Kathrein 20510060 Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

Page 1 of 1
KATHREIN Digital Systems GmbH • Anton-Kathrein-Straße 13 • 83022 Rosenheim • Germany
Rosenheim, 31.03.2019
Information über gesellschaftsrechtliche Änderung
Information about change in corporate legal status
Zum 1. April 2019 geht das Geschäftsfeld „Terrestrial & Satellite Reception“ der
KATHREIN SE (vormals KATHREIN-Werke KG) auf die KATHREIN Digital Systems
GmbH über.
Die neuen Firmendaten lauten ab 01.04.2019 wie folgt:
KATHREIN Digital Systems GmbH
Anton-Kathrein-Str. 13
83022 Rosenheim, Deutschland
Steuer-Nr.: 156/117/31083
UST-Ident-Nr.: DE311049363
Registergericht: Traunstein, HRB 25841
______________________________________________________________________________
As of 1 April 2019, KATHREIN SE’s (formerly KATHREIN-WERKE KG) “Terrestrial &
Satellite Reception” business unit will be transferred to KATHREIN Digital Systems
GmbH (limited liability company).
From 1 April 2019, the new company data are:
KATHREIN Digital Systems GmbH
Anton-Kathrein-Str. 1–3
83022 Rosenheim, Germany
Tax ID No.: 156/117/31083
VAT Reg. No.: DE311049363
Commercial Register: Traunstein, HRB 25841
KATHREIN
Digital Systems GmbH
Anton
-Kathrein-Straße 1–3
83022 Rosenheim
Germany
www.kathrein
-ds.com
info
@kathrein-ds.com
Executive Board
:
Michael Auer
Uwe Thumm
US
t-ID-Nr.: DE 311 049 363
Steuer
-Nr.: 156/117/31083
GLN:
40 63242 00000 5
WEEE
-Reg.-Nr.: DE 66199153
Registered Office: Rosenheim, DE
Commerc
ial Register: Traunstein, HRB 25841
Commerzbank AG
IBAN:
DE24 7114 0041 0611 9002 00
BIC:
COBADEFFXXX
936500001
1 / 8
Kaskadierfähiger Multischalter mit integriertem Modem
zur Verteilung von vier Sat-Ebenen und terrestrischer
Signale auf bis zu acht Receiver
Erstellung eines Heimnetzwerks über die vorhandene
terrestrische Verteilung des Multischalters.
Die IP-Daten stehen an jedem Teilnehmerausgang
zur Verfügung. Dadurch reduziert sich der
Installationsaufwand - es müssen keine neuen
Netzwerkkabel verlegt werden
Integrierte, hochselektive Frequenzweiche für die
IP-Daten
Durch das optimierte Verteilsystem der EXI 3508 sind
Entfernungen von > 700 m für den IP-Frequenzbereich
möglich
Integrierter Verstärker für geringe
Anschlussdämpfungen im Sat-Bereich
Integrierte Preemphase zum Entzerren der
Kabeldämpfung
Empfangsmöglichkeit des terrestrischen Bereiches
auch bei ausgeschaltetem Sat-Receiver
Fernspeisemöglichkeit über den Eingang horizontal
low. Alle anderen Eingänge sind spannungsfrei
(dadurch auch Betrieb mit UAS 585 möglich)
Für die Innenmontage
EXI 3508 20510060
Sat-ZF-Verteilsystem (4 x Sat-ZF)
Multischalter mit integriertem Modem
Merkmale Multischalter
EXI 30 (BN 21110024): Über den SAT-Anschluss
fernspeisbare Steckdose mit optimaler Selektion für
Daten und HF-Signale
Einzelmodem EXI 01 (BN 20510061):
Zur Rückwandlung der IP-Daten an den
Teilnehmersteckdosen (z. B. zum Anschluss eines Sat-
Receivers mit Ethernet-Buchse).
Software EXI 700: Zeigt die sichtbaren Modems eines
Netzwerks an (Download über: www.kathrein.de)
Hochpass EXI 90 (BN 20510062): Werden weitere
Multischalter (nicht aus der EXI-Reihe) kaskadiert
und wird das EXI 01 an einem dieser Multischalter
betrieben, muss der Hochpass auf den terrestrischen
Eingang des Multischalters geschraubt werden.
Dadurch werden in der Kaskade nachfolgende
Multischalter isoliert bzw. die Ein- und Abstrahlung
des IP-Frequenzbereichs von und zur terrestrischen
Antenne verhindert. Im EXI 3508 ist der Hochpass
bereits integriert.
Zubehör
*
)
Quality of Service
**
)
Es können alternativ auch die Steckdosen ESD 84 und ESD 32
verwendet werden
Merkmale integriertes Modem
Modem für das Kathrein-IP über Koax-System „K-LAN“
(auf Basis des Standards IEEE 1901)
Ideal für die Netzwerkanbindung von Receivern, TV-
Geräten und Blu-ray-Playern. Aber auch ein PC und
andere netzwerkfähige Geräte können komfortabel
mit einem Router (z. B. Fritzbox) verbunden werden
> 500-Mbit-Datendurchsatz (Brutto) ermöglichen
mehrere HD-Streams bei gleichzeitiger
Datenübertragung zwischen PC’s. Dank QoS *
)
werden entsprechende Dienste priorisiert.
Störsicher durch hohes Schirmungsmaß
128-Bit-AES-Verschlüsselung. Sichere, private
Netzwerkverbindung durch Tastendruck - keine
Software notwendig
Bereits vorhandene Steckdosen, die den
Frequenzbereich 5-68 MHz unterstützen, können
weiter verwendet werden. Ansonsten empfi ehlt sich
der Einsatz der speziell für K-LAN entwickelten Dose
EXI 30. **
)
Eco Power Mode: Das Modem schaltet automatisch
auf Stand-by und wird durch das Netzwerk wieder
„aufgeweckt“. Verbrauch: 1,0 Watt im Stand-by/
4,2 Watt im Betrieb
2 / 8
Bei größerem Durchmesser
des Kabel-Innenleiters als
1,2 mm bzw. Grat können
die Gerätebuchsen zerstört
werden.
Das integrierte Modem im Multischalter EXI 3508 sowie das Kathrein-Modem EXI 01 sind ab Werk mit einem Netzwerk-
schlüssel gesichert. Zur einfachen Inbetriebnahme zweier Modems müssen diese mit einem Koaxialkabel an der Buch-
se
verbunden werden. Die zu verbindenden Netzwerkgeräte, z. B. Router und Receiver, werden mit dem beige-
legten Ethernet-Kabel an der vorgesehenen RJ 45-Buchse angeschlossen. Die LEDs „Power“ und „Coax/Link“ leuchten.
Die Datenverbindung ist hergestellt. Es können bis zu 64 Modems miteinander verbunden werden.
Zusätzliche Sicherheit:
In einem koaxialen Verteilsystem „sehen“ sich alle angeschlossenen Kathrein-Modems. Möchten Sie ein privates Netz-
werk mit den Ihnen gehörenden Modems bilden, gehen Sie wie folgt vor:
1. Drücken Sie ca. 12 Sekunden auf den Taster „Pairing“. Beide LED erlöschen kurzzeitig. Der Netzwerkschlüssel ist
gelöscht. Die LED „Power“ leuchtet „Coax/Link“ bleibt aus. Führen Sie diesen Schritt bei allen Ihren Geräten, die Sie zu
einem privaten Netzwerk hinzufügen möchten, durch!
Inbetriebnahme des Modems
Montage- und Sicherheitshinweise
Die beschriebenen Geräte dienen ausschließlich der Installation von Satelliten-Empfangsanlagen.
Jegliche anderweitige Nutzung oder die Nichtbeachtung dieses Anwendungshinweises hat den Verlust der
Gewährleistung bzw. Garantie zur Folge.
Die Geräte dürfen nur in trockenen Innenräumen montiert werden. Nicht auf oder an leicht entzündlichen
Materialien montieren.
Die Geräte sind mit einer Potenzial-Ausgleichsleitung (Cu, mindestens 4 mm
2
) zu versehen.
Die Sicherheitsbestimmungen der jeweils aktuellen Normen EN 60728-11 und EN 60065 sind zu beachten.
Befestigungsmittel: Holzschrauben, max Ø: 4 mm
(nicht im Lieferumfang)
Verbindungsstecker: HF-Stecker 75 (Serie F) nach EN 61169-24.
Nicht benutzte HF-Anschlüsse sind mit 75--Widerständen (z. B. EMK 03) abzuschließen.
Stromführendes Gerät
Nicht öffnen oder am Gerät manipulieren!
Bei Arbeiten an der Anlage immer Netzstecker aus der Steckdose ziehen!
Das Gerät ist nur für die Wandmontage vorgesehen! Montieren und betreiben Sie das Gerät nicht liegend
oder auf dem Kopf stehend.
Für die Geräteentwärmung muss freie Luftzirkulation möglich sein. Überhitzungsgefahr! Nach allen Seiten
mind. 5 cm Abstand!
Zulässige Umgebungstemperatur: -20 bis +55°C
Achtung:
Auf das Netzgerät dürfen keine mit Flüssigkeit gefüllten Gegenstände gestellt werden.
Das Netzgerät darf nicht Tropf- oder Spritzwasser ausgesetzt sein.
Der Netzstecker muss ohne Schwierigkeiten zugänglich und benutzbar sein.
Das Gerät kann nur durch Ziehen des Netzsteckers vom Netz getrennt werden.
Max. 2 mm Überstand
Anzugsmoment max. 3,4 Nm
(Gefahr des Überdrehens)
Durchmesser
0,6-1,2 mm gratfrei
3 / 8
Der Multischalter (mit integriertem Modem) EXI 3508 wird idealerweise in Kombination mit dem Einzelmodem EXI 01
betrieben. Das terrestrische Verteilsystem dieses Multischalters ist speziell angepasst und bietet dadurch besonders hohe
Reichweiten für die Installation (> 700 m für den Datenbereich). Ein integrierter Hochpass zum terrestrischen Eingang
verhindert eine ungewollte Verbreitung Ihrer Netzwerkdaten über eine angeschlossene Antenne.
Um eine optimale Performance zu erzielen, achten Sie bei Ihrer gesamten Verteilung (auch bei den verwendeten
Steckdosen) darauf, dass der Frequenzbereich von 5 bis 68 MHz unterstützt wird.
Info zum Koaxialverteilsystem
LED ... Status Modem
„Power“ LED Leuchtet grün Bei Betrieb
Leuchtet rot Stand-by
Ist aus Keine Spannungsversorgung
„Coax/Link“ LED Leuchtet grün Verbindung im Koaxnetz hergestellt (optimale Verbindung)
Leuchtet orange Verbindung noch gut
Leuchtet rot Schlechte Verbindung - Datendurchsatz vermindert
Ist aus Dämpfung zu hoch (> 90 dB), Unterbrechung oder kein
passender Netzwerkschlüssel
Ethernetbuchse
LED links Blinkt orange Ethernet-Aktivität
LED rechts Leuchtet grün GBit-Verbindung
Ist aus bei 100-MBit-Verbindung
Übersicht LED
Übersicht Taster
Taster wird ... Löst folgende Aktion aus ...
Pairing Kurz gedrückt (1-3 Sekunden) Weiteres Modem wird verbunden
Lang gedrückt (ca. 12 Sekunden) Modem wird zum Verbinden in ein privates Netz
vorbereitetet. Netzwerkschlüssel wird gelöscht
Reset Kurz gedrückt (1-3 Sekunden) Rücksetzen auf Werkseinstellung. Werks-Netzwerkschlüssel
wird gesetzt
2. Drücken Sie nun bei einem Ihrer Modems kurz (ca. 1 Sekunde) auf den Taster „Pairing“. Die LED „Power“ fängt an
zu blinken. Drücken Sie nun beim nächsten Modem kurz auf den Taster „Pairing“. Beide Modems handeln einen
geheimen Netzwerkschlüssel aus und verbinden sich miteinander. Sie haben für das Drücken des zweiten Tasters ca. drei
Minuten Zeit. Ist der Vorgang abgeschlossen, leuchten beide LED wieder konstant. Jedes weitere Modem kann auf die
gleiche Weise zum privaten Netzwerk hinzugefügt werden. Das Pairing kann von jedem Modem Ihres privaten Netz-
werks gestartet werden.
Zurücksetzen:
Mit dem Taster „Reset“ wird das Modem auf Werkseinstellung zurückgesetzt. Da hierbei auch der originale Werks-
Netzwerkschlüssel gesetzt wird, wird das Modem wieder allgemein sichtbar und gehört nicht mehr zum privaten Netzwerk.
Stand-by:
Das Modem schaltet nach einigen Minuten ohne Datenverkehr automatisch in den Stand-by-Modus. Die LED „Power“ blinkt
langsam (Rot - Grün).
4 / 8
Anlagenbeispiele (Symbolische Darstellung)
Netzwerk-Kabel
Sat(Koaxial)-Kabel
DVB-T(Koaxial)-Kabel
NAS
Op
pt
t
ion
al
n
n
a
al
a
a
a
l
l
al
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
n
a
a
n
n
a
a
pt
io
ion
n
n
n
n
n
DHCP-Server,
Router (z. B. Fritzbox)
Netzwerk
Twin-Receiver
Sat-Signal
Sat-Signal +
Netzwerk
Sat-Signal +
Netzwerk
2x Sat-Signal +
Netzwerk
Abschlusswider-
stand EMK 03
5 / 8
*) Trennung des IP-Frequenzbereichs von und zur terrestrischen Antenne bzw. anderen Multischaltern erfolgt durch aufgeschraubten Hochpass EXI 90
**) Trennung des IP-Frequenzbereichs von und zur terrestrischen Antenne bzw. anderen Multischaltern erfolgt hier durch integrierten Hochpass in
der EXI 3508
Problem Mögliche Ursache Fehlerbehebung
LED „Coax/Link“
leuchtet nicht
Keine Koax-Verbindung
Auf kurzschlussfreie Verbindung
der Koaxial-Kabel achten
LED „Coax/Link“
leuchtet nicht
Dämpfung zwischen den Modems
ist zu hoch
Überprüfen Sie ob der gewählte
Anschluss der HF-Steckdose den
Frequenzbereich 5-68 MHz abdeckt
LED „Coax/Link“
leuchtet nicht
Kein Pairing
Das Modem hat noch keinen gültigen
Netzwerkschlüssel. Führen Sie die
Punkte bei Inbetriebnahme durch
Mögliche Fehlerursache und deren Behebung
**)
*)*)
6 / 8
Technische Daten
Integriertes Modem
Frequenzbereich IP (IEEE 1901) MHz 2-68
5)
Bruttodatenrate Mbit 500
Stromaufnahme des Modems max. mA 200
Leistungsaufnahme bei max. Datenrate W Ca. 4,2
Leistungsaufnahme im Stand-by W Ca. 1,0
Anschlüsse RJ45
Unterstützte Standards IEEE1901
1)
Frequenzabhängige Dämpfung
2)
Nach EN 60728-3, 35-dB-IMA
3)
Modem im Standby-Modus
4)
Über Eingang horizontal low
5)
Davon aktuell genutzt: 8-68 MHz
Typ EXI 3508
Multischalter
Bestell-Nr. 20510060
Teilnehmeranschlüsse 8
Eingänge 1 x terr. 4 x Sat-ZF
Frequenzbereiche (Eingänge) MHz 87,5-862 950-2150
Frequenzbereiche (Teilnehmer) MHz 2-68/87,5-862 950-2150
Anschlussdämpfung ¹
)
dB -/15 17 5 0
Entkopplung horiz./vert. dB - 25
Entkopplung Teilnehmer dB 28/40 25
Max. Ausgangspegel ²) dBV- 110
Steuerung Eingang vert./horiz. V 12-14,5/16-19
Steuerung Low-/High-Band kHz 0/22
Stromaufnahme/Teilnehmer mA 20
Eingangsnennspannung V 230 (50-60 Hz)
Zulässiger Eingangsspannungsbereich V 207-253
Eingangsnennleistung bei 0-/150-/500-mA-Last ³
)
W 1/4/10
Spannung sekundär
4)
V18
Max. Fernspeisestrom gesamt
4)
mA 500
Max. zulässiger Fernspeisestrom pro Stamm mA -
Schutzklasse/Schutzart II (schutzisoliert)/IP 30
Zulässige Umgebungstemperatur °C -20 bis +55
Anschlüsse F-Connectoren
Abmessungen (B x H x T) mm 295 x 148 x 42,5
Verpackungs-Einheit/Gewicht St./kg 1 (10)/ca. 0,7
7 / 8
Abmessungen
Elektronische Geräte gehören nicht in den Hausmüll, sondern müssen - gemäß Richtlinie 2002/96/EG DES
EUROPÄISCHEN PARLAMENTS UND DES RATES vom 27. Januar 2003 über Elektro- und Elektronik-
Altgeräte fachgerecht entsorgt werden. Bitte geben Sie dieses Gerät am Ende seiner Verwendung zur
Entsorgung an den dafür vorgesehenen öffentlichen Sammelstellen ab.
936.4547/-/VKDT/0613/DE - Technische Änderungen vorbehalten!
Internet: www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • Postfach 10 04 44 • 83004 Rosenheim • Deutschland • Telefon 08031 184-0 • Fax 08031 184-306
1 / 8
Cascade-capable multi-switch with integral modem for
distribution of four satellite levels and terrestrial signals
to up to eight receivers
Creation of a home network using the existing
terrestrial distribution of the multi-switch.
The IP data are available at every subscriber outlet.
This reduces the cost of installation - no new network
cables need be laid
Integrated high selective diplexer for the IP data
The optimised EXI 3508 distribution system allows
distances of > 700 m to be achieved in the IP frequency
range
Integral amplifi er for low attenuation in the satellite
signal band
Integral pre-emphasis to equalise cable attenuation
Terrestrial signals are also receivable with the satellite
receiver switched off
Remote feeding over the horizontal low input. All
other inputs are voltage-free (enabling operation with
UAS 585)
For indoor installation
EXI 3508 20510060
Sat-IF distribution system (4 x Sat-IF)
Multi-switch with integral modem
Features of the multi-switch
EXI 30 (BN 21110024): Outlet remotely fed from the
SAT port, with optimum selection for data and RF
signals
EXI 01 free-standing modem (BN 20510061): For
converting back the IP data at the subscriber outlets
(for instance for connecting a satellite receiver using an
Ethernet socket).
Software EXI 700: Displays the visible modems on a
network (download from: www.kathrein.de)
EXI 90 high-pass fi lter (BN 20510062): If other multi-
switches (not from the EXI range) are cascaded and if
the EXI 01 is driven from ones of these multi-switches,
the high-pass fi lter must be screwed to the terrestrial
input of the multi-switch. This isolates the downstream
multi-switch in the cascade and prevents reception
and emission in the IP frequency range by and from
the terrestrial antenna The high-pass fi lter is already
incorporated in the EXI 3508.
Accessories
*
)
Quality of Service
**
)
Alternatively the ESD 84 and ESD 32 outlets can also be used
Features of the integral modem
Modem for the Kathrein IP over coax system “K-LAN”
(based on the IEEE 1901 standard)
Ideal for the network connection of receivers, TV sets
and Blu-ray players. In addition, a PC and other
network-capable devices can easily be connected
via a router (such as Fritzbox)
> 500-Mbit data throughput (gross) is suffi cient for
several HD streams plus data transmission between
PCs. QoS *
)
allows prioritisation of the respective
services.
High screening factor prevents interference
128-bit AES encryption. Secure private network
connection at the push or a button - no software
required
Existing outlets can continue to be used, providing they
support the frequency range 5-68 MHz. Otherwise the
use of the EXI 30 socket specially developed for K-LAN
is recommended. **
)
Eco Power Mode: The modem automatically switches
to stand-by until it is “woken up” again by the network.
Consumption: 1.0 Watt in stand-by/4.2 Watt in
operation
2 / 8
An inner cable conductor
diameter greater than 1.2 mm,
or the presence of burrs may
damage the sockets on the unit
beyond repair.
The integral modem within the EXI 3508 multi-switch and the Kathrein EXI 01 modem are protected with a factory-
set network security key. For simple commissioning of the two modems, connect a coaxial cable to the socket
.
The network devices to be connected, such as the router and receiver, are connected using the Ethernet cable included.
This is plugged in to the RJ 45 socket provided. The “Power” and “Coax/Link” LEDs light up. The data connection is
established. Up to 64 modems can be linked together in this way.
Additional security:
In a coaxial distribution system, all the connected Kathrein modems can “see” each other. If you wish to build a private
network with the modems that belong to you, proceed as follows:
1. Press the “Pairing” button and keep it depressed for approx. 12 seconds. Both LEDs go out brie y. The network key
is deleted. The “Power” LED lights up, but the “Coax/Link” LED remains off. Perform this step for all the devices that
you wish to add to your private network!
Commissioning the modem
Installation and safety instructions
The equipment described is designed solely for the installation of satellite receiver systems.
Any other use, or failure to comply with these instructions, will result in voiding of warranty cover.
The equipment may only be installed in dry areas indoors. Do not install on or against highly combustible
materials.
The equipment must be provided with an earthing wire (Cu, at least 4 mm
2
).
The safety regulations set out in the current EN 60728-11 and EN 60065 standards must be complied with.
Fixings: Wood screws, max Ø: 4 mm
(not included)
Connectors: RF plugs 75 (series F) to EN 61169-24.
Unused RF ports must be terminated with 75 resistors (e.g. EMK 03).
Electrically live unit
Do not open the unit or tamper with it!
When working on the system always unplug the mains plug from the wall socket!
The device is intended only for wall mounting! Do not install the device lying at or on its top, or operate it
in this position.
There must be free circulation of air to dissipate the heat from the unit. Risk of overheating! Clearance all
round must be at least 5 cm!
Ambient temperature range: -20 to +55°C
Important:
Do not place liquid- lled items on top of the power supply unit.
The power supply unit must not be exposed to dripping or splashing water.
The mains plug must be easily accessible and operable.
The only reliable method of disconnecting the unit from the mains is to unplug it.
Max. 2 mm protrusion
Tightening torque max. 3.4 Nm
(risk of overtightening)
Diameter
0.6-1.2 mm with no burr
3 / 8
The EXI 3508 multi-switch (with integral modem) should ideally be operated in combination with the EXI 01 free-
standing modem. The terrestrial distribution system of this multi-switch is specially matched to this application and
thus offers especially long range capabilities for the installation (> 700 m for the data range). An integral high-pass fi lter
for the terrestrial input prevents undesirable propagation of your network data from a connected antenna.
To achieve optimum performance, make sure that all components of the overall distribution system (including the outlets
used) support the frequency range of 5 to 68 MHz.
Info on the coaxial distribution system
LED ... Modem status
“Power” LED Lights up green In operation
Lights up red Stand-by
Is off No power supply
“Coax/Link” LED Lights up green Connection established in the coax network (optimum
connection)
Lights up orange Connection still OK
Lights up red Bad connection - data throughput restricted
Is off Damping too high (> 90 dB), cable breakage or no matching
network key
Ethernet socket
Left hand LED Flashes orange Ethernet activity
Right hand LED Lights up green GBit connection
Is off at 100 MBit connection
Overview of the LEDs
Overview of buttons
Button is ... Triggers the following action ...
Pairing Pressed brie y (1-3 seconds) A further modem is connected
Pressed longer (approx. 12 seconds) Modem is prepared for connection into a private network.
Network key is deleted
Reset Pressed brie y (1-3 seconds) Reset to factory setting. The factory setting for the network
key is restored
2. Now brie y press the “Pairing” button on one of your modems (for approx. 1 second). The “Power” LED starts to
ash. Now at the next modem brie y press the “Pairing” button. The two modems exchange a secret network key
and connect to each other. You must press the second button within approx. three minutes after the rst. Once
the procedure is complete, both LEDs light up continuously again. Each further modem can be added to the
private network in the same way. The pairing can be started at any modem on your private network.
Resetting:
Pressing the “Reset” button resets the modem to its factory settings. Since this also restores the original factory setting
for the network key, the modem is now once again generally visible and no longer belongs to your private network.
Stand-by:
After a few minutes with no data traf c, the modem switches itself automatically into stand-by mode. The “Power” LED
ashes slowly (red - green).
4 / 8
System examples (symbolic representation)
Netzwerk-Kabel
Sat(Koaxial)-Kabel
DVB-T(Koaxial)-Kabel
NAS
Op
pt
t
ion
al
n
n
a
al
a
a
a
l
l
al
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
n
a
a
n
n
a
a
pt
io
ion
n
n
n
n
n
n
DHCP-Server,
Router (z. B. Fritzbox)
Netzwerk
Twin-Receiver
Sat-Signal
Sat-Signal +
Netzwerk
Sat-Signal +
Netzwerk
2x Sat-Signal +
Netzwerk
Terminating
resistor EMK 03
Network cable
Sat (coaxial) cable
DVB-T (coaxial) cable
Network
Sat signal
DHCP server,
router (e.g. Fritzbox)
2x sat signal +
network
Sat signal +
network
Sat signal +
network
Twin receiver
Optional
5 / 8
*) Separation of the IP frequency range by and from the terrestrial antenna and other downstream multi-switches is performed by the screwed-on
EXI 90 high-pass fi lter
**) Separation of the IP frequency range by and from the terrestrial antenna and other downstream multi-switches is performed here by the integral
high-pass fi lter within the EXI 3508
Problem Possible cause Solution
“Coax/Link” LED
does not light up
No coax connection
Ensure the coaxial cables are
connected without any short circuits
“Coax/Link” LED
does not light up
Damping between the modems
is too high
Check whether the selected port on
the RF outlet/multi-switch supports
the frequency range 5-68 MHz
“Coax/Link” LED
does not light up
No pairing
The modem has not yet been assigned
a valid network key. Perform the
relevant points during commissioning
Possible causes of faults, and their remedies
**)
*)*)
6 / 8
Technical Specifi cations
Integral modem
Frequency range IP (IEEE 1901) MHz 2-68
5)
Gross data rate Mbit 500
Current consumption of the modem, max. mA 200
Power consumption at max. data rate W Approx. 4.2
Power consumption in stand-by W Approx. 1.0
Connections RJ45
Standards supported IEEE1901
1)
Frequency-dependent attenuation
2)
To EN 60728-3, 35-dB-IMA
3)
Modem in standby
4)
Via horizontal low input
5)
Of which actually used: 8-68 MHz
Type EXI 3508
Multi-switch
Part no. 20510060
Subscriber connections 8
Inputs 1 x terr. 4 x sat-IF
Frequency range (inputs) MHz 87.5-862 950-2150
Frequency range (subscribers) MHz 2-68/87.5-862 950-2150
Attenuation ¹
)
dB -/15 17 5 0
Horizontal/vertical isolation dB - 25
Subscriber decoupling dB 28/40 25
Max. output level ²) dBV- 110
Vertical/horizontal input control V 12-14.5/16-19
Low/High band control kHz 0/22
Current consumption per subscriber mA 20
Nominal input voltage V 230 (50-60 Hz)
Rated input voltage range V 207-253
Nominal input power at 0/150/500 mA load ³
)
W 1/4/10
Secondary voltage
4)
V18
Max. total remote feed current
4)
mA 500
Max. permissible remote feed current per trunk mA -
Protection class/protection type II (double insulated)/IP 30
Permissible ambient temperature °C -20 to +55
Connections F connectors
Dimensions (W x H x D) mm 295 x 148 x 42.5
Packing unit/weight Units/kg 1 (10)/approx. 0.7
7 / 8
Dimensions
Electronic equipment is not domestic waste; it must be disposed of properly in accordance with directive
2002/96/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 27 January 2003 on waste
electrical and electronic equipment. At the end of its service life, please take this device to a designated
public collection point for disposal.
42.5
936.4547/-/VKDT/0613/GB - Technical data subject to change.
