Name Display Description Value
selection
Display Initial
value
Description
don Dark switching: The switching
output switches off when the
object is closer than the
taught sensing range.
Stb The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Light
switching functionality.
Std The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Dark
switching functionality.
AVG AUG Setting the moving arithmetic
average
1, 4, 16,
64, 256
64 64 Sets the number of values
across which a moving arith‐
metic average is established
when the signal is output.
This smooths the signal out‐
put. The possible values are
1, 4, 16, 64, or 256 (e.g., 1 =
no averaging, 256 = average
across 256 values)
RST rSt Reset to factory settings NO, YES no X No reset.
YES Reset all values to factory set‐
tings with the exception of the
PNP/NPN selection.
DSP dSP Display settings ON, OFF on X Display shows display value in
cm.
oFF Display switches off 30 sec‐
onds after an operating but‐
ton was last pressed.
DLY dLY Setting the time functions for
the switching outputs.
OFF, OFD,
OND, SHT
oFF X No time function activated.
oFd Switch-off delay, adjustable
from 0 … 999 ms.
ond Switch-on delay, adjustable
from 0 … 999 ms.
Sht Single shot, adjustable from 0
… 999 ms.
Q_1 q_I Distance assignment for
switching output Q1.
0 … 300 300 300 Value range 0 … 300
Q_2 q_2 Distance assignment for
switching output Q2.
0 … 300 300 300 Value range 0 … 300
Q_3 q_3 Distance assignment for
switching output Q3. (only in
5-pin devices)
0 … 300 300 300 Value range 0 … 300
OFS oFS Defines the offset of the
switching threshold (cm) dur‐
ing the teach-in, based on the
currently measured value.
-50 … +50 0 0 Value range -50 … +50
4 CONFIGURATION
10
8020034.ZX33 | SICK
Subject to change without notice