Fujitsu ASHA12KLWA Istruzioni per l'uso

Tipo
Istruzioni per l'uso

Questo manuale è adatto anche per

SPLIT-TYPE ROOM AIR CONDITIONER
CS78421-548-754
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Owner’s Manual
ON/ OFF
TEM P
TIM ER
ON
TIM ER
OFF
MOD E
FAN
SLE EP
SWI NG
DIR ECT
TUR BO
CLE AN
LED
FOL LOW
SIL ENCE
FP
Safety Precautions.......................................................04
Unit Specifications and Features
..............................0
Table of Contents
Owner’s Manual
0
1
SAFETY
FIRST
Manual Operation
(Without Remote)
................
2
ON/OFF
TEMP
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
SWING
DIRECT
TURBO
CLEAN
LED
FOLLOW
SILENCE
FP
6
11
Care and Maintenance
.....................................................
Troubleshooting...................................................................
3
4
European Disposal Guidelines....................................
5
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants. For more details ,please refer to the Information on
servicing on INSTALLATION MANUAL .(This is only required for the unit adopts R32/R290 Refrigerant)
Caution: Risk of fire/
flammable materials
,, ,,
,,
,,
(For R32/R290 units only)
1
12
4
1
9
Page 4
Safety Precautions
Read Safety Precautions Before Installation
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
WARNING
This symbol indicates that ignoring instructions may cause death or serious
Incorrect installation due to ignoring instructions can cause serious damage or injury.
injury.
This symbol indicates that ignoring instructions may cause moderate injury
to your person, or damage to your appliance or other property.
CAUTION
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
INSTALLATION WARNINGS
Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water
leakage, electric shock, or fire.
All repairs, maintenance and relocation of this unit must be performed by an authorized service
technician. Inappropriate repairs can lead to serious injury or product failure.
WARNINGS FOR PRODUCT USE
If an abnormal situation arises (like a burning smell), immediately turn off the unit and pull the
power plug. Call your dealer for instructions to avoid electric shock, fire or injury.
Do not
insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since
the fan may be rotating at high speeds.
Do not
use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause
fire or combustion.
Do not
operate the air conditioner in places near or around combustible gases. Emitted gas may
collect around the unit and cause explosion.
Do not
operate the air conditioner in a wet room (e.g., bathroom or laundry room). This can
cause electrical shock and cause the product to deteriorate.
Do not
expose your body directly to cool air for a prolonged period of time.
Safety
Precautions
Safety
Precautions
Page 5
ELECTRICAL WARNINGS
Only use the specified power cord. If the power cord is damaged, it must be replaced by the
manufacturer or certified service agent.
Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty
plugs can cause fire or electric shock.
Do not
pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling
directly on the cord can damage it, which can lead to fire or electric shock.
Do not
use an extension cord, manually extend the power cord, or connect other appliances to
the same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient
voltage can cause fire.
CLEANING AND MAINTENANCE WARNINGS
Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.
Do not
clean the air conditioner with excessive amounts of water.
Do not
clean the air conditioner with combustible cleaning agents. Combustible cleaning agents
can cause fire or deformation.
CAUTION
If the air conditioner is used together with burners or other heating devices, thoroughly ventilate
the room to avoid oxygen deficiency.
Turn off the air conditioner and unplug the unit if you are not going to use it for a long time.
Turn off and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not
operate the air conditioner with wet hands. This may cause electric shock.
Do not
use device for any other purpose than its intended use.
Do not
climb onto or place objects on top of the outdoor unit.
Do not
allow the air conditioner to operate for long periods of time with doors or windows open,
or if the humidity is very high.
CAUTION
CAUTION
CAUTION
CAUTION
WARNING
This symbol shows that this appliance used a flammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is
a risk of fire.
This symbol shows that the operation manual should be read carefully.
This symbol shows that information is available such as the operating
manual or installation manual.
This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
Explanation of symbols displayed on the indoor unit or outdoor unit
(For the unit adopts R32/R290 Refrigerant only):
Unit Specifications and Features
1
Unit
Specifications
and Features
NOTE:
A guide on using the infrared remote is not included
in this literature package.
Unit Parts
Power Cable (Some Units)
Remote Control
Remote Control
Holder(Some Units)
Louver
Front Panel
Display window
“ ” when defrost feature is activated.
“ ” when the unit is on.
“ ” when TIMER is set.
Display Code
Meanings
ON/OF F
TEMP
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
SWING
DIREC T
TURBO
CLEAN
LED
FOLLO W
SILEN CE
FP
Page 6
Unit
Specifications
and Features
For a detailed explanation of each function,
refer to the Remote Control Manual.
Other Features
Auto-Restart
If the unit loses power, it will automatically
restart with the prior settings once power has
been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up
condensed water and prevent mildew growth.
Wireless Control (some units)
Wireless control allows you to control
your air conditioner using your mobile
phone and a Wireless connection.
Louver Angle Memory(some units)
When turning on your unit, the louver
will automatically resume its former
angle.
Refrigerant Leakage Detection
(some units)
The indoor unit will automatically
display “EC” when the unit detects
refrigerant leakage.
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor
unit may be slightly different. The actual shape shall prevail.
For a detailed explanation of your unit’s
advanced functionality (such as TURBO
mode and its self-cleaning functions),
refer to the Remote Control Manual.
For the USB device access, replacement,
maintenance operations must be carried
out by professional staff.
Page
8
Setting vertical angle of air flow
While the unit is on, use the
SWING/DIRECT
button to set the dir
ection (vertical angle) of
airflow
.
1.
Pr
ess the
SWING/DIRECT
button once to
activate the louver
. Each time you pr
ess
the button, it will adjust the louver by 6°.
Pr
ess the button until the dir
ection you
pr
efer is reached.
2.
T
o make the louver swing up and down
continuously
, pr
ess and hold the
SWING/
DIRECT
button for 3 seconds. Press it
again to stop the automatic function.
The horizontal angle of the airflow must be set
manually
. Grip the deflector r
od (See
Fig.B
)
and manually adjust it to your pr
eferred direction.
For some units,
the horizontal angle of the airflow
can be set by remote control. please refer to the
Remote Control Manual.
NOTE ON LOUVER ANGLES
When using COOL or DR
Y mode, do not set
louver at too vertical an angle for long periods
of time. This can cause water to condense on
the louver blade, which will dr
op on your floor
or fur
nishings. (See
Fig.A
)
When using COOL or HEAT mode, setting the
louver at too vertical an angle can r
educe the
performance of the unit due to r
estricted air
flow
.
Do not move louver by hand. This will cause the
louver to become out of sync. If this occurs, tur
n
of
f the unit and unplug it for a few seconds,
then restart the unit. This will reset the louver
.
Fig. A
CAUTION
Do not put your fingers in or near the blower
and suction side of the unit. The high-speed
fan inside the unit may cause injury
Fig. B
Setting Angle of Air Flow
Setting horizontal angle of air flow
Unit
Specifications
and Features
Caution: Do not keep louver at too
vertical an angle for long periods of
time. This can cause water condensation
to drip on your furnishings.
Page
9
Range
Deflector rod
Set
temperatur
e
Saving energy during sleep
1hr
1hr
7 hours
timer o
+/- 1 C/2 F
SLEEP Operation
+/- 1 C/2 F
Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same
temperature settings to stay comfortable). This function can only be activated via remote
control. Press the
SLEEP
button when you are ready to go to sleep.
When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will
increase an additional 1°C (2°F) after another hour.
When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour, and will
decrease an additional 1°C (2°F) after another hour. It will hold the new temperature for 5
hours, then the unit will turn off automatically.
Note: The SLEEP function is not available in FAN or DRY mode.
Unit
Specifications
and Features
Page
10
How to operate your unit without
the remote control
In the event that your remote control fails to
work, your unit can be operated manually with
the MANUAL CONTROL button located on
the indoor unit. Note that manual operation is
not a long-term solution, and that operating
the unit with your remote control is strongly
recommended.
BEFORE MANUAL OPERATION
Unit must be turned off before manual
operation.
To operate your unit manually:
1. Open the front panel of the indoor unit.
2. Locate the
MANUAL CONTROL button on
the right-hand side of the unit.
3. Press the MANUAL CONTROL button one
time to activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again
to activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third
time to turn the unit off.
6. Close the front panel.
Manual Operation (Without Remote)
2
CAUTION
Manual Operation
(Without Remote)
Manual control button
The manual button is intended for testing
purposes and emergency operation only. Please
do not use this function unless the remote control
is lost and it is absolutely necessary. To restore
regular operation, use the remote control to
activate the unit.
Page
11
Care and Maintenance
3
Care and
Maintenance
Cleaning Your Indoor Unit
BEFORE CLEANING OR
MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER
SYSTEM AND DISCONNECT ITS POWER SUPPLY
BEFORE CLEANING OR MAINTENANCE.
CAUTION
Only use a soft, dry cloth to wipe the unit clean.
If the unit is especially dirty, you can use a cloth
soaked in warm water to wipe it clean.
Do not
use chemicals or chemically treated
cloths to clean the unit
Do not use benzene, paint thinner,
polishing powder or other solvents to clean
the unit. They can cause the plastic surface
to crack or deform.
Do not use water hotter than 40°C (104°F)
to clean the front panel. This can cause the
panel to deform or become discolored.
Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling
efficiency of your unit, and can also be bad for
your health. Make sure to clean the filter once
every two weeks.
6.
Rinse the filter with fresh water, then shake
off excess water.
7.
Dry it in a cool, dry place, and refrain from
exposing it to direct sunlight.
8.
When dry, re-clip the air freshening filter to
the larger filter, then slide it back into the
indoor unit.
9.
Close the front panel of the indoor unit.
CAUTION
Do not touch air freshening (Plasma) filter for
at least 10 minutes after turning off the unit.
1. Lift the front panel of the indoor unit.
2. First press the tab on the end of filter to
loosen the buckle, lift it up, then pull it
towards yourself.
3.
Now pull the filter out.
4. If your filter has a small air freshening filter,
unclip it from the larger filter. Clean this air
freshening filter with a hand-held vacuum.
5. Clean the large air filter with warm, soapy
water. Be sure to use a mild detergent.
Remove air freshening ilter from back of
larger filter (some units)
Filter Tab
Page
12
3
CAUTION
Before changing the filter or cleaning,
turn off the unit and disconnect its power
supply.
When removing filter, do not touch metal
parts in the unit. The sharp metal edges can
cut you.
Do not use water to clean the inside of the
indoor unit. This can destroy insulation and
cause electrical shock.
Do not expose filter to direct sunlight when
drying. This can shrink the filter.
Maintenance –
Long Periods of Non-Use
If you plan not to use your air conditioner for an
extended period of time, do the following:
Clean all filters
Turn on FAN function until
unit dries out completely
Turn off the unit and
disconnect the power
Remove batteries
from remote control
Maintenance –
Pre-Season Inspection
After long periods of non-use, or before periods
of frequent use, do the following:
Check for damaged wires Clean all filters
Check for leaks Replace batteries
Make sure nothing is blocking all air inlets and outlets
Care and
Maintenance
CAUTION
Any maintenance and cleaning of outdoor
unit should be performed by an authorized
dealer or a licensed service provider.
Any unit repairs should be performed
by an authorized dealer or a licensed
service provider.
Page
13
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
The power cord is damaged or abnormally warm
You smell a burning odor
The unit emits loud or abnormal sounds
A power fuse blows or the circuit breaker frequently trips
Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER
IMMEDIATELY!
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn
on when pressing
ON/OFF button
The Unit has a 3-minute protection feature that prevents the
unit from overloading. The unit cannot be restarted within
three minutes of being turned off.
The unit may change its setting to prevent frost from forming
on the unit. Once the temperature increases, the unit will start
operating in the previously selected mode again.
The set temperature has been reached, at which point the
unit turns off the compressor. The unit will continue operating
when the temperature fluctuates again.
The indoor unit
emits white mist
In humid regions, a large temperature difference between the
room’s air and the conditioned air can cause white mist.
Both the indoor
and outdoor units
emit white mist
When the unit restarts in HEAT mode after defrosting, white
mist may be emitted due to moisture generated from the
defrosting process.
Troubleshooting
4
Troubleshooting
The unit changes
from COOL/HEAT
mode to FAN
mode
Page
14
4
Issue Possible Causes
The indoor unit
makes noises
A rushing air sound may occur when the louver resets its
position.
A squeaking sound may occur after running the unit in HEAT
mode due to expansion and contraction of the unit’s plastic
parts.
Both the indoor
unit and outdoor
unit make noises
Low hissing sound during operation: This is normal and is
caused by refrigerant gas flowing through both indoor and
outdoor units.
Low hissing sound when the system starts, has just stopped
running, or is defrosting: This noise is normal and is caused by
the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of
plastic and metal parts caused by temperature changes during
operation can cause squeaking noises.
The outdoor unit
makes noises
The unit will make different sounds based on its current
operating mode.
Dust is emitted
from either the
indoor or outdoor
unit
The unit may accumulate dust during extended periods of
non-use, which will be emitted when the unit is turned on.
This can be mitigated by covering the unit during long periods
of inactivity.
The unit emits a
bad odor
The unit may absorb odors from the environment (such as
furniture, cooking, cigarettes, etc.) which will be emitted
during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the
outdoor unit does
not operate
During operation, the fan speed is controlled to optimize
product operation.
Operation
is erratic,
unpredictable,
or unit is
unresponsive
Interference from cell phone towers and remote boosters may
cause the unit to malfunction.
In this case, try the following:
Disconnect the power, then reconnect.
Press ON/OFF button on remote control to restart operation.
NOTE: If problem persists, contact a local dealer or your nearest customer service
center. Provide them with a detailed description of the unit malfunction as
well as your model number.
Troubleshooting
Page
15
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem Possible Causes Solution
Poor Cooling
Performance
Temperature setting may
be higher than ambient
room temperature
Lower the temperature setting
The heat exchanger on the
indoor or outdoor unit is
dirty
Clean the affected heat exchanger
The air filter is dirty
Remove the filter and clean it
according to instructions
The air inlet or outlet of
either unit is blocked
Turn the unit off, remove the
obstruction and turn it back on
Doors and windows are
open
Make sure that all doors and
windows are closed while
operating the unit
Excessive heat is generated
by sunlight
Close windows and curtains
during periods of high heat or
bright sunshine
Too many sources of heat
in the room (people,
computers, electronics,
etc.)
Reduce amount of heat sources
Low refrigerant due to leak
or long-term use
Check for leaks, re-seal if
necessary and top off refrigerant
SILENCE function is
activated(optional function)
SILENCE function can lower
product performance by reducing
operating frequency. Turn off
SILENCE function.
Troubleshooting
Page
16
Page
Problem Possible Causes Solution
The unit is not
working
Power failure
Wait for the power to be
restored
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are
dead
Replace batteries
The Unit’s 3-minute protection
has been activated
Wait three minutes after
restarting the unit
Timer is activated Turn timer off
The unit starts and
stops frequently
There’s too much or too little
refrigerant in the system
Check for leaks and
recharge the system with
refrigerant.
Incompressible gas or
moisture has entered the
system.
Evacuate and recharge the
system with refrigerant
The compressor is broken Replace the compressor
The voltage is too high or
too low
Install a manostat to
regulate the voltage
Poor heating
performance
The outdoor temperature is
extremely low
Use auxiliary heating
device
Cold air is entering through
doors and windows
Make sure that all doors
and windows are closed
during use
Low refrigerant due to leak or
long-term use
Check for leaks, re-seal
if necessary and top off
refrigerant
Indicator lamps
continue flashing
The unit may stop operation or continue to run safely. If
the indicator lamps continue to flash
,
minutes. The problem may resolve itself.
the power, then connect it again. Turn
the unit on.
If the problem persists, disconnect the power and contact
your nearest customer service center.
NOTE:
If your problem persists after performing the checks and diagnostics above, turn
off your unit immediately and contact an authorized service center.
Troubleshooting
17
wait for about 10
If not, disconnect
IPM malfunction or IGBT over-strong current protection
High temperature protection of IPM module
Inverter compressor drive error
Page
European Disposal Guidelines
This appliance contains refrigerant and other potentially hazardous materials. When disposing of
this appliance, the law requires special collection and treatment. Do not dispose of this product as
household waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
Dispose of the appliance at designated municipal electronic waste collection facility.
When buying a new appliance, the retailer will take back the old appliance free of charge.
The manufacturer will take back the old appliance free of charge.
Sell the appliance to certified scrap metal dealers.
Special notice
Disposing of this appliance in the forest or other natural surroundings endangers your health and is
bad for the environment. Hazardous substances may leak into the ground water and enter the food
chain.
Disposal
Information
5
1
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Fujitsu ASHA12KLWA Istruzioni per l'uso

Tipo
Istruzioni per l'uso
Questo manuale è adatto anche per