Defender MIDI 4C Manuale utente

Tipo
Manuale utente
USER´S MANUAL
BEDIENUNGSANLEITUNG
MANUEL D´UTILISATION
MANUAL DE USUARIO
INSTRUKCJA OBSŁUGI
MANUALE D´USO
MIDI 5 2D / MIDI 5 / MIDI 4C
SERIES
SERIES
2
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
SAFETY INFORMATION page 3
GENERAL DESCRIPTION page 4
CARE AND MAINTENANCE page 4
SETUP page 5
DEFENDER® MIDI 5 2D page 6
DEFENDER® MIDI 5 page 10
DEFENDER® MIDI 4C page 12
REPLACEMENT PARTS AND ACCESSORIES page 14
DISPOSAL page 14
LIMITED WARRANTY page 15
LIMITATION OF LIABILITY page 16
REQUESTING WARRANTY-SERVICE page 16
TABLE OF CONTENTS
Always up-to-date online at: defender-protects.com
3
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
SAFETY INFORMATION
All cable protectors in the DEFENDER® SERIES are designed to protect cables of all types against damage, and
visitors as well as operators from injuries by tripping. To ensure these goals, the following safety instructions for
use of the cable protectors must be observed:
This user's manual is an integral part of the product and must be read carefully before use.
DEFENDER® cable protectors may only be used in accordance with their intended purposes and maximum
load-bearing capacity. Valid parameters can be found in the detailed description of the respective product
variant.
DEFENDER® cable protectors are designed for use on firm and level ground. The load specified in the detailed
descriptions is achieved only on level and solid ground. Load-bearing capacity may be greatly reduced on
uneven or soft ground.
Please note that additional markings / hazard warnings or even permits may be required when using cable
protectors on public thoroughfares, walkways, etc.
• Use DEFENDER® cable protectors only with original replacement parts and accessories.
HAZARD
Incorrect insulation Life-threatening danger due to electric shock Only use cables that comply
with the prescribed installation regulations with regard to voltage, current, insulation material, load
capacity, etc.
Caution! Tripping hazard.
ESPECIALLY IMPORTANT:
• Do not modify the product in ANY way. Modifications to the DEFENDER® cable protector
change the product’s characteristics, reduce its protective effect, and lead to a loss of the warranty.
• Do NOT bridge over ANY ditches, shafts, stairs, or similar depressions.
• Do NOT support pedestals, scaffolding, beams, and similar on the cable protectors.
• Do NOT run rigid gas lines in the cable protectors.
• Do NOT run cables with a voltage >500V in the cable protectors.
• Fill the cable ducts up to a max. of 70% to the underside of the cover.
To ensure that the trip protection does not itself become a tripping hazard:
• Connect the cable protectors in complete sections.
• Check that the connectors are flush for each installation.
• Check that the lid closures function for each installation.
• Make sure that the lid closure snaps securely into the base.
• Keep the hinge area and lid closure clean.
• Remove any excess lubricant from the hinges after care.
4
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
GENERAL DESCRIPTION
Cable protectors are used to protect floor cables that are not permanently installed, for example at trade shows,
markets and in the event industry. Cable protectors are used to prevent people from tripping.
You have chosen the DEFENDER® SERIES and thus made the best choice when it comes to protecting your
cables and people. DEFENDER® cable protectors are characterised by:
DEKRA-certified safety (OFFICE-85160, COMPACT-85100, NANO-85150, MINI-85200, MIDI 4-85301,
MIDI 5-85300, 3-85002, XXL-85500, ULTRA L-85600, ULTRA L2-85601)
TÜV SÜD-certified safety (MICRO 2-86100, MINI-85200, MIDI 5-85300)
• Patented with self-cleaning hinge (EU Patent No.: EP1366550)
• Development and production in Germany
• Fire protection class E according to DIN EN 13501-1 (B-s1 pending)
• Stringent raw material and production controls
Very stable, tear-resistant and 100% recyclable plastic
• Resistance to oil, acid and petrol
Temperature resistance from -30°C to +60°C
A shore A hardness of 88 ± 4
A wide range of product variants with coordinated system elements
A wide range of uses, from construction sites to offices
CARE AND MAINTENANCE
All cable protectors in the DEFENDER® SERIES are made of extremely sturdy, non-breakable plastic (polyure-
thane). The protectors can be easily cleaned, even using a steam jet cleaner. In order to ensure trouble-free
functioning, however, the hinge area and the lid closure should always be kept clean; slightly lubricate hinges
and closure on a regular basis. For this, we recommend using a commercially available Teflon or silicone spray.
