3 Secure PIN Entry
If your application supports it, the PIN entry is not
transmitted to the system, but instead transferred
directly from the keypad (alphanumeric and
numeric) of the keyboard to the chip card.
Confirm the PIN by using one of the two "Enter"
keys.
Abort the process by using the "Esc" key or the "+"
key on the number block.
Correct your entry with the "Backspace" key or the
"–" key on the number block.
4Tips
4.1 Cleaning the keyboard
1 Switch off the PC.
2 Clean the keyboard with a slightly damp cloth
and some mild cleaning agent (e.g. dish washing
liquid).
3 Dry off the keyboard with a soft, lint-free cloth.
4.2 RSI syndrome
4.3 Troubleshooting
• Use another USB port on the PC/laptop.
• To make sure that the keyboard is not defective,
test it if possible with another PC/laptop.
• Set the option "USB Keyboard Support" or "USB
Legacy Mode" to enabled in the BIOS of the PC.
5Disposal
Dispose of the used device at an official
collection point for electronic waste or at
your local dealer.
6 Technical data
LED Status
LED DATA lights up blue Voltage to the card
LED DATA flashes blue Data transmission
LED PIN lights up red Keyboard is in the
Secure PIN Entry mode
CAUTION: Damage may be caused by
harsh cleaning agents or liquids in the
keyboard
• Do not use solvents such as gasoline or
alcohol and scouring agents or scouring
sponges for cleaning.
• Prevent liquids from entering the keyboard.
• Do not remove the keycaps of the keyboard.
RSI stands for "Repetitive Strain
Injury". RSI arises due to small
movements continuously repeated
over a long period of time.
Typical symptoms are discomfort in the fingers or
neck.
• Set up your workspace ergonomically.
• Position the keyboard and mouse in such a
manner that your upper arms and wrists are
outstretched and to the sides of your body.
• Take several short breaks, with stretching
exercises if necessary.
• Change your posture often.
Designation Value
Card reading unit 100,000 insertions
Protocols T=0, T=1, (S=8, S=9, S=10
with SyncAPI)
7Contact
Please provide the following information about the
device when you make an enquiry:
• Item and serial no. of the product
• Name and manufacturer of your system
• Operating system and, if applicable, installed
service pack version
For Europe
Cherry Europe GmbH
Cherrystraße 2
91275 Auerbach/OPf.
Germany
Internet: www.cherry.de
For USA
Cherry Americas, LLC
5732 95th Avenue
Suite 850
Kenosha, WI 53144
USA
Tel.: +1 262 942 6508
Email: sales@cherryamericas.com
Internet: www.cherryamericas.com
8 General advice
We reserve the right to make technical
modifications which serve the development of our
products. Improper use and storage can lead to
faults and damage to the product.
These instructions are only valid for the supplied
product.
9Warranty
The statutory warranty applies. Please contact your
specialist dealer or contractual partner.
The warranty expires completely once unauthorized
modifications to the product have been carried out.
Do not carry out any unauthorized repairs and do
not open up the product.
10 Certifications
10.1 Federal Communications
Commission (FCC) Radio
Frequency Interference
Statement
Information to the user: This equipment has been
tested and found to comply with the limits for
Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide
reasonable protection against harmful interference
in a residential installation. This equipment
generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:
• Reorientate or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
Supply voltage 5.0 V/DC ±5% SELV
Current consumption Max. 100 mA
Storage temperature -20 °C ... +60 °C
Operating temperature 0 °C ... +50 °C
Designation Value • Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
Caution: Any changes or modifications not
expressly approved by the party responsible for
compliance could void the user's authority to
operate the equipment.
10.2 For UL
For use with Listed Personal Computers only!
10.3 UKCA
UK Authorised Representative:
Authorised Representative Service
The Old Methodist Chapel
Great Hucklow
SK17 8RG
UK
1 Raccordement au
PC et installation
du logiciel
1 Chargez le pilote, le logiciel et la documentation
d'utilisation pour la KC 1000 SC (6440640) depuis
notre site web www.cherry.de sous
Assistance > Téléchargement.
2 Contrôlez l'intégrité des cachetages comme
décrit dans la documentation d'utilisation.
3 En ce qui concerne l'utilisation du clavier en
toute sécurité, respectez les remarques
indiquées dans la documentation d'utilisation
ainsi que les instructions d'installation.
4 Suivez les instructions d'installation à l'écran.
5 Connectez la fiche USB du clavier au connecteur
USB de votre PC.
2 Utilisation du lecteur de
cartes à puce
• Introduisez la carte à puce dans la fente
correspondante avec la puce vers le bas et
dirigée vers l'avant.
3 Secure PIN Entry
Si votre application supporte cette fonction, le code
PIN n'est pas transmis au système mais pris en
charge par votre application et transmis
directement du pavé numérique du clavier
(alphanumérique et numérique) à la carte à puce.
Validez le PIN avec l'une des deux touches
"Entrée".
Vous pouvez interrompre la procédure à l'aide de la
touche "Echap" ou de la touche "+" du pavé
numérique.
Utilisez la touche "Retour arrière" ou la touche "–"
du pavé numérique pour corrigez votre saisie.
DEL État
La DEL DATA est
allumée en bleu
Tension sur la carte à
puce
La DEL DATA clignote
en bleu
Transfert de données
La DEL PIN est allumée
en rouge
Clavier en mode
Secure PIN Entry