Contura Contura C890G Manuale utente

Categoria
Stufa a legna
Tipo
Manuale utente

Questo manuale è adatto anche per

890 Style
890G Style
contura.eu
SE
FR
FI
DE
GB
IT
NO
DK
NL
Fakta 3
Données Techniques 15
Tiedot 27
Fakten 7
Facts 19
Dati Tecnici 31
Fakta 11
Fakta 23
Gegevens 35
Installationsavstånd 4
Distances d’installation 16
Asennusetäisyys 28
Installationsabstände 8
Installation distances 20
Distanze di sicurrezza 32
Installasjonsavstand 12
Installationsafstand 24
Installatieafstand 36
Prestandadeklaration 5
Déclaration des performance 17
Suoritustasoilmoitus 29
Leistungsdeklaration 9
Declaration of performance 21
Dichiarazione di prestazione 33
Ytelseserklæring 13
Præstationserklæring 25
Prestatieverklaring 37
Montering 39
Montage 39
Asennus 39
Montage 39
Assembly 39
Montaggio 39
Montering 39
Montering 39
Monteren 39
GB
19
!
3-7 kW 1260 mm 465 mm 365 mm 90 kg
Installation by authorised
technician
This manual contains instructions about how
the stoves must be assembled and installed.
To ensure the function and safety of the stove,
we recommend that the installation is carried
out by an authorised technician. Contact one
of our dealers who can recommend suitable
technicians.
Building application
These main instructions may give guidance
which would contravene national building
regulations. Please refer to supplementary
instructions or ask your local authority for
advice regarding building regulations.
Before installing a stove or erecting a chimney
it is necessary for you to make a building
application permission to your local authority.
The owner of the house is personally
responsible for ensuring compliance with the
mandatory safety requirements and must
have the installation approved by a qualified
inspector. Your local chimney sweep must
also be informed about the installation as this
will affect the routines for regular chimney-
sweeping services.
Structural support
Check that the wood joists are strong enough
to bear the weight of the stove and chimney.
The stove and chimney can usually be placed
on a normal wooden joist in a single occupancy
house if the total weight does not exceed
400 kg.
Hearth plate
Due to the risk of falling embers, a flammable
floor must be protected by a hearth plate. It
must extend 300 mm in front of the stove and
100 mm on each side of the stove, or have a
200 mm extension on each side of the opening.
The hearth plate can consist of natural stone,
concrete, metal plate or glass. A glass hearth
plate is available as an accessory for these
models.
Final inspection of the
installation
It is extremely important that the installation
is inspected by an authorised chimney sweep
before the stove is used. Also read the
”Lighting instructions”, before lighting for the
first time.
Nominal effect 5 kW
Efficiency 81 %
Flue gas temperature in the
connection at nominal output 314°C
Flue gas mass flow 4,3 g/s
Type approved in accordance with:
European standard EN-13240
NS 3059 (Norway)
BImSchV.2 (Germany)
Art. 15a B-VG (Austria)
Clean Air Act. (UK)
The stove becomes very hot
During operation, certain surfaces of the
stove become very hot and can cause
burn injury if touched. Be aware of the
strong heat radiated through the hatch
glass. Placing flammable material closer
than the safe distance indicated may
cause a fire. Pyre lighting can cause quick
gas ignition with the risk of damage to
property and personal injury.
Connection to chimney
The stove must be connected to chimneys dimensioned for a minimum flue
gas temperature of 400°C.
The external diameter of the connection sleeve is 150 mm.
Normal chimney draw under nominal operation should be between 20-25
Pa close to the connector. The draft is affected both by the length and
area of the chimney, and by how well sealed it is. The recommended
minimum flue length is 3.5 m and its diameter should be Ø130 to Ø150
mm.
A flue with sharp bends and horizontal routing reduces the draught in
the chimney. Maximum horizontal flue is 1 m, on the condition that the
vertical flue length is at least 5 m.
It must be possible to sweep the full length of the flue and the soot
hatches must be easily accessible.
Carefully check that the chimney is sealed and that there is no leakage
around soot hatches and flue connections. See page 40.
The stove meets the requirements for connection to a branched flue pipe.
Supply of combustion air
When a stove is installed in a room, the demand for air supply to the room
increases. Air can be provided indirectly via a vent in the outer wall or via a
duct from the outside that is connected to the connector on the underneath
of the stove. The amount of air needed for combustion is 15 m3/h.
The connector for the combustion air has an external diameter of 67 mm.
When duct routing further than 1 m the pipe diameter must be increased to
100 mm and a correspondingly larger wall vent must be selected.
In hot areas, the duct should be insulated with 30 mm mineral wool with a
moisture inhibiting outer cover. It is also important to seal around the hole
in the wall (or floor) of the lead-in using sealant.
A 1 m length of condensation insulated ducting for combustion air is
available as an accessory.
