Installation Manual
TYPE : 4-WAY CEILING CASSETTE
ENGLISH
FRANÇAIS
ESPAÑOL
960-911-07
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition-
er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
TIPS FOR SAVING ENERGY
TIPS FOR SAVING ENERGY
2
ENGLISH
3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation of all field wiring and components MUST conform with local building codes or, in
the absence of local codes, with the National Electrical Code 70 and the National Building
Construction and Safety Code or Canadian Electrical code and National Building Code of
Canada.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal-
function, property damage, personal injury and/or death.
Installation
• Always perform grounding. - Otherwise, it may cause electrical shock.
• Don’t use a power cord, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire
or electrical shock.
• For installation of the product, always contact the service center or a professional installation
agency. - Otherwise, it may cause a fire, electrical shock, explosion or injury.
• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
- If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not
attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Always install an air leakage breaker and a dedicated switching board. - No installation may cause a
fire and electrical shock.
• Do not keep or use flammable gases or combustibles near the air conditioner. - Otherwise, it may
cause a fire or the failure of product.
• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
- It may cause injury or an accident.
• Do not disassemble or repair the product randomly. - It will cause a fire or electrical shock.
• Do not install the product at a place that there is concern of falling down. - Otherwise, it may result
in personal injury.
• Use caution when unpacking and installing. - Sharp edges may cause injury.
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress
air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion. There is
the risk of death, injury, fire or explosion.
!
!
!
SAFETY PRECAUTIONS
ENGLISH
Operation
• Do not share the outlet with other appliances. - It will cause an electric shock or a fire due to heat
generation.
• Do not use the damaged power cord. - Otherwise, it may cause a fire or electrical shock.
• Do not modify or extend the power cord randomly. - Otherwise, it may cause a fire or electrical
shock.
• Take care so that the power cord may not be pulled during operation. - Otherwise, it may cause a
fire or electrical shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it. - Otherwise, it may cause electri-
cal shock or a fire.
• Keep the flames away. - Otherwise, it may cause a fire.
• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet
hands. - Otherwise, it may cause a fire or electrical shock.
• Do not use the power cord near the heating tools. - Otherwise, it may cause a fire and electrical
shock.
• Do not open the suction inlet of the indoor/outdoor unit during operation. - Otherwise, it may electri-
cal shock and failure.
• Do not allow water to run into electrical parts. - Otherwise, it may cause the failure of machine or
electrical shock.
• Hold the plug by the head when taking it out. - It may cause electric shock and damage.
• Never touch the metal parts of the unit when removing the filter. - They are sharp and may cause
injury.
• Do not step on the indoor/outdoor unit and do not put anything on it. - It may cause an injury through
dropping of the unit or falling down.
• Do not place a heavy object on the power cord. - Otherwise, it may cause a fire or electrical shock.
• When the product is submerged into water, always contact the service center. - Otherwise, it may
cause a fire or electrical shock.
• Take care so that children may not step on the outdoor unit. - Otherwise, children may be seriously
injured due to falling down.
CAUTION
Installation
• Install the drain hose to ensure that drain can be securely done. - Otherwise, it may cause water
leakage.
• Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to
the neighbors. - Otherwise, it may cause dispute with the neighbors.
• Always inspect gas leakage after the installation and repair of product. - Otherwise, it may cause the
failure of product.
• Keep level parallel in installing the product. - Otherwise, it may cause vibration or water leakage.
Operation
• Avoid excessive cooling and perform ventilation sometimes. - Otherwise, it may do harm to your
health.
• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. - The appearance of the air
conditioner may deteriorate, change color, or develop surface flaws.
• Do not use an appliance for special purposes such as preserving animals vegetables, precision
machine, or art articles. - Otherwise, it may damage your properties.
• Do not place obstacles around the flow inlet or outlet. - Otherwise, it may cause the failure of appli-
ance or an accident.
!
SAFETY PRECAUTIONS
4
ENGLISH
5
2 TIPS FOR SAVING
ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
6 INSTALLATION PLACES
7 THE INDOOR UNIT
INSTALLATION
8 Indoor Unit Drain Piping
9 Wiring Connection
11 INSTALLATION OF DEC-
ORATIVE PANEL(ACCES-
SORY)
13 TEST RUNNING
14 INSTALLATION
INSTRUCTIONS
14 Installer Setting - How to enter installer
setting mode
15 Installer Setting - Installer Setting
Code Table
TABLE OF CONTENTS
TABLE OF CONTENTS
ENGLISH
6
ENGLISH
INSTALLATION PLACES
INSTALLATION PLACES
- There should not be any heat source or steam near the unit.
- There should not be any obstacles to prevent the air circulation.
- A place where air circulation in the room will be good.
- A place where drainage can be easily obtained.
- A place where noise prevention is taken into consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
- The indoor unit must keep the maintenance space.
Ceiling
Ceiling Board
Ceiling Board
Floor
Unit:mm(inch)
300(11-
13
/
16
)
or more
Above 2500(98-
7
/
16
)
4000(157-
1
/
2
) or less
1000(39-
3
/8)
or more
500(19-
11
/16)
or more
500(19-
11
/16)
or more
300(11-
13
/
16
) or less
7
ENGLISH
THE INDOOR UNIT INSTALLATION
Level gauge
Ceiling
Ceiling board
TM/TN/TP Chassis
Unit:mm(inch)
875(34-7/16) (Ceiling opening)
787(30-15/16)
(Hanging bolt)
bolt)
684(26-15/16)(Hanging bolt)
671(26-7/16)
875(34-7/16) (Ceiling opening)
840(33-1/16)
Unit size
840(33-1/16)
Unit size
CAUTION
• This air-conditioner uses a drain pump.
Install the unit horizontally using a level
gauge.
• During the installation, care should be
taken not to damage electric wires.
!
THE INDOOR UNIT INSTALLATION
- Select and mark the position for fixing bolts
and piping hole.
- Decide the position for fixing bolts slightly
tilted to the drain direction after considering
the direction of drain hose.
- Drill the hole for anchor bolt on the wall.
- When using cardboard on the bottom of
packaging, use after separating installation
paper from bottom of the product packaging
using back of a knife as shown in the picture
(TM/TN/TP)
Included Paper Cardboard on the bottom
of packaging
NOTE
!
Avoid the following installation location.
1 Such places as restaurants and kitchen
where considerable amount of oil steam
and flour is generated. These may cause
heat exchange efficiency reduction, or
water drops, drain pump mal-function. In
these cases, take the following actions;
- Make sure that ventilation fan is enough
to cover all noxious gases from this
place.
- Ensure enough distance from the cooking
room to install the air conditioner in such
a place where it may not suck oily steam.
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling board
150mm
(5-7/8 inch)
Ceiling board
Ceiling
Keep the length of the bolt
from the bracket to 40mm(1-1/2 inch)
Open the ceiling board
along the outer edge of the
paper model
Air Conditioner body
Keep the length of 15~18mm(5/8~3/4 inch)
between the air conditioner bottom surface
and the ceiling surface
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Flat washer with insulation
attached (Install insulation to
be in contact with the indoor
unit hanger part.)
Drill the piping hole on the wall slightly tilted
to the outdoor side using a Ø 70 mm(2.8 inch)
hole-core drill.
The following parts is option.
Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10
Wall
Indoor
Outdoor
5~7mm
(0.20~0.29 inch)
CAUTION
Tighten the nut and bolt to prevent unit
falling.
!
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
Indoor Unit Drain Piping
- Drain piping must have down-slope (1/50 to
1/100): be sure not to provide up-and-down
slope to prevent reversal flow.
- During drain piping connection, be careful
not to exert extra force on the drain port on
the indoor unit.
- The outside diameter of the drain connection
on the indoor unit is 32 mm(1.3 inch).
- Be sure to execute heat insulation on the
drain piping.
- Install the drain raising pipes at a right
angle to the indoor unit and no more than
300 mm(11.8 inch) from the unit.
Piping material: Polyvinyl chloride pipe VP-
25 and pipe fittings
8
THE INDOOR UNIT INSTALLATION
ENGLISH
2 Avoid installng air conditioner in such
places where cooking oil or iron powder is
generated.
3 Avoid places where flammable gas is gen-
erated.
4
Avoid place where noxious gas is generated.
5
Avoid places near high frequency generators.
9
THE INDOOR UNIT INSTALLATION
800(31-1/2)
or less
1,000(39.4)~
1,500(59.1)
Clamp metal(attached) Drain hose(attached)
Drain raising pipe
300(11.8)
or less
Unit:mm(inch)
Heat insulation material: Polyethylene foam
with thickness more than 8mm(0.3inch).
Drain test
The air conditioner uses a drain pump to drain
water.
Use the following procedure to test the drain
pump operation:
- Connect the main drain pipe to the exterior
and leave it provisionally until the test comes
to an end.
- Feed water to the flexible drain hose and
check the piping for leakage.
- Be sure to check the drain pump for normal
operating and noise when electrical wiring is
complete.
- When the test is complete, connect the flexi-
ble drain hose to the drain port on the indoor
unit.
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
Main
drain pipe
Glue the joint
Drain
port
Drain hose connection
Use the clip (accessory)
1/50~1/100 slope
Hanger
distance
Hanger Bracket
Max 800mm
Flexible drain hose
Insulation
Metal
clamp
Max 300mm
1~15m
HEAT INSULATION
- Use the heat insulation material for the
refrigerant piping which has an excellent
heat-resistance (over 248°F(120°C)).
- Precautions in high humidity circumstance:
This air conditioner has been tested accord-
ing to the "KS Standard Conditions with Mist"
and confirmed that there is not any default.
However, if it is operated for a long time in
high humid atmosphere (dew point tempera-
ture: more than 74.4°F/23°C), water drops
are liable to fall. In this case, add heat insula-
tion material according to the following pro-
cedure:
- Heat insulation material to be prepared...
Adiabatic EPDM or NBR with thickness
10(0.4) to 20 mm(0.8 inch).
- Stick glass wool on all air conditioners that
are located in ceiling atmosphere.
Indoor
unit
Thermal insulator
(accessory)
Fastening band
(accessory)
Refrigerant
piping
Wiring Connection
- Open the control box cover and connect the
Remote controller cord and Indoor power
wires.
- Remove the control box cover for electrical
connection between the indoor and outdoor
unit. (Remove screws )
- Use the cord clamper to fix the cord.
CAUTION
The supplied flexible drain hose should not
be curved, neither screwed. The curved or
screwed hose may cause a leakage of water.
!
ENGLISH
10
ENGLISH
THE INDOOR UNIT INSTALLATION
Precautions when laying power
wiring
Use round pressure terminals for connections
to the power terminal block.
When none are available, follow the instruc-
tions below.
- Do not connect wiring of different thickness-
es to the power terminal block. (Slack in the
power wiring may cause abnormal heat.)
- When connecting wiring which is the same
thickness, do as shown in the figure below.
CAUTION
The connecting cable connected to the
indoor and outdoor unit should be com-
plied with the following specifications
(This equipment shall be provided with a
cord set complying with the national regu-
lation).
!
CAUTION
The Power cord connected to the unit
should be selected according to the fol-
lowing specifications.
!
If the supply cord is damaged, it must be
replaced by a special cord or assembly
available from the manufacturer of its
service agent.
Power wirer
Round pressure terminal
Connect same thickness
wiring to both sides.
It is forbidden to
connect two to one
side.
It is forbidden to
connect wiring of
different thicknesses.
- For wiring, use the designated power wire
and connect firmly, then secure to prevent
outside pressure being exerted on the termi-
nal block.
- Use an appropriate screwdriver for tightening
the terinal screws. A screwdriver with a
small head will strip the head and make prop-
er tighterning impossible.
- Over-tightening the terminal screws may
break them.
Lock nut
Conduit
mounting
plate
Conduit
11
ENGLISH
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
6 Open two screws of control panel cover.
Screw
Link
Link
Filter
guide
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
The decorative panel has its installation
direction.
Before installing the decorative panel,
always remove the paper template.
1 Remove the packing and take out air inlet
grille from front panel.
Front
grille
2 Remove the Corner covers of the panel.
Coner
cover
3 Fit the panel on the unit by inserting hooks
as shown in picture.
5 Fit the corner covers.
4 Insert two screws on diagonal corners of
panel. Do not tighten the bolts completely.
(The fixing screws are included in the
indoor unit box.)
Check the alignment of panel with the ceil-
ing. Height can be adjusted using hanging
bolts as shown in picture. Insert the other
two screws and tighten all screws com-
pletely.
Hook
clip
Hook
Link
Link
Filter
guide
12
ENGLISH
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
7 Connect one display connector and two
vane control connectors of front panel to
indoor unit PCB.
The position marking on PCB is as:
Display connector : CN-DISPLAY
Vane control connector: CN-VANE 1,2
8 Close the cover for control box.
9 Fit the link on the panel as shown in pic-
ture. (The link is included in the front panel
unit box.) (TM/TN/TP)
10 Attach the other side of link on the filter
guide of inlet grille. Install the air inlet
grille and filter on the panel. (TM/TN/TP)
11 Install the air inlet grille and Filter on the
panel.
CN-VANE 1,2
CN-DISPLAY
Link
Link
Filter
guide
Link
Link
Filter
guide
LinLink
Link
Filter
guide
Link
Link
Lin
Link
Filte
Filter
guid
guide
Link
Filter
guide
Link
Link
Filter
guide
Air conditioner
unit
Decorative panel
Fit the insulator (this part) and
be careful for cool air leakage
Good example
Ceiling
board
Ceiling
board
Decorative
panel
Air
Cool air leakage
(no good)
Bad example
Air conditioner unit
CAUTION
Install certainly the decorative panel.
Cool air leakage causes sweating.
Water drops fall.
!
13
ENGLISH
TEST RUNNING
TEST RUNNING
PRECAUTIONS IN TEST RUN
- The initial power supply must provide at least
90% of the rated voltage.
Otherwise, the air conditioner should not be
operated.
Connection of power supply
- Connect the power supply cord to the inde-
pendent power supply.
Circuit breaker is required.
- Operate the unit for 15 minutes or more.
CHECK THE FOLLOWING ITEMS WHEN
INSTALLATION IS COMPLETED
- After completing work, be sure to measure
and record trial run properties, and store
measured data, etc.
- Measuring items are room temperature, out-
side temperature, suction temperature, blow
out temperature, wind velocity, wind vol-
ume, voltage, current, presence of abnormal
vibration and noise, operating pressure, pip-
ing temperature, compressive pressure.
- As to the structure and appearance, check
following items.
* Is the circulation of air adequate?
* Is the draining smooth?
* Is the heat insulation complete
(refrigerant and drain piping)?
* Is there any leakage of refrigerant?
* Is the remote controller switch operated?
* Is there any faulty wiring?
* Are not terminal screws loosened?
(Torque for screw size)
M4…..11 lbf.in / 118 N.cm(12 kgf.cm)
M5…..18 lbf.in / 196 N.cm(20 kgf.cm)
M6…..22 lbf.in / 245 N.cm(25 kgf.cm)
M8…..53 lbf.in / 588 N.cm(60 kgf.cm)
- To cancel the test run, press any button.
CAUTION
• For test run, carry out the cooling opera-
tion firstly even during heating season.
If heating operation is carried out firstly,
it leads to the trouble of compressor.
Then attention must be paid.
• Carry out the test run more than 5 min-
utes without fail.
(Test run will be cancelled 18 minutes
later automatically)
!
Evaluation of the performance
- Measure the temperature of the intake and
discharge air.
- Ensure the difference between the intake
temperature and the discharge one is more
than 14.4°F(8°C) (Cooling) or reversely
(Heating).
Thermometer
14
ENGLISH
Installer Setting - How to enter installer setting mode
INSTALLATION INSTRUCTIONS
1 With the SURGE button pressed, press the
RESET button.
2 By using the TEMPERATURE SETTING
button, set function code and setting
value. (Please refer the Installer Setting
Code Table.)
3 Press the ON/OFF button toward the
indoor unit 1 time.
4 Reset the remote controller to use the
general operation mode.
CAUTION
Installer setting mode is to set the detail function of the remote controller.
If the installer setting mode is not set correctly, it can cause problems to the product, user
injury or property damage. This must be set by an certificated installer, and any installation
or change that is carried out by a non-certificated person should be responsible for the
results. In this case, free service cannot be provided.
!
Refer to the Installer Setting Code Table
on the next page.
15
ENGLISH
Mode Override
This Function is only for Non-Auto Changeover H/P model.
Ceiling Height Selection
Indoor unit connected to wired remote controller operate as wired remote controller setting.
Group Control
This function is only for group control. Please don’t set this function in case of non-group
control.
After setting Group Control of the product, turn off the power then turn it back on after 1
minute.
Installer Setting - Installer Setting Code Table
No. Function Function Code Setting Value Remote Controller LCD
0 Mode Override
0
0 : Set to Master
1 : Set to Slave
1
Ceiling Height
Selection
1
1 : Standard
2 : Low
3 : High
4 : Super High
2 Group Control
2
0 : Set to Master
1 : Set to Slave
2 : Check Master/Slave
16
ENGLISH
Manuel d'installation
TYPE : CASSETTE 4 VOIESTYPE CASSETTE
FRANÇAIS
ASTUCES POUR ECONOMISER L’ENERGIE
2
FRANÇAIS
ASTUCES POUR ECONOMISER L’ENERGIE
Nous vous donnons ici quelques astuces qui vous permettront de minimiser la consommation
d’énergie lorsque vous utilisez le climatiseur. Vous pouvez utiliser un climatiseur de manière plus
efficace en vous référant aux instructions ci-dessous.
• Evitez un refroidissement excessif des unités intérieures. Une telle application pourrait repré-
senter un danger pour votre santé et entraîner une plus grande consommation de courant.
• Evitez d'exposer le climatiseur aux rayons solaires à l’aide des rideaux ou des persiennes lors-
qu’il est en marche.
• Maintenez les portes et les fenêtres complètement fermées lorsque vous utilisez le climati-
seur.
• Ajustez le sens du débit d’air verticalement ou horizontalement pour permettre la circulation
de l’air intérieur.
• Accélérez le ventilateur pour refroidir ou réchauffer rapidement l’air intérieur en peu de temps.
• Ouvrez régulièrement des fenêtres pour des besoins d’aération étant donné que la qualité de
l'air intérieur peut se détériorer si vous utilisez le climatiseur pendant plusieurs heures.
• Ouvrez régulièrement des fenêtres pour des besoins d’aération étant donné que la qualité de
l'air intérieur peut se détériorer si vous utilisez le climatiseur pendant plusieurs heures.
Pour vos archives
Agrafez votre reçu sur cette page dans le cas où vous en avez besoin pour prouver la date d’achat ou
pour des besoins de garantie. Ecrivez le numéro du modèle et le numéro de série ici:
Numéro du modèle:
Numéro de série:
Ces numéros sont disponibles sur l’étiquette de chaque côté du climatiseur.
Nom du distributeur:
Date d’achat:
3
CONSIGNES DE SECURITE IMPORTANTES
LISEZ ENTIEREMENT LES INSTRUCTIONS AVANT D’UTILISER LAPPAREIL.
Respectez toujours les consignes suivantes pour éviter des situations dangereuses et garantir une
performance optimale de votre produit.
ATTENTION
Le non respect de ces consignes peut être fatal ou provoquer des blessures graves.
AVERTISSEMENT
Le non respect de ces consignes peut provoquer des blessures légères ou endommager le produit.
ATTENTION
• Les travaux d’installation ou de dépannage effectués par des personnes non qualifiées peuvent vous exposer
aux risques en même temps que les autres personnes.
• L’installation d’un câblage et des composantes sur site DOIVENT être conformes aux codes de construction lo-
caux ou, en l'absence de codes locaux, au Code National d’Électricité 70 et au Code National de Sécurité et de
Construction de Bâtiment ou le code canadien de l’électricité et le Code national de construction du Canada.
• Les informations contenues dans ce manuel sont destinées à un technicien de maintenance qualifié qui maî-
trise les consignes de sécurité et dispose d’outils et d’instruments de test appropriés.
• Le fait de ne pas lire attentivement et de ne pas respecter les instructions de ce manuel peut provoquer un
dysfonctionnement de l’équipement, des dégâts matériels, des blessures individuelles et/ou la mort.
Installation
• Mettez toujours à terre le produit. - Autrement, vous risquez de provoquer un choc électrique.
• N'utilisez pas un cordon d’alimentation, une fiche d’alimentation ou une prise de courant endommagés.
- Autrement, vous risquez de causer un incendie ou un choc électrique.
• Pour l'installation du produit, contactez toujours le centre après-vente ou un service d’installation profession-
nel. - Autrement, vous risquez de provoquer un incendie, un choc électrique, une explosion ou des blessures.
• Fixez correctement le couvercle de protection des pièces électriques à l’unité intérieure et le panneau de ser-
vice à l’unité extérieure. - Si le couvercle de protection des pièces électriques de l’unité intérieure et le pan-
neau de service de l’unité extérieure ne sont pas bien fixés, cela peut provoquer un incendie ou un choc
électrique dus à la poussière, à l’eau, etc.
• Installez toujours un interrupteur pour fuites d’air et un tableau électrique spécialisé. - Ne pas le faire peut pro-
voquer un incendie ou un choc électrique.
• Ne rangez ni n’utilisez de gaz inflammable ni de combustibles près du climatiseur. - Autrement, vous risquez
de provoquer un incendie ou le mauvais fonctionnement de l’appareil.
• Assurez-vous que le cadre d’installation de l’unité extérieure ne soit pas endommagé à cause d’une utilisation
prolongée. - Cela peut provoquer des blessures ou un accident.
• Ne démontez ni ne réparez le produit en n’importe quel point. - Cela peut provoquer un incendie ou un choc
électrique.
• N'installez pas le produit dans un endroit d’où il puisse tomber. - Autrement, vous risquez de blesser quel-
qu’un.
• Soyez prudent pendant le déballage et l’installation. - Les bords aiguisés peuvent provoquer des blessures.
• Utilisez une pompe à vide ou un gaz Inerte (azote) lorsque vous faites des essais de fuite ou la
purge d’air. Ne compressez pas l'air ou l'oxygène et n'utilisez pas de gaz inflammable. Cela pour-
rait provoquer un incendie ou une explosion. Risque de décès, de blessure, d'incendie ou d'explo-
sion.
!
!
!
CONSIGNES DE SECURITE IMPORTANTES
FRANÇAIS
Fonctionnement
• Ne partagez pas la prise avec d’autres appareils. - Cela peut provoquer un choc électrique ou un incendie à cause de la
génération de chaleur.
• N'utilisez pas un cordon d’alimentation endommagé. - Vous risquez de provoquer un incendie ou un choc électrique.
• Ne modifiez ni ne rallongez le cordon d’alimentation en n’importe quel point. - Autrement, vous risquez de provoquer
un incendie ou un choc électrique.
• Veillez à ce que le cordon d’alimentation ne soit pas tiré en cours de fonctionnement. - Autrement, vous risquez de
provoquer un incendie ou un choc électrique.
• Débranchez l’unité si vous constatez la présence de bruits étranges, d’odeurs ou de fumée provenant de l’appareil. -
Autrement, vous risquez de provoquer un incendie ou un choc électrique.
• Évitez le contact avec des flammes. - Autrement, vous risquez de provoquer un incendie.
• A l’occasion, débranchez la fiche d’alimentation, en la prenant par la tête, et ne la touchez pas avec les mains
mouillées. - Autrement, vous risquez de provoquer un incendie ou un choc électrique.
• N`utilisez pas le cordon d’alimentation près des dispositifs de chauffage. - Autrement, vous risquez de provoquer un
incendie ou un choc électrique.
• N’ouvrez pas l’ouverture d’aspiration de l’unité intérieure/extérieure en cours de fonctionnement. - Autrement, vous
risquez de provoquer un choc électrique ou un mauvais fonctionnement.
• Ne permettez pas que de l’eau entre en contact avec les pièces électriques. - Autrement, vous risquez de provoquer
le mauvais fonctionnement de l’appareil ou un choc électrique.
• Prenez la fiche d’alimentation par la tête lorsque vous la débranchez. - Cela peut provoquer un choc électrique ou des
dommages.
• Ne touchez jamais les pièces métalliques de l’unité lorsque vous retirez le filtre. - Elles sont aiguisées et peuvent pro-
voquer des blessures.
• Ne montez sur l’appareil ni n’y placez aucun objet. - Autrement, vous risquez de vous blesser en tombant de l’appareil.
• Ne placez pas d’objet lourd sur le cordon d’alimentation. - Autrement, vous risquez de provoquer un incendie ou un
choc électrique.
• Contactez le service après-vente si le produit est submergé dans l’eau. - Autrement, vous risquez de causer un incen-
die ou un choc électrique.
• Veillez à ce que les enfants ne montent pas sur l’unité extérieure. - Autrement, ils risquent d’être sérieusement bles-
sés en tombant.
AVERTISSEMENT
Installation
• Installez le raccord de drainage de manière à assurer un drainage convenable. - Autrement, vous risquez de causer une
fuite d'eau.
• Installez le produit de sorte que vos voisins ne soient pas dérangés par le bruit ou par le vent chaud venant de l'unité
extérieure. - Autrement, vous risquez de susciter des querelles avec les voisins.
• Après l’installation ou la réparation du produit, veillez toujours à vérifier qu’il n’y ait pas de fuite de gaz.
- Autrement, vous risquez de causer le mauvais fonctionnement de l'appareil.
• Maintenez le niveau lors de l’installation du produit. - Autrement, vous risquez de provoquer des vibrations ou une
fuite d'eau.
Fonctionnement
• Évitez le refroidissement excessif et aérez parfois. - Autrement, vous risquez de nuire à votre santé.
• Utilisez un tissu doux pour nettoyer l’appareil. N'employez ni de cire, ni de diluant ni de détergent fort.
- Autrement, vous risquez de détériorer l’aspect de l’appareil, changer sa couleur ou provoquer des défauts sur sa sur-
face.
• N'utilisez pas le produit à des buts particuliers, tels que la préservation d’animaux, de plantes, de dispositifs de préci-
sion ou d’objets d'art, etc. - Autrement, vous risquez d’endommager vos biens.
Ne placez pas d'obstacles autour de l'entrée ou de la sortie du flux d’air. - Autrement, vous risquez de provoquer le
mauvais fonctionnement de l’appareil ou un accident.
!
CONSIGNES DE SECURITE IMPORTANTES
4
FRANÇAIS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195

Friedrich MC24Y3J Istruzioni per l'uso

Categoria
Condizionatori d'aria mobili
Tipo
Istruzioni per l'uso
Questo manuale è adatto anche per