Beghelli LG230 Infinita LED X5 Manuale utente

Tipo
Manuale utente
A
infinita LED X5 LG230
334.902.078 E
IP65IK08
B
E
D
www.beghelli.com
BEGHELLI S.p.A. - Via Mozzeghine 13/15 - località Monteveglio 40053 Valsamoggia (BO) ITALY - Tel. +39 051 9660411 - Fax +39 051 9660444 - N° Verde 800 626626
C
+ cod. 4687
+ cod. 4683
foro incasso - recessed hole
326x132x40mm
503
+ cod. 4685
+ cod. 4315 (250mm)
+ cod. 4316 (500mm)
+ cod. 4317 (1000mm)
+ cod. 3723
Sostituzione lente - Lens replacement
325mm
198mm
83,5mm
60mm
45mm
130mm
1
4
5
6
7
2
3
*
A B C D
*
230Vac - 50/60Hz
216Vdc
ta -20÷40°C
B
BIP65
IP20 B Ø16-20mm
A*
A*
A
A*
F1 F2
Lente lungaluce 3m (A)
Lente lungaluce 7m (C) Lente largaluce 7m (D)
Lente largaluce 3m (di serie)
Lente altorischio (B)
ADDRESS
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
1-16
17-32
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
8
9
1
0
Luminairesaddress
1
F
OF
2
2
1
ON
8/N
7/L
*
230Vac - 50Hz 216Vdc
VA W
31172 12.4 11.4
APPARECCHI PER SEGNALETICA
E ILLUMINAZIONE DI EMERGENZA
L’apparecchio consente di centralizzare l'accensione e lo
spegnimento integrando funzioni di diagnosi. L’apparecchio
è dotato di un selettore rotativo per l’indirizzamento (Fig. F1).
In alternativa l’acquisizione in centrale può essere effet-
tuata automaticamente tramite il riconoscimento dell’ID
(Fig. F2).
(Fig. G) SCHEMI DI COLLEGAMENTO
- Collegamenti rete (L/+ ; N/-) rispettare le polarità.
- Collegamenti controllo LSSA: L; N (tensione 198 V a 254
V~) (Fig. G1-G2).
Il flusso luminoso in modalità emergenza è pari a quello
emesso in modo ordinario salvo diverso comportamento
dell’alimentatore.
FUNZIONE COMANDO LOCALE LSSA:
(Fig. G1) Funzione di comando tramite interruttore, posi-
zionare il DIP Switch “LSSA” su “ON” e il DIP Switch “UV”
su “LS-T”: l'apparecchio si accende se c’è tensione sul-
l'ingresso locale.
(Fig. G2) Monitoraggio di mancanza rete locale, posiziona-
re il DIP Switch “LSSA su “ON” e il DIP Switch “UV” su “LS-
F”: l'apparecchio si accende in EMERGENZA se NON c’è
tensione sull'ingresso locale.
(Fig. G2) Funzione di comando tramite interruttore, posi-
zionare il DIP Switch “LSSA” su “ON” e il DIP Switch “UV”
su “LS-F” - l’apparecchio si accende in modalità ordinaria,
se non c’è tensione sull'ingresso locale. Per attivare questa
funzione consultare il manuale duso in dotazione con la
Centrale.
L'apparecchio deve essere comunque programmato in
modo NON PERMANENTE sulla Centrale.
FUNZIONE SENZA COMANDO LOCALE LSSA:
(Fig. G3) Posizionare il DIP Switch su OFF; lo stato dell'ap-
parecchio è determinato dalla programmazione effettuata
sulla Centrale (Permanente, Non Permanente, Attivazione
temporizzata, attivazione su comando centralizzato).
PROGRAMMAZIONE SOGLIE DI DIAGNOSI
DIP switch settato di fabbrica.
Se la lampada è guasta, la corrente assorbita dal reattore
elettronico deve essere inferiore a WFAIL”.
CODIFICA
Indirizzi: da 1 a 16: (Fig. F1).
Indirizzi: da 17 a 32: (Fig. F1).
AVVERTENZE - GARANZIA
- Questo apparecchio dovrà essere destinato solo all'uso per
il quale è stato costruito. Ogni altro uso è da considerar-
si improprio e pericoloso.
- Per eventuali riparazioni rivolgersi ad un centro di assi-
stenza tecnica autorizzato e richiedere l'utilizzo di ricam-
bi originali. Il mancato rispetto di quanto sopra può com-
promettere la sicurezza dell'apparecchio.
- Per le modalità di intervento in garanzia contattare il
Numero Verde 800 626626 o il Rivenditore Autorizzato.
- Gruppo Rischio 0 a 300 cm
* Attenzione: scossa elettrica
NOUZOVÁ SVÍTIDLA PRO NOUZOVÉ ZNAČENÍ A
ÚNIKOVÉ CESTY
Svítidlo umožňuje centrální spínání i diagnostické funkce.
Svítidlo je vybaveno spínačem pro manuální adresování
(Obr. F1).
Případněmůže být adresování provedeno automaticky
přes centrální jednotku a to načtením ID (Obr. F2).
(Obr. G) SCHÉMA ZAPOJENÍ
- S ohledem na síťové připojení (L/+; N/-) a polaritu.
-PřipojeLSSA vstupu: L; N (napě198 V až 254 V ~) (Obr.
G1-G2). Světelný tok při normálním a nouzovém provo-
zu je stejný, s výjimkou odchylky ovládacího zařízení.
PROVOZ S MÍSTNÍM LSSA PŘÍKAZEM:
(Obr. G1) Pro funkci místního světelného spínače přepně-
te přepínačDIP z "LSSA" na "ON" a přepínačDIP z "UV"
na "LS-T" zařízení se zapne v normálním režimu se
současným napětím na místním vstupu.
(Obr. G2) Pro funkci monitorování místní sub-distribuce pře-
pněte přepínačDIP z "LSSA" na "ON" a přepínačDIP z
"UV" na "LS-F"zařízese zapne v nouzovém režimu bez
napětí na místním vstupu.
(Obr. G2) Pro funkci místního invertorového světelného spí-
nače přepněte přepínačDIP z "LSSA" na "ON" a přepínač
DIP z "UV" na "LS-F" – zařízení se zapne v normálním reži-
mu bez napětí, ž v případěpřepěnebo podpěna
místním vstupu. Chcete-li aktivovat tuto funkci, přečtěte si
návod k obsluze centrální jednotky.
Zařízení musí být naprogramováno do režimu Nouzového
svícení prostřednictvím centrální jednotky.
PROVOZ BEZ MÍSTNÍHO LSSA PŘÍKAZU:
(Obr. G3) Přepněte přepínačDIP do polohy "OFF". Zařízení
se přepne programováním na centrální jednotce.
KALIBRACE PŘIPOJENÉHO PŘÍKONU
Tovární přepínačDIP.
Pokud je svítidlo vadné, spotřeba proudu předřadníku musí
být menší než "W FAIL".
KÓDOVÁNÍ
Adresy: od 1 do 16 – (Obr. F1).
Adresy: od 17 do 32 – (Obr. F1).
UPOZORNĚNÍ - ZÁRUKA
- Toto zařízení může být použito pouze k účelu, pro ně
bylo vyrobeno. Jakékoliv jiné použibude považováno za
nevhodné a tím také nebezpečné.
- Pro případné opravy se obraťte na autorizované servisní
středisko, které používá pouze originální náhradní díly.
Nerespektování výše uvedených podmínek může ohrozit
bezpečnost svítidla.
- Riziková skupina 0 až 300 cm
* Upozornění: úrazu elektrickým proudem
EMERGENCY LUMINAIRE FOR EXIT SIGNS
AND ESCAPE ROUTES
The luminaire allows a centralised switching as well as dia-
gnostic functions.
The luminaire is equipped with a rotary switch for manual
addressing (Fig. F1). Alternatively the addressing can be
done automatically over the central by read-in of the ID
(Fig. F2).
(Fig. G) WIRING DIAGRAM:
- Consider mains connections (L/+; N/-) and polarity.
- Connections of the LSSA input: L; N (voltage 198 V to
254 V~) (Fig. G1-G2).
The light flux in normal operation and emergency operation
is the same, except of deviating performance of the control
gear.
OPERATION WITH LOCAL LSSA COMMAND:
(Fig. G1) For a function as local light switch, put DIP switch
“LSSA” to “ON” and DIP switch “UV” to “LS-T” – the devi-
ce will be switched on in normal operation with present
voltage on the local input.
(Fig. G2) For a function as local sub-distribution monito-
ring, put DIP switch "LSSA" to "ON" and DIP switch "UV" to
"LS-F" - the device will be switched on in emergency ope-
ration with absent voltage on the local input.
(Fig. G2) For a function as local inverted light switch, put DIP
switch "LSSA" to "ON" and DIP switch "UV" to "LS-F" - the
device will be switched on in normal mode with absent vol-
tage on the local input. To activate this function consult the
operating manual of the central.
The device must be programmed to non-maintained mode
over the central.
OPERATION WITHOUT LOCAL LSSA COMMAND:
(Fig. G3) Put DIP switch in position "OFF". The device will be
switched by the programming on the central.
CALIBRATION OF THE CONNECTION LOAD:
Factory-set DIP switch.
If the illuminant is defective the current consumption of the
control gear must be smaller than “WFAIL”.
CODING
Addresses: from 1 to 16: (Fig. F1).
Addresses: from 17 to 32: (Fig. F1).
WARNINGS - GUARANTEE
- This device shall be used exclusively for the purpose for
which it has been designed. Any other use is considered
improper and therefore dangerous.
- Contact an authorised technical service centre for repairs
possibly required use only original spare parts. The lacked
respect of the above conditions may compromise the
safety of the device.
- For details regarding warranty services, contact an autho-
rized dealer.
- Risk Group 0 to 300 cm
* Caution: electric shock
NOTLEUCHTE FÜR RETTUNGSZEICHEN
UND FLUCHTWEGE
Die Leuchte ermöglicht ein zentralisiertes Schalten sowie
Diagnosefunktionen.
Die Leuchte ist mit einem Drehschalter zur manuellen
Adressierung ausgestattet (Abb. F1).
Alternativ kann die Adressierung automatisch über die
Zentrale durch Einlesung der ID erfolgen (Abb. F2).
(Abb. G) ANSCHLUSSSCHEMA:
-Netzanschlüsse (L/+; N/-) und Polung berücksichtigen.
-Anschlüsse des LSSA-Eingangs: L; N (Spannung 198 V bis
254V~) (Abb. G1-G2).
Der Lichtstrom ist im Normalbetrieb und Notbetrieb gleich,
außer bei abweichendem Verhalten des Vorschaltgeräts.
BETRIEB MIT LOKALEM LSSA-BEFEHL:
(Abb. G1) Für eine Funktion als Lichtschalter, DIP-Schalter
LSSA auf ON stellen und DIP-Schalter UV auf LS-T
stellen das Gerät wird bei anliegender Spannung am loka-
len Eingang im Normalbetrieb eingeschaltet.
(Abb. G2) Für eine Funktion als lokale
Unterverteilungsüberwachung, DIP-Schalter "LSSA" auf
"ON" stellen und DIP-Schalter "UV" auf "LS-F" stellen -
das Gerät wird bei fehlender Spannung am lokalen Eingang
im Notbetrieb eingeschaltet.
(Abb. G2) Für eine Funktion als lokaler, invertierter
Lichtschalter, DIP-Schalter "LSSA" auf "ON" stellen und
DIP-Schalter "UV" auf "LS-F" stellen - das Gerät wird bei
fehlender Spannung am lokalen Eingang im Normalbetrieb
eingeschaltet. Um diese Funktion zu aktivieren, konsultie-
ren Sie die Bedienungsanleitung der Zentrale.
Das Gerät muss über die Zentrale auf Bereitschaftsschaltung
programmiert sein.
BETRIEB OHNE LOKALEN LSSA-BEFEHL:
(Abb. G3) DIP-Schalter auf Position "OFF" stellen. Das Gerät
wird durch die Programmierung an der Zentrale geschaltet.
KALIBRIERUNG DER ANGESCHLOSSENEN LAST:
DIP-Schalter im Werk voreingestellt.
Wenn das Leuchtmittel defekt ist, muss die Stromaufnahme
des Vorschaltgeräts kleiner als WFAIL sein.
KODIERUNG
Adressen: von 1 bis 16: (Abb. F1).
Adressen: von 17 bis 32: (Abb. F1).
WARNUNGEN - GARANTIE
- Das Gerät darf ausschließlich für den Zweck, für den es
hergestellt wurde, verwendet werden. Jede davon abwei-
chende Verwendung wird als nicht zweckentsprechend
und somit als gefährlich angesehen.
-Wenden Sie sich bei Reparaturen an eine autorisierte
Servicestelle oder fordern Sie Originalersatzteile an. Das
Nichteinhalten vorstehender Bestimmungen kann die
Gerätesicherheit gefährden.
-Für die Vorgehensweise bei Garantieleistungen wenden
Sie sich an den autorisierten Händler.
-Risikogruppe 0 bis 300 cm
* Achtung: es besteht die gefahr des elektrischen
schalages
N/-
L/+
N
L
N/- L/+ N L
AC
Local
Line
AC/DC
Line IN
C
AC
Local
G
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
G1
G2
G3
DIP switch settato di fabbrica
Factory-set DIP switch
DIP-Schalter im Werk voreingestellt
C*= comando SA ad interruzione di fase
C*= Switch Control with phase interruption
C*= Lichtschalter mit Phasenunterbrechung
230Vac ±10%
216Vdc ±20%
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
Local LSSA Mode
230 VAC
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
UV Mode
230 VAC
16
32
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
Normal Mode
V
SWITCH COD. WFAIL
31172 < 7W
  • Page 1 1
  • Page 2 2

Beghelli LG230 Infinita LED X5 Manuale utente

Tipo
Manuale utente