Facts
Contura reserves the right to change dimensions and procedures described in these instructions
at any time without special notice. The current edition can be downloaded from www.contura.eu
GB
20
!
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
must be at least 1,1 m.
The dimension diagrams only show
the minimum permitted installation
distances for the stove. When con-
necting to a steel flue, also note the
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = minimum height to sloped ceiling
from the centre of the chimney
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS INSTALLATION AGAINST FIREWALLS
C890 / C890G Style
465
1260
2100
93
192
D 354
Combustible roof
365
183
A 1005*
113
B 916*
C 370
46
Ø150
Air inlet Ø67
283
515
585
50
50
Combustible wall
283
515
50
50
585
Fire-retardant wall of
brick or concrete
432**
233
50
200**
700
1000
Fire-retardant wall of
brick or concrete
582
350
350
350
283
100
Combustible wall
2100
E 630
100
GB
21
PRODUCT
Type Wood burning stove
Trade name Contura 890
Intended area of use Heating of rooms in residential buildings
Fuel Wood
MANUFACTURER
Name NIBE AB / Contura
Address Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
VERIFICATION
According to AVCP System 3
European standard EN 13240:2001 / A2:2004 / AC:2007
Test institute Danish Technological Institute, NB 1235
D e c l a r a t i o n o f p e r f o r m a n c e a c c o r d i n g
to Regulation (EU) 305/2011
DECLARED PERFORMANCE
ESSENTIAL CHARACTERISTICS PERFORMANCE HARMONISED TECHNICAL
SPECIFICATION
Fire safety Pass
Fire classification A1
Minimum distance to flammable
materials
Rear: 100 mm
Side: 350 mm
Ceiling: 840 mm
Front: 1100 mm
Floor: 0 mm
Corner: 50 mm
Fire hazard due to burning fuel falling out Pass EN 13240:2001 / A2:2004 / AC:2007
Cleanability Pass
Emissions from combustion CO: 1500 mg/ m3
NOx: 200 mg/ m3
OGC: 120 mg/ m3
PM: 40 mg/ m3
Surface temperatures Pass
Temperature on the handle Pass
Mechanical resistance Pass
Temperature in the space for wood storage Pass
Nominal output 5,0 kW
Efficiency 81,0%
Flue gas temperature at nominal output 259°C
Flue gas temperature in flue spigot 314°C
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Business area manager NIBE STOVES
Markaryd, 1st September 2022
No. C890-CPR-220901
GB
22
EU Declaration of Conformity
Manufacturer NIBE AB / Contura
Address Box 134, Skulptörvägen 10
285 23 Markaryd, Sweden
E-Mail info@contura.se
Website www.contura.eu
Telephone +46 433 275100
THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT:
Trade name Contura 800 Style-series: 810 (W) / 820T / 856 (T/W) / 870 / 886 / 890 (T) / 896
Identification of product www.contura.eu
THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -
THE RELEVANT UNION HARMONIZATION LEGISLATION: THE RELEVANT HARMONIZED STANDARDS:
DIR 2009/125/EC EN 13240:2001/A2:2004/AC:2007
REG (EU) 2015/1185 CEN/TS 15883:2010
REG (EU) 2015/1186
REG (EU) 2017/1369
REG (EU) 305/2011
TECHNICAL DOCUMENTATION
Indirect heating functionality: No
Direct heat output: 5,0 kW
Energy Efficiency Index (EEI): 107,5
Test report 300-ELAB-2412-EN, NB 1235
CHARACTERISTICS WHEN OPERATING WITH THE PREFERRED FUEL
ITEM SYMBOL VALUE UNIT ITEM SYMBOL VALUE UNIT
HEAT OUTPUT USEFUL EFFICIENCY, BASED ON NET CALORIFIC VALUE (NCV )
Nominal heat output: Pnom 5,0 kW Useful efficiency at nominal
heat output η th,nom 81,0 %
AUXILIARY ELECTRICITY CONSUMPTION TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL
At nominal heat output elmax - kW Single stage heat output, no room temperature control Yes
At minimum heat output elmin - kW Two or more manual stages, no room temperature control No
In standby mode elSB - kW With mechanic thermostat room temperature control No
With electronic room temperature control No
With electronic room temperature control plus day timer No
With electronic room temperature control plus week timer No
OTHER CONTROL OPTIONS
Room temperature control, with presence detection No
Room temperature control, with open window detection No
With distance control option
Specific precautions for assembly,
installation, or maintenance.
Fire protection and safety distances to combustible building materials must be observed under all circumstances.
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion
air supply.
