Dolby Laboratories 585 Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

Model 585
Time Scaling Processor
Issue 2 Part Number 91796
Model 585 Time Scaling Processor
ii
Dolby Laboratories, Inc.
Corporate Headquarters
Dolby Laboratories, Inc.
100 Potrero Avenue
San Francisco, CA 94103-4813
Telephone 415-558-0200
Fax 415-863-1373
www.dolby.com
European Headquarters
Dolby Laboratories, Inc.
Wootton Bassett
Wiltshire, SN4 8QJ, England
Telephone (44) 1793-842100
Fax (44) 1793-842101
DISCLAIMER OF WARRANTIES:
EQUIPMENT MANUFACTURED BY DOLBY LABORATORIES IS WARRANTED AGAINST DEFECTS IN
MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE.
THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES AND NO WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OF NONINFRINGEMENT OF
THIRD-PARTY RIGHTS (INCLUDING, BUT NOT LIMITED TO, COPYRIGHT AND PATENT RIGHTS).
LIMITATION OF LIABILITY:
IT IS UNDERSTOOD AND AGREED THAT DOLBY LABORATORIES’ LIABILITY, WHETHER IN
CONTRACT, IN TORT, UNDER ANY WARRANTY, IN NEGLIGENCE, OR OTHERWISE SHALL NOT
EXCEED THE COST OF REPAIR OR REPLACEMENT OF THE DEFECTIVE COMPONENTS OR ACCUSED
INFRINGING DEVICES, AND UNDER NO CIRCUMSTANCES SHALL DOLBY LABORATORIES BE
LIABLE FOR INCIDENTAL, SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES,
(INCLUDING, BUT NOT LIMITED TO, DAMAGE TO SOFTWARE OR RECORDED AUDIO OR VISUAL
MATERIAL), COST OF DEFENSE, OR LOSS OF USE, REVENUE, OR PROFIT, EVEN IF DOLBY
LABORATORIES OR ITS AGENTS HAVE BEEN ADVISED, ORALLY OR IN WRITING, OF THE
POSSIBILITY OF SUCH DAMAGES.
Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. Part Number 91796
All other trademarks remain the property of their respective owners. Issue 2
2003 Dolby Laboratories, Inc. All rights reserved. S03/14154/14618
Model 585 Time Scaling Processor
iii
Table of Contents
List of Figures................................................................................................................v
List of Tables .................................................................................................................v
Regulatory Notices....................................................................................................... vi
Fusing Information ...................................................................................viii
Chapter 1 Introduction...........................................................................................1-1
Chapter 2 Getting Started......................................................................................2-1
2.1 Unpacking and Inspection............................................................2-1
2.2 Installing.......................................................................................2-1
2.3 Rear Panel ...................................................................................2-2
2.3.1 Digital Audio Connections ................................................2-2
2.3.2 Serial Connection Ports....................................................2-3
2.3.3 Remote Connection Ports ................................................2-4
2.4 Front Panel...................................................................................2-4
2.4.1 Reading the Display .........................................................2-5
2.4.2 Buttons.............................................................................2-5
2.4.3 Knob.................................................................................2-6
2.5 Status Menu.................................................................................2-7
2.6 Setup Menu..................................................................................2-8
2.6.1 Program Configuration .....................................................2-8
2.6.2 Operating Mode................................................................2-9
2.6.3 System Settings .............................................................2-11
Chapter 3 Time Scaling..........................................................................................3-1
3.1 Transport Menu............................................................................3-1
3.1.1 Play ..................................................................................3-2
3.1.2 Record..............................................................................3-5
3.1.3 Program Selection............................................................3-5
3.2 Time Scaling of Longer Programs................................................3-6
Chapter 4 Pitch Shifting.........................................................................................4-1
4.1 Adjusting the Pitch Shifting Value.................................................4-1
4.2 Using Pitch Shifting to Perform Online Time Scaling....................4-2
Chapter 5 Applications...........................................................................................5-1
5.1 Stand-Alone Processing...............................................................5-1
5.2 Processing with Synchronized Video............................................5-2
Model 585 Time Scaling Processor
iv
Chapter 6 Principles of Operation.........................................................................6-1
6.1 Multichannel Delivery ...................................................................6-1
6.2 Development of Time Scaling.......................................................6-2
6.2.1 Time-Domain Solutions....................................................6-2
6.2.2 Frequency-Domain Solutions...........................................6-2
6.2.3 Modeling-Based Solutions................................................6-3
6.2.4 Choosing a Solution .........................................................6-3
6.3 Intelligent Analysis........................................................................6-3
Chapter 7 Reference Data......................................................................................7-1
7.1 Channel Mapping .........................................................................7-1
7.2 Specifications...............................................................................7-2
Model 585 Time Scaling Processor
v
List of Figures
Figure 1 Checking the Main Fuse..................................................................................viii
Figure 2-1 Connections: Signal In and Out...................................................................2-2
Figure 2-2 Connections: Remote RS-232, GP I/O, Metadata In and Out.....................2-3
Figure 2-3 Model 585 Front Panel................................................................................2-4
Figure 2-4 Front-Panel Buttons ....................................................................................2-5
Figure 5-1 Stand-Alone Time Scaling...........................................................................5-2
Figure 5-2 Single-Pass Pitch Shifting ...........................................................................5-3
List of Tables
Table 2-1 Front-Panel Button Definitions......................................................................2-6
Table 2-2 Status Menu Screens...................................................................................2-7
Table 3-1 Play Menu Button Mapping ..........................................................................3-2
Table 7-1 Channel Mapping according to Program Configuration................................7-1
Model 585 Time Scaling Processor
vi
Regulatory Notices
USA
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with this instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his or her own expense.
