KaWe QM-1-025O Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

QM-1-025O
Gebrauchsanweisung Stethoskope
User‘s Manual Stethoscopes
Mode d’emploi Stéthoscopes
Istruzioni per l’uso Stetoscopi
Instrucciones de empleo Estetoscopios
Manual de operação Estetoscópios
Руководство по применению Стетоскопы
Bitte lesen Sie diese Gebrauchsanweisung vor der Benutzung sorgfältig und vollständig durch
und beachten Sie die Pflegehinweise.
Please read this User‘s Manual thoroughly and carefully before attempting to use this product
and heed the given care instructions.
Lisez ce mode d‘emploi attentivement et entièrement avant d‘utiliser l‘appareil et respectez les
consignes d‘entretien.
Si prega di leggere attentamente queste istruzioni per l‘uso prima di utilizzare lo strumento e di
seguire i consigli per la manutenzione.
Por favor, lea con atención las presentes instrucciones de empleo en su totalidad y siga las
indicaciones referentes al cuidado del aparato.
Antes de utilizar este produto pela primeira vez, favor de ler com muita atenção todo este manual de operação e
observar as indicações relativas à manutenção.
Перед использованием следует полностью и внимательно прочитать настоящее
руководство по применению и соблюдать указания по уходу!
Deutsch
English
Français
Italiano
Español
Português
Русский
6-9
10-13
14-17
18-21
22-25
26-29
30-33
4
z.B. Noroscop umschaltbar
ex. Noroscop dual-function
p.ex. Noroscop commutable
ad es. Noroscop con canale selezionabile
p.ej. estetoscopio Noroscop con válvula selectora
por ex. Noroscop comutável
например: Noroscop с переключаемой головкой
Lautstärke | volume | intensité sonore | volume |
intensidad sonora | intensidade sonora | сила звука
Trichter | bell | cloche | campana | campana | campânula | воронка
Membran | diaphragm | membrane | membrana | diafragma | diafragma | мембрана
Frequenz | frequency | fréquence | frequenza |
frecuencia | frequência | частота
Suprabell (Veterinär)Schwestern-Lehr Duo
PetiphonSchwestern-Lehr Plano Petiphon
Pinard gr
Pinard klein
5
Planet
Top-Kardiology
Profi -Kardiology
Planet Air
Rapport/Rapport Black-Line
Prestige-Standard
Prestige-Child
Prestige-Baby
KaWe COLORSCOP Duo
KaWe COLORSCOP Plano
Prestige-Standard light
Prestige-Child light
Prestige-Baby light
Double
Single
6
Inhalt
1. Symbole in der Gebrauchsanweisung und auf der Verpackung ............................................................................7
2. Zweckbestimmung & bestimmungsgemäße Verwendung......................................................................................7
3. Sicherheitshinweise / Kontraindikationen ............................................................................................................................. 8
4. Bedienung ..............................................................................................................................................................................................8
5. Vorbereitende Maßnahmen zum Gebrauch .......................................................................................................................8
6. Hygienische Aufbereitung ............................................................................................................................................................8
Reinigung & Desinfektion............................................................................................................................................................................8
Sterilisation ...................................................................................................................................................................................................8
7. Lagerung & Transport ...................................................................................................................................................................... 9
Umgebungstemperatur ...............................................................................................................................................................................9
Aufbewahrung .............................................................................................................................................................................................9
8. Wartung und Service ........................................................................................................................................................................9
9. Zubehör und Ersatzteile .................................................................................................................................................................9
10. Entsorgung .............................................................................................................................................................................................9
11. Anhang......................................................................................................................................................................................................9
Gewährleistung ............................................................................................................................................................................................ 9
Kontakt .......................................................................................................................................................................................................... 9
7
Sehr geehrter Kunde, vielen Dank, dass Sie sich für ein Ka-
We-Produkt entschieden haben. Unsere Stethoskope zeichnen
sich durch eine hohe Qualität und Langlebigkeit aus. Diese Pro-
dukte erfüllen die Bestimmungen der Verordnung (EU)
2017/745 (europäische Medizinprodukte-Verordnung) und ge-
hören gemäß dieser Verordnung zur Medizinproduktklasse I.
Lesen und befolgen Sie diese Gebrauchsanweisung
und bewahren Sie sie zum späteren Nachschlagen auf.
Machen Sie sich vor der Benutzung sorgfältig mit der Bedienung
vertraut und beachten Sie die Pfl egehinweise.
Falls über die Bedienung des Gerätes Zweifel entstehen sollten,
wenden Sie sich an den Kundendienst (Herstelleradresse siehe
Rückseite).
Abbildungen der verschiedenen Stethoskop-Modelle nden Sie
auf der Seite 4-5 in dieser Gebrauchsanweisung. Die Farb-Vari-
anten fi nden Sie in unserem Gesamtkatalog auf
https://www.kawemed.com/download/broschueren/ oder bei
Ihrem Fachhändler.
1. Symbole in der Gebrauchsanweisung und
auf der Verpackung
2.
Achtung
Gebrauchsanweisung beachten
Artikelnummer
Fertigungslosnummer, Charge
Seriennummer
Hersteller
CE-Kennzeichnung
GOST-R Zertifi zierung von Exportwaren nach Russland
Latexfrei
Entsorgung im Hausmüll
Trocken aufbewahren
Medizinprodukt
Zweckbestimmung & bestimmungsgemäße
Verwendung
Das Stethoskop ist ein Diagnostikinstrument und besteht aus
einem Ohrbügel, einem Schlauchsystem und dem Bruststück.
Angewendet wird es zur Auskultation (Abhören) der Herztöne/
-geräusche, der Lungengeräusche sowie anderer hörbarer vi-
taler Parameter. Das Stethoskop ist je nach Untersuchung auf
die gewünschte Körperregion aufzulegen und unter geringem
Druck zu verwenden. Bei doppelseitigen Stethoskopen kann
durch Umschalten der Eingangskanal (Trichter oder Membran)
gewählt werden.
Die Beachtung aller Hinweise in dieser Gebrauchsanweisung
sowie der maßgeblichen Vorschriften und Richtlinien gehört
zur bestimmungsgemäßen Verwendung. Jede andere Verwen-
dung ist nicht bestimmungsgemäß und für hieraus resultieren-
de Schäden haftet der Hersteller nicht!
Vorgesehene Patientengruppe: Erwachsene, Kinder und Klein-
kinder.
Dieses Produkt darf ausschließlich durch autorisiertes Fachper-
sonal angewendet werden!
8
3. Sicherheitshinweise / Kontraindikationen
Stethoskope niemals ohne Ohroliven aufsetzen, um
Verletzungen zu vermeiden! Ist der Gummi beschädigt oder
hat er sich abgelöst, müssen die Ohroliven vor der nächsten
Verwendung ersetzt werden.
Bei den drehbaren Ohroliven ist die Gummihülle aufgesteckt.
Achten Sie vor der Anwendung stets auf einen festen Sitz.
Legen Sie das Stethoskop niemals in Flüssigkeiten.
Laute Geräusche können die Anwendung stören.
Eine Sterilisation im Autoklaven ist nicht möglich.
Die Stethoskope von extremen Temperaturen,
Lösungsmitteln und Ölen fernhalten.
Überpfen Sie das Stethoskop vor jedem Gebrauch
hinsichtlich seiner einwandfreien Funktion. Verwenden Sie
das Produkt nicht, wenn Sie Beschädigungen feststellen.
Verwenden Sie nur original Ersatz- und Zubehörteile von
KaWe.
4. Bedienung
Das Grundprinzip des Hörens durch ein Stethoskop ist „die
schwingende Luftsäule“. Es muss eine abgeschlossene Luftsäu-
le gebildet werden, damit eine Tonübertragung stattfinden
kann.
Beim Aufsetzen des Stethoskops mit Ohrbügel stellen Sie die
Ohrgelrohre so, dass die Ohroliven etwas nach vorne – zur
Nase des zu Untersuchenden – gerichtet sind, damit ein der
Anatomie des Ohrs entsprechender Sitz in den Gehörgang
gegeben ist.
Legen Sie die Membran bzw. den Trichter auf die zu
untersuchende Stelle auf. Folgende Modelle verfügen über
eine Doppelfunktion Membran/Trichter:
- Planet & Planet Air
- Prestige & Prestige light
- Double
- Rapport
- Profi-Kardiologie
- KaWe COLORSCOP Duo
- Schwestern-Lehr-Stethoskop Duo
Über eine Drehbewegung am Stethoskop-Kopf kann
zwischen Trichter und Membran gewählt werden. Ist die
Membran geöffnet, ist der Trichter geschlossen und
umgekehrt.
Stethoskope mit einem Membrankopf werden verwendet um
entweder die Auskultation an allen anatomisch nicht planen
Stellen durchzuführen und/oder dann, wenn die tiefen
Frequenzbereiche des Auskultation-Signals keine oder eine
unbedeutende Rolle spielen.
Der Trichter am Bruststück wird verwendet um die tieferen
Frequenzen zu diagnostizieren. Insbesondere bei der
kardiologischen Auskultation ist dies erforderlich. Der Rand
des Trichters muss an allen berührenden Körperstellen
luftdicht aufliegen!
5. Vorbereitende Maßnahmen zum Gebrauch
Das Stethoskop auf Beschädigung (v. a. Membran, Schlauch
& Ohrgel inkl. Ohroliven) und Beschmutzung überprüfen.
Das System muss abgeschlossen sein.
Die Ohroliven auf einen korrekten Sitz überprüfen.
Die Ohrbügel individuell einstellen.
Wenn diese Prüfungen erfolgreich durchgeführt wurden, kann
das Stethoskop nach erfolgter hygienischer Aufbereitung an
Patienten angewendet werden.
6. Hygienische Aufbereitung
Es wird empfohlen das Stethoskop regelmäßig zu reinigen und
zu desinfizieren um Kreuzkontaminationen zu vermeiden.
Reinigung & Desinfektion
Nach jedem Patienten sollte das Stethoskop mit einer 70%igen
Alkohollösung (z. B. mit getränkten Tüchern) gereinigt und
desinfiziert werden. Beachten Sie dabei die Einwirkzeiten des
verwendeten Produkts!
Des Weiteren sollte regelmäßig eine gründliche Reinigung der
einzelnen Bestandteile des Stethoskops erfolgen. Verwenden
Sie dafür eine 70%ige Alkohollösung oder eine milde Seifenlö-
sung. Die Ohroliven und die Membran können für die gründliche
Reinigung abgenommen werden. Bei der Membran ziehen Sie
dafür den Haltering ab. Gehen Sie vorsichtig mit der Membran
um, um Beschädigungen zu vermeiden!
Setzen Sie das Stethoskop erst wieder zusammen, wenn alle
Teile trocken sind.
Eine automatische Reinigung ist nicht möglich!
Sterilisation
Stethoskope sind für Sterilisationsprozesse nicht geeignet!
Links- bzw. Rechtsdrehung
bei Planet & Planet Air
(Punkt Rot = Membran geöffnet)
180°-Drehbewegung
alle anderen Doppelkopf-Modelle
bei Prestige & Prestige light
(Ohrsymbol = geöffnete Seite)
9
7. Lagerung & Transport
Die Stethoskope staub-, feuchtigkeits- und kontaminationsge-
schützt lagern und transportieren.
Umgebungstemperatur
Raumtemperatur.
Keiner extremen Hitze oder Kälte aussetzen.
Aufbewahrung
Bewahren Sie das Stethoskop stets einzeln in einer Verpackung
(z. B. Standard PE-Beutel) auf. Der Beutel muss groß genug für
das Instrument sein, so dass der Verschluss nicht unter Span-
nung steht.
8. Wartung & Service
Das Ende der Produktlebensdauer wird normalerweise von Ver-
schleiß und Bescdigung durch den Gebrauch bestimmt. Be-
schädigte Teile müssen aussortiert und ersetzt werden!
Für eventuelle Reparaturen kontaktieren Sie bitte Ihren Fach-
händler.
9. Zubehör & Ersatzteile
Zubehör- und Ersatzteile fi nden Sie in unserem Gesamtkatalog
auf https://www.kawemed.com/download/broschueren/
oder bei Ihrem Fachhändler.
10. Entsorgung
Das Produkt muss gemäß der örtlichen Bestimmungen entsorgt
werden.
Entsorgung über den Hausmüll.
Hinweis an Anwender & Patienten
Alle in Zusammenhang mit dem Produkt auftre-
tenden schwerwiegenden Vorfälle sind unver-
züglich dem Hersteller und der zuständigen Be-
hörde des jeweiligen Mitgliedsstaats, in dem der
Anwender und/oder der Patient niedergelassen
ist zu melden.
11. Anhang
Gewährleistung
Bei ordnungsgemäßer Handhabung und Berücksichtigung un-
serer Gebrauchsanweisung sowie der Verwendung von Ka-
We-Originalteilen gilt die gesetzliche Gewährleistung von zwei
Jahren beginnend mit dem Verkaufsdatum.
Bei weiteren Fragen oder eventuellen Reparaturen wenden Sie
sich bitte an Ihren Fachhändler.
Kontakt
Wenden Sie sich an Ihren Fachhändler oder an den Hersteller
(Adresse siehe Rückseite).
Basis UDI-DI
4030155KaWe06SU
180°-Drehbewegung
alle anderen Doppelkopf-Modelle
bei Prestige & Prestige light
(Ohrsymbol = geöff nete Seite)
10
Table of contents
1. Symbols used in the application manual and on packaging ..................................................................................10
2. Purpose and intended use ..........................................................................................................................................................10
3. Safety rules/contraindications .......................................................................................................................................................11
4. Application ........................................................................................................................................................................................... 11
5. Preparing for operation ...............................................................................................................................................................11
6. Hygienic preparation .....................................................................................................................................................................11
Cleaning and disinfection .......................................................................................................................................................................... 11
Sterilization ................................................................................................................................................................................................. 11
7. Transportation and storage .......................................................................................................................................................12
Ambient temperature ................................................................................................................................................................................12
Storage ........................................................................................................................................................................................................12
8. Maintenance and Service ............................................................................................................................................................12
9. Accessories and Spare parts .......................................................................................................................................................12
10. Disposal ..................................................................................................................................................................................................12
11. Annex .......................................................................................................................................................................................................12
Warranty .....................................................................................................................................................................................................12
Contact information ................................................................................................................................................................................... 12
Bild
fehlt noch
11
We would like to thank our valued customers for their decision
to purchase a KaWe product. Our stethoscopes are characterized
by high quality and durability. Our products meet the require-
ments of Regulation (EC) 2017/745 (European Regulation on
Medical Devices) and are classifi ed as medical devices class I.
Please read this manual carefully, adhere to it strictly,
and keep it for future reference if necessary.
Before using the product, carefully study operation rules, especi-
ally care requirements.
If you have any questions, please contact the service depart-
ment (the manufacturer’s address is indicated on the back).
Images of the di erent stethoscope models are shown on
pages 4-5 of this application manual. Color options can be
found in the general catalog of our company at
https://www.kawemed.com/download/broschueren/ or can
also be viewed at your specialist dealer.
1. Symbols used in the application manual and
on packaging
2.
ATTENTION!
Please follow the User‘s Manual
Article number
Batch number
Serial Number
Manufacturer
CE mark
GOST-R certifi cation for export to Russia
Latex free
Disposal as household waste
Store in a dry place
Medical products
Purpose and intended use
The stethoscope is a diagnostic tool and consists of a headset,
sound tube and chest piece. It is used for auscultation of heart
sounds/murmurs, lung murmurs, and other audible parame-
ters. Depending on the type of examination, the stethoscope is
applied to the appropriate area of the body and used at low
pressure. On double-sided stethoscopes, you can choose one or
another input channel (funnel or membrane).
Intended use is the compliance with all instructions in this ap-
plication manual as well as basic rules and directives. The ma-
nufacturer does not accept any liability for damage resulting
from any other use.
Target patient groups: adults, children and infants.
The products must only be used by authorized specialized per-
sonnel.
12
3. Safety rules/contraindications
To avoid injury, do not use a stethoscope without ear tips! If
the rubber is damaged or has come off, the ear tips must be
replaced before the next use.
The rotatable ear tips have the rubber cover attached. Always
make sure that it is correctly positioned before use.
Do not touch water with stethoscope.
Loud sound can interfere with the perception of noise.
Do not sterilize in autoclaves.
Keep the stethoscope away from heat, solvents, and oils.
Before each use, please check whether the stethoscope is
operating properly. Do not use the device in case any damage
is detected.
Only original spare parts and accessories from KaWe may be
used.
4. Application
The basic principle of auscultating with a stethoscope is the
“fluctuating air column”. For sound transmission, a closed air
column must be formed.
When putting on a stethoscope with a headset, the bows are
applied so that the ear tips are directed slightly forward,
towards the examiner’s nose, so that the anatomical
structure of the ear contributes to their close contact with the
acoustic meatus.
Apply the membrane or funnel to the examined place. The
following models have a double function of membrane/
funnel:
- Planet & Planet Air
- Prestige & Prestige light
- Double
- Rapport
- Profi Cardiology
- KaWe COLORSCOP Duo
- Duo Stethoscope for nurse training
Funnel or membrane can be selected with a double
movement of the stethoscope head. If the membrane is
open, the funnel closes and vice versa.
Membrane-head stethoscopes are used either for
auscultation of anatomically curved places and/or in cases
where the low frequency ranges of the auscultation signal
are of little or no importance for the diagnosis.
The funnel on the chest is used for low frequency
diagnostics. In particular, this is required for cardiac
auscultation. The edges of the funnel must adhere tightly to
the entire examined part of the body.
5. Preparing for operation
Check the stethoscope for damage and contamination
(especially diaphragm, hoses and headset incl. ear-tips).
The system must be closed.
Check that the ear-tips are properly seated.
Individually adjust the headset.
After successful completion of the inspection and after appro-
priate hygienic preparation, the stethoscope can be used to ex-
amine patients.
6. Hygienic preparation
Clean and disinfect the stethoscope periodically to prevent cross
contamination.
Cleaning and disinfection
After examining each patient, the stethoscope is to be cleaned
and disinfected with a 70% alcohol solution (for example, a
soaked tissue). The duration of exposure of the agent used must
be taken into account.
Besides, perform a thorough cleaning of the individual compo-
nents of the stethoscope periodically. Use a 70% alcohol soluti-
on or a mild soap solution. For thorough cleaning the ear tips
and membrane may be removed. Remove the corresponding
retaining ring on the diaphragm. Handle the diaphragm with
care to prevent damage.
Reassemble the stethoscope components only after they are
completely dry.
Automatic cleaning is not allowed.
Sterilization
Stethoscopes are not suitable for sterilization processes.
Turn left or right
on Planet & Planet Air model
(red point = membrane open)
180° rotation
other double head models
Prestige & Prestige light model
(ear symbol = open side)
13
7. Transportation and storage
Stethoscopes are to be stored and transported protected from
dust, moisture and contamination.
Ambient temperature
Room temperature.
Do not expose to extreme heat or cold.
Storage
Store the stethoscope in a separate container (for example, in a
standard plastic bag). The bag is to be large enough to store the
instrument to avoid bends after closing the bag.
8. Maintenance and Service
The end of the useful life is usually determined by wear and tear.
Damaged parts are to be sorted out and replaced immediately.
For repairs, contact your specialist dealer.
9. Accessories and Spare parts
Accessories and spare parts can be found in the general catalog
of our company at
https://www.kawemed.com/download/broschueren/ or can
also be viewed at your specialist dealer.
10. Disposal
The product is to be disposed in accordance with local environ-
mental regulations.
Disposal as household waste.
Instructions for service personnel
and patients
In case of problems during the device use, it is
necessary to immediately contact the manu-
facturer and the competent authorities of the re-
levant member state of the Union, in which the
service personnel or the patient are located.
11. Annex
Warranty
In case of proper handling and adherence to the rules laid down
in this application manual, as well as the use of original KaWe
spare parts, the statutory warranty period of two years from the
date of sale is valid. For other questions and if repair is required,
contact your specialized dealer.
Contact information
Please contact your specialist dealer or directly the manu-
facturer (see back for address).
Basic UDI-DI
4030155KaWe06SU
14
Sommaire
1. Les symboles dans le mode d‘emploi et sur l‘emballage .........................................................................................14
2. Destination et utilisation conforme .....................................................................................................................................14
3. Règles de sécurité/contre-indications ...................................................................................................................................... 15
4. Utilisation .............................................................................................................................................................................................15
5. Préparation à l‘utilisation ...........................................................................................................................................................15
6. Préparation hygiénique ...............................................................................................................................................................15
Nettoyage/désinfection ............................................................................................................................................................................15
Stérilisation .................................................................................................................................................................................................15
7. Stockage et transport ....................................................................................................................................................................16
Température ambiante ..............................................................................................................................................................................16
Stockage ......................................................................................................................................................................................................16
8. Maintenance et service .................................................................................................................................................................16
9. Accessoires et pièces de rechange ..........................................................................................................................................16
10. Elimination ...........................................................................................................................................................................................16
11. Annexe ....................................................................................................................................................................................................16
Garanties .....................................................................................................................................................................................................16
Coordonnées ...............................................................................................................................................................................................16
15
Nous tenons à remercier nos chers clients pour leur décision
d‘acheter un produit KaWe. Nos sthoscopes sont de haute
qualité et durabilité. Nos produits répondent aux exigences du
Règlement (UE) 2017/745 (Règlement européen sur les disposi-
tifs médicaux) et d‘après ce Règlement sont class comme
dispositifs médicaux de classe I.
Lisez attentivement ce mode d‘emploi, suivez-le
strictement et conservez-le pour référence ultérieure
si nécessaire.
Avant d‘utiliser le produit, étudiez attentivement les règles d‘utili-
sation, en particulier les exigences d‘entretien.
Si vous avez des questions, veuillez contacter le service après-
vente (l‘adresse du fabricant est indiquée au dos).
Pour les illustrations des diff érents modèles de sthoscopes,
voir les pages 4-5 de ce mode d‘emploi Les options de couleurs
sont présentées dans le catalogue général de notre socté à
l‘adresse
https://www.kawemed.com/download/broschueren/, ils
peuvent également être consultés chez votre revendeur
spécialisé.
1. Explication des symboles :
2.
Attention
Respectez le mode d'emploi
Numéro de l'article
Numéro du lot de production
Numéro de série
Fabricant
Marquage CE
Certifi cation GOST-R pour l'exportation vers la Russie
Sans latex
Élimination avec les déchets ménagers
Conserver dans un endroit sec
Produits médicaux
Destination et utilisation prévue
Le stéthoscope est un instrument de diagnostic et se compose
de la lyre, du système de tuyaux fl exibles et du pavillon. Il est
utilisé pour l‘auscultation (écoute) des battements et souffl es
cardiaques, des souffl es pulmonaires et d‘autres paramètres
audibles. Selon le type d‘examen, le sthoscope est appliq
sur la zone appropriée du corps et utilisé à basse pression. Lors-
qu‘il s‘agit des sthoscopes à double tête, vous pouvez choisir
l‘un ou l‘autre canal d‘entrée (récepteur de son ou membrane).
Le respect de toutes les instructions de ce mode d‘emploi, ainsi
que des règles et directives principales, est une utilisation cor-
recte. En cas de toute autre utilisation, le fabricant décline toute
responsabilité pour les dommages en résultant!
Groupes de patients cibles: adultes, enfants et nourrissons.
Les produits ne doivent être utilis que par du personnel spéci-
alisé autorisé!
16
3. Règles de sécurité/contre-indications
Pour éviter toute blessure, n‘utilisez pas le sthoscope sans
embouts auriculaires! Si le caoutchouc est endommagé ou
s‘est détaché, les embouts auriculaires doivent être
remplacés avant la prochaine utilisation.
Les embouts auriculaires rotatifs sont munis d‘un couvercle
en caoutchouc. Assurez-vous toujours qu‘il soit bien en place
avant l´utilisation.
N‘appliquez pas le sthoscope à l‘eau.
Un son fort peut interférer avec la perception des souffles.
Ne stérilisez pas le sthoscope dans un autoclave.
Gardez le sthoscope à l‘écart de la chaleur, des solvants et
des huiles.
Vérifiez que le stéthoscope fonctionne correctement avant
chaque utilisation. N‘utilisez pas le produit si vous constatez
qu‘il est endommagé.
Seuls les accessoires et pièces de rechange d‘origine KaWe
peuvent être utilisés.
4. Utilisation
L‘auscultation à l‘aide d‘un sthoscope se base sur le principe
de la „colonne d‘air oscillante“. Pour qu‘un son puisse être émis,
une colonne d‘air fere doit se former.
Lors le sthoscope est utilisé avec les lyres, il faut règler les
tuyaux flexibles de manière à ce que les embouts auriculaires
donnent un peu vers l‘avant vers le nez de la personne à
examiner; cela garantit que les embouts sont parfaitement
placés selon l‘anatomie du conduit auditif.
Posez la membrane ou le récepteur de son sur la partie du
corps à examiner. Les modèles suivants ont une fonction
double membrane/récepteur de son:
- Planet & Planet Air
- Prestige & Prestige light
- Double
- Rapport
- Professionnel Cardiologie
- KaWe COLORSCOP Duo
- Stéthoscope double pour la formation des infirmières
En tournant la tête du sthoscope il est possible de choisir
entre le récepteur de son ou la membrane. Si la membrane
est ouverte, le récepteur de son se ferme et vice versa.
Les sthoscopes à tête à membrane sont utilisés soit pour
l‘auscultation de sites anatomiquement non plans et/ou dans
les cas où les basses fréquences du signal d‘auscultation sont
peu ou pas importantes pour le diagnostic.
Le récepteur de son sur la partie thoracique est utilisé pour
les diagnostics à basse fréquence. En particulier, cela est
cessaire pour l‘auscultation cardiologique. Les bords du
récepteur de son doivent s‘appliquer hermétiquement à
toute la partie du corps examinée!
5. Préparation à l‘utilisation
Vérifiez que le stéthoscope n‘est pas endommagé et
contaminé (en particulier la membrane, les tuyaux et la lyre).
Le système doit être fermé.
Vérifiez le bon positionnement des embouts auriculaires.
Effectuez un réglage individuel de la lyre.
Une fois le test terminé avec succès et aps une préparation
hygiénique appropriée, le stéthoscope peut être utilisé pour
examiner les patients.
6. Préparation hygiénique
Il est recommandé de nettoyer et de désinfecter pério-
diquement le stéthoscope pour éviter toute contamination cro-
isée.
Nettoyage et désinfection
Après l‘examination de chaque patient, le stéthoscope doit être
nettoyé et désinfecté avec une solution d‘alcool à 70% (par ex-
emple, avec un tissu imbi). Dans ce cas, la durée d‘exposition
de l‘agent utilisé doit être prise en compte!
De plus, les composants individuels du stéthoscope doivent être
gulièrement nettoyés à fond. Utilisez une solution d‘alcool à
70% ou une solution de savon douce pour cela. Les embouts et
la membrane peuvent être retirés pour un nettoyage à fond.
Pour ce faire, retirez la bague de retenue correspondante de la
membrane. Manipulez la membrane avec soin pour éviter tout
endommagement! Remontez les composants du stéthoscope
uniquement après qu‘ils soient complètement secs. Le nettoya-
ge automatique n‘est pas autorisé!
Stérilisation
Les sthoscopes ne conviennent pas aux pros de
stérilisation!
Tourner à gauche ou à droite
pour les moles Planet & Planet Air
(point rouge = membrane ouverte)
Rotation de 180°
tous les autres modèles à double tête
pour les modèles Prestige & Prestige
light (symbole d‘oreille = côté ouvert)
17
7. Stockage et transport
Les sthoscopes doivent être stockés et transportés à l‘abri de
la poussière, de l‘humidité et des infections.
Température de l‘environnement
Température ambiante.
Ne l‘exposez pas à une chaleur ou un froid extrême.
Stockage
Conservez le stéthoscope dans un récipient séparé (par exemp-
le, dans un sac en plastique standard). Le sac doit être assez
grand pour conserver l‘instrument pour évites les pliages aps
la fermeture du sac.
8. Maintenance et service
La fi n de la durée de vie utile est généralement déterminée par
l‘usure. Les pces endommagées doivent être tres et rem-
placées immédiatement. Pour les réparations, contactez votre
revendeur spécialisé.
9. Accessoires et pièces de rechange
Vous pouvez trouver les accessoires et les pces de rechange à
l‘adresse suivante:
https://www.kawemed.com/download/broschueren/, ils
peuvent être achetés également chez le revendeur spécialisé.
10. Élimination
Le produit doit être éliminé conformément aux réglementations
environnementales locales..
Élimination avec les déchets ménagers
Informations pour les utilisateurs et les
patients
Tout incident grave impliquant le produit doit être
signalé immédiatement au fabricant et aux auto-
ris compétentes de l‘État membre dans lequel
se trouve l‘utilisateur et/ou le patient.
11. Annexe
Garanties
Avec un usage correct et le respect des règles énoncées dans ce
mode d‘emploi, ainsi que l‘utilisation de pièces de rechange
d‘origine KaWe, la période de garantie légale de deux ans à
compter de la date de vente est en vigueur. Pour toute autre
question et si des réparations sont nécessaires, contactez votre
revendeur spécialisé.
Coordonnées
Contactez votre revendeur spécialisé ou directement le
fabricant (voir au dos pour l‘adresse).
IUD-ID de base
4030155KaWe06SU
Rotation de 180°
tous les autres modèles à double tête
pour les modèles Prestige & Prestige
light (symbole d‘oreille = côté ouvert)
18
Indice
1. Simboli nel manuale d‘uso e sulla confezione ................................................................................................................19
2. Applicazione e destinazione d‘uso.........................................................................................................................................19
3. Norme di sicurezza/controindicazion ........................................................................................................................................ 20
4. Utilizzo ....................................................................................................................................................................................................20
5. Preparazione all’uso .......................................................................................................................................................................20
6. Preparazione igienica ....................................................................................................................................................................20
Pulizia e disinfezione..................................................................................................................................................................................20
Sterilizzazione ............................................................................................................................................................................................20
7. Stoccaggio e trasporto ..................................................................................................................................................................21
Temperatura dell’ambiente .......................................................................................................................................................................21
Stoccaggio ..................................................................................................................................................................................................21
8. Manutenzione e assistenza ........................................................................................................................................................21
9. Attrezzi e parti di ricambio ......................................................................................................................................................... 21
10. Smaltimento........................................................................................................................................................................................21
11. Allegato ..................................................................................................................................................................................................21
Garanzie ......................................................................................................................................................................................................21
Contatti .......................................................................................................................................................................................................21
Bild
fehlt noch
19
Ringraziamo i nostri stimati clienti per aver scelto di acquistare i
prodotti KaWe. I nostri stetoscopi si distinguono per l’alta qua-
lità e lunga durata. La nostra produzione soddisfa i requisiti del
Regolamento (UE) 2017/745 (Regolamento europeo sui dispo-
sitivi medici) ed in base lo stesso Regolamento sono classifi cati
come dispositivi medici di classe I.
Leggere attentamente queste istruzioni per l‘uso, se-
guire rigorosamente le disposizioni e conservare per
riferimento futuro, in caso di necessi.
Prima di utilizzare il prodotto, consultare attentamente le regole
del suo funzionamento, in particolare, i requisiti per la cura.
In caso di domande, contattare il servizio di assistenza (l‘indiriz-
zo del produttore è indicato sul retro).
Le immagini dei diversi modelli di stetoscopi sono mostrate
sulle pagine 4-5 di questo manuale d’uso. Le varietà di colore
sono elencati nel catalogo generale della nostra azienda all’in-
dirizzo https://www.kawemed.com/download/broschueren/,
si possono consultare anche in un punto di vendita specializza-
to.
1. Simboli nel manuale d‘uso e sulla confezione
2.
Attenzione
Tenere in considerazione i requisiti del manuale
d’uso
Numero articolo
Numero del lotto del produttore
Matricola
Produttore
Marchio CE
Certifi cazione per GOST-R per esportazione in Russia
Non contiene lattice
Smaltimento come rifi uto domestico
Conservare in un luogo asciutto
Dispositivi medici
Applicazione e destinazione d‘uso
Lo stetoscopio è uno strumento diagnostico e consiste in una
diramazione per la testa, un tubo cavo e una placca toracica.
Viene utilizzato per l‘auscultazione (ascolto) di suoni/rumori
cardiaci, soffi polmonari e altri parametri udibili. A seconda del
tipo di esame, lo stetoscopio viene applicato sull‘area appropri-
ata del corpo e utilizzato con una leggera pressione. Sugli ste-
toscopi bilaterali è possibile scegliere uno o un altro canale di
ingresso (campana o membrana).
Il rispetto di tutte le istruzioni contenute in questo manuale
d’uso, nonché le principali regole e direttive è la destinazione
d’uso previsto. In caso di qualsiasi altro utilizzo, il produttore
non si assume alcuna responsabilità per eventuali danni!
Gruppi target di pazienti: adulti, bambini e neonati.
I prodotti devono essere utilizzati solo da personale specializza-
to autorizzato!
20
3. Norme di sicurezza/controindicazioni
Per evitare lesioni, non utilizzare uno stetoscopio senza le
olivette! Se la gomma è danneggiata o allentata, l‘olivetta
deve essere sostituita prima del successivo utilizzo.
Le olivette girevoli sono dotate di custodia in gomma.
Controllare sempre l’inserimento corretto delle olivette
prima dell‘uso.
Vietato toccare l’acqua con lo stetoscopio.
Il suono forte può interferire con la percezione del rumore.
Vietato sterilizzare nell’autoclave.
Tenere lo stetoscopio lontano da fonti di calore, solventi e oli.
Prima di ogni utilizzo verificare il corretto funzionamento
dello stetoscopio. Vietato utilizzare il dispositivo in presenza
di qualsiasi danno.
Possono essere utilizzati solo ricambi e accessori originali
KaWe.
4. Utilizzo
Il principio basilare dell‘ascolto attraverso uno stetoscopio è la
„colonna d‘aria oscillante. Per la trasmissione del suono, è
necessario formare una colonna d‘aria chiusa.
Quando si indossa uno stetoscopio, le olivette vengono
inserite leggermente in avanti, verso il naso dell‘esaminatore,
in modo che la struttura anatomica dell‘orecchio contribuisca
al loro stretto contatto con il canale uditivo.
Applicare la membrana o la campana sul punto da
esaminare. I seguenti modelli hanno la doppia funzione di
membrana/campana:
- Planet & Planet Air
- Prestige & Prestige light
- Double
- Rapport
- Per cardiologi professionali
- KaWe COLORSCOP Duo
- Stetoscopio doppio per la preparazione di infermiere
Con un doppio movimento della testa dello stetoscopio è
possibile selezionare una campana o una membrana. Se è
aperta la membrana, la campana si chiude, è viceversa.
Gli stetoscopi con testa a membrana sono utilizzati per
l‘auscultazione di parti anatomicamente non piani e/o nei
casi in cui gli intervalli di bassa frequenza del segnale di
auscultazione sono di scarsa o nessuna importanza per la
diagnosi.
La campana sul torace viene utilizzata per la diagnostica a
bassa frequenza. In particolare, questo è necessario per
l‘auscultazione cardiaca. I bordi della campana devono
aderire ermeticamente alla parte del corpo da esaminare!
5. Preparazione all’uso
Controllare lo stetoscopio per la presenza di danni e sporcizia
(soprattutto la membrana, i tubi flessibili e le olivette). I
sistema deve essere chiuso.
Controllare l’inserimento corretto delle olivette.
Eseguire la regolazione personale dell’arcata.
Dopo aver completato con successo il controllo e dopo un‘ade-
guata preparazione igienica, lo stetoscopio può essere utilizzato
per esaminare i pazienti.
6. Preparazione igienica
Si consiglia di pulire e disinfettare periodicamente lo stetosco-
pio per evitare la contaminazione incrociata.
Pulizia e disinfezione
Dopo la visita di ciascun paziente, lo stetoscopio deve essere
pulito e disinfettato con una soluzione alcolica al 70% (ad
esempio, un panno imbevuto). In questo caso, è necessario
tenere conto della durata dell‘esposizione dell‘agente utilizzato!
Inoltre, è necessario eseguire periodicamente un‘accurata puli-
zia dei singoli componenti dello stetoscopio. Utilizzare per que-
sto una soluzione alcolica al 70% o una soluzione di sapone de-
licato. Le olivette e la membrana possono essere rimossi per la
pulizia. Per rimuovere la membrana, togliere la rotella di fissag-
gio. Maneggiare con cura la membrana per evitare danni! Ese-
guire l’assemblaggio dei componenti solo dopo che sono stati
completamente asciutti.
La pulizia automatica non è consentita!
Sterilizzazione
Gli stetoscopi non sono adatti per i processi di sterilizzazione!
Girare a sinistra o a destra
per modelli Planet & Planet Air
(punto rosso = membrana aperta)
Girare a 18
tutti gli altri modelli con la testa doppia
per modelli Prestige & Prestige light
(simbolo con l’immagine dell’orecchio
= lato aperto)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

KaWe QM-1-025O Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per