CAME RSLV001 - RSLV001AC Guida d'installazione

Tipo
Guida d'installazione
FA01585M4A
IT Italiano
EN English
FR Français
RU Русский
CAME S.p.A.
Via Martiri della
Libertà, 15
31030 Dosson di
Casier
Treviso - Italy
10
2
A
B
CONNECT
RSLV001
50mA24V
869.5MHz 14dBm
RED - O1
BLUE - O2
YELL - I1
WHITE
- I2
BLK - GND
2 3 4
1A 30V
MATR
550126
O1
O2
l1
l2
GND
10 2 A B
A
56
53,5
42,5
46
18
46
2
1C
FA01585M4A - 04/2021
806SA-0040
806SA-0190
2 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
CONNECT
RSLV001
50mA24V
869.5MHz 14dBm
RED - O1
BLUE - O2
YELL - I1
WHITE
- I2
BLK - GND
2 3 4
1A 30V
10
2
A
B
1 2 3 4 1
2
3
4
A B GND
RSE
CONTROL BOARD
MATR
550126
10 11 2 CX CY
D
3 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
R
S
24
V
86
9
RED - O
1
BLUE - O
2
YELL - I1
WHITE
- I2
BLK - G
N
10
2
A
B
A B GND
RSE
150 Ohm
150 Ohm
RSE
1 2 3 4 1 3 4
3
4
1 3 41 2 3 4
RSE
2 21 2 3 4
CONTROL BOARD CONTROL BOARD CONTROL BOARD
2
1
A B GNDA B GND
乧䢢䢭䢢乧䢢䢭䢢乧䢢= 1000m (max)
10 11 2 CX CY 10 11 2 CX CY 10 11 2 CX CY
E
4 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
CONNECT
RSLV001
50mA24V
869.5MHz 14dBm
RED - O1
BLUE - O2
YELL - I1
WHITE
- I2
BLK - GND
2 3 4
1A 30V
10
2
A
B
CONTROL BOARD CONTROL BOARD
MATR
550126
27
CY
27
CY
F
5 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
NON CRP
(x2 max)
CRP
AUTOMATION
(x3 max)
CRP
AUTOMATION
(x3 max)
NON CRP
AUTOMATION
(x2 max)
AUTOMATION
RETH001
MASTER
SLAVE
RSLV001/RSLV001AC
(x5 max)
SLAVE
MASTER
RGSM001
RGSM001AC
GPRS
RSLV001/RSLV001AC
G
6 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
ITALIANO
Avvertenze Generali
Importanti istruzioni per la sicurezza delle persone: LEGGERE ATTENTAMENTE!
L’installazione, la programmazione, la messa in servizio e la manutenzione devono essere e ettuate da personale qualifi cato ed esperto
e nel pieno rispetto delle normative vigenti. • Indossare indumenti e calzature antistatiche nel caso di intervento sulla scheda elettronica.
• Prima di e ettuare qualunque operazione di pulizia o di manutenzione, togliere l’alimentazione al dispositivo. • Il prodotto deve essere
destinato solo all’uso per il quale è stato espressamente studiato e ogni altro uso è da considerarsi pericoloso. • Came S.p.A. non è
responsabile per eventuali danni causati da usi impropri, erronei ed irragionevoli. • Conservare queste avvertenze.
Il prodotto è conforme alle direttive applicabili, vigenti al momento della fabbricazione.
Dismissione e smaltimento
Non disperdere nell’ambiente l’imballaggio e il dispositivo alla fi ne del ciclo di vita, ma smaltirli seguendo le norme vigenti nel paese di
utilizzo del prodotto. I componenti riciclabili riportano simbolo e sigla del materiale.
I DATI E LE INFORMAZIONI INDICATE IN QUESTO MANUALE SONO DA RITENERSI SUSCETTIBILI DI MODIFICA IN QUALSIASI MOMENTO E
SENZA OBBLIGO DI PREAVVISO.
LE MISURE, SE NON DIVERSAMENTE INDICATO, SONO IN MILLIMETRI.
7 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Descrizione
RSLV001 - Modulo Slave per automazioni (modulo 002RSE compreso).
RSLV001AC - Modulo Slave per accessi (modulo 002RSE compreso).
Il dispositivo funziona solo se abbinato ad un modulo MASTER RGSM001/RGSM001AC o RETH001.
A Descrizione delle parti
1 Pulsante P1 per il reset o riavvio del modulo
Tenere premuto 10 secondi per riportare il modulo alle
condizioni di fabbrica (reset).
Tenere premuto per più di 3 secondi e poi rilasciare per
riavviare il modulo.
2 PIN B interfaccia 485
3 PIN A interfaccia 485
4 GND CRP / - Alimentazione
5 + Alimentazione
6 (rosso) Relè 1, 30V DC - 1A (max) N.O.
7 (blu) Relè 2, 30V DC - 1A (max) N.O.
8 (giallo) Ingresso 1 (24V DC max)
9 (bianco) Ingresso 2 (24V DC max)
10 (nero) Comune Ingressi
11 LED POWER (verde)
12 LED OUT2 (rosso)
13 LED OUT1 (rosso)
14 Scheda gestione funzioni (RSE)
15 LED CONNECT (rosso)
Il dispositivo è dotato di una antenna fi lare esterna che non deve essere rimossa.
8 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
LED di segnalazione
Acceso sso Spento Lampeggia
ogni 3 secondi
1 lampeggio
al secondo
3 lampeggi
al secondo
5 lampeggi
al secondo
LED POWER
(verde)
Alimentato e
connesso al
modulo MASTER
Modulo non
alimentato
Pulsante P1
premuto
Modulo non
confi gurato
(default)
LED OUT1
(rosso) Relè 1 chiuso Relè 1 chiuso
LED OUT2
(rosso) Relè 2 chiuso Relè 2 chiuso
LED CONNECT
(rosso)
Non connesso al
modulo MASTER
/ modulo
MASTER non
connesso a
CAMEConnect
Connesso al
modulo MASTER
Aggiornamento
rmware da
remoto in corso
9 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Dati tecnici
MODELLI RSLV001 RSLV001AC
Alimentazione (V AC) 12 - 30
Alimentazione (V DC) 12 - 30
Assorbimento massimo (mA) 50
Temperatura d’esercizio (°C) -20 ÷ +70
Portata segnale radio 869,5 MHz in aerea libera (m) 100
Portata segnale radio 869,5 MHz (dbm) 14
Potenza segnale GSM-EGSM - 900MHz (dBm) 33
Potenza segnale GSM-EGSM - 1800MHz (dBm) 30
Materiale Composto di Policarbonato
Ingressi digitali (V DC max) 24
Uscite relè (V DC max) 1
Uscite relè (A max) 30
Lunghezza massima del cavo collegato alle uscite relè (m) 3
Lunghezza massima del cavo collegato all'uscita 485 (m) 1000
10 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Installazione
Non installare più dispositivi radio ad una distanza inferiore a 4 metri l'uno dall'altro.
Posizionare l'antenna più in alto possibile dal suolo, lontana da strutture metalliche o cemento armato.
B Fissare il modulo alle guide DIN se presenti nell'automazione.
Il modulo può essere installato anche esternamente purchè opportunamente fi ssato in un contenitore con almeno grado IP44.
Il dispositivo deve essere sempre installato lontano da superfi ci e oggetti metallici. In ogni caso la scheda elettronica non deve
essere inserita in contenitori metallici.
Collegamenti elettrici
Prima di ogni operazione di collegamento, è OBBLIGATORIO SCOLLEGARE L'ALIMENTAZIONE.
Nel caso il dispositivo non sia alimentato da quadro Came, assicurarsi che l'alimentazione fornita sia provvista di
alimentazione in corrente non superiore a 1A.
Nel caso di collegamento a quadro comando CAME dotato di CRP mediante morsetto A-B-GND, alimentare il modulo solo
da morsetti 2-10 del quadro stesso.
Lunghezza dei cavi
Tratta Tipo cavo
aPVC FROF 2 x 0,5
cUTP CAT5 - AWG24
Tratta Lunghezza max. tratta
a3 m
c1000 m
11 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
C
Collegamento di una singola automazione
D
Collegamento di più automazioni
Se necessario inserire la scheda RSE e impostare un numero di periferica per ogni scheda (vedi funzione [F56 Numero
Periferica] nel manuale dell'automazione o del quadro comando).
Tutte le automazioni connesse al modulo devono avere Baud rate impostato a 38400 (vedi funzione [F63 Velocità RSE] nel
manuale dell'automazione o del quadro comando).
La tabella di compatibilità del modulo è disponibile al seguente indirizzo: http://www.cameconnect.net/came/docs/
cameconnect_compliant_devices.html
E Collegamento di automazioni non CRP
Utilizzando le uscite a relè è possibile comandare fi no ad un massimo di 2 automazioni mediante CAMEConnect.
L'associazione del modulo RSLV001/RSL001AC (SLAVE) ad un modulo RGSM001/RSGM001AC (MASTER) deve essere
eseguita dal proprio account CAMEConnect utilizzando il keycode stampato sull'etichetta. Seguire le indicazioni dei manuali
CAMEConnect Automazioni (http://www.cameconnect.net/came/pages/documentazione_elenco.html).
Prima di essere associato ad un nuovo modulo RGSM001/RGSM001AC (MASTER), il modulo RSLV001/RSLV001AC (SLAVE)
deve essere riportato alle condizioni di fabbrica.
12 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
ENGLISH
General Precautions
Important safety instructions. PLEASE READ CAREFULLY.
Installation, programming, commissioning and maintenance must only be carried out by qualifi ed, expert sta and in full compliance
with the applicable law. • Wear anti-static clothing and footwear if performing work on the circuit board. • Before carrying out any
cleaning or maintenance, disconnect the device from the power supply. • Only use this product for its intended purpose. Any other use
is hazardous. • Came S.p.A. is not liable for any damage caused by improper, erroneous or unreasonable use. • Keep this information.
This product complies with the applicable standards in force at the time of manufacturing.
Dismantling and disposal
Dispose of the packaging and the device responsibly at the end of its life cycle, in compliance with the laws in force in the country
where the product is used. The recyclable components are marked with a symbol and the material ID marker.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE.
THE MEASUREMENTS, UNLESS OTHERWISE STATED, ARE IN MILLIMETRES.
13 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Description
RSLV001 - Slave module for operators (002RSE module included).
RSLV001AC - Slave module for access (002RSE module included).
The device only works if paired with an RGSM001/RGSM001AC or RETH001 MASTER module.
A Description of parts
1 P1 button for resetting or rebooting the module
Press and hold for 10 seconds to reset the module to its
factory settings.
Press and hold for more than 3 seconds and then release
to reboot the module.
2 Interface 485 PIN B
3 Interface 485 PIN A
4 GND CRP / - Power supply
5 + Power supply
6 (rosso) Relay 1, 30V DC - 1A (max) N.O.
7 (blu) Relay 2, 30V DC - 1A (max) N.O.
8 (giallo) Input 1 (24V DC max)
9 (bianco) Input 2 (24V DC max)
10 (nero) Common inputs
11 POWER LED (green)
12 OUT2 LED (red)
13 OUT1 LED (red)
14 Function control board (RSE)
15 CONNECT LED (red)
This device is fi tted with an external wire antenna which must not be removed.
14 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Alert LED
On O Flashes
every 3 seconds
1 fl ash per
second
3 fl ashes
per second
5 fl ashes
per second
POWER LED
(green)
Powered up and
connected to the
MASTER module
Module not
powered up
P1 button
pressed
Module not
confi gured
(default)
OUT1 LED (red) Relay 1 closed Relay 1 closed
OUT2 LED (red) Relay 2 closed Relay 2 closed
CONNECT LED
(red)
Not connected
to the MASTER
module /
MASTER module
not connected to
CAMEConnect
Connected to
MASTER module
Firmware
updating
remotely...
15 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Technical data
MODELS RSLV001 RSLV001AC
Power supply (V AC) 12 - 30
Power supply (V DC) 12 - 30
Maximum absorption (mA) 50
Operating temperature (°C) -20 ÷ +70
Radio signal range 869.5 MHz in an open area (m) 100
Radio signal range 869.5 MHz (dBm) 14
GSM-EGSM signal power - 900 MHz (dBm) 33
GSM-EGSM signal power - 1800 MHz (dBm) 30
Item Polycarbonate compound
Digital inputs (V DC max) 24
Relay outputs (V DC max) 1
Relay outputs (A max) 30
Maximum length of the cable connected to the relay outputs (m) 3
Maximum length of the cable connected to the 485 output (m) 1000
16 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Installation
Do not install radio devices less than 4 meters apart.
Place the antenna as high up as possible from the ground, well away from any metal or reinforced-concrete structures.
B
Fix the module to the DIN rails, where present on the operator.
The module can also be installed outdoors, provided it is fastened inside a case with a protection rating of at least IP44.
The device must always be installed well away from metal surfaces and objects. In any case, the control board must not be
tted inside metal containers.
Electrical connections
Before making any connections, YOU MUST DISCONNECT THE MAINS POWER.
If the device is not powered by a Came panel, ensure that the power supply has current not greater than 1A.
Where the device is connected to a CAME control panel equipped with CRP via terminal A-B-GND, power the module only
from terminals 2-10 on the panel itself.
Cable length
Section Cable type
aPVC FROF 2 x 0.5
cUTP CAT5 - AWG24
Section Maximum section length
a3 m
c1000 m
17 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
C
Connecting a single operator
D
Connecting several operators
If necessary, insert the RSE card and set a peripheral number for each card (see the [F56 Peripheral Number] function in the
operator or control panel manual).
All the operators connected to the module must have their Baud rate set to 38400 (see the [F63 RSE Speed] function in the
operator or control panel manual).
The module compatibility table is available at the following address: http://www.cameconnect.net/came/docs/cameconnect_
compliant_devices.html
E Connecting non-CRP operators
Using the relay outputs you can control up to 2 operators with CAMEConnect.
The RSLV001/RSL001AC module (SLAVE) must be associated with an RGSM001/RSGM001AC module (MASTER) from
your CAMEConnect account, using the key code printed on the label. Follow the instructions in the CAMEConnect operator
manuals (http://www.cameconnect.net/came/pages/documentazione_elenco.html).
Before being associated with a new RGSM001/RGSM001AC module (MASTER), the RSLV001/RSLV001AC module (SLAVE)
must fi rst be restored to its factory settings.
18 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
FRANÇAIS
Instructions générales
Instructions importantes pour la sécurité des personnes: À LIRE ATTENTIVEMENT!
L’installation, la programmation, la mise en service et l'entretien doivent être e ectués par du personnel qualifi é et dans le plein
respect des normes en vigueur. • Porter des vêtements et des chaussures antistatiques avant d'intervenir sur la carte électronique. •
Avant toute opération de nettoyage ou d'entretien, mettre le dispositif hors tension. • Ce produit ne devra être destiné qu'à l'utilisation
pour laquelle il a été expressément conçu et toute autre utilisation est à considérer comme dangereuse. • Came S.p.A. décline
toute responsabilité en cas de dommages provoqués par des utilisations impropres, incorrectes ou déraisonnables. • Conserver ces
instructions.
Ce produit est conforme aux directives applicables, en vigueur lors de sa fabrication.
Mise au rebut et élimination
Ne pas jeter l'emballage et le dispositif dans la nature au terme du cycle de vie de ce dernier, mais les éliminer selon les normes en
vigueur dans le pays où le produit est utilisé. Le symbole et le sigle du matériau fi gurent sur les composants recyclables.
LE CONTENU DE CE MANUEL EST SUSCEPTIBLE DE SUBIR DES MODIFICATIONS À TOUT MOMENT ET SANS AUCUN PRÉAVIS.
LES DIMENSIONS SONT EXPRIMÉES EN MILLIMÈTRES, SAUF INDICATION CONTRAIRE.
19 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Description
RSLV001 - Module Slave pour automatismes (module 002RSE compris).
RSLV001AC - Module Slave pour accès (module 002RSE compris).
Ce dispositif ne fonctionne que s’il est associé à un module MASTER RGSM001/RGSM001AC ou RETH001.
A Description des parties
1 Bouton P1 pour la remise à zéro ou le rallumage du module
Enfoncé pendant 10 secondes, il permet la réinitialisation
du module aux valeurs d’usine (reset).
Appuyer pendant plus de 3 secondes puis relâcher pour
rallumer le module.
2 PIN B interface 485
3 PIN A interface 485
4 GND CRP / - Alimentation
5 + Alimentation
6 (rosso) Relais 1, 30 VDC - 1 A (max.) N.O.
7 (blu) Relais 2, 30 VDC - 1 A (max.) N.O.
8 (giallo) Entrée 1 (24 VDC max.)
9 (bianco) Entrée 2 (24 VDC max.)
10 (nero) Commun Entrées
11 LED POWER (verte)
12 LED OUT2 (rouge)
13 LED OUT1 (rouge)
14 Carte de gestion des fonctions (RSE)
15 LED CONNECT (rouge)
Ne jamais enlever l’antenne fi laire externe dont le dispositif est doté.
20 - FA01585M4A - 04/2021 - © CAME S.p.A. - -
Voyant de signalisation led
Allumé en
permanence Éteint
Clignote
toutes les 3
secondes
1
clignotement
par seconde
3
clignotements
par seconde
5
clignotements
par seconde
LED POWER
(verte)
Alimenté et
connecté au
module MASTER
Module hors
tension
Bouton P1
enfoncé
Module non
confi guré (par
défaut)
LED OUT1
(rouge) Relais 1 fermé Relais 1 fermé
LED OUT2
(rouge) Relais 2 fermé Relais 2 fermé
LED CONNECT
(rouge)
Non connecté
au module
MASTER /
module MASTER
non connecté à
CAMEConnect
Connecté au
module MASTER
Mise à jour du
rmware en
cours à distance
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

CAME RSLV001 - RSLV001AC Guida d'installazione

Tipo
Guida d'installazione