WARRIOR LDG12S Manuale utente

Categoria
Generatori di corrente
Tipo
Manuale utente

Questo manuale è adatto anche per

Operating Manual
Diesel Generators
REV 20221117 Warrior Power Equipment, Unit 17-18, Bradley Hall Trading Estate,Bradley Lane, Standish, Wigan, WN6 0XQ, United Kingdom
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating
the product. Failure to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication but are subject to change
without notice.
FOR MODELS:
LDG12S, LDG12S3
ENGLISH
DEUTSCH
FRAAIS
ITALIANO
ESPAÑOL
POLSKI
SVENSKA
WPE DIESEL GENERATORS INTRODUCTION
2
INTRODUCTION
Thank you for purchasing our product.
This product is guaranteed against faulty manufacture
for a period of 24 months from the date of purchase.
Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have
been abused or tampered with in any way, or not used
for the purpose for which it was intended. Faulty goods
should not be returned to the place of purchase,
the generator should be returned to the supplier of
the product. No product can be returned without
prior permission. This guarantee does not affect your
statutory rights.
When contacting WPE about parts and/or service,
you will need to supply the complete model and serial
numbers of your product. Transcribe the information
found on your product’s nameplate label to the table
below
WPE TECHNICAL SUPPORT TEAM
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
IMPORTANT
1. Children should be kept at a safe distance from the
generator and NEVER allowed to operate it.
2. Your new generator needs a break in period of
approx. 10 hours with NO more 75% maximum load
being applied. After first 10 hours the oil MUST
be changed, recommended oil 10W30 low or Non
Synthetic.
3. Don’t touch the engine or muffler while generator
is in operation. Please pay attention to warning and
caution stickers on the generator.
4. Electrical equipment (including cable and plug
connecting component) should be in good condition
before starting and inspected prior to use.
5. If replacing circuit breaker it must be equivalent or
better in specification of the one to be removed.
6. Due to high mechanical stress, only rubber sheathed
cables are recommended to be used.
7. When using extension cords or mobile distribution
cabinet, the wire with 1.5mm2 cross section should
not be longer than 50 metres; and for 2.5mm2 cross
section wire should not be longer than 100 metres in
length.
8. With manual starting, always use decompression
lever. (ONLY on Open Frame Type)
9. On standard working ambient conditions (minus
5 to 40 degree Centigrade), the generator can be
operated at normal running loads. If the working
condition of circumstance are not normal either
too high or too low, the generator should be run at
a lower output of no more than 75% maximum load.
When temperature, altitude and humidity is higher
than standard working condition, the generator
MUST reduce the output load to no more than 75%
maximum load.
10. Before any inspection or maintenance of the
generator, the engine must be stopped and allowed
to cool for a minimum 30 minutes. Check and
maintain the generator according to the period table
and schedule sheet in the manual.
11. Except the daily maintenance or cleaning, any
inspection or readjustment should be conducted
by authorized professional person and source the
requested original components by them from the
supplier. (Contact your local dealers).
12. Your newly overhauled machine must endure a
breaking-in period of at least 10 hours, the output
should not exceed 75% of the maximum load.
WPE DIESEL GENERATORS FEATURES
3
EN
FEATURES
WPE Diesel generator possesses the following features:
This series diesel generator adopts super-light type, air
cooled, 4-stoke direct injection diesel engine and has two
starting options:
1. Recoil start
2. Electric start.
They are equipped with large capacity fuel tank, circuit
protector, A.C and sometimes D.C voltage outputs, low oil
pressure alarm and automatic stopping device.
The diesel generator serves as an UPS stand-by power
supply in many different applications including open
working site, construction and field army. Emergency
power of poultry farm, fishery, forestry, garden, hotel,
shop, and office.
This operation manual tells you how to operate and
service your new diesel generator. Please read it before
using the diesel generator to ensure proper handing
and operation. Following these instructions carefully will
keep your diesel generator in the best working condition,
allowing to prolong the life of your diesel generator.
If you have any questions concerning your new product
or any of the information given in this manual, please
contact service@bpeholdings.co.uk.
PARAMETERS
The generators can generate specified power when used
in the following conditions:
Altitude: < 1000m
Ambient Temperature: 5 to 40°C
Relative humidity: <90%
WARNING
Exhaust/mufflers and gases are very hot to
touch. DO NOT add or install any exhaust/muffler
extensions, by doing so you will void any warranty
offered.
Preventing burns
NEVER touch or handle exhaust/muffler, engine when
generator is running or hot, always leave approx 30
minutes for the exhaust/muffler & engine to cool before
handling.
IMPORTANT
Please read and understand this operation manual to
insure safe operation, and pay high attention to the
following main points of operation otherwise it may
cause personal injury and damage to equipment.
Preventing fires
The fuel of diesel engine is light diesel fuel , so gasoline,
kerosene etc. must NEVER be used.
Wipe away all fuel spills with a clean cloth. Keep
gasoline, kerosene, matches and other explosives
and inflammable substance away from the generator,
because the temperature around the exhaust muffler is
very high during operation. To prevent fire hazards and
to provide adequate ventilation, keep the generator at
least 1.5 meter away from buildings, structures and other
equipment during operation.
Operate the generator on a flat level surface, there may
be fuel spillage or poor operation if the generator is tilted.
Preventing exhaust gas inhalation
Exhaust gas contains poisonous carbon monoxide.
Always use the generator in outdoor locations minimum
1.5m anyway from window, doors or opening.
Generators MUST never be used indoors, in garages,
cabins, out building, sheds or any confined spaces
including vehicles and vehicle compartments.
Electric shocks, short circuits
In order to avoid electric shocks or short circuit, do not
touch the generator, when either it or your hands are wet.
This generator is not waterproof , so it should NEVER be
used in a place exposed to rain, snow or water sprays.
The generator should be ground to prevent electric
shocks. Please connect a length of heavy wire between
the generators ground terminal and an external ground
device, ground rod or stake - minimum 200mm deep.
Do not connect any equipment to the generator before
you start it.
WARNING
Most appliance motors require more than their rated
wattage for start up. Do not exceeded the current
limit specified for any one socket.
Charging the battery
Battery electrolyte contains sulphuric acid. Protect
your eyes, skin and clothing. In case of contact, flush
thoroughly with water and get prompt attention,
especially if your eyes are affected.
Batteries generate hydrogen gas, which can flames or
sparks near a battery, especially during charging.
Charge the battery in a fully ventilated area.
WPE DIESEL GENERATORS PREPARATION BEFORE START
4
WARNING
Know how to stop the generator quickly, and
understand how to operate all of the controls. Never
permit anyone to operate the generator without
proper instruction.
Always wear a helmet, safety shoes and proper
clothing. Keep pets and children away from the
generator when it is in operation.
PREPARATION BEFORE START
Selection and handling of fuel
Only light diesel fuel can be used.
The fuel must be filtered .
Fuel should be free of water or dust because these
can contaminate the fuel injection system.
Do not overfill the tank beyond the top of the red plug
inside the fuel tank filter, use fuel gauge on top of tank.
Do not smoke and allow sparks in the area where the
engine is refueled or where gasoline is stored.
Do not spill fuel when refueling, make sure the filter
cap is securely closed.
Selection and handling of oil
Check oil level before every operation.
Set the generator on a level surface.
Open the door to find the oil dip stick.
To check the oil level, simply dip the dipstick into the
pan. Do not screw in the dipstick when checking.
NOTICE
Nothing effects the performance and durability of
the generator more than the oil you use. If inferior oil
is used or if your engine oil is not changed regularly,
the risk of piston seizure, piston ring sticking and
accelerated wear of the cylinder liner, bearings and
other moving components increase significantly.
Make sure to check the oil level and to refill with oil to
the specified level before starting the generator, even
though it is equipped with a low oil pressure warning
system.
If your generator doesn’t start by the 5th attempted or
starts and cuts out, your oil level is to low and needs to
topped up.
NOTICE
Oil should be changed after the first 20 hours (or 1
month) of use and then every 3 months or 100 hours
of use.
Be sure to drain the oil while the engine is warm but
not hot . It is difficult to drain the oil completely after
cooling.
WARNING
NEVER add or attempt to change oil into the
generator while the engine is running.
Check air filter
Loosen the wing nut, detach the cover of air cleaner
and remove the element. Do not wash air cleaner
element with detergent . Use water or petrol (MUST
allow to dry before replacing).
The air cleaner element must be changed when the
output of engine decreases or the color of exhaust is
abnormal.
Never run the generator without the air cleaner
element. This may cause rapid engine wear.
Reattach the cover of air cleaner and tighten the wing
nut.
Ensure no load on generator
Turn off the main circuit breaker and any other loads.
Be sure to turn off the main circuit breaker before
starting the generator. If the switch is not on the “OFF“
position, sudden application of load could be very
dangerous, when the diesel engine is started.
The generator should be earthed to prevent electric
shocks. (Recommended).
WPE DIESEL GENERATORS OPERATION
5
EN
Handling of dual voltage type generator
Operation of change over switch: The AC circuit
breaker on the control panel must be set to ‘OFF’
position before running the machine. After starting
the generator, allow the speed to reach rated RPM
and then turn the AC circuit breaker to the “ON
position, so that the receptical sockets can be used
for operating equipment.
NEVER try to switch between voltages when the AC
circuit breaker is ON and equipment plugged IN.
Set the main AC circuit breaker to the “OFF” position
when using the 12v DC power supply.
Check for Airlock
WARNING
The FUEL and engine OIL are drained off by factory
prior to transportation. Generators are dry for
storage.
Check for airlock in fuel pipeline, and find whether
there is air mixed into the pipeline, if yes, drain away
the air from the pipeline before refuel and start the
diesel engine.
Fuel filter should be minimum 75% full, if not then air
may be present in system.
The method to remove is, loosen the 17mm gland
nut connection between injecting pump and high
pressure brass pipeline, put run lever to “RUN
position and turn over the engine until fuel starts to jet
out.
Replace and re-tighten 17mm gland and repeat the
process if engine still does not start.
OPERATION
Preheater Feature
This generator is equipped with a Preheater button
function for cold temperatures less than 0°C, this feature
is designed to warm the engine and oil up first using
the 12v DC power provided from the battery prior to the
engine being cranked over.
If the outside temperature is less than 0°C it is
recommended to use the preheater function button first
before starting the engine.
1. Turn the Ignition key to the ‘ON’ position
2. Press and hold the preheater button for minimum 5
secs until the solid red illumination light appears
3. Release the button and start generator normally
using key or remote (Wireless remote models Only)
If the generator fails to start repeat steps 1-3 maximum 3
times only, if the generator doesnt start after 3 attempts
contact your local service agent.
Low oil warning system
Device works to stop the engine automatically when
the oil pressure falls below the regulatory level and
will prevent engine seizure when the engine oil is
running low or engine pressure is lost.
The oil temperature will rise high if the engine is
operated with insufficient engine oil. On the other
hand, too much oil is dangerous because the oil may
combust and cause a sudden and excessive rise in
engine rpm, so before operating the machine each
day be sure to check the oil and fill oil to the specified
level if necessary.
Low Oil Warning Light
Your generator is equipped with a low oil warning light.
If the event the light is illuminated ‘Solid Red’ then your
generator requires oil to be added immediately.
1. Stop running application immediately and turn off
engine and allow to cool for approx 10-15mins.
2. Remove oil level dipstick and clean.
3. Add oil, using an oil funnel (not provided) and check
using oil level dipstick (as good general rule oil is full
when it can been visually seen on the middle/upper
threads of the port). If using the oil dipstick NEVER
screw in oil level dipstick to take a reading simply rest
against top of the port and view reading.
4. Screw back in oil level dipstick
5. Run the engine for 10mins without any load allowing
the oil to fully circulate.
6. Check oil level again
Failure to add the recommended oil capacity may result
in increased engine wear and(or) damage to the engine.
Opening the cabinet door and cover.
Opening the cabinet door and raise the door and check
daily.
7. Turn the handle anticlockwise to open cabinet door.
8. Turn the handle clockwise to lock cabinet door.
Break-in operation
While your generator is still new, application of heavy
loads may shorten the life of the engine. Follow the break-
in procedures during the first 20 hours.
1. Avoid applying any heavy load during the break-in
period.
WPE DIESEL GENERATORS OPERATION
6
2. Change engine oil regularly. Change the engine oil
every 20 hours or one month after the initial use, and
every 3 months or 100 hours thereafter.
Starting the generator
Electric Start
1. Turn the AC circuit breaker switch to “OFF” position,
Make sure the generator is grounded recommended
200mm earth rod.
2. Turn the starting key to the “Sart” position. (for no
more than 8 seconds).
3. Remove your hand from the key as soon as the
engine starts and let the key return automatically to
the ‘ON’ initial position.
WARNING
If the starting motor soesnt start, please wait at least
30 seconds before attempting to start again.
WARNING
Please Note: If the starting motor is run for too long it
will flatten the battery.
Battery
Check the level of the fluid in the battery once every
month. When the level drops to the lower upper mark
replenish with distilled water up to the upper mark.
If battery fluid is low, the engine may fail to start because
too little electricity is reaching the starter motor. Always
keep the fluid level between the upper level and lower
level.
If too much battery fluid is applied, the fluid may spill and
corrode the surrounding parts. DO NOT over fill.
Batteries are only covered by a 1 year warranty from
original date of purchase.
Operating your generator
1. Warm up the engine without load for about 10
minutes.
2. Our generator is equipped with low oil warning
system. The engine will stop automatically in case
of low oil pressure or a lubrication oil shortage. The
engine will stop immediately if restarted without a
lubrication oil refill. Check the oil level and refill if
necessary.
3. Do not loosen or readjust either the engine speed
limiting bolt or fuel injection limiting bolt (They have
been factory set) otherwise performance and fuel
economy will be affected.
Check during operation
1. Any abnormal sound or vibration?
2. The engine misfiring or running rough.
3. What about the color of the exhaust gas? (Is it black
or too white?)
If you notice any of the above phenomenon, stop the
engine and consult your nearest dealer or contact
technical support on [email protected].
AC Operation
1. Start the engine and make sure the ‘GREEN’ pilot
lamp turns on. If it does not, the filament may be
burnt out.
2. The speed of generator must reach rated speed
(lever at top).
3. Generator can load when the indicator of voltmeter
shows at 240±10% (50Hz) on the panel of control box.
4. Plug in the appliance.
WARNING
Do not start two or more machines simultaneously.
Start them one by one. Do not use floodlights
together with other machines.
5. Be sure that all pieces of equipment are in good
working condition before connecting them to the
generator.
6. If an appliance or piece of equipment begins to
operate abnormally, becomes sluggish, or stops
suddenly, turn off the generator immediately. Then
disconnect the appliance and examine it for signs of
malfunction.
7. If overloading of the circuit trips the AC circuit
protector, reduce the electrical load on the circuit,
and wait a few minutes before resuming operation .
8. If the LCD display voltmeter is too low or too high,
stop the machine and examine it for cause of fault.
Voltage Selector Switch
You generator is supplied with a new 3 way voltage
selector switch. (Single Phase UK Models Only)
WPE DIESEL GENERATORS MAINTENANCE
7
EN
1. Turn the voltage selector switch to position ‘0’ when
generator is not in use or being starting.
2. Push the circuit breaker to ‘OFF’ position.
3. Start up the generator and allow engine to stabilize
for approx 5 minutes..
4. Plug in your electrical equipment and turn ‘ON’ the
piece of equipment.
5. Turn the voltage selector switch to either position 1 or
2 for the required voltage. Read the voltage display
for the correct voltage output.
6. Push the circuit breaker to the ‘ON’ position.
7. Check power to the equipment by operating it.
8. To change selected voltage, first turn ‘OFF’
equipment and disconnect the plug from the
generator socket.
9. Choose new equipment and voltage repeat steps 1-7
10. Never switch between position 1 or 2 whilst
equipment is plugged in, always disconnect
equipment before changing voltage.
11. When not in use always turn the switch to ‘0’ and
disconnect equipment or push circuit breaker to
‘OFF’ position.
Stopping the generator
1. DO NOT stop the generator when it is under load. It
will damage the generator or equipment.
2. Turn off the AC circuit breaker.
3. Turn the ignition key anticlockwise to “OFF” position .
MAINTENANCE
Periodic check and maintenance are very important for
keeping the engine in good condition. Please read the
detailed description of operating manual for each part.
Shut off the engine before performing any maintenance.
If the engine must run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
After the engine has been used, clean it immediately with
a cloth to prevent corrosion and remove sediment.
DAILY
Check oil level
Check and replenish fuel
Check for oil leakage
Battery Liquid
Air Cleaner
Check and tighten and engine parts if loose
FIRST 20 HOURS
Change oil
Clean Oil Filter
EVERY 100 HOURS OR 3 MONTHS
Change oil
Change oil filter
Change fuel filter
Clean Air Filter
Check/Adjust valve clearance*
EVERY 2 YEARS
Replace fuel line*
* Special tools or skills are required - please do not
attempt yourself - consult Technical Support on
service@bpeholdings.co.uk. (charges may apply)
Changing engine oil (Every 100Hrs)
Refill with the recommended oil 10W30 Non or part
synthetic.
1. Open left door, use the fork to release the drain plug
(don’t take out screw), put the oil guide groove under
the drain plug, let its outlet connect with oil container,
then completely remove the oil drain plug.
2. Begin to release out the oil and when the oil sump is
empty, if necessary, use the diesel to clean the inside
of the cylinder block.
3. Replace the drain plug.
4. Move the plastic rounded lid on the top of generator,
unscrew the cylinder head oil cap, fill the oil until
reach the oil gauge max limited in the end screw back
the cylinder head stud.
Cleaning the air filter (Every 100 hours)
Move the upper plate and back cover of the generator,
you will see the air cleaner. release the clip, unload the
WPE DIESEL GENERATORS STORAGE
8
lower half part of the air cleaner, and take out the filter
element in the middle; wash the filter element with diesel
fuel and put it back in the air cleaner after it is dry.
Checking and replenishing battery fluid and charging
and battery (Monthly)
This diesel engine uses a 12v battery. The battery fluid will
be lost through continuous charging and discharging.
Before starting , check for physical damage to the
battery and also the electrolyte level, and replenish
with distilled water up to the upper mark if necessary.
When actual damage is discovered , replace the battery
immediately. Batteries are covered by 12 months
warranty from the original date of purchase.
STORAGE
If your generator should be stored in long time, the
following preparation should be made.
1. Operate the diesel engine about 10 minutes with NO
load and stop it.
2. Wait approx. 10 mins when the engine is still warm,
drain engine oil out, then refill new 10W30 engine oil.
WPE DIESEL GENERATORS TROUBLESHOOTING
9
EN
TROUBLESHOOTING
Problem Cause Solution
Engine will not start.
No fuel. Add fuel.
The battery is flat Recharge or replace
Check oil level Add oil if needed
Valve clearance is not correct Adjust the clearance as per operational
manual
Piston ring worn or rings in wrong
place Change and adjust piston ring
Bolts of cylinder head are not tight Tighten the bolts
Engine is running but no output.
AC circuit breaker is turned ‘OFF’ Put the main AC switch to the “ON” position
The contact of socket is not good Adjust the feet of socket
AVR is broken Replace AVR
Other. Contact Technical Support
service@bpeholdings.co.uk.
WPE DIESEL GENERATORS TECHNICAL SPECIFICATIONS
10
TECHNICAL SPECIFICATIONS
MODEL: LDG12S LDG12S3
Type Single Phase A.C 3 Phase
Frequency (Hz) 50 50
Rated Power (kW) 10 10
Max Power (kW) 11 11
Voltage (A.C) 110,115,120, 220,230,240,120/240 220/380,240/415
Power Factor 1.0 0.8
Engine Type LA290F
Type 4 Stroke, Twin cylinder, air cooled
Speed (rpm) 3000
Start System Electric Start
Fuel Diesel
Fuel Capacity (L) 50
Operation capacity (hr) <12
Nett Weight (kg) 295 300
Dimensions (L x W x H) mm 1160 x 675 x 945
WPE DIESEL GENERATORS WARRANTY
11
EN
WARRANTY
We at Warrior understand the importance of warranty for service & repair, we are now offering a standard 2 Year (Warrior Diesel Generators)
without the need for registering your purchase. We still have the option for product registration for customer who still would like to use the website
and to keep in touch with ourselves.
Please view the limitations below and read the full T&C’s about the warranty offered on a particular product.
All we require is the either a copy of the original proof of purchase or an invoice supplied from retailer at the time of purchase to enable the claim
to be raised. Please keep your proof of purchase safe for the duration of your terms, in the unfortunate event you need our technical support we
will ask for this to be provided on each claim, NO proof of purchase any warranty claim will be delayed or rejected.
Repair / Replacement Warranty
Warrior branded diesel generators warrants to the original purchaser up to 2 Years for domestic usage that the mechanical and electrical
components will be free of defects in material and workmanship for a period of Year One (1) [Parts and Labour] Year Two (2) [Parts Only] from the
original date of purchase or 1000 hours which ever comes first.
Industrial & Commercial Use One Year (1) [Parts and Labour] or 500 hours which ever comes first.
Transportation charges on any product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This
warranty only applies to the original purchaser and is not transferable.
Do Not Return the Unit to the Place of Purchase
Contact Warrior Technical Service and we will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, Warrior
will, at its option, authorise evaluation, repair or replacement of the defective part or component at our own Service Center. If and when an
product has to be replaced it will be on a like for like basis not old for new. Warrior will provide you with a case number for warranty service and
this can be monitored through your login account. Please keep it for future reference. Repairs or replacements without prior authorization, or at
an unauthorized repair facility, will not be covered by this warranty. We do have warranty exclusions for customers outside the United Kingdom
please see our full T&C’s.
Warranty Exclusions
This warranty DOES NOT cover the following:
Normal Wear
Your product needs periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a
part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts or labour if your product is deemed to have been misused, neglected, involved in an accident, abused,
overloaded beyond the generators limits, modified, installed improperly or connected incorrectly to any electrical component or system. Normal
maintenance is not covered by this warranty.
Other Exclusions
This warranty excludes:
– cosmetic defects such as paint, decals, etc.,
– worn parts including piston & rings, spark plugs, filters
– accessory parts including wheels & recoil assemblies
– failures due to acts of God and other force majeure events beyond the manufacturer’s control
– problems caused by parts that are not original Warrior Power Equipment parts
- alteration or modification(s) made by any party other than the manufacturer including exhaust extension and filtration systems.
- all hoses plastic or rubber, reducing valves and regulators
- any third party electrical equipment
12v Battery
– All batteries supplied Over 1 Year Old.
Suitable Transfer Switch
Any MTS (Manual Transfer) & ATS (Automatic Transfer) systems other that ones supplied by ourselves under WARRIOR or Warrior will not be
considered suitable and will invalidate all warranties given. Please contact us direct before installing any Transfer system.
Limits of Implied Warranty and Consequential Damage
Winch Solutions Ltd (CG) disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim
costs by anyone using this product.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will
remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from
country to country. Your country may also have other rights you may be entitled to that are not listed within this warranty.
