13
ENUSER MANUAL GI400 / GI410
4.10 NUMBER OF TICKET NTIC
With this function the user can print in the ticket a ticket number which is going to increase automatically at the end of the weight, (number of
delivery or number of ticket). Use the cursor keys for change the value and enter escape to exit or memorize..
4.11 WEIGHT MODE WHEiGt
The user access the normal mode of weighing again.
4.12 DOSAGE dOSIFI
PRECISE PLATE ADDED 4I/4O(relay)
With 4 inputs and 4 outputs. The dosing function is only available when the plate is correctly connected to the display.
The card has four relays with potential-free output up to 0.5A 125VAC or 2A 30VDC. With them you can check remote instruments such as relays, signal
lamps and PLC. The card also has four inputs. The 4 inputs are emulated to the keys of the equipment when they are in dosage mode. The dosing function
remains active until it is switched off.
The equipment is ready to dose automatically with two different possibilities: 1 product at two speeds or 2 products at one speed, with unload. The device
allows the pogramming, for each porduct, of the weight of the value of the thickness or product 1, and the value of the weight when the device works at
slow speed (that is the value of the smooth) or the value of the product 2.The device can also program a zone of unload where it is defined the value of the
dosage( to correct the blocking of the system because there is product left in the weighing zone).
When the equipment starts working it automatically functions with the last formula it has worked with. This allows the device to start again with its daily work.
When the user gets into the menu to program the dosage “doSiFi”, the following menu is going to appear on the screen:
doSiFi
reset YES / NO yes-no (It sets the process to zero, it also places all the weights to ZERO)
Prod1 W WEIGHT thick weight to program or weight of the product 1
Prod1 t TIME time of lack of material, if the weight on the screen does not change in this space of time,
it activates the relais of alarm.
Prod 2W WEIGHT smooth weight to program or weight of the product 2
Prod 2t TIME Time of lack of material
2 discw WEIGHT Maximum waste weight
TIME Time of zero, when the zero is activated a time to wait for the falling of the material
is also activated
2 disct
tArEC AUTO/NO Make, or not, auto tare when dosage starts
EnAbLE YES / NO
RESET
By selecting YES, all parameters are set zero.
By selecting NO, you can access directly to the parameters to modify them.
PROD1
It edits the values of the formula for the product 1. If the weight is programmed to 0, the equipment is going to dosify the product 2.
• W (Weight): The desired weight for this product is programmed.
• T (Timer): Time of lack of material, if the weight on the screen does not vary in this space of time, it is going to activate the alarm (RL4)
PROD2
It edits the values of the formula for the product 2. If the weight is programmed at 0, the equipment will dosify only the product 1.
• W (Weight): The desired weight for this product this product added to product 1 weight is programmed.
• T (Timer): Time of lack of material, if the weight on the screen does not vary in this space of time, it is going to activate the relais of
alarm. (RL4)