Sentiotec ALASKA MINI Manuale utente

  • Ciao! Ho letto le istruzioni di montaggio e d’uso della sauna ALASKA MINI. Questa guida contiene istruzioni dettagliate per l'installazione, l'uso e la manutenzione della tua sauna in legno massello. Sono pronto a rispondere a qualsiasi domanda specifica tu possa avere, ad esempio riguardo l’assemblaggio, la pulizia o altri aspetti trattati nel documento.
  • Cosa fare in caso di pezzi mancanti?
    Cosa fare in caso di fuoriuscita di resina?
    Come pulire la sauna?
ALASKA-MN
Version 05/22 Ident. no. 1-030-270
INSTRUCTIONS FOR INSTALLATION AND USE
English EN
DE
FR
IT
PL
PT
Solid wood sauna
ALASKA
MINI
160 x 110 x 204 cm
Table of Contents
1. Preparing for installation 3
1.1. Important note: 3
1.2. Tools required 4
1.3. Maintenance and cleaning 5
1.4. Disposal 5
1.5. Warranty 5
1.6. ALASKA MINI parts list 7
2. Cabin installation 9
2.1. Base frame installation 9
2.2. Wall element installation 10
2.3. Ceiling installation 17
2.4. Ventilation slit installation 19
2.5. Installinginteriorttings 19
2.6. Installing accessories 25
2.7. Installing glass door 27
2.8. Installing roof trim 29
2.9. Installing ceiling cover slat 30
3. Floor plan 31
3.1. Rightoorplan 31
3.2. Leftoorplan 32
3.3. Changestotheleftoorplaninstallation 33
EN
Instructions for installation and use p. 3/34
1. Preparing for installation
Read these installation instructions carefully and keep them within reach when
using the sauna, so that you can look up product information at any time.
Attention!
The electrical connection may only be performed by a qualied electrician
or similarly trained person.
These installation instructions can also be found in the downloads section
of our website: www.sentiotec.com/downloads.
1.1. Important note:
Before you begin work, check the parts list to ensure that all the individual
parts have been delivered. If you discover any missing parts, notify your
dealer within 14 days of receiving the sauna cabin.
The room that the sauna is installed in must be dry and ensure an appropriate
amount of air circulation.
● Theoormustbelevelandeven,preferablyastoneortiledoor.
A minimum room height of 230 cm is required for the cabin installation work.
A distance of at least 5 cm from the wall must be maintained.
The inside of the wooden parts used must not be treated with any impreg-
nating material.
You need an assistant for the installation.
Wood is a natural product that can swell, shrink or warp, despite good stor-
age. For this reason, some force may be necessary during the installation.
● Allscrewttingsmustbepre-drilled.
Instructions for installation and use p. 4/34
This symbol indicates tips and useful information
Pre-drill
Cut to real measurement with backsaw
Check the right angle:
1.2. Tools required
Hammer with a wooden head or a mallet
Cordless screwdriver with bits for cross-head screws and Torx
Roller tape measure
Drill bits with a diameter of 3 mm, 10 mm, 20 - 30 mm
(for sauna heater power cable)
Spirit level
1.5 mm hexagonal socket wrench
Utility knife
Ladder
Backsaw
60 cm
80 cm
100 cm
Handle glass with care: Special care must be taken with the edges of
the glass – hardened glass can shatter into small pieces in the event of
impact. Insert protective cushioning (e.g: cardboard box) under the edge
of the glass.
EN
Instructions for installation and use p. 5/34
1.3. Maintenance and cleaning
The sauna should be cleaned with a damp cloth. Only use warm water – no
cleaning products.
We recommend heating the cabin once a month if the sauna is not used for
a long time.
1.4. Disposal
Please dispose of packaging materials in accordance with the
applicable disposal regulations.
Used appliances contain reusable materials as well as hazardous
substances. Therefore, do not dispose of your used appliance with
household waste, but rather do so in accordance with the locally
applicable regulations.
1.5. Warranty
Weprovideave-yearwarrantyonallofoursolidwoodandelementcabinsof
the line sentiotec sauna and sentiotec infra for private usage. For commercial
usage, the warranty is two years. For cabins of the hotline series, the warranty
is two years.
Requirement for this warranty:
The corresponding invoice is presented,
a detailed description of the defect is enclosed,
the cabins were installed in accordance with the sentiotec installation and
operating instructions,
the warranty claim is received by sentiotec within the warranty period.
Instructions for installation and use p. 6/34
Excluded from the warranty are:
Decienciesordamagethatiscausedbynon-intendeduse
Cabinsthatweremodiedwithouttheexplicitapprovalofthemanufacturer
Pitch pockets
Pitch leaking out
Damage and discolouration of the wood due to inadequate ventilation or
a non-intended installation site
Natural changes in the wood such as discolouration, crack formation, shrink-
age, swelling or similar changes due to the natural properties of the wood
Pitch pockets are not grounds for return, since they can always appear in spruce
wood and the depth at which they lie cannot be detected during the sorting out
process. If these are just under the surface, heat can cause them to soften and
“bleed”. Remove leaking pitch with a rag soaked in acetone. If only droplets of
pitch occur, allow these to harden and then carefully scrape them off with a knife.
The warranty period starts from the date of invoice of the cabin manufacturer.
A requirement is the presentation of the original invoice. If no original invoice
is available, the month of manufacture, noted on the nameplate of the product,
is used as the basis for the start of the warranty period. The warranty period is
neither extended nor renewed by warranty services.
Theve-yearwarrantyisanadditiontothetermsandconditionsofsentiotec
GmbH.
EN
Instructions for installation and use p. 7/34
Base frame
1 Base frame 156 x 9 x 4 cm
1 Base frame 108 x 9 x 4 cm
1 Base frame 102 x 9 x 4 cm
1 Base frame 64 x 9 x 4 cm
Wall elements
1 A/B ventilation element with Multiclip 193 x 48 x 4 cm
1 A/B wall element 193 x 48 x 4 cm
1 A/B wall element with Multiclip 193 x 48 x 4 cm
4 A/A wall elements with Multiclip 193 x 48 x 4 cm
1 A/A electrical element with Multiclip 193 x 58 x 4 cm
1Elementabovedoor,oorplan(right) 81.5 x 10.1 x 4 cm
1Elementabovedoor,oorplan(left) 81.5 x 10.1 x 4 cm
Ceiling elements
2 Ceiling elements 146 x 49 x 4 cm
Corner posts
3 90° corner posts with Multiclip 193 x 6 x 6 cm
1
Corner post with front hinge for glass door with Multiclip
202 x 6 x 7.5 cm
1 Post for glass element, 8 mm groove 202 x 4.5 x 4 cm
Support slats
2 Roof support slats 140 x 4 x 4 cm
2 Roof support slats 100 x 4 x 4 cm
2 Roof cover slats 144 x 1.2 x 4 cm
2 Roof cover slats 104 x 1.2 x 4 cm
2 Bench support slats 58 x 4 x 4 cm
2 Mounting slats for bench screen 26 x 4 x 4 cm
No. of items Name Dimensions
1.6. ALASKA MINI parts list
Instructions for installation and use p. 8/34
No. of items Name Dimensions
Interior ttings
1 Bench 147 x 62 x 9 cm
1 Foot step panel 80 x 35 x 9 cm
2 Foot step feet 43 x 33 x 4 cm
2 Foot step struts, 2 x 45° diagonal 49.5 x 8 x 2 cm
1 Backrests 138 x 26 x 4 cm
1 Bench screen 147 x 35 x 4 cm
1 Heater protection grille – lime wood 62.5 x 8 x 2 cm
1 Heater protection grille – lime wood 37.5 x 8 x 2 cm
3
Mounting slats for heater protection grille – spruce
7 x 2.5 x 2.5 cm
1 Headrest 43 x 25 x 7 cm
1 Lamp protection grille 38 x 32 x 4 cm
1 Ventilation slit 52 x 14 x 1.5 cm
Glass elements
1 Glass door
191.5 x 59 x 0.8 cm
1 Glass element
194.5 x 22.4 x 0.8
cm
Roof rim slats
1 Roof rim slat 160 x 6 x 4 cm
2 Roof rim slats 115 x 6 x 4 cm
Accessories
1Ualuminiumprole
21.1 x 1.2 x 1.5 cm
1 Door handle set wood/stainless steel
1 2 door hinges 8653-02
1 Door magnet, sleeve plate
1 Sauna lamp
1 Template for Multiclip installation
1 3 Silicon cables: 5 x 2.5 mm²
1 3 Silicon cables: 3 x 1.5 mm²
1 Installation material set
1 Installation instructions
EN
Instructions for installation and use p. 9/34
2. Cabin installation
Thecabincanhavearightorleftsetup,pleasenotethecorrespondingoor
plans on Page 31 and Page 32.
2.1. Base frame installation
Right oor plan
Left oor plan
156 cm
64 cm
102 cm
108 cm
102 cm
108 cm
156 cm
64 cm
3 mm drill bit, 3 screws 4 x 70 mm
Instructions for installation and use p. 10/34
2.2. Wall element installation
The corner posts are connected to the wall elements using Multiclips. The other
wall elements are connected by tongue and groove and are screwed together.
Right oor plan
*
*
* *
*
*
* Multiclips
Attention!
Theinstallationsubsequentlydescribedisfortherightoorplan.
ForchangesaffectinginstallationfortheleftoorplanseePage33.
* *
A always refers to the visible side. This is labelled on the top side of
the wall elements.
EN
Instructions for installation and use p. 11/34
Pre-assemblethewallelementswiththecornerpostsontheoorand
then place these posts on the base frame.
Insert the corner post on the wall elements, moving it downwards. When doing
this, ensure that the Multiclips are correctly aligned (see below). The corner post
mustbeushwiththewallelements.
Multiclip
Installing corner posts with wall elements
Instructions for installation and use p. 12/34
Installing wall elements
Electrical element
The electrical element has drill holes for laying cables. For the position,
seeoorplansonPage31andPage32.
EN
Instructions for installation and use p. 13/34
Screwing wall elements together
3 mm drill bit, 4 screws 4 x 70 mm
Check the right angle before screwing the wall elements together.
Observe the tip on page 4.
Instructions for installation and use p. 14/34
Corner post and post for glass
EN
Instructions for installation and use p. 15/34
Glass element
Element above the door
Selecttheelementfortherightoorplan
Instructions for installation and use p. 16/34
3 mm drill bit, 2 screws 4 x 70 mm
EN
Instructions for installation and use p. 17/34
2.3. Ceiling installation
Roof support slats
4 cm
3 mm drill bit, 12 screws 4 x 70 mm
Instructions for installation and use p. 18/34
Ceiling elements
3 mm drill bit, 10 screws 4 x 70 mm
1 cm
1 cm
EN
Instructions for installation and use p. 19/34
2.4. Ventilation slit installation
2.5. Installing interior ttings
Bench support slats
2 screws 4 x 60 mm
3 mm drill bit, 3 screws 5 x 70 mm
3 mm drill bit, 4 screws 3 x 40 mm
82 cm
Instructions for installation and use p. 20/34
3 mm drill bit, 3 screws 5 x 70 mm
Screws 4 x 60 mm
/