Wipe off excess lubricant after application to avoid any risk of slipping.
5
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
SETUP
The cable protectors from the DEFENDER® series are easy and safe to set up. Surfaces, edges and corners are
designed in such a way that there is no danger of injury. Cable protectors with a weight up to 20 kg can be
transported safely by one person. Cable protectors weighing more than 20 kg can be transported safely by two
people.
Each cable protector has connectors and corresponding sockets that enable you to connect cable protectors in
the same series endlessly with one another. Generally, sections are stable enough to be walked on or driven over
without any additional precautions. To find the right cable protector for your respective requirements, please see
the attached detailed product description for the load-bearing capacity and use.
For the product versions DEFENDER® 3 AND ULTRA L 2, special holes for floor anchoring are provided. If com-
plete sections from these product variants are exposed to increased requirements, so that there is a risk of the
section shifting during use, we recommend additionally anchoring the section to the ground or floor. Please note
that additional markings / hazard warnings or even permits may be required when using cable protectors on
public thoroughfares, walkways, etc.
The load-bearing capacity specified in the detailed descriptions is achieved only on level and solid ground.
Load-bearing capacity may be greatly reduced on uneven or soft ground. In such cases, you should conduct
appropriate load tests before using the protector. We guarantee the load-bearing capacity of our cable protectors
only with proper use of unmodified products on firm and level ground.
DEFENDER® cable protectors help protect pipes (e.g. water/sewage) and low voltage cables up to 500 V
(e.g. communication/control cables/power supply). The cable protectors are NOT suitable for rigid gas pipes.
When using fragile couplings and connectors within the connected section, make sure there is sufficient space
to either side and above. Each user is responsible for the manner of installation and selection of cables to be
protected with the help of the DEFENDER® cable protectors.
After installation (except for the COMPACT and OFFICE models), the lids can be opened by pulling them upward.
They snap into the open position automatically and stay open until you close them again, thus making it easier to
run your cables. After running your cables, close the lid. When doing so, make certain that the lid closure snaps
into the base securely. This is the only way to ensure that the lid stays closed under load.
6
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
DEFENDER® MIDI 5 2D
The wheelchair-friendly and modular DEFENDER® MIDI 5 2D system was developed based on our popular
DEFENDER® MIDI. It consists of a DEFENDER® MIDI 5-compatible mid-section and a flat ramp that can be freely
expanded and combined as required, both in length and width. For extremely simple handling. To ensure
wheelchairs can safely cross cable protectors, ensure that the minimum width of the transversable
cable protector is not less than 2000 mm.
MIDI 5 2D M / MIDI 5 2D M BLUE
MIDI 5 2D HV
1000 x 325 x 54 mm
500 x 325 x 54 mm
Weight: 11.5 kg
Weight: 5.8 kg
Load-bearing capacity: approx. 5 t / 7.9 × 7.9 inches. In general, every vehicle licensed for use on public roads
may drive over this protector.
Areas of use: Exhibitions / walkways / marketplaces / Christmas markets / workshops / warehouses / shop-
ping centers / department stores / etc.
MIDI 5 2D R 1000 x 430 x 54 mm Weight: 9.6 kg
Load-bearing capacity: approx. 5 t / 7.9 × 7.9 inches. In general, every vehicle licensed for use on public roads
may drive over this ramp.
Areas of use: Exhibitions / walkways / marketplaces / Christmas markets / workshops / warehouses / shop-
ping centers / department stores / etc.
MIDI 5 2D SET BLU 1000 x 1185 x 54 mm Weight: 27.2 kg
Load-bearing capacity: approx. 5 t / 7.9 × 7.9 inches. In general, every vehicle licensed for use on public roads
may drive over this ramp.
Areas of use: Exhibitions / walkways / marketplaces / Christmas markets / workshops / warehouses / shop-
ping centers / department stores / etc.
DEFENDER® MIDI 5 2D SET BLU
869300SETBLU
7
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
869300
DEFENDER® MIDI 5 2D M
DEFENDER® MIDI 5 2D BLU HVDEFENDER® MIDI 5 2D HV
869350BLU869350
DEFENDER® MIDI 5 2D R
869301
DEFENDER® MIDI 5 2D M BLUE
869300BLUE
8
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
AB
I
J
=
ENGINEERING DRAWING
H
G
E F
A325 mm / 12.8" D54 mm / 2.1" G 38.1 mm / 1.5" J 6 °
B 398 mm / 15.7" E 34.5 mm / 1.4" H 397.7 mm / 15.7"
C1000 mm / 39.4" F 4°C I 430 mm / 16.9"
=
=
D
C
9
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
869301ASET
DEFENDER® MIDI 5 2D Adapter set
(Connector plugs)
869300 AE F (Endpiece Female)
DEFENDER® MIDI 5 2D Adapter
869300 AE M (Endpiece Male)
DEFENDER® MIDI 5 2D Adapter
Accessories:
10
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
DEFENDER® MIDI 5
The DEFENDER® MIDI was developed as a solution for applications between the DEFENDER® COMPACT and
DEFENDER® 3. This cable crossover features five cable channels, moulded connectors and a lower height and
lighter weight than the DEFENDER® 3. The load bearing capacity is similar to that of the DEFENDER® 3!
MIDI 5
MIDI 5 BLK
870 x 538 x 55 mm Weight: 13.5 kg
Load-bearing capacity: ca. 5 t on a surface area of 20 x 20 cm. Generally, any street-legal vehicle can drive
over this crossover.
Areas of use: Exhibitions / walkways / marketplaces / Christmas markets / workshops / warehouses /
shopping centers / department stores / etc.
85300 85300BLK
85305SET
(Wheelchair Ramp Set)
DISCONTINOUED
While stock last
11
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
AB
C
D
E
F
G
ENGINEERING DRAWING
Accessories:
85310BLK
DEFENDER® MIDI 5 C (45° curve)
A 55 mm / 2.2" C 34 mm / 1.3" E 870 mm / 34,3" G 942 mm / 37"
B 36 mm / 1.4" D 538 mm / 21.2" F 54 mm / 2.1"
DEFENDER® MIDI 5 C (45° curve)
85310
85308
DEFENDER® MIDI ER (End ramp)
12
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
DEFENDER® MIDI 4C
The Defender® MIDI 4C cable crossover has three cable channels measuring 34 x 36 mm plus a wide hose chan-
nel (80 x 36 mm), making it the ideal solution if a pressure hose has to run parallel to individual sound, light and/
or network cables.
MIDI 4C 87O x 538 x 55 mm Weight: 13.5 kg
Load-bearing capacity:
approx. 5 t on an area of 20 x 20 cm. Not to be used in street traffic.
However, automobiles may still drive slowly over the protector.
Areas of use:
Exhibitions / walkways / marketplaces / Christmas markets / workshops / warehouses / shopping centers /
department stores / etc
85301 85301BLK
85305SET
(Wheelchair Ramp Set)
DISCONTINOUED
While stock last
13
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
F
G
H
AB
CD
E
ENGINEERING DRAWING
Accessories:
A 55 mm / 2.2" C 34 mm / 1.3" E 538 mm / 21.2" G 52 mm / 2.0"
B 36 mm / 1.4" D 80 mm / 3.2" F 870 mm / 34.3" H 942 mm / 37.1"
85308
DEFENDER® MIDI ER (End ramp)
14
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
REPLACEMENT PARTS AND ACCESSORIES
The DEFENDER® SERIES consists of a wide range of product variants with coordinated system elements, and
covers applications from construction sites to offices.
A selection of frequently used system elements can be found in the respective detailed description of this user's
manual.
A complete list of system elements, replacement parts and accessories can be found at http://www.defender-
protects.com
DISPOSAL
All cable protectors in the DEFENDER® SERIES are made of extremely sturdy, non-breakable plastic (polyure-
thane and thermoplastic polyurethane). Polyurethane is a valuable raw material, 100% recyclable and is not
considered hazardous waste, thus it is not subject to any specific disposal requirements. The cable protectors
will be accepted either by recycling centres and recycling yards or other landfills and waste incinerators.
15
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
LIMITED WARRANTY
This warranty extends to the DEFENDER® branded product you purchased from Adam Hall. The statutory warranty
rights against the vendor shall not be affected by this warranty. Rather, this warranty gives you additional independent
claims against Adam Hall.
With this warranty, Adam Hall ensures that products you have purchased from Adam Hall or Adam Hall partners,
under normal use, are free of defects in material or workmanship for a period of 5 years from the date of
purchase. The warranty period begins on the date of purchase. In order to assert a claim for warranty service,
the proof of date of purchase is provided by the receipt bearing the date of purchase or the date of purchase on
the delivery note. You are entitled to warranty service under the conditions and provisions set out in this document,
if a repair within the warranty period is required.
This warranty applies only to the original purchaser of the products supplied by Adam Hall and is not transferable
to any person to whom the property is transferred by the original purchaser.
Within the warranty period, the defective parts or the product from Adam Hall will be repaired or replaced. Under
the terms of this warranty, all the replaced or removed components become the property of Adam Hall.
In the unlikely event that a product acquired from Adam Hall, repeatedly exhibits a defect, Adam Hall may decide,
at its discretion, to replace this product with a comparable product of at least the same performance.
Adam Hall does not guarantee that the operation of this product will be uninterrupted or error-free. Adam Hall
accepts no responsibility for any damage due to incorrect compliance with the instructions received in the delivery.
This warranty does not extend to:
wearing parts (eg battery, tubes).
devices that have had their serial number removed or damaged, or failed as a result of an accident
inappropriate or abusive use or other external causes
devices that were not used in accordance with the operating parameters defined in the user documentation
shipped with the product
devices that have been repaired using parts not made or distributed by Adam Hall
devices that have been serviced, modified or repaired by someone other than Adam Hall or an authorised
service partner.
These terms and conditions constitute the complete and exclusive warranty agreement between you and Adam
Hall regarding the Adam Hall branded product you have purchased.
This warranty is valid only within Europe. Outside of Europe please contact our official distributors.
16
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
Printing errors and mistakes, as well as technical or other changes are reserved!
LIMITATION OF LIABILITY
If your Adam Hall branded hardware product fails to work as warranted above, your sole and exclusive remedy
shall be repair or replacement. Adam Halls’ maximum liability under this limited warranty is expressly limited
to the lesser of the price you have paid for the product or the cost of repair or replacement of any hardware
components that malfunction in conditions of normal use.
Adam Hall is not liable for any damages caused by the product or the failure of the product, including any lost
profits or savings or special, incidental, or consequential damages. Adam Hall is not liable for any claim made by
a third party or made by you for a third party.
This limitation of liability applies whether damages are sought, or claims are made, under this Limited Warranty
or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limi-
tation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if
you have advised Adam Hall of an authorized representative of Adam Hall of the possibility of any such damages.
This limitation of liability however, will not apply to claims for personal injury.
This Limited Warranty gives you specific legal rights. You may also have other rights that may vary from state to
state or from country to country. You are advised to consult applicable state or country laws for a full determina-
tion of your rights.
REQUESTING WARRANTY-SERVICE
To request warranty service for the product, contact Adam Hall GmbH, Adam-Hall-Str. 1, 61267 Neu Anspach
(Germany) / Email: [email protected] / +49 (0)6081 / 9419-0 or the Adam Hall authorized reseller from which
you purchased the product.
17
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
Printing errors and mistakes, as well as technical or other changes are reserved!
18 19
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
INHALTSVERZEICHNIS
Auch immer aktuell im Internet unter: defender-protects.com
SICHERHEITSHINWEISE Seite19
ALLGEMEINE BESCHREIBUNG Seite20
INSTANDHALTUNG UND PFLEGE Seite20
AUFBAU Seite21
DEFENDER® MIDI 5 2D Seite22
DEFENDER® MIDI 5 Seite26
DEFENDER® MIDI 4C Seite28
ERSATZTEILE UND ZUBEHÖR Seite30
ENTSORGUNG Seite30
HERSTELLERGARANTIE Seite31
HAFTUNGSBESCHRÄNKUNG Seite32
INANSPRUCHNAHME DER GARANTIE Seite32
18 19
ENGLISH DEUTSCH FRANCAIS ESPAÑOL POLSKI ITALIANO
SERIES SERIES
SICHERHEITSHINWEISE
Alle Kabelbrücken der DEFENDER® Serie verfolgen das Ziel, auf dem Boden liegende Leitungen vor Beschädigun-
gen und Besucher sowie Veranstalter vor Verletzungen durch Stolpern zu schützen. Um diese Ziele sicher
zu erreichen, sind folgende Sicherheitshinweise zum Einsatz der Kabelbrücken zu beachten:
• Diese Bedienungsanleitung ist Bestandteil des Produktes und muss vor Gebrauch aufmerksam gelesen werden.
DEFENDER® Kabelbrücken dürfen nur gemäß ihrer jeweils vorgesehenen Einsatzbereiche und Belastungsgren-
zen eingesetzt werden. Die gültigen Parameter finden Sie in der Detailbeschreibung der jeweiligen Produktvari-
ante.
DEFENDER® Kabelbrücken sind für den Einsatz auf festem und ebenem Grund vorgesehen. Die in den Detailbe-
schreibungen angegebene Belastung wird nur auf ebenem und festem Grund erreicht. Bei unebenen oder gar
weichen Untergründen kann die Belastbarkeit stark abnehmen.
Beim Einsatz von Kabelbrücken auf öffentlichen Straßen, Gehwegen etc. können zusätzliche Kennzeichnungen/
Gefahrenhinweise oder auch Genehmigungen erforderlich sein.
