Mitsubishi Electric PEH-RP250MYA Guida d'installazione

Categoria
Condizionatori d'aria a sistema split
Tipo
Guida d'installazione

Questo manuale è adatto anche per

Air-Conditioners
INDOOR UNIT
PEH-RP200, 250MYA
FOR INSTALLER
FÜR INSTALLATEURE
POUR L’INSTALLATEUR
PARA EL INSTALADOR
PER L’INSTALLATORE
VOOR DE INSTALLATEUR
FÖR INSTALLATÖREN
TIL MONTØREN
PARA O INSTALADOR
°π∞ ∆√¡ ∆∂áπ∫√ ∂°∫∞∆∞™∆∞™∏™
TES‹SATÇININ D‹KKAT‹NE
ДЛЯ СПЕЦИАЛИСТА ПО МОНТАЖУ
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D’INSTALLATION
Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
INSTALLATIONSMANUAL
Läs denna installationsmanual noga för säkert och korrekt bruk innan luftkonditioneringen installeras.
INSTALLATIONSMANUAL
Læs venligst denne installationsmanual grundigt, før De installerer airconditionanlægget, af hensyn til sikker og korrekt anvendelse.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
2
GB
D
F
SWI
NL
E
P
[Fig. 2.0.1]
A
B
B
C
C
A Air outlet
B Remote controller
C Joint pipe for R407C (Field piping connection)
* In case of PEH-RP200 only
2
3
200530
131 200 19932
20
PEH-RP250: 1440
PEH-RP200: 1240
20
200400
730
7525928
428500
1
2
3
A
A
C
D
B
B
PEH-RP250: 1480
PEH-RP200: 1280
PEH-RP250: 2080 PEH-RP200: 1880
1 When connecting air inlet
2 When installing the suspension fixtures prior to installation of the
indoor unit without inlet duct
3 When hanging the indoor unit directly without inlet duct
A Service space B Suspension bolt pitch
C Air inlet D Air outlet
[Fig. 3.2.1]
F
G
H
A
B
D
C
E
E
4
4.1
A Ceiling board
B Edge beam
C Tie beam
D Square timber for hanging the air conditioner
E Pitch
F Insert: 100 to 150 kg (1 piece) (field supply)
G M10 hanging bolt (field supply)
H Reinforcement
[Fig. 4.1.1] [Fig. 4.1.2]
3.2
[Fig. 3.2.2]
20
199200
562
13122
C
D
B
B
F
GH
E
I
PEH-RP250: 1580
PEH-RP200: 1380
PEH-RP250: 1480
PEH-RP200: 1280
E Top of the unit
F 4-ø12 suspension bolt holes
G Control box
H Drain pan
I Main body
5
5.1
A30
B
A
B
A
*1
A30
B
10
A
A
B
[Fig. 5.1.1] [Fig. 5.1.2] [Fig. 5.1.3]
A Unit body
B Lifting machine
A Nut
B Washer
A Be sure to attach a U-shaped washer (4 wash-
ers in total).
3
GB
D
F
SWI
NL
E
P
6.2
5.2
A
6
95
40
100
152 156
42
C
D
A
B
A Refrigerant pipe (liquid pipe)
B Refrigerant pipe (gas pipe)
C Drain pipe
D Joint pipe (Accessory part ) * Only for PEH-RP200
when connecting to R407C outdoor unit
[Fig. 5.2.1]
[Fig. 6.2.1]
A
A
E
C
F
B
D
7
7.1
A
H
A
C
A
E
G
B
E
D
F
[Fig. 7.1.1] [Fig. 7.1.2]
A Thermal insulation
B Pull out insulation
C Wrap with damp cloth
D Return to original position
E Ensure that there is no gap here
F Wrap with insulating tape
A Brazing
B Flare joint
C Gas pipe
D Liquid pipe
E Service port
F Indoor unit
G Outdoor unit
H Joint pipe (Accessory part ) * Only for PEH-RP200 when connecting to R407C outdoor unit
[Fig.7.1.3]
7.2
[Fig.7.2.1]
A
A Remove the cap
A
B
G
F
D
H
I
J
E
C
A Insulator
B Drain pipe R1
C Drain pan
D
>
=
70 mm
E
>
=
2 × F
>
=
70 mm
F
>
=
35 mm
G Downward slope 20 mm/m or more
H Drain trap
I The drain pipe should extend below this level.
J Open drain
8
F
A
B
D C
E
GG
E
B
C
D
A
12.5
25~100 mm
10 mm
[Fig.8.0.1]
A Air inlet B Air outlet
C Access door D Ceiling surface
E Canvas duct F Keep duct-work length 850 or more
G Connect common reference potential wire between duct-work to air conditioner
[Fig.8.0.2]
A Inlet duct flange B Inlet temperature sensor
C Sensor protection plate D Sensor fixture
E Inlet duct
A Level check
4
GB
D
F
SWI
NL
E
P
[Fig.8.0.3]
B
C
A
H
I
E
G
D
F
E
A
34
45
98
25
60
20
1000
PEH-RP200 : 1102
PEH-RP250 : 1302
PEH-RP200 : 31
PEH-RP250 : 66
PEH-RP200 : 120
PEH-RP250 : 220
250
380
A Inlet duct flange
B PEH-RP200: 8 × 130pitch = 1040
PEH-RP250: 9 × 130pitch = 1170
C PEH-RP200: 24-ø3 holes (Inlet duct mount holes)
PEH-RP250: 26-ø3 holes (Inlet duct mount holes)
D Top of the unit
E Outlet duct flange
F PEH-RP200, 250: 7 × 130pitch = 910
G PEH-RP200, 250: 22-ø3 holes (Outlet duct mount holes)
H PEH-RP200, 250: 2 × 130pitch = 260
I PEH-RP200, 250: 2 × 100pitch = 200
8
30
46
30
30120
83.5
C
A
B
D
(1)
9
9.1
[Fig.9.1.1]
A Remote controller pro-
file
B Required clearances
surrounding the re-
mote controller
C Temperature sensor
D Installation pitch
9.2
[Fig.9.2.1]
AB
TB6
A
B
A To TB5 on the indoor unit
B Terminal block TB6 in remote controller
No polarity
(2)
C Wall D Conduit
E Lock nut F Bushing
G Switch box H Remote controller cord
I Seal with putty
F
H
C
D
E
G
I
I
B-1.
B-2.
I
<A> For installation in the switch box: <B> For direct installation on the wall
select one of the following:
(3)
<A> For installation in the switch box <B> For direct installation on the wall
C Switch box for two pieces D Remote controller cord
E Cross-recessed, pan-head screw
G Seal the remote controller cord service entrance with putty
H Wood screw
H
D
E
D
C
G
9.3
[Fig.9.3.1]
(1) (2)
[Fig.9.3.2]
5
GB
D
F
SWI
NL
E
P
[Fig.11.2.1]
OFF
<SW4>
1
2
ON
A
B
C
D
A Stop
B Cooling
C Operation
D Heating
11.211
14.1
14
[Fig.14.1.1]
TB4
TB5
TB1
TB4
TB5
TB1 TB1
TB4
TB5
1
1
2
2
AA
BBB
CD
AFGE
E SW 1 - 3 ~ 6
ON
OFF
3456
A Outdoor unit
B Indoor unit
C Main remote controller
D Subordinate remote controller
E Standard 1:1 (Refrigerant address = 00)
F Refrigerant address = 01
G Refrigerant address = 02
10
J
L
B
I
KEF
HG
S1
S2
S3
S1
S2
S3
L1
L2
L3
N
1
2
C D
L
L1
L2
L3
N
C D
A
[Fig.10.0.1]
[Fig.10.0.3]
A
B
C
A For remote controller cables
B For outdoor unit connection
cables
C For power supply cables
[Fig.10.0.4]
A
B
C
A White connector (50 Pa) C01
B Red connector (150 Pa) C02
C Remove
J
L
B
I
KEF
HG
S1
S2
S3
S1
S2
S3
L1
L2
L3
N
1
2
C D
L
L1
L2
L3
N
C D
A
[Fig.10.0.2]
A Outdoor unit power supply
B Indoor fan motor power supply
C Earth leakage breaker
D Wiring circuit breaker or isolating switch
E Power supply wiring for outdoor unit
F Power supply wiring for indoor unit
G Outdoor unit H Indoor unit
I Connection wiring for indoor/outdoor units (polarity)
J Remote controller
K Connection wiring for indoor/remote controller (no polarity)
L Grounding
6
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
Contents
1. Safety precautions
1.1. Before installation and electric work
s Before installing the unit, make sure you read all the “Safety
precautions”.
s The “Safety precautions” provide very important points re-
garding safety. Make sure you follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to prevent danger of injury
or death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the
unit.
Symbols put on the unit
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts. (This symbol is
displayed on the main unit label.) <Color: yellow>
: Beware of electric shock. (This symbol is displayed on the main unit label.)
<Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
Warning:
Ask the dealer or an authorized technician to install the air conditioner.
- Improper installation by the user may result in water leakage, electric shock,
or fire.
For refrigerant R410A installation work, follow the instructions in the in-
stallation Manual and use tools and pipe components specifically made
for use with R410A refrigerant. The R410A refrigerant in the HFC system
is pressurized 1.6 times the pressure of usual refrigerants. If pipe com-
ponents not designed for R410A refrigerant are used and the unit is not
installed correctly, the pipe may burst and cause damage or injuries. In
addition, water leakage, electric shock, or fire may result.
Install the unit at a place that can withstand its weight.
- Inadequate strength may cause the unit to fall down, resulting in injuries.
Use the specified cables for wiring. Make the connections securely so
that the outside force of the cable is not applied to the terminals.
- Inadequate connection and fastening may generate heat and cause a fire.
Prepare for strong winds and earthquakes and install the unit at the speci-
fied place.
- Improper installation may cause the unit to topple and result in injury.
Always use an filter and other accessories specified by Mitsubishi Elec-
tric.
- Ask an authorized technician to install the accessories. Improper installation
by the user may result in water leakage, electric shock, or fire.
Never repair the unit. If the air conditioner must be repaired, consult the
dealer.
- If the unit is repaired improperly, water leakage, electric shock, or fire may
result.
Do not touch the heat exchanger fins.
- Improper handling may result in injury.
When handling this product, always wear protective equipment.
EG: Gloves, full arm protection namely boiler suit, and safety glasses.
- Improper handling may result in injury.
If refrigerant gas leaks during installation work, ventilate the room.
- If the refrigerant gas comes into contact with a flame, poisonous gases will
be released.
Install the air conditioner according to this Installation Manual.
- If the unit is installed improperly, water leakage, electric shock, or fire may
result.
Have all electric work done by a licensed electrician according to “Elec-
tric Facility Engineering Standard” and “Interior Wire Regulations” and
the instructions given in this manual and always use a special circuit.
- If the power source capacity is inadequate or electric work is performed im-
properly, electric shock and fire may result.
Securely install the outdoor unit terminal cover (panel).
- If the terminal cover (panel) is not installed properly, dust or water may enter
the outdoor unit and fire or electric shock may result.
When installing and moving the air conditioner to another site, do not
charge it with a refrigerant different from the refrigerant (R410A or R407C)
specified on the unit.
- If a different refrigerant or air is mixed with the original refrigerant, the refrig-
erant cycle may malfunction and the unit may be damaged.
If the air conditioner is installed in a small room, measures must be taken
to prevent the refrigerant concentration from exceeding the safety limit
even if the refrigerant leaks.
- Consult the dealer regarding the appropriate measures to prevent the safety
limit from being exceeded. If the refrigerant leak and cause the safety limit to
be exceeded, hazards due to lack of oxygen in the room could result.
When moving and reinstalling the air conditioner, consult the dealer or
an authorized technician.
- If the air conditioner is installed improperly, water leakage, electric shock, or
fire may result.
After completing installation work, make sure that refrigerant gas is not
leaking.
- If the refrigerant gas leaks and is exposed to a fan heater, stove, oven, or
other heat source, it may generate noxious gases.
Do not reconstruct or change the settings of the protection devices.
- If the pressure switch, thermal switch, or other protection device is shorted
and operated forcibly, or parts other than those specified by Mitsubishi Elec-
tric are used, fire or explosion may result.
To dispose of this product, consult your dealer.
The installer and system specialist shall secure safety against leakage
according to local regulation or standards.
- Following standards may be applicable if local regulation are not available.
Pay a special attention to the place, such as a basement, etc. where re-
frigeration gas can stay, since refrigeration is heavier than the air.
1. Safety precautions ...................................................................................... 6
1.1. Before installation and electric work .......................................... 6
1.2. Precautions for devices that use R410A or R407C refrigerant .. 7
1.3. Before getting installed .............................................................. 7
1.4. Before getting installed (moved) - electrical work ...................... 7
1.5. Before starting the test run ........................................................ 7
2. Indoor unit accessories ............................................................................... 7
3. Selecting an installation site ....................................................................... 8
3.1. Install the indoor unit on a ceiling strong enough to sustain
its weight ................................................................................... 8
3.2. Securing installation and service space .................................... 8
3.3. Combining indoor units with outdoor units ................................ 8
4. Fixing hanging bolts .................................................................................... 8
4.1. Fixing hanging bolts .................................................................. 8
5. Installing the unit ......................................................................................... 8
5.1. Hanging the unit body ............................................................... 8
5.2. Confirming the unit’s position and fixing hanging bolts ............. 9
6. Refrigerant pipe and drain pipe specifications ............................................ 9
6.1. Refrigerant pipe and drain pipe specifications .......................... 9
6.2. Refrigerant pipe, drain pipe and filling port ............................... 9
7. Connecting refrigerant pipes and drain pipes ............................................. 9
7.1. Refrigerant piping work ............................................................. 9
7.2. Drain piping work ..................................................................... 10
8. Duct work .................................................................................................. 10
9. Remote controller ..................................................................................... 10
9.1. Installing procedures ............................................................... 10
9.2. Connecting procedures ........................................................... 11
9.3. Fitting the upper case .............................................................. 11
9.4. Function selection ................................................................... 11
10. Electrical wiring ......................................................................................... 15
11. Test run ...................................................................................................... 16
11.1. Before test run ......................................................................... 16
11.2. Test run procedures ................................................................. 16
11.3. Self-check ................................................................................ 17
11.4. Remote controller check .......................................................... 18
12. Test run [for wireless remote controller] .................................................... 19
12.1. Before test run ......................................................................... 19
12.2. Self-check ................................................................................ 19
12.3. Test run method ....................................................................... 20
13. Troubleshooting ......................................................................................... 20
13.1. How to handle problems with the test run ............................... 20
13.2. The following occurrences are not problems or errors ............ 21
14. System control .......................................................................................... 21
14.1. System settings ....................................................................... 21
14.2. Examples of refrigerant system address setting ..................... 21
7
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
1.2. Precautions for devices that use R410A
or R407C refrigerant
Caution:
Use refrigerant piping made of phosphorus deoxidized copper. In addi-
tion, be sure that the inner and outer surfaces of the pipes are clean and
free of hazardous sulphur, oxides, dust/dirt, shaving particles, oils, mois-
ture, or any other contaminant. Use pipes with the specified thickness.
(Refer to the 7.1.) Note the following if reusing existing pipes that carried
R22 refrigerant.
- Replace the existing flare nuts and flare the flared sections again.
- Do not use thin pipes. (Refer to the 7.1.)
- Contaminants on the inside of the refrigerant piping may cause the refriger-
ant residual oil to deteriorate.
Store the piping to be used during installation indoors and keep both
ends of the piping sealed until just before brazing. (Store elbows and
other joints in a plastic bag.)
- If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and
compressor trouble may result.
Use ester oil, ether oil or alkylbenzene (small amount) as the refrigerator
oil to coat flares and flange connections.
- The refrigerator oil will degrade if it is mixed with a large amount of mineral
oil.
Use liquid refrigerant to fill the system.
- If gas refrigerant is used to seal the system, the composition of the refriger-
ant in the cylinder will change and performance may drop.
Do not use a refrigerant other than R410A or R407C.
- If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may
cause the refrigerator oil to deteriorate.
Use a vacuum pump with a reverse flow check valve.
- The vacuum pump oil may flow back into the refrigerant cycle and cause the
refrigerator oil to deteriorate.
Use the following tools specifically designed for use with R410A or R407C
refrigerant.
The following tools are necessary to use R410A or R407C refrigerant.
Contact your nearest dealer for any questions.
Do not use a charging cylinder.
- Using a charging cylinder may cause the refrigerant to deteriorate.
Be especially careful when managing the tools.
- If dust, dirt, or water gets in the refrigerant cycle, the refrigerant may deterio-
rate.
1.3. Before getting installed
Caution:
Do not install the unit where combustible gas may leak.
- If the gas leaks and accumulates around the unit, an explosion may result.
Do not use the air conditioner where food, pets, plants, precision instru-
ments, or artwork are kept.
- The quality of the food, etc. may deteriorate.
Do not use the air conditioner in special environments.
- Oil, steam, sulfuric smoke, etc. can significantly reduce the performance of
the air conditioner or damage its parts.
When installing the unit in a hospital, communication station, or similar
place, provide sufficient protection against noise.
- The inverter equipment, private power generator, high-frequency medical
equipment, or radio communication equipment may cause the air conditioner
to operate erroneously, or fail to operate. On the other hand, the air condi-
tioner may affect such equipment by creating noise that disturbs medical
treatment or image broadcasting.
2. Indoor unit accessories
The unit is provided with the following accessories:
[Fig. 2.0.1] (P.2)
<Accessory part position>
A Air outlet B Remote controller
C Joint pipe for R407C (Field piping connection)
* In case of PEH-RP200 only
Gauge manifold
Charge hose
Gas leak detector
Torque wrench
Flare tool
Size adjustment gauge
Vacuum pump adapter
Electronic refrigerant charging scale
Tools (for R410A or R407C)
Do not install the unit on a structure that may cause leakage.
- When the room humidity exceeds 80 % or when the drain pipe is clogged,
condensation may drip from the indoor unit. Perform collective drainage work
together with the outdoor unit, as required.
1.4. Before getting installed (moved) - elec-
trical work
Caution:
Ground the unit.
- Do not connect the ground wire to gas or water pipes, lightning rods, or
telephone ground lines. Improper grounding may result in electric shock.
Install the power cable so that tension is not applied to the cable.
- Tension may cause the cable to break and generate heat and cause a fire.
Install an earth leakage circuit breaker, as required.
- If an earth leakage circuit breaker is not installed, electric shock may result.
Use power line cables of sufficient current carrying capacity and rating.
- Cables that are too small may leak, generate heat, and cause a fire.
Use only a circuit breaker and fuse of the specified capacity.
- A fuse or circuit breaker of a larger capacity or a steel or copper wire may
result in a general unit failure or fire.
Do not wash the air conditioner units.
- Washing them may cause an electric shock.
Be careful that the installation base is not damaged by long use.
- If the damage is left uncorrected, the unit may fall and cause personal injury
or property damage.
Install the drain piping according to this Installation Manual to ensure
proper drainage. Wrap thermal insulation around the pipes to prevent
condensation.
- Improper drain piping may cause water leakage and damage to furniture
and other possessions.
Be very careful about product transportation.
- Only one person should not carry the product if it weighs more than 20 kg.
- Some products use PP bands for packaging. Do not use any PP bands for a
means of transportation. It is dangerous.
- Do not touch the heat exchanger fins. Doing so may cut your fingers.
- When transporting the outdoor unit, suspend it at the specified positions on
the unit base. Also support the outdoor unit at four points so that it cannot
slip sideways.
Safely dispose of the packing materials.
- Packing materials, such as nails and other metal or wooden parts, may cause
stabs or other injuries.
- Tear apart and throw away plastic packaging bags so that children will not
play with them. If children play with a plastic bag which was not torn apart,
they face the risk of suffocation.
1.5. Before starting the test run
Caution:
Turn on the power at least 12 hours before starting operation.
- Starting operation immediately after turning on the main power switch can
result in severe damage to internal parts. Keep the power switch turned on
during the operational season.
Do not touch the switches with wet fingers.
- Touching a switch with wet fingers can cause electric shock.
Do not touch the refrigerant pipes during and immediately after opera-
tion.
- During and immediately after operation, the refrigerant pipes are may be hot
and may be cold, depending on the condition of the refrigerant flowing through
the refrigerant piping, compressor, and other refrigerant cycle parts. Your
hands may suffer burns or frostbite if you touch the refrigerant pipes.
