Danfoss MMIMYK Guida d'installazione

Tipo
Guida d'installazione
RS485
(Modbus)
CANBus
RS485
POWER SUPPLY 12 V DC
POWER SUPPLY 24 V AC
CAN-RJ
12 Vdc24 Vac
CANRS485
D+ D-RHLGND GND
+
-
SD/MMC
Card
Mini USB
SD/MMC CARD MINI USB
~
~
24 V
10 VA
If powered by 24 Vac then
it is mandatory to use
a dedicated transformer
!
Danfoss
80G8076.01
12 Vdc24 Vac
CANRS485
D+ D-RHL GND GND
+
-
105
72
31
Danfoss
80G8077.01
Memory card
Modbus RS485
485
Danfoss
80G8075.01
ww w.danfoss.com/mcx
DKRCC.PI.RJ0.B3.1U
3106000360
Via San Giuseppe 38/G
31015 Conegliano
(TV) Italy
Tel: +39 0438 336611
Fax: +39 0438 336699
info.mcx@danfoss.com
www.danfoss.com
AVVERTENZE
CARATTERISTICHE CONTENITORE
- Agganciabile su guida DIN secondo EN 60715
- Prova biglia: 125 °C secondo IEC 60730-1. Resistenza alle correnti superficiali: ≥ 250 V secondo IEC 60112
ALTRE CARATTERISTICHE
- Condizioni di funzionamento CE: -20T60, 90% UR non condensante
- Condizioni di immagazzinamento: -30T80, 90% UR non condensante
- Da integrare in apparecchiature di classe I e/o II
- Grado di protezione: IP20 sul solo frontale
- Periodo di sollecitazione elettriche delle parti isolanti: lungo
- Adatto per l’uso in ambiente con grado di polluzione normale
- Categoria di resistenza al calore e al fuoco: D
- Immunità contro le sovratensioni: categoria I
- Classe e struttura del software: A
CONFORMITÀ CE
Questo prodotto è progettato in modo da garantire la conformità con le seguenti direttive dell’Unione Europea:
- Direttiva bassa tensione: 73/23/EEC
- Compatibilità elettromagnetica EMC: 89/336/EEC e con le seguenti norme armonizzate:
- EN61000-6-1, EN61000-6-3 (immunità ed emissione per gli ambienti residenziali, commerciali e dell’industria
leggera)
- EN61000-6-2, EN61000-6-4 (immunità ed emissione per gli ambienti industriali)
- EN60730 (dispositivi elettrici automatici di comando per uso domestico e similare)
AVVERTENZE
- Ogni utilizzo diverso da quanto descritto nel presente manuale è da ritenersi improprio e non è pertanto
autorizzato
- Verificare che le condizioni limite di funzionamento a cui l’apparecchiatura è sottoposta rientrino tra quelle
specificate, in particolare per quanto riguarda la tensione di alimentazione e le condizioni ambientali
- L’apparecchiatura non può essere utilizzata come dispositivo di sicurezza
- La responsabilità di lesioni o danni causati da uso improprio ricadrà esclusivamente sull’utilizzatore
AVVERTENZE PER L’INSTALLAZIONE
- Linstallazione deve essere eseguita secondo le normative e legislazioni vigenti nel paese di utilizzo
dell’apparecchiatura
- Operare sui collegamenti elettrici sempre ad apparecchiatura non alimentata
- Prima di effettuare qualsiasi operazione di manutenzione sulla apparecchiatura, disinserire tutti i collegamenti
elettrici
- Non esporre l’apparecchiatura sotto continui getti d’acqua o ad un umidità maggiore del 90%. In generale
evitare l’esposizione ad atmosfere aggressive ed inquinanti, agli agenti atmosferici, ad ambienti ove sono
presenti esplosivi o miscele di gas infiammabili, alla polvere, a forti vibrazioni, a repentine variazioni di
temperatura che abbinate ad alta umidità possono provocare la formazione di condensa e a fonti di
interferenze elettromagnetiche (ad es. antenne trasmittenti)
- Utilizzare capicorda adatti per i morsetti in uso; dopo la chiusura delle viti dei morsetti, tirare leggermente i cavi
per verificarne la tenuta
- Usare cavo appropriato per le linee di comunicazione. Fare riferimento alla Guida di Installazione
“MCX hardware network specification per il tipo di cavo da usare e le raccomandazioni da osservare nei