WPE DIESEL GENERATORS EINLEITUNG
12
EINLEITUNG
Vielen Dank, dass Sie unser Produkt gekauft haben.
Auf dieses Produkt gewähren wir eine 24-monatige
Garantie gegen Herstellungsfehler ab dem Kaufdatum.
Bitte bewahren Sie Ihre Kaufquittung als Beleg für den
Kauf auf.
Diese Garantie ist ungültig, wenn das Produkt in
irgendeiner Weise missbräuchlich verwendet,
manipuliert oder nicht für den vorgesehenen Zweck
verwendet wurde. Defekte Produkte sollten nicht
an den Händler, sondern der Generator sollte an den
Lieferanten des Produkts zurückgegeben werden
Kein Produkt kann ohne vorherige Genehmigung
zurückgegeben werden. Diese Garantie schränkt Ihre
gesetzlichen Rechte nicht ein.
Wenn Sie sich wegen Ersatzteilen und/oder Service an
WPE wenden, müssen Sie die vollständige Modell- und
Seriennummer Ihres Produkts angeben. Übertragen
Sie die Informationen, die Sie auf dem Typenschild Ihres
Produkts finden, in die folgende Tabelle.
WPE TECHNISCHER SUPPORT
MODELLNUMMER
SERIENNUMMER
KAUFDATUM
ORT DES KAUFS
WICHTIG
1. Kinder dürfen den Generator NIEMALS bedienen und
ssen sich in sicherer Entfernung von ihm aufhalten.
2. Ihr neuer Generator benötigt nach einer Betriebsdauer
von 10 Stunden eine Ruhephase, in der er NICHT mit mehr
als zu 75% der maximalen Last belastet wird. Nach den
ersten 10 Betriebsstunden MUSS das Öl gewechselt
werden, empfohlenes Öl 10W30 („Low“ oder „Non
Synthetic“).
3. Berühren Sie nicht den Motor oder den Auspuff, wenn der
Generator in Betrieb ist. Bitte beachten Sie die Warn- und
Hinweisaufkleber auf dem Generator.
4. Die elektrischen Geräte (einschließlich der Kabel und der
Steckverbindungen) müssen sich in einem guten Zustand
befinden und vor der Inbetriebnahme überprüft werden.
5. Wenn ein Schutzschalter ausgetauscht wird, muss dieser
den gleichen Anforderungen entsprechen oder besser
sein als der, der entfernt wird.
6. Aufgrund der hohen mechanischen Belastung wird
empfohlen, nur Kabel mit Gummiummantelung zu
verwenden.
7. Beim Einsatz von Verlängerungskabeln oder mobilen
Verteilerschränken sollte das Kabel mit einem Querschnitt
von 1,5 mm2 nicht länger als 50 Meter sein; bei einem
Querschnitt von 2,5 mm2 nicht länger als 100 Meter.
8. Beim manuellen Start immer den Dekompressionshebel
betätigen. (NUR bei Open-Frame-Typ)
9. Bei normalen Umgebungsbedingungen (minus 5 bis
40 Grad Celsius) kann der Generator bei normaler
Betriebslast betrieben werden. Wenn die Temperatur
entweder zu hoch oder zu niedrig ist, sollte der Generator
mit einer geringeren Leistung von nicht mehr als 75% der
maximalen Last betrieben werden. Wenn die Temperatur,
die Höhe und die Luftfeuchtigkeit höher sind als die
Standardbetriebsbedingungen, MUSS die Ausgangslast
des Generators auf höchstens 75% der maximalen Last
reduziert werden.
10. Vor jeder Inspektion oder Wartung des Generators den
Motor abstellen und mindestens 30 Minuten abkühlen
lassen. Den Generator gemäß der Tabelle und dem
Zeitplan im Handbuch überprüfen und warten.
11. Mit Ausnahme der täglichen Wartung und Reinigung
sollte jede Inspektion oder Anpassung von autorisiertem
Fachpersonal durchgeführt werden, das die erforderlichen
Originalteile vom Lieferanten bezieht. (Kontaