Samsung AW14PHBA Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente

Questo manuale è adatto anche per

DB98-20384A(3)E S F P I
OWNER'S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
MANUAL DE INSTRUÇÕES
ISTRUZIONI PER L'USO
ENGLISH
ESPAÑOL
FRANÇAIS
PORTUGUÊS
ITALIANO
Window-type Room Air Conditioner (Cool)
Acondicionador de airea doméstico sistema de tipo ventana (Reirigeración)
Climatiseur de type Fenêtre (Refroidissement)
O ar Condicionado de Window-Type (Refrigeracçã)
Condizionatore d'aria per ambienti da finestra (Raffreddamento)
AW12PHHAA
AW12PHHBA
AW12PHHDA
AW12PH(K)HEA
AWT12PHHBA
AWT12PHHEA
AW09PHHBA
AW09PHHDA
AW09PH(K)HEA
AW24PHHBA/BB/BC/BD
AW24PH(K)HEA/EB
AW14PHHBA
AW18PH(K)HEA
AW18PHHBA AWT18PH(K)HEA/EB
AW07PHHBA
AW07PH(K)HEA
AW09PHHAA
AWT24PH(K)HEA/EB/EC
E-2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their
own
discretion. Instead, they are requested to directly contact a designated
service
center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch
off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the
breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7
meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. Can cause injury or death. Disconnect all
remote
electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar
qualified
person in order to avoid a hazard.
AQ07S2GE IB_E_15110 04/2/2 15:35 Page 2
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Never store or ship the air conditioner upside down or sideways to avoid damage
to
the compressor.
The appliance is not intended for use by young children or infirm persons without
supervision:
Young children should be supervised to ensure that they do not play
with
the appliance.
Max current is measured according to IEC standard for safety and current is
measured
according to ISO standard for energy efficiency.
OTHERS
Before throwing out the device, it is necessary to pull back the battery cells and
get
rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectl
y, refrigerant may blow out and come into contact with your skin,causing
injur
y. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally
responsible manner.
D
ISPOSING OF THE UNIT
Register your product at www.samsung.com/global/register
E-3
Contents
PREPARING YOUR AIR CONDITIONER
Safety Precautions
Air Conditioning Unit-Main
Parts, Buttons and Display
Remote Control-Button
s
Getting Started
Inse
rting the Remote Control Batteries
Cooling Your Room
Airing Your Room
Adjusting the Air Fl
ow Direction Horizontally
Adjusting thr Air Fl
ow Direction Vertically
OPERATING YOUR AIR CONDITIONER
Setting the On Timer
Setting the O
ff Timer
Setting the Sleep
Timer
Selecting Energy s
aving mode
PROGRAMMING YOUR AIR CONDITIONER
Temperature and Humidity Ranges
Cleaning Your Air Conditioner
Solving Common Pro
blems
Technical Specifications
RECOMMENDATIONS FOR USE
INSTALLSTION
2
4
5
6
7
8
9
11
11
12
13
14
15
15
16
17
18
19
HSILGNE
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
"The high in
rush current of the starting compressor motor can have adverse effects to
the ope
ration of other equipment under unfavorable mains conditions. This equipment
does not comply with the rel
evant technical standards for the limitation of voltage
fluctuations and flick
er."
Be
fore connection this equipment to the power supply system, please report to your
suply autho
rity and obtain the consent.
Do not connect other elect
ric appliances to the same supply lines.
The maxi
mum permissible system impedance at the power junction box is 0.24 ohms.
Usuall
y, the maximum permissible mains impedance will not be exceeded when the
branch to the power outlet is fed from a junction box with a rated current of 32A.
AW18
**
Removing Excess Humidity ............................................................................ 10
E-4
Air Conditioning Unit - Main Parts, Buttons and Display
The design and shape are subject to
change according to the model.
Air inlet (Inside)
Ventilation lever
Air inlet (Outside)
Outer air flow blades
(up/down orientation)
Inner air flow blades
(right/left orientation)
Temperature/
Timer settings
Temperature adjustment
buttons
Energy Saver indicator
Remote Control sensor
Air flow blade
swing button
Fan speed adjustment
button
On/Off button
Operating mode indicators
(COOL, DRY,FAN)
Sleep timer setting button
Timer setting button
Timer indicator
Sleep indicator
Energy Saver button
Operating mode selection
button (COOL,DRY, FAN)
Power plug
The type of the power plug
may differ according to the
type of local power supply.
The power plug may be not supplied
depending on the model.
The air filter is
located in side
Air Outlet
E-6
Gray background.
Example:
White background.
Example:
Getting Started
You have just purchased a window-type room air conditioner and it has been installed by your
installation specialist.
Y
our Owenr's Instructions contain valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit's functions.
This Owner's Instructions is just for using your air conditioner correctly.
Thus, the illustrations shown in this manual may not exactly match your air conditioners.
The booklet is organized as follows.
The following figures are shown on pages 4 and 5:
Air conditioning unit (main parts, buttons and display)
Remote control (buttons)
They will help you find the buttons and understand the symbols displayed.
In the manual, you will find a series of step-by-step procedures for each function available.
The illustrations in the step-by-step procedures use four dif
ferent symbols:
Moreover,applicable, wherever the illustrations show the positions of the buttons on both the
remote control and the unit itself.
For the...
The illustrations have a...
Remote control
Unit itself
E-7
Inserting the Remote Control Batteries
You must insert or replace the remote control batteries when:
You purchase the air conditioner
The remote control does not work correctly
Use two AAA, LR03 1.5V batteries. Do not use old
batteries or different kinds of batteries together.
Batteries may be completely discharged after 12 months,
even if they have not actually been used.
1 Push the battery cover on the rear of the remote control with your thumb in
the direction of the arrow and remove it.
2 Insert the two batteries,taking care to respect the polarities:
+ on the battery with + on the remote control
- on the battery with - on the remote control
3 Close the cover by sliding it back unitl it clicks into place.
You can control all the functions your air conditioning unit
directly from your seat, using the remote control.
Result:
ENGLISH
3 To adjust the temperature, press the or button on the remote
control one or more times until the required temperature is displayed.
To adjust the temperature, press the or button on the unit one
or more times until the required temperature is displayed.
Possible temperatures are between 18 C and 30 C inclusive.
Each time you press the temperaure bottons:
The temperature is adjusted by 1 C and
displayed on the control panel
The unit beeps
The air conditioner starts cooling if the room temperature is
higher than the selected temperature.
E-8
Cooling Your Room
Remote Control
Control Panel
Dry
You must select the Cool mode if you wish to lower the temperature in your
room. You can also set the fan speed.
1 If necessary, press the (On/Off )button.
The air conditioner starts up in the Cool mode.
The unit beeps twice.
Result:
Result:
The air conditioner is fitted with a protection mechanism to prevent
the unit from being damaged when it is started immediately after
being:
Plugged in
Stopped
It will start up automatically after about three minutes.
2 If the COOL indicator is not lit up on the unit:
Press the button on the remote control
or
Press the button on the unit one or more times until the COOL
indicator lights up
The unit beeps each time you press the / button.
The air conditioner starts up in Cool mode.
You can change modes at any time.
Result:
4 To set the fan speed to... Then...
Press the , or button on the remote control as desired.
or
Press the button on the unit one or more times until the the
desired fan speed(F1, F2, or F3) is displayed.
:
:
:
Low Speed
Med Speed
High Speed
5 To control the direction of the air flow, refer to page 10.
E-9
Airing Your Room
Remote Control
Control Panel
If the atmosphere in your room is stale, you can air it using the Fan
feature and if necessary, evacuate the stale air outside.
1 If you wish to evacuate stale air outside, push the ventilation lever on the
front
of the unit to the right and the open position ( ).
The air inside the room circulates and stale air is evacuated
outside.
Result:
Result:
Otherwise, push the ventilation lever to the left and the closed
position ( ).
The air simply circulates inside the room.
2 If necessary, press the (On/Off) button.
The air conditioner starts up in the Cool mode.
The unit beeps twice.
Result:
3 If the FAN indicator is not lit up on the unit:
Press the button on the remote control
or
Press the button on the unit one or more times until the
FAN indicator lights up.
The unit beeps each time you press the / button.
The air conditioner starts up in Cool mode.
4 To set the fan speed to... Then...
Press the , or button on the remote control as desired.
or
Press the button on the unit one or more times until the the
desired fan speed(F1, F2, or F3) is displayed.
:
:
:
Low Speed
Med Speed
High Speed
5 To control the direction of the air flow, refer to page 10.
You can change modes at any time.
When the air conditioner is in the Fan mode, the temperature
is not displayed; in this case, you do not need to set the
temperature.
Result:
ENGLISH
E-
10
Removing Excess Humidity
If the atmosphere in your room is very humid or damp, you can remove
exce
ss humidity without lowering the room temperature too much.
1 If necessary, press the (On/Off) button.
Result
: The air conditioner starts up in the Cool mode.
The
unit beeps.
The
air conditioner is fitted with a protection mechanism to pre-
vent
the unit from being damaged when it is started immediately
after
being:
Plugged
in
Stopped
It
will start up normally after three minutes.
2 If the
temperature
is not displayed at the top of the control panel, press
the
button on the control panel one or more times until it
appears.
Result
:
The unit beeps each time you press the button.
The
air conditioner runs in Dry mode.
You can change modes at any time.
3 To adjust the temperature, press the
or
buttons one or
more
times until the required temperature is displayed.
Possible
temperatures are between
18
°C
and 30
°
C
inclusive.
Result
: Each time you press the
or
buttons:
- The temperature is adjusted by 1
°
C
- The unit beeps
The
air conditioner starts removing the excess humidity;
the
quantity of air is adjusted automatically.
4 To control the direction of the air flow, refer to page 11.
Remote Control Control Panel
Dry
Be sure to clean the air filter periodically to maintain the air conditioner in
the best condition for a long period of time.
When cleaning the air conditioner, turn it off and pull out
the power plug.
E-
16
CleaningYour Air Conditioner
1 Hold the front grille handle, slightly pull it to the left side and open the front grille.
2 Pull the air filter to the right side.
3 Remove all dust on the air filter with a vacuum cleaner or brush.
4 When you have finished, insert the air filter back into its original position.
5 Wipe the surface of the unit with a neutral detergent and then wipe it again
with dry cloth.
(Be sure not to use benzene, solvent or other chemical products.)
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
The removal of the front grille makes it easier to clean the air
conditioner. Open the grille as much as possible.
If you... Then...
Will not be using the
air conditioner for a
long period of time
Have not used the air
conditioner for a long
period of time
Set the fan going for a few hours to
dry the inside of the air conditioner
thoroughly.
Switch the air conditioner off and
unplug it from the wall socket.
Clean the filter and outer surfaces.
Set the fan going for a few hours to
dry the inside of the air conditioner
thoroughly.
Removal and Reassembly of the Front Grille
IMPORTANT
For user's safety, a safety clip has been installed in the front grille.
1 Grasp the lower part of the front
grille and the front grille handle,
then open the grille. (The open
angle of front grille has not to be
exceeded 25 degree)
2 Lift the front grille slightly and
remove it from the front panel.
3 Reassembling of front grille
should be done in reverse
order of disassembly.
The air conditioner has two or three grille
grooves depending on the model.
E-
19
Installation (for 60Hz)
1 Electrical Requirements
For personal safety:
This appliance
must be properly grounded.
Do not, under a
ny circumstances, cut or remove the third grounding prong
from the p
ower cord.
We recommend that you do not use an extension cord or an adapter plug with
this applianc
e.
Do not change the plug on the p
ower cord of this appliance.
Follow national electrical codes or local codes and ordinances.
If the elect
ric supply provided does not meet the above specifications, call a
licensed elect
rician.
Alumi
num house wiring may pose special problemsconsult a qualified
elect
rician.
This unit requires a sepa
rate circult, serving only this appliance.
115V
15 AMP Circui
t
"pa
rallel" type
230V/208
V
20 AMP circui
t
"pe
rpendicular" type
230V/208
V
15AMP circui
t
"tandem" typ
e
230V/208
V
30 AMP circui
t
"tandem" typ
e
HSILGNE
E-
20
500mm 500mm
75mm
min.
300mm
500mm
150mm min.
"A"
Approx.3
Awning
750mm
100mm or more
Outdoor side
Indoor side
45
45
If the wall is greater than 150mm thick,
cut the
wall back on a 45 angle if possible.
Installation
Before installation, be sure to check the installation area or the air
conditione
r, and drain hose.
Checkpoints prior to installation
Installation Conditions
1 Che
ck the cabinet and front grille of the unit for any harmful defects
such as sc
ratches.
1 As the unit is he
avy, the wall or window of the installation area should
have sufficient strength and durability for operation of the air conditioner,
and
for prevention of any vibration or noise.
If it is
weak, reinforcement work should be performed separately.
3 When installing the air conditioner, be sure to obtain sufficient space on
the rear side of the unit
for smooth flow of air.
When ope
rating the air conditioner in closed areas such as inner building
with cooling ope
ration, and result in trouble with the unit.
See the illust
ration below.
2 It is advisable to install the air conditioner in the north or west side to
pr
event the effect of direct sunlight.
When installing it in the south or east side due to un
avoidable
circumstance
s, it is advisable to install the sunshade to prevent the
direct sunlight
.
In this cas
e, take care not to cause any hindrance to the flow of outside air.
2 Be sure to che
ck the power supply.
- Re
fer to the specifications on the label attached to the unit.
Fence, wall
or othe
r
obstacl
e
The appliance must be fixed well by screw or similar
method
.
"A"
145
170
260
MODEL
AW07/AW09
AW12/AWT12
AW14/AW18/AW24
AWT18/AWT24
260
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Samsung AW14PHBA Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue