Peerless DS-LEDL27-6X6 Guida d'installazione

Tipo
Guida d'installazione

Questo manuale è adatto anche per

12020-03-17 #:146-9043-1
ENG
DS-LEDL27 Series
*Actual conguration may vary
22020-03-17 #:146-9043-1
Symbols
ENG
WARNING
ENG
Do not overtighten screws.
ENG
Tools Needed for Assembly.
ENG
5/32"
(4mm)
ENG - This product is designed to be installed on plywood walls. Hardware is included for plywood installation.
Before installing make sure the supporting surface will support the combined load of the equipment and
hardware. Screws must be tightly secured. Do not overtighten screws or damage can occur and product may fail.
Never exceed the Maximum Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift
and position equipment. This product is intended for indoor use only. Use of this product outdoors could lead to

call customer care at 1-800-865-2112.
WARNING
3/8"
(10mm)
3/8"
(10mm)
#
Skip to step.
ENG
2.5mm
Wear anti-static gloves.
ENG
1
2
ENG To properly tighten screws: Tighten until screw
head makes contact, then tighten another 1/2
turn. Do not overtighten screws.
4
+1/2
3
32020-03-17 #:146-9043-1
This page intentionally left blank.
ENG
42020-03-17 #:146-9043-1
H
IJL M5 x 5mm
set screw
#14 x 1.75"
wood screw M5 x 8mmM5 x 12mm
A B C
left column right column inside column
Parts List
Description
Aleft column
Bright column
Cinside column
Dvertical spacer
Ehorizontal spacer
Fextrusion connector
G3mm allen wrench two-tip T-handle
HM5 x 5mm set screw
I#14 x 1.75" wood screw
JM5 x 8mm
Kwall plate shim
LM5 x 12mm
Mtop horizontal asy
Nbottom horizontal asy
Otop left horizontal asy
Ptop right horizontal asy
Qbottom left horizontal asy
Rbottom right horizontal asy
Parts (Before beginning, make sure you have all parts shown below).
ENG
M
N
top horizontal asy
bottom horizontal asy
K
wall plate
shim
E
horizontal
spacer
F
extrusion
connector
D
vertical spacer
G
3mm allen wrench
two-tip T-handle
52020-03-17 #:146-9043-1
O P
Q R
top left
horizontal asy
top right
horizontal asy
bottom left
horizontal asy
bottom right
horizontal asy
62020-03-17 #:146-9043-1
1-1
Optional: If connecting two top horizontal extrusions,

ENG
Remove and save hardware.
ENG
M,O
M,P
1-2
Use extrusion connectors to connect top horizontal
extrusions.
ENG
F (4) H (8)
G
2.5mm
M,P
M,O
72020-03-17 #:146-9043-1
2-1
Optional: If connecting two bottom horizontal

ENG
Remove and save hardware.
ENG
N,R
N,Q
1-3
Replace one hook-on bracket in between connected
extrusions.
ENG
Use saved hardware.
ENG
G
G
M,P
M,O
82020-03-17 #:146-9043-1
N,R
N,R
N,Q
N,Q
2-2
Use extrusion connectors to connect bottom
horizontal extrusions.
ENG
H (6)
F (3)
2-3
Replace one hook-on bracket in between connected
extrusions.
ENG
Use saved hardware.
ENG
G
2.5mm
92020-03-17 #:146-9043-1
3-1
Use a laser level to keep mounting holes
level.
ENG
3
ENG - When installing Peerless wall mounts on a wood stud wall covered with plywood, verify that the wood
studs are a minimum of 2" x 4" nominal size and plywood is a minimum Grade BC, 1/2" (13 mm) thick. Plywood
may be covered by gypsum board (drywall) up to 5/8" thick.
WARNING
10 2020-03-17 #:146-9043-1
3-2
Level top horizontal extrusion and mark
mounting holes on plywood (must be
minimum Grade BC, 1/2" (13mm) thick.)
ENG
N,P
display tile
7/8" (22mm) minimum
for mounting clearance
x"
Video Wall
Rows Dimension x"
12.75"
22.77"
32.78"
42.43"
52.32"
62.35"
72.23"
82.13"
11 2020-03-17 #:146-9043-1
3-3
Drill mounting holes into supporting surface
(1.75" (44mm) minimum depth required).
ENG
5/32"
(4mm)
1.75"
(44mm)
5/32"
(4mm)
3-4
Level extrusion. Install using wood screws
provided.
ENG
3/8"
(10mm)
Maximum 80 in. • lb (9 N.M.).
ENG
I (5)
N,P
12 2020-03-17 #:146-9043-1
3-5

horizontal extrusion.
ENG
3/8"
(10mm)

ENG
D
I
M,O
D (2)
I (2)
13 2020-03-17 #:146-9043-1
3-6
Use third vertical spacer to align bottom

then mark mounting holes on plywood (must be
minimum Grade BC, 1/2" (13mm) thick.)
ENG
58.68"
(149cm)
D

ENG
D
N,Q
N,R
14 2020-03-17 #:146-9043-1
3-8
Use third vertical spacer to align bottom

spacer, then install using wood screws
provided.
ENG
3/8"
(10mm)
Maximum 80 in. • lb (9 N.M.).
ENG
3-7
Drill mounting holes into supporting surface
(1.75" (44mm) minimum depth required).
ENG
5/32"
(4mm)
1.75"
(44mm)
5/32"
(4mm)
I (5)
N,R
15 2020-03-17 #:146-9043-1
3-9
Remove vertical spacer.
ENG
3/8"
(10mm)
D (2)
I (2)
16 2020-03-17 #:146-9043-1
4-1
Hook on and secure outer vertical columns.
"L" and "R" markings designate left and right
column.
ENG
A
B
J (8)
Tighten hardware.
ENG
G
17 2020-03-17 #:146-9043-1
4-2
Hook on and secure all inside vertical
columns.
ENG
C (4)
Tighten hardware.
ENG
J (16)
G
18 2020-03-17 #:146-9043-1
5-1
Loosen hardware on vertical columns.
ENG G
19 2020-03-17 #:146-9043-1
5-2
Tighten.
ENG
Tighten.
ENG
Plumb and level outer columns, then tighten
hardware. Tighten hardware on four corner wall
plates.
ENG G
20 2020-03-17 #:146-9043-1
Tighten.
ENG
Loosen.
ENG
Optional leveling for bowed walls
ENG
Insert.
ENG
K
5-3
Tie a string between top slots on outer
columns in order to level the depth of each
vertical column.
ENG
Loosen, adjust, tighten.
ENG
G
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Peerless DS-LEDL27-6X6 Guida d'installazione

Tipo
Guida d'installazione
Questo manuale è adatto anche per