FUEL PREFERRED
FUEL OTHER SUITABLE
FUEL η S (%)
EMISSIONS AT NOMINAL HEAT OUTPUT
PM OGC CO NOx
mg/ Nm3 (13% O2)
Wood logs with moisture content ≤25% Yes No 71,0 40 120 1500 200
Compressed wood with moisture content <12% No Yes 71,0 40 120 1500 200
Other woody biomass No No
Non-wood biomass No No
Anthracite and dry steam coal No No
Hard coke No No
Low temperature coke No No
Bituminous coal No No
Lignite briquettes No No
Peat briquettes No No
Blended fossil fuel briquettes No No
Other fossil fuel No No
Blended biomass and fossil fuel briquettes No No
Other blend of biomass and solid fuel No No
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Business area manager NIBE STOVES
Markaryd, January 1, 2022
39
1
2
5
4
3
SE
FR
FI NL
DE
GB
IT
NO
DK
Montering
Om insatsen behöver läggas ned för att
förflyttas bör lösa delar demonteras.
Demontering av eldstadsbeklädnad
beskrivs i slutet av denna anvisning.
1 Galler
2 Rostertallrik
3 Eldstadsbeklädnad (Vermiculit)
4 Typskylt
5 Brasbegränsare
Vor der Montage
Wenn der Einsatz in liegender Position
versetzt werden muss, sind lose Komponenten
zu demontieren. Die Demontage der
Brennraumauskleidung wird am Ende dieser
Anleitung beschrieben.
1 Gitter
2 Rostteller
3 Brennraumauskleidung (Vermiculit)
4 Typenschild
5 Stehrost
r montering
Hvis innsatsen må legges ned for å flyttes,
bør løse deler demonteres. Demontering
av brennplater og hvelv er beskrevet mot
slutten av denne veiledningen.
1 Gitter
2 Rist
3 Brennplater og hvelv (vermikulitt)
4 Typeskilt
5 Kubbestopper
Avant de procéder au
montage
Les éléments non fixés devront être
déposés si l’insert doit être couché
pour être déplacé. Le démontage de
l’habillage du foyer est décrite à la fin de
ce document.
1 Grille
2 Grille de décendrage
3 Habillage du foyer (Vermiculite).
4 Plaque signalétique
5 Pare-bûches
Prior to installation
If the insert needs to be put down to
be moved, loose components should
be removed. Removal of the hearth
cladding is described at the end of these
installation instructions.
1 Grille
2 Grate disc
3 Hearth cladding (Vermiculite)
4 Type plate
5 Fire bars
Før opstilling
Hvis indsatsen skal lægges ned for at
blive flyttet, bør løsdele afmonteres.
Afmontering af ovnbeklædning beskrives
i slutningen af denne vejledning.
1 Gitter
2 Rund askerist
3 Ovnbeklædning (Vermiculite)
4 Typeskilt
5 Brændeholder
Ennen asennusta
Jos tulipesä pitää siirtää kyljellään, irto-
osat pitää irrottaa. Tulipesän verhoilun
irrotus kuvataan ohjeen lopussa.
1 Säleikkö
2 Ruostumaton teräslautanen
3 Tulipesän verhous (vermikuliitti)
4 Tyyppikilpi
5 Suojareunus
Prima del montaggio
Se è necessario smontare l’inserto per
spostarlo, rimuovere prima i componenti
liberi. La procedura di smontaggio del
rivestimento del focolare è descritta alla fine
delle presenti istruzioni.
1 Griglia
2 Griglia del braciere
3 Rivestimento interno del focolare
(vermiculite).
4 Etichetta prodotto
5 Fermalegna
Voorafgaand aan
montage
Als de inzet liggend moet worden verplaatst,
moeten losse onderdelen worden
gedemonteerd. De demontage van de
haardbekleding wordt beschreven aan het
eind van deze instructies.
1 Rooster
2 Roosterschijf
3 Haardbekleding (vermiculiet)
4 Typeplaatje
5 Houtvanger
40
Ø ca 180 mm
Ø ca 180 mm
3
2
1
5
4
50
SE
DE
NO
FR
GB
DK
FI
IT
NL
Bakåtanslutning till skorsten
Rückseitiger Anschluss an einen Schornstein
Bakmontering til skorstein
Raccordement par l’arrière à la cheminée
Rear connection to chimney
Tilslutning bagud til skorsten
Liitäntä taaksepäin savupiippuun
Collegamento alla canna fumaria dal retro della stufa
Achterwaartse aansluiting op een schoorsteen
41
15-20 mm
SE
DE
NO
FR
GB
DK
FI
IT
NL
Toppanslutning till skorsten
Varmluftsgallret måste vara monterat innan skorstenen toppansluts.
Oberseitiger Anschluss an den Schornstein
Das Warmluftgitter muss montiert sein, bevor ein
Schornsteinanschluss an der Oberseite erfolgt.
Toppmontering til skorstein
Varmluftsgitteret må være montert før skorsteinen topptilkobles.
Raccordement par le haut
Monter la grille d’air chaud avant le raccordement à la cheminée par
le haut.
Top connection to the chimney
The hot air grille must be installed before chimney top connection.
Toptilslutning til skorsten
Varmluftristen skal være monteret, før skorstenen toptilsluttes.
Liitäntä ylöspäin savupiippuun
Lämminilmaritilä pitää asentaa ennen savupiipun liitäntää ylöspäin.
Collegamento alla canna fumaria dal piano
della stufa
Prima di collegare la canna fumaria al piano della stufa, assicurarsi
che la griglia dell’aria calda sia montata.
Bovenaansluiting op een schoorsteen
Het heteluchtrooster moet zijn gemonteerd, voordat de schoorsteen
op de bovenaansluiting wordt aangesloten.
Toppanslutning till isolerad skorsten
Spalt Min 15 mm, Max 20 mm.
Oberer Anschluss an isoliertem Schornstein
Spalt: mind. 15 mm, max. 20 mm.
Toppmontering til isolert skorstein
Spalte min. 15 mm, maks. 20 mm.
Raccordement par le haut à une cheminé isolée
Espace min.15 mm, min. 20 mm.
Top connection for insulated chimney
Gap Min. 15 mm, Max. 20 mm.
Toptilslutning til isoleret skorsten
Spalte min. 15 mm, maks. 20 mm.
Liitäntä ylöspäin eristettyyn savupiippuun
Rako min 15 mm, maks 20 mm.
Collegamento alla canna fumaria isolata dal
piano della stufa
Luce min 15 mm, max 20 mm.
Bovenaansluiting op een geïsoleerde schoorsteen
Ruimte min. 15 mm, max. 20 mm.
SE
DE
NO
FR
GB
DK
FI
IT
NL
42
HK HK
40 mm
1 2
HK
40 mm
HK
40 mm
3 4
SE
DE
NO
FR
GB
DK
FI
IT
NL
Tilluft
Zuluft
Tilluft
Arrivée d’air
Supply
Forbrændingsluft
Tuloilma
Alimentazione dell’aria
Toevoerlucht
43
13
13
VANADI UM
No. 7
CHROME
2
1
44
5
4
3
45
x2
7
6
18 mm
46
2
3
1
47
1
3
2
2
1
SE
DE
NO
FR
GB
DK
FI
IT
NL
Luckan kan srras i öppet läge, med hjälp av låsarmen på kaminens
vänstra sida.
Uppställning av luckan, vid städning/service
Mithilfe des Armes an der linken Seite des Kamins kann die Tür in
ihrer geöffneten Stellung arretiert werden.
Låsing av døren i åpen posisjon, ved rengjøring/
service
Døren kan låses i åpen posisjon, ved hjelp av låsearmen på venstre
siden av ovnen.
Placement de la porte, pour le nettoyage et/
ou l’entretien
La porte peut être verrouillée en position ouverte, à l’aide du levier de
verrouillage situé sur le côté gauche du poêle.
The door can be secured in the open position using the locking lever
on the left side of the stove.
Door in open position, for cleaning/service
Spærring af lågen, ved rengøring/service
Lågen kan spærres i åben position ved hjælp af låsearmen på
venstre side af brændeovnen.
Luukun asettaminen puhdistusta/huoltoa varten
Luukku voidaan lukita avattuun asentoon takan vasemmalla
puolella olevalla lukitusvarrella.
Lo sportello può essere bloccato in posizione aperta con una levetta di
blocco posta sotto la parte sinistra della stufa.
Bloccaggio dello sportello per la pulizia/
la manutenzione
De deur kan in geopende stand worden vastgezet met behulp van de
vergrendeling aan de linkerzijde van de kachel.
Plaatsen van de deur, bij schoonmaken/onderhoud
Aufstellen der Tür für Reinigung und Service
48
1
3
2
4
1
2
SE
DE
NO
FR
GB
DK
FI
IT
NL
Demontera eldstadsbeklädnaden (Vermiculit)
So demontieren Sie die Brennraumauskleidung (Vermiculit)
Slik demonterer du ildstedsbekledningen (Vermikulitt)
Voici comment démonter l’habillage du foyer (Vermiculite)
How to remove the hearth surround (Vermiculite)
Sådan afmonterer du ovnbeklædningen (Vermiculite)
Näin irrotat tulipesän verhouksen (vermikuliitti)
Come smontare il rivestimento del focolare (vermiculite)
Zo demonteert u de kachelbekleding (vermiculiet)
Handle with care!
!
49
1
2
1
2
1
2
5
7
9
6
8
50
1
2
11 12
10
811392 IAV SE-EX C890 Style-7
2023-10-23
NIBE AB · Box 134 · 285 23 Markaryd · Sweden
contura.eu
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Contura Contura C890G Manuale utente

Categoria
Stufa a legna
Tipo
Manuale utente
Questo manuale è adatto anche per