Corsair iCUE H100i Series Manuale utente

Categoria
Componenti di raffreddamento del computer
Tipo
Manuale utente
iCUE
H100i | H115i | H150i | H170i
ELITE CAPELLIX XT
EXTREME PERFORMANCE LIQUID CPU COOLER
ENGLISH
EN
FRANÇAIS (EURO)
FR
DEUTSCH
DE
NEDERLANDS
NL
ITALIANO
IT
ESPAÑOL (EURO)
ES
PORTUGUÊS (EURO)
PT
POLSKI
PL
简体中文
SC

AR
ENGLISH
TABLE OF CONTENTS
NOTE: Most newer PC cases include a CPU cut-out to allow access to the bottom of the motherboard.
If your case does not include a cut-out, you will need to remove your motherboard from the case prior
to installation. ELITE Series coolers come with the Intel mounting bracket pre-installed on the pump for
quick installation.
INTEL (All Sockets)
AMD AM5/AM4
AMD sTRX4
FINISHING UP YOUR INSTALLATION
FAQ
1
ENGLISH
INTEL
ELITE CAPELLIX
1
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
B CA
D E F
G
H
I
LK
J
N O
M
QP
INCLUDED HARDWARE
Highlighted parts for Intel installation only
x4 INTEL 1200/1156/1155/1151/1150
STANDOFFS x4 INTEL 2066/2011-3/2011 STANDOFFS x4 INTEL 1700 STANDOFFS
x1 INTEL BACKPLATE
(1200/115X/1700 ONLY) x1 INTEL MOUNTING BRACKET
(PRE-INSTALLED) x4 THUMB NUTS
x4 AMD AM5/AM4 STANDOFFS x1 AMD AM5/AM4 MOUNTING BRACKET x1 AMD sTR4/sTRX4
MOUNTING BRACKET
x4 AMD sTR4/sTRX4 STANDOFFS x16 LONG FAN SCREWS (H100i/H115i)
x24 LONG FAN SCREWS (H150i/H170i) x8 RADIATOR SCREWS (H100i/H115i)
x12 RADIATOR SCREWS (H150i/H170i)
x8 WASHERS (H100i/H115i)
x12 WASHERS (H150i/H170i) x2 AF RGB ELITE FANS (H100i/H115i)
x3 AF RGB ELITE FANS (H150i/H170i) COMMANDER CORE
CAP REMOVAL TOOL x2 ALTERNATIVE PUMP CAP
2
D
CLGA 1700
BLGA 2011/
2011-3/2066
ALGA 1200/
1150/1151/
1155/1156
ENGLISH
> Attach the provided Intel standoff for
your socket.
> Use (A) for LGA 1200/115X, (B) for
LGA 2011/2011-3/2066 or (C) for LGA 1700.
> Tighten all four standoffs until
firmly secured.
Adjust backplate for your required socket.
NOTE: Intel LGA 2066/2011-3/2011
do not require backplate installation.
Proceed to step 2.
2. INSTALLING THE INTEL STANDOFF SCREWS
1. INSTALLING THE INTEL BACKPLATE
3
K
N
M
L
F
ENGLISH
Attach the radiator and the fans as shown.
For the best cooling performance, we
recommend mounting the fans as an
air-intake to your PC case.
> Align the bracket and pump over the
standoff screws as shown.
> Attach the thumb nuts (F) to the standoff
screws as shown.
> Tighten the thumb nuts until all four corners
are firmly secured.
4. INSTALLING THE PUMP UNIT
3. INSTALL THE FANS AND RADIATOR
Please continue to Page 10 to continue your installation.
AMD AM5/AM4
ELITE CAPELLIX
1
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
B
C
A
D
E
F
GH
I
LK
J
N O
M
QP
x4 INTEL 1200/1156/1155/1151/1150
STANDOFFS x4 INTEL 2066/2011-3/2011 STANDOFFS x4 INTEL 1700 STANDOFFS
x1 INTEL BACKPLATE
(1200/115X/1700 ONLY) x1 INTEL MOUNTING BRACKET
(PRE-INSTALLED) x4 THUMB NUTS
x4 AMD AM5/AM4 STANDOFFS x1 AMD AM5/AM4 MOUNTING BRACKET x1 AMD sTR4/sTRX4
MOUNTING BRACKET
x4 AMD sTR4/sTRX4 STANDOFFS x16 LONG FAN SCREWS (H100i/H115i)
x24 LONG FAN SCREWS (H150i/H170i) x8 RADIATOR SCREWS (H100i/H115i)
x12 RADIATOR SCREWS (H150i/H170i)
x8 WASHERS (H100i/H115i)
x12 WASHERS (H150i/H170i) x2 AF RGB ELITE FANS (H100i/H115i)
x3 AF RGB ELITE FANS (H150i/H170i) COMMANDER CORE
CAP REMOVAL TOOL x2 ALTERNATIVE PUMP CAP
INCLUDED HARDWARE
Highlighted parts for AMD AM5/AM4 installation only
ENGLISH
5
K
N
M
L
Figure 1 Figure 2
E H
Figure 1 Figure 2
ENGLISH
> Remove the integrated Intel mounting
bracket (Figure 1).
> Install the AMD AM5/AM4 bracket by
pushing both sides into the slot on the
pump until secure (Figure 2).
NOTE: It is important that the AMD AM5/
AM4 retention bracket be evenly secured on
all sides before installation.
Attach the radiator and the fans as shown.
For the best cooling performance, we
recommend mounting the fans as an
air-intake to your PC case.
2. INSTALL THE FANS AND RADIATOR
Remove the existing AMD AM5/AM4
mounting brackets shown.
3. PREPARE THE MOTHERBOARD FOR INSTALLATION
1. INSTALLING THE AMD AM5/AM4 MOUNTING BRACKET
6
G
FAlign the bracket with the AMD AM5/AM4
standoffs as shown. Tighten the thumb
nuts (F) until secure.
> Attach the provided AMD AM5/AM4
standoffs to the CPU socket.
> Tighten all four screws until firmly secure.
5. INSTALLING THE PUMP UNIT
4. INSTALLING THE AMD AM5/AM4 STANDOFF SCREWS
ENGLISH
Please continue to Page 10 to continue your installation.
7
ENGLISH
AMD sTRX4
ELITE CAPELLIX
1
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
B
C
A
D
E
F
G
H
I
LK
J
N O
M
QP
INCLUDED HARDWARE
Highlighted parts for AMD sTRX4 installation only
x4 INTEL 1200/1156/1155/1151/1150
STANDOFFS x4 INTEL 2066/2011-3/2011 STANDOFFS x4 INTEL 1700 STANDOFFS
x1 INTEL BACKPLATE
(1200/115X/1700 ONLY) x1 INTEL MOUNTING BRACKET
(PRE-INSTALLED) x4 THUMB NUTS
x4 AMD AM5/AM4 STANDOFFS x1 AMD AM5/AM4 MOUNTING BRACKET x1 AMD sTR4/sTRX4
MOUNTING BRACKET
x4 AMD sTR4/sTRX4 STANDOFFS x16 LONG FAN SCREWS (H100i/H115i)
x24 LONG FAN SCREWS (H150i/H170i) x8 RADIATOR SCREWS (H100i/H115i)
x12 RADIATOR SCREWS (H150i/H170i)
x8 WASHERS (H100i/H115i)
x12 WASHERS (H150i/H170i) x2 AF RGB ELITE FANS (H100i/H115i)
x3 AF RGB ELITE FANS (H150i/H170i) COMMANDER CORE
CAP REMOVAL TOOL x2 ALTERNATIVE PUMP CAP
8
J
Figure 1 Figure 2
E I
ENGLISH
> Attach the provided AMD sTRX4 standoffs
to the CPU socket.
> Tighten all four standoff screws until
firmly secure.
> Remove the integrated Intel mounting
bracket (Figure 1).
> Install the AMD sTRX4 bracket by pushing
both sides into the slot on the pump until
secure (Figure 2).
NOTE: It is important that the AMD sTRX4
retention bracket be evenly secured on all
sides before installation.
2. INSTALLING THE AMD sTRX4 STANDOFF SCREWS
1. INSTALLING THE AMD sTRX4 MOUNTING BRACKET
9
K
N
L
M
ELITE CAPELLIX
13
F
ENGLISH
> Align the bracket and pump over the
standoff screws as shown.
> Attach the thumb nuts (F) to the standoff
screws as shown.
> Tighten the thumb nuts until all four corners
are firmly secured.
Attach the radiator and the fans as shown.
For the best cooling performance,
we recommend mounting the fans as
an air-intake to your PC case.
4. INSTALLING THE PUMP UNIT
3. INSTALL THE FANS AND RADIATOR
Please continue to Page 10 to continue your installation.
10
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
3-PIN
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
Figure 1 Figure 2 Figure 3
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
ENGLISH
CONNECT COMMANDER CORE TO USB 2.0 HEADER AND POWER
CONNECT FANS AND PUMP TO iCUE COMMANDER CORE
> Connect pump 24-pin cable to your Commander CORE (Figure 1).
