Auerswald SG-200 Istruzioni per l'uso

Tipo
Istruzioni per l'uso

Questo manuale è adatto anche per

884379 V02 11/2018
SG-100 / SG-200
Überspannungsschutzmodule
Overvoltage protection modules
Betriebsanleitung Deutsch
Instructions English
Manual de instrucciones Español
Οδηγίες λειτουργίας Ελληνικά
Notice d’utilisation Français
Istruzioni per l’uso Italiano
Gebruikshandleiding Nederlands
Instrukcja obsługi Polski
Lieferumfang (de) / Scope of Delivery (en) / Volumen de
suministro (es) / Εξοπλισμός παράδοσης (el) / Contenu de la
livraison (fr) / Dotazione (it) / Leveringsomvang (nl) / Zakres
dostawy (pl)
Kontaktdaten (de) / Contact Data (en) / Datos de contacto (es) /
Στοιχεία επικοινωνίας (el) / Coordonnées (fr) / Dati di contatto
(it) / Contactgegevens (nl) / Dane połączeń (pl)
Hersteller/Manufacturer: Auerswald GmbH & Co. KG, Hordorfer Str.
36, 38162 Cremlingen, Germany
DACHL
www.auerswald.de
BEFGBGRINLPL
www.fontevo.com
Copyright
Auerswald GmbH & Co. KG, 38162 Cremlingen, Germany, 2018
Montage (de) / Assembly (en) / Montaje (es) / Συναρμολόγηση
(el) / Montage (fr) / Montaggio (it) / Montage (nl) / Montaż (pl)
Installation (de) / Installation (en) / Instalación (es) /
Εγκατάσταση (el) / Installation (fr) / Installazione (it) / Installatie
(nl) / Instalacja (pl)
Anwendungsbeispiel eines SG-200 für den Mittelschutz.
Weitere Anschaltpläne des SG-100 bzw. SG-200 finden Sie
auf unserer Internetseite.
*Router
** Potentialausgleich
de
*
*
**
**
***
2x
2x
*
SG-200
**
Example application, using an SG-200 for medium protection.
Further wiring diagrams of the SG-100 or SG-200 can be
found on our website.
*router
** ground
en
Ejemplo de aplicación de un SG-200 para protección media.
Encontrará más esquemas de conexión para el SG-100 y el
SG-200 en nuestra página web.
*Router
** Conexión equipotencial
es
Παράδειγμα χρήσης ενός SG-200 για τη μεσαία προστασία.
Για επιπλέον διαγράμματα κυκλώματος του SG-100 και του
SG-200, βλέπε τα διαγράμματα κυκλώματος στον ιστότοπό
μας.
*Δρομολογητής
** Γείωση
el
Exemple d’utilisation d’un SG-200 pour une protection
moyenne.
Pour d’autres schémas de câblage du SG-100 ou du SG-200,
voir les schémas de câblage sur notre site Internet.
*Routeur
** Liaison équipotentielle
fr
Esempio di utilizzo di un SG-200 per protezione media.
Per ulteriori schemi di collegamento dell’SG-100 o dell’SG-
200 si vedano gli schemi di collegamento sulla nostra pagina
web.
*Router
** Barra equipotenziale
it
Toepassingsvoorbeeld van een SG-200 voor
middelbeveiliging.
Zie voor meer inschakelschema's van de SG-100 of SG-200
onze website.
*Router
** Potentiaalvereffening
nl
Przykład zastosowania urządzenia SG-200 jako
zabezpieczenia o średniej czułości.
Inne schematy połączeń urządzenia SG-100 lub SG-200
można znaleźć na naszej stronie internetowej.
*Router
** Wyrównanie potencjałów
pl
* Eingang: ungeschützte Leitung (RJ45 o. Drahtklemme)
** Ausgang: geschützte Leitung (RJ45 o. Drahtklemme)
*** Potentialausgleich
de
* input: unprotected line (RJ45 or wire terminal)
** output: protected line (RJ45 or wire terminal)
*** ground
en
* Entrada: línea no protegida (RJ45 o terminal de borne)
** Salida: línea protegida (RJ45 o terminal de borne)
*** Conexión equipotencial
es
*Είσοδος: καλώδιο χωρίς προστασία (RJ45 χωρίς
σφιγκτήρα σύρματος)
** Έξοδος: καλώδιο με προστασία (RJ45 χωρίς σφιγκτήρα
σύρματος)
*** Γείωση
el
* Entrée : câble non protégé (RJ45 ou borne de fil)
** Sortie : câble protégé (RJ45 ou borne de fil)
*** Liaison équipotentielle
fr
* Ingresso: linea non protetta (RJ45 o morsetto per fili)
** Uscita: linea protetta (RJ45 o morsetto per fili)
*** Barra equipotenziale
it
* Ingang: onbeschermde kabel (RJ45 of draadklem)
** Uitgang: beschermde kabel (RJ45 of draadklem)
*** Potentiaalvereffening
nl
*Wejście: przewód niezabezpieczony (RJ45 lub zacisk
drutu)
** Wyjście: przewód zabezpieczony (RJ45 lub zacisk drutu)
*** Wyrównanie potencjałów
pl
*
*
**
**
***
Geschützte und ungeschützte Leitungen getrennt verlegen. de
Install protected and unprotected lines separately. en
Instalar las líneas protegidas separadas de las líneas no
protegidas.
es
Τοποθετήστε τα καλώδια με και χωρίς προστασία ξεχωριστά.el
Posez les câbles protégé et non protégé séparément. fr
Posare separatamente le linee protette e non protette. it
Installeer beschermde en onbeschermde kabels apart. nl
Przewody zabezpieczone i niezabezpieczone należy układać
osobno.
pl
Klemmen vorsichtig betätigen. de
Touch terminal clamps with
caution.
en
Manipular los terminales de
borne con cuidado.
es
Χειρίζεστε προσεκτικά τους
ακροδέκτες.
el
Actionnez les bornes avec
précaution.
fr
Applicare i morsetti con cura. it
Wees voorzichtig met de
klemmen.
nl
Ostrożnie nacisnąć zaciski. pl
Deutsch
Wichtige Informationen
Sicherheitshinweise
Warnung: Unsachgemäßer Umgang mit dem Gerät kann zu
einem lebensgefährlichen elektrischen Schlag führen und
das Gerät beschädigen oder zerstören.
Lesen Sie die zum Gerät gehörenden Anleitungen und bewahren
Sie diese auf.
Schließen Sie die Anschlusskabel des Geräts nur an die dafür
bestimmten und fachgerecht installierten Anschlussdosen an.
Verwenden Sie ausschließlich Originalzubehör und
Originalersatzteile.
Warnung: Beschädigte Anschlussleitungen sowie
Beschädigungen am Gehäuse und am Gerät selbst können
zu einem lebensgefährlichen elektrischen Schlag führen.
Nehmen Sie ein beschädigtes Gerät nicht in Betrieb.
Warnung: Die an das Überspannungsschutzmodul
angeschlossenen Telekommunikationsleitungen können
eine sehr hohe Klingelspannung erzeugen. Das Berühren
spannungsführender Leiterbahnen, Bauteile oder der
Telefonanschlüsse kann zu einem lebensgefährlichen elektrischen
Schlag führen.
Betreiben Sie das Überspannungsschutzmodul nur mit
geschlossenem Gehäuse.
Ziehen Sie vor der Montage des Geräts die Netzstecker/TAE-
Stecker/Westernstecker des Telefonanschlusses, der TK-Anlage
und der an die TK-Anlage angeschlossenen Endgeräte. Gehen
Sie später zum Öffnen des bereits installierten Geräts ebenso vor.
Betreiben Sie das Überspannungsschutzmodul nur an der Wand.
Beachten Sie auch EN 61643-21 vom Juli 2013 (Überspannungs-
schutzgeräte für den Einsatz in Telekommunikations- und
signalverarbeitenden Netzwerken)
Warnung: Die fachgerechte Installation von Erdungs-
anschlüssen an die Potentialausgleichsschiene oder die
Verbindung mit dem Schutzleiter innerhalb einer fest
eingebauten elektrischen Anlage wie zum Beispiel einer Steckdose
darf nur durch eine Elektrofachkraft durchgeführt werden.
Warnung: Das Überschreiten technischer Grenzwerte
(auch kurzzeitig) kann zur Beschädigung oder Zerstörung
des Geräts sowie der daran angeschlossenen Geräte
führen.
Überschreiten Sie nicht die in den technischen Daten
angegebenen Grenzwerte.
Warnung: Überspannungen, wie sie bei Gewitter auftreten,
können zu einem lebensgefährlichen elektrischen Schlag
führen oder das Gerät beschädigen oder zerstören.
Montieren Sie das Überspannungsschutzmodul nicht während
eines Gewitters. Verzichten Sie während eines Gewitters auch
auf das Trennen und Anschließen von Leitungen.
Lassen Sie von einer Elektrofachkraft alle Kabel innerhalb des
Gebäudes verlegen.
Wichtig: Das Gerät ist nicht dafür ausgelegt und sollte daher nicht
für lebenserhaltende Systeme und/oder Anwendungen innerhalb
nuklearer Einrichtungen eingesetzt werden. Einem Einsatz des
Geräts für solche Anwendungen muss zwingend eine auf den
Einzelfall zugeschnittene schriftliche Zustimmung/Erklärung des
Herstellers vorausgehen.
Nicht bestimmungsgemäße Verwendung kann z. B. zu
Funktionseinschränkungen oder Störungen, zur Zerstörung des
Geräts oder schlimmstenfalls zur Gefährdung von Personen führen.
Wenn Sie sich über die bestimmungsgemäße Verwendung auch
nach dem Lesen des folgenden Kapitels nicht sicher sind, fragen
Sie Ihren Fachhändler.
Lesen Sie die zum Gerät gehörenden Anleitungen und bewahren
Sie diese zum späteren Gebrauch auf.
Bestimmungsgemäße Verwendung
Bei den Geräten SG-100 und SG-200 handelt es sich um
Überspannungsschutzmodule, die für den Mittel- und Feinschutz
eingesetzt werden können. Diese Module schützen ihren Router,
das Modem, die Türsprechstelle oder das Telefon - im folgenden
TK-Gerät genannt - vor Schäden durch Überspannungen aus der
Anschlussleitung. Vor Blitzeinschlägen, die unmittelbar in die
Leitung abfließen, bieten die Module keinen ausreichenden Schutz,
falls der Grobschutz nicht durch Maßnahmen des Netzbetreibers (z.
B. im Splitter oder am Hausanschluss) gewährleistet wird.
Das SG-100 (Mittel- und Feinschutz) findet Verwendung für: ADSL
mit Splitter, ISDN Amtanschluss, analoger Amtanschluss,
abgesetzte analoge Nebenstelle, abgesetzte Up0-Nebenstelle oder
analoge Türsprechstelle. Dieses Gerät verfügt über einen
zweistufigen Schutz mittels Gasableiter und
Überspannungsschutzdioden.
Das SG-200 (Mittel- und Feinschutz) findet Verwendung für:
xDSL-Anschlüsse (All-IP: VDSL-Anschluss, ADSL-Anschluss ohne
Splitter). Dieses Gerät verfügt über einen dreistufigen Schutz mittels
Gasableiter, Überspannungsschutzdioden und kapazitiv
abgekoppeltem strombegrenzendem Feinschutz.
Wichtig: Das Überspannungsschutzmodul SG-100 ist für den
Anschluss an die Uk0-Schnittstelle (2-Draht-Leitung vor dem ISDN-
NTBA) geeignet. Beachten Sie dabei die Bestimmungen ihres
Netzbetreibers.
Wichtig: Die max. Betriebsspannung darf die angegebene höchste
Dauerspannung UC nicht überschreiten.
Wichtig: Vor ein SG-200 als Feinschutz muss dann ein SG-100 als
Mittelschutz gesetzt werden, wenn die Installation keinen
Mittelschutz, z. B. durch einen Splitter oder als Erdleitung
ausgeführt, enthält.
Technische Daten
SG-100 / SG-200 Allgemein
Schutzfunktionen
Abmessungen (B x H x T) 142 mm x 81 mm x 27 mm
Gewicht 106 g (SG-100), 111 g (SG-200)
Gehäuse Kunststoff (brandgeschützt),
schwarz
Temperatur (TU) Betrieb: -5 bis +40 ºC
Lagerung: -40 bis +70 ºC
Relative Luftfeuchtigkeit Betrieb: 5 % bis 95 %, nicht
kondensierend
Schutzart IP20
Prüfnorm EN 61643-21
Zolltarifnummer 85363010
Anschlussquerschnitt
Signaladern (eindrähtig /
feindrähtig)
0,2 bis 0,75 mm2
Anschlussquerschnitt
Erdungsklemme
0,5 bis 1,5 mm2
Anschluss RJ45 Pin 4 und 5
Spezifikation SG-100 SG-200
Ableiterklasse Type 2P1
Nennspannung (UN) 70 V AC /
100 V DC
20 V AC
Höchste Dauerspannung
DC (UC)
120 V ---
Umwelthinweise
Sollte das Gerät einmal ausgedient haben, achten Sie auf die fachgerechte
Entsorgung (nicht in den normalen Hausmüll).