WARNING: Troubleshooting must be performed by a trained technician. Do
not attempt to service this equipment unless you are qualified to do so.
Check that the correct fuses have been installed. To reduce the risk of fire,
replace only with fuses of the same type and rating.
Exposed portions of the power supply assembly are electrically “hot.” To reduce risk of electric
shock, the power cord
must be disconnected when the power supply assembly is removed.
The ground terminal of the power plug is connected directly to
the chassis of the unit. For continued protection against
electric shock, a correctly wired and grounded (earthed) three-
pin power outlet must be used. Do not use a ground-lifting
adapter and never cut the ground pin on the three-prong plug.
WARNING: Before applying power, check the main fuse using the procedure on
page viii.
Canada
This Class A digital apparatus complies with Canadian ICES-003.
EU
This equipment complies with the EMC requirements of EN55103-1 and EN55103-2 when
operated in an E2 environment in accordance with this manual.
UK
Use power cord Dolby part number 92031 supplied with unit (pre-fitted with 13A plug to
BS1363) to connect Model 585 to the mains supply. This equipment must be earthed.
Model 585 Time Scaling Processor
vii
IMPORTANT SAFETY NOTICE
This unit complies with the safety standard EN60065. The unit shall not be exposed to dripping or splashing and no objects filled with liquids,
such as coffee cups, shall be placed on the equipment. To ensure safe operation and to guard against potential shock hazard or risk of fire, the
following must be observed:
o Ensure that your mains supply is in the correct range for the input power requirement of the unit.
o Ensure fuses fitted are the correct rating and type as marked on the unit.
o The unit must be earthed by connecting to a correctly wired and earthed power outlet.
o The power cord supplied with this unit must be wired as follows:
Live—Brown Neutral—Blue Earth—Green/Yellow
IMPORTANT – NOTE DE SECURITE
Ce materiel est conforme à la norme EN60065. Ne pas exposer cet appareil aux éclaboussures ou aux gouttes de liquide. Ne pas poser d'objets
remplis de liquide, tels que des tasses de café, sur l'appareil. Pour vous assurer d'un fonctionnement sans danger et de prévenir
tout choc électrique ou tout risque d'incendie, veillez à observer les recommandations suivantes.
o Le selecteur de tension doit être placé sur la valeur correspondante à votre alimentation réseau.
o Les fusibles doivent correspondre à la valeur indiquée sur le materiel.
o Le materiel doit être correctement relié à la terre.
o Le cordon secteur livré avec le materiel doit être cablé de la manière suivante:
Phase—Brun Neutre—Bleu Terre—Vert/Jaune
WICHTIGER SICHERHEITSHINWEIS
Dieses Gerät entspricht der Sicherheitsnorm EN60065. Das Gerät darf nicht mit Flüssigkeiten (Spritzwasser usw.) in Berührung kommen; stellen
Sie keine Gefäße, z.B. Kaffeetassen, auf das Gerät. Für das sichere Funktionieren des Gerätes und zur Unfallverhütung (elektrischer Schlag,
Feuer) sind die folgenden Regeln unbedingt einzuhalten:
o Der Spannungswähler muß auf Ihre Netzspannung eingestellt sein.
