Lindy 42616 Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (JULY 2010)
USB 2.0 Data Transfer Cable
User Manual English
LINDY No. 42615 – PC Version
LINDY No. 42616 – PC & Mac Version
www.lindy.com
User Manual English
- 1 -
Introduction
Thank you for purchasing the USB 2.0 Data Transfer cable, this cable enables you to quickly move data
between your computers, without the need to install drivers or software, everything you need is included in
the cable! Data can be transferred to and from computers running any combination of the supported
operating systems.
PC Version
Windows 2000
Windows XP
Windows Vista
Windows 7
PC & Mac Version
Windows 2000
Windows XP
Windows Vista
Windows 7
Mac OS X 10.4 or above
Package Contents
USB 2.0 Data Transfer Cable
This Manual
System Requirements
PC Version
Windows
®
2000/XP/Vista/7
PC & Mac Version
Windows
®
2000/XP/Vista/7, Mac OS X 10.4 or above
An available USB Port (on each computer)
Features
Allows easy bi-directional data transfer between two computers
Fast data transfer rate of up to 16MByte/s
Simple plug and play installation, no additional drivers required
Integrated software provides an easy to use interface for data transfer
Cable Length: 1.8m
Additional Features of the PC & Mac Version
File/Folder Synchronisation
Outlook Synchronisation
Internet connection sharing
Optical Disk Drive sharing
User Manual English
- 2 -
Installation
PC Version
1. Simply attach the Data Transfer Cable to an available USB port on each of the computers you want
to connect
2. When using Windows 2000/XP, the cable will automatically be detected and the EasySuite file
transfer interface will open, you may now start to use the application
3. When using Windows Vista/7, the cable will automatically be detected and you will be presented
with the following
4. Double click Run EasySuite.exe
5. You will the encounter a User Account Control, click Allow/Yes to start the installation
PC & Mac Version
1. Simply attach the Data Transfer Cable to an available USB port on each of the computers you want
to connect
2. When using Windows 2000/XP, the cable will automatically be detected and the “GoSuite” interface
will open, you may now start to use the application
3. When using Windows Vista/7, the cable will automatically be detected and you will be presented
with the following
4. Select Open folder to view files
5. You will the encounter a User Account Control, click Allow/Yes to start the installation
6. When using Mac OS X, a GoSuite CD Icon will appear on your desktop, double click it
7. The GoSuite folder will open, double click on the GoBridge icon to start the application
User Manual English
- 3 -
Operation
PC Version
Once both computers have been connected to the data cable and the application has started on both
computers you will be presented with the EasySuite interface below:
This interface allows you to transfer data between the connected computers. The screen is split in two,
showing a local and remote computer, enabling the easy navigation of both computers’ file structure
PC & Mac Version
Once both computers have been connected to the data cable and application has started on both
computers you will be presented with the GoSuite interface below:
Simply click on the application you want to use. Please note, only one application can be used at a time
Go! Bridge
When you open the Go! Bridge application you will be presented with the following interface on the
computer you are working on:
For manual data
transfer between two
computers
Share an internet connection
or Optical
Drive between two computers
Synchronise user defined folders
between two computers
Synchronise Outlook data (Inbox,
Contacts, etc) between two computers
User Manual English
- 4 -
This interface gives you access to the file structure of the remote computer, allowing you to transfer data
between the connected computers
To navigate the file structure of the remote computer use the buttons indicated below to switch between
drives and to go forward and back then double click on the files and folders to open them
Remote Share
When you open the Remote Share application you will be presented with the following interface on the
computer you are working on. Click on the option you would like to use
Share CD-Drive
After choosing this option the computer will establish a connection to the drive of the remote computer.
Once the connection is completed you will see the following message to show that the drive is now
available through Windows Explorer, where it appears as a network drive
Share Internet Connection
After choosing this option you will see the following message whilst your computer establishes a connection
to the remote computers’ internet connection
Navigation button
Navigation button
Back/Forward
buttons
User Manual English
- 5 -
Once the message disappears you will receive notification via your computers’ system tray that you are
now connected to the internet
Folder Synchronisation
After choosing this option you will be presented with the following screen. Click the Add button to create a
new Sync Task
After creating a Sync task, simply click the Sync This Task button to being the Synchronisation of data
Add Task
button
3. Choose the
to use:
a) Synchronise in both directions
b) Synchronise Local to Remote
c) Synchronise Remote to Local
1.
Give the task
a name
2.
Choose the folders
you want to S
ync
on both computers
a b c
User Manual English
- 6 -
Outlook Sync
After choosing this option you will be presented with the following screen
6. Click Start to begin the Outlook Sync. Please Note: If Outlook is open on either the local or remote
computers you will receive a dialog box advising that they will be closed down to allow the Sync to take
place
1. Choose the direction to sync
2. Choose what to sync
3. Choose whether to sync other folders
4. Choose whether to overwrite data and
configure the email account type and settings
5. Choose the time period to sync, and which
emails should be included in the sync
Recycling Information / Radio Frequency Energy, Certifications
WEEE (Waste of Electrical and Electronic Equipment),
Recycling of Electronic Products
United Kingdom
In 2006 the European Union introduced regulations (WEEE) for the collection and recycling of all waste electrical
and electronic equipment. It is no longer allowable to simply throw away electrical and electronic equipment.
Instead, these products must enter the recycling process.
Each individual EU member state has implemented the WEEE regulations into national law in slightly different
ways. Please follow your national law when you want to dispose of any electrical or electronic products. More
details can be obtained from your national WEEE recycling agency.
Germany / Deutschland
Die Europäische Union hat mit der WEEE Direktive umfassende Regelungen für die Verschrottung und das
Recycling von Elektro- und Elektronikprodukten geschaffen. Diese wurden von der Bundesregierung im Elektro-
und Elektronikgerätegesetz ElektroG in deutsches Recht umgesetzt. Dieses Gesetz verbietet vom 24.März 2006
an das Entsorgen von entsprechenden, auch alten, Elektro- und Elektronikgeräten über die Hausmülltonne! Diese
Geräte ssen den lokalen Sammelsystemen bzw. örtlichen Sammelstellen zugeführt werden! Dort werden sie
kostenlos entgegen genommen. Die Kosten für den weiteren Recyclingprozess übernimmt die Gesamtheit der
Gerätehersteller.
France
En 2006, l'union Européenne a introduit la nouvelle réglementation (DEEE) pour le recyclage de tout équipement
électrique et électronique.
Chaque Etat membre de l’ Union Européenne a mis en application la nouvelle réglementation DEEE de manières
légèrement différentes. Veuillez suivre le décret d’application correspondant à l’élimination des déchets électriques
ou électroniques de votre pays.
Italy
Nel 2006 l’unione europea ha introdotto regolamentazioni (WEEE) per la raccolta e il riciclo di apparecchi elettrici
ed elettronici. Non è più consentito semplicemente gettare queste apparecchiature, devono essere riciclate. Ogni
stato membro dellEU ha tramutato le direttive WEEE in leggi statali in varie misure. Fare riferimento alle leggi del
proprio Stato quando si dispone di un apparecchio elettrico o elettronico.
Per ulteriori dettagli fare riferimento alla direttiva WEEE sul riciclaggio del proprio Stato.
Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission
regulations and ensure a suitably high level of immunity to electromagnetic disturbances.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced technician for help
You are cautioned that changes or modification not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
LINDY No. 42615/42616
1
st
Edition, July 2010
www.lindy.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Lindy 42616 Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue