.
CAUTION: Avoid storing batteries for long periods in a
state of full charge or very low charge or in a state of
continuous charging, especially at temperature higher
than 30°C.
We recommend charging the battery pack every two to
three months, if it is not used for long time, to keep its
charge at a moderate level to maximize battery life.
Annual replacement of rechargeable battery pack
avoids possible risks or abnormalities and ensures
maximum performance.
WARNING: Use only Datalogic approved batteries and
accessories for battery charging.
Risk of explosion if battery is replaced by an incorrect
type.
Dispose of used batteries according to the instructions.
Il y a risque d’explosion si la batterie est remplacée par
une batterie de type incorrect.
Mettre au rebut les batteris usagées confor mément
aux instructions.
CAUTION: Do not put any foreign object such as, but not
limited to, coins, paper clips, stickers inside the slot of
any of the wireless charging docks (see the examples
below).
BATTERY SAFETY GUIDELINES
WARNING: Installing, charging and/or any other action
should be done by authorized personnel and following
this manual.
The battery pack may get hot, explode, ignite, and/or
cause serious injury if exposed to abusive conditions.
If the battery pack is replaced with an improper type,
there is risk of explosion.
Do not place the battery pack in or near a fire or
other heat source; do not place the battery pack in
direct sunlight, or use or store the battery pack inside
unventilated areas in hot weather; do not place the
battery pack in microwave ovens, in clothes dryers, in
high pressure containers, on induction cook surfaces or
similar devices. Doing so may cause the battery pack to
generate heat, explode or ignite. Using the battery pack
in this manner may also result in a loss of performance
and a shortened life expectancy.
MEMOR™ 11
SAFETY & REGULATORY
ADDENDUM
Rugged Mobile Computer
with 1D/2D Imager
• All rights reserved • Without limiting
the rights under copyright, no part of this
documentation may be reproduced, stored
in or introduced into a retrieval system, or
transmitted in any form or by any means,
or for any purpose, without the express
written permission of Datalogic S.p.A.
and/or its affiliates • Datalogic and the
Datalogic logo are registered trademarks
of Datalogic S.p.A. in many countries,
including the U.S. and the E.U.
This document is an addendum to the
Quick Start Guide (QSG) for this product.
See the QSG for additional product
information.
www.datalogic.com
©2023 Datalogic S.p.A. and/or its affiliates
852002170 (Rev. A) March 2023
Datalogic S.r.l.
Via San Vitalino 13
40012 Calderara di Reno (BO)
Italy
Tel. +39 051 3147011
Fax +39 051 3147205
©2023 Datalogic S.p.A. and/or its affiliates
All rights reserved. Without limiting the rights under copyright, no part of this documentation may be repro-
duced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and tran-
smit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or
alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure
that all notices appear on any reproductions of the documentation.
Electronic versions of this document may be downloaded from the Datalogic website (www.datalogic.com).
If you visit our website and would like to make comments or suggestions about this or other Datalogic publi-
cations, please let us know via the "Contact" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accu-
rate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor
for incidental or consequential damages resulting from the use of this material. Datalogic reserves the right
to change any specification at any time without prior notice.
Trademarks
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including
the U.S.A. and the E.U.
Memor is a trademark of Datalogic S.p.A. and/or its affiliates. All other brand and product names may be
trademarks of their respective owners.
Patents
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Design patents: EM004675072, EM004803013, EM005513751 0001/0002, GB9004675072 0001/0002,
GB9004803013 0001/0002, GB9005513751 0001/0002, USD933062, ZL201830392430.1, ZL201930042130.5
Utility patents: EP1804089B1, EP1825417B1, EP1828957B1, EP2315156B1, EP2517148B1, EP2521068B1,
EP2616988B1, EP2649555B1, EP2795534B1, EP3234750B1, JP5192390B2, US10671277, US10762405,
US10817685, US7234641, US7721966, US8113430, US8245926, US8561906, US8888003, US8915443,
US9122939, US9430689, US9798948, ZL200680050007.8, ZL200980163411.X, ZL201080071124.9,
ZL201180044793.1, ZL201580074380.6.
WEEE STATEMENT
Waste Electrical and Electronic Equipment (WEEE) Statement
English
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the
website at www.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web
www.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques (WEEE), veuillez consulter le site
internet www.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE) erhalten Sie auf der Webseite
www.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y
electrónico (WEEE), visite la página Web www.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste
Electrical and Electronic Equipment), consultar o site web www.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考Datalogic 公司的网站 www.datalogic.com.
Japanese
廃電気電子機器(WEEE)の処理についての関連事項はDatalogicのサイト www.datalogic.com をご
参照下さい。.
WARNING: To power the cradle, use only a Datalogic approved power supply. The
use of an alternative power supply will void the product warranty, may cause product
damage and may cause heat, an explosion, or fire.
The area in which the units are charged should be clear of debris and combustible
materials or chemicals.
Do not use the battery pack of this terminal to power devices other than this device.
Avoid storing batteries for long periods in a state of continuous charging, full charge
or very low charge, especially at temperature higher than 30°C.
Periodically check the battery status and immediately discontinue use of the battery
pack if, while using, charging or storing the battery pack, the battery pack emits an
unusual smell, feels hot, changes colour or shape, swelling or appears abnormal in
any other way.
Do not short-circuit the battery pack contacts connecting the positive terminal and
negative terminal. This might happen, for example, when you carry a spare battery
pack in your pocket or purse; accidental short-circuiting can occur when a metallic
object such as a coin, clip, or pen causes direct connection of the contacts of the
battery pack (these look like metal strips on the battery pack). Short-circuiting the
terminals may damage the battery pack or the connecting object.
Do not apply voltages to the battery pack contacts.
Do not pierce the battery pack with nails, strike it with a hammer, step on it or
otherwise subject it to strong impacts, pressures, or shocks.
Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The
battery pack contains safety and protection devices, which, if damaged, may cause
the battery pack to generate heat, explode or ignite.
In case of leakage of liquid from the battery, avoid contact with liquid the skin or
eyes. If the contact occurs, immediately wash the affected area with water and
consult a doctor.
Do not solder directly onto the battery pack.
Do not expose the battery pack to liquids.
Avoid any knocks or excessive vibrations. If the device or the battery is dropped,
especially on a hard surface, you should take it to the nearest Authorised Repair
Centre for inspection before continuing to use it.
If your device stops working for any reason, do not use its battery on other electronic
devices without a prior check and approval by an Authorised Repair Centre.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Collect and recycle waste batteries separately from the device in compliance with
European Directive 2013/56, 2011/65, 2012/79 and subsequent modifications, with
US and China regulatory laws and regulations about the environment.
WIRELESS AND RADIO FREQUENCIES WARNINGS
WARNING: Most modern electronic equipment is shielded from RF signals. However,
certain electronic equipment may not be shielded against the RF signals generated
by MEMOR 11.
Datalogic recommends persons with pacemakers or other medical devices to follow
the same recommendations provided by Health Industry Manufacturers Associations
for mobile computers.
Persons with pacemakers:
Should ALWAYS keep this device more than twenty five (25) cm from their
pacemaker and/or any other medical device;
Should not carry this device in a breast pocket;
Should keep the device at the opposite side of the pacemaker and/or any other
medical device;
Should turn this device OFF or move it immediately AWAY if there is any reason
to suspect that interference is taking place.
Should ALWAYS read pacemaker or any other medical device guides or should
consult the manufacturer of the medical device to determine if it is adequately
shielded from external RF energy.
In case of doubt concerning the use of wireless devices with an implanted medical
device, contact your doctor.
Turn this device OFF in health care facilities when any regulations posted in these
areas instruct you to do so. Hospitals or health care facilities may use equipment
that could be sensitive to external RF energy.
WARNING: RF signals may affect improperly installed or inadequately shielded
electronic systems in motor vehicles. Check with the manufacturer or its
representative regarding your vehicle. You should also consult the manufacturer of
any equipment that has been added to your vehicle.
An air bag inflates with great force. DO NOT place objects, including either installed
or portable wireless equipment, in the area over the air bag or in the air bag
deployment area. If a vehicles wireless equipment is improperly installed and the
air bag inflates, serious injury could result.
Turn off the device when in any area with a potentially explosive atmosphere.
Observe restrictions and follow closely any laws, regulations, warnings and best
practices on the use of radio equipment near fuel storage areas or fuel distribution
areas, chemical plants or where any operation involves use of explosive materials.
Do not store or carry flammable liquids, explosive gases or materials with the device
or its parts or accessories.
Areas with a potentially explosive atmosphere are oen, but not always, clearly
marked or shown.
Sparks in such areas could cause an explosion or fire, resulting in injury or even
death.
LED CLASS
LED illuminator integrated in the imager engine is classified as RISK GROUP 1 according to
IEC62471.
LASER SAFETY
The following information applies to Laser Aiming System, used on MEMOR 11. The laser light is
visible to the human eye and is emitted from the window indicated in the figure below.
LASER RADIATION - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX OUTPUT RADIATION 1 mW
COMPLIANT WITH EN 60825-1 (2014)
NOTE: The artwork below may be only a dra. Please refer to the label attached to
the product for information about certification marks.
Use careful with the earphone maybe possible excessive sound pressure from
earphones and headphones can cause hearing loss.
CAUTION: The device shall only be connected to a USB interface of version USB
TYPE-C.
Adapter shall be installed near the equipment and shall be easily accessible.
The device should operating at temperature between -20-50 °C.
RF Exposure Information and Statement:
This device was tested for hand-held and body-worn conditions, according to international Stan-
dards covering human exposure to electromagnetic fields from radio devices. The SAR limit of EU
(CE) is 2.0 W/kg for trunk/head as averaged over any 10g tissue according to the EN 50360:2017
and EN 50566:2017. MEMOR 11 has also been tested against this SAR limit. The highest SAR
value reported under this standard during product certification for use at the ear is 0.55 W/kg
and when properly worn on the body is 1.03 W/kg. This device was tested for typical body-worn
operations. A minimum separation distance must be maintained between the user’s body and the
handset, including the antenna:5mm to comply with the RF exposure requirements in Europe.
Third-party belt-clips, holsters and similar accessories used by this device should not contain
any metallic components. Body-worn accessories that do not meet these requirements may not
comply with RF exposure requirements and should be avoided.
MARKING AND EUROPEAN ECONOMIC AREAEEA
In radio systems configured with mobile computers and access points, the frequencies to be used
must be allowed by the spectrum authorities of the specific country in which the installation takes
place. Be absolutely sure that the system frequencies are correctly set to be compliant with the
spectrum requirements of the country.
The Radio modules used in this product automatically adapt to the frequencies set by the system
and do not require any parameter settings.
European Declaration of Conformity
Hereby, Datalogic S.r.l. declares that this radio equipment is in compliance with Directive 2014/53/
EU. The full text of the EU declaration of conformity is available at: www.datalogic.com. Select
the Support & Service > Downloads > Product Certifications link where you can search for your
specific product certification.
Česky [Czech]
Tímto Datalogic S.r.l. prohlašuje, že toto rádiové zařízení je ve shodě se směrnicí 2014/53/EU.
Dansk [Danish]
Herved erklæres Datalogic S.r.l. erklærer, at dette radioudstyr er i overensstemmelse med
direktiv 2014/53/EU.
Deutsch [German]
Hiermit wird Datalogic S.r.l. erklärt, dass dieses Funkgerät der Richtlinie 2014/53/EU entspricht.
Eesti [Estonian]
Käesolevaga on Datalogic S.r.l. kinnitab, et see raadioseade on kooskõlas direktiiviga 2014/53/
EL.
Español [Spanish]
Por la presente, Datalogic S.r.l. declara que este equipo de radio cumple con la Directiva 2014/53/
UE.
Ελληνική [Greek]
Με το παρόν, Datalogic S.r.l. δηλώνει ότι αυτός ο ραδιοεξοπλισμός συμμορφώνεται με την Οδηγία
2014/53/ΕΕ.
Français [French]
Par la présente, Datalogic S.r.l. déclare que cet équipement radio est conforme à la directive
2014/53/UE.
Italiano [Italian]
Con la presente Datalogic S.r.l. dichiara che questa apparecchiatura radio è conforme alla Direttiva
2014/53/UE.
Latviski [Latvian]
Ar šo Datalogic S.r.l. paziņo, ka šī radioiekārta atbilst Direktīvai 2014/53 / ES.
Laser Warning Label
Laser Aperture/Ouverture Laser
ITALIANO DEUTSCH FRANÇAIS ESPAÑOL
LA LUCE LASER È VISI-
BILE ALL’OCCHIO UMANO
E VIENE EMESSA DALLA
FINESTRA INDICATA
NELLA FIGURA.
DIE LASER-STRAHLUNG
IST FÜR DAS MEN-
SCHLICHE AUGE
SICHTBAR UND WIRD AM
STRAHLAUS TRITTSFEN-
STER AUSGESENDET
(SIEHE BILD).
LE RAYON LASER EST
VISIBLE À L’OEIL NU
ET IL EST ÉMIS PAR LA
FENÊTRE DÉSIGNÉE SUR
L’ILLUSTRATION DANS
LA FIGURE.
A LUZ LÁSER ES VISIBLE
AL OJO HUMANO Y ES
EMITIDA POR LA VEN-
TANA INDICADA EN LA
FIGURA.
LUCE LASER NON FIS-
SARE IL FASCIO
APPARECCHIO LASER
DI CLASSE 2 MASSIMA
POTENZA D’USCITA: 1
mW
LUNGHEZZA D’ONDA
EMESSA: 630~680 nm
CONFORME A EN
60825-1 (2014).
LASERSTRAHLUNG
NICHT IN DEN STRAHL
BLICKEN PRODUKT
DER LASERKLASSE 2
MAXIMALE AUSGANG-
SLEISTUNG: 1 mW
WELLENLÄGE: 630~680
nm
ENTSPR. EN 60825-1
(2014).
RAYON LASER EVITER DE
REGARDER LE RAYON
APPAREIL LASER DE
CLASSE 2 PUISSANCE DE
SORTIE: 1 mW
LONGUEUR D’ONDE
EMISE: 630~680 nm
CONFORME A EN
60825-1 (2014).
RAYO LÁSER NO MIRAR
FIJO EL RAYO APARATO
LÁSER DE CLASE 2
MÁXIMA POTENCIA DE
SALIDA: 1 mW
LONGITUD DE ONDA
EMITIDA:
630~680 nm
CONFORME A EN
60825-1 (2014).
Lietuvių [Lithuanian]
Šiuo dokumentu „Datalogic S.r.l.“pareiškia, kad ši radijo įranga atitinka Direktyvą 2014/53/ES.
Nederlands [Dutch]
Hierbij verklaart Datalogic S.r.l. dat deze radioapparatuur voldoet aan Richtlijn 2014/53/EU.
Malti [Maltese]
Hawnhekk, Datalogic S.r.l. tiddikjara li dan it-tagħmir tar-radju huwa konformi mad-Direttiva
2014/53/UE.
Magyar [Hungarian]
A Datalogic S.r.l. kijelenti, hogy ez a rádióberendezés megfelel a 2014/53/EU irányelvnek.
Polski [Polish]
Niniejszym Datalogic S.r.l. oświadcza, że to urządzenie radiowe jest zgodne z Dyrektywą 2014/53/
UE.
Português [Portuguese]
Por meio deste, a Datalogic S.r.l. declara que este equipamento de rádio está em conformidade
com a Diretiva 2014/53/UE.
Slovensko [Slovenian]
Datalogic S.r.l. izjavlja, da je ta radijska oprema v skladu z Direktivo 2014/53/EU.
Slovensky [Slovak]
Týmto spoločnosť Datalogic S.r.l. vyhlasuje, že toto rádiové zariadenie je v súlade so smernicou
2014/53 / EÚ.
Suomi [Finnish]
Datalogic S.r.l. vakuuttaa täten, että tämä radiolaite on direktiivin 2014/53 / EU mukainen.
Svenska [Swedish]
Datalogic S.r.l. förklarar härmed att denna radioutrustning överensstämmer med direktiv 2014/53
/ EU.
UKCA Declaration of Conformity
Hereby, Datalogic S.r.l. declares that this radio equipment is in compliance with the Radio
Equipment Regulations (RER) (S.I. 2017/1206) and that the full text of the UKCA Declaration of
Conformity is available at the following internet address: http://www.datalogic.com. Select the
Support & Service > Downloads > Product Certifications link where you can search for your spe-
cific product certification.
NBTC Statement
เครื่องโทรคมนาคมและอุปกรณ์นี้ มีความสอดคล้องตามข้อกำาหนดของ กทช.
This telecommunication equipment is in compliance with NTC requirements.
INFORMATION FOR THE USER
ENGLISH
Contact the competent authority responsible for the management of radio frequency devices of
your country to verify any possible restrictions or licenses required.
ITALIANO
Prendi contatto con l’autorita competente per la gestione degli apparati a radio frequenza del tuo
paese, per verificare eventuali restrizioni o licenze.
DEUTSCH
Wenden Sie rich an die fur Radiofrequenzgerate zustandige Behorde lhres Landes, um zu prufen
ob es Einschrankungen gibt, oder eine Lizenz erforderlich ist.
FRANÇAIS
Contactez l’autorite competente en la gestion des appareils a radio frequence de votre pays pour
verifier d’eventuelles restrictions ou licences.
ESPAÑOL
Contacta la autoridad competente para la gestion de los dispositivos de radio frecuencia de to
pais, para verificar cualesquiera restricciones o licencias posibles requerida.
CAUTION: This device has been tested and found to comply with the limits pursuant
to EN 303 417. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to other electronic equipment,
which can be determined by turning the equipment OFF and ON, the user is
encouraged to try to correct the interference by one or more following measures:
Reorient or relocate the equipment
Increase the separation
Don’t place some metal things between the TX surface and the RX surface, Otherwise
the metal things will be heated, and therefore the temperature might get high.
RADIO TECHNOLOGIES AND FREQUENCY BANDS
Compliance with 2014/53/EU Radio Equipment Directive (RED). In accordance with Article
10.8(a) and 10.8(b) of the RED and RER - S.I. 2017/1206 Article 13.2(a) and 13.2(b). The following
table provides information on the frequency bands used and the maximum RF transmit power of
the product for sale in the Europe.
Radio
Technology
Transmit
Frequency
Transmit Power Receive Frequency
GSM 900 880MHz to 915MHz 33 dBm 925MHz to 960MHz
GSM1800 1710MHz to 1785MHz 30 dBm 1805MHz to 1880MHz
WCDMA bandI 1920MHz to 1980MHz 23.5 dBm 2110MHz to 2170MHz
WCDMA bandV 824MHz to 849MHz 23.5 dBm 869MHz to 894MHz
WCDMA bandVIII 880MHz to 915MHz 23.5 dBm 935MHz to 960MHz
LTE FDD1 1920MHz to 1980MHz 23 dBm 2110MHz to 2170MHz
LTE FDD3 1710MHz to 1785MHz 23 dBm 1805MHz to 1880MHz
LTE FDD5 824MHz to 849MHz 23.5 dBm 869MHz to 894MHz
LTE FDD7 2500MHz to 2570MHz 22 dBm 2620MHz to 2690MHz
LTE FDD8 880MHz to 915MHz 23.5 dBm 925MHz to 960MHz
LTE F DD20 832MHz to 862MHz 23.5 dBnn 791 MHz to 821 MHz
LTE FDD28 703MHz to 748MHz 24.5 dBnn 758MHz to 803MHz
LTE TDD38 2570MHz to 2620MHz 23 dBm 2570MHz to 2620MHz
LTE TDD40 2300MHz to 2400MHz 23 dBm 2300MHz to 2400MHz
LTE TDD41 2496MHz to 2690MHz 23 dBm 2496MHz to 2690MHz
BT 5.2 2402MHz to 2480MHz 8.3 dBm EIRP 2402MHz to 2480MHz
BLE 2402MHz to 2480MHz -1.8 dBm EIRP 2402MHz to 2480MHz
2.4G wifi 2412MHz to 2472MHz 20 dBm EIRP 2412MHz to 2472MHz
5G wifi 5180MHz to 5320MHz 23 dBm EIRP 5180MHz to 5320MHz
5G wifi 5500MHz to 5700MHz 20 dBm EIRP 5500MHz to 5700MHz
5G wifi 5725MHz to 5850MHz 14 dBm EIRP 5725MHz to 5850MHz
NFC 13.56MHz / 13.56MHz
WLC RX / / 119KHz to 140KHz