3
42
1
Connection Diagrams
- Disconnect power before connecting the sensor.
- Voltage supply according UL 1310, Class 2
or device shall be protected by an external R/C or listed fuse, rated max.
30 VAC/3A or 24 VDC/4A
Push-Pull &
Teach-In /
IO-Link*
PNP
Complementary
NPN
Complementary
O200.T,
Emitter
1 - Brown BN +Vs
2 - White WH Teach-In*
PNP
Inverted
NPN
Inverted
n.c.
3 - Blue BU 0 V
4 - Black BK
Push-Pull /
IO-Link*
PNP NPN Test
*Only for models with IO-Link or ext. Teach-In
BK (4)
output / IO-Link*
O200
0 V
BU (3)
BN (1)
+V
S
WH (2)
Test: Connect Test to +Vs to deactivate the light emission (O200.T)
n.c.: Not connected
Photoelectric sensors
O200
Baumer Electric AG - CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 - Fax +41 (0)63 739 1144
www.baumer.com
qTarget
®
qTeach
®
EN
DE
FR
IT
ES
CN
07.12.2018 / Version 1.1
Xpress Mode
Models with IO-Link
SSC1/4: Switching Signal Channels
MDC: Excess Gain, Intensity or Switch Counter
(selectable)
Quality: The quality bit signals a weak signal
Alarm: The alarm bit signals a problem with the
confi guration or the functionality of the sensor
Scale: Factor by power of ten, applicable to the value of
the Measurement Data Channel (MDC)
IO-Link Process Data Input
16 8 0
IntegerT(16) IntegerT(8) 8 bit
Measurement
Data Channel
(MDC)
Scale
Baumer specifi c
7 6 5 4 3 2 1 0
SSC4 Alarm Quality SSC1
Available Commands:
Teach-in commands, light emission on/off, Find Me (locating
sensor) and more
Available Parameters:
Switching point, output function, time fi lters, operation modes,
qTeach lock time, teach-mode, LED status indicators,
Teach-In method and more
Available Additional Data:
Switch counter, temperature
Related Models
O200 Models with Xpress Teach:
O200.G (Background suppression sensors)
O200.R (Retro-refl ective sensors)
O200.S (Smart Refl ect Light barriers)
O200.T/E (Through beam aensors (E: Receiver)(T: Emitter))
More Information related to these
products can be found on our website
(CAD, Beamcharts, CoC, Drawings, IODDs …)
www.baumer.com
Mounting Instructions
Background suppression sensors & SmartRefl ect Light barriers
The direct refl ection from glossy or refl ective objects
must not impinge on the receiver. This can be avoided
by slightly tilting the sensor.
It is recommended that the object to be detected
approaches the active area of the sensor from the
side, which avoids malfunctions caused by defl ection
of the light beam at edges.
Sensoren mit Hintergrundausblendung & SmartRelfect Lichtschranken
Bei glänzenden oder spiegelnden Objekten darf der
direkte Refl ex nicht auf den Empfänger fallen. Dies
kann vermieden werden, indem der Sensor leicht
abgekippt wird.
Es ist zu beachten, dass ein zu erfassendes Objekt
sich dem aktiven Bereich
des Sensors von der Seite nähern sollte, dadurch
werden Fehlschaltungen durch Ablenkungen des
Lichtstrahles an Kanten vermieden.
Détecteurs de suppression d’arrière-plan & barrières SmartRefl ect
La réfl exion directe d’une surface brillante ou d’objets
très réfl échissants ne doit pas parvenir au récepteur.
Ceci peut être évité en inclinant un peu le capteur.
Il est recommandé que l’objet à détecter adopte
une approche latérale, ce qui évite les dysfonctionne-
ments liés à la diffraction du faisceau sur les bords.
Fotocellule a soppressione di sfondo e SmartRefl ect
Su superfi ci lucide e rifl ettenti è consigliabile inclinare
leggermente il sensore per evitare refl essi diretti sul
ricettore.
Si raccomanda di installare il sensore in modo che
l’oggetto entri lateralmente nel fascio di luce.
Sensores con supresión de fondo y barreras SmartRefl ect
La refl exión directa sobre objetos brillantes o refl ec-
tantes no debe incidir en el receptor, Ésto se puede
evitar inclinanto ligeramente el sensor.
Se recomienda que el objeto se aproximelateralmente
al sensor, de éste modo se Evitan errores de detec-
ción causados por la refl exión del haz en los bordes.
带背景抑制漫发射和智能反射传感器
光泽或高反光物体的全反射不得反射到接收器. 通过稍
微倾斜传感器可以避免这种情况.
建议被测物从侧面接近传感器的有效区域, 这避免了光
束在边缘处偏转而引起的故障.
Teach-In OK
Teach-In NOK
8
8
X
2
How to activate the Teach-In
- Place tool as shown right or connect
Teach-In wire to +Vs.
- Green LED fl ashes with 2 Hz if tool/Teach-In
is recognized properly.
General Information
- qTeach locks 5 min after power up.
- In teach mode the output changes to 0V.
- During operation the teach wire should be connected to 0V.
- For external Teach-In, connect teach wire to +Vs.
- External Teach-In is always possible (no locking).
1-Point Teach
O200.G:
Place object & activate
Teach-In for >2 sec
O200.R, O200.E:
Completely block the
beam & activate Teach-In
for >2 sec
Factory Reset
(only threshold)
Teach-In Instruction
O200.R, O200.S:
Align the sensor to the
refl ector / reference &
activate Teach-In
for >2 sec
O200.E/T:
Align the emitter to the
receiver & activate
Teach-In for >2 sec
1
2
8
1
8
Tolerance*
Sensing range, Sa
Teach-Position
Sensing direction
+10%*
y
Signal
Threshold
LED Indicators Green Yellow
Power on
Short circuit
Output 1 active
Output 1 signal close
to threshold
Teach-In mode see Teach-In Instruction
LED Indication Legend Operating Mode
LED on
LED fl ashing 1 Hz
LED fl ashing 2 Hz
LED fl ashing 8 Hz
O200.G, Background suppression
sensors
O200.R, Retro-refl ective sensors
O200.T/E, Through beam sensors
O200.S, SmartRefl ect Light barriers Optional Teach-In methods*
Level 1
1-Point Teach 1-Point Teach 1-Point Teach
Confi gurable via IO-Link
Window mode (only O200.G)
Level 1 / 1-Point Teach:
Sets a window of +/- 10%* around the
position of the object
Dynamic Teach-In
(only O200.G, O200.R)
The data aquisition starts immediately
after activating Teach-In by qTeach or
wire and stops as soon as released.
Accepted duration of data aquisition:
2 … 15 sec
The switchpoint or window is defi ned by
the detected min & max value.
Sets the switchpoint at the position of
the object +10%*
Sets the threshold as close to the
measurement value
Teaches the position of the
reference (distance)
Teach-In Description Level 1
EN
*This value is adjustable by IO-Link. Please check the IO-Link manual available on www.baumer.com
1
2
8
1
8
Tolerance*
Sensing range, Sa
Teach-Position
Sensing direction
+10%*
y
Signal
Threshold
LED Indikatoren Grün Gelb
Betriebsanzeige
Kurzschluss
Ausgang 1 aktiv
Ausgang 1 Signal
nahe der Schwelle
Teach-In Modus siehe Teach-In Anweisung
LED Anzeige Legende Betriebsmodus
LED leuchtet
LED blinkt 1 Hz
LED blinkt 2 Hz
LED blinkt 8 Hz
O200.G, Hintergrundausblendung O200.R, Refl exions-Lichtschranken
O200.T/E, Einweg-Lichtschranken
O200.S, SmartRefl ect Lichtschranken Optionale Teach-In Modi
Level 1
1-Punkt Teach 1-Punkt Teach 1-Punkt Teach
Einstellbar per IO-Link
Fenster-Modus (O200.G)
Level 1/ 1-Punkt Teach:
Defi niert ein Fenster à +/- 10% um die
Position des Objektes
Dynamischer Teach-In (O200.G, O200.R)
Ebenfalls verfügbar für den Fenster-Modus.
Die Datenaufnahme startet unmittelbar
nach der Aktivierung des Teach-In und
stoppt, sobald das Teach-In freigegeben
wird.
Akzeptierte Dauer: 2 ... 15 Sek.
Der Schaltpunkt oder das Schaltfenster
wird auf Basis der min. & max. Werten
defi niert.
Setzt den Schaltpunkt an der Position
des Objektes +10%*
Setzt die Schaltschwelle so nah
ans eingelernte Refl ektorsignal wie
möglich.
Lernt die Position der Referenz ein
(Distanz)
Teach-In Beschreibung Level 1
DE
*Dieser Wert kann per IO-Link verändert werden. Weitere Details fi nden Sie im IO-Link Manual verfügbar auf www.baumer.com
Teach-In OK
Teach-In NOK
8
8
X
2
Allgemeine Informationen
- qTeach verriegelt 5 min nach dem Einschalten.
- Im Teachmodus wechselt der Ausgang auf 0V.
- Im Normalbetrieb muss die Teachleitung auf 0V gelegt werden.
- Für externes Teach-In, Teachleitung entsprechend mit +Vs verbinden.
- Externes Teach-In ist immer möglich (keine Verriegelung)
1-Punkt Teach
O200.R, O200.S:
Sensor zu Refl ektor /
Referenz ausrichten
& Teach-In >2 Sek.
aktivieren
O200.E/T:
Sender zu Empfänger
ausrichten &
Teach-In >2 Sek.
aktivieren
O200.R, O200.E:
Den Strahl komplett
blockieren &
Teach-In >2 sec aktivieren
Werkseinstellungen
(nur Schaltschwelle)
Aktivierung des Teach-In
- Platziere das Werkzeug wie rechts gezeigt
oder verbinde die Teachleitung mit +Vs
- Die grüne LED blinkt mit 2 Hz, wenn das
Werkzeug korrekt erkannt wird.
Teach-In Anleitung
O200.G:
Objekt platzieren &
Teach-In >2 Sek.