Fronius 50kA-3 Guida d'installazione

Tipo
Guida d'installazione
Fronius Smart Meter 50kA-3
/ Perfect Charging
/ Perfect Welding
/ Solar Energy
42,0410,2169
EN / DE / IT / FR
002/27082021
Fronius International GmbH
4600 Wels, Froniusplatz 1, Austria
http://www.fronius.com
Fronius Worldwide
www.fronius.com/addresses
Under http://www.fronius.com/addresses you
will nd all addresses of our sales branches
and partner rms!
FR
IT
DEEN
Schemas de raccordement
Schemi d’inserzione
Anschluss-SchemataWiring diagrams
3-2E (1-2)
INPUT
CURRENT
L1
L2
L3
1852
852 3467911
X
X
X
S1
abab
ABAB
P1 S1
P1
Fronius Smart Meter 50kA-3
LOADGRID
6A 6A 6A
3N3E CURRENT
L1
L2
L3
N
1852
852 3467911
X
X
X
S1
an
AN
P1
S1
P1
11
XXX
Fronius Smart Meter 50kA-3
VOLTA GE
INPUT
LOADGRID
6A 6A 6A
Fronius Smart Meter 50kA-3
1N1E
INPUT
CURRENT
L
N
1852
852
3 4 6 7 911
11
LOADGRID
X
S1
ab
AB
P1
6A
3-2E (2-3)
L1
L2
L3
852
abab
ABAB
INPUT
CURRENTVOLTA GE
1852 3 4 6 7 911
X
X
X
6A 6A 6A
S1
P1
P1
S1
Fronius Smart Meter 50kA-3
LOADGRID
3-2E (1-3)
INPUT
CURRENT
L1
L2
L3
1852
852 3467911
X
X
X
6A 6A 6A
S1
abab
ABAB
P1
S1
P1
Fronius Smart Meter 50kA-3
LOADGRID
3-3E
L1
L2
L3
852
abab
ABAB
INPUT
CURRENTVOLTA GE
1852 3 4 6 7 911
X
X
X
S1
P1 S1
P1
P1
S1
Fronius Smart Meter 50kA-3
LOADGRID
6A 6A 6A
OUTPUT
RS 485
Rx / Tx GND
3534332915
+-
Fronius
Inverter
Type 1
120 Ω
ON
D+ D--
* *
Fronius
Inverter
Type 2
120 Ω
ON
M1+ M1-GND
Shield
max. 300 m
OUTPUT
RS 485
Rx / Tx GND
3534332915
+-*supplied with the device
liegt dem Gerät bei
incluso con l’apparecchio
joint á l’appareil
Fronius Smart Meter 50kA-3 è ottimizzato
per la misurazione con trasformatori di
corrente nella rete da 400 V. È possibile
congurare Fronius Smart Meter per utiliz-
zare trasformatori di tensione. La gamma
di tensione non è però adatta ai trasforma-
tori di tensione comunemente disponibili
sul mercato. Fronius non esprime alcuna
raccomandazione per i trasformatori di
tensione adatti.
Modbus transmission
Transmission speed:
9600 baud
Address: 1
Parity bit: none
Follow the operating manual Fronius
Symo Hybrid in the case of hybrid appli-
cations.
Der Fronius Smart Meter 50kA-3 ist für die
Stromwandler-Messung im 400V Netz op-
timiert. Es ist möglich den Smartmeter für
die Verwendung von Spannungswandlern
zu kongurieren. Der Spannungsbereich
passt aber nicht zu den am Markt üblichen
Spannungswandlern. Fronius gibt keine
Empfehlungen für passende Spannungs-
wandler ab.
Modbus Übertragung
Übertragungsgeschwindigkeit:
9600 baud
Adresse: 1
Parity bit: keines
Bei Hybrid-Anwendungen die Bedienungs-
anleitung Fronius Symo Hybrid beachten!
The Fronius Smart Meter 50kA-3 has
been designed to work best as a current
transformer measuring device in a 400-V
grid. It is also possible to congure the
smart meter for use with voltage transfor-
mers. The voltage range is not, however,
compatible with the standard voltage
transformers available on the market.
Fronius is not able to recommend any
suitable voltage transformers.
Transmissione Modbus
Velocità di trasmissione:
9600 baud
Indirizzo: 1
Bit di parità: nessuno
Osservare le istruzioni per l’uso Fronius
Symo Hybrid per applicazioni ibride.
Le Fronius Smart Meter 50kA-3 est optimi-
sé pour les mesures avec transformateur
de courant dans un réseau 400 V. Il est
possible de congurer le Smart Meter
pour l’utilisation de transformateurs de
courant. La plage de tension n’est cepen-
dant pas adaptée aux transformateurs de
courant habituellement disponibles sur le
marché. Fronius ne fournit aucune recom-
mandation concernant les transformateurs
de courant adaptés.
Transmission Modbus
Vitesse de transmission :
9600 baud
Adresse : 1
Bit de parité: none
Respecter les instructions de service
Fronius Symo Hybrid pour les applications
hybrides.
FRITDEEN
Min. Softwareversion
Min. Softwareversion
Min. Softwareversion
Version logiciel mini.
Datamanager 3.7.2 / Energypackage 1.3.3
Specied operating range
Arbeitsbereich
Campo di funzionamento
Plage de fonctionnement
- 5 °C .... + 55 °C
Power consumption
Eigenverbrauch
Consumo di energia
Puissance consommée
2,5 W
Terminal capacity
Anschlussquerschnitt
Caratteristiche Terminali
Section des câbles
0,05 - 4 mm²
Current L1
Strom L1
Corrente L1
Courant L1
Current L2
Strom L2
Corrente L2
Courant L2
Current L3
Strom L3
Corrente L3
Courant L3
Active power
Wirkleistung
Potenza attiva
Puissance active
Reactive power
Blindleistung
Potenza reattiva
Puissance réactive
Apparent power
Scheinleistung
Potenza apparente
Puissance apparente
Linked voltage L1-L2
Verkettete Spannung L1-L2
Tensione concatenata L1-L2
Tension composée L1-L2
Linked voltage L2-L3
Verkettete Spannung L2-L3
Tensione concatenata L2-L3
Tension composée L2-L3
Linked voltage L3-L1
Verkettete Spannung L3-L1
Tensione concatenata L3-L1
Tension composée L3-L1
M T
M T
Total Active Energy Consumed
Verbrauchte Gesamt-Wirkenergie
Energia Acctiva Totale consumata
Consommation Energie Active Totale
Total Reactive Energy
Gesamt-Blindenergie
Energia Reattiva Totale
Energie Rèactive Totale
Total Active Energy ProducedTotal Active Energy Produced
Produzierte Gesamt-WirkenergieProduzierte Gesamt-Wirkenergie
Energia Acctiva Totale prodotta
Produite Energie Active Totale
Partial Reactive Energy
Teil-Blindenergie
Energia Reattiva Parziale
Energie Rèactive Partielle
Active Power Max. Demand
Wirkleistungsmittelwert Max.
Valore Massimo Potenza Attiva Media
Puissance Moyenne Maximale Active
Active Power Demand
Wirkleistungsmittelwert
Potenza Attiva Media
Puissance Moyenne Active
For the Reset keep pressed the key for 5 seconds
Für die Rückstellung, die Taste für 5 Sekunden drücken
Tenere premuto per 5 secondi per l’azzeramento
Pour la Remise à zéro tenir appuyé la touche pour 5 seconds
> 5 s =
RESET
> 5 s
RESET
> 5 s
RESET
> 5 s
Voltages - currents menu
Spannungs- und Strommenü
Menù tensioni - correnti
Menu tensions - courants
2s
1
1
2s
=
Wait for 2 seconds
2 Sekunden warten
Attendere 2 secondi
Attendre 2 secondes
1
1
+
+
+
+
Programming
Password (0001) Passwort (0001)
Kennwort (0001) Mot-clé (0001)
Input
Eingang
Ingresso
Entrée
CT Transformation ratio1)
Übersetzungsverhältnis der Stromwandler1)
(0001 - 99992))
VT Transformation ratio1), 3)
Übersetzungsverhältnis der Spannungswandler
1), 3)
(001,0 - 500,02))
Change (and remember!) password
Kennwort ändern (und merken!)
FRIT
DE
ProgrammationProgrammazione
Programmierung
Es ist ausschließlich das Übersetzungsverhält-
nis der Strom- und Spannungswandler einzu-
stellen. Alle anderen Parameter sind schon
vorab eingestellt.
EN
Only the transformation ratio of the current and
voltage transformer must be set. All other para-
meters have already been set in advance.
Occore impostare esclusivamente il rapporto
di trasformazione del trasformatore di corrente
e di tensione. Tutti gli altri parametri sono già
preventivamente impostati.
Seul le rapport de multiplication du transforma-
teur de tension et de courant doit être para-
métré. Tous les autres paramétres sont déjà
réglés en amont.
Important! Changing the transformation ratios will reset the counters in the Fronius Smart Meter to 0.
Wichtig! Bei Änderung des Übersetzungsverhältnisses werden die Zähler im Fronius Smart Meter auf 0 zurückgesetzt.
Importante! Modicando il rapporto di trasformazione, i contatori in Fronius Smart Meter verranno azzerati.
Important ! En cas de modication du rapport de multiplication, les compteurs du Fronius Smart Meter seront remis à 0.
1)
CT Transformation ratio x VT Transformation ratio = max. 1 000 000
Übersetzungsverhältnis der Stromwandler x Übersetzungsverhältnis der Spannungswandler = max. 1 000 000
Rapporto trasformazione TA x Rapporto trasformazione TV = max. 1 000 000
Rrapport de transformation du TC x Rrapport de transformation du TP = max. 1 000 000
2)
1)
1)
Conversion only with the use of voltage converters (Direct voltage measurement VT = 1)
Umstellung nur bei der Verwendung von Spannungswandlern (Direkte Spannungsmessung VT=1)
Conversione solo con l‘uso di convertitori di tensione (misurazione della tensione diretta VT = 1)
Conversion uniquement à l‘utilisation de convertisseurs de tension (mesure de la tension directe VT = 1)
3)
Rapporto trasformazione TA1)
Rrapport de transformation du TC1)
Rapporto trasformazione TV1), 3)
Rrapport de transformation du TP
1), 3)
Modicare (e annotare!) la password
Modier le mot de passe (et le retenir!)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Fronius 50kA-3 Guida d'installazione

Tipo
Guida d'installazione