Dometic DHT-L Series Holding Tanks Guida d'installazione

Tipo
Guida d'installazione
DHT-L Series
Holding Tanks
EN
DE
FR
ES
NL
IT
FI
SV
DA
NO
Holding Tank System
Instruction manual.................... 8
Schmutzwassertank-System
Einbauanleitung..................... 17
Système de réservoir d'eaux noires
Mode d'emploi .....................25
Sistema de depósito de retención
Manual de instrucciones..............34
Vuilwatertank-systeem
Gebruiksaanwijzing..................43
Impianto del serbatoio di ritenzione
Manuale di istruzioni .................51
Keräyssäiliöjärjestelmä
Ohjekirja...........................59
Avloppstank system
Bruksanvisning .....................67
Lagertanksystem
Instruktionsvejledning ................75
Oppbevaringstank-system
Brukerhåndbok .....................83
2
Dometic Holding Tanks
1
390
350
400
400
350
350
350
350
1200
1200
800
660
460
390
350
DHT42L
DHT88L
DHT110L
DHT137L
DHT61L
3
2
3
Dometic Holding Tanks
1
23
4
5
6
7
7
1 1
1
A
C
B
D
4
5
6
4
Dometic Holding Tanks
1
1
23
4
6
5
2
A
B
A B
12
34
5
7
8
9
Dometic Holding Tanks
4
5
1
2
3
4
1
2
3
VF
1
2
3
6
10
11
Dometic Holding Tanks
1
2
3
4
A
B
C
7
12
13
Dometic Holding Tanks
8
Dometic Holding TanksNotes on using the manual
EN
Table of contents
1 Notes on using the manual ....................................................8
2 General safety instructions ....................................................8
3 Intended use ...............................................................9
4 Components and Functions ............................................... 9 - 10
5 Tank Installation........................................................ 10 - 11
6 Hose Installation ....................................................... 11 - 14
7 Cleaning and Winterizing.....................................................14
8 Specications .............................................................14
9 Warranty and Product Liability ............................................ 15 - 16
1 Notes on using the manual
Note
Supplementary information for operating the device.
fig. 1, page 3 : This refers to an element in an illustration. In this example, item 1 in
gure 2 on page 3.
2
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and
impair the function of the device.
Caution!
Before working on any part of an existing or newly installed component of a sanitary system,
be sure all electrical power to system is turned off and all seacocks are in CLOSED or OFF
position. Failure to do so can result in ooding, which can cause the loss of life or property.
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
Faulty assembly or connection
Damage to the system or any components from mechanical inuences, misuse or abuse
Alterations to the holding tank system without express permission from the manufacturer
Use for purposes other than those described in the operating manual
When using electrical devices to install this system, observe the following safety information to
protect against:
Electric shock
Fire hazards
• Injury
9
Dometic Holding Tanks
Note
Each xture that discharges greywater into a holding tank must have a water trap seal to
prevent odor from entering the living space.
Note
Only one outlet tting (1 or 2) can be converted to an inlet tting if required. One outlet
must remain in original location on tank. Inlet tting on opposite side of tank (6) should
not be converted to outlet tting.
Caution!
Boat operator must know local sewage discharge regulations.
3 Intended use
Dometic holding tank systems provide high-quality, long-lasting equipment to store toilet waste-
water onboard a vessel, efciently discharge the efuent at approved disposal facilities or in
unrestricted waters, and prevent sewage from spoiling sensitive waters, such as marinas, near
swimming beaches or over shellsh beds.
Dometic holding tanks may also be used for greywater use (water from showers, basins, clothes
washers, etc.), provided that greywater is the only type of water entering the tank.
4 Components and Functions
Items in fig.
page 3 Description
1 38 mm (1.5 in.) ID outlet hose connection to deck tting or seacock
2 38 mm (1.5 in.) ID outlet hose connection to deck tting or seacock
3
inspection port or location for optional level indicator probe cap
4 16 mm (0.625 in.) ID ventilation hose connection
5 vacuum relief valve
6 38 mm (1.5 in.) ID inlet hose connection from toilet
7 integrated mounting feet (4 locations)
2
Intended use
Leakproof design. Dometic holding tank ttings are connected on top of the tank, eliminating the
possibility of leaking due to faulty connections below the level of the tank contents.