o Die Sicherungen müssen in Typ und Stromwert mit den Angaben auf dem Gerät übereinstimmen.
o Die Erdung des Gerätes muß über eine geerdete Steckdose gewährleistet sein.
o Das mitgelieferte Netzkabel muß wie folgt verdrahtet werden:
Phase—braun Nulleiter—blau Erde—grün/gelb
NORME DI SICUREZZA – IMPORTANTE
Questa apparecchiatura è stata costruita in accordo alle norme di sicurezza EN60065. Il prodotto non deve essere sottoposto a schizzi, spruzzi e
gocciolamenti, e nessun tipo di oggetto riempito con liquidi, come ad esempio tazze di caffè, deve essere appoggiato sul dispositivo. Per una
perfetta sicurezza ed al fine di evitare eventuali rischi di scossa êlettrica o d'incendio vanno osservate le seguenti misure di sicurezza:
o Assicurarsi che il selettore di cambio tensione sia posizionato sul valore corretto.
o Assicurarsi che la portata ed il tipo di fusibili siano quelli prescritti dalla casa costruttrice.
o L'apparecchiatura deve avere un collegamento di messa a terra ben eseguito; anche la connessione rete deve
avere un collegamento a terra.
o Il cavo di alimentazione a corredo dell'apparecchiatura deve essere collegato come segue:
Filo tensione—Marrone Neutro—Blu Massa—Verde/Giallo
AVISO IMPORTANTE DE SEGURIDAD
Esta unidad cumple con la norma de seguridad EN60065. La unidad no debe ser expuesta a goteos o salpicaduras y no deben colocarse sobre el
equipo recipientes con liquidos, como tazas de cafe. Para asegurarse un funcionamiento seguro y prevenir cualquier posible peligro de descarga o
riesgo de incendio, se han de observar las siguientes precauciones:
o Asegúrese que el selector de tensión esté ajustado a la tensión correcta para su alimentación.
o Asegúrese que los fusibles colocados son del tipo y valor correctos, tal como se marca en la unidad.
o La unidad debe ser puesta a tierra, conectándola a un conector de red correctamente cableado y puesto a tierra.
o El cable de red suministrado con esta unidad, debe ser cableado como sigue:
Vivo—Marrón Neutro—Azul Tierra—Verde/Amarillo
VIKTIGA SÄKERHETSÅTGÄRDER
Denna enhet uppfyller säkerhetsstandard EN60065. Enheten får ej utsättas för yttre åverkan samt föremål innehållande vätska, såsom
kaffemuggar, får ej placeras på utrustningen." För att garantera säkerheten och gardera mot eventuell elchock eller brandrisk, måste följande
observeras:
o Kontrollera att spänningsväljaren är inställd på korrekt nätspänning.
o Konrollera att säkringarna är av rätt typ och för rätt strömstyrka så som anvisningarna på enheten föreskriver.
o Enheten måste vara jordad genom anslutning till ett korrekt kopplat och jordat el-uttag.
o El-sladden som medföljer denna enhet måste kopplas enligt foljande:
Fas—Brun Neutral—Blå Jord—Grön/Gul
BELANGRIJK VEILIGHEIDS-VOORSCHRIFT
Deze unit voldoet aan de EN60065 veiligheids-standaards. Dit apparaat mag niet worden blootgesteld aan vocht. Vanwege het risico dat er
druppels in het apparaat vallen, dient u er geen vloeistoffen in bekers op te plaatsen. Voor een veilig gebruik en om het gevaar van electrische
schokken en het risico van brand te vermijden, dienen de volgende regels in acht te worden genomen:
o Controleer of de spanningscaroussel op het juiste Voltage staat.
o Gebruik alleen zekeringen van de aangegeven typen en waarden.
o Aansluiting van de unit alleen aan een geaarde wandcontactdoos.
o De netkabel die met de unit wordt geleverd, moet als volgt worden aangesloten:
Fase—Bruin Nul—Blauw Aarde—Groen/Geel
F
E
NL
S
I
D
GB
Model 585 Time Scaling Processor
viii
Fusing Information
WARNING: To reduce the risk of fire, replace fuses only with the same type
and rating.
The unit uses a universal switching power supply that handles the full range of nominal
mains voltages between 90 and 264 VAC and any frequency between 50 and 60 Hz.
Check Main Fuse
The Main fuse rating is:
T 1A L (1 Amp, 250 V, 20 mm, time-lag, low-breaking capacity) for all operating
voltages.
WARNING: The power to the unit must be off when the following steps are
performed. Ensure that the main power cable to the unit is not connected to a
power source.
1. Open the fuse compartment door in the AC power input housing with a small flat-
blade screwdriver (Figure 1). Carefully pull out the fuse carrier.
2.
Check that the fuse has the correct rating. The fuse carrier must be inserted into
the compartment with the orientation shown in Figure 1.
Do not force the carrier
into the compartment or both could be damaged.
3.
Snap the fuse compartment door closed.
Fuse carrier
Installed fuse
Open the door
Figure 1 Checking the Main Fuse
Internal Fuse
The switching power supply contains a separate fuse. Most fault conditions should be
protected by the main fuse.
If you find it necessary to replace the internal fuse, be certain to replace it with a fuse
of the same type and rating as printed on the switching power supply board.
Model 585 Time Scaling Processor
1-1
Chapter 1
Introduction
The Model 585 Time Scaling Processor delivers true time scaling and pitch shifting
for the studio professional.
A change in the playback speed of analog tape—or in the sample playback rate for
digital formats—has always brought about a change in the audio pitch as well as the
duration of the audio program being played. However, this fixed link between
playback speed and pitch has often meant a compromise in audio quality. Therefore,
the ability to precisely determine and alter pitch and program duration
independently
has been a necessity since it first became possible to alter the speed of a recording.
Today, many standard operations result in a change in audio pitch; for example, when
converting a film for broadcast at 25 fps, or adjusting a program’s length to match the
available broadcast time slot.
There have been attempts over the years to provide pitch shifting and time scaling.
Early products showed glaring weaknesses, and more recent attempts have tended to
be useful only on a limited range of material. Model 585 delivers dependable
processing of any signal, across the whole spectrum of audio: music, speech, special
effects, and any combination of these elements.
Multichannel Delivery
Model 585 is the first product to deliver truly phase-synchronous time scaling and
pitch shifting for multiple (up to eight) channels of audio—something multiple stereo
processors cannot achieve. It is important to preserve the phase relationship of
multichannel audio programs for all listeners; it is especially important for those with
stereo or mono reproduction equipment, who hear a summing of the multichannel
elements. Model 585 is compatible with all Dolby
®
E products.
Real-Time Time Scaling and Pitch Shifting
Model 585 delivers two separate functions: time scaling and pitch shifting. Each
function can be applied in real time.
Time scaling alters the duration of an audio signal but leaves the perceived pitch
unchanged from the original signal. Time scaling and how to implement it using
Model 585 is discussed in Chapter 3.
Model 585 Time Scaling Processor Introduction
1-2
Pitch shifting, sometimes referred to in other documents as pitch scaling, alters the
perceived frequency of the audio signal from that of the original signal, while leaving
the duration of the signal the same as the original. Pitch shifting and its
implementation using Model 585 is covered in Chapter 4.
Model 585 Time Scaling Processor
2-1
Chapter 2
Getting Started
This chapter covers connection requirements for Model 585 and the basics of using
the front-panel controls.
2.1 Unpacking and Inspection
Before unpacking Model 585, inspect the outer carton for shipping damage. If the
carton shows damage, inspect Model 585 in the associated areas. The BNC
connectors on the rear panel are covered with protective plastic caps.
The following items are provided with Model 585:
Three power cords: one each for US, continental Europe, and the UK. Use the
cord appropriate to your location.
A bag containing rackmount screws and washers, plus five 75 BNC
terminators.
Warranty information. Fill out the warranty card and return to Dolby
Laboratories. To receive software upgrades, register your product on the
software upgrades page at
www.dolby.com/download/softreg.
2.2 Installing
Installing Model 585 requires:
Two standard rackspace units.
Digital I/O. The digital input and output connections on Model 585 may be
unfamiliar to a first-time user of a digital audio device. The Audio
Engineering Society (AES) created a standard electrical interface for digital
audio with a balanced XLR connector and 110
impedance called AES3-
1995. This interface was later expanded to include an unbalanced BNC
connector, 1 Vp–p signal level, and 75
impedance; it is now known as both
AES3-ID-1995 and SMPTE-276M. Model 585 uses this new standard for
digital audio electrical interface connections.
Note: These signals must be properly terminated with a 75impedance at one point
only. We recommend a standard video terminator.
Model 585 Time Scaling Processor Getting Started
2-2
Cables. We recommend standard 75 BNC cables for digital audio signal
connections. To connect to digital equipment with 110
XLR connectors, use
impedance-matching transformers (readily available from Canare, Neutrik,
and other manufacturers).
Input channel 1/2 must be connected to a valid digital audio signal for proper
operation of the unit.
Model 585 can be used between any two products that carry PCM audio. For specific
installation examples, see Chapter 5, Applications.
2.3 Rear Panel
The main fuse rating is:
T 1A L (1 amp, 250 V, 20 mm, time-lag, low-breaking capacity) for all operating
voltages.
WARNING: Before applying power, check the main fuse, using the procedure
on page viii.
There is no power switch on Model 585. To apply power, connect the power cord to a
live outlet.
2.3.1 Digital Audio Connections
Figure 2-1 shows the digital audio input and output connections.
Ch 7/8Ch 7/8
AES RefAES Ref
Ch 7/8Ch 7/8
Ch 5/6Ch 5/6
Ch 5/6Ch 5/6
Ch 1/2Ch 1/2
Ch 1/2Ch 1/2 Ch 3/4Ch 3/4
Ch 3/4Ch 3/4
Digital
Inputs
Digital
Inputs
Digital
Outputs
Digital
Outputs
1
2
3
Figure 2-1 Connections: Signal In and Out
Model 585 Time Scaling Processor Getting Started
2-3
Figure 2-1 definitions:
1.
Digital Inputs. Model 585 requires PCM audio input at a sample rate of
48 kHz ± 15%. Each input has two connectors; either connector can be used for
the input or as a loop-through for that channel pair. If the loop-through connection
is not being used, it must be fitted with a 75
termination. The last device in the
loop-through signal chain must be terminated with 75
Ω.
Note: Ch 1/2 requires a valid PCM digital audio signal. That input is used to derive
the clocks for all input channels and is the reference clock for scaling.
2. AES Ref. Connect to an AES digital audio reference source. The second connector
can either be used as a loop-through or be terminated, as appropriate.
Note: AES Ref requires a valid AES digital audio signal. That input is used to derive the
clocks for all output channels and so is the reference clock for the digital outputs.
3. Digital Outputs. These connections carry the processed PCM signal.
2.3.2 Serial Connection Ports
Figure 2-2 shows the serial connection ports.
Metadata OutMetadata Out
GP I/O
Remote RS-232
Remote RS-232
Metadata InMetadata In
1
3
2
4
Figure 2-2 Connections: Remote RS-232, GP I/O, Metadata In and Out
Figure 2-2 definitions:
1.
Remote RS-232. Connect to this port to update Model 585 software.
2.
Metadata In. (Reserved for future use.) Input port for external metadata. Connect
to a device that delivers Dolby
®
metadata, such as a Dolby E decoder or Model
DP570 Multichannel Audio Tool.
3.
GP I/O. This port provides a fixed, TTL level-sensitive output indicating the
current status of Model 585.
4.
Metadata Out. (Reserved for future use.) Output port for metadata. Connect to a
downstream Dolby E or Dolby Digital encoder.
Model 585 Time Scaling Processor Getting Started
2-4
2.3.3 Remote Connection Ports
The Remote (9-pin) In and Remote (9-pin) Out ports are reserved for future
enhancements.
2.4 Front Panel
The front panel is shown with feature definitions in Figure 2-3.
Menu display shows the current function mode
Knob
f
or adjustment o
f
settings and menu navigation
Buttons for
function selection, and adjustment of settings
menu navigation,
LEDs indicate when
specific modes are in use
Figure 2-3 Model 585 Front Panel
The menu system has two independent structures: setup and status. The setup menu
lets you control and configure Model 585 to suit your requirements. The status menu
displays information regarding the operating status.
There are two ways to adjust settings on Model 585. All functions are adjustable
using the buttons below the display window, and some functions can be easily
adjusted using the knob.
Model 585 Time Scaling Processor Getting Started
2-5
2.4.1 Reading the Display
After powering up, Model 585 displays the main status menu.
The factory default is:
5.1 + 2 Sens=5
+0.0
The main status menu shows you:
On the upper line, the program configuration and the sensitivity level. In this
example,
5.1 + 2 defines two programs: Program 1, a 5.1 mix; and
Program 2, a two-channel mix. The sensitivity level is set to 5.
The amount of pitch shifting on the lower line, +0.0%, indicates no shift.
2.4.2 Buttons
The six buttons in Figure 2-4 display window control navigation through the menus
and selection of parameters within menu screens. Press any button to use the
command listed below it.
Esc
Enter
Setup
Setup
Shift
Status Bypass
Figure 2-4 Front-Panel Buttons
Note: In the Transport menu, some buttons are redefined to trigger functions not
available in all other menus. For more details, see Section 3.1, Transport
Menu.
Model 585 Time Scaling Processor Getting Started
2-6
Table 2-1 Front-Panel Button Definitions
Button Result
Shift
Selects the alternate function for a button. To select Status or Bypass,
hold down
Shift and press the button under the selection you want.
Setup
From any status menu, displays the last setup menu viewed, or the
Unit
Setup
menu if a setup menu has not been viewed in the previous five
minutes. From any setup menu, displays the
Unit Setup menu.
Status
From any setup menu, displays the last status menu viewed, or the main
status menu if a status menu has not been viewed in the previous five
minutes. From any status menu, displays the main status menu (program
configuration and amount of pitch shift).
Scrolls to previous item in menu selection display. In menus that
determine a numeric value, increases that value.
Scrolls to next item in menu selection display. In menus that determine a
numeric value, decreases that value.
Enter
Activates the menu or setting on the lower line of the display.
Esc
Reverts to the next-higher menu level, or if the active setting is different
from the setting on screen, returns the display to the active setting.
Bypass
Activates bypass mode. Processing latency remains in effect, but no
adjustments are made to the output signal.
To take the unit out of bypass mode, press
Shift + Bypass again.
Note: In all menus, settings other than the active one display a flashing block next to
the setting. Press Enter to select the setting shown, or Esc to return to the
active setting.
2.4.3 Knob
The knob offers quick adjustment of many menu options.
Rotating clockwise scrolls through setup menu options in the same way as pressing
. Rotating counterclockwise scrolls through setup menu options in the same way
as pressing
.
In the main status menu, you can adjust the pitch shift value by turning the knob.
Pressing
Shift while turning the knob changes the sensitivity level. Pressing either
arrow button scrolls to other status menu displays.
Model 585 Time Scaling Processor Getting Started
2-7
Caution: Adjusting the pitch shift value or sensitivity level in the main status menu
activates that value change immediately; pressing Enter is not required.
You do not have the option to press Esc to return to the original setting, so
note what that setting is before rotating the knob.
In the Play menu, the knob triggers different functions than in all other menus. See
Knob Function in Play Menu on page 3-4 for details.
2.5 Status Menu
The main status menu, showing the current program configuration and pitch shift
percentage, appears when you turn the power on. At power-up, the status returns to
the configuration that was active at the preceding power-down.
When you press the
Status button combination (Shift + Status) while in a setup menu,
the display returns to the last status menu displayed within the previous five minutes.
If that is not the main status menu, you can view that menu by pressing
Esc, or the
Status button combination again.
In the main status menu, you can view more information about the current settings by
using the arrow buttons. Press
to view the next choice, or to view the
previous choice. Table 2-2 defines all the status menus.
Table 2-2 Status Menu Screens
Menu Definition
Main Status Shows program configuration and pitch shifting value.
Firmware Version
Shows version number of firmware loaded on Model 585.
Digital In
Enter to see status of the input signal for each channel pair.
Reference In
Shows status of the AES Reference signal.
Note: There is no indication of the condition of the reference or digital input signals
on the front panel or the main status menu. The status of these signals is only
available through the individual status menus.
Model 585 Time Scaling Processor Getting Started
2-8
2.6 Setup Menu
Options in the setup menu are:
Program Config
Operating Mode
Transport
System Settings
Press Enter to view the menu for the option on the second line of the display. The
Transport menu operates the time scaling function, and is described in Section
3.1, Transport Menu. The other three menus are described in this section.
2.6.1 Program Configuration
The Program Config menu initially displays the active program configuration.
Rotate the knob or press an arrow button to scroll through the other configuration
options. To process the input signal properly, the
Program Config setting must
match the configuration of the input signal.
The
Program Config setting describes how the eight input channels are
configured. The notation conventions are as follows:
The
+ symbol separates individual audio programs within a configuration. For
example,
5.1 + 2 represents one 5.1-channel and one stereo program—which may
or may not be related. The
× symbol shows the number of a given channel format
within that configuration. For example,
4 × 2 represents four two-channel
programs—again, which may or may not be related. One configuration has four
different programs:
4 + 2 + 2 × 1, which is one four-channel, one two-channel,
and two mono programs.
The
Program Config parameter instructs Model 585 which input channels to
process together as a single, phase-coherent program. For example:
5.1 Processes the first six input channels as one complete 5.1-channel audio
program.
5.1 + 2 Processes the first six input channels as one complete 5.1-channel audio
program. Processes channels 7 and 8 as one complete stereo program.
4 × 2 Processes channel pairs 1/2, 3/4, 5/6, and 7/8 as four separate stereo
programs.
Model 585 processes all program configurations to the same high quality. Therefore,
there is no difference in audio performance between
2 + 2, 3 × 2, or 4 × 2
program configurations.
Model 585 Time Scaling Processor Getting Started
2-9
Channel assignments within each program configuration follow standard mapping, as
shown in Table 7-1 in Chapter 7, Reference Data. The only exception is the low-
frequency effects (LFE) channel, which can also be assigned manually, as described
in Section 2.6.2, Operating Mode.
2.6.2 Operating Mode
In the Operating Mode menu, you have six options: Sensitivity, Pitch,
Processing Delay, Clock Source, DC Filter, and LFE Channel.
Sensitivity
Model 585 is able to perform high-quality time scaling of complex audio material
because, in a manner comparable to that used by human listeners, it analyzes and
identifies the individual audio components and processes them independently. The
Sensitivity setting allows you to adjust the level of processing detail Model 585
applies to the audio material. The default setting, 5–high, provides the most detailed
processing and is appropriate for nearly all material.
For some material, however, the 5–high setting may be too sensitive, causing
Model 585 to focus on subtle audio elements that can interfere with the processing of
the most prominent material. In this case, Model 585 may not produce its best results.
For example, if material with a live audience is being processed and the
Sensitivity setting is too high, Model 585 may focus on elements of audience or
ambient sounds to the detriment of the primary audio material.
As you decrease the Sensitivity setting, less prominent elements of the audio
material are processed less intensively, reducing the impact on the most prominent
elements. If the Sensitivity setting is too low, however, important elements of
the audio may not be processed correctly.
The Sensitivity setting can be adjusted in real time using the front-panel
controls.
If you alter the setting using the Sensitivity submenu, you are able to “cue up”
different settings. For example, you can be processing audio at one setting, select a
new setting and then press enter to activate the new setting as required.
In addition to adjusting this setting directly within the Sensitivity submenu, you
can also make the adjustment from the main status menu by rotating the knob while
pressing Shift. If you do so, however, the adjustment is immediately activated, and
you cannot return to the previous value by pressing Esc.
Model 585 Time Scaling Processor Getting Started
2-10
Note: Sensitivity should remain at 5–high for most program material. If the
setting must be changed, the change should be limited to the length of the
specific passage that requires the change, and then returned to 5–high.
Setting changes activate in real time when changed using the front-panel
controls.
Pitch
You can use the Pitch menu to select a new scaling value by pressing the arrow
buttons or rotating the knob. You can also make this adjustment from the main status
menu by rotating the knob. If you do so, however, the adjustment is immediately
activated, and you cannot return to the previous value by pressing Esc.
Processing Delay
The Processing Delay menu defines the system latency in milliseconds, within
a range of 400–480 ms. The default is 440 ms.
Clock Source
In the Clock Source menu, you can choose the source for the digital audio output
clock. The default is Digital Input, which locks the output clock to the channel
1/2 input. Internal 48 kHz locks the output clock to an internal 48 kHz
oscillator. External Ref-In locks the output clock to the AES Ref input clock.
The status of the AES Ref input clock is displayed in the Reference In status
menu.
DC Filter
The DC Filter can be turned on to eliminate any inconsistency due to the
processing of very low frequency or subsonic sounds. The default is Disabled.
LFE Channel
In the LFE Channel menu, you can adjust the assignment of the LFE channel to
match the input. The factory default is Auto, which assigns all channels according to
the standard channel mapping shown in Table 7-1. If the input to Model 585 includes
a program with an LFE channel assignment not in line with the assignments in Table
7-1, you need to assign the LFE channel manually using this menu. In multichannel
audio, the LFE channel is bandwidth-limited, so to process the complete program
audio properly, the LFE channel must be assigned correctly.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Dolby Laboratories 585 Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue