Brandt HN4636E2 Manuale del proprietario

Categoria
Cappe da cucina
Tipo
Manuale del proprietario

Questo manuale è adatto anche per

Libretto Istruzioni
Instruction Manual
Manuel d’Instructions
Bedienungsanleitung
Gebruiksaanwijzing
NL
31
DE 24
FR 17
GB
10
IT 3
AT249EX1 - AT249WE1AT249EX1 - AT249WE1
AT249EX1 - AT249WE1AT249EX1 - AT249WE1
AT249EX1 - AT249WE1
2
Cher Cliente,Cher Client,
Vous venez d ’acqérir une
hotte BRANDT hotte BRANDT
hotte BRANDT hotte BRANDT
hotte BRANDT et nous vous en remercions.
Noe équipes de recherche ont conçu pour vous une nouvelle génération d ’appareils pour cuisiner
chaque jour avec plaisir.
Avec des lignes pures et une esthétique moderne,les nouvelles hottes
Brandt Brandt
Brandt Brandt
Brandt s ’intègrent
harmonieusement dans votre cuisine et allient parfaitement confort d ’utilisation et performances d
’aspiration.
Vous trouverez également dans la gamme des produits Brandt,un vaste choix de tables de cuisson,de
fours,de lave-vaisselle et de réfrigérateurs intégrables,que vous pourrez coordonner à votre nouvelle
hotte Brandt hotte Brandt
hotte Brandt hotte Brandt
hotte Brandt .
Bien entendu,dans un souci permanent de satisfaire au mieux vos exigences vis à vis de nos
produits,notre service consommateurs est à votre disposition et à votre écoute pour répondre à
toutes vos questions ou suggestions (coordonnées à la fin de ce livret).
A la pointe de l ’innovation,Brandt contribue ainsi à l ’amélioration de la qualité de la vie quotidienne
en vous apportant des produits toujours plus performants,simples d ’utilisation, respectueux de l
’environnement,esthétiques et fiables.
La Marque BRANDT.
3IT
INDICE
CONSIGLI E SUGGERIMENTI 4
CARATTERISTICHE 5
INSTALLAZIONE 6
USO 7
MANUTENZIONE 8
4IT
CONSIGLI E SUGGERIMENTI
INSTALLAZIONE
Il produttore declina qualsiasi responsabilità per danni dovuti ad
installazione non corretta o non conforme alle regole dell’arte.
La distanza minima di sicurezza tra il Piano di cottura e la Cappa
deve essere di 650 mm.
Verificare che la tensione di rete corrisponda a quella riportata
nella targhetta posta all’interno della Cappa.
Per Apparecchi in Classe I
a
accertarsi che l’impianto elettrico do-
mestico garantisca un corretto scarico a terra.
Collegare la Cappa al Condotto di scarico con tubazione di dia-
metro pari o superiore a 120 mm. Il percorso della tubazione deve
essere il più breve possibile.
Non collegare la Cappa a condotti di scarico dei fumi prodotti da
combustione (caldaie, caminetti, ecc.).
Nel caso in cui nella stanza vengano utilizzati sia la Cappa che
Apparecchi non azionati da energia elettrica (ad esempio Appa-
recchi utilizzatori di gas), si deve provvedere ad una aerazione
sufficiente dell’ambiente. Se la cucina ne fosse sprovvista, prati-
care un’apertura che comunichi con l’esterno, per garantire il ri-
chiamo d’aria pulita.
USO
La Cappa è stata progettata esclusivamente per Uso domestico,
per abbattere gli Odori della cucina.
Non fare mai uso improprio della Cappa.
Non lasciare fiamme libere a forte intensità sotto la Cappa in fun-
zione.
Regolare sempre le fiamme in modo da evitare una evidente fuo-
riuscita laterale delle stesse rispetto al fondo delle pentole.
Controllare le friggitrici durante l’Uso: l’olio surriscaldato potrebbe
infiammarsi.
La Cappa non deve essere utilizzata da bambini o persone non
abilitate all’Uso corretto.
MANUTENZIONE
Prima di procedere a qualsiasi operazione di Manutenzione,
scollegare la Cappa togliendo la spina elettrica o spegnendo l’in-
terruttore generale.
Effettuare una scrupolosa e tempestiva Manutenzione dei Filtri
secondo gli intervalli consigliati.
Per la pulizia delle superfici della Cappa è sufficiente utilizzare
un panno umido e detersivo liquido neutro.
650mm.min.
5IT
CARATTERISTICHE
Ingombro
Tipo Cappa 60
L 598
Componenti
Rif. Q.tà Componenti di Prodotto
1 1 Corpo Cappa completo di: Comandi, Luce,
Gruppo Ventilatore, Filtri
8 1 Griglia direzionata Uscita Aria
20 1 Profilo chiusura
Rif. Q.tà Componenti di Installazione
12a 4 Viti 4,2 x 44,4
12e 2 Viti 2,9 x 9,5
Q.tà Documentazione
1 Libretto Istruzioni
0÷152
280
L
175
ø 120
12e
8
1
12a
20
6IT
INSTALLAZIONE
Foratura Piano di supporto e Montaggio Cappa
MONTAGGIO CON VITI
Il Piano di supporto della Cappa deve essere
rientrante di 220 mm dal Piano inferiore dei Pen-
sili.
Forare ø 4,5 mm il supporto utilizzando la Dima
di foratura in dotazione.
Praticare un foro ø 150 mm sul Piano di sup-
porto, utilizzando la Dima di foratura in dota-
zione.
Fissare con 4 Viti
12a12a
12a12a
12a (4,2 x 44,4) in dotazione.
PROFILO DI CHIUSURA
Lo spazio tra il bordo della Cappa e la Parete di
fondo può essere chiuso applicando il Profilo
2020
2020
20 in dotazione con le Viti già predisposte a
questo scopo.
220
20
7IT
Connessioni
USCITA ARIA VERSIONE ASPIRANTE
Per installazione in Versione Aspirante collegare la Cappa alla tubazione di uscita per mezzo di un
tubo rigido o flessibile di ø120 mm, la cui scelta è lasciata all'installatore.
Fissare il tubo con adeguate fascette stringitubo.
Il materiale occorrente non è in dotazione.
Togliere eventuali Filtri Antiodore al Carbone
attivo.
USCITA ARIA VERSIONE FILTRANTE
Praticare un foro ø 125 mm sulla Mensola
soprastante la Cappa.
Collegare l’uscita del Corpo Cappa con la parte
superiore del pensile per mezzo di un tubo rigi-
do o flessibile di ø120 mm, la cui scelta è la-
sciata all’installatore.
Fissare il tubo con adeguate fascette stringitubo.
Il materiale occorrente non è in dotazione.
Fissare la Griglia direzionata 8 sull’uscita del-
l’aria riciclata con 2 Viti 12e (2,9 x 9,5) in dota-
zione.
Assicurarsi della presenza dei Filtri Antiodore
al Carbone attivo.
CONNESSIONE ELETTRICA
Collegare la Cappa all’Alimentazione di Rete interponendo un Interruttore bipolare con apertura
dei contatti di almeno 3 mm.
Dopo aver installato la cappa è necessario per la prima volta aprire il carrello scorrevole energica-
mente fino a sentire lo scatto di fine corsa.
ø 120
12e
8
9
125125
8IT
USO
Quadro comandi
LL
LL
L Luci Accende e spegne l’Impianto di Illuminazione
MM
MM
M Motore Accende e spegne il motore Aspirazione
VV
VV
V Velocità Determina le velocità di esercizio:
1. Velocità minima, adatta ad un ricambio d’aria continuo particolarmente silen-
zioso, in presenza di pochi vapori di cottura.
2. Velocità media, adatta alla maggior parte delle condizioni d’uso, dato l’otti-
mo rapporto tra portata d’aria trattata e livello sonoro.
3. Velocità massima, adatta a fronteggiare le massime emissioni di vapore di
cottura, anche per tempi prolungati.
L
M - V
0
1
0
1
2
3
9IT
MANUTENZIONE
Filtri antigrasso
PULIZIA FILTRI ANTIGRASSO METALLICI
Necessitano di essere lavati almeno ogni 2
mesi circa di utilizzo o più frequentemen-
te, per un uso particolarmente intenso.
Togliere i Filtri uno alla volta, agendo su-
gli appositi agganci.
Lavare i Filtri evitando di piegarli, e lasciar-
li asciugare prima di rimontarli.
Rimontarli facendo attenzione a mantene-
re la Maniglia verso la parte visibile ester-
na.
Filtri antiodore (Versione Filtrante)
Sostituzione
Non sono lavabili nè rigenerabili, vanno sosti-
tuiti ogni 4 mesi circa di utilizzo o più frequen-
temente, per un uso particolarmente intenso.
Togliere i Filtri antigrasso metallici, o aprire la
Griglia portafiltri.
Rimuovere i Filtri antiodore al Carbone attivo
saturi, agendo sugli appositi agganci.
Montare i nuovi Filtri agganciandoli nella loro
sede.
Rimontare i Filtri antigrasso metallici, o
richiudere la Griglia portafiltri.
Illuminazione
SOSTITUZIONE LAMPADE
Lampade a incandescenza da 40 WLampade a incandescenza da 40 W
Lampade a incandescenza da 40 WLampade a incandescenza da 40 W
Lampade a incandescenza da 40 W
Togliere i Filtri antigrasso metallici, o aprire la
Griglia portafiltri.
Svitare le lampade e sostituirle con nuove di
uguali caratteristiche.
Rimontare i Filtri antigrasso metallici, o
richiudere la Griglia portafiltri.
10GB
RECOMMENDATIONS AND SUGGESTIONS 11
CHARACTERISTICS 12
INSTALLATION 13
USE 15
MAINTENANCE 16
CONTENTS
11GB
RECOMMENDATIONS AND SUGGESTIONS
INSTALLATION
The manufacturer will not be held liable for any damages resulting
from incorrect or improper installation.
The minimum safety distance between the cooker top and the
extractor hood is 650 mm.
Check that the mains voltage corresponds to that indicated on the
rating plate fixed to the inside of the hood.
For Class I appliances, check that the domestic power supply
guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of
minimum diameter 120 mm. The route of the flue must be as short
as possible.
Do not connect the extractor hood to exhaust ducts carrying
combustion fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances
(e.g. gas burning appliances), a sufficient degree of aeration must
be guaranteed in the room in order to prevent the backflow of
exhaust gas. The kitchen must have an opening communicating
directly with the open air in order to guarantee the entry of clean
air.
USE
The extractor hood has been designed exclusively for domestic
use to eliminate kitchen smells.
Never use the hood for purposes other than for which it has ben
designed.
Never leave high naked flames under the hood when it is in
operation.
Adjust the flame intensity to direct it onto the bottom of the pan
only, making sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use:
overheated oil can burst into flames.
The hood should not be used by children or persons not instructed
in its correct use.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before
carrying out any maintenance work.
Clean and/or replace the Filters after the specified time period.
Clean the hood using a damp cloth and a neutral liquid detergent.
650mm.min.
12GB
CHARACTERISTICS
Dimensions
Components
Ref. Q.ty Product Components
1 1 Hood Body, complete with: Controls, Light,
Blower, Filters
8 1 Directional Air Outlet grille
20 1 Closing element
Ref. Q.ty Installation Components
12a 4 Screws 4,2 x 44,4
12e 2 Screws 2,9 x 9,5
Q.ty Documentation
1 Instruction Manual
Hood Type 60
L 598
0÷152
280
L
175
ø 120
12e
8
1
12a
20
13GB
220
INSTALLATION
Drilling the Support surface and Fitting the Hood
SCREW FITTING
The hood support surface must be 220 mm
above the bottom surface of the wall units.
Drill the support with a ø 4,5 mm drill bit, using
the drilling template provided.
Cut a hole ø 150 mm in size on the support
surface, using the drilling template provided.
Fix using the 4 screws
12a12a
12a12a
12a (4,2 x 44,4) provided.
CLOSING ELEMENT
The space between the edge of the hood and the
rear wall can be closed by applying the element
20 20
20 20
20 provided, using the screws supplied for this
purpose.
20
14GB
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 120 mm, the choice of which is left to the installer.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
Cut a hole ø 125 mm in the wall unit over the hood.
Connect the hood body outlet to the top part of the
wall unit using a rigid or flexible pipe ø120 mm, to
be selected by the installer.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Fix the directional grille 8 on the recirculation air
outlet using the 2 screws 12e (2,9 x 9,5) provided.
Ensure that the activated charcoal filters have been
inserted.
ELECTRICAL CONNECTION
Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
When opening the sliding carriage for the first time after installing the hood, pull it out briskly
until it clicks.
ø 120
12e
8
9
125125
15GB
USE
Control panel
LL
LL
L Light Switches the lighting system on and off.
MM
MM
M Motor Switches the extractor motor on and off.
V1V1
V1V1
V1 Speed Sets the operating speed of the extractor:
1. Low speed, used for a continuous and silent air change in the presence of light
cooking vapour.
2. Medium speed, suitable for most operating conditions given the optimum
treated air flow/noise level ratio.
3. Maximum speed, used for eliminating the highest cooking vapour emission,
including long periods
L
M - V
0
1
0
1
2
3
16GB
MAINTENANCE
Grease filters
CLEANING METAL GREASE FILTERS
The filters must be cleaned every 2 months
of operation, or more frequently for
particularly heavy usage.
Remove the filters, one at a time, after
disconnecting the relative fastening
elements.
Wash the filters, taking care not to bend
them. Allow them to dry before refitting.
When refitting the filters, make sure that
the handle is visible on the outside.
Odour filters (Recirculation version)
REPLACING ACTIVATED CHARCOAL FILTERS
These filters are not washable and cannot be
regenerated, and must be replaced
approximately every four months of operation,
or more frequently with heavy usage.
Remove the metal grease filters, or open the
filter retaining grill.
Remove the saturated activated carbon filters
by releasing the fixing hooks.
Fit the new filters by hooking them into their
seating.
Replace the metal grease filters, or close the
filter retaining grill.
Lighting
LIGHT REPLACEMENT
40 W incandescent light40 W incandescent light
40 W incandescent light40 W incandescent light
40 W incandescent light
Remove the metal grease filters, or open the
filter retaining grill.
Unscrew the bulbs and replace them with new
ones having the same characteristics.
Replace the metal grease filters, or close the
filter retaining grill.
17FR
SOMMAIRE
CONSEILS ET SUGGESTIONS 18
CARACTERISTIQUES 19
INSTALLATION 20
UTILISATION 22
ENTRETIEN 23
18FR
CONSEILS ET SUGGESTIONS
INSTALLATION
Le fabricant décline toute responsabilité en cas de dommage dû à
une installation non correcte ou non conforme aux règles de l’art.
La distance minimale de sécurité entre le plan de cuisson et la
hotte doit être de 650 mm au moins.
Vérifier que la tension du secteur correspond à la valeur qui figure
sur la plaquette apposée à l’intérieur de la hotte.
Pour les Appareils appartenant à la Ière Classe, veiller à ce que la
mise à la terre de l’installation électrique domestique ait été
effectuée conformément aux normes en vigueur.
Connecter la hotte à la sortie d’air aspiré à l’aide d’une tuyauterie
d’un diamètre égal ou supérieur à 120 mm. Le parcours de la
tuyauterie doit être le plus court possible.
Eviter de connecter la hotte à des conduites d’évacuation de fumées
issues d’une combustion tel que (Chaudière, cheminée, etc…).
Si vous utilisez des appareils qui ne fonctionnent pas à l’électricité
dans la pièce ou est installée la hotte (par exemple: des appareils
fonctionnant au gaz), vous devez prévoir une aération suffisante
du milieu. Si la cuisine en est dépourvue, pratiquez une ouverture
qui communique avec l’extérieur pour garantir l’infiltration de
l’air pur.
UTILISATION
La hotte a été conçue exclusivement pour l’usage domestique, dans
le but d’éliminer les odeurs de la cuisine.
Ne jamais utiliser abusivement la hotte.
Ne pas laisser les flammes libres à forte intensité quand la hotte
est en service.
Toujours régler les flammes de manière à éviter toute sortie latérale
de ces dernières par rapport au fond des marmites.
Contrôler les friteuses lors de l’utilisation car l’huile surchauffée
pourrait s’enflammer.
La hotte ne doit pas être utilisée par des enfants ou des personnes
ne pouvant pas assurer une utilisation correcte.
ENTRETIEN
Avant de procéder à toute opération d’entretien, retirer la hotte en
retirant la fiche ou en actionnant l’interrupteur général.
Effectuer un entretien scrupuleux et en temps dû des Filtres, à la
cadence conseillée.
Pour le nettoyage des surfaces de la hotte, il suffit d’utiliser un
chiffon humide et détersif liquide neutre.
650mm.min.
19FR
CARACTERISTIQUES
Encombrement
Hotte Type 60
L 598
Composants
Réf. Q.té Composants de Produit
1 1 Corps Hotte équipé de:Comandes,
Lumière,Groupe Ventilateur,Filtres
8 1 Grille orientée Sortie de l ’Air
20 1 Profil fermeture
Réf. Q.té Composants pour l ’installation
12a 4 Vis 4,2 x 44,4
12e 2 Vis 2,9 x 9,5
Q.té Documentation
1 Manuel d’instructions
0÷152
280
L
175
ø 120
12e
8
1
12a
20
20FR
INSTALLATION
Perçage du Plan de support et Montage de la Hotte
MONTAGE AU MOYEN DE VIS
Le Plan de support de la Hotte doit être monté
plus en haut de 220 mm. par rapport au Plan
inférieur des Armoires murales.
Percer un trou de ø 4,5 mm. sur le support, en
utilisant le Gabarit de perçage fourni avec
l’appareil.
Percer un trou de ø 150 mm. sur le Plan de
support, en utilisant le Gabarit de perçage fourni
avec l’appareil.
Fixer à l’aide des 4 Vis
12a12a
12a12a
12a (4,2 x 44,4) fournies
avec l’appareil.
PROFIL DE FERMETURE
Il est possible de boucher l’espace entre le rebord
de la Hotte et la Paroi du fond, en appliquant le
Profil
2020
2020
20 fourni avec l’appareil, à l’aide des Vis
déjà prévus à cet effet.
220
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Brandt HN4636E2 Manuale del proprietario

Categoria
Cappe da cucina
Tipo
Manuale del proprietario
Questo manuale è adatto anche per