Odor-free, long-lasting performance. Tanks are made of linear low density polyethylene, the
best material for holding tank construction because of its resistance to corrosion and odor
permeation. It will last longer than the life of a typical hull.
Implosion protection. Heavy-duty tank and vacuum relief valve combine to prevent potential
damage from dockside pumps that may operate at high levels of vacuum.
3.1 Benefits of Dometic Holding Tanks
10
Dometic Holding TanksComponents and Functions
Pre-installed inlet and two outlets for dockside and seacock connections
Inlet and outlet ttings rotate to facilitate hose connection from virtually any direction (g. 3 D,
page 3)
Discharge tubes have special non-clogging design
Vacuum relief valve protects tank from over-pressure collapse
Extra ttings allow tank conversion to various inlet and outlet congurations
– one inlet, two outlets (g. 3 A, page 3)
– one inlet, one outlet on same side of tank (g. 3 B, page 3)
– one inlet, one outlet on different sides of tank (g. 3 C, page 3)
Meets ISO 8099 requirements
4.1 Features
5 Tank Installation
Determine properly located surface that will support the entire area of the tank. If a mounting
surface needs to be fabricated, use marine grade plywood at least 13 mm thick. If installing with
restraining straps, include toe blocks on mounting surface (g. 4 B, page 4).
Integrated Mounting Feet Installation (g. 4 A, page 4)
In the four mounting feet locations around bottom of tank, use at least 6 mm dia. (#12) fasteners
with 19 mm maximum dia. (0.75 in.) washers to fasten tank to surface.
Restraining Strap Installation (g. 4 B, page 4)
With restraining straps of 31 mm (1.25 in.) maximum width, fasten straps over top of tank to
mounting surface on both sides of tank, positioning the straps within the channels on the tank.
5.1 Choose a location for the holding tank
5.2 Prepare a mounting surface
5.3 Install tank on mounting surface
Caution!
The holding tank should not be exposed to temperatures above 45°C (120°F). Do not place
tank near heat sources such as engine manifolds, water heaters, generators, etc.
Caution!
Do not install tank on projections, such as fastener heads, which could puncture the tank.
Do not allow holding tank to block free ow of bilge water.
A holding tank should be positioned as low in the hull as possible. Most connecting hoses and pipes
should slope downward toward the tank to permit gravity drainage and prevent possible hose odor
permeation. Hose connected to an overboard discharge pump should drain away from the tank.
In addition to dimensions of tank (g. 1 , page 2), allow 16 cm (about 6 inches) above tank to
easily make plumbing connections.
SERVICE ACCESS – Because Dometic holding tanks may require minimal service in normal
operation, the tank must be installed so that there is easy access to the inspection port.
3
3
1
4
4
4
3
3
11
Dometic Holding Tanks Tank Installaiton
6 Hose Installation
Dometic holding tanks are pre-assembled with 38 mm (1.5
in.) and 16 mm (0.625 in.) ID hose connection ttings. If your
sanitation system uses hoses other than these sizes, you may
either use tting adapters to convert from the Dometic tting
sizes to your current hose, or install new hose to match the
Dometic tank ttings.
If installing new hose, Dometic OdorSafe® Plus sanitation hose
provides the best protection against hose odor permeation for
toilet and holding tank discharge lines, and is available in 38
mm (1.5 in.) ID only. Dometic MaxFlex™ hose is available in all
the sizes that are listed in the Sanitation, Vent Hose Size Guide
(right), and provides high-quality odor-resistance.
Diagram A indicates an incorrect installation with multiple hose runs that can retain trapped liquids
and cause hose odor permeation. Diagram B shows a simplied, highly efcient plumbing system
that can be achieved with Dometic’s specially integrated holding tank system design.
6.1 Hose selection
6.2 Hose layout
Sanitation, Vent Hose Size
Guide (g. 5 , page 4)
Key to (fig. , page 4)
Item Description
138 mm (1.5 in.) ID
sanitation hose
225 mm (1 in.) ID
sanitation hose
319 mm (0.75 in.) ID
vent hose
416 mm (0.625 in.) ID
vent hose
Ref. Description
A complicated plumbing layout
B simple plumbing layout
1 problem hose
2 holding tank
6
Note
Fasteners (lag bolts, screws, washers, etc.) and restraining straps are not supplied with
Dometic holding tank.
Ref. Description
3 macerator pump
4 seacock (overboard discharge)
5 wye valve
6 discharge pump
12
Dometic Holding TanksHose Installation
OdorSafe Plus hose or rigid pipe should be installed
on hose runs that may retain sewage.
Some existing seacocks and through-hull discharge
ttings may be 25 mm in diameter. If so, use a 38
mm x 25 mm reducer and 25 mm MaxFlex
sanitation hose. Item Description
1Discharge hose to deck tting
(38 mm ID)
2Discharge hose to seacock and
discharge tting (38 mm ID)
3 Discharge pump
4 Holding tank
Note
A valve with a lockable handle must be on all
through-hull ttings that emit sewage.
Note
Maintenance valves must be installed in any
piping runs which retain liquid and are
connected to components which require
periodic servicing.
Discharge Hoses (fig. 8 , page 5)
8
Caution – Flooding Hazard!
If the toilet, holding tank or any components are connected to any through-hull ttings,
properly installed seacocks must be installed in all piping connected to the through-hull
ttings. Seacocks must be easily accessible to all users of the system. All valves must be
full-bore valves and of marine (corrosion resistant) quality. Screw-to-close gate valves are
not recommended. Failure to do so can result in ooding, which can cause the loss of life
and property.
Caution – Flooding Hazard!
Some marine practices and/or standards require the installation of a properly positioned
ventilated (vented) loop in the discharge piping to prevent back-siphonage of seawater
into the holding tank. It is up to the system installer and boat owner to select appropriate
means of preventing backow into the holding tank.
Different marine toilet manufacturers use different sizes
of outlets. Check outlet size of toilet(s) or size of toilet
discharge hose(s) that will connect to holding tank.
If connecting previous toilet discharge hose to new
tank, use adapter tting to connect to 38 mm tank
inlet tting, if necessary.
If installing new hose from toilet to tank, use 38 mm
ID Dometic OdorSafe Plus hose. Use adapter tting
between toilet and hose, if necessary.
Use 90° elbow ttings to make bends when radius is
less than 210 mm.
A second inlet tting is provided with the Dometic
holding tank if a separate inlet tting is preferred and
only one outlet tting is required.
Item Description
1First marine toilet
(25, 38, or 40 mm discharge)
2Second marine toilet
(25, 38, or 40 mm discharge)
3Wye or Tee tting (must be
installed in direction of ow)
4Hose from toilets to holding
tank
5 Holding tank
Marine Toilet to Holding Tank
(fig. 7 , page 5)
7
13
Hose Installation
Dometic Holding Tanks
Vent tting on Dometic holding tank will accom-
modate 16 mm ID vent hose.
Install a Dometic vent lter in the vent line to
absorb malodorous gases, letting only freshened
air out of the vent.
Item Description
1 Vent hose
2 Vent lter
3 Holding tank
Note
Vent line must not have any low runs that
can create a liquid trap.
Vent Hose (fig. 9 , page 5)
9
Do not restrict the ability to pull the hose or pipe (g. 10 A, page 6).
Avoid binding corners and sharp bends ( g. 10 B, page 6).
Do not use wire ties to secure hose or pipe. Support exible hose every 0.3 m (12 inches) and
support rigid pipe every 1.5 m (5 feet).
Where possible use a support trough under the hose or pipe (g. 10 C, page 6).
Bulkhead Penetrations (fig. 11 , page 6)
Check each side of a bulkhead to ensure that there will be no cutting into:
fuel or water tanks
wiring or pipes
reinforcement stringers (4) that support the hull
When creating new holes, avoid tabs (1) and stringers (4) that hold bulkheads or partitions in place.
Provide additional reinforcement so that structural integrity is not compromised.
avoid (2)
possible (3)
Hose and Heat Sources
The operating temperature of exible hose prohibits exposure to sources of high or direct heat, such
as light bulbs or engine manifolds. If any part of the hose system must be run close to a heat source,
use rigid pipe instead of hose.
When connecting exible hose to plastic ttings (g. 12 , page 7), use special hose lubricant which is
supplied with the Dometic holding tank. Apply lubricant around end of tting and inside end of hose
that connects to tting. The Dometic lubricant makes connections easier. Do not use any other
lubricant, sealant or adhesive.
Hose Clamps (fig. 13 , page 7)
Each hose connection should be secured with two hose clamps to prevent possibility of leaks.
Position the clamp screws 180° apart from each other and tighten the clamp. Do not over-tighten
clamps or they may cut into the hose. If over-tightening is the only way to stop a leak, the hose-
to-tting connection is not sized correctly, and an adapter or different size tting is required.
6.3 Recommended hose installation methods
6.4 Connecting hose to plastic fittings
10
12
10
10
11
13
14
Dometic Holding TanksHose Installation
7 Cleaning and Winterizing
8 Specifications
A small amount of water remains in holding tanks at all times, so it is good practice to rinse a holding
tank completely after contents have been discharged.
1. After initial pump-out, add holding tank deodorant or cleaner to toilet bowl, and ush with water.
2. Continue ushing and pumping out tank until holding tank discharge is clear.
Materials
Holding tank: polyethylene; 6.3 mm nominal wall thickness. Natural color.
Fittings: polyvinyl chloride, ABS. White color.
Sealing grommets: cross-linked EPDM rubber/polypropylene. White color.
Dometic DHT-L series holding tanks are pressure-tested to 30 kPa (0.3 bar, 4 PSI).
Use only propylene glycol freshwater antifreeze to winterize the holding tank. Make sure the
antifreeze does not contain alcohol.
1. Pump out the holding tank.
2. Thoroughly ush system with fresh water before adding propylene glycol freshwater antifreeze
to the holding tank.
7.1 Cleaning
7.2 Winterizing
Model Capacity
L / US gal.
Empty Weight
Kg / lb.
Full Weight
Kg / lb.
Dimensions
mm / in.
DHT42L 42 / 11 5.4 / 12 47.9 / 105.5 460 x 350 x 348 / 18.1 x 13.8 x 13.7
DHT61L 61 / 16 7.7 / 17 69.4 / 153 660 x 350 x 348 / 26.0 x 13.8 x 13.7
DHT88L 88 / 23 10.2 / 22.5 98.9 / 218 800 x 400 x 388 / 31.5 x 15.7 x 15.3
DHT110L 110 / 29 14 / 30.9 125.9 / 277.4 1200 x 350 x 348 / 47.2 x 13.8 x 13.7
DHT137L 137 / 36 14.5 / 32 153.3 / 338 1200 x 400 x 388 / 47.2 x 15.7 x 15.3
Note
If a clamp screw is slightly magnetic, it may be either a lower grade of stainless steel or
nickel plated.
Avoid clamps with nickel-plated screws that are susceptible to corrosion. Use 100 percent stainless
steel clamps.
15
Europe:
Warranty and Customer Service
Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions
applicable for the country concerned. For warranty or other service, please contact our Dometic/
Waeco Service department listed elsewhere in this manual. Any damage due to improper use is not
covered by the warranty.
The warranty does not cover any modications to the product or the use of non-original Dometic parts;
the warranty does not apply if the installation and operating instructions are not adhered to and no
liability shall be entertained.
Product Liability
Product liability of Dometic Group and its subsidiary companies does not include damages which
may arise from: faulty operation; improper alterations or intervention in the equipment; adverse
effects from the environment which may impact the equipment itself or the direct vicinity of the
equipment or persons in the area.
To obtain warranty service, rst contact your local dealer from whom you purchased this product or go
to http://www.dometic.com to locate a dealer near you.
North America and Rest of the World:
Manufacturer’s Limited Warranty
Dometic Corporation, Sanitation Division warrants to the original purchaser only that this product, if used
for personal, family or household purposes, is free from defects in material and workmanship for a period
of one year from the date of purchase.
If this Dometic product is placed in commercial or business use, it will be warranted to the original
purchaser only to be free of defects in material and workmanship for a period of ninety (90) days
from the date of purchase.
Dometic reserves the right to replace or repair any part of this product that proves, upon inspection
by Dometic, to be defective in material or workmanship. All labor and transportation costs or charges
incidental to warranty service are to be borne by the purchaser-user.
EXCLUSIONS
IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES,
FOR DAMAGES RESULTING FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED BY
NEGLECT, ABUSE, ALTERATION OR USE OF UNAUTHORIZED COMPONENTS. ALL IMPLIED WAR-
RANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF ONE YEAR FROM DATE OF PURCHASE.
(continued on next page)
9 Warranty and Product Liability
Dometic Holding Tanks Warranty and Product Liability
16
Dometic Holding TanksWarranty and Product Liability
IMPLIED WARRANTIES
No person is authorized to change, add to, or create any warranty or obligation other than that set forth
herein. Implied warranties, including those of merchantability and tness for a particular purpose, are
limited to one (1) year from the date of purchase for products used for personal, family or household
purposes, and ninety (90) days from the date of purchase for products placed in commercial or business
use.
OTHER RIGHTS
Some states do not allow limitations on the duration of an implied warranty and some states do not
allow exclusions or limitations regarding incidental or consequential damages; so, the above limita-
tions may not apply to you. This warranty gives you specic legal rights, and you may have other rights
which vary from state to state.
To obtain warranty service, rst contact your local dealer from whom you purchased this product or go
to http://www.dometic.com to locate a dealer near you.
17
Dometic Schmutzwassertanks Hinweise zur Benutzung der Einbauanleitung
DE
Inhalt
1 Hinweise zur Benutzung der Einbauanleitung.....................................17
2 Grundlegende Sicherheitshinweise.............................................17
3 Vorgesehene Verwendung ....................................................18
4 Komponenten und Funktionen ............................................ 18 - 19
5 Tankeinbau ........................................................... 19 - 20
6 Schlauchinstallation..................................................... 20 - 23
7 Reinigen und winterfest machen...............................................23
8 Spezikationen ........................................................ 23 - 24
9 Garantie und Produkthaftung .................................................24
1 Hinweise zur Benutzung der Einbauanleitung
Hinweis
Ergänzende Informationen zur Bedienung des Gerätes.
Abb. 1, Seite 3 : Bezeichnet ein Element in einer Illustration. In diesem Beispiel
Element 1 in Abbildung 2 auf Seite 3.
2
Achtung!
Sicherheitshinweis: Nichtbeachtung kann zu Materialschäden führen und die Funktion des
Gerätes beeinträchtigen.
Achtung!
Bevor Sie an einem vorhandenen oder neu installierten Bauteil einer Sanitäranlage arbeiten,
vergewissern Sie sich, dass die elektrische Stromversorgung des Systems ausgeschaltet ist und
sich alle Seeventile in der Position geschlossen oder aus benden. Andernfalls kann es zu einer
Überutung kommen. Es besteht die Gefahr von Unfällen mit Todesfolge oder Vermögensschäden.
2 Grundlegende Sicherheitshinweise
Der Hersteller übernimmt keine Haftung für Schäden aufgrund von
Montage- oder Anschlussfehlern
Schäden am Gerät durch mechanische Einwirkung
Modikationen am Gerät ohne ausdrückliche Genehmigung des Herstellers
Verwendung für andere als die in der Anleitung beschriebenen Zwecke.
Wenn Sie für den Einbau des Systems elektrische Geräte verwenden, beachten Sie die folgenden
Sicherheitshinweise. Diese Hinweise dienen dem Schutz vo:
Elektrischem Schlag
• Brandgefahr
• Verletzung
18
Dometic SchmutzwassertanksVorgesehene Verwendung
Hinweis
Alle Leitungen, über die Grauwasser in den Schmutzwassertank eingeleitet wird, müssen
mit Geruchsverschluss ausgerüstet werden, damit der Aufenthaltsbereich geruchfrei bleibt.
Achtung!
Der Bootsbetreiber muss mit den örtlichen Bestimmungen zur Abwassereinleitung vertraut sein.
3 Vorgesehene Verwendung
Dometic Schmutzwassertank-Systeme sind hochwertige, langlebige Anlagen zum Auffangen
von Toilettenabwässern auf Booten. Diese Abwässer können anschließend an den zugelassenen
Entsorgungseinrichtungen (bzw. in Gewässern, in denen die unbedenkliche Entsorgung von
Abwässern gestattet ist) efzient entsorgt werden. Die Systeme verhindern die Verseuchung
sensibler Gewässerbereiche z. B. an Marinas, strandnahen Abschnitten oder Muschelbänken
Dometic Schmutzwassertanks sind auch für Grauwasser (Wasser aus Duschen, Becken,
Waschmaschinen, usw.) geeignet, sofern ausschließlich Grauwasser in den Tank eingeleitet wird.
4 Komponenten und Funktionen
Teile in Abb. ,
Seite 3 Beschreibung
1 Schlauchanschluss (38 mm / 1,5 Zoll ID) zum Deckstutzen oder Seeventil
2 Schlauchanschluss (38 mm / 1,5 Zoll ID) zum Deckstutzen oder Seeventil
3
Schauöffnung oder Ort für optionalen Füllstandsmesser
4 Anschluss für Entlüftungsschlauch (16 mm / 0,625 Zoll ID)
5 Druckausgleichsventil
6 Anschluss für Einlassschlauch von der Toilette (38 mm / 1,5 Zoll ID)
7 integrierte Montagefüße (an 4 Stellen)
2
Lecksichere Konstruktion. Auf der Tankoberseite sind Dometic Armaturen angeschlossen. Diese
verhindern, dass durch fehlerhaftes Anschließen unterhalb des Tankfüllstands Lecks auftreten.
Geruchsfreier, langlebiger Betrieb. Die Tanks sind aus PE-LLD (lineares Polyethylen niederer Dichte)
gefertigt. Dieser Werkstoff ist wegen seiner Korrosionsfestigkeit und Geruchsbeständigkeit das beste
Material für Schmutzwassertanks. Die Tanks sind langlebiger als ein handelsüblicher Bootsrumpf.
Implosionsschutz. Die Kombination aus hochbelastbarem Tank und Vakuum-Druckausgleichsventil
verhindert Schäden durch landseitige Pumpen, die mit starkem Unterdruck arbeiten
3.1 Vorteile von Dometic Schmutzwassertanks
19
Dometic Schmutzwassertanks Komponenten und Funktionen
Hinweis
Nur einer der Auslassstutzen (1 oder 2) kann bei Bedarf in einen Einlassstutzen umge-
wandelt werden. Ein Auslass muss an der ursprünglichen Stelle am Tank verbleiben. Der
Einlassstutzen an der gegenüber liegenden Seite des Tanks (6) sollte nicht in einen
Auslassstutzen umgebaut werden.
Vorinstallierter Einlass und zwei Auslässe für landseitigen Anschluss und Seeventilanschluss.
Einlass- und Auslassstutzen sind drehbar, um den Schlauchanschluss aus nahezu beliebiger
Richtung zu ermöglichen (Abb. 3 D, Seite 3).
Die Auslassrohre haben ein spezielles verstopfungssicheres Design.
Das Druckausgleichsventil schützt den Tank vor der Zerstörung durch Überdruck.
Extra-Armaturen ermöglichen den Umbau des Tanks für verschiedene Einlass-/Auslass-Kongurationen
– ein Einlass, zwei Auslässe (Abb. 3 A, Seite 3)
– ein Einlass, ein Auslass auf derselben Tankseite (Abb. 3 B, Seite 3)
– ein Einlass, ein Auslass auf verschiedenen Tankseiten (Abb. 3 C, Seite 3)
Erfüllt die Anforderungen von ISO 8099.
4.1 Eigenschaften
5 Tankeinbau
Wählen Sie eine Stelläche in geeigneter Lage, die den gesamten Tank tragen kann. Wenn eine
Einbauäche hergestellt werden muss, verwenden Sie seewasserfestes Sperrholz von mindestens
13 mm Dicke. Wenn der Tank mit Spanngurten gesichert wird, verstärken Sie die Kanten der
Einbauäche (Abb. 4 B, Seite 4).
Einbau an den integrierten Montagefüßen (Abb. 4 A, Seite 4)
Befestigen Sie den Tank an den vier Montagefüßen auf der Einbauäche. Verwenden Sie dazu Schrauben
(Nr. 12) mit mindestens 6 mm Durchmesser und Unterlegscheiben mit höchstens 19 mm Durchmesser.
5.1 Wählen Sie einen Aufstellungsort für den Schmutzwassertank aus.
5.2 Vorbereiten einer Einbaufläche
5.3 Aufstellen des Tanks auf der Einbaufläche
Achtung!
Der Schmutzwassertank sollte keinen Temperaturen über 45 °C (120 °F) ausgesetzt werden.
Stellen Sie den Tank nicht in der Nähe von Wärmequellen, wie Krümmern der Maschine,
Wasserboilern, Generatoren, usw. auf.
Der Schmutzwassertank sollte so tief wie möglich im Schiffsrumpf positioniert werden. Die meisten
Verbindungsschläuche und Rohrleitungen sollten ein Gefälle zum Tank haben, um eine Entwässerung
durch Schwerkraft zuzulassen und einer möglichen Geruchsentwicklung durch den Schlauch vorzubeu-
gen. Der an die Über-Bord-Auslasspumpe angeschlossene Schlauch sollte vom Tank wegführen.
Lassen Sie zusätzlich zu den Maßen des Tanks (Abb. 1 , Seite 2) über dem Tank 16 cm (ca. 6
Zoll) frei, um die Anschlussarbeiten zu erleichtern.
ZUGANG FÜR WARTUNG – Da Schmutzwassertanks von Dometic im Regelbetrieb unter
Umständen geringfügige Wartungsarbeiten erfordern, muss der Tank so installiert werden, dass
die Inspektionsöffnung gut zugänglich ist.
3
3
1
4
4
3
3
20
Entlüftungsschlauchgrößen
für Sanitärsysteme
(Abb. , Seite 4)
Tankeinbau Dometic Schmutzwassertanks
6 Schlauchinstallation
Dometic Schmutzwassertanks sind mit Schlauchanschlusss-
tutzen von 38 mm (1,5 Zoll) und 16 mm (0,625 Zoll) Innen-
durchmesser vormontiert. Wenn in Ihrem Sanitärsystem andere
Schlauchgrößen verwendet werden, passen Sie die Dometic
Stutzen mit entsprechenden Adaptern auf die vorhandene
Schlauchgröße an, oder bauen Sie einen neuen Schlauch ein,
der auf die Dometic Tankstutzen passt.
Wenn Sie einen neuen Schlauch installieren, bietet der Dometic
OdorSafe® Plus-Sanitärschlauch für Toiletten- und Schmutz-
wassertank-Auslassleitungen den besten Schutz vor Geruchs-
durchdringung. Dieser Schlauch ist nur mit 38 mm (1,5 Zoll)
Innendurchmesser verfügbar. Dometic MaxFlex Schlauch ist in
allen Größen erhältlich, die unter „Entlüftungsschlauchgrößen für
Sanitärsysteme“ (rechts) angegeben sind, und bietet hochwerti-
gen Schutz vor Geruchsdurchdringung.
6.1 Schlauchauswahl
6.2 Schlauchaufbau
Schlüssel (Abb. , Seite 4)
Feld Beschreibung
1Sanitärschlauch
(38 mm / 1,5 Zoll ID)
2Sanitärschlauch
(25 mm / 1 Zoll ID)
3Entlüftungsschlauch
(19 mm / 0,75 Zoll ID)
4Entlüftungsschlauch
(16 mm / 0,625 Zoll ID)
Ref. Beschreibung
A Komplizierter Installationsaufbau
B Vereinfachter Installationsaufbau
1 Problemschlauch
2 Schmutzwassertank
6
Hinweis
Die Befestigungsmittel (Schrauben, Unterlegscheiben usw.) und Spanngurte gehören nicht
zum Lieferumfang des Dometic Schmutzwassertanks.
Ref. Beschreibung
3 Fäkalienpumpe
4 Seeventil (Über-Bord-Auslass)
5 Y-Ventil
6 Auslasspumpe
Achtung!
Stellen Sie den Tank nicht auf herausstehende Objekte (z. B. auf Schraubenköpfe), da er
sonst beschädigt werden kann. Achten Sie darauf, dass der Schmutzwassertank nicht den
freien Fluss des Bilgewassers behindert.
Einbau mit Spanngurten (Abb. B, Seite 4)
Befestigen Sie den Tank auf beiden Seiten mit Spanngurten (maximal 31 mm / 1,25 Zoll breit) auf
der Einbauäche. Führen Sie die Spanngurte über die Gurtführungen, die beidseitig auf der Tanko-
beräche eingelassen sind.
4
5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Dometic DHT-L Series Holding Tanks Guida d'installazione

Tipo
Guida d'installazione