Zanussi ZH6022ALU Manuale utente

Categoria
Cappe da cucina
Tipo
Manuale utente
4324142 - 01/98
Operating instructions
Bedienungsanleitung
Mode d'emploi
Gebruiksaanwijzing
Istruzioni per l'uso
Cooker hood
Dunstabzugshaube
Hotte
Wasemkap
Cappa
ZH 6022
ZH 9022
Dir. 89/336/CEE
CONTENTS
DESCRIBING THE
COOKER HOOD
IDENTIFICATION OF
THE APPLIANCE
PRODUCT
SAFETY WARNINGS
DIMENSIONS
SETTING UP AND
INSTALLATION
ELECTRICAL
CONNECTION
CONTROLS
SWITCHING THE
APPLIANCE
ON AND OFF
MAINTENANCE AND
CLEANING
1
5
7
9
23
25
41
43
45
49
1
2
This cooker hood features
a through flow retractable
visor which allows the
hood to be installed inside
a wall cabinet with the
minimum loss of space
while offering a large
collection area for
contaminated air once
extended into its working
position.
DESCRIBING THE
COOKER HOOD
The controls are located in
a concealed control box
which can be opened
during use; the opening of
the visor can be used to
switch the appliance on
when the controls have
been pre-set.
The cooker hood can be
installed in two different
ways:
RECIRCULATION MODE
using charcoal filters to
purify the contaminated air.
EVACUATION MODE
Using ducting to extract
the contaminated air to the
atmosphere.
The grease filters are fitted
to absorb grease and dust
during cooking.
The hood can be supplied
with metal or paper filters.
The paper filters have
saturation indicators and
should be located on the
internal side of the grille
with the spots facing
outwards.
Worktop illumination
consists of a fluorescent
strip light
or of two lamps.
3
4
5
6
IDENTIFICATION OF
THE APPLIANCE
The rating plate is situated
inside the casing. It gives
the model number and
serial number which should
be quoted in any
communication or if After
Sales Service is required.
7
8
PRODUCT
This cooker hood has been
designed for the
purification of
contaminated air and to
remove odours in the
kitchen.
ATTENTION:
This cooker hood must
not be used for the
purification of air which
could contain harmful
gases or poisons or
other substances not to
be found during normal
cooking.
9
10
SAFETY WARNINGS
ATTENTION:
Before carrying out any
kind of maintenance or
cleaning disconnect the
hood from the mains
supply and unplug the
cooker hood.
Connect the hood to the
mains supply via a double
pole switch which has
3mm minimum clearance
between the contacts.
1211
Before connecting this
appliance to the mains
supply, ensure that the
mains voltage corresponds
to the voltage on the rating
plate inside the hood.
This appliance must be
earthed.
ATTENTION:
Only use earthed plugs
or sockets.
ATTENTION:
Do not use any adapters
or extensions.
13 14
Never do flambè cooking
under this cooker hood.
When using a gas hob in
conjunction with this
cooker hood never leave
the burners of the hob
uncovered while the hood
is in use, or when the pans
have been removed.
Switch off the gas before
removing the pan, or for
just short periods and
never leave the hob
unattended.
When used in the
extraction mode the cooker
hood ducting must not be
connected to a flue which
is used for exhausting
fumes from appliances
supplied with energy other
than electric such as a
central heating flue or
water heating flue.
When installed, the hood
must be positioned at least
65cm above a cooking
appliance.
16
15
If the room where the
cooker hood is to be used
contains a fuel burning
appliance such as a central
heating boiler then this
must be of the room
sealed or balanced flue
type.
If other types of flue or
appliance are fitted ensure
that there is an adequate
supply of air to the room.
The cooker hood in fact
could extract the air which
is needed for burning.
When the cooker hood and
appliances supplied with
energy other than
electricity are
simultaneously in
operation the negative
pressure in the room must
not exceed 0,04 mbar in
order to avoid a return of
the gaz emissions.
This is possible through
openings in doors,
windows, or air inlet valves
allowing fresh air to enter
the kitchen.
In any case, in connection
with the discharge of
exhaust air, the
requirements of the
authorities concerned have
to be observed.
Never leave frying pans
unattended during use as
overheated fat and oil may
catch fire.
Always ensure that the
flame is kept at the correct
intensity to prevent the
flame from licking round
from the bottom of the pan;
this will save energy and
will avoid a dangerous
concentration of heat.
17
18
ATTENTION:
There could be a
possible fire hazard if
the grease filters are not
cleaned or replaced
when necessary and
according to these
instructions.
The grease filters and
charcoal filters should be
cleaned or replaced as
recommended by the
manufacturer or more
frequently if the hood is
used consistently for more
than 4 hours per day.
ATTENTION:
Please read the
instruction booklet
carefully before
installing or using this
appliance.
ATTENTION:
Do not insert
hands or any other
object into the air outlet.
20
19
Do not use wet clothes or
sponges to clean the
surfaces of the cooker
hood.
Should your cooker hood
fail to function at anytime
repairs should be carried
out by a qualified
electrician or a competent
person.
When carrying out any
kind of maintenance or in
the event that your cooker
hood stops functioning,
switch off the mains supply
and disconnect the plug
from the socket. This
appliance should be
serviced by an authorized
Service Centre, and only
genuine spare parts should
be used.
Not following this warning
could affect the safety of
your cooker hood.
2221
DIMENSIONS
2423
SETTING UP AND
INSTALLATION
2625
Before unpacking the
cooker hood position the
carton with arrows pointing
upwards as illustrated.
Remove the cooker hood
and polystyrene side
protection complete from
the carton.
Insert the ducting spigot
into the aperture on the top
of the cooker hood casing.
Position the cooker hood
upside-down, and ensuring
the hood is supported
correctly open the visor
and remove the two metal
grease filters or paper
grease filter grilles. To
remove the filters press
inwardly on the actuator
bolts at either side of the
grille and remove. Cooker
hoods in 60 cm are
provided with 2 metal
filters or grilles.
2827
The cooker hood in 90 cm
is provided with 4 grease
filters which should be
removed using the same
method as for the 60 cm
model.
Cut a round hole in the
upper side of the cabinet
aligning it with the air outlet
of the cooker hood.
MOD.
AB
55 453 162
60 503 162
90
803 162
90
503 162
*
*
Special execution:
cooker hood 90 cm with
casing in 60 cm.
Cut a rectangular hole into
the underside of the
cabinet in accordance with
the table below.
A
B
3029
Insert the upper casing of
the hood through the hole
from the underside of the
cabinet.
If you wish to replace the
factory fitted front strip with
a personnalized strip
remove the three screws.
Remove the front strip.
Drill the new front strip
taking care to align it
correctly.
3231
If necessary adjust the
lower assembly
horizontally by loosening
the four screws and
closing the visor.
Fix the new front strip with
the screws provided.
Fasten the screws of the
butterfly quick fixing
system.
3433
Move the lower assembly
as necessary to align the
front with the cabinet door.
Hold the hood body
steady, open the visor and
tighten the fixing screws.
Fix the controls support
to the underside of the
cabinet using a provided
screw.
Now it is possible to install
the cabinet to the wall.
36
35
The cooker hood can be
installed in two different
ways:
RECIRCULATION
FITTING:
using cleansing charcoal
filters to purify the
contaminated air from
cooking and to recirculate
it back into the kitchen.
DUCTING FITTING:
(without cleansing charcoal
filter) to pass contaminated
air out through ducting to
the atmosphere.
RECIRCULATION
FITTING:
If the cooker hood is to be
installed in the recirculation
mode then charcoal filters
must be provided.
Insert che charcoal filters
as illustrated ensuring that
they click into position
correctly.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Zanussi ZH6022ALU Manuale utente

Categoria
Cappe da cucina
Tipo
Manuale utente

in altre lingue