Internet: www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • P.O. Box 100 444 • 83004 Rosenheim • GERMANY • phone +49 8031 184-0 • Fax +49 8031 184-306
1 / 8
Commutateur multiple avec modem intégré, possibilité
de mise en cascade, pour la distribution de quatre
niveaux Sat et signaux terrestres sur huit récepteurs
au plus
Création d'un réseau local via l'installation de
distribution terrestre existante du commutateur multiple.
Les données IP sont disponibles à chaque sortie des
abonnés. Cela réduit les frais d'installation : aucun
nouveau câblage n'est requis
Répartiteur intégré à sélection stricte pour les
données IP
Grâce au système de distribution optimisé du EXI 3508,
des distances de plus de 700 m pour la plage de
fréquence IP sont possibles
Amplifi cateur intégré pour des atténuations de
raccordement réduites dans la plage satellite
Préaccentuation intégrée pour compensation de
l’atténuation de câble
Possibilité de réception de signaux terrestres même
lorsque le récepteur satellite est désactivé
Possibilité de téléalimentation via l’entrée horizontal
low. Toutes les autres entrées sont sans tension
(donc compatibilité avec UAS 585)
Pour montage en intérieur
EXI 3508 20510060
Système de distribution FI Sat (4 x FI Sat)
Commutateur multiple avec modem intégré
Caractéristiques du commutateur multiple
EXI 30 (BN 21110024) : prise téléalimentable via le
raccordement Sat avec sélection optimale pour les
données et les signaux HF
Modem simple EXI 01 (BN 20510061) : Pour la
reconversion des données IP sur les prises des
abonnées (p.ex. pour raccorder un récepteur Sat sur
une prise Ethernet).
Logiciel EXI 700 : Affi che les modem visibles d'un
réseau (téléchargement via : www.kathrein.de)
Passe-haut EXI 90 (BN 20510062) : Si d'autres com-
mutateurs multiples (qui ne sont pas de la gamme
EXI) sont cascadés et si le EXI 01 est exécuté sur ce
commutateur multiple, le passe-haut doit être vissé sur
l'entrée terrestre du commutateur multiple. De cette
manière, les commutateurs multiples suivants sont
isolés dans la cascade, et les insolations et rayonne-
ments de la plage de fréquence IP de et vers l'antenne
terrestre sont bloqués. Dans le EXI 3508, le passe-haut
est déjà intégré.
Accessoires
*
)
Quality of Service
**
)
Il est également possible d'utiliser les prises ESD 84 et ESD 32
Caractéristiques du modem intégré
Modem pour IP Kathrein via système Coax « K-LAN »
(sur la base de la norme IEEE 1901)
Idéal pour la connexion réseau des récepteurs, télé-
viseurs et lecteurs blue-ray. Il est également possible
de raccorder facilement d'autre appareils compatibles
réseau à l'aide d'un routeur (p. ex. Fritzbox)
Débit brut > 500-Mbits, autorise la présence de
plusieurs ux HD en cas de transmission simultanée
entre ordinateurs. QoS *
)
permet de prioriser les
services concernés.
Insensibilité aux brouillages grâce à un fort facteur de
blindage
Encryptage 128 bits. Connexion réseau privé sécurisé
par touche, pas de logiciel requis
Les prises déjà existantes qui prennent en charge
la plage de fréquence 5-68 MHz peuvent encore
être utilisées. Sinon, il est recommandé d'utiliser
la une prise spécialement conçue pour le réseau
K-LAN EXI 30. **
)
Mode Eco Power : Le modem passe automatiquement
en veille et est réactivé par le réseau. Consommation :
1,0 Watt en veille/4,2 Watt en service
2 / 8
Si le diamètre du conducteur
interne est supérieur 1,2 mm
ou en présence d’ébarbures,
les connecteurs femelles de
l’appareil sont susceptibles
d’être endommagés.
Le modem intégré dans le commutateur multiple EXI 3508 et le modem EXI 01 Karthrein sont protégés départ usine
par une clé réseau. Pour une mise en service simple d'un deuxième modem, celui-ci doit être raccordé à la prise par un
câble coaxial
. Les appareils réseaux à raccorder, p.ex. le routeur et le récepteur sont branchés sur la prise RJ 45
prévue à l'aide du câble Ethernet fourni. Les LEDs « Power » et « Coax/Link » sont allumées. La connexion données
est établie. Il est possible de raccorder jusqu'à 64 modem.
Protection supplémentaire :
Dans un système de distribution coaxial tous les modem Kathrein raccordés sont visibles. Pour construire un réseau
privé avec vos modem, procédez comme suit :
1. Appuyez environ 12 secondes sur le bouton « Pairing » (pairage). Les deux LED s'éteignent brièvement. La clé
réseau est supprimée. La LED « Power » s’allume, « Coax/Link » reste éteinte. Exécutez cette étape sur tous les
appareils que vous voulez intégrer à un réseau privé!
Mise en service du modem
Consignes de montage et de sécurité
Les appareils décrits sont exclusivement destinés à l'installation de systèmes de réception satellite.
Tout autre usage, de même que le non respect des présentes consignes, entraînera l’annulation de la
garantie.
Les appareils ne doivent être montés que dans des environnements intérieurs secs. Ne pas l’installer sur
ou à proximité de matériaux facilement in ammables.
Les appareils doivent être munis d'une ligne équipotentielle (Cu, au moins 4 mm
2
).
Observer les consignes de sécurité des normes EN 60728-11 et EN 60065.
• Dispositifs de xation : vis à bois, max. Ø : 4 mm
(non fournie)
Connecteurs : connecteurs HF 75 (série F) selon EN 61169-24.
Les connexions HF inutilisées doivent être chargées par des résistances de 75 (par ex. EMK 03).
Appareil sous tension
Ne pas ouvrir ou manipuler l’appareil !
Systématiquement débrancher la che d’alimentation de la prise avant d’intervenir sur l’installation !
L'appareil est prévu uniquement pour le montage mural ! Ne pas monter ni utiliser l'appareil en position
couchée ou posée à l'envers.
L’évacuation de la chaleur de l’appareil suppose une circulation suf sante de l’air. Risque de surchauffe !
Écart d'au moins 5 cm de tous côtés !
Température ambiante admissible : -20 à +55°C
Attention :
Ne poser aucun objet contenant du liquide sur le bloc d'alimentation.
Préserver l'appareil électrique des gouttes ou des projections d'eau.
• La che d'alimentation doit rester facilement accessible.
Ne débrancher l’appareil du secteur qu’en tirant sur la che secteur.
Dépassement max. 2 mm
Couple de serrage
max. 3,4 Nm (risque
de serrage excessif)
Diamètre
0,6-1,2 mm sans bavures
3 / 8
Le commutateurs multiples (avec modem intégré) EXI 3508 est utilisé de préférence en combinaison avec le modem
simple EXI 01. Le système de distribution terrestre de ce commutateur multiple est spécialement adapté et offre ainsi à
l'installation une grande portée (> 700 m pour la plage de données). Un passe-haut intégré vers l'entrée terrestre bloque
toute émission involontaire des données réseau via une antenne raccordée.
Pour obtenir une performance optimale, l'ensemble de la distribution (également pour les prises utilisées) doit prendre
en charge la plage de fréquence comprise entre 5 et 68 MHz.
Informations sur le système de distribution coaxial
LED ... Etat modem
LED « Power » Lumière verte continue en marche
Lumière rouge continue Veille
Arrêt Pas d'alimentation
LED « Coax/
Link »
Lumière verte continue Connexion établie dans le réseau coaxial (connexion
optimale)
Lumière orange continue Connexion encore bonne
Lumière rouge continue Connexion mauvaise - Débit de données réduit
Arrêt Atténuations trop haute (> 90 dB), interruption ou pas de clé
réseau adaptée
Prise Ethernet
LED gauche Lumière orange clignotante Activité Ethernet
LED de droite Lumière verte continue Connexion Gbit
Arrêt pour une connexion 100 Mbits
Vue d'ensemble des LED
Vue d'ensemble des boutons
Le bouton ... Déclenche la fonction suivante ...
Pairing (pairage) Pression brève (1-3 secondes) Un autre modem est connecté
Pression longue (env. 12 secondes) Le modem est préparé pour être raccordé à un réseau privé.
La clé réseau est supprimée
Reset
(rénitialisation)
Pression brève (1-3 secondes) Restauration des réglage usine. La clé réseau d'origine est
créée
2. Appuyez brièvement (environ 1 seconde) sur le bouton « Pairing » (pairage) d'un des modem. La LED « Power »
clignote. Appuyez ensuite brièvement sur le bouton « Pairing » (pairage) du modem suivant. Les deux modem
échangent une clé réseau secrète et se connectent entre eux. Vous avez environ trois minutes pour appuyer sur
le deuxième bouton. Une fois la procédure terminée, les deux LED restent allumées en continu. Procédez de
la même manière pour tous les autres modem à raccorder au réseau privé. Le pairage peut être lancé à partir de
chaque modem du réseau privé.
Réinitialiser :
Le bouton « Reset » permet de réinitialiser le modem sur ses paramètres d'usine. Sachant que que la clé réseau
d'origine est également restaurée, le modem redevient visible et ne fait plus partie du réseau privé.
Veille :
Le modem passe automatiquement en mode veille après quelques minutes sans transfert de données. La LED
« Power » clignote lentement (rouge - vert).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41

Kathrein 20510060 Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per