Sentiotec wave.com4 11kW Manuale utente

Tipo
Manuale utente
EN
DE
FR
IT
INSTRUCTIONS FOR INSTALLATION AND USE
English
NL
SV
FI
RU
Version 03/21 Ident no. 1-050-755
WC4-B-11
WC4-B-D/W/S
Sauna controller
wave.com4 11 kW
wave.com 4 basic module 11 kW 1-049-633 / WC4-B-11
wave.com 4 control unit, dark wood 1-008-128 / WC4-B-D
wave.com 4 control unit, black 1-010-433 / WC4-B-S
wave.com 4 control unit, white 1-010-433 / WC4-B-W
Table of Contents
1. About this instruction manual 5
2. Important information for your safety 6
2.1. Intended use 6
2.2. Safety information for the installer 7
2.3. Safety information for the user 8
3. Product description 9
3.1. Scope of delivery 9
3.2. Not supplied 9
3.3. Optional accessories 9
3.4. Product features 10
3.5. Sauna operating modes 11
3.6. Sensor operating modes 11
4. Installation 13
4.1. Installing the power unit 13
4.2. Installing the main switch 13
4.3. Installing the cabin light and the light switch 13
4.4. Installing the expansion board (optional) 14
4.5. Installing the control unit 14
4.6. Installing the heater sensor F1 with overheat cut-out 15
4.8. Installing the bench sensor F2 (optional) 16
4.9. Installing the humidity sensor WC4-H-H (optional) 16
4.7. Installing the humidity/temperature sensor FTS2 (optional) 16
5. Electrical connection 17
5.1. Connecting the power supply cable and heater 18
5.2. Connecting the evaporator (optional) 18
5.3. Connecting the control unit 18
EN
5.4. Connecting an external main switch 19
5.5. Connecting the light 19
5.6. Connecting an external light switch 19
5.7. Connecting a fan (optional) 19
5.8. Connecting the heater sensor F1 20
5.9. Connecting the humidity/temperature sensor FTS2 (optional) 20
5.10. Connecting the bench sensor F2 (optional) 20
5.11. Connecting the humidity sensor WC4-H-H (optional) 21
5.12. Connecting a dummy sensor (optional) 21
5.13. Connecting a power booster (optional) 21
5.14. Connecting a remote start device 21
5.15. Finishing the installation 22
6. Testing 22
7. Connection diagram 23
7.1. Connection diagram of basic module 23
7.2. Connection diagram for the expansion board (optional) 24
8. Operating and display unit 25
9. Operation 26
9.1. Switching on 26
9.2. Setting the heating time 26
9.3. Setting the language 26
9.4. Switching on the light (cleaning light) 27
9.5. Selecting the operating mode 27
9.6. Starting FIN sauna mode 27
9.7. SwitchingoFIN sauna mode 28
9.8. Starting combined HUM mode 28
9.9. SwitchingocombinedHUM mode 28
9.10. Stopping the post-drying programme 29
9.11. Setting the timer 29
9.12. Dimming the light 29
9.13. Setting the preset time 30
9.14. ECO mode 30
9.15. Activating standby for remote operation 31
9.16. Remote start release 31
9.17. Activating an additional control unit 32
9.18. Setting the acoustic signal 32
9.19. Activating the rolling display 33
9.20. Setting the post-drying programme 33
9.21.Switchingothesaunacontroller 34
10. Cleaning and maintenance 34
10.1. Cleaning 34
10.2. Maintenance 34
11. Disposal 34
12. Troubleshooting 35
12.1. Error messages 35
12.2. Fuses 36
12.3. Temperature correction 36
13. Technical data 37
EN
Instructions for installation and use p. 5/38
1. About this instruction manual
Read these installation and operating instructions carefully and keep them within
reach of the sauna controller. This ensures that you can refer to information on
safety and operation at any time.
Symbols used for warning notices
In these instructions for installation and use, a warning notice located next to
an activity indicates that this activity poses a risk. Always observe the warning
notices. This prevents damage to property and injuries, which in the worst case
may be fatal.
The warning notices contain keywords, which have the following meanings:
DANGER!
Serious or fatal injury will occur if this warning notice is not observed.
WARNING!
Serious or fatal injury can occur if this warning notice is not observed.
CAUTION!
Minor injuries can occur if this warning notice is not observed.
ATTENTION!
This keyword is a warning that damage to property can occur.
Other symbols
This symbol indicates tips and useful information.
These installation and operating instructions can also be found in the down-
loads section of our website: www.sentiotec.com/downloads.
Instructions for installation and use p. 6/38
2. Important information for your safety
The wave.com4 11 kW sauna controller has been manufactured
according to the applicable safety regulations. However, hazards
may arise during use. You should therefore adhere to the following
safetyinformationandthespecicwarningsintheinstallationand
operating instructions. Also observe the safety information for the
devices connected.
2.1. Intended use
The wave.com4 11 kW sauna controller is designed solely for oper-
ating and controlling the functions described in the technical data.
The sauna controller may only be used for operating and controlling
three heating circuits with a maximum output of 3.7 kW per heating
circuit.
When using the optional wave.com4 expansion board (WC4-H-PCB),
the maximum evaporator output is 3.0 kW.
According to EN 60335-2-53 sauna remote control units may only be
used to regulate and control a sauna heater that passes the cover test
according to paragraph 19.101. Alternatively, an appropriate safety
measure (e.g.: safety shutdown, door contact...) must be installed.
Any use exceeding this scope is considered improper use. Improper
use can result in damage to the product, severe injuries or death.
The warranty is void if the device is not used as intended.
EN
Instructions for installation and use p. 7/38
2.2. Safety information for the installer
● Theelectricalconnectionmayonlybeperformedbyaqualied
electricianorsimilarlyqualiedperson.Pleasenotethatinthe
event of a guarantee claim, a copy of the invoice issued by
the electrician performing the work must be presented.
Work on the sauna controller may only be performed when the
power has been disconnected.
A fully disconnecting all-pole isolating device compliant with
overvoltagecategoryIIImustbettedonsite.
The power unit of the wave.com4 11 kW (WC4-B-11) must be
installed in accordance with the technical data.
The control unit can be installed inside or outside the sauna,
however it must be mounted according to the installation and
operating manual provided.
Also comply with the regulations applicable at the installation
location.
For your own safety, consult your supplier in the event of prob-
lemsthatarenotexplainedinsucientdetailintheinstallation
instructions.
Instructions for installation and use p. 8/38
2.3. Safety information for the user
The sauna controller must not be used by children under 8 years
of age.
The sauna controller may be used by children over 8 years of
age, by persons with limited psychological, sensory or mental
capabilities or by persons with lack of experience/knowledge,
but only if:
They are supervised.
They have been shown how to use the device safely and
are aware of the hazards that could occur.
Children must not play with the sauna controller.
Children under 14 years of age may only clean the sauna con-
troller if they are supervised.
● Forhealthreasons,donotusethesaunawhenundertheinu-
ence of alcohol, medication or drugs.
● Makesurethatnoammableobjectshavebeenplacedonthe
sauna heater before the sauna controller is switched on.
● Makesurethatnoammableobjectshavebeenplacedonthe
sauna heater before activating the preset time function or the
standby mode for remote start.
For your own safety, consult your supplier in the event of problems
thatarenotdescribedinsucientdetailintheuserinstructions.
EN
Instructions for installation and use p. 9/38
3. Product description
The wave.com4 11 kW is a two-piece sauna controller. In order to function, a basic
module with power unit (WC4-B-11), a control unit (WC4-B-S, WC4-B-D or WC4-
B-W) and a heater sensor (WC4-B-F1D or WC4-B-F1H) are always required.
3.1. Scope of delivery
Power unit (1-049-633 / WC4-B-11)
Installation and operation manual
3.2. Not supplied
Main switch (standard 230 V switch)
Light switch (standard 230 V switch)
Dark wood control unit (1-008-128 / WC4-B-D)
or black control unit (1-010-389 / WC4-B-S)
or white control unit (1-010-437 / WC4-B-W)
Light wood heater sensor (1-013-651 / WC4-B-F1H), 5 m sensor cables
or dark wood heater sensor (1-003-479 / WC4-B-F1D), 5 m sensor cables
3.3. Optional accessories
Expansion board for humidity, bench sensor (1-003-472 / WC4-H-PCB)
Dark wood WC4 bench sensor (1-003-295/WC4-H-F2D), 5 m sensor cables
Light wood WC4 bench sensor (1-013-662/WC4-H-F2H), 5 m sensor cables
Dark wood humidity sensor (1-003-364 / WC4-H-HD), 5 m sensor cables
Light wood humidity sensor (1-013-669 / WC4-H-HH), 5 m sensor cables
Humidity/temperature sensor (1-010-081/O-FTS2), 6 m sensor cables
Dark wood sensor housing for FTS2 (1-041-521 / SC-FTS2-D)
Light wood sensor housing for FTS2 (1-041-520 / SC-FTS2-D)
Y-adapter RJ10 4-pin (1-028-167 / WC4-C-ADY)
Power booster (1-008-779 / O-S2-18, 1-009-280 / O-S2-30)
Safety shutdown (SFE-xxxxx)
Remote start system (1-051-003 / FS-SY)
Door sensor system (1-052-722 / SAB00102)
Instructions for installation and use p. 10/38
3.4. Product features
The wave.com4 11 kW sauna controller features the following functions:
Regulation of sauna heaters with a heating output of up to 11 kW.
When an expansion board is installed, regulation of combined heaters with
a heating output of up to 11 kW and evaporator output of up to 3 kW.
When a power booster is installed, the maximum power rating of 11 kW can
be increased.
Option to connect external main switch
Option to connect external light switch
Switching and dimming a cabin light (up to 100 W bulb)
Fan regulation (up to 100 W)
Automatic heating time limit
The sauna controller shuts down automatically for safety reasons after the
maximum heating time (1 to 12 hours).
Preset time function (1 to 24 hours)
Acoustic signal for time interval (e.g: time to pour water on stones)
Post-drying program
After operation in combined mode, the post-drying program starts automatically
to prevent mould or rot from forming in the sauna cabin. (3 setting options).
Remote start function
Eco mode
Eco mode ensures that the cabin temperature is the same after a break
(20, 40, 60 minutes).
Overheat cut-out
The overheat cut-out is installed in the housing for the heater sensor. If a de-
fect causes the sauna heater to continue heating after reaching the preferred
temperature,theoverheatcut-outswitchesthesaunaheateroatatemper-
ature of around 139 °C.
EN
Instructions for installation and use p. 11/38
3.5. Sauna operating modes
Sauna mode
Dry heat is provided in sauna mode. The temperature in the cabin is high (80 to
100 °C). The humidity is low (no more than 10%).
Combined mode (optional – with expansion board)
In combined mode, the evaporator operates along with the heater. The temper-
ature in the sauna cabin is lower (around 40 to 65 °C) than in sauna mode, but
the relative humidity is much higher, ranging from 35% to 70%. The maximum
humidity that can be set depends on the temperature of the sauna. The higher
the sauna temperature, the lower the maximum humidity level that can be set
(see Fig. 1).
3.6. Sensor operating modes
The wave.com4 11 kW sauna controller can be operated with one, two or three
sensors.
Single sensor mode (F1)
Single sensor mode is the factory setting.
In single sensor mode, the sauna controller is operated with the heater sensor
with overheat cut-out only.
The sauna controller displays the actual temperature by default. The target
temperature is displayed while the setting is entered.
In single sensor mode, the maximum humidity that can be set (optional – with
expansion board) is based on the temperature above the heater and the humidity
is timed. Only the setpoint for the humidity (in % relative humidity) is shown on
the sauna controller display. The actual humidity in the sauna cabin when the
humidity is timed depends on the size of the cabin and the evaporator output,
andmaydierfromthesetpoint.
0
10
20
30
40
50
60
70
80
90
100
010 20 30 40 50 60 70 80 90 100 110
Temp
Feuchte
Fig. 1: Characteristic curve showing humidity relative to temperature
Humidity [%]
Temperature [°C]
Instructions for installation and use p. 12/38
Two-sensor mode with humidity/temperature sensor (FTS2)
(optional – with expansion board)
In two-sensor mode with humidity/temperature sensor, the sauna controller
displays the temperature measured by the humidity/temperature sensor as the
actual temperature.
In two-sensor mode with humidity/temperature sensor, the evaporator is regulat-
ed according to the humidity level measured in the cabin. The sauna controller
displays the actual humidity (in % relative humidity) in the sauna cabin.
Two-sensor mode with bench sensor (F2)
(optional – with expansion board)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna controller displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the setpoint
for the humidity (in % relative humidity) is shown on the sauna controller display.
The actual humidity in the sauna cabin when the humidity is timed depends on
thesizeofthecabinandtheevaporatoroutput,andmaydierfromthesetpoint.
Two-sensor mode with humidity sensor (WC4-H-H)
(optional – with expansion board)
In two-sensor mode with humidity sensor, the sauna controller displays the tem-
perature measured by the heater sensor as the actual temperature. The evap-
orator is regulated according to the humidity measured in the cabin. The sauna
controller displays the actual humidity (in % relative humidity) in the sauna cabin.
Three-sensor mode with bench sensor (F2) and humidity sensor (WC4-H-Hx)
(optional – with expansion board)
In three-sensor mode with bench sensor and humidity sensor, the sauna controller
displays the temperature measured by the bench sensor as the actual temperature.
In three-sensor mode, the evaporator is regulated according to the humidity
measured in the cabin. The sauna controller displays the actual humidity (in %
relative humidity) in the sauna cabin.
EN
Instructions for installation and use p. 13/38
4. Installation
During installation observe the technical data; see Page 37:
4.1. Installing the power unit
See Fig. 2 on Page 14.
ATTENTION!
Damage to the unit
The sauna controller is resistant to splashing water, but direct contact with water
could still damage it.
Install the sauna controller in a dry place where the maximum humidity will
not exceed 95%.
When installed in the sauna cabin, the cable bushings must not point upwards!
The sensors may only be connected using the sensor cables supplied
with the unit, which are heat-resistant up to 150 °C.
The heater sensor cables may NOT be longer than 10 m.
Outside the cabin, the sensor cables can be extended using cables
that are not temperature-resistant.
ATTENTION!
Interference can impair signal transmission
Route all sensor cables separately from other mains cables and control cables.
Protect cables with only one layer of insulation by using a conduit (double
insulation).
To install the power unit 1, carry out the following steps:
1. Takeothecoverofthepowerunit.
2. You can fasten the power unit to the supporting surface at the 4 corners of
the chassis (see arrows Fig. 4 on page 17)
4.2. Installing the main switch
Follow the operating instructions for the switch.
4.3. Installing the cabin light and the light switch
Follow the operating instructions for the switch.
Installation instructions, only for experts p. 14/38
Fig. 2: Wave.com4 11 kW power unit
Basic module
WC4-B-11
Expansion board
WC4-H-PCB
(optional)
4.4. Installing the expansion board (optional)
1. Connecttheexpansionboardtothebaseboardusingthepre-congured
cables (L-N-PE) and the ribbon cable.
2. Fasten the expansion board in place using the screws provided.
4.5. Installing the control unit
Install the control unit 2 on the cabin wall no more than 10 metres from the power
unit 1. Pay attention to how the data cable is routed.
ATTENTION!
Damage to the unit
The control unit 2 for the sauna controller is splash-proof (IP code IPX4).
Only use a manual screwdriver for installation. Using a cordless screwdriver
may irreparably damage the housing.
For installation inside the sauna cabin, maintain a distance of at least 30 cm
to the ceiling.
1. Cut the recess for the control unit, for example using a Ø 70 × 35 mm hole
cutter.
2. Connect the 4-pin plug to the RJ10 socket on the control unit.
3. Screw the housing to the cabin wall by screwing the 4 wood screws supplied
through the hole.
EN
Installation instructions, only for experts p. 15/38
4.6. Installing the heater sensor F1 with overheat cut-out
Note the following points when installing the heater sensor:
The heater sensor must be installed in the sauna cabin above the middle of
the sauna heater. For cabins up to 2 × 2 m a distance of 19 cm from the cabin
wall must be maintained, for larger cabins a distance of 35 cm.
Theheatersensormustbeinstalledinsuchawaythatitisnotaectedby
inowingair.
Fig. 3: Installing the sensor
To install the heater sensor, carry out the following steps (see Fig. 3):
1. Drill through the cabin ceiling with an 8 mm bit.
2. Pull the two 2-core heater sensor cable through the hole.
3. Fasten the sensor housing using the wood screws supplied.
4. Guidethetwo2-coreheatersensorcablesuptothepowerunitandx
the heater sensor cables with cable clamps.
5. Checkthattheheatersensorisrmlyfastened.
Take care not to damage any of the sensor cables when pulling them in.
19 cm
35 cm
> 2 × 2 m
< 2 × 2 m
150 cm
F1
WC4-H-H
Installation instructions, only for experts p. 16/38
4.8. Installing the bench sensor F2 (optional)
The bench sensor must be installed on the wall of the cabin above the rear bench
seat. A distance of about 15 cm from the ceiling of the cabin must be maintained.
To install the bench sensor, carry out the following steps:
1. Drill through the cabin wall with an 8 mm drill bit.
2. Pull the 2-core bench sensor cable through the hole.
3. Fasten the sensor housing using the wood screws supplied.
4. Guide the 2-core bench sensor cable up to the power unit and fasten it with
cable clips.
5. Checkthatthebenchsensorisrmlyfastened.
4.7. Installing the humidity/temperature sensor FTS2
(optional)
The humidity/temperature sensor must be installed on the wall of the cabin above
the rear bench seat. A distance of about 15 cm from the ceiling of the cabin must
be maintained. Follow the installation instructions for the sensor.
A wooden housing is optionally available for the humidity/temperature
sensor.
4.9. Installing the humidity sensor WC4-H-H (optional)
The humidity sensor must be installed in the middle of the side wall furthest from
the heater at a height of around 150 cm (Fig. 3 on page 15).
To install the humidity sensor, carry out the following steps:
1. Drill through the cabin wall with an 8 mm drill bit.
2. Pull the 3-core humidity sensor cable through the hole.
3. Fasten the sensor housing using the wood screws supplied.
4. Guide the 3-core humidity sensor cable up to the power unit and fasten it
with cable clips.
5. Checkthatthehumiditysensorisrmlyfastened.
EN
Installation instructions, only for experts p. 17/38
5. Electrical connection
4
k
i5
7
a
c RJ10 socket for control unit data cable
d Terminal strip for remote strip
e Bushing for RJ10 data cable, F1/F2 sensors
and remote start device
f Terminal strip for F1 sensor
g Bushing for WC4-H-H / FTS2 sensor
h
Terminal strip for F2 / WC4-H-H / FTS2 sensor
i Bushing for fan cable
j Low voltage connection area
k Bushing for evaporator cable
l Terminal strip for evaporator cable and fan
1 230 V / 400 V connection areas
2 Terminal strip for power supply cable
3 Earth rail
4 Bushing for power supply cable
5 Bushing for heater cable
6 Terminal strip for heater cable
7 Bushing for light and power booster
8 Terminal strip for light
9 Terminal strip for light switch
a Bushing for light switch and main switch
b Terminal strip for main switch
1
2
3
6
8
9
b
c
d
e
f
g
h
l
j
Fig. 4: Electrical connection
Installation instructions, only for experts p. 18/38
5.1. Connecting the power supply cable and heater
1. Guide the power supply and heater cable through the bushings 4 and 5
into the 230 V/400 V connection area 1.
2. Connect the cables to the corresponding terminal strips 2 and 6.
Follow the operating instructions for each device.
5.2. Connecting the evaporator (optional)
1. Guide the evaporator cable (optional with expansion board) through
the bushing k into the 230 V/400 V connection area 1.
2. Connect the cables to the corresponding terminal strips l.
Follow the operating instructions for the evaporator.
If the evaporator does not have an automatic low-water indicator, use
a jumper to connect terminal “U1” to terminal “WM” or change the setting
of the acoustic signal (see Page 32).
5.3. Connecting the control unit
1. Guide the control unit connection cable through the bushing e into the
low-voltage connection area j.
2. Connect the plug of the RJ-10 cable to the connection socket c.
The wave.com4 11 kW sauna controllers allow up to 4 control units to
be operated on one power unit. Use the Y-adapter (see “3.3. Optional
accessories” on page 9) to connect the optional control units.
Note “5. Electrical connection” on page 17 and “7.1. Connec-
tion diagram of basic module” on page 23 and “7.2. Connection
diagram for the expansion board (optional)” on page 24.
EN
Installation instructions, only for experts p. 19/38
5.4. Connecting an external main switch
The main switch is not included on delivery.
1. Guide the main switch connection cable through the bushing a into
the 230 V/400 V connection area 1.
2. Connect the cable to terminal strip b. Follow the operating instructions
for the switch.
5.5. Connecting the light
1. Guide the light cable through the bushing 7 into the 230 V/400 V connec-
tion area 1.
2. Connect the light cable to terminal strip 8. Follow the operating instructions
for the switch.
5.6. Connecting an external light switch
The light switch is not included on delivery.
3. Guide the light switch connection cable through the bushing a into
the 230 V/400 V connection area 1.
4. Connect the cable to terminal strip 9. Follow the operating instructions
for the switch.
5.7. Connecting a fan (optional)
1. Guide the fan cable through the bushing i into the 230 V/400 V connec-
tion area 1.
2. Connect the fan cable to terminal strip l. Follow the operating instructions
for the fan.
The contacts are bridged on delivery. Remove the wire jumper for in-
stallation
Installation instructions, only for experts p. 20/38
5.8. Connecting the heater sensor F1
1. Guide the heater sensor cables through the bushing e into the low-voltage
connection area j.
2. Connect the red heater sensor wires (STB) to the terminals labelled “R-R
in terminal strip f.
3. Connect the white heater sensor wires (F1) to the terminals labelled “W-W
in terminal strip f.
5.9. Connecting the humidity/temperature sensor FTS2
(optional)
1. Guide the sensor cables through the bushing g into the low-voltage con-
nection area j.
2. Connect the temperature sensor wires to the terminals labelled “FTS2: sw-br
in terminal strip h.
a. Connect the black wire to the terminal labelled “sw”.
b. Connect the brown wire to the terminal labelled “br”.
3. Connect the humidity sensor wires to the terminals labelled “FTS2: gn-or-rt
in terminal strip h.
c. Connect the green wire to the terminal labelled “gn”.
d. Connect the orange wire to the terminal labelled “or”.
e. Connect the red wire to the terminal labelled “rt”.
5.10. Connecting the bench sensor F2 (optional)
1. Guide the bench sensor cables through the bushing e into the low-voltage
connection area j.
2. Connect the bench sensor wires to the terminals labelled “F2: ws-ws” in
terminal strip h.
For timed humidity in single-sensor mode, the dummy sensor must be
installed (see 5.12 on page 21).
For timed humidity in two-sensor mode (F1 and F2), the dummy sensor
must be installed (see 5.12 on page 21)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308

Sentiotec wave.com4 11kW Manuale utente

Tipo
Manuale utente