> Connect pump tach cable to the CPU_FAN header on your motherboard (Figure 2).
> Connect each fan to the Commander CORE (Figure 3).
> Connect each fan RGB lead to the Commander CORE (Figure 3).
> Using the attached USB cable, connect the Commander CORE to a motherboard
USB 2.0 header.
> Connect pump power cable to an available SATA power plug from your power supply.
11
ENGLISH
FAQ
1. How do I know the direction of the airflow of the fan?
An arrow located on the side of the fan indicates the direction of airflow.
2. Can I reuse the pre-applied thermal paste on the cooler for re-installation?
Re-installation of the cooler will require you to clean off the pre-applied thermal paste and re-apply the
XTM70 thermal paste (sold separately).
3. What orientation should I install my radiator?
The best way to install a radiator is with the tubes on the bottom of the case, though you can install
it with the tubes in any position, including an inverted radiator, as long as the highest point in the
radiator is visibly higher than the CPU pump.
4. My cooler and fans are blinking red or not functioning. What do I do?
Please double check all connections between the cooler and fans. Ensure that the cooler is updated
to the most recent firmware via iCUE. If this does not resolve your problems, please open a support
ticket at support.corsair.com or contact our customer support team for further troubleshooting
and assistance.
https://help.corsair.com/hc/en-us/requests/new
5. What should I do if my cooler backplate feels loose after installation?
It is common for your cooler backplate to feel loose after you install it into your motherboard for the
first time. Once you have seated and tightened down the cooler pump, it will pull the backplate to the
motherboard and apply pressure on the socket via the cooler.
IMPORTANT: Do NOT, under any circumstances, add additional washers and spacers to your
backplate to decrease play in the backplate. Doing so will increase the mounting pressure to the
retention kit and potentially damage your retention kit, motherboard, or socket.
FRANÇAIS
TABLE DES MATIÈRES
REMARQUE: La plupart des nouveaux boîtiers de PC comportent un accès facilité au processeur qui
permet d’accéder à la base de la carte mère. Si aucun accès n’est prévu sur votre boîtier, vous devrez
retirer votre carte mère du boîtier avant de procéder à l’installation. Les refroidisseurs ELITE Series sont
fournis avec le support de fixation Intel préinstallé sur la pompe afin de permettre une installation rapide.
INTEL (Tous Les Sockets)
AMD AM5/AM4
AMD sTRX4
ACHÈVEMENT DE VOTRE INSTALLATION
FOIRE AUX QUESTIONS
1
INTEL
FRANÇAIS
ELITE CAPELLIX
1
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
B CA
D E F
G
H
I
LK
J
N O
M
QP
Les sections en surbrillance concernent uniquement linstallation Intel
MATÉRIEL INCLUS
x4 ENTRETOISES INTEL
1200/1156/1155/1151/1150 x4 ENTRETOISES INTEL 2066/2011-3/2011 x4 ENTRETOISES INTEL 1700
x1 PLAQUE ARRIÈRE INTEL
(UNIQUEMENT 1200/115X/1700) x1 SUPPORT DE FIXATION INTEL
(PRÉINSTALLÉ) x4 ÉCROUS À SERRAGE À MAIN
x4 ENTRETOISES AMD AM5/AM4 x1 SUPPORT DE FIXATION AMD AM5/AM4 x1 SUPPORT DE FIXATION AMD sTR4/sTRX4
x4 ENTRETOISES AMD sTR4/sTRX4 x16 VIS DE VENTILATEUR LONGUES (H100i/H115i)
x24 VIS DE VENTILATEUR LONGUES (H150i/H170i) x8 VIS DE RADIATEUR (H100i/H115i)
x12 VIS DE RADIATEUR (H150i/H170i)
x8 RONDELLES (H100i/H115i)
x12 RONDELLES (H150i/H170i) x2 VENTILATEURS AF RGB ELITE (H100i/H115i)
x3 VENTILATEURS AF RGB ELITE (H150i/H170i) COMMANDER CORE
OUTIL DE RETRAIT DU CAPUCHON x2 CAPUCHONS ALTERNATIFS DE POMPE
2
D
CLGA 1700
BLGA 2011/
2011-3/2066
ALGA 1200/
1150/1151/
1155/1156
> Attachez les entretoises Intel fournies pour
votre prise.
> Utilisez (A) pour le modèle LGA 1200/115X,
(B) pour LGA 2011/2011-3/2066 ou (C) pour
LGA 1700.
> Serrez les quatre vis jusqu’à ce quelle
soient solidement fixées.
2. INSTALLATION DES VIS D’ENTRETOISE INTEL
Ajustez la plaque arrière pour votre socket.
REMARQUE: LGA 2066/2011-3/2011
ne nécessitent pas l’installation d’une
plaque arrière.
Passez à l’étape 2.
1. INSTALLATION DE LA PLAQUE ARRIÈRE INTEL
FRANÇAIS
3
K
N
M
L
F
Veuillez passer à la page 10 pour procéder à la suite de linstallation.
> Alignez le support et la pompe avec les vis
à entretoise comme indiqué.
> Attachez les écrous à serrage à main (F)
sur les vis à entretoise comme indiqué.
> Serrez les écrous à serrage à main
jusqu’à ce que les quatre coins soient
solidement fixés.
4. INSTALLATION DE LA POMPE
Attachez le radiateur et les ventilateurs,
comme illustré. Pour des performances
de refroidissement optimales, nous vous
recommandons dinstaller les ventilateurs
comme une entrée d’air sur la tour
de votre ordinateur.
3. INSTALLATION DES VENTILATEURS ET DU RADIATEUR
FRANÇAIS
AMD AM5/AM4
ELITE CAPELLIX
1
65 4 3 2 1
65 4 3 2 1
RGB HUB
FANS
B
C
A
D
E
F
GH
I
LK
J
N O
M
QP
Les sections en surbrillance concernent uniquement linstallation AMD AM5/AM4
MATÉRIEL INCLUS
FRANÇAIS
x4 ENTRETOISES INTEL
1200/1156/1155/1151/1150 x4 ENTRETOISES INTEL 2066/2011-3/2011 x4 ENTRETOISES INTEL 1700
x1 PLAQUE ARRIÈRE INTEL
(UNIQUEMENT 1200/115X/1700) x1 SUPPORT DE FIXATION INTEL
(PRÉINSTALLÉ) x4 ÉCROUS À SERRAGE À MAIN
x4 ENTRETOISES AMD AM5/AM4 x1 SUPPORT DE FIXATION AMD AM5/AM4 x1 SUPPORT DE FIXATION AMD sTR4/sTRX4
x4 ENTRETOISES AMD sTR4/sTRX4 x16 VIS DE VENTILATEUR LONGUES (H100i/H115i)
x24 VIS DE VENTILATEUR LONGUES (H150i/H170i) x8 VIS DE RADIATEUR (H100i/H115i)
x12 VIS DE RADIATEUR (H150i/H170i)
x8 RONDELLES (H100i/H115i)
x12 RONDELLES (H150i/H170i) x2 VENTILATEURS AF RGB ELITE (H100i/H115i)
x3 VENTILATEURS AF RGB ELITE (H150i/H170i) COMMANDER CORE
OUTIL DE RETRAIT DU CAPUCHON x2 CAPUCHONS ALTERNATIFS DE POMPE
5
K
N
M
L
Figure 1 Figure 2
E H
Figure 1 Figure 2
Retirez les supports de fixation
AMD AM5/AM4 existants indiqués.
3. PRÉPARATION DE LA CARTE MÈRE POUR L’INSTALLATION
Attachez le radiateur et les ventilateurs,
comme illustré. Pour des performances
de refroidissement optimales, nous vous
recommandons dinstaller les ventilateurs
comme une entrée d’air sur la tour
de votre ordinateur.
2. INSTALLATION DES VENTILATEURS ET DU RADIATEUR
> Pour retirer le support de fixation Intel
intégré (Figure 1).
> Installez le support AMD AM5/AM4 en
appuyant des deux côtés dans le logement
sur la pompe jusqu’à ce qu’il soit en place
(Figure 2).
REMARQUE: Il est important que le support
de retenue AMD AM5/AM4 soit bien
en place des deux côtés avant de procéder
à l’installation.
1. INSTALLATION DU SUPPORT DE FIXATION AMD AM5/AM4
FRANÇAIS
6
G
F
Veuillez passer à la page 10 pour procéder à la suite de linstallation.
Alignez le support avec les entretoises
AMD AM5/AM4 comme indiqué.
Serrez complètement les écrous à serrage
à main (F).
5. INSTALLATION DE LA POMPE
> Placez les entretoises AMD AM5/AM4
fournies dans le socket de processeur.
> Serrez les quatre vis jusqu’à ce quelle
soient solidement fixées.
4. INSTALLATION DES VIS D’ENTRETOISE AMD AM5/AM4
FRANÇAIS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122

Corsair iCUE H100i Series Manuale utente

Categoria
Componenti di raffreddamento del computer
Tipo
Manuale utente