4 Description
2.1 Intended use
Legend of symbols
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
2 Conditions of use
The ZL150N control panel is designed to command two-leaf gate operators of the FLEX line powered by 24 V DC.
Every installation and use other than that specified in this manual is forbidden.
3 Reference standards
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”
“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”
2.2 Application settings
Engineered and built entirely by Came Cancelli Automatici
S.p.A.
The control panel should be powered by 230 V AC, at 50/60
Hz frequency.
The command devices and accessories are powered by 24 V.
Warning! The accessories must not exceed 40 W overall.
Tutte le connessioni sono protette da fusibili rapidi, vedi
tabella.
The card provides and controls the following functions:
- automatic closing after an opening command;
- pre-flashing movement indicator;
- obstacle detections when gate is not moving at any point;
- opening recoil:.
The available command modes are:
- opening/closing;
-opening/closing with maintained action;
- Partial opening;
- total stop.
The photocells, after detecting an obstacle, may trigger:
- the reopening of the closing gate;
- the reopening or partial stop if it is opening;
- a total stop.
Special trimmers regulate:
- the working time for automatic closing;
- the M2 gearmotor closing delay;
- the working time.
You can also connect:
- gate open warning-lamp;
- electro lock.
LB54 board to power gearmotors via batteries in case of power
outages. When power is back on it also recharges them.
Came Cancelli Automatici employs an ISO 9001:2000 certified quality management system and an ISO 14001 environmental
management system. Came entirely engineers and manufactures in Italy.
This product is subjected to the following regulations: see statement of compliance.
Respect cable distances and diameters as shown in the "Cable tyeps and sections" table.
The overall power of the connected motors cannot exceed 96 W.
FUSE TABLE
to protect: fuses for:
Electronic board (line) 1.6 A
Command devices and accessories
(control unit)
1.6 A
Gearmotor and electro-lock 5 A
TECHNICAL DATA
line voltage 230 V - 50/60 Hz
Maximum allowed power load 96 W
power draw when idle 60 mA
maximum power for 24 V accessories 40 W
circuit insulation class
container material ABS
container protection rating IP54
temperatura di esercizio -20 / +55°C