Comtech EF Data Memotec NetPerformer SDM-8400 Hardware Installation Manual

Tipo
Hardware Installation Manual
NetPerformer
®
SDM-8400
Hardware Installation Guide
COPYRIGHTS AND DISCLAIMERS
Published Date: February 16, 2017
Document # 1589
This publication contains information proprietary and confidential to Memotec Inc. Any reproduction,
disclosure or unauthorized use of this publication is expressly prohibited except as Memotec Inc. may
otherwise authorize in writing.
Memotec Inc. reserves the right to make changes without notice in product or component design as warranted
by evolution in user needs or progress in engineering or manufacturing technology. Changes which affect the
operation of the unit will be documented in the next revision of the manual.
We have made every effort to ensure the accuracy of the information presented in our documentation.
However, Memotec assumes no responsibility for the accuracy of the information published. Product
documentation is subject to change without notice. Changes, if any, will be incorporated in new editions of
these documents. Memotec may make improvements or changes in the products or programs described within
the documents at any time without notice. Mention of products or services not manufactured or sold by
Memotec is for informational purposes only and constitutes neither an endorsement nor a recommendation for
such products or services.
Memotec Inc. is a wholly owned subsidiary of Comtech EF Data Corp., and its parent company Comtech
Telecommunications Corp (NASDAQ: CMTL).
AccessEMS, CXTool, CX-U Series, CX-UA Series, AbisXpress, NetPerformer, AccessGate, ACTView,
SDM-8400, and the SDM-9000 series of products are either registered trademarks or trademarks of Memotec
Inc.in Canada, the United States of America, and in other countries.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Any other trademarks are the property of their respective companies.
Copyright © 2017 Memotec Inc.
Memotec Inc.
7755 Henri Bourassa Blvd. West
Montreal, Quebec
Canada H4S 1P7
Tel.: (514) 738-4781
FAX: (514) 738-4436
www.memotec.com
Memotec Inc.
Contents
Chapter 1: Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1. 1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.1.1 Sales Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1. 2 About this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.1 Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.2 Instructions to the Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.3 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.4 NetPerformer Document Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.5 Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.6 Request for Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1. 3 Changes to Console Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.3.1 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.3.2 Providing Product Number to Technical Support . . . . . . . . . . . . 1-7
1.3.3 Checking the Contents of Your Product Package . . . . . . . . . . . 1-7
1.3.4 Returning an SDM-8400 Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Chapter 2: Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2. 1 About Unpacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.1 Selecting a Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Size Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.3 Distance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.1.4 Environmental Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2. 2 Preparing the Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.2.1 What You Will Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Chapter 3: Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3. 1 About the Hardware Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3. 2 Installing the Unit in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3. 3 Powering Up the Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.3.1 Connecting the SDM-8400 UAC to an AC Power Source . . . . . 3-5
3.3.2 Connecting the SDM-8400 DC to a DC Power Source . . . . . . . 3-6
3.3.3 System Status on Power-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3. 4 Connecting the Console Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3.4.1 Important Console and Modem Settings for Startup . . . . . . . . . 3-9
3.4.2 Activating the Console Connection . . . . . . . . . . . . . . . . . . . . . . 3-9
Memotec Inc.
3. 5 Installing the Licensed Software Options . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.5.1 Software License Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3. 6 Connecting the LAN Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Chapter 4: Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4. 1 About SDM-8400 Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4. 2 Unit Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2.1 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2.2 System Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4. 3 Ethernet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.1 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.2 LAN Port Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3.3 LAN Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4. 4 Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.4.1 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.4.2 Console Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4. 5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4. 6 Rackmount Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Chapter 5: Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5. 1 Troubleshooting Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Chapter 6: Serial Port and User Equipment Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6. 1 Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6. 2 Custom HD-26 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6. 3 Connecting the User Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.3.1 Activating the User Equipment Connection . . . . . . . . . . . . . . . . 6-3
6. 4 WAN/User Port Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6. 5 Custom Serial Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
6.5.1 V.35/V.11 Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
6.5.2 TIA-232 (V.24) Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
6.5.3 X.21 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
6.5.4 X.21 EU Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5.5 TIA-449 (V.36) Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.5.6 TIA-530 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6. 6 Serial Port Connector and Custom HD-26 Cable Set Connectivity. . . . . . 6-8
Memotec Inc.
Appendix A: Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Memotec Standard Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Appendix B: Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Regulatory – Compliance and Agency Approval . . . . . . . . . . . . . . . . . . . . . . . . B-2
Compliance and Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
EU Directives 1999/5 and 2011/65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Intent of Use and Network Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
EN55022 and CISPR22 Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
FCC Part 15 Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
Industry Canada Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Notice d'Industrie Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Environmental Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Waste Electrical and Electronic Equipment – WEEE . . . . . . . . . . . . . . . . . B-8
China RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Safety Warnings and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Making Changes or Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Index-1
Memotec Inc.
Memotec Inc.
List of Figures
Front View of the SDM-8400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Distance from serial port to connected equipment . . . . . . . . . . . . . . . . . . . . . . . 2-3
Location of Rackmount Brackets on the SDM-8400 Chassis (AC power version shown) 3-
3
Power Cords for SDM-8400 UAC Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
DC power entry connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Wiring the DC connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Power Cords for SDM-8400 UAC Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Rear View of the SDM-8400 UAC (8-port version) . . . . . . . . . . . . . . . . . . . . . . . 4-2
Rear View of the SDM-8400 DC version (8-port version) . . . . . . . . . . . . . . . . . . . 4-2
DC Power Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Memotec Inc.
Memotec Inc.
List of Tables
System status LED states during normal power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Chapter references per Unit Item . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
ST LED states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
AL LED states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
RJ-45 pinout for Ethernet LAN port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
RJ-45 pinout for console port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Troubleshooting symptoms, problems, and solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Serial connector and NetPerformer custom HD-26 cable set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Memotec Inc.
1
Memotec 1-1
Preface
NetPerformer SDM-8400 Hardware Installation Guide
1-2 Memotec
1.1 Product Overview
The SDM-8400 is a data-only integrated access device that supports multiple serial ports
and Ethernet. It increases serial port capacity at an enterprise network node while
minimizing the number of NetPerformer units required.
It can be used for high density serial port applications, central site satellite solutions and
other applications requiring serial port extension. To maximize serial port availability,
Ethernet is the preferred interconnectivity between the SDM-8400 and other NetPerformer
products.
The SDM-8400 offers all data characteristics that are available for serial and Ethernet
interfaces in NetPerformer software version 10.2.1 or higher. It provides bandwidth
optimization for both LAN and serial data, QoS, data compression, routing and
multiplexing.
1.1.1 Sales Contacts
To order NetPerformer units, cables and optional parts, contact Memotec Inc. or your
NetPerformer distributor. To contact Memotec:
Memotec
7755 Henri Bourassa Blvd. West
Montreal, Quebec
Canada H4S 1P7
Telephone: +1 514.738.4781 during regular business hours, EST (GMT-05:00)
Fax: + (1) 514 738 4436
Web: http://www.memotec.com
Preface
Memotec 1-3
1.2 About this Document
This document, NetPerformer® SDM-8400 Hardware Installation Guide, provides the
following information about the SDM-8400:
Regulatory compliance information (“Compliance Information” on page B-1)
Unpacking instructions (“Unpacking” on page 2-1)
Hardware installation instructions (“Hardware Installation” on page 3-1)
Product description (“Product Description” on page 4-1)
Troubleshooting procedures (“Troubleshooting” on page 5-1)
Serial port specifications and user equipment connection (“Serial Port and User
Equipment Connection” on page 6-1)
Networking features (“Networking Features” on page 8-1)
For information on configuring NetPerformer, consult the NetPerformer Reference
Guides. See “NetPerformer Document Set” on page 1-4 for a list of other references.
NOTE: All NetPerformer documents are available on the NetPerformer Documenta-
tion CD, which is included with your product package.
CAUTION: All documents on the NetPerformer Documentation
CD, including this guide, must be opened with Adobe™
Acrobat Reader, which is provided on the CD. If you open a
NetPerformer document with an earlier version of Acrobat Reader,
some of the text will not appear in its intended format. This can
make the text difficult or impossible to read correctly, especially
from a printed copy.
1.2.1 Audience
This document is intended for use by NetPerformer system administrators as well as
technicians who are qualified to set up, configure and troubleshoot a NetPerformer
Enterprise Network.
Installation of NetPerformer hardware requires knowledge and proficiency in the
configuration, operation, maintenance and security of all enterprise network elements in
your application. You should also have a thorough understanding of telecommunications
and be familiar with the networking strategies and telephony solutions currently used by
your organization.
NetPerformer SDM-8400 Hardware Installation Guide
1-4 Memotec
1.2.2 Instructions to the Reader
Instructions to the reader include notes, cautions and warnings, which are distinguished
from the rest of the text by distinctive formatting and icons. Here is an example of each:
NOTE: A note may contain a reference, tip or other information related to the subject
at hand. The content of a note is intended to be helpful or of interest to the
reader.
CAUTION: A caution contains an instruction that the reader must
follow in order to prevent damage to equipment, network failure or
loss of data. The content of a caution must be read carefully and
explicitly obeyed.
WARNING: A warning contains an instruction that the reader must
follow in order to prevent electrical shock, death or serious injury
to personnel. The content of a warning must be read carefully
and explicitly obeyed.
1.2.3 Related Documents
NOTE: All of the documents listed here are available on the NetPerformer Compan-
ion CD, which is included with your product package.
1.2.4 NetPerformer Document Set
For further information on the NetPerformer, consult the following:
NetPerformer Reference Guides
Includes detailed information on NetPerformer features, menus, commands,
parameters and statistics displays.
NetPerformer Hardware Installation Guides
These documents describe the hardware specific to each NetPerformer product,
including base hardware features, installable options and complete installation
instructions.
NetPerformer Release Bulletins
Preface
Memotec 1-5
These documents summarize the system specifications, software fixes and
changes, and post-production documentation changes for a particular NetPer-
former release. They also include firmware upgrade warnings.
NetPerformer Network Design Guide
Offers valuable tips on how to design a NetPerformer application for maximum
efficiency, including an analysis of data and voice traffic throughput issues and
the impact of traffic flow. Provides examples of network setup and traffic meas-
urement using various NetPerformer products.
1.2.5 Training
We offer a variety of classes to reduce your learning curve and make your employees
more productive. Students learn how to tailor NetPerformer products to meet their specific
business requirements. Each course is developed and delivered by certified instructors
who have in-depth expertise and extensive technical training experience.
To learn more about our training services, email our education facilities at
1.2.6 Request for Comments
Our Technical Publications group welcomes your feedback. Please help us improve future
releases of this document by sending us your comments and suggestions. You can send
email to
NetPerformer SDM-8400 Hardware Installation Guide
1-6 Memotec
1.3 Changes to Console Operations
The following change to console operations was made in NetPerformer firmware version
V9.2.0 and higher. If you are familiar with earlier versions of the NetPerformer firmware,
this change should be taken into consideration before you configure or manage the
product.
The way you access the NetPerformer console now allows multiple user profiles.
However, the default
LOGIN is now ADMIN instead of ACT and the default PASSWORD
for this login remains
SETUP.
For full instructions on setting up user profiles, refer to the Quick Configuration module of
the NetPerformer Reference Guides.
1.3.1 Technical Support
Memotec Technical Support is designed to meet your full range of support needs. From
basic service to mission-critical support, we are committed to ensuring your success with
NetPerformer products. By employing state-of-the-art products and the latest technologies
available, we provide some of the fastest, most efficient service in the industry.
Our entire support organization is focused on complete customer satisfaction and
providing immediate solutions to your business needs.
You can contact Technical Support by calling or sending email to our helpdesk facilities:
Telephone: +1 514.738.4781 during regular business hours, EST (GMT-05:00)
Email:
Be prepared to provide the following information:
Your name
Company name
Your location
Telephone number
Product serial number (see next section)
Detailed problem description
Remote access to the troubled unit via Telnet or dial-up modem.
Preface
Memotec 1-7
1.3.2 Providing Product Number to Technical Support
You may be requested to provide the product serial number when communicating with
Technical Support.
Product Serial
Number
The product serial number is provided on the rear of the unit. See “Rear View of the
SDM-8400 UAC (8-port version)” on page 4-2 for location of label.
1.3.3 Checking the Contents of Your Product Package
CAUTION: As soon as you receive your SDM-8400, check the
carton and its contents for any sign of damage during shipment. If
there is any damage, contact the shipping agent immediately.
Before you begin SDM-8400 installation, verify the contents of the carton to ensure that
you have received all the units, accessories and cables that you ordered.
NOTE: A summary of product items appears on “Product Description” on page 4-1.
If any items are missing, or if you have any questions concerning your shipment, contact
Technical Support.
1.3.4 Returning an SDM-8400 Unit
If you need to return the SDM-8400 for any reason, you must ship it in the original
carton using adequate shock insulation material. Failure to do so may void the
equipment warranty. Consult the Warranty statements included with the product package.
Contact Technical Support for RMA requirements.
NetPerformer SDM-8400 Hardware Installation Guide
1-8 Memotec
2
Memotec 2-1
Unpacking
NetPerformer SDM-8400 Hardware Installation Guide
2-2 Memotec
2.1 About Unpacking the Unit
This chapter outlines preparatory steps that should be executed before you install and
configure the SDM-8400:
Selecting a location (“Selecting a Location” on page 2-2)
Preparing the site (“Preparing the Site” on page 2-4).
2.1.1 Selecting a Location
To ensure that the SDM-8400 functions properly, you should install the unit in an
appropriate location which satisfies certain criteria for size, connection distance and
ambient environment.
Caution: Unit must be installed in a restricted access location.
2.1.2 Size Requirements
Select a standard 19" (48 cm) equipment rack or a hard, flat surface that is:
- Capable of supporting the combined weight of the SDM-8400, its cabling and
attached equipment
- Near an easily accessible AC power socket or DC power supply.
To ensure proper ventilation of the SDM-8400, leave 2 inches (5 cm) of unob-
structed space around the unit chassis.
Ensure that a sufficient number of shelves, supports, racks and cabinets are avail-
able to safely house all equipment.
Figure 2-1: Front View of the SDM-8400
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Comtech EF Data Memotec NetPerformer SDM-8400 Hardware Installation Manual

Tipo
Hardware Installation Manual