Entsorgen Sie das Verpackungsmaterial im Interesse des
Umweltschutzes ordnungsgemäß.
Erkundigen Sie sich bei der Stadt- oder Gemeindeverwaltung nach
Möglichkeiten einer umwelt- und sachgerechten Entsorgung des
Geräts. Wenn Sie möchten, dass wir Ihnen die Entsorgung
abnehmen, senden Sie das Gerät auf Ihre Kosten an die Auerswald
GmbH & Co. KG.
Konformitätserklärung
Dieses Gerät entspricht den grundlegenden Gesundheits-,
Sicherheits- und Umweltanforderungen aller relevanten
europäischen Richtlinien. Die Konformitätserklärung kann im
Internet eingesehen werden.
Höchste Dauerspannung
AC (UC)
85 V 28 V
Nennstrom bei 45 °C (IL) <= 200 mA <= 60 mA
C2 Nennableitstoßstrom
5 kV (8/20 μs) gesamt (In)
5 kA 5 kA
C2 Nennableitstoßstrom
5 kV (8/20 μs) pro Ader (In)
<= 2,5 kA (Betrieb mit Drahtklemme)
<= 2 kA (Betrieb über RJ45-Buchse)
Schutzpegel Ad-Ad
bei C2 (UP)
<= 130 V <= 45 V
Schutzpegel Ad-PG
bei C2 (UP)
<= 230 V <= 230 V
Serienimpedanz pro Ader
(0 bis 30 MHz)
2,4 Ohm +-20% 3,8 Ohm resitiv
+-20% + 100 nF
kapazitiv
Grenzfrequenz Ad-Ad
(100 Ohm) (fG)
0 bis 100 MHz 35 kHz bis
80 MHz
Kapazität Ad-Ad (C) <= 10 pF <= 15 pF
Kapazität Ad-PG (C) <= 10 pF <= 10 pF
Impuls-Rücksetzzeit <= 160 ms <= 160 ms
Überlastungs-
Ausfallmodus
Modus 3 (Auftrennen der Leitung)
Garantiebedingungen
1. Die Auerswald GmbH & Co. KG, Vor den Grashöfen 1, 38162 Cremlingen,
Germany, gewährt als Hersteller auf dieses Produkt 24 Monate
Herstellergarantie ab Kaufdatum.
2. Dies bedeutet für Sie als Verbraucher: Wir garantieren, dass unsere Geräte
bei der Übergabe fehlerfrei sind und sorgen 24 Monate ab diesem Datum für
eine kostenlose Reparatur oder liefern kostenfrei Ersatz, falls ein
Herstellungsfehler auftritt und verzichten auf den durch Sie als Verbraucher zu
führenden Nachweis wie bei der gesetzlichen Gewährleistung, dass dieser
Fehler zum Zeitpunkt der Übergabe schon vorhanden war. Bei der Reparatur
oder der Ersatzlieferung verwenden wir entweder neue oder neuwertige Teile.
Dem Gerät evtl. entnommene Teile gehen in unser Eigentum über und dürfen
vernichtet werden.
3. Neben dieser Garantie stehen dem Kunden in vollem Umfang die
gesetzlichen Rechte aus der Mängelgewährleistung auf der Grundlage des
Kaufvertrages gegenüber dem Lieferanten zu. Die gesetzliche
Mängelgewährleistung betrifft aber im Gegensatz zu unserer Herstellergarantie
nur die Beschaffenheit zum Zeitpunkt des Verkaufs (Übergabe).
4. Sie können diese Garantie nur in Anspruch nehmen, wenn Sie das
fehlerhafte Gerät mit einem eindeutigen Kaufbeleg (Rechnung oder
Kassenbeleg) auf Ihre Kosten an die Auerswald GmbH & Co. KG bzw.
außerhalb Deutschlands an unseren Generalimporteur oder Distributor vor Ort
einsenden. Fügen Sie dieser Einsendung bitte eine ausführliche
Fehlerbeschreibung bei und geben Sie bitte auch für eventuelle Nachfragen
Ihre Telefonnummer an. Um Transportschäden zu vermeiden, sorgen Sie bitte
für eine geeignete Transportverpackung (z. B. Originalverpackung mit
Umkarton).
5. Ausgeschlossen von der Herstellergarantie sind Schäden, die durch
unsachgemäße Behandlung, Bedienungsfehler, Missbrauch, äußere Einflüsse,
Blitzschlag/Überspannung, Veränderungen des Produkts sowie Anbauten
entstehen. Des Weiteren ausgeschlossen sind Verschleißteile (z. B. Batterien,
Sicherungen, Akkus, Speicherkarten), sowie durch Verschleißteile
entstandene Schäden (z. B. durch das Auslaufen von Batterien). Ebenfalls
ausgeschlossen sind Transportschäden, Folgeschäden, Kosten für Ausfall-
und Wegezeiten.
6. Die Garantie erlischt bei Reparaturen durch nicht autorisierte Stellen.
Erstinbetriebnahme
Position und Erdung des Geräts: Anwendungsart Mittelschutz
Position: In dieser Anwendungsart ist das Modul SG-100 oder SG-
200 direkt hinter dem Eintritt der Fernmeldeleitungen in das Haus
einzusetzen. Damit wird die weitere Leitungsführung im Haus vor
Beschädigungen durch Überspannungen geschützt. An das Modul
im weiteren Verlauf der Leitung angeschlossene Geräte werden nur
dann ausreichend geschützt, wenn sie sich in unmittelbarer Nähe
befinden und die Erdung dieser Geräte direkt mit der Erdung des
Moduls verbunden ist.
Erdung: In der Anwendung als Mittelschutz ist die Erdung über eine
Leitung mit 1,5 mm2 bevorzugt direkt mit der Potentialausgleichs-
schiene oder über eine andere direkte metallische Verbindung mit
einem geringen Widerstand zur Potentialausgleichsschiene
durchzuführen. Zur Vermeidung von Beschädigungen durch einen
hohen Impulsstrom ist eine Führung der Erdung durch den FI-
Schutzschalter möglichst zu vermeiden.
Position und Erdung des Geräts: Anwendungsart Feinschutz
Position: In dieser Anwendungsart ist das Modul SG- 200 direkt
vor das zu schützende TK-Gerät einzusetzen. Fehlt ein
vorgeschalteter Mittelschutz, ist die Leitungsführung durch das
Haus bis zum Modul ungeschützt.
Erdung: In der Anwendung als Feinschutz ist die Erdung möglichst
direkt mit der Erdung des TK-Geräts zu verkoppeln. Eine separate
Führung der Erdkreise des TK-Geräts (erfolgt in der Regel über den
Schutzleiter) und des Moduls ist zu vermeiden. Es ist daher z. B.
sinnvoll, die Erdung des Moduls mit dem Schutzleiter der Steckdose
für das TK-Gerät zu verbinden. Für die Erdung ist eine Leitung mit
1,5 mm2 (Cu) ausreichend. Soll ein TK-Gerät ohne Erdung (z. B. ein
DSL-Router, eine Türsprechstelle oder ein abgesetztes Telefon)
geschützt werden, reicht eine einfache Verbindung zum
Schutzleiter.
Wichtig: Verlegen Sie die Leitung zum TK-Gerät nicht unmittelbar
neben einer Potentialausgleichsleitung oder den Kabeln zur TAE-
Dose/zum DSL-Splitter.
Wichtig: Führen Sie nach der Installation einen Neustart des
Routers durch.
English
Important Information
Safety Information
Warning: Handling the device improperly can cause a life-
threatening electrical shock, or damage or destroy the
device.
Read the instructions for the device and keep them for future
reference.
Only connect the device's connection cables to wall sockets that
are designed for that purpose, and that have been properly
installed.
Only use original accessories and original replacement parts.
Warning: Damaged connecting cables, or damage to the
casing or the device, can cause life-threatening electrical
shocks.
Never use a damaged device.
Warning: The telecommunications lines connected to the
overvoltage protection module can generate an extremely
high bell voltage. Touching live conductors, components or
telephone connections may cause a life-threatening electric shock.
Only operate the overvoltage protection module when its casing is
closed.
Before mounting the device, unplug the power plugs, TAE
connectors and western plugs on the telephone connection, pBX
and end devices connected to the pBX. Follow the same
procedure if you need to open a device that has already been
installed.
Only operate the overvoltage protection module when it is
mounted on the wall.
Also comply with EN 61643-21, July 2013 (Surge protective
devices connected to telecommunications and signalling
networks).
Warning: Only a qualified electrician is permitted to install
earthing connections on the potential compensation bar or
the connection with the protective earth conductor in a
permanently installed electrical device such as a mains socket.
Warning: If technical threshold values are exceeded (even
briefly), this can damage or even destroy the device, and
also the devices connected to it.
Never exceed the threshold values stated in the technical data.
Warning: Power surges, which can occur during electrical
storms, can cause life-threatening electric shocks, or
damage or destroy the device.
For this reason, do not mount the overvoltage protection module
during an electrical storm. Do not connect or disconnect power
cables during an electrical storm.
Arrange for a qualified electrician to install all the cables inside the
building.
Important: The device is not designed or intended for use in life-
support systems and/or nuclear facilities. The device can only be
used for these purposes with prior written permission/clarification
from the manufacturer in each individual case.
Improper use may, for example, cause functional restrictions or
malfunctions, the destruction of the device or, in a worst case
scenario, personal injury.
If you are still uncertain about how to use the product properly
after reading the section below, please contact your specialised
dealer.
Read the manuals for the device and keep them for future
reference.
Proper Use
The SG-100 and SG-200 devices are overvoltage protection
modules which can be used for medium and fine protection.
These modules protect your router, the modem, the door terminal or
the telephone (referred to as the "telecomms device" below) against
damage by power surges from the connecting cable. These
modules do not provide adequate protection against lightning strikes
that flow directly into the line, if coarse protection is not ensured by
measures implemented by the network provider (e.g. in the splitter
or on the domestic connection).
The SG-100 (medium and fine protection) is used for: ADSL with
splitter, ISDN exchange line connection, analogue exchange line
connection, remote analogue extension, remote Up0 remote
extension or analogue door terminal. This device has two-level
protection, using gas discharge tubes and power surge protection
diodes.
The SG-200 (medium and fine protection) is used for: xDSL
connections (All-IP: VDSL connection, ADSL connection without
splitter). This device has three-level protection, using gas discharge
tubes, power surge protection diodes and capacitively disconnected
current-limiting fine protection.
Important: The SG-100 overvoltage protection module is suitable
for connection to the Uk0 interface (2-wire line before the ISDN NT
(network termination for basic access)). For information, refer to
your network provider's documentation.
Important: The max. operating voltage must not exceed the stated
highest continuous voltage UC.
Important: If the installation does not provide any medium
protection such as by means of a splitter or earth wire, an SG-100
must always be installed for medium protection before an SG-200
that provides fine protection.
Technical Data
SG-100/SG-200 General
Protective functions
Dimensions (WxHxD) 142 mm x 81 mm x 27 mm
Weight 106 g (SG-100), 111 g (SG-200)
Casing Plastic (fire-proof), black
Temperature (TU) Operation: -5 to +40 ºC
Storage: -40 to +70 ºC
Relative humidity Operation: 5 % to 95 %, non-
condensing
Protection rating IP20
Test standard EN 61643-21
Customs tariff number 85363010
Signal cores: connection
cross-section (single-wire/
fine-stranded)
0.2 to 0.75 mm2
Earthing terminal
connection cross-section
0.5 to 1.5 mm2
RJ45 connection Pin 4 and 5
Specification SG-100 SG-200
Surge arrester class Type 2P1
Rated voltage (UN) 70 V AC/
100 V DC
20 V AC
Highest continuous voltage
DC (UC)
120 V ---
Highest continuous voltage
AC (UC)
85 V 28 V
Rated current at 45 °C (IL) <= 200 mA <= 60 mA
Environmental Notices
If you want to dispose of the device, please ensure its professional disposal. Do
not put it in the normal household waste.
Dispose of the packaging material properly and in interest of the
environmental protection.
Consult your responsible authority for information about the
professional and environment-friendly disposal of your device. If you
want that we handle the disposal for you, you can send the device at
your costs to Auerswald GmbH & Co. KG.
Declaration of Conformity
This device complies with the basic health, safety and
environmental requirements in all relevant EU directives. You can
view the Declaration of Conformity on the Internet.
Conditions of Guarantee
1. Auerswald GmbH & Co. KG, Vor den Grashöfen 1, 38162 Cremlingen,
Germany, grants 24 months Manufacturer's Warranty from the date of
purchase, as the manufacturer of this product.
2. For you, as a consumer, this means: We guarantee that our devices are
error-free when supplied. If a manufacturing error is identified within 24 months
of the delivery date we will repair or replace the device free of charge without
you, as the consumer, having to provide the usual legally required proof that this
C2 rated discharge surge
current
5 kV (8/20 μs) Total (In)
5 kA 5 kA
C2 rated discharge surge
current
5 kV (8/20 μs) per core (ln)
<= 2.5 kA (operation with wire
terminal)
<= 2 kA (operation via RJ45 socket)
Protective level core-core
at C2 (UP)
<= 130 V <= 45 V
Protective level core-PG
at C2 (UP)
<= 230 V <= 230 V
Serial impedance per core
(0 to 30 MHz)
2.4 Ohm +-20% 3.8 Ohm resistive
+-20% + 100 nF
capacitive
Cut-off frequency core-core
(100 Ohm) (fG)
0 to 100 MHz 35 kHz to
80 MHz
Capacity core-core (C) <= 10 pF <= 15 pF
Capacity core-PG (C) <= 10 pF <= 10 pF
Pulse reset time <= 160 ms <= 160 ms
Overload failure mode Mode 3 (disconnect line)
fault was present when you received the device. We either use new parts or
parts in mint condition for the repair or replacement delivery. Any parts removed
from the device become our property and can be destroyed by us.
3. In addition to this warranty, you have the unlimited legal right to claim against
the supplier on the basis of the terms of the warranty for defects on the basis of
the purchase contract. However, in contrast to our Manufacturer's Warranty, the
legal warranty for defects only applies to the device's state when sold
(handover).
4. You can only claim against this warranty if you return the faulty device to
Auerswald GmbH & Co. KG or our local general importer or distributor, outside
Germany, at your own cost, with a valid proof of purchase (invoice or till receipt).
When you return it to us, please provide a detailed description of the fault that
has occurred, and also tell us your telephone number, in case we need to
contact you. To prevent shipping damage, provide suitable transport packaging
(e.g. original packaging with a secondary shipping box).
5. The Manufacturer's Warranty excludes damage caused by mishandling,
operating errors, misuse, external influences, lightning strikes/power surges,
modifications to the product and extensions. Also excluded are wearing parts
(e.g. batteries, fuses, rechargeable batteries and memory cards) and damage
caused by wearing parts (e.g. if batteries go flat). Shipping damage,
consequential damage, and costs arising from down times and travel times are
also excluded.
6. The warranty is cancelled if repairs are carried out by unauthorised agents.
Initial Commissioning
Device positioning and earthing: medium protection
application type
Position: In this application type, the SG-100 or SG-200 module
needs to be installed directly at the location at which the telecomms
lines enter the house. This will then protect any other lines that run
through the house from being damaged by power surges. Any
devices connected to the module further along the line, only have
adequate protection if they are very close to the module and their
earths are connected to the module's earth.
Earthing: when used as medium protection, the earthing must
preferably be created with a line with diameter 1.5 mm2, connected
directly to the potential compensation bar, or via a different direct
low-resistance metal connection to the potential compensation bar.
To prevent damage by a high pulse current, the earthing should, if
at all possible, not pass through the RCCB.
Device positioning and earthing: Fine protection application
type
Position: In this application type, the SG-200 module needs to be
installed directly before the telecomms device that is to be protected.
If no medium protection is implemented before it, the lines running
through the house to the module will be unprotected.
Earthing: when used as fine protection, the earthing must be
connected to the earthing on the telecomms device, as directly as
possible. You should not run the earthing circuits on the telecomms
device (usually via the protective earth conductor) and the module
separately. For this reason, it is a good idea, for example, to connect
the module's earthing with the protective earth conductor in the
mains socket for the telecomms device. A line with diameter 1.5
mm2 (Cu) is sufficient for earthing. A simple connection to the
protective earth conductor is all that is required to protect a
telecomms device that does not have its own earthing (e.g. a DSL
router, door terminal or remote telephone).
Important: Do not install the line to the telecomms device close to
a ground cable or the cables to the TAE socket/DSL splitter.
Important: After installation, restart the router.
Español
Información importante
Indicaciones de seguridad
Advertencia: Si este dispositivo se utiliza de forma indebida
se corre el riesgo de provocar una descarga eléctrica
potencialmente mortal y daños en el dispositivo o su
destrucción.
Debe leer las instrucciones correspondientes al dispositivo y
guardarlas.
Los cables de conexión del dispositivo deben conectarse
únicamente a las cajas de conexión instaladas específicamente
para ellos.
Utilice exclusivamente repuestos y accesorios originales.
Advertencia: Las líneas de conexión dañadas, así como los
daños o desperfectos en la carcasa o el propio dispositivo,
pueden provocar descargas eléctricas potencialmente
mortales.
Jamás debe encender un dispositivo averiado o dañado para
hacerlo funcionar.
Advertencia: Las líneas de telecomunicación conectadas al
módulo protector de sobretensión pueden generar una
elevada tensión de timbre. Si se tocan pistas conductoras,
componentes en tensión o conexiones telefónicas se puede sufrir
una descarga eléctrica potencialmente mortal.
No utilice el módulo protector de sobretensión con la carcasa
abierta.
Antes de montar el dispositivo desconecte los enchufes de red/
conectores TAE/conectores RJ de la conexión telefónica, de la
centralita y de los terminales conectados a la centralita. Proceda
de la misma forma si más adelante tiene que abrir la carcasa del
dispositivo instalado.
Está prohibido hacer funcionar el módulo protector de
sobretensión si no está montado en la pared.
Respete también la norma EN 61643-21 de julio de 2013
(Dispositivos de protección contra sobretensiones transitorias de
baja tensión conectados a redes de telecomunicaciones y de
transmisión de señales).
Advertencia: Solo un técnico electricista puede realizar la
instalación correcta de las puestas a tierra a la barra
equipotencial, o bien al conductor protector integrado en una
instalación eléctrica fija, como una toma de corriente.
Advertencia: Sobrepasar los valores límite técnicos
(aunque sea por un breve espacio de tiempo) puede
provocar daños en el dispositivo y los dispositivos
conectados al mismo, o su destrucción.
No sobrepase los valores límite especificados en los datos
técnicos.
Advertencia: Las sobretensiones, como las que pueden
producirse en caso de tormenta eléctrica, pueden provocar
descargas eléctricas potencialmente mortales y dañar o
destruir el dispositivo.
No monte el módulo protector de sobretensión durante una
tormenta eléctrica. No conecte o desconecte las líneas durante
una tormenta eléctrica.
Debe encargar a un electricista el tendido de todos los cables en
el interior del edificio.
Importante: Este dispositivo no se ha concebido para trabajar con
sistemas de soporte vital o aplicaciones relacionadas con
instalaciones nucleares, por lo que no se debe utilizar para tales
fines. Si se pretende utilizar este dispositivo para finalidades de esa
naturaleza, es obligatorio contar con una autorización o aprobación
previa por escrito del fabricante que se adapte a las características
concretas del caso.
Utilizar este dispositivo para fines distintos de los previstos podría
conllevar limitaciones de su funcionamiento o averías y destruir el
dispositivo o, en el peor de los casos, comportar riesgos para la
seguridad de las personas.
Si después de leer el siguiente capítulo le quedan dudas sobre el
uso adecuado y previsto del dispositivo consulte a su distribuidor
especializado.
Debe leer las instrucciones correspondientes al dispositivo y
guardarlas para poderlas consultar posteriormente.
Uso previsto
Los dispositivos SG-100 y SG-200 son módulos protectores de
sobretensión previstos para la protección media y fina. Los
módulos protegen su router, el módem, el intercomunicador de
puerta o el teléfono (en lo sucesivo, "el dispositivo TC") de posibles
daños por sobretensión en la línea de conexión. Los módulos no
ofrecen protección suficiente ante impactos de rayos que se derivan
directamente a través de la línea, en caso de que la protección
basta no esté garantizada mediante medidas adoptadas por el
operador de red (p. ej., en el splitter o en la acometida del edificio).
El SG-100 (protección media y fina) se puede utilizar para: ADSL
con splitter, conexión RDSI de red pública, conexión analógica de
red pública, extensión analógica remota, extensión Up0 remota o
intercomunicador de puerta analógico. El dispositivo ofrece una
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Auerswald SG-200 Istruzioni per l'uso

Tipo
Istruzioni per l'uso
Questo manuale è adatto anche per