BADU Profi-MK Eco VS Istruzioni per l'uso

Tipo
Istruzioni per l'uso

Questo manuale è adatto anche per

03|2022
DE Pumpendatenblatt
EN Pump data sheet
FR Fiche technique pompe
NL Pompgegevens
IT Documentazione pompa
ES Ficha técnica de la bomba
Profi Eco VS
W90.13.000-5-P
2 03|2022
BADU® ist eine Marke der
SPECK Pumpen Verkaufsgesellschaft GmbH
Hauptstraße 3
91233 Neunkirchen am Sand, Germany
Telefon 09123 949-0
Telefax 09123 949-260
info@speck-pumps.com
www.speck-pumps.com
Alle Rechte vorbehalten.
Inhalte dürfen ohne schriftliche Zustimmung von SPECK Pumpen
Verkaufsgesellschaft GmbH weder verbreitet, vervielfältigt, bearbeitet
noch an Dritte weitergegeben werden.
Dieses Dokument sowie alle Dokumente im Anhang unterliegen keinem
Änderungsdienst!
Technische Änderungen vorbehalten!
03|2022 3
21,5
588
673
10
133,5 267,5
357
260
225
348,5
11,5
162
max. L
Sa
Da
~100
~300
W90.13.000-4-P
4 03|2022
TD 50 Hz
Sa [mm]
Da [mm]
d-Saug
[mm]
d-
Druck
[mm]
max. L
[mm]
BADU Profi Eco VS
75
75
63
63
690
1~ 230 V
TD 50 Hz
n [min
-1]
P1 [kW]
P2 [kW]
I [A]
Lpa
(1m)
[dB(A)]
Lwa
[dB(A)]
m [kg]
WSK/PTC
BADU Profi Eco VS
1000
0,09
0,03
0,64
40,0
48
17,0
●/○
BADU Profi Eco VS
3000
1,80
1,40
7,80
69,7
78
17,0
●/○
TD 50 Hz
n [min
-1]
Hmax. [m]
SP
Hs [m]
Hz [m]
IP
W-Kl
T [°C]
P-GHI
[bar max.]
BADU Profi Eco VS
1000
1,90
3
3
55
F
40(60)
2,5
BADU Profi Eco VS
3000
16,6
3
3
55
F
40(60)
2,5
03|2022 DE 5
DE Pumpendatenblatt
Mitgeltende Dokumente
Zu diesem Pumpendatenblatt gehört die
Originalbetriebsanleitung "Normal- und selbstansaugende
Pumpen mit/ohne Kunststofflaternen-Ausführung (-AK)". Sie
muss für das Bedien- und Wartungspersonal frei zugänglich
sein.
Profi Eco VS
W90.13.000-5-P
DE 6 03|2022
Glossar
TD
Technische Daten
Sa
Sauganschluss
Da
Druckanschluss
d-Saug
Empfohlener Durchmesser der Saugleitung bis 5 m
d-Druck
Empfohlener Durchmesser der Druckleitung bis 5 m
max. L
Maximale Länge der Pumpe
D
Dichte
P1
Aufgenommene Leistung
P2
Abgegebene Leistung
I
Nennstrom
Lpa (1 m)
Schalldruckpegel in 1 m Entfernung gemessen nach DIN 45635
Lwa
Schallleistung
m
Gewicht
WSK
Wicklungsschutzkontakt oder Motorschutzschalter
PTC
Kaltleiter
Hmax.
Maximale Förderhöhe
SP
Selbstansaugend
Hs; Hz
Geodätische Höhe zwischen Wasserspiegel und Pumpe
Hs
Maximale Saughöhe
Hz
Maximale Höhe bei Zulaufbetrieb
IP
Schutzart des Motors
W-Kl
Wärmeklasse
n
Drehzahl
P-GHI
2,5 bar max. Gehäuseinnendruck/max. Systemdruck
T
Wassertemperatur
Ja
Nein
T/°C
Erläuterung Wassertemperatur 40 °C (60 °C): 40 °C = gilt für
maximale Wassertemperatur im Sinne des GS-Zeichens. (60 °C) =
Pumpe ist ohne weiteres für eine maximale Wassertemperatur von
60 °C einsetzbar/ausgelegt.
1~/3~
Geeignet für Dauerbetrieb bei
1~ 220 - 240 V ± 5%
3~ Y/∆ 380 - 420 V/220 - 240 V ± 5%
3~ Y/∆ 660 - 725 V/380 - 420 V ± 5%
Für Normspannung geeignet nach DIN IEC 60038; DIN EN 60034
03|2022 DE 7
Die Pumpe besitzt einen Permanentmagnet-Motor und ist elektronisch vor
Überlastung gesichert.
Anschluss externer Schaltkontakte
Zur externen Ansteuerung besitzt die Pumpe ein 5-adriges Kabel mit
offenen Enden. Zuordnung der Kabel zu den einzelnen Drehzahlen wie
folgt:
Die Kabel sind potentialfrei anzuschließen. Kontakte nur einzeln
schalten (Priorität der Kontakte beachten), ansonsten erfolgt keine
Aktivierung der gewünschten Drehzahl.
HINWEIS
Einschalten der Motordrehzahl mittels Handtaster oder externer
Schaltkontakte. Dadurch Aktivierung der Schaltkontakte und der
zugeordneten Drehzahl.
Startet die Pumpe aus dem
Stillstand heraus, läuft sie im Ansaugmodus
an und anschließend mit der ausgewählten Festdrehzahl.
Im laufenden Betrieb werden die Festdrehzahlen direkt angefahren, ohne
Ansaugzeit.
Wird die externe Ansteuerung nicht benötigt, müssen die Kabelenden
isoliert werden.
HINWEIS
Für das problemlose Zusammenspiel mit Peripheriegeräten, wie z.B.
Elektrowärmetauscher oder Dosieranlage
n, wird der Einbau eines
Strömungswächters mit entsprechender Auswerteeinheit empfohlen.
Damit kann auch eine Störmeldung ausgegeben werden.
DE 8 03|2022
HINWEIS
Um Fehlfunktionen im Motor zu vermeiden, müssen folgende Punkte
unbedingt beachtet werden:
Die Steuerleitung muss fachlich korrekt verlegt werden. Eine
Montage parallel zur eigenen Netzleitung oder
anderen Verbrauchern
muss vermieden werden.
Sollten die Steuerleitungen verlängert werden, können gefährliche
Spannungen am Digitaleingang entstehen. Diese müssen zum
Beispiel durch Abschirmung verhindert werden.
Die Netzkabel verschiedener Betriebsmittel nicht am gleichen
Versorgungsstrang betreiben.
Voreinstellung:
Geschwindigkeit:
Ansauggeschwindigkeit:
Ansaugzeit:
Einstellbare Geschwindigkeit:
Einstellbare Ansaugzeit:
Externe Ansteuerung:
Schaltverhalten Eingang „0“:
1 = 2000 min-1
2 = 2400 min-1
3 = 2850 min-1
= 2850 min-1
= 5 Minuten
1000 3000 min-1 (in 10 min-1
Schritten)
oFF, 1 10 Min. (in 1 Min. Schritten)
oFF
0 cl
Priorit
Niedrig
n1
Hoch
Stopp
WG27.50.094-1-P
n2 n3
03|2022 DE 9
Bedienoberfläche:
(1) LED-Display: zeigt die aktuelle Drehzahl
des Motors an.
(2) : Auswahl der voreingestellten
Drehzahlen
(3) : Zur Anzeige des aktuellen
Verbrauchs und Auswahl der Parameter
im Setup
(4) : Zum Einstellen der Parameter
(5) : zum Ändern der Drehzahl
(6) : zum Stoppen des Motors
Beim Zuschalten der Netzspannung erscheint kurzzeitig im Display die
Softwareversion "-rX.X-"
Bedienung:
Taste oder drücken, um die voreingestellte
Drehzahl auszuwählen.
Startet die Pumpe aus dem Stillstand heraus, läuft sie
im Ansaugmodus an (sofern dieser aktiviert) und
anschließend mit der ausgewählten Festdrehzahl.
Solange sich die Pumpe in der Ansaugphase befindet,
wandert an der ersten Stelle im Display ein Balken von
der unteren, über die mittlere zur oberen Position.
Im laufenden Betrieb werden die Drehzahlen direkt
angefahren, ohne Ansaugzeit.
Durch Drücken der Taste wird der Motor gestoppt.
Die "Power"-LED blinkt und das Display zeigt "oFF"
an.
Einstellen der Drehzahlen:
Die Taste der Festdrehzahl die verändert werden soll
drücken ( , oder ) und danach mit den Tasten
die Drehzahl ändern. Die eingestellte Drehzahl
wird direkt gespeichert und bei erneuter Auswahl der
Festdrehzahl angefahren.
Hinweis: Während der Ansaugphase kann die Drehzahl nicht
verändert werden.
WG27.50.006-P
4
6
5
1
2
3
WG27.50.007-P
WG27.50.008-P
DE 10 03|2022
Einstellen der Parameter:
Durch Drücken der Taste für 3 Sekunden wird in
das Setup-Menü gewechselt. Dort kann mit der -
Taste durch das Menü geblättert werden.
Die erste Stelle des Displays zeigt den aktuellen
Menüpunkt an und die restlichen vier Stellen den
einzustellenden Parameter.
Wird die Taste innerhalb des Menüs gedrückt, dann
werden alle geänderten Werte gespeichert und das
Setup-Menü verlassen, der Text "StorE" wird im
Display angezeigt.
Durch Drücken der Taste wird das Setup-Me
ohne Speicherung der geänderten Werte verlassen.
Ansaugparameter:
Unter dem Menüpunkt "n" wird die Drehzahl und unter
dem Punkt "t" wird die Zeit während der Ansaugphase
eingestellt.
"t oFF" = keine Ansaugphase
von oFF, 1 - 10 Minuten
Digitaleingänge:
Bei dem Menüpunkt "E" kann die externe
Ansteuerung aktiviert bzw. deaktiviert werden.
"oFF" = deaktiviert
"dl" = Digitaleingänge (potentialfrei) aktiviert
Schaltverhalten "0" (Stopp):
Unter dem Punkt "0" kann das Schalt-verhalten des
Digitaleingangs "0" geändert (invertiert) werden.
"cL" bedeutet, der Antrieb wird bei geschlossenem
Kontakt gestoppt.
"oP" bedeutet, der Antrieb wird bei offenem Kontakt
gestoppt.
Zurücksetzen / Reset:
Wird die -Taste für mindestens 10 Sekunden
gedrückt, dann wird der Antrieb auf die
Werkseinstellungen zurückgesetzt. Der Motor stoppt
und im Display steht "rESEt".
WG27.50.009-P
WG27.50.010-P
WG27.50.011-P
WG27.50.012-P
WG27.50.013-P
03|2022 DE 11
Durch Drücken der -Taste wird im Display der
aktuelle Leistungsbedarf der Pumpe in Watt angezeigt
(P XXX).
Das Display der Steuerung schaltet sich nach drei
Minuten ohne Aktion ab.
Die Pumpe läuft nach einem Spannungsverlust automatisch wieder mit
der zuletzt eingestellten Drehzahl an oder bleibt stehen, wenn sie zuvor
gestoppt wurde.
Das Ein- und Ausschalten der Pumpe sollte über das dafür vorgesehene
Steuerkabel (potentialfreie Kontakte) realisiert werden. Dies kann über
eine BADU-Logic-Steuerung, BADU OmniTronic oder über ein kleines
Koppelrelais geschehen. Dadurch wird die Elektronik weniger belastet.
Übersicht möglicher Betriebs- und Fehlermeldungen
Ist ein Fehler aufgetreten, schaltet der Motor dauerhaft ab und es wird
eine Fehlermeldung angezeigt. Ausnahme: "Unterspannung" beim Ausfall
oder Abschalten der Netzversorgung. Bei diesem Fehler startet der
Antrieb beim nächsten Zuschalten der Netzspannung neu.
Tritt ein Defekt auf, so ist die Anlage von der Spannungsversorgung zu
trennen. Siehe Kapitel 2.2 der Originalbetriebsanleitung "Normal und
selbstansaugende Pumpe mit/ohne Kunststofflaternen-Ausführung (-AK)".
Fehler-Nr.
Beschreibung
Err 1
Unterspannung Zwischenkreis
Err 2
Überspannung Zwischenkreis
Err 3
Netzspannung zu niedrig / zu hoch
Err 4
Temperatur an Leistungselektronik zu hoch
Err 5
Übertemperatur Motor
Err 7
Überstrom Elektronik
Err 10
Strommessung fehlerhaft
Err 20
Abbruch beim Anlauf, Überlastung
Err 64
Kurzschluss Elektronik
Err 97
Gleichzeitiges Auftreten mehrerer Fehler
Err 98
Verbindung zum Bedienteil fehlerhaft
WG27.50.014-P
DE 12 03|2022
Deckel/Saugsieb demontieren bzw. montieren
Batteriewechsel im Klarsichteinsatz
1. Pumpe ausschalten.
2. Absperrarmaturen schließen.
3. Deckel abnehmen.
4. Den kleinen Deckel (1) mit den beiden Stiften (2) der Öffnungshilfe
abschrauben.
5. Einsatz herausnehmen.
6. LED nach unten aus dem Einsatz herausdrücken.
7. Austausch der Batterien. 2x Typ CR2032, 3V
Auf Pole (+/-) achten!
8. Montage in umgekehrter Reihenfolge.
W72.40.007-1-P
1
2
3
W90.04.100-P
(1)
(2)
03|2022 EN 13
EN Pump data sheet
Related Documentation
The additional information compiled in this data sheet must be
kept together with the original operation manual for "Non-self-
priming and self-priming pumps with/without plastic lanterns"
and must be accessible to the relevant personnel at all times.
Profi Eco VS
W90.13.000-5-P
EN 14 03|2022
Glossary
TD
Technical data
Sa
Inlet connection
Da
Outlet connection
d-Saug
Recommended diameter for the suction line from 5 m
d-Druck
Recommended diameter for the pressure line from 5 m
max. L
Maximum length of the pump
D
Density
P1
Power input
P2
Power output
I
Rated current
Lpa (1 m)
Sound pressure level at 1 m measured in accordance with DIN 45635
Lwa
Acoustic capacity
m
Weight
WSK
Built-in or external overload switch
PTC
PTC resistor
Hmax.
Total dynamic head
SP
Self-priming
Hs; Hz
Geodetic head between water level and pump
Hs
Total suction head
Hz
Total dynamic head with flooded suction
IP
Type of motor enclosure
W-Kl
Class of insulation
n
Motor speed
P-GHI
2.5 bar max. casing pressure/system pressure
T
Water temperature
Yes
No
T/°C
Clarification of the max. water temperature 40 °C (60 °C): 40 °C = the
max. water temperature allowed according to the GS approval.
(60 °C) = the pump is designed to withstand a max. water
temperature of 60 °C.
1~/3~
Suitable for continuous operation at
1~ 220 - 240 V ± 5%
3~ Y/∆ 380 - 420 V/220 - 240 V ± 5%
3~ Y/∆ 660 - 725 V/380 - 420 V ± 5%
For standard voltage in accordance with DIN IEC 60038;
DIN EN 60034
03|2022 EN 15
The pump has a permanent magnetic motor and is electronically
protected against overload.
Connecting external switch contacts
The pump has a 5-wire cable with open ends for external control.
Assignment of the cables to the individual speeds is as follows:
The cables must be connected potential free. Only switch the
contacts individually (observe priority of the contacts). Otherwise
the desired speed is not activated.
NOTICE
The motor speed is switched on using the manual button or external
switch contacts. The switch
contacts and the assigned speed are
activated.
If the pump starts from a standstill, it starts up in priming mode and
subsequently with the selected fixed speed.
During operation the pump is started up to the fixed speed directly,
without priming time.
If external control is not necessary, the cable ends need to be insulated.
NOTICE
For easy interaction with peripheral devices such as electric heat
exchangers or dosing systems,
installing a flow monitor with the
appropriate evaluation unit is recommended
. This can also output a fault
message.
EN 16 03|2022
NOTICE
The following points must be observed in order to avoid motor
malfunctions:
The control line should be correctly installed by a specialist.
Assembly parallel to power lines or their load should be avoided.
Should the control lines be extended, dangerous voltages can occur
at the digital input. These should be avoided with isolation.
The power cables for various inputs should not be connected to the
same supply line.
Default setting:
Speed:
Priming speed:
Priming time:
Speed which can be set:
Priming time which can be set:
External controlling:
Switching behaviour Input "0":
1 = 2000 min-1
2 = 2400 min-1
3 = 2850 min-1
= 2850 min-1
= 5 minutes
1000 3000 min-1 (in 10 min-1 steps)
oFF, 1 10 min. (in 1 min. steps)
oFF
0 cl
Pos: 23.1 /T ech nisc he D okum en tat ion Spec k P umpe n/Pum penda tenbl att/M otors teuer ung/Ec o/Ec o VS/B edien oberfl äche @ 9\mod_1495014516488_370.docx @ 116177 @ @ 1
User interface:
(1) LED display: displays the current speed
of the motor.
(2) : selection of the preset speeds
(3) : to display the current consumption
and select the parameters in the setup.
(4) : to set the parameters.
(5) ": to change the speed
.
(6) : to stop the motor.
The software version "-rX.X-" is displayed briefly when the supply
voltage is switched on.
Priority
Low
n1
High
Stop
WG27.50.094-2-P
n2 n3
WG27.50.006-P
4
6
5
1
2
3
03|2022 EN 17
Operation:
Press the button , or to select the preset
fixed speed.
If the pump starts from a standstill, it starts up in
priming mode (in far as it is activated) and
subsequently with the selected fixed speed.
As long as the pump is in the priming phase a bar
moves in the first position on the display from the
lower, through the middle to the upper position.
During operation the pump is started up to the fixed
speed directly, without priming time.
The motor is stopped by pressing the button. The
"Power" LED flashes and the display shows "oFF".
Setting the speeds:
Press the button of the fixed speed that is to be
changed ( , or ) and then change the speed
by using the buttons. The set speed is stored
directly and approached immediately when the fixed
speed is selected again.
Notice: The speed cannot be changed during the priming phase.
Setting the parameters:
You can change to the setup menu by pressing the
button for 3 seconds. There the button can be used
to scroll through the menu.
The first position of the display shows the current
menu item and the remaining four positions show the
parameter to be set.
If the button is pressed within the menu, all the
changed values are stored and the setup menu exited.
The text "StorE" is shown in the display.
If you press the button, the setup menu is exited
without the changed values being stored.
Priming parameters:
The speed is set under the menu item "n" while the
time during the priming phase is set under the item "t".
"t oFF" = no priming phase
from oFF, 1 - 10 minutes can be set
WG27.50.007-P
WG27.50.008-P
WG27.50.009-P
WG27.50.010-P
EN 18 03|2022
Digital Inputs:
External controlling can be activated or deactivated
with the menu item "E".
"oFF" = deactivated
"dl" = digital inputs (potential-free) activated
Switching behaviour "0" (stop):
The switching behaviour of the digital input "0" can be
changed (inverted) by using the menu item "0".
"cL" means that the motor is stopped at a closed
contact.
"oP" means that the motor is stopped at an open
contact.
Resetting:
The motor is reset to the factory setting when the
button is pressed for at least 10 seconds. The motor
stops and "rESEt" is displayed.
The pump’s current power requirements are shown in
watt (P XXX) in the display when the button is
pressed.
The control unit's display switches off after three
minutes without action.
After a voltage drop the pump automatically starts up again with the
speed last set, or remains stopped if it had been stopped beforehand.
The pump can be turned on and off using the control cable (potential-free
contact) intended for this purpose. This can be via a BADU Logic control,
BADU OmniTronic or via a small coupling relay. This puts less stress on
the electronics.
Overview of possible operating and error messages
If an error occurs, the motor switches off permanently and a message is
displayed. Exception: "Under voltage" if there is a failure or the power
supply switches off. In this case the motor restarts when the power supply
is switched on again.
If a defect occurs, the system must be disconnected from the power
supply. See chapter 2.2 of the original operating manual "Non self-priming
and self-priming pumps with/without plastic lanterns (AK version)".
WG27.50.011-P
WG27.50.012-P
WG27.50.013-P
WG27.50.014-P
03|2022 EN 19
Error No.
Description
Err 1
Undervoltage intermediate circuit
Err 2
Overvoltage intermediate circuit
Err 3
Supply voltage too low/too high
Err 4
Temperature at the power electronics too high
Err 5
Overtemperature motor
Err 7
Overcurrent electronics
Err 10
Current measurement faulty
Err 20
Abortion during start-up, overload
Err 64
Short-circuit electronics
Err 97
Simultaneous occurrence of several errors or faults
Err 98
Connection to the control unit faulty
Pos: 28 /T ech nisc he Do kum enta tio n Spec k P ump en/ Pumpe nda ten blat t/D eckel /Saug sieb dem onti eren bzw . monti ere n @ 3\mod_1437025205014_370.docx @ 36347 @ @ 1
Installing or removing the cover/strainer basket
W72.40.007-1-P
1
2
3
EN 20 03|2022
Changing the battery in the transparent inlay
1. Switch pump off.
2. Close shut-off vlaves.
3. Remove lid.
4. Unscrew the small lid (1) with the two pins (2) of the opening device.
5. Remove the inlay.
6. Push the LED out of the bottom of the inlay.
7. Exchange the batteries. 2x Type CR2032, 3V
Observe the pole (+/-)!
8. Assembly in reverse order.
W90.04.100-P
(1)
(2)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320

BADU Profi-MK Eco VS Istruzioni per l'uso

Tipo
Istruzioni per l'uso
Questo manuale è adatto anche per