Do not operate the air conditioner with the panels and guards removed.
- Rotating, hot, or high-voltage parts can cause injuries.
Do not turn off the power immediately after stopping operation.
- Always wait at least five minutes before turning off the power. Otherwise,
water leakage and trouble may occur.
8
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
4.1. Fixing hanging bolts
(Use M10 hanging bolts. The bolts should be supplied in the field.)
(Give site of suspension strong structure.)
Hanging structure
Ceiling: The ceiling structure varies from building to one another. For detailed
information, consult your construction company.
1 Reinforcing the ceiling with additional members (edge beam, etc) must be re-
quired to keep the ceiling at level and to prevent the ceiling from vibrations.
2 Cut and remove the ceiling members.
3 Reinforce the ceiling members, and add other members for fixing the ceiling
boards.
For wooden construction
Use the tie beam (for one story building) or second-floor beam (for two story
building) as strength members.
4. Fixing hanging bolts
To hang the air-conditioner, use a hard square timber of more than 6 cm if the
distance between beams is less than 90 cm and a hard square timber of more
than 9 cm if the distance between beams is less than 180 cm.
[Fig. 4.1.1] (P.2)
A Ceiling board B Edge beam C Tie beam
D Square timber for hanging the air conditioner E Pitch
For reinforced concrete construction
As shown in the figure below, fix the hanging bolts, or use square timbers to fix
the hanging bolts.
[Fig. 4.1.2] (P.2)
F Insert: 100 to 150 kg (1 piece) (field supply)
G M10 hanging bolt (field supply) H Reinforcement
Product Weight (kg)
PEH-RP200MYA 70 kg
PEH-RP250MYA 80 kg
5. Installing the unit
5.1. Hanging the unit body
s Bring the indoor unit to an installation site as it is packed.
s To hang the indoor unit, use a lifting machine to lift and pass through the
hanging bolts.
s Install the indoor unit before ceiling work.
[Fig. 5.1.1] (P.2)
A Unit body B Lifting machine
* Two installation methods are available
<When hanging the indoor unit directly>
1. Attach a washer and nut(s) to each suspension bolt. (The washers and nuts
are to be supplied locally.)
2. Fit the indoor unit to each suspension bolt.
3. Make sure that the unit is positioned level, then tighten each nut.
[Fig. 5.1.2] (P.2)
A Nut B Washer
AB
When using inlet duct 100 or more 130 or more
When not using inlet duct 0 or more 30 or more
Nut (*1) is not required if distance A is 0.
<When installing the suspension fixture prior to installation of the indoor unit>
1. Loosen each suspension fixture bolt slightly, and remove the fixture and U-
shaped washers.
2. Adjust each suspension fixture bolt.
3. Attach a washer, nut and suspension fixture to each suspension bolt. (The
washers and nuts are to be supplied locally.)
4. Hook the indoor unit to the suspension fixtures.
5. Make sure that the unit is positioned level, then tighten each nut.
[Fig. 5.1.3] (P.2)
A Be sure to attach a U-shaped washer (4 washers in total).
AB
When using inlet duct 100 or more 130 or more
When not using inlet duct 25 or more 55 or more
Select a site with sturdy fixed surface sufficiently durable against the weight of
unit.
Before installing unit, the routing to carry in unit to the installation site should
be determined.
Select a site where the unit is not affected by entering air.
Select a site where the flow of supply and return air is not blocked.
Select a site where refrigerant piping can easily be led to the outside.
Select a site which allows the supply air to be distributed fully in room.
Do not install unit at a site with oil splashing or steam in much quantity.
Do not install unit at a site where combustible gas may generate, flow in, stag-
nate or leak.
Do not install unit at a site where equipment generating high frequency waves
(a high frequency wave welder for example) is provided.
Do not install unit at a site where fire detecter is located at the supply air side.
(Fire detector may operate erroneously due to the heated air supplied during
heating operation.)
When special chemical product may scatter around such as site chemical plants
and hospitals, full investigation is required before installing unit. (The plastic
components may be damaged depending on the chemical product applied.)
3.1. Install the indoor unit on a ceiling strong
enough to sustain its weight
Warning:
The unit must be securely installed on a structure that can sustain its weight.
If the unit is mounted on an unstable structure, it may fall down causing
injuries.
3. Selecting an installation site
3.2. Securing installation and service space
Select the optimum direction of supply airflow according to the configuration of
the room and the installation position.
As the piping and wiring are connected at the bottom and side surfaces, and
the maintenance is made at the same surfaces, allow a proper space properly.
For the efficient suspension work and safety, provide a space as much as
possible.
Service space
[Fig. 3.2.1] (P.2)
1 When connecting air inlet
2 When installing the suspension fixtures prior to installation of the indoor unit with-
out inlet duct
3 When hanging the indoor unit directly without inlet duct
A Service space B Suspension bolt pitch
C Air inlet D Air outlet
Suspension bolt pitch
[Fig. 3.2.2] (P.2)
E Top of the unit F 4-ø12 suspension bolt holes
G Control box H Drain pan I Main body
3.3. Combining indoor units with outdoor
units
For combining indoor units with outdoor units, refer to the outdoor unit installation
manual.
9
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
7.1. Refrigerant piping work
This piping work must be done in accordance with the installation manuals for
outdoor unit.
For constraints on pipe length and allowable difference of elevation, refer to
the outdoor unit manual.
The method of pipe connection is brazing connection.
Cautions on refrigerant piping
s Be sure to use non-oxidative brazing for brazing to ensure that no for-
eign matter or moisture enter into the pipe.
s Provide a metal brace to support the refrigerant pipe so that no load is
imparted to the indoor unit end pipe. This metal brace should be pro-
vided 50 cm away from the indoor unit’s brazing connection.
Warning:
Do not mix anything other than the specified refrigerant (R410A or R407C)
into the refrigerating cycle. Mixing air may cause the refrigerating cycle to
get abnormally high temperature, resulting in a burst.
Caution:
Install the refrigerant piping for the indoor unit in accordance with the
following.
1. Remove the cap.
[Fig. 7.1.1] (P.3)
A Remove the cap
2. Pull out the thermal insulation on the site refrigerant piping, braze the unit
piping, and replace the insulation in its original position.
Wrap the piping with insulating tape.
[Fig. 7.1.2] (P.3)
A Thermal insulation B Pull out insulation
C Wrap with damp cloth D Return to original position
E Ensure that there is no gap here F Wrap with insulating tape
Note:
Pay strict attention when wrapping the copper piping since wrapping the
piping may cause condensation instead of preventing it.
* Before brazing the refrigerant piping, always wrap the piping on the main
body, and the thermal insulation piping, with damp cloths to prevent heat
shrinkage and burning the thermal insulation tubing. Take care to ensure
that the flame does not come into contact with the main body itself.
Caution:
Refer to the 1.2. for precautions not included below on using air condi-
tioners with R410A or R407C refrigerant.
To avoid dew drops, provide sufficient antisweating and insulating work to the re-
frigerant and drain pipes.
When using commercially available refrigerant pipes, be sure to wind commer-
cially available insulating material (with a heat-resisting temperature of more than
100 °C and thickness given below) onto both liquid and gas pipes.
Be also sure to wind commercially available insulating material (with a form
polyethylene’s specific gravity of 0.03 and thickness given below) onto all pipes
which pass through rooms.
1 Select the thickness of insulating material by pipe size.
Pipe size Insulating material’s thickness
6.4 mm to 25.4 mm More than 10 mm
28.6 mm to 38.1 mm More than 15 mm
2 If the unit is used on the highest story of a building and under conditions of
high temperature and humidity, it is necessary to use pipe size and insulating
material’s thickness more than those given in the table above.
3 If there are customer’s specifications, simply follow them.
6. Refrigerant pipe and drain pipe specifications
6.1. Refrigerant pipe and drain pipe specifi-
cations
Item
Model
PEH-RP200MYA PEH-RP250MYA
Liquid pipe ø12.7* ø12.7
Gas pipe ø25.4 ø28.58
Liquid pipe ø9.52 ø12.7
Gas pipe ø25.4 ø28.58
Drain pipe R1 (Male screw)
* Joint pipe (Accessory part)
6.2. Refrigerant pipe, drain pipe and filling
port
[Fig. 6.2.1] (P.3)
A Refrigerant pipe (liquid pipe) B Refrigerant pipe (gas pipe)
C Drain pipe
D Joint pipe (Accessory part ) * Only for PEH-RP200 when connecting to R407C
outdoor unit
7. Connecting refrigerant pipes and drain pipes
Use C1220 copper phosphorus, for copper and copper alloy seamless
pipes, to connect the refrigerant pipes. Use refrigerant pipes with the
thicknesses specified in the table to the below. Make sure the insides of
the pipes are clean and do not contain any harmful contaminants such
as sulfuric compounds, oxidants, debris, of dust.
Do not use pipes thinner than those specified above.
Store the piping to be used during installation indoors and keep both
ends of the piping sealed until just before brazing.
- If dust, dirt, or water gets into the refrigerant cycle, the oil will deteriorate and
the compressor may fail.
Use ester oil, ether oil or alkylbenzene (small amount) as the refrigerator
oil to coat flares and flange connections.
- The refrigerant used in the unit is highly hygroscopic and mixes with water
and will degrade the refrigerator oil.
Do not use a leak detection additive.
Additional refrigerant charge
Take care not to allow dirt or cutting chips to enter the refrigerant pipes.
The refrigerant pipes must be kept warm, so take particular care to insulate
between refrigerant pipes and the gas pipe located inside the indoor unit, since
the gas pipe causes condensation during cooling operation.
When connecting the refrigerant pipes, make sure that the stop valve of the
outdoor unit is fully closed (as it was when shipped from the factory). After
connecting all the refrigerant pipes between the indoor and outdoor units, purge
air from the stop valve service port of the outdoor unit and service port of each
connecting pipe. Check that there is no air leakage from any pipe connection,
then fully open the stop valve of the outdoor unit. This will connect the refriger-
ant circuit between the indoor and outdoor units.
The refrigerant pipes must be as short as possible.
Flare and flange connections must be used for connection of the refrigerant
pipes.
The indoor and outdoor units must be connected with the refrigerant pipes.
[Fig. 7.1.3] (P.3)
A Brazing B Flare joint C Gas pipe
D Liquid pipe E Service port F Indoor unit
G Outdoor unit
H Joint pipe (Accessory part )
* Only for PEH-RP200 when connecting to R407C outdoor unit
Refrigerant pipe
(R407C)
Pipe size (mm)
Thickness (mm)
ø9.52
0.8
ø12.7
0.8
ø25.4
1.0
ø28.58
1.0
5.2. Confirming the unit’s position and fix-
ing hanging bolts
[Fig. 5.2.1] (P.3)
A Level check
s Use the gage supplied with the panel to confirm that the unit body and
hanging bolts are positioned in place. If they are not positioned in place,
it may result in dew drops due to wind leak. Be sure to check the positional
relationship.
s Use a level to check that the surface indicated by
AA
AA
A is at level. Ensure
that the hanging bolt nuts are tightened to fix the hanging bolts.
s To ensure that drain is discharged, be sure to hang the unit at level using
a level.
Caution:
Be sure to install the unit body at level.
Refrigerant pipe
(R410A)
10
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
8. Duct work
In connecting duct, insert canvas duct between unit and duct.
Use incombustible material for duct parts.
Provide full insulation to inlet duct flange, outlet duct flange and outlet duct to
prevent condensation.
Be sure to apply the air filter near the air inlet grille.
Before connecting an inlet duct, remove the air filter (supplied with the unit),
then install that filter in the inlet grille.
[Fig. 8.0.1] (P.3)
A Air inlet B Air outlet
C Access door D Ceiling surface
E Canvas duct F Keep duct-work length 850 or more
G Connect common reference potential wire between duct-work to air conditioner
Caution:
Outlet duct is 850 mm or more necessary to construct.
To connect the air conditioner main body and the duct for potential equali-
zation.
Inlet temperature sensor when an inlet duct is installed.
An inlet temperature sensor is installed on the inlet duct flange. Before con-
necting an inlet duct, this sensor must be removed and installed in the speci-
fied position.
[Fig. 8.0.2] (P.3)
A Inlet duct flange B Inlet temperature sensor
C Sensor protection plate D Sensor fixture
E Inlet duct
1 Pull out the sensor, and remove the sensor fixture and protection plate. (The
protection plate must be discarded.)
2 Connect the inlet duct.
3 Drill a sensor hole (ø12.5 dia.) on the side on the duct.
4 Assemble the sensor and fixture.
When pulling out the sensor, do not pull it by the lead wire. Doing so may result
in wire breakage.
Before connecting the inlet duct, make sure that the sensor, its fixture and
protection plate are removed.
The sensor removed in step 1 must be re-installed in the position specified in
the drawing. Installation of the sensor in an incorrect position may result in
malfunction.
Mount holes for outlet duct flange and inlet duct.
[Fig. 8.0.3] (P.4)
A Inlet duct flange
B PEH-RP200: 8 × 130 pitch = 1040
PEH-RP250: 9 × 130 pitch = 1170
C PEH-RP200: 24-ø3 holes (Inlet duct mount holes)
PEH-RP250: 26-ø3 holes (Inlet duct mount holes)
D Top of the unit
E Outlet duct flange
F PEH-RP200, 250: 7 × 130 pitch = 910
G PEH-RP200, 250: 22-ø3 holes (Outlet duct mount holes)
H PEH-RP200, 250: 2 × 130 pitch = 260
I PEH-RP200, 250: 2 × 100 pitch = 200
9. Remote controller
9.1. Installing procedures
(1) Select an installing position for the remote controller (switch box).
Be sure to observe the following precautions.
[Fig. 9.1.1] (P.4)
A Remote controller profile
B Required clearances surrounding the remote controller
C Temperature sensor D Installation pitch
1 The temperature sensors are located on both remote controller and indoor
unit. To use the temperature sensor on the remote controller, mainly use the
remote controller for temperature setting or room temperature detection. In-
stall the remote controller in such an area that can detect average room tem-
peratures, free of direct sunlight, airflow from the air conditioner, and other
such heating source.
2 In either case when the remote controller is installed in the switch box or on the
wall, provide the clearances indicated in the diagram.
Note:
Check that there is no electric wire left close to the remote controller sensor.
If any electric wire is near the sensor, the remote controller may fail to detect
a correct room temperature.
3 Procure the following parts locally:
Switch box for two pieces
Thin copper conduit tube
Lock nuts and bushings
(2) Seal the service entrance for the remote controller cord with putty to
prevent possible invasion of dew drops, water, cockroaches or worms.
<A> For installation in the switch box:
When the remote controller is installed in the switch box, seal the junction
between the switch box and the conduit tube with putty.
<B> For direct installation on the wall select one of the following:
B-1. To lead the remote controller cord from the back of the controller:
Prepare a hole through the wall to pass the remote controller cord (in order to
run the remote controller cord from the back), then seal the hole with putty.
B-2. To run the remote controller cord through the upper portion:
Run the remote controller cord through the cut-out upper case, then seal the
cut-out notch with putty similarly as above.
[Fig. 9.1.1] (P.4)
C Wall D Conduit E Lock nut
F Bushing G Switch box
H Remote controller cord I Seal with putty
(3) Install the lower case in the switch box or on the wall.
[Fig. 9.1.1] (P.4)
Indoor unit
Refrigerant
Joint outdoor unit
Refrigerant
Pipe size (mm)
R407C
Liquid side
Gas side
PEH-RP200
PUH-P200
ø12.7*
ø25.4
PEH-RP250
PUH-P250
ø12.7
ø28.58
Indoor unit
Refrigerant
Joint outdoor unit
Refrigerant
Pipe size (mm)
Liquid side
Gas side
PEH-RP200
PUHZ-RP200
ø9.52
ø25.4
PEH-RP250
PUHZ-RP250
ø12.7
ø28.58
R410A
Warning:
When installing or moving the air conditioner, use only the specified refrig-
erant (R410A or R407C) to charge the refrigerant lines. Do not mix it with any
other refrigerant and do not allow air to remain in the lines. Air enclosed in
the lines can cause pressure peaks resulting in a rupture and other hazards.
7.2. Drain piping work
[Fig. 7.2.1] (P.3)
A Insulator B Drain pipe R1
C Drain pan D
>
=
70 mm
E
>
=
2 × F
>
=
70 mm F
>
=
35 mm
G Downward slope 20 mm/m or more H Drain trap
I The drain pipe should extend below this level.
J Open drain
1. Ensure that the drain piping is downward (pitch of more than 20 mm/m) to the
outdoor (discharge) side.
2. Ensure that any crosswise drain piping is less than 20 m (excluding the differ-
ence of elevation). If the drain piping is long, provide metal braces to prevent it
from waving. Never provide any air vent pipe. Otherwise drain may be ejected.
3. Use a hard vinyl chloride pipe VP-25 (with an external diameter of 32 mm) for
drain piping.
4. Ensure that collected pipes are 10 cm lower than the unit bodys drain port.
5. Put the end of the drain piping in a position where no odor is generated.
6. Do not put the end of the drain piping in any drain where ionic gases are
generated.
* When connecting to R407C outdoor unit, use the joint pipe which is attached
to the indoor unit.
s Refer to the installation manual for details of the additional amount of
refrigerant for the outdoor unit.
11
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
<A> For installation in the switch box
C Switch box for two pieces D Remote controller cord
E Cross-recessed, pan-head screw
G Seal the remote controller cord service entrance with putty
<B> For direct installation on the wall
H Wood screw
Caution:
Do not over-tighten the screws to possible deformed or broken lower case.
Note:
Select a flat place for installation.
Be sure to use two or more locations for securing of the remote control-
ler in the switch box or on the wall.
9.2. Connecting procedures
The remote controller cord can be extended up to a maximum of 200 m. Use
electric wires or (two-core) cables of 0.3 mm
2
to 1.25 mm
2
for making connec-
tion of remote controller. Do not use multi-conductor cables to prevent possi-
ble malfunction of the unit.
[Fig. 9.2.1] (P.4)
(1) Connect the remote controller cord to the terminal block at the lower
case.
A To TB5 on the indoor unit
B Terminal block TB6 in remote controller
No polarity
[Function selection flowchart]
[1] Stop the air conditioner to start remote controller function selection mode. [2] Select from item1. [3] Select from item2. [4] Make the setting. (Details
are specified in item3) [5] Setting completed. [6] Change the display to the normal one. (End)
9.4. Function selection
<Wired remote controller type>
(1) Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed.
Item 1
1.Change Language
(CHANGE LANGUAGE)
2.Function limit
(FUNCTION
SELECTION)
3.Mode selection
(MODE SELECTION)
4.Display change
(DISP MODE SETTING)
Item 3 (Setting content)
Display in multiple languages is possible.
Setting the range of operation limit (operation lock)
Setting the use or non-use of automatic operation mode
Setting the temperature adjustable range (maximum, minimum)
Selecting main or sub remote controller
*
When two remote controllers are connected to one group, one controller must be set to sub.
Setting the use or non-use of clock function
Setting the timer type
Contact number display in case of error
Setting the telephone number
Setting the temperature unit (°C or °F) to display
Setting the use or non-use of the display of indoor (suction) air temperature
Setting the use or non-use of the display of Cooling or Heating display during
operation with automatic mode
Item 2
Language setting to display
(1)
Operation function limit setting (operation lock) (LOCKING FUNCTION)
(2) Use of automatic mode setting (SELECT AUTO MODE)
(3) Temperature range limit setting (LIMIT TEMP FUNCTION)
(1) Remote controller main/sub setting (CONTROLLER MAIN/SUB)
(2) Use of clock setting (CLOCK)
(3) Timer function setting (WEEKLY TIMER)
(4) Contact number setting for error situation (CALL.)
(1) Temperature display °C/°F setting (TEMP MODE °C/°F)
(2)
Suction air temperature display setting (ROOM TEMP DISP SELECT)
(3)
Automatic cooling/heating display setting (AUTO MODE DISP C/H)
(Hold down the E button and press the D button for two
seconds.)
* The display cannot be changed during the unit function
selection, the test run and the self diagnosis.
(Hold down the E button and press
the D button for two seconds.)
* The remote controller records the
setting that is made in this way.
Press the
G button.
See [4]-1
Item 3
(Setting content)
Item 1
Remote Controller Function
Selection Mode
Item 2
Mode selection
(MODE
SELECTION)
Normal display (Display when the
air condition is not running)
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
F
G
C
D
B
I
A
H
E
Change Language
(CHANGE LANGUAGE)
Function limit
(FUNCTION
SELECTION)
Display change
(DISP MODE
SETTING)
NOTE
Timer operation stops when the display for
remote controller function selection is changed
to the normal one.
Press the G button.
Press the E
button.
Press the
E button.
Press the
E button.
Press the
E button.
Press the
G button.
Press the
G button.
See [4]-2. (1)
See [4]-2. (2)
See [4]-2. (3)
See [4]-3. (1)
See [4]-3. (2)
See [4]-3. (3)
See [4]-3. (4)
See [4]-4. (1)
See [4]-4. (2)
See [4]-4. (3)
Dot display
The language that is selected in
CHANGE LANGUAGE mode
appears on this display. English is set
in this manual.
Press the D
button.
Press the D
button.
Press the D
button.
→→
Operation function limit setting (LOCKING FUNCTION)
Press the G button.
Temperature range limit setting (LIMIT TEMP FUNCTION)
Use of automatic mode setting (SELECT AUTO MODE)
Temperature display °C/°F setting (TEMP MODE °C/°F)
Press the G button.
Automatic cooling/heating display setting (AUTO MODE DISP C/H)
Suction air temperature display setting (ROOM TEMP DISP SELECT)
Remote controller main/sub setting (CONTROLLER MAIN/SUB)
Press the G button.
Timer function setting (WEEKLY TIMER)
Use of clock setting (CLOCK)
Contact number setting for error situation (CALL.)
Caution:
Do not use crimp-style terminals for connection to the remote controller
terminal block to eliminate contact with the boards and resultant trouble.
Prevent remote cord chips from getting into the remote controller. Elec-
tric shock or malfunction may result.
9.3. Fitting the upper case
[Fig. 9.3.1] (P.4)
(1) To remove the upper case, put a slotted screwdriver tip in the latches as
shown in the diagram then move the screwdriver in the direction of ar-
row.
(2) To install the upper case, put the upper latches (at two locations) first,
then fit the upper case into the lower case as illustrated.
[Fig. 9.3.2] (P.4)
Note:
Wiring hole for installing directly on the wall (or open wiring)
Cut off the shaded area from the upper case using a knife, nippers, etc.
Take out the remote control cord connected to the terminal block via this
portion.
Caution:
Do not move the screwdriver while inserting the tip far into the latches to
prevent broken latches.
Be sure to put the upper case securely in the latches by pressing it until
a snap sounds. Loosely inserted, the upper case may fall down.
Note:
The operating section is covered with a protective sheet. Before using the
unit, remember to remove the protective sheet.
12
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
[Detailed setting]
[4] -1. CHANGE LANGUAGE setting
The language that appears on the dot display can be selected.
Press the [
MENU] button to change the language.
1 Japanese (JP), 2 English (GB), 3 German (D), 4 Spanish (E), 5 Russian
(RU), 6 Italian (I), 7 Chinese (CH), 8 French (F)
[4] -2. Function limit
(1) Operation function limit setting (operation lock)
To switch the setting, press the [
ON/OFF] button.
1 no1: Operation lock setting is made on all buttons other than the [
ON/OFF]
button.
2 no2: Operation lock setting is made on all buttons.
3 OFF (Initial setting value):
Operation lock setting is not made.
* To make the operation lock setting valid on the normal screen, it is necessary to
press buttons (Press and hold down the [FILTER] and [
ON/OFF] buttons at
the same time for two seconds.) on the normal screen after the above setting is
made.
(2) Use of automatic mode setting
When the remote controller is connected to the unit that has automatic operation
mode, the following settings can be made.
To switch the setting, press the [
ON/OFF] button.
1 ON (Initial setting value):
The automatic mode is displayed when the operation mode is selected.
2 OFF:
The automatic mode is not displayed when the operation mode is selected.
(3) Temperature range limit setting
After this setting is made, the temperature can be changed within the set range.
To switch the setting, press the [
ON/OFF] button.
1 LIMIT TEMP COOL MODE:
The temperature range can be changed on cooling/dry mode.
2 LIMIT TEMP HEAT MODE:
The temperature range can be changed on heating mode.
3 LIMIT TEMP AUTO MODE:
The temperature range can be changed on automatic mode.
4 OFF (initial setting): The temperature range limit is not active.
* When the setting, other than OFF, is made, the temperature range limit setting
on cooling, heating and automatic mode is made at the same time. However, the
range cannot be limited when the set temperature range has not changed.
To increase or decrease the temperature, press the [
TEMP ( ) or ( )]
button.
To switch the upper limit setting and the lower limit setting, press the [
]
button. The selected setting will flash and the temperature can be set.
Settable range
Cooling/Dry mode: Lower limit: 19°C ~ 30°C Upper limit: 30°C ~ 19°C
Heating mode: Lower limit: 17°C ~ 28°C Upper limit: 28°C ~ 17°C
Automatic mode: Lower limit: 19°C ~ 28°C Upper limit: 28°C ~ 19°C
* The settable range varies depending on the unit to connect (Mr. Slim units, Free-
plan units, and intermediate temperature units)
[4] -3. Mode selection setting
(1) Remote controller main/sub setting
To switch the setting, press the [
ON/OFF] button.
1 Main: The controller will be the main controller.
2 Sub: The controller will be the sub controller.
(2) Use of clock setting
To switch the setting, press the [
ON/OFF] button.
1 ON: The clock function can be used.
2 OFF: The clock function cannot be used.
(3) Timer function setting
To switch the setting, press the [
ON/OFF] button (Choose one of the
followings.).
1 WEEKLY TIMER (Initial setting value):
The weekly timer can be used.
2 AUTO OFF TIMER: The auto off timer can be used.
3 SIMPLE TIMER: The simple timer can be used.
4 TIMER MODE OFF: The timer mode cannot be used.
* When the use of clock setting is OFF, the WEEKLY TIMER cannot be used.
(4) Contact number setting for error situation
To switch the setting, press the [
ON/OFF] button.
1 CALL OFF: The set contact numbers are not displayed in case of error.
2 CALL **** *** ****: The set contact numbers are displayed in case of error.
CALL_: The contact number can be set when the display is as shown
on the left.
Setting the contact numbers
To set the contact numbers, follow the following procedures.
Move the flashing cursor to set numbers. Press the [
TEMP. ( ) and ( )]
button to move the cursor to the right (left). Press the [
CLOCK ( ) and ( )]
button to set the numbers.
[4] -4. Display change setting
(1) Temperature display °C/°F setting
To switch the setting, press the [
ON/OFF] button.
1 °C: The temperature unit °C is used.
2 °F: The temperature unit °F is used.
(2) Suction air temperature display setting
To switch the setting, press the [
ON/OFF] button.
1 ON: The suction air temperature is displayed.
2 OFF: The suction air temperature is not displayed.
(3) Automatic cooling/heating display setting
To switch the setting, press the [
ON/OFF] button.
1 ON: One of Automatic cooling and Automatic heating is displayed under the
automatic mode is running.
2 OFF: Only Automatic is displayed under the automatic mode.
(2) Unit Function Selection
Set the functions of each indoor unit from the remote controller, as required. The functions of each indoor unit can be selected only from the remote controller.
Set the functions by selecting the necessary items from Table 1 and Table 2. (Default settings are also shown below)
Table 1. Itemized functions of the entire refrigerant system (select unit number 00 to 15)
Function
Power failure
automatic recovery
Indoor temperature
detection
LOSSNAY
connectivity
Power voltage
Settings
Not available
Available
Unit operating average
Set by units remote controller
Remote controllers internal sensor
Not Supported
Supported (unit is not equipped with outdoor-air intake)
Supported (unit is equipped with outdoor-air intake)
240 V
220 V, 230 V
Mode no. Setting no. Check Default settings
1
01
2
1
02 2
3
1
03 2
3
04
1
2
Remarks
Approx. 4-minute wait-period
after power is restored.
Note:
When the indoor unit functions were changed using the function selection after installation is complete, always indicate the set contents by entering or other
mark in the appropriate check field of Table 1 and Table 2.
Table 2. Itemized functions of the indoor unit (select unit numbers 01 to 04 or AL)
Function
Filter sign
Fan operation
during thermo off
in heating
operation
Fan operation
during thermo off
in cooling
operation
Settings
100 Hr
2500 Hr
No filter sign indicator
Mode no. Setting no. Check Default settings Remarks
1
07 2
3
When selecting fan operation
Stop, set setting no. of Mode
no. 02 in Table 1 to 3. Be sure
to place the remote controller
inside the room to be air-condi-
tioned so that it can monitor the
room temperature.
3
2
25
Operation
Stop
27
1
2
Operation
Stop
13
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
[Function selection flow]
First grasp the function selection flow. The following describes setting of Power voltage of Table 1 as an example.
(For the actual setting procedure, see [Setting procedure] 1 to 0.)
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
F
G
C
D
B
I
A
H
E
1 Check the function selection set contents.
5 Registration (Press button E.)
6 Mode No. Selection 04 (Power voltage)
7 Setting No. selection 2 (220 V, 230 V)
(Buttons F and G operation)
(Specified indoor unit
Fan operation)
3 Refrigerant address specification 00 (Outdoor unit specification)
(Unnecessary for single refrigerant system.)
4 Unit address No. specification 00 (Indoor unit specification)
(Buttons C and D operation)
End?
8 Register (Press button E.)
0 Ending function display (Press buttons A and B simultaneously.)
Change
refrigerant
address and unit
address No.?
9
YES
NO
2 Switch to the FUNCTION SELECTION mode.
(Press A and B simultaneously in the remote controller OFF state.)
YES
NO
[Procedure] (Set only when change is necessary.)
1 Check the set contents of each mode. When the set contents of a mode were changed by function selection, the functions of that mode also change.
Check the set contents as described in steps 2 to 7 and change the setting based on the entries in the Table 1 and Table 2. (Refer default settings, when change the
setting)
2 Set the remote controller to Off.
Press and hold down the A [FILTER] and B [TEST] buttons at the same time
for two seconds or longer.
FUNCTION SELECTION blinks for a while, then the remote controller display
changes to the display shown below.
3 Set the outdoor unit refrigerant address No.
When the C [
CLOCK ( ) and ( )] buttons are pressed, the refrigerant
address No. decreases and increases between 00 and 15. Set it to the refriger-
ant address No. whose function you want to select.
(This step is unnecessary for single refrigerant system.)
* If the remote controller enters the OFF state after the FUNCTION SELECTION and room temperature displays
have flashes for two seconds, communication is
probably abnormal. Make sure there are no noise sources near the transmission line.
Note:
If you make a mistake during operation, end function selection by step
??
??
? and repeat selection from step
22
22
2.
Refrigerant address display
4 Set the indoor unit address No.
Press the D [
ON/OFF] button. The unit address No. display “– –” flashes.
When the C [
CLOCK ( ) and ( )] buttons are pressed, the unit address
No. changes in 00 01 02 03 04 AL order. Set it to the unit address
No. of the indoor unit whose functions you want to set.
* When setting mode 01 to 04, set the unit address No. to 00.
* When setting modes 07, 25, 27:
When setting for each indoor unit, set the unit address No. to 01-04.
When batch setting for all indoor units, set the unit address No. to AL.
Unit address No. display
5 Refrigerant address and unit address No. registration
Press the E [
] button. The refrigerant address and unit address No.
are registered.
After a while, the mode No. display “– –” flashes.
* When
flashes at the room temperature display, the selected refrigerant
address is not in the system.
When F is displayed at the unit address No. display, and when it flashes to-
gether with the refrigerant address display, the selected unit address No. does
not exist. Correctly set the refrigerant address and unit address No. by repeat-
ing steps 2 and 3.
When registered using the E [ ] button, the registered indoor unit
begins fan operation. When you want to know the location of the indoor units of
the unit address No. whose functions were selected, check here. When the unit
address No. is 00 or AL, all the indoor units of the selected refrigerant address
perform the fan operation.
Ex) When refrigerant address 00, unit address No. = 01 registered
* When grouping by different refrigerant systems and an indoor unit other than
the specified refrigerant address performs the fan operation, the refrigerant
address set here is probably duplicated.
Recheck the refrigerant address at the outdoor unit DIP switches.
Mode No. display
Outdoor unit
Indoor unit
Refrigerant address 00
Unit address
No. 01
Fan operation
Registration
Remote Controller
14
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
<Wireless remote controller type>
Changing the power voltage setting
Be sure to change the power voltage setting depending on the voltage used.
1 Go to the function select mode
Press the
CHECK
button F twice continuously.
(Start this operation from the status of remote controller display turned off.)
CHECK
is lighted and 00 blinks.
Press the temp
button C once to set 50. Direct the wireless remote controller
toward the receiver of the indoor unit and press the
h
button A.
2 Setting the unit number
Press the temp
button C and D to set the unit number 00. Direct the
wireless remote controller toward the receiver of the indoor unit and press the
min
button B.
3 Selecting a mode
Enter 04 to change the power voltage setting using the
C and D buttons.
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
h
button A.
Current setting number: 1 = 1 beep (one second)
2 = 2 beeps (one second each)
3 = 3 beeps (one second each)
4 Selecting the setting number
Use the
C and D buttons to change the power voltage setting to 02 (220 V,
230 V). Direct the wireless remote controller toward the sensor of the indoor unit
and press the
h
button A.
5 To select multiple functions continuously
Repeat steps 3 and 4 to change multiple function settings continuously.
6 Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and press
the
button E.
Note:
Whenever changes are made to the function settings after construction or
maintenance, be sure to record the added functions with an
”, in the
“Check” column provided on the chart.
6 Mode No. selection
Select the mode No. you want to set with the F [
TEMP. ( ) and ( )] buttons. (Only the settable mode numbers can be selected.)
7 Select the setting contents of the selected mode.
When the G [
MENU] button is pressed, the current setting No. flashes.
Use this to check the currently set contents.
8 The contents set at steps 3 to 7 are registered.
When the E [
] button is pressed, the mode No. and setting No. flash and registration begins. The flashing mode No. and setting No. change to a steady light
and setting ends.
* When “– –” appears at the mode No. and setting No. displays and
flashes at the room temperature display, communication is probably abnormal.
Make sure there are no noise sources near the transmission line.
9 To select more functions, repeat steps 3 to 8.
0 End function selection.
Press and hold down the A [FILTER] and B [TEST] buttons at the same time for two seconds or longer.
After a while, the function selection display disappears and the remote controller returns to the air conditioner off display.
* Do not operate the air conditioner from the remote controller for 30 seconds after the end of function selection.
Note:
When the functions of an indoor unit were changed by function selection after the end of installation, always indicate the set contents by entering a or other
mark in the appropriate check field of Table 1 and Table 2.
Mode No. 04 = Power voltage
Mode No. display
Setting No. display
Setting No. 1 = 240 V
Setting No. 2 = 220 V, 230 V
Select the setting No. using the F [ TEMP. ( ) and ( )] buttons.
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
CHECK
E
C,D
F
A
B
2
4
CHECK
CHECK
CHECK
CHECK
1
3
15
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
10. Electrical wiring
Precautions on electrical wiring
Warning:
Electrical work should be done by qualified electrical engineers in accord-
ance with “Engineering Standards For Electrical Installation” and supplied
installation manuals. Special circuits should also be used. If the power cir-
cuit lacks capacity or has an installation failure, it may cause a risk of elec-
tric shock or fire.
1. Be sure to take power from the special branch circuit.
2. Be sure to install an earth leakage breaker to the power.
3. Install the unit to prevent that any of the control circuit cables (remote control-
ler, transmission cables) is brought in direct contact with the power cable out-
side the unit.
4. Ensure that there is no slack on all wire connections.
5. Some cables (power, remote controller, transmission cables) above the ceiling
may be bitten by mouses. Use as many metal pipes as possible to insert the
cables into them for protection.
6. Never connect the power cable to leads for the transmission cables. Otherwise
the cables would be broken.
7. Be sure to connect control cables to the indoor unit, remote controller, and the
outdoor unit.
8. Put the unit to the ground on the outdoor unit side.
9. Be sure to connect between the control cable terminal block of the outdoor unit
and that of the indoor unit. (Cables have polarity, so make sure that they are
connected according to the terminal numbers.)
10. Fix power source wiring to control box by using buffer bushing for tensible force
(PG connection or the like). Connect control wiring to control terminal bed
through the knockout hole of control box using ordinary bushing.
In case of A-control wiring there is high voltage potential on the S3 terminal
caused by electrical circuit design that has no electrical insulation between
power line and communication signal line. Therefore, please turn off the main
power supply when servicing. And do not touch the S1, S2, S3 terminals
when the power is energized. If isolator should be used between indoor unit
and outdoor unit, please use 3-potes type.
Caution:
Be sure to put the unit to the ground on the outdoor unit side. Do not con-
nect the earth cable to any gas pipe, water pipe, lightening rod, or telephone
earth cable. Incomplete grounding may cause a risk of electric shock.
<Indoor unit controller board power supplied
from outdoor unit>
The following connection pattern is available when connecting to PUH-P and PUHZ-
RP outdoor unit.
[Fig. 10.0.1] (P.5)
A Outdoor unit power supply
B Indoor fan motor power supply
C Earth leakage breaker
D Wiring circuit breaker or isolating switch
E Power supply wiring for outdoor unit
F Power supply wiring for indoor unit
G Outdoor unit H Indoor unit
I Connection wiring for indoor/outdoor units (polarity)
J Remote controller
K Connection wiring for indoor/remote controller (no polarity)
L Grounding
* Affix a label A that is included with the manuals near each wiring diagram for
the indoor and outdoor units.
[Wiring example] (For metal piping)
* The grounding wire must be of the same diameter as the power cable wires.
[Selecting earth leakage breaker (NV)]
To select NF or NV instead of a combination of Class B fuse with switch, use the
following:
In the case of Class B fuse rated 15 A
NV is a product name of MITSUBISHI.
Power supply cords of appliances shall not be lighter than design 245 IEC 53
or 227 IEC 53.
Indoor unit/outdoor unit connecting cords shall not be lighter than design 245
IEC 57.
A switch with at least 3 mm contact separation in each pole shall be provided
by the Air conditioner installation.
The connection wiring between the outdoor and indoor units can be extended
up to a maximum of 80 m.
If 4 mm
2
used and S3 separated, Max. 50 m.
If 6 mm
2
used and S3 separated, Max. 80 m.
Caution:
Do not use anything other than the correct capacity breaker and fuse. Using
fuse, wire or copper wire with too large capacity may cause a risk of mal-
function or fire.
<Indoor unit controller board power supplied
from indoor unit>
The following connection pattern is available when connecting to PUHZ-RP out-
door unit only.
[Fig. 10.0.2] (P.5)
A Outdoor unit power supply
B Indoor fan motor power supply
C Earth leakage breaker
D Wiring circuit breaker or isolating switch
E Power supply wiring for outdoor unit
F Power supply wiring for indoor unit
G Outdoor unit H Indoor unit
I Connection wiring for indoor/outdoor units (polarity)
J Remote controller
K Connection wiring for indoor/remote controller (no polarity)
L Grounding
* Affix a label B that is included with the manuals near each wiring diagram for
the indoor and outdoor units.
If the indoor unit controller board power supplied from indoor unit, refer to the table
at the below. Change the indoor unit electrical box wiring refering to the figure
below and the DIP switch settings of the outdoor unit control board.
15 A
NV100-SW
15 A
30 mA 0.1s or less
Fuse (class B)
Earth leakage
breaker ELB
(with over-load protection)
Breaker
Capacity
Remote controller
cable
Cable or wire of
0.3 ~ 1.25 mm
2
(max. DC 12 V)
Fuse
15 A
15 A
15 A
15 A
Power Cable
1.5 mm
2
or thicker
1.5 mm
2
or thicker
PEH-RP200MYA
PEH-RP250MYA
* There are two types of labels (labels A and B). Affix the appropriate labels to
the units according to the wiring method.
Indoor unit electrical box connector
connection change
Label affixed near each wiring diagram
for the indoor and outdoor units
Outdoor unit DIP switch settings (when
indoor unit controller board power sup-
plied from indoor unit only)
Indoor unit specifications
Required
Required
ON
OFF 1 2
(SW8)
3
16
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
For this wiring connection method, indoor and outdoor unit connection (S2,
S3) wiring thickness can be a minimum of 0.3 mm
2
and wiring connection can
be extended up to a maximum of 120 m.
Location of cable holes
[Fig. 10.0.3] (P.5)
A For remote controller cables
B For outdoor unit connection cables C For power supply cables
Switching the external static pressure
The unit has been set at the factory so that the standard amount of air is
provided when the static pressure outside the unit is 50 Pa. However, it is
possible to change the motor torque so that the standard amount of air is
provided when the static pressure outside the unit is 150 Pa. This can be done
by removing the white connector and connecting the red one (both connectors
are provided inside the control box) as shown below.
[Fig. 10.0.4] (P.5)
A White connector (50 Pa) C01 B Red connector (150 Pa) C02
C Remove
S1
S2
S3
CO3 CO4
CO4
S1
S2
S3
L1
L2
L3
N
CO4 CO3
CO4
L1
L2
L3
N
Connectors (connections when shipped
from the factory are for indoor unit
controller board power supplied from
outdoor unit)
If the indoor unit
controller board
power supplied from
indoor unit, change
the connections of
the connectors as
shown in the following
figure.
Indoor unit controller board power supplied
from outdoor unit (when shipped from factory)
Indoor unit
controller
board
Connectors
Indoor unit
controller
board
Indoor unit controller board power
supplied from indoor unit
Fan motor
Fan motor
ON/OFF
TEMP.
˚C
˚C
CENTRALLY CONTROLLED
indicator
11.1. Before test run
The test run can be carried out either from the outdoor unit or the indoor unit.
1. Checklist
After the installation, piping setup, and wiring of the indoor and outdoor units is
complete, check that refrigerant is not leaking, the power and control wires are
not loose, and the poles are not reversed.
Use a 500 V insulation resistance tester to make sure that the resistance be-
tween the power terminal and the ground is 1.0 M or more. If it is less than
1.0 M, do not operate the unit. * Absolutely do not touch the tester to indoor/
outdoor connection terminals S1, S2, and S3. An accident could occur.
Make sure there is no malfunction in the outdoor unit. (If there is a malfunction,
you can diagnose it using LED1 on the board.)
Check that the ball valve is fully open on both the liquid and gas ends.
Check the electrical power phase. If the phase is reversed, the fan may rotate
in the wrong direction or stop, or unusual sounds may be produced.
Starting at least 12 hours before the test run, send current through the
crankcase heater. (If the current is running for a shorter period of time,
damage to the compressor could result.)
For specific models requiring changing of settings for higher ceilings or selec-
tion of power supply ON/OFF capability, make proper changes referring to the
description for Selection of Functions through Remote Controller.
After the above checks are complete, carry out the test run as indicated in the
following outline.
11.2. Test run procedures
1) Indoor unit
Operating procedures
1 Turn on the main power supply
While the display on the remote controller indicates
, the remote controller
is disabled. Turn off the
indicator before using the remote controller.
2 Press the [TEST] button twice successively within three seconds. Test
run starts.
TEST RUN and OPERATION MODE are displayed alternately.
3 Press [
] button
Cooling/drying mode: Cool air should start to blow.
Heating mode: Warm air should start to blow (after a while).
11. Test run
4 Check the outdoor unit fan for correct running
The outdoor unit features automatic capacity control to provide optimum fan
speeds. The fan keeps running at a low speed to meet the current outside air
condition unless it exceeds its available maximum power. Then, in actuality,
the fan may stop or run in the reverse direction depending on the outside air,
which does not mean malfunction.
5 Press the [
ON/OFF] button to reset the test run in progress
The test run will be automatically shut down after two hours in response to the
AUTO STOP setting of two hours on the timer.
During the test run, the room temperature display shows the indoor unit tubing
temperatures.
In the case of the test run, the OFF timer will activate, and the test run will
automatically stop after two hours.
The room temperature display section shows the control temperature for the
indoor units during the test run.
Check that all the indoor units are running properly for simultaneous twin and
triple operation.
Malfunctions may not be displayed even if the wiring is incorrect.
6 Register a telephone number
The telephone number of the repair shop, sales office, etc., to contact if an
error occurs can be registered in the remote controller. The telephone number
will be displayed when an error occurs.
For registration procedures, refer to 9.4 Function selection of remote control-
ler.
˚C
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
Operation mode display
TEST RUN and OPERATION MODE are
displayed alternately.
Timer stops test run after two hours.
Piping temperature display
Stop test run by pressing the [ ON/OFF] button.
During test run, the RUN lamp remains on.
[TEST] button
[ ] button
(*1)
After turning ON the power, the system will go into startup mode, and the remote
controller operation lamp (green) and the display sections PLEASE WAIT will
flash. Also, in the case of the indoor substrate LEDs, LED 1 and LED 2 light up
(when address is 0) or become dim (when address is not 0), and LED 3 flashes. In
the case of the outdoor substrate LED display,
and are displayed
alternatively at 1-second intervals.
If one of the above operations does not function correctly, the following causes
should be considered, and if applicable, dealt with. (The following symptoms
have been determined under test run mode. Note that startup in the chart
means the *1 display above.)
ORANGE
CND
ORANGE
CND
17
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
Symptoms
Remote Controller Display Outdoor Substrate LED Display
Cause
Remote controller is displaying PLEASE WAIT, and
operation is not possible.
After power is turned ON, PLEASE WAIT is dis-
played for 3 mins., then error code is displayed.
Power is turned ON, and EE or EF are displayed
after PLEASE WAIT is displayed.
Display messages do not appear even when remote
controller operation switch is turned ON (operation
lamp does not light up).
Operation display appears but soon disappears even
when remote controller operations are executed.
After startup display, 00 is dis-
played (correct operation).
After startup display, error code is
displayed.
After startup display, F1 (negative
phase) is displayed.
After startup display, 00 or EE is
displayed (EE is displayed when a
test run is made).
After startup display, EA (error for
number of units) or Eb (unit number
error) is displayed.
After startup display, 00 is dis-
played (correct operation).
After startup display, 00 is dis-
played (correct operation).
After startup display, 00 is dis-
played (correct operation).
After power is turned ON, system startup lasts for about 2 mins., and
PLEASE WAIT is displayed (correct operation).
Outdoor units safeguard installation connector is open.
Negative phase and open phase of outdoor units power terminal board
(Single phase: L, N,
/triple phase: L1, L2, L3, N, )
Incorrect connection of outdoor terminal board (Single phase: L, N,
/
triple phase: L1, L2, L3, N, grounding and S1, S2, S3)
Outdoor unit and indoor unit construction differ
Wiring for the indoor and outdoor unit is not connected correctly. (Polarity
is wrong for S1, S2, S3)
Remote controller transmission wire short
There is no outdoor unit for address 0 (address is something other than
0).
Remote controller transmission wire burnout
After cancellation of function selection, operation is not possible for about
30 secs. (correct operation).
2) Outdoor unit
1) Check Items
After installation of indoor and outdoor units, and piping and electric wiring
work, check that the unit is free from leaks of refrigerant, loosened connec-
tions, and incorrect polarity.
Check that there is no negative phase and open phase. (The F1 message for
negative phase and the F2 message for open phase will flash at LED 1 on the
outdoor substrate. If this happens, rewire correctly.)
Measure the impedance between power terminals (Single phase: L, N,
/
triple phase: L1, L2, L3, N,
) and the ground with a 500 V Megger and check
that it is 1.0 M or more. Do not operate the equipment if measurement is less
than 1.0 M. * Never conduct this operation on the outdoor connection wiring
terminals (S1, S2, S3) as this causes damage.
When there is no error at the outdoor unit.
(If there is an error at the outdoor unit, it can be evaluated at LED 1 [digital
display] of the outdoor substrate.)
The stop valves are open both the liquid and gas sides.
After checking the above, execute the test run in accordance with the follow-
ing.
2) Test run start and finish
Operation from the indoor unit
Execute the test run using the installation manual for the indoor unit.
Operation from the outdoor unit
Execute settings for test run start, finish and operation mode (cooling, heating)
using the DIP switch SW 4 on the outdoor substrate.
[Fig. 11.2.1] (P.5)
A Stop B Cooling
C Operation D Heating
1 Set the operation mode (cooling, heating) using SW 4-2
2 Turn ON SW 4-1, The operation mode for SW 4-2 will be adhered to, and
the test run will commence
3 Turn OFF SW 4-1 to finish the test run
There may be a faint knocking noise emitted from the proximity of the fan
during the test run. This is torque fluctuation occurring due to control of fan
revolutions. There is no problem with the product.
Note:
The SW 4-2 operation mode cannot be changed during the test run. (To change
test run mode, stop the equipment with SW 4-1, change the operation mode,
then restart test run with SW 4-1.)
If the 2-hour timer is set, the test run will stop automatically after 2 hours.
During the test run, the room temperature display on the indoor unit will indi-
cate the temperature of the indoor unit piping.
* Press the remote controllers CHECK button twice consecutively to be able to run a self-check. See the chart below for content of error code displays.
LCD Nonconformity Content
E6 ~ EF Signal error between indoor and outdoor
units
- - - - No error history
FFFF No relevant unit
LCD Nonconformity Content LCD Nonconformity Content
P8 Tube temperature error
P9 Tube (2-phase tube) sensor error
U0 ~ UP Outdoor unit nonconformity
F1 ~ FA Outdoor unit nonconformity
E0 ~ E5 Signal error between remote controller and
indoor unit
P1 Suction sensor error
P2 Tubing (liquid) sensor error
P4 Drain sensor error
P5 Drain overflow safeguard operation
P6 Freezing/overheating safeguard operation
See the chart below for details of the LED displays (LED 1, 2, 3) on the indoor substrate.
LED 1 (microcomputer power supply) Displays the ON/OFF of power for control. Check that this is lit during normal use.
LED 2 (remote controller feed) Displays the ON/OFF of feed to wired remote controller. Is only lit for indoor unit linked to outdoor unit with address 00.
LED 3 (indoor and outdoor signals) Displays signal between indoor and outdoor units. Check that this is flashing during normal use.
11.3. Self-check
Retrieve the error history of each unit using the remote controller.
1 Switch to the self check mode.
When the H [CHECK] button is pressed twice successively within three sec-
onds, the display shown below appears.
2 Set the address or refrigerant address No. you want to self check.
When the F [
TEMP. ( ) and ( )] buttons are pressed, the address de-
creases and increases between 01 and 50 or 00 and 15. Set it to the address
No. or refrigerant address No. you want to self check.
Approximately three seconds after the change operation, the self check refrig-
erant address changes from flashing to a steady light and self check begins.
Self check address or self check refrigerant address
18
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
3 Self check result display <Error history> (For the contents of the error code, refer to 13. Troubleshooting, error code list.)
4 Error history reset
The error history is displayed in 3 Self check results display.
5 Self check reset
There are the following two ways of resetting self check.
Press the H [CHECK] button twice successively within three seconds Resets self check and returns to the state before self check.
Press the I [
ON/OFF] button Self check resets and indoor units stop.
(When operation is prohibited, this operation is ineffective.)
Error code 4 digits or error code 2 digits
Address 3 digits or unit address No. 2 digits
<When opposite side does not exist>
<When there is no error history>
ERROR CODE
ERROR CODE ERROR CODE
ERROR CODE ERROR CODE
ERROR CODE
When the D [ MENU] button is pressed twice successively within three sec-
onds, the self check address or refrigerant address flashes.
When the error history was reset, the display shown below appears.
When error history reset failed, the error contents are displayed again.
11.4. Remote controller check
If operation cannot be carried out from the remote controller, use this function to diagnose the remote controller.
ERROR CODE
Power mark
When the A [FILTER] button is pressed, remote controller check begins.
When remote controller is faulty
(Error display 1) NG flashes Remote controller send/receive circuit abnormal
Remote controller switching is necessary.
(Error display 3) ERC and data error count are displayed Data error generation
Data error count is the difference between the number of bits of remote controller
send data and the number of bits actually sent to the transmission line. In this case,
the send data was disturbed by the noise, etc. Check the transmission line.
Send data on transmission line
When data error count is 02
Remote controller send data
1 First check the power mark.
When normal voltage (DC12V) is not applied to the remote controller, the power
mark goes off.
When the power mark is off, check the remote controller wiring and the indoor
unit.
2 Switch to the remote controller check mode.
When the H [CHECK] button is held down for five seconds or longer, the dis-
play shown below appears.
3 Remote controller check result
When remote controller is normal
Since there is no problem at the remote controller, check for other causes.
When the problem is other than the checked remote controller
(Error code 2) E3 6833 6832 flash Cannot send
There is noise on the transmission line, or the indoor unit or another remote con-
troller is faulty. Check the transmission line and the other remote controllers.
4 Remote controller check reset
When the H [CHECK] button is held down for five seconds or longer, remote controller check resets and the PLEASE WAIT and RUN lamp flash. Approximately 30
seconds later, the remote controller returns to the state before remote controller check.
19
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
12. Test run [for wireless remote controller]
12.1. Before test run
ss
ss
s After completing installation and the wiring and piping of the indoor and
outdoor units, check for refrigerant leakage, looseness in the power sup-
ply or control wiring, and wrong polarity.
ss
ss
s Use a 500-volt megohmmeter to check that the resistance between the
power supply terminals and ground is at least 1.0 M
.
ss
ss
s Do not carry out this test on the control wiring (low voltage circuit) termi-
nals.
Warning:
Do not use the air conditioner if the insulation resistance is less than
1.0 M
.
Caution:
The compressor will not operate unless the power supply phase connection
is correct.
12.2. Self-check
1 Turn on the power.
2 Press the
CHECK
button twice.
(Start this operation from the status of re-
mote controller display turned off.)
A
CHECK
begins to light.
B 00 begins to blink.
3 While pointing the remote controller toward
the unit’s receiver, press the
h
button.
The check code will be indicated by the
number of times that the buzzer sounds
from the receiver section and the number
of blinks of the operation lamp.
4 Press the ON/OFF button to stop the self-
check.
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
CHECK
2
4
A
3
B
For description of each check code, refer to the following table.
1 Check code Symptom 2 Buzzer sound 3 OPE LED
P1 Intake sensor error Single beep × 1 Lit for 1 sec. × 1
P2 Pipe sensor error Single beep × 2 Lit for 1 sec. × 2
P4 Drain sensor error Single beep × 4 Lit for 1 sec. × 4
P5 Drain pump error Single beep × 5 Lit for 1 sec. × 5
P6 Freezing / Overheating safeguard operation Single beep × 6 Lit for 1 sec. × 6
P8 Pipe temperature error Single beep × 8 Lit for 1 sec. × 8
P9 TH5 sensor error Single beep × 2 Lit for 1 sec. × 2
U0UP Outdoor unit error Double beep × 1 Lit for 0.4 sec. + 0.4 sec. × 1
F1FA Outdoor unit error Double beep × 1 Lit for 0.4 sec. + 0.4 sec. × 1
E0E5 Signal error between remote controller and indoor units Sounds other than above Lights other than above
E6EF Communication error between indoor and outdoor units Sounds other than above Lights other than above
No alarm history No sound Not lit
F F F F No unit Triple beep Not lit
On wireless remote controller
2 The continuous buzzer sounds from receiving section of indoor unit.
3 Blink of operation lamp
On wired remote controller
1 Check code displayed in the LCD.
If the unit cannot be operated properly after the above test run has been performed, refer to the following table to remove the cause.
Symptom
Cause
Wired remote controller LED 1, 2 (PCB in outdoor unit)
PLEASE WAIT
PLEASE WAIT Error code
Display messages do not appear even
when operation switch is turned ON
(operation lamp does not light up).
For about 2
minutes following
power-on
After about 2
minutes has
expired following
power-on
After LED 1, 2 are lighted, LED 2 is turned off,
then only LED 1 is lighted. (Correct operation)
Only LED 1 is lighted. LED 1, 2 blink.
Only LED 1 is lighted. LED 1 blinks twice,
LED 2 blinks once.
For about 2 minutes following power-on, operation of the
remote controller is not possible due to system start-up.
(Correct operation)
Connector for the outdoor units protection device is not
connected.
Reverse or open phase wiring for the outdoor units power
terminal block (L1, L2, L3)
Incorrect wiring between indoor and outdoor units (incor-
rect polarity of S1, S2, S3)
Remote controller wire short
On the wireless remote controller with condition above, following phenomena takes place.
No signals from the remote controller are accepted.
OPE lamp is blinking.
The buzzer makes a short pipng sound.
Note:
Operation is not possible for about 30 seconds after cancellation of function selection. (Correct operation)
For description of each LED (LED1, 2, 3) provided on the indoor controller, refer to the following table.
LED1 (power for microcomputer) Indicates whether control power is supplied. Make sure that this LED is always lit.
LED2 (power for remote controller) Indicates whether power is supplied to the remote controller. This LED lights only in the case of the
indoor unit which is connected to the outdoor unit refrigerant address 0.
LED3 (communication between indoor and outdoor units) Indicates state of communication between the indoor and outdoor units. Make sure that this LED is
always blinking.
20
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
12.3. Test run method
1 Turn on the power to the unit at least 12
hours before the test run.
2 Press the
TEST RUN
button twice continuously.
(Start this operation from the status of re-
mote controller display turned off.)
A
TEST RUN
and current operation mode are dis-
played.
3 Press the
MODE
button to ac-
tivate
COOL
mode, then check whether cool
air is blown out from the unit.
4 Press the
MODE
button to ac-
tivate
HEAT
mode, then check whether warm
air is blown out from the unit.
5 Press the
FAN
button and check whether
fan speed changes.
6 Press the ON/OFF button to stop the test
run.
Note:
Point the remote controller towards the indoor unit receiver while follow-
ing steps
22
22
2 to
66
66
6.
It is not possible to run in FAN, DRY or AUTO mode.
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
TEST RUN
5
7
A
3,4
2
6
13. Troubleshooting
Remote controller communication reception error
Remote controller board error
Remote controller communication transmission error
Remote controller communication reception error
Remote controller communication transmission error
Communication between indoor and outdoor units reception error
Communication between indoor and outdoor units transmission error
Communication between indoor and outdoor units reception error
Communication between indoor and outdoor units transmission error
Indoor/outdoor connection wiring error, indoor unit overload (5 units or more)
Indoor/outdoor connection wiring error (interference, loose)
Excessive time in use
Serial communication error
Serial communication error
Reverse phase, out of phase verification
Faulty input circuit
Duplicated M-NET address setting
M-NET error in PH/W transmission
M-NET bus busy
M-NET communication error with P transmission
M-NET error no ACK
M-NET error- no response
Undefined error code
Outlet temperature error
CN23 Short-circuit Connector Unplugged
Open/short in discharge temp thermistor
Open/short in liquid temp or condenser/evaporator temp thermistor
Compressor overcurrent interruption (51C operation)
High pressure error (63H1 operation)
Low pressure error (63L operation)
Power synchronous idle circuit error
Inlet sensor error
Piping sensor error
Drain sensor error
Drain overflow protector operation
Water leak error (PDH only)
Freeze prevention operation
Surge prevention operation
Piping temperature error
Error details
13.1. How to handle problems with the test run
Error code list: details
Remote Controller
Remote Controller
Remote Controller
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
M-NET board
Outdoor unit
Outdoor unit
M-NET board
M-NET board
M-NET board
M-NET board
M-NET board
M-NET board
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Problem location
6831, 6834
6201, 6202
6832, 6833
6831, 6834
6832, 6833
6740, 6843
6841, 6842
6840, 6843
6841, 6842
6844
6845
6846
0403
0403
4103
4115
6600
6602
6603
6606
6607
6608
undefined
1102
1108
5104
5105
4101
1302
1300
4115
5101
5102
2503
2502
2500
1503
1504
1110
MELANS display
Remote controller
display
E0
E1, E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
F1
F8
A0
A2
A3
A6
A7
A8
EF
U2
U2
U3
U4
U6
UE
UL
F8
P1
P2
P4
P5
P5
P6
P6
P8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220

Mitsubishi Electric PEH-RP250MYA Guida d'installazione

Categoria
Condizionatori d'aria a sistema split
Tipo
Guida d'installazione
Questo manuale è adatto anche per