Elkron IT3000-PSTN Guida d'installazione

Tipo
Guida d'installazione
1
IT3000-PSTN
DS80CT03-001 LBT81110
ELKRON
Tel. +39.011.3986711
Fax +39.011.3986703
www.elkron.com – [email protected]
ELKRON is a trademark of
URMET S.p.A.
Via Bologna, 188/C 10154 Torino (TO) – Italy
www.urmet.com
Made in Italy
I- Interfaccia linea telefonica
GB - Telephone line interface
F- Interface de ligne téléphonique
D- Telefonleitungsschnittstelle
-
Manuale completo
Complete manual
Manuel complet
Ungekürztes Handbuch
  
LEGENDA 
A L1 L2 

B PE 

C T1 T2 Linea

D PU


E L


F R


G O




H I








 


 
 
CARATTERISTICHE TECNICHE TECHNICAL FEATURESCARACTERISTIQUES TECHNIQUESTECHNISCHE EIGENSCHAFTEN 

 13,8 V

 10 ÷ 14,5 V


 15 mA





17 mA (13,8 V)

 40 x 70 mm

 







PWR
EXC TAMPER
RES
SW2 OPT1 OPT2
BUS
BUS
OPT3
+BAT-
+PS -PS
+ A B -
+ A B - +SR +V1 -V1 NC1 NO1 C1 U2 SAB +V2 -V2 IN1 IN2 IN3 IN4 IN5 IN6 +V2 -V2 P7 P8
OPER
COM
3+V3
CLOUD
RUN
RELÈ
OPT1

DESCRIZIONE GENERALE



MONTAGGIO
ATTENZIONE!non alimentata (rete e batteria sconnesse).


COLLEGAMENTO PE

COLLEGAMENTO LINEA TELEFONICA

nica entrante ai morsetti L1 e L2T1 e T2
CONFORMITA EN50136-2


1
IT3000-PSTN
IT3000-PSTN
LEGENDA SIMBOLI SYMBOL KEY  SYMBOLLEGENDE
Tensione di




continue

orgungsspannung



Zentrale MP3000.
ALLGEMEINE BESCHREIBUNG




MONTAGE
ACHTUNG


ERDANSCHLUSS (PE)

TELEFONLEITUNGSANSCHLUSS



KONFORMITÄT MIT EN 50136-2




DESCRIPTION




MONTAGE
ATTENTIONn’est pas alimentée (alimentation secteur et batteries débranchées).


BRANCHEMENT PE

BRANCHEMENT

L1 et L2T1 et T2

 EN50136-2




GENERAL DESCRIPTION



ASSEMBLY
IMPORTANTnot powered (mains and battery disconnected).


PE CONNECTION

TELEPHONE LINE CONNECTION

L1 and L2T1 and T2
EN50136-2 COMPLIANCE


1
1
1
This document contains only essential information about the product. Refer to the manuals of the MP3000 panel for more information.
GENERAL DESCRIPTION
IT3000-PSTN is an interface for connecting the MP3000 control panel to PSTN analogue communication networks. The interface can play pre-recorded voice
messages and receive and send DTMF tones for digital communication. It can establish communication with a remote alarm receiving station (management unit) by
DTMF tone coding (SIA Contact ID DC05 protocol) on a phonic channel. The interface is housed directly on the CPU board of the control panel.
ASSEMBLY
IMPORTANT Insert the interface only when the control panel is not powered (mains and battery disconnected).
Insert the 4 nylon spacers supplied into the holes provided on the interface.
Place the board in the OPT1 position of the CPU (see Fig. 1) Carefully aligning both connectors and the 4 spacers, applying adequate pressure until they engage.
OPT2/OPT3 positions can be used as an alternative.
PE CONNECTION
Connect the earth conductor (yellow-green cable) to the PE terminal of the interface. The connection must also be made in the case of a control panel in an ABS box.
TELEPHONE LINE CONNECTION
The MP3000 control panel must be the first device on the incoming line to be able to exclude all the others in the event of an alarm being generated. Connect the
incoming telephone line to terminals L1 and L2 (the polarity is irrelevant). Connect the downstream telephone sets to terminals T1 and T2 (the polarity is irrelevant).
EN50136-2 COMPLIANCE
The line control must be enabled with a time not exceeding 25h to ensure compliance with EN50136-2 in the configuration of the interface. DP1 is guaranteed with:
Primary IT3000-PSTN interface and LAN connector or alternative IT3000-2G interface, with periodic test not exceeding 25h enabled.
Le présent document contient quelques indications essentielles sur le produit. Pour plus de renseignements, se reporter aux manuels de la centrale MP3000.
DESCRIPTION GÉNÉRALE
IT3000-PSTN est une interface permettant de connecter la centrale MP3000 aux réseaux de communication analogique PSTN. L’interface peut reproduire des
messages vocaux préprogrammés et recevoir ou envoyer des tonalités DTMF pour les communications numériques. Elle peut établir la communication avec un
poste distant de réception des alarmes (centre de gestion) par codage DTMF à tonalités (protocole SIA Contact ID DC05) sur canal phonique. L’interface est
directement logée sur la carte CPU de la centrale.
MONTAGE
ATTENTION ! La pose de l’interface doit se faire uniquement lorsque la centrale n’est pas alimentée (alimentation secteur et batteries débranchées).
Insérer les quatre entretoises en nylon (livrées) dans les orifices prévus à cet effet sur l’interface.
Positionner la carte dans l’emplacement OPT1 de la CPU (voir Fig. 1), en veillant à aligner les deux connecteurs et les quatre entretoises en exerçant une pression
suffisante pour les encastrer. Il est néanmoins possible d’utiliser en alternative les emplacements OPT2/OPT3.
BRANCHEMENT PE
Brancher le conducteur de terre (câble jaune-vert) sur la borne PE de l’interface. Ce branchement doit être réalisé aussi en cas de centrale dans box ABS.
BRANCHEMENT DE LA LIGNE TÉLÉPHONIQUE
La centrale MP3000 doit être le premier appareil sur la ligne entrante, afin de pouvoir exclure tous les autres en cas d’émission d’une alarme. Brancher la ligne
téléphonique entrante sur les bornes L1 et L2 (la polarité est indifférente). Brancher les appareils téléphoniques en aval des bornes T1 et T2 (la polarité est indif-
férente).
CONFORMITÉ EN50136-2
Pour garantir la conformité à la norme EN50136-2, dans la configuration de l’interface, il est nécessaire d’habiliter le contrôle de la ligne avec une durée ne dépassant pas
25 heures. DP1 garanti avec : interface IT3000-PSTN primaire et connexion LAN ou interface IT3000-2G alternative, avec test périodique non supérieur à 25 heures
habilité.
In diesem Dokument sind nur einige wesentliche Angaben zum Produkt enthalten. Wegen weiterer Informationen beziehen Sie sich bitte auf die Handbücher der
Zentrale MP3000.
ALLGEMEINE BESCHREIBUNG
Die IT3000-PSTN ist eine Schnittstelle, die den Anschluss der Zentrale MP3000 an Netzwerke der analogen Festnetzkommunikation gestattet. Die Schnittstelle kann
vor- kompilierte Sprachnachrichten wiedergeben und DTMF-Tonsignale für digitale Kommunikationen empfangen und versenden. Sie kann eine Kommunikation zu
einer standortfernen Alarmempfangsstelle (Verwaltungszentrum) mittels DTMF-Codierung mit Tonsignalen (Protokoll SIA Contact ID DC05) auf Gesprächskanal
herstellen. Die Schnittstelle wird direkt auf der CPU-Karte der Zentrale untergebracht.
MONTAGE
ACHTUNG! Die Schnittstelle nur bei nicht mit Strom versorgter (Netzstrom und Batterie nicht angeschlossen) Zentrale einsetzen. Die 4 Abstandshalter aus Nylon aus
dem Lieferumfang in die dafür vorgesehenen Bohrungen der Schnittstelle einsetzen.
Die Karte in der Position OPT1 der CPU unterbringen (siehe Abb. 1) und dabei vorsichtig beide Verbinder und die 4 Abstandshalter ausrichten und angemessen
Druck ausüben, bis die Steckverbindung hergestellt ist. Es ist in jedem Fall glich alternativ dazu die Positionen OPT2/OPT3 zu verwenden.
ERDANSCHLUSS (PE)
Den Erdleiter (gelb-grüner Draht) an die PE-Klemme der Schnittstelle anschließen. Der Anschluss muss auch im Fall von Zentralen in ABS-Gehäuse erfolgen.
TELEFONLEITUNGSANSCHLUSS
Die Zentrale MP3000 muss das erste Geräte auf der eingehenden Leitung sein, um alle anderen im Fall der Alarmauslösung ausschließen zu können. Die eingehende
Telefonleitung an die Klemmen L1 und L2 anschließen (die Polarität ist unerheblich). Die Telefonapparate den Klemmen T1 und T2 nachgeschaltet anschließen (die
Polarität ist unerheblich).
KONFORMITÄT MIT EN 50136-2
Um bei der Konfiguration der Schnittstelle die Konformität mit EN 50136-2 zu garantieren, muss die Kontrolle der Leitung mit einem Zeitraum von nicht mehr als 25
Stunden aktiviert werden. DP1 garantiert mit: Hauptschnittstelle IT3000-PSTN und LAN-Verbindung oder alternativ Schnittstelle IT3000-2G mit regelmäßigem Test
von nicht über 25 Stunden Aktivierung.
ﻲ ﺑ ر ﻋ
يوﺗﺣﺗ اذھ ﺔﻘﯾﺛوﻟا ﻰﻠﻋ ضﻌﺑ تﺎﻣوﻠﻌﻣﻟا ﯾﺳﺎﺳﻷا طﻘﻓ ن ﻋ ﺞﺗﻧﻣﻟا. دﯾزﻣﻟ ن ،تﺎﻣوﻠﻌﻣﻟا ﻊﺟار
ّﻟدأ مدﺧﺗﺳﻣﻟا ﺎ ﺧ ا ةدﺣوﺑ مﻛﺣﺗﻟا ﺔﯾزﻛرﻣﻟاP3000M. تﻔﺻاوﻣ ﺔﻣﺎﻋ
PSTN-3000ITﻲھ ﺔﮭﺟاو ﯾﺗﺗ ك لﯾﺻوﺗ ةدﺣو ﯾزﻛرﻣﻟا مﻛﺣﺗﻟاP3000M تﺎﻛﺑﺷﺑ ل ﺎ ﺻ ﺗ ﻻ ا ﯾرظﺎﻧﺗﻟا .PSTN ن ﻣ ﯾ ﺔﮭﺟاوﻠﻟ رادﺻإ لﺋﺎﺳر ﺔﯾﺗوﺻ ة د ﻌ ﻣ
ًﻘﺑﺳﻣ لﺎﺑﻘﺗﺳاو لﺎﺳرإو ت ﺎ ﻐ ﻧ DTMF ﺔﺻﺎﺧﻟا تﻻﺎﺻﺗﻻﺎﺑ
ﺔﯾﻣﻗرﻟا
.
DTMF ) لوﻛوﺗورﺑ DC05 ID Contact SIA ( ﻰ ﻠ ة ﺎ ﻧ ﻘ ا ﺔﯾﺗوﺻﻟا. تﺑﺛﺗ ﺔﮭﺟاوﻟا ةرﺷﺎﺑﻣ ﻰﻠﻋ ﺔ ﺣ و ة د و ﺔﺟﻟﺎﻌﻣﻟا ﺔﯾزﻛرﻣﻟا ﮫﻧﻛﻣﯾ ءﺎﺷﻧإ ل ﺎ ﺻ ا ﻊﻣ ﺔ ط ﺣ ﻣ لﺎﺑﻘﺗﺳا راذﻧﻹا نﻋ دﻌُ
)زﻛرﻣ ةرادﻹا( ر ﺑ زﯾﻣرﺗ ﺔﻣﻐﻧ
CPU ﺻ ﺎ ﺧ ﻟ ا ةدﺣوﺑ مﻛﺣﺗﻟا ﯾزﻛرﻣﻟا.
بﯾﻛرﺗﻟا هﺎﺑﺗﻧا ! ل ﺧ د أ ﺔﮭﺟاوﻟا ﻲﻓ ة د ﺣ و مﻛﺣﺗﻟا ﺔﯾزﻛرﻣﻟا ط ﻘ ھ و ﺔﻟوﺻﻔﻣ ن رﺎﯾﺗﻟا )ﺔﻛﺑﺷﻟا ﺔﯾرﺎطﺑﻟاو نﻻوﺻﻔﻣ.(
ﻊﺿ ﺔﺣوﻠﻟا ﻲﻓ ﻊﺿو OPT1 ة د ﺣ و ﺔﺟﻟﺎﻌﻣﻟا ﺔﯾزﻛرﻣﻟا )رظﻧا ل ﻛ ﺷ ا (1، مﻗو ةاذﺎﺣﻣﺑ ل ﻛ ن ﻣ تﻼﺻوﻣﻟا ،ﺔﯾﺎﻧﻌﺑ ﻊﻣ ﺔﺳرﺎﻣ ط ﻐ ﺿ ا ﻲﻓﺎﻛﻟا ﻰﺗﺣ ر ﺳ ﺗ ﺎﮭﻧﺎﻛﻣ. ﺎﻣ نﻛﻣﯾ ك ذ ﻛ مادﺧﺗﺳا عﺎﺿوأ / OPT2
OPT3لﯾدﺑﻛ.
لﯾﺻوﺗ PE
مﻗ لﺻوﻣﻟا لﯾﺻوﺗﺑ ﻲ ﺿ ر ﻷ ا ) ل ﺑ ﺎ رﻔﺻأ-رﺿﺧأ( و PE ص ﺎ ﺧ ا ﺔﮭﺟاوﻟﺎﺑ. ب ﺟ ﯾ أ
ل ﺎ ﺻ ﺗ ا طﺧ فﺗﺎﮭﻟا
بﺟﯾ ن أ ن و ة د و مﻛﺣﺗﻟا ﺔﯾزﻛرﻣﻟا MP3000 ﻲھ زﺎﮭﺟﻟا لوﻷا ﻰﻠ طﺧﻟا ،دراوﻟا نﻣ ل ﺟ أ دﺎﻌﺑﺗﺳا ﻊﯾﻣ ة ز ﮭ ا ىرﺧﻷا ثودﺣ ر ا ذ ﻧ إ. مﻗ لﯾﺻوﺗﺑ طﺧ ف ﺗ ﺎ ا دراوﻟا فارطﺄﺑ L1
و L2 )ﺔﯾﺑطﻗ ةدﯾﺎﺣﻣ.( م ﻗ
ةزﮭﺟأ لﯾﺻوﺗﺑ ف ﺎ ﮭ ﻟ ا ﺔﯾﻘﻠﺗﻣﻟا تﺎﻣوﻠﻌﻣﻠﻟ تﻼﺻوﻟﺎﺑ T1 و L2 ) ﺔﯾﺑطﻗ ةدﯾﺎﺣﻣ.( ﺔﻘﺑﺎطﻣ EN50136-2
ﺔﻘﺑﺎطﻣﻟا نﺎﻣﺿﻟ ﻊﻣ EN50136-2 ﻲﻓ ﺋﯾﮭﺗ ،ﺔﮭﺟاوﻟا ن يرورﺿﻟا نﯾﻛﻣﺗ مﻛﺣﺗﻟا ﻲ ﻓ ط ﻟ ا تﻗوﺑ زوﺎﺟﺗﯾ25 ﺎ ﺳ. م ﺗ ﯾ نﺎﻣﺿ DP1 : ﺔ ﮭ ﺟ ا و IT3000-PSTN ﯾﺳﺎﺳﻷا لﯾﺻوﺗوLAN و أ ﺔﮭﺟاو IT3000-2G ،ﺔﻠﯾدﺑﻟا
ﻊﻣ نﯾﻛﻣﺗ رﺎﺑﺗﺧا يرود زوﺎﺟﺗﯾ 25 ﺔﻋﺎﺳ.
1
  • Page 1 1
  • Page 2 2

Elkron IT3000-PSTN Guida d'installazione

Tipo
Guida d'installazione