CAME FLUO SW2 FLUO SW3 Guida d'installazione

Tipo
Guida d'installazione
AUTOMATION FOR SWING DOOR
ASSEMBLY AND INSTALLATION MANUAL
FA00008-EN
FLUO-SW2
FLUO-SW3
LIGHT
HEAVY
EN English
FA00008-EN 10/2022
2
www.came.com
1. INTRODUCTION
Before you begin to install or start an automatic pedestrian doors, an inspection must be carried out on site by qualified
personnel, for making measurements of the compartment wall, door and drive.
This inspection is to assess the risk and to select and implement the most appropriate solutions according to the type of
pedestrian traffic (intense, narrow, one-way, bi-directional, etc..), The type of users (elderly, disabled, children, etc..), in the
presence of potential hazards or local circumstances.
To assist installers in applying the requirements of European Standard EN 16005 concerning the safe use of automatic
pedestrian doors, we recommend consulting the guides E.D.S.F. (European Door and Shutter Federation) available on
www.edsf.com.
1.1 GENERAL SAFETY INSTRUCTION
This installation manual is intended for professionally competent personnel only. Before installing the product, carefully read
the instructions.
Bad installation could be hazardous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the
environment or left within reach of children, as these are a potential source of hazard.
Before installing the product, make sure it is in perfect condition. Do not install the product in an explosive environment and
atmosphere: gas or inflammable fumes are a serious hazard risk.
Before installing the automations, make all structural changes relating to safety clearances and protection or segregation of
all areas where there is risk of being crushed, cut or dragged, and danger areas in general.
Make sure the existing structure is up to standard in terms of strength and stability. CAME is not responsible for failure to use
Good Working Methods in building the frames to be motorised or for any deformation occurring during use.
The safety devices (safety sensor, photocells, etc.) must be installed taking into account: applicable laws and directives, Good
Working Methods, installation premises, system operating logic and the forces developed by the motorised door.
Apply hazard area notices required by applicable regulations.
Each installation must clearly show the identification details of the automatic pedestrian door.
1.2 EC MARKING AND EUROPEAN DIRECTIVES
Automations for swing pedestrian door, are designed and manufactured in compliance with the safety
requirements of the European standard EN 16005 and are CE-marked in accordance with the
Electromagnetic Compatibility Directive (2014/30/UE).
The automation also include a Declaration of Incorporation according to the Machinery Directive
(2006/42/EC).
Pursuant to Machinery Directive (2006/42/CE) the installer who motorises a door or gate has the same obligations as the
manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The
technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of
manufacture of the pedestrian door);
- draft the EC declaration of conformity in accordance with Annex ll-A of the Machinery Directive and deliver it to the
customer;
- affix the CE marking on the power operated door in accordance with point 1.7.3 of Annex l of the Machinery
1.3 DECLARATION OF INCORPORATION
Machines Directive 2006/42/EC, Annex II-B
The Declaration of Incorporation of the automations for FLUO automatic doors is attached to the product together with this
manual.
All data and information contained in this manual have been drawn up and checked with the greatest care. However CAME
cannot take any responsibility for eventual errors, omissions or inaccuracies due to technical or illustrative purposes.
CAME reserves the right to make changes and improvements to their products. For this reason, the illustrations and the
information appearing in this document are not definitive.
This edition of the manual cancels and replaces all previous versions. In case of modification will be issued a new edition.
FA00008-EN 10/2022
3
www.came.com
2. TECHNICAL DATA
Technical data
FLUO-SW2
Model
LIGHT
(for internal use, not exposed to wind
pressure)
Product dimensions
(Height x Depth x Length)
82 x 117 x 443 mm
Maximum load:
200 kg x 0,8 m
Opening and closing time
2 6 s
Duty class
Intermittent operation
Continuous operation
S3 = 100%
Power supply
Rated power
Stand-by
100 240 Vac 50/60 Hz
40 W
8 W
Rated load
20 Nm
Protection Rating
IP 20
Operating temperature
-15 °C +50 °C
Parameter adjustment
Buttons and Display
Connections to control and safety
devices
Dedicated connecting terminals
Number of programmable terminals
4 (G1, G2, G3, G4)
Power output for accessories
12 Vdc (1A max)
Power output for electric locks and
electronic locks
12 Vdc (1A max) / 24 Vdc (0,5 A max)
Firmware update
USB standard
Function selector device
818XA-0074, 818XA-0075
Battery power device
818XC-0038
N.B. The technical data above refer to average conditions of use and cannot be certain in each case. Each automatic entrance
variables such as: friction, balancing and environmental conditions that may substantially change both the duration and the
quality of the operation of the automatic or some of its components, including the automation. The installer must to adopt
adequate safety coefficients for each particular installation.
FA00008-EN 10/2022
4
www.came.com
3. STANDARD INSTALLATION
Rif.
Code
Description
1
818SW-0010
818SW-0020
FLUO-SW2 automation (Light) for swing doors
FLUO-SW3 automation (Heavy) for swing doors
2
818XA-0040
Sliding arm
3
001MR8534, 001MR8570,
001MR8590
Safety sensor
4
001MR8204, 001MR8003,
001MR8106, 001MR8107
Opening sensor
5
818XA-0074, 818XA-0075
Electronic function selector
-
818XC-0038
Battery power device
Note: Components and codes are those most commonly used in systems for automatic swing doors. The full range of
equipment and accessories is also available in the sales list.
The given operating and performance features can only be guaranteed with use of CAME accessories and safety devices.
FA00008-EN 10/2022
5
www.came.com
4. ASSEMBLY PROCEDURE OF THE AUTOMATION
Check the stability, the weight of the leaf and that the movement is smooth and without friction (if necessary to reinforce the
frame). Any closing door device must be removed or completely deactivated.
Check the correct operation in case of installation on doors that divide environments at different pressures.
4.1 INSTALLATION OF FLUO-SW2 AUTOMATION WITH 818XA-0040 SLIDING ARM
Use the sliding arm to pull with doors which open inside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation.
 







Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
(H)
FLUO-SW2 automation
28
818XA-0040 + 818XA-0045
45
818XA-0040
62
818XA-0040 + 818XA-0047
Move the door manually, and verify the correct opening and closing smoothly.
Adjust the opening mechanical stop inside the sliding arm.
CLOSING OF THE AUTOMATION COVER
Fix the cover to the heads using the supplied screws.
FA00008-EN 10/2022
6
www.came.com
4.2 INSTALLATION OF FLUO-SW2 AUTOMATION WITH 818XA-0059 SLIDING ARM
Use the sliding arm to push with doors which open outside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation. If the leaf
width is reduced, shorten the sliding guide and the sliding arm.
Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
Move the door manually, and verify the correct opening and closing smoothly.
Adjust the opening mechanical stop inside the sliding arm.











CLOSING OF THE AUTOMATION COVER
Fix the cover to the heads using the supplied screws.
(H)
FLUO-SW2 automation
28
818XA-0059 + 818XA-0045
45
818XA-0059
62
818XA-0059 + 818XA-0047
FA00008-EN 10/2022
7
www.came.com
4.3 INSTALLATION OF FLUO-SW2 AUTOMATION WITH 818XA-0041 ARTICULATED ARM
Use the articulated arm to push with doors which open outside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the bracket of the articulated arm on the door, using the measurements shown in the figure.















Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
(H)
FLUO-SW2 automation
28
818XA-0041 + 818XA-0045
45
818XA-0041
62
818XA-0041 + 818XA-0047
Fix the articulated arm to the automation, and fix the other end of the articulated arm to the door.
Move the door in the closed position, and adjust the length of the half-arm [A] so that the angle between the two half-arms
[A] and [B] is the greater possible.
(*) To increase the opening force it is possible to reduce the angle and reduce the measurement of fixing of the articulated
arm, as shown in figure.
Move the door manually, and verify the correct opening and closing smoothly.
Install the opening mechanical stop (not supplied by us).
Note: the mechanical stop on the floor must be fixed in a visible position and must not create tripping hazard.
CLOSING OF THE AUTOMATION COVER
Fix the cover to the heads using the supplied screws.
FA00008-EN 10/2022
8
www.came.com
4.4 INSTALLATION OF FLUO-SW3 AUTOMATION WITH 818XA-0040 SLIDING ARM
Use the sliding arm to pull with doors which open inside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation.

  




 
Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
(H)
FLUO-SW3 automation
28
818XA-0040
45
818XA-0040 + 818XA-0047
62
818XA-0040 + 818XA-0048
Move the door manually, and verify the correct opening and closing smoothly.
Adjust the opening mechanical stop inside the sliding arm.
CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.
FA00008-EN 10/2022
9
www.came.com
4.5 INSTALLATION OF FLUO-SW3 AUTOMATION WITH 818XA-0059 SLIDING ARM
Use the sliding arm to push with doors which open outside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation. If the leaf
width is reduced, shorten the sliding guide and the sliding arm.
Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
Move the door manually, and verify the correct opening and closing smoothly.
Adjust the opening mechanical stop inside the sliding arm.
 


CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.
(H)
FLUO-SW3 automation
28
818XA-0059
45
818XA-0059 + 818XA-0047
62
818XA-0059 + 818XA-0048
FA00008-EN 10/2022
10
www.came.com
4.6 INSTALLATION OF FLUO-SW3 AUTOMATION WITH 818XA-0041 ARTICULATED ARM
Use the articulated arm to push with doors which open outside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using screws with a diameter 4.8 mm,
using the measurements shown in the figure. Refer to the axis of the door hinges.
Fix the bracket of the articulated arm on the door, using the measurements shown in the figure.

 











Note: if necessary, you can change the measure H, between the automation and the door, by replacing the spacer, using the
codes listed in the table.
(H)
FLUO-SW3 automation
28
818XA-0041
45
818XA-0041 + 818XA-0047
62
818XA-0041 + 818XA-0048
Fix the articulated arm to the automation, and fix the other end of the articulated arm to the door.
Move the door in the closed position, and adjust the length of the half-arm [A] so that the angle between the two half-arms
[A] and [B] is the greater possible.
(*) To increase the opening force it is possible to reduce the angle and reduce the measurement of fixing of the articulated
arm, as shown in figure.
Move the door manually, and verify the correct opening and closing smoothly.
Install the opening mechanical stop (not supplied by us).
Note: the mechanical stop on the floor must be fixed in a visible position and must not create tripping hazard.
CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.
FA00008-EN 10/2022
11
www.came.com
5. ELECTRICAL CONNECTIONS

 






















Rif.
Code
Terminals
Description
1
88018-0036
MAINS IN
Cable for connection to the power supply.
2
-
-
PWR
PWR
Switching power supply 36V 65W (for FLUO-SW2 automation)
Switching power supply 36V 75W (for FLUO-SW3 automation)
3
119RIP155
Electronic control
4
-
-
MOT
MOT
Brushless motor (for FLUO-SW2 automation)
Brushless motor (for FLUO-SW3 automation)
ENC
Angular sensor
5
818XC-0038
BAT
Battery power device
5.1 GENERAL SAFETY ELECTRICAL PRECAUTIONS
Installation, electrical connections and adjustments must be completed in conformity with Good Working Methods and with
regulations in force.
Before making power connections, check that the rating corresponds to that of the mains supply. A multipolar disconnection
switch with a contact opening gap of at least 3 mm must be included in the mains supply. This switch must be protected from
unauthorized activations.
Check that, upstream of the electrical installation, an adequate residual current circuit breaker and an overcurrent cut out
are fitted.
Connect the automation to an effective earthing system carried out as indicated by current safety regulations.
During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the
electrical parts. To handle electronic parts, wear earthed antistatic conductive bracelets.
CAME declines all responsibility in the event of components which are not compatible with the safe and correct operation of
the product.
For repairs or replacements of products only original spare parts must be used.
FA00008-EN 10/2022
12
www.came.com
5.2 POWER SUPPLY ELECTRICAL CONNECTION
The connection to the mains supply can be done in one of the two following ways.
1) ELECTRICAL CONNECTION THROUGH THE AUTOMATION BASE
Use the electric cable and the supplied terminals for the connection to the mains supply through a channel in the wall,
previously made. Note: Shorten the electric cable to the desired size.
Make sure there are no sharp edges that might damage the electric cable.
For the connection to the mains supply use an independent channel, separated from the connections to control and safety
devices.

2) ELECTRICAL CONNECTION THROUGH THE AUTOMATION END CAP
If the path of the electric cable is outer the wall, drill the end cap on the suitable area, fix the electric cable using a supplied
PG9 cable gland.
Connect the electric cable to the junction box (using the supplied terminals), or connect the electric cable to the wall socket
using an electrical plug (not supplied by us).


FA00008-EN 10/2022
13
www.came.com
5.3 ELECTRONIC CONTROL TERMINALS

















Note: The terminals with the same number are equivalent.
The electronic control comes with the jumpers on the terminals with an asterisk [*]. When connecting safety devices remove
the jumpers of the corresponding terminals.
Terminals
Description
0 1
Output 12 Vdc for external powering accessories. The maximum absorption of 1 A corresponds to the
sum of all the terminals 1 (+12V).
1 3A
Contact N.O. opening A side (interior side).
1 3B
Contact N.O. opening B side (outer side).
1 8A
Closing safety contact N.C. The opening of the contact causes the reversal of the movement.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 8A.
1 6A
Opening safety contact N.C. The opening of the contact stops the movement during the opening phase;
the door closes after 3s. If the automation is closed, the opening of the contact prevents the opening.
Note: connect safety devices with test (see terminal 41), and remove the jumper 41 - 6A.
41
Test output (+12 V). Connect the safety devices with test (in accordance with EN 16005), as indicated in
the following chapters.
Note: in case of devices without test, connect the N.C. contact to terminals 41 - 8A or 41 - 6A.
1 G1/G2/G3/G4
0 G1/G2
Input terminal provided for general use.
Output terminal (12 Vdc, 30 mA max) provided for general use.
Using the ADV > STG1/STG2/STG3/STG4 menu you can choose a specific function to the G1/G2/G3/G4
terminal.
0 1 H L
Bus connection to the function selector.
+LK / -LK
Output 12Vdc (1 A max) / 24Vdc (0,5 A max) for electric lock.
USB
USB standard. Allows saving the door settings and loading the firmware updates.
SD
Micro SD standard. Allows saving the door settings and loading the firmware updates.
COM
Connection for remote communication
Buttons
Description
OPEN
Open the door.
Scroll the menu and increase of selected values.
Scroll the menu and reduction of selected values.
ENTER
Button to select the menu and save the selected data.
ESC
Exit the menu.
FA00008-EN 10/2022
14
www.came.com
5.4 ELECTRICAL CONNECTION OF FUNCTION SELECTOR
Connect the 0-1-H-L terminals of the function selector, by cable (not supplied by us), to the 0-1-H-
L terminals of the electronic control.
Note: for lengths over 10 m, use a cable with 2 twisted-pairs.
ATTENTION: the function selector must be used by authorized personnel only; if it is installed in a
place accessible to the public, the function selector must be protected by a proximity badge
(13.56MHz ISO15693 and ISO14443 Mifare) or by a numeric code (max 50 badges and codes).
The function selector allows the following settings.
Simbolo
Description
OPEN DOOR
When selected, the symbol lights up, the door is permanently open.
Note: the leaves can still be handled manually.
AUTOMATIC PARTIAL OPERATION
In the case of a door with 2 automations, when selected, the symbol lights and allows the automatic
operation of only one leaf.
AUTOMATIC BI-DIRECTIONAL OPERATION
When selected, the symbol lights up, the door works automatic in bidirectional mode.
RESET
Select the symbol for 5 seconds, the automation performs the self-test and the automatic learning.
AUTOMATIC ONE-WAY OPERATION
When selected, the symbol lights up and automatic operation of the door is in one-way mode.
CLOSED DOOR
When selected, the door is permanently closed.
Note: using the menu SEL > DLAY you can adjust the delay time to close the door.
MANUAL OPERATION (ADV > HAND = MIN/MAX)
Select the symbol for 3 seconds, the symbol flashes and the door can be moved manually.
PROTECTED FUNCTION SELECTOR
The symbol lights up if the function selector is protected. To activate the temporary operation of the
function selector is necessary to approach the badge to the NFC symbol (818XA-0074), or enter the code
(818XA-0075), or select for 3 seconds the logo.
ACTIVATION OF FUNCTION SELECTOR BY LOGO (SEL>SECL=LOGO)
Select the logo for 3 seconds (the lock symbol light off), the function selector is activated for 10 seconds.
Expired the time the function selector switches off (the lock symbol lights up).
ACTIVATION OF FUNCTION SELECTOR BY BADGE (SEL>SECL=TAG)
Approach the badge to the NFC symbol (the lock symbol light off), the function selector is activated for 10
seconds. Expired the time the function selector switches off (the lock symbol lights up).
1 2 3 4 5
ACTIVATION OF FUNCTION SELECTOR BY NUMERIC CODE (SEL>SECL=TAG)
Press the logo, enter the code (maximum 5 numbers), press the logo for confirmation, (the lock symbol
light off), the function selector is activated for 10 seconds. Expired the time the function selector switches
off (the lock symbol lights up).
BATTERY SIGNAL
Battery symbol off = the door is operating with the mains supply
Battery symbol on = the door is operating with battery power
Battery symbol flashing = the battery is low or disconnected
INFORMATION SIGNAL
Information symbol on = it is necessary to perform the ordinary maintenance of the door.
Information symbol flashing = shows the presence of alarms:
- 1 flash = failure of electronic control or locking device;
- 2 flashes = mechanical failure;
- 3 flashes = failure of sensor safety test;
- 4 flashes = motor overtemperature.
FA00008-EN 10/2022
15
www.came.com
5.5 ELECTRICAL CONNECTION OF OPENING SENSOR

















Connect the sensor, using the supplied cable to the terminals of the electronic control as follows:
119RIP155
001MR8204
001MR8106, 001MR8107
001MR8106 NEW
001MR8003
OPENING
0
Brown
Brown
Black
Grey
1
Green
Green
Red
Grey
Yellow
Yellow
Yellow
Yellow
3A (3B)
White
White
Yellow
White
SAFETY
0
Blue
1
Pink
8A
Grey
41
Red
For more information, check the installation manual of the sensor.
FA00008-EN 10/2022
16
www.came.com
5.6 ELECTRICAL CONNECTION OF SAFETY SENSOR
The safety sensors should be installed directly on the leaf of the door, and protect both the opening and the closing of the
swing door.
To simplify the installation of the safety sensors, you can choose one of the following two options.
- OPTION 1: Connect the 2 sensors to each other, using the supplied cable. Connect only one of the 2 sensors to the
electronic control terminals, as shown below.















-
-
001MR8534, 001MR8570, 001MR8590
SAFETY
0
SAFETY
0
Brown
Blue
1
1
Green
Pink
6A
8A
Purple (DIP1=OFF)
41
41
Red
- OPTION 2: Connect each sensor to the electronic control terminals, as shown below.



























-
-
001MR8534, 001MR8570, 001MR8590
SAFETY
0
SAFETY
0
Brown
Blue
1
1
Green
Pink
6A
8A
Purple (DIP1=OFF)
41
41
Red
For more information, check the installation manual of the sensor.
FA00008-EN 10/2022
17
www.came.com
SAFETY SENSOR
FA00008-EN 10/2022
18
www.came.com
5.7 ADJUSTMENT OF THE KINETIC ENERGY OF THE DOOR
To reduce the kinetic energy of the door in area B not protected by safety sensors, make the following adjustments.
Adjust the opening speed (VOP) so as to open the door (from 0° to 80°) at the times indicated in the table.
Adjust the closing speed (VCL) so as to close the door (from 90° to 1) at the times indicated in the table.
Time [s]
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
B [m]
0,16
0,24
0,32
0,40
0,48
0,56
0,64
0,72
0,80
0,88
0,95
Lm [m]
A [m]
0,7
0,54
0,46
0,38
0,30
0,22
0,14
0,06
-
-
-
-
0,8
0,64
0,56
0,48
0,40
0,32
0,24
0,16
0,08
-
-
-
0,9
0,74
0,66
0,58
0,50
0,42
0,34
0,26
0,18
0,10
0,02
-
1,0
0,84
0,76
0,68
0,60
0,52
0,44
0,36
0,28
0,20
0,12
0,05
1,1
0,94
0,86
0,78
0,70
0,62
0,54
0,46
0,38
0,30
0,22
0,15
1,2
1,04
0,96
0,88
0,80
0,72
0,64
0,56
0,48
0,40
0,32
0,25
1,3
1,14
1,06
0,98
0,90
0,82
0,74
0,66
0,58
0,50
0,42
0,35
1,4
1,24
1,16
1,08
1,00
0,92
0,84
0,76
0,68
0,60
0,52
0,45
1,5
1,34
1,26
1,18
1,10
1,02
0,94
0,86
0,78
0,70
0,62
0,55
5.8 LOW ENERGY
To reduce the force and kinetic energy of the door, make the following adjustments.
FLUO-SW2: adjust the force PUSH ≤ 10.
FLUO-SW3 with sliding arm: adjust the force PUSH ≤ 5.
FLUO-SW3 with articulated arm: adjust the force PUSH ≤ 3.
Adjust the opening speed (VOP) so as to open the door (from 0° to 80°) at the times indicated in the table.
Adjust the closing speed (VCL) so as to close the door (from 90° to 1) at the times indicated in the table.
Door weight [kg]
 



50
60
70
80
90
Lm [m]
Time [s]
0,75 m
3,0
3,0
3,0
3,0
3,5
0,85 m
3,0
3,0
3,5
3,5
4,0
1,00 m
3,5
3,5
4,0
4,0
4,5
1,20 m
4,0
4,5
4,5
5,0
5,5
FA00008-EN 10/2022
19
www.came.com
5.9 ELECTRICAL CONNECTION OF A DOOR WITH 2 LEAVES
To coordinate the operation of two automatic swing doors with the closing overlap of the leaves (see figure), procedures as
follows.
Using a 3-wire cable (1-H-L), connect the 2 automations MASTER-SLAVE, as shown in the figure.
Network addresses must be assigned using the ADV > ID menu, as shown in the figure.
Using the menu of the electronic control, set: ADV> SYNC> MST1 on MASTER automation and ADV> SYNC> SLV1 on SLAVE
automation.
Connect the opening sensors as described in chapter 5.5 and connect the safety sensors as described in chapter 5.6.
If desired, connect the function selector, as shown in the figure.
Note: the partial opening of only one leaf is referred to the MASTER automation.


































FA00008-EN 10/2022
20
www.came.com
5.10 ELECTRICAL CONNECTIONS OF ELECTRIC LOCK
Automations for swing doors are compatible with most of the electric locks available in the market. Verify that power supply
of the electric lock is 12Vdc (1 A max) or 24Vdc (0,5 A max).
- Connect the electric lock to terminals LK + and LK of the electronic control.
- Set the electric lock power supply, using menu: ADV > LKPW > 12Vdc or 24Vdc.
- Set the type of electric lock operation, using menu: ADV > ELLK > LOCK or SAFE/AUTO.
- Set the operating time of the electric lock, using menu: ADV > TRLK > from 0,5 to 5,0 seconds.
- Set the start of the door opening delay time, using menu: ADV > TALK > from 0,5 to 5,0 seconds.
In the figure are shown the timing of the electric lock operation:
A = start of opening pulse and electric lock power supply on/off,
B = start of door opening,
C = end of electric lock power supply on/off.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

CAME FLUO SW2 FLUO SW3 Guida d'installazione

Tipo
Guida d'installazione