Verwenden Sie DEFENDER® Kabelbrücken nur mit Original Ersatzteilen und Zubehör.
GEFAHR
Fehlerhafte Isolierung Lebensgefahr durch elektrischen Schlag Verwenden Sie nur Leitungen,
die den vorgeschriebenen Installationsvorschriften hinsichtlich Spannung, Strom, Isolationsmaterial,
Belastbarkeit etc. entsprechen.
Vorsicht! Stolpergefahr.
BESONDERS WICHTIG:
• KEINE Veränderungen am Produkt vornehmen. Modifikationen der DEFENDER® Kabelbrücken
verändern die Produkteigenschaften, vermindern die Schutzwirkung und führen zu Garantieverlust.
• KEINE Gräben, Schächte, Stufen oder ähnliche Vertiefungen überbrücken.
• KEINE Podeste, Gerüste, Traversen und ähnliches auf den Kabelbrücken abstützen.
• KEINE starren Gasleitungen in den Kabelbrücken verlegen.
• KEINE Kabel mit einer Spannung >500 V in die Kablebrücken verlegen
Die Kabelkanäle nur max. 70 % bis Deckelunterseite befüllen. Bitte beachten Sie auch die
individuellen Spezifikationen bei den einzelnen Kabelbrücken
Damit der Stolperschutz nicht selbst zu Stolperfalle wird:
Verbinden Sie die Kabelbrücken zu geschlossenen Linien.
• Prüfen Sie bei jeder Verlegung die Verbinder auf bündigen Sitz.
• Prüfen Sie bei jeder Verlegung die Deckelverschlüsse auf Funktion.
Achten Sie darauf, dass der Deckelverschluss fest in der Basis einrastet.
• Halten Sie den Scharnierbereich und den Verschluss sauber.
• Entfernen Sie nach Pflege der Scharniere überschüssiges Schmiermittel.
20 21
ENGLISHDEUTSCHFRANCAISESPAÑOLPOLSKIITALIANO
SERIES SERIES
ALLGEMEINE BESCHREIBUNG
Kabelbrücken dienen zum Schutz von nicht permanent installierten, bodenliegenden Leitungen, zum Beispiel
bei Messen, Märkten und im Veranstaltungsbereich. Kabelbrücken dienen zum Schutz von Personen durch die
Vermeidung von Stolperfallen.
Sie haben sich für die DEFENDER®-Serie entschieden und somit die beste Wahl zum Schutz von Leitungen und
Personen getroffen. DEFENDER® Kabelbrücken zeichnen sich aus durch:
DEKRA zertifizierte Sicherheit (OFFICE-85160, COMPACT-85100, NANO-85150, MINI-85200,
MIDI 4-85301, MIDI 5-85300, 3-85002, XXL-85500, ULTRA L-85600, ULTRA L2-85601)
TÜV SÜD zertifizierte Sicherheit (MICRO 2-86100, MINI-85200, MIDI 5-85300)
• Patentierte selbstreinigende Scharniere (EU Patent No.: EP1366550)
• Entwicklung und Herstellung in Deutschland
• Brandschutzklasse E nach DIN EN 13501-1 (B-s1 beantragt)
• Strengste Rohstoff- und Produktionskontrollen
• Sehr stabilen, reißfesten und 100% recycelbaren Kunststoff
• Beständig gegen Öl, Benzin und kurzfristigen Kontakt mit Lösungsmitteln
• Einen Arbeitsbereich von ca. -30°C bis +60°C
• Einen Härtebereich von 88 Shore-A ± 4
• Eine Vielfalt von Produktvarianten mit abgestimmten Systemelementen
• Ein breites Einsatzspektrum von Baustellen bis zu Büroräumen
INSTANDHALTUNG UND PFLEGE
Alle Kabelbrücken der DEFENDER®-Serie werden aus einem sehr stabilen und reißfestem Kunststoff (Polyurethan)
gefertigt. Die Brücken können ohne Probleme, gerne auch unter Zuhilfenahme eines Dampfstrahlreinigers, gesäu-
bert werden. Um immer eine einwandfreie Funktion zu gewährleisten, halten Sie den Scharnierbereich sowie den
Verschluss sauber und schmieren Sie Scharnier und Verschluss regelmäßig leicht. Hierzu empfehlen wir Ihnen ein
handelsübliches Teflon- oder Silikon-Spray. Reiben Sie überschüssiges Schmiermittel nach der Anwendung ab,
um Rutschgefahr vorzubeugen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Defender MIDI 4C Manuale utente

Tipo
Manuale utente