collegamenti
- Ridurre il più possibile il percorso dei cavi dei sensori e degli ingressi digitali, allontanandoli dai cavi dei carichi
induttivi e di potenza per evitare possibili disturbi elettromagnetici
- Non avvicinare le dita ai componenti elettronici dell’apparecchiatura per evitare la generazione di scariche
elettrostatiche
MMIMYK
DATI TECNICI
Alimentazione
- da MCX attraverso connettore telefonico RJ11
- 12 V DC (da connettore DC)
- 24 V AC (da connettori estraibili passo 3,5 mm): per questa alimentazione si consiglia di usare un trasformatore 24 V AC / 10 VA dedicato. E’ obbligatorio se MMIMYK è collegato ad un
dispositivo senza isolamento tra l’alimentazione e la bassissima tensione come LCX06C e EXD316
- da USB 2.0 (massimo 500 mA)
Memoria
- interna 2 MB
- slot di espansione SD/MMC (Multi Media Card) fino a 2 GB
INTERFACCIA UTENTE
Display
- grafico OLED
- risoluzione 128x64 punti
- area visibile attiva 35x17,5 mm
Tastiera - 4 tasti
Montaggio - barra DIN o portatile
VARIE
CANbus - isolato rispetto a USB
Seriale Modbus RS485 - isolata rispetto a USB
Buzzer
Orologio RTC
SCHEMA DI RETE
COLLEGAMENTO DIRETTO A MCX COLLEGAMENTO IN RETE COLLEGAMENTO IN RETE
MMIMYK alimenta MCX
(funzione di programmazione)
MMIMYK alimentata da MCX MMIMYK alimentata
esternamente
SCHEMA DI COLLEGAMENTO DIMENSIONI
Display OLED
CONNESSIONI
- Connettore CAN-RJ
6/6 vie tipo telefonico RJ11 plug
- Connettore power supply
tipo DC JACK Ø 3,5 x 1,3 mm
- Connettore power supply 24 Vac
2 Vie tipo morsetto a vite estraibile passo 3,5 mm: sezione cavo 0,08-1,5 mm²
- Connettore CAN
4 Vie tipo morsetto a vite estraibile passo 3,5 mm: sezione cavo 0,08-1,5 mm²
- Connettore RS485
3 Vie tipo morsetto a vite estraibile passo 3,5 mm: sezione cavo 0,08-1,5 mm²
- Connettore USB: tipo mini B
- Connettore SD/MMC
per scheda di memoria tipo SD/MMC fino a 2 GB
CODICI IDENTIFICATIVI PRODOTTO
CODICE DESCRIZIONE
080G0073
MMIMYK, PC/MCX INTERFACE AND MCX PROGRAMMING, DATA LOGGING,
Single Pack
CARATTERISTICHE GENERALI
MMIMYK è l’innovativo dispositivo “all in one” che svolge fino a tre funzioni differenti: - Modulo di programmazione - Gateway - Data logger.
E’ dotato di un luminoso display grafico e di una tastiera che ne permettono un facile utilizzo. E’ dotata di uno slot per scheda SD/MMC (Multi Media Card) per espandere ulteriormente la capacità di memoria.
SMALTIMENTO DEL PRODOTTO
- L’apparecchiatura (o il prodotto) deve essere oggetto di raccolta separata in conformità alle vigenti
normative locali in materia di smaltimento.
La Danfoss non si assume alcuna responsabilità circa eventuali errori nei cataloghi, pubblicazioni o altri documenti scritti. La Danfoss si riserva il diritto di modificare i suoi prodotti senza previo avviso, anche per
i prodotti già in ordine sempre che tali modifiche si possano fare senza la necessità di cambiamenti nelle specifiche che sono già state concordate.
Tutti i marchi di fabbrica citati sono di proprietà delle rispettive società. Il nome Danfoss e il logo Danfoss sono marchi depositati della Danfoss A/S. Tutti i diritti riservati.
DKRCC.PI.RJ0.B3.1U / 520H9963 - MMIMYK foglio istruzioni - P.N. 3106000360 - 15-310600036-E
© Danfoss A/S (RAC-DCS-IMCGP / az), 2015.04
Foglio istruzioni
Controllo elettronico
MMIMYK
RS485
(Modbus)
CANBus
RS485
POWER SUPPLY 12 V DC
POWER SUPPLY 24 V AC
CAN-RJ
12 Vdc24 Vac
CANRS485
D+ D-RHLGND GND
+
-
SD/MMC
Card
Mini USB
SD/MMC CARD MINI USB
~
~
24 V
10 VA
If powered by 24 Vac then
it is mandatory to use
a dedicated transformer
!
Danfoss
80G8076.01
12 Vdc24 Vac
CANRS485
D+ D-RHL GND GND
+
-
105
72
31
Danfoss
80G8077.01
Memory card
Modbus RS485
485
Danfoss
80G8075.01
ww w.danfoss.com/mcx
DKRCC.PI.RJ0.B3.1U
3106000360
Via San Giuseppe 38/G
31015 Conegliano
(TV) Italy
Tel: +39 0438 336611
Fax: +39 0438 336699
info.mcx@danfoss.com
www.danfoss.com
CONNECTION DIAGRAM DIMENSIONS
OLED display
CONNECTIONS
- CAN-RJ connector
6/6 way telephone RJ11 plug type
- Power supply connector
DC JACK type Ø 3.5 x 1.3 mm
- Power supply 24 Vac connector
2 way screw plug-in connector type pitch 3.5 mm: section cable 0.08-1.5 mm²
- CAN connector
4 way screw plug-in connector type pitch 3.5 mm: section cable 0.08-1.5 mm²
- RS485 connector
3 way screw plug-in connector type pitch 3.5 mm: section cable 0.08-1.5 mm²
- USB connector: mini type B
- SD/MMC connector
for memory card SD/MMC type up to 2 GB
PRODUCT PART NUMBERS
CODE DESCRIPTION
080G0073
MMIMYK, PC/MCX INTERFACE AND MCX PROGRAMMING, DATA LOGGING,
Single Pack
GENERAL FEATURES AND WARNINGS
HOUSING FEATURES
- DIN rail mounting complying with EN 60715
- Ball test: 125 °C according to IEC 60730-1. Leakage current: ≥250 V according to IEC 60112
OTHER FEATURES
- Operating conditions CE: -20T60, 90% RH non-condensing
- Storage conditions: -30T80, 90% RH non-condensing
- To be integrated in Class I and/or II appliances
- Index of protection: IP20 only on the front cover
- Period of electric stress across insulating parts: long
- Suitable for using in a normal pollution environment
- Category of resistance to heat and fire: D
- Immunity against voltage surges: category I
- Software class and structure: class A
CE COMPLIANCE
This product is designed to comply with the following EU standards:
- Low voltage guideline: 73/23/EEC
- Electromagnetic compatibility EMC: 89/336/EEC and with the following norms:
- EN61000-6-1, EN61000-6-3 (immunity for residential, commercial and light-industrial environments)
- EN61000-6-2, EN61000-6-4 (immunity and emission standard for industrial environments)
- EN60730 (Automatic electrical controls for household and similar use)
GENERAL WARNINGS
- Every use that is not described in this manual is considered incorrect and is not authorised by the
manufacturer
- Verify that the installation and operating conditions of the device respect the ones specified in the
manual, specially concerning the supply voltage and environmental conditions
- The device can’t be used as a safety device
- Liability for injury or damage caused by the incorrect use of the device lies solely with the user
INSTALLATION WARNINGS
- The installation must be executed according the local standards and legislation of the country
- Always operate on the electrical connections with the device disconnected from the main power supply
- Before carrying out any maintenance operations on the device, disconnect all the electrical connections
- Don’t expose the device to continuous water sprays or to relative humidity greater than 90%.
Avoid exposure to corrosive or pollutant gases, natural elements, environments where explosives or
mixes of flammable gases are present, dust, strong vibrations or shock, large and rapid fluctuations in
ambient temperature that in combination with high humidity can condensate, strong magnetic and/or
radio interference (e.g. transmitting antennae)
- Use cable ends suitable for the corresponding connectors. After tightening the screws of connectors,
slightly tug the cables to check their tightness
- Use appropriate data communication cables. Refer to the Installation Guide “MCX hardware network specification”
for the kind of cable to be used and setup recommendations
- Reduce the path of the probe and digital inputs cables as much as possible, and avoid spiral paths
enclosing power devices. Separate from inductive loads and power cables to avoid possible
electromagnetic noises
- Avoid touching or nearly touching the electronic components fitted on the board to avoid electrostatic
discharges
MMIMYK
TECHNICAL SPECIFICATIONS
Power supply
- from the MCX through the RJ11 telephone connector
- 12 V DC (from DC connector)
- 24 V AC (from screw plug-in connector type pitch 3.5 mm): on this supply it is advisable to use a dedicated transformer 24 V AC / 10 VA.
It is mandatory if MMIMYK is connected to devices without insulation between power supply and extra-low voltage such as LCX06C and EXD316
- from USB 2.0 (maximum 500mA)
Memory
- internal 2 MB
- SD/MMC expansion slot (Multi Media Card) up to 2 GB
USER INTERFACE
Display
- graphic OLED
- display format 128x64 dots
- active visible area 35x17.5 mm
Keyboard - 4 keys
Mounting - DIN rail or portable
OTHERS
CANbus - isolated with respect to USB
Modbus RS485 serial interface - isolated with respect to USB
Buzzer
RTC clock
NETWORK DIAGRAM
DIRECT CONNECTION TO MCX NETWORK CONNECTION NETWORK CONNECTION
MYK supplies power to MCX
(programming function)
MYK powered by MCX MYK externally powered
GENERAL FEATURES
MMIMYK is the advanced “all in one device that performs up to three different functions: - Programming module - Gateway - Data logger.
It has a bright graphic display and a keyboard that enable to configure the module to run several functions. It has also a slot for SD/MMC card (Multi Media Card) to extend the memory capacity.
DISPOSAL INSTRUCTION
- Equipment containing electrical components may not be disposed together with domestic waste. It
must be separately collected with electrical and electronic waste according to local and valid legislation.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on
order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
DKRCC.PI.RJ0.B3.1U / 520H9963 - MMIMYK instruction sheet - P.N. 3106000360 - 15-310600036-E
Instruction sheet
Electronic controller
MMIMYK
© Danfoss A/S (RAC-DCS-IMCGP / az), 2015.04
  • Page 1 1
  • Page 2 2

Danfoss MMIMYK Guida d'installazione

Tipo
Guida d'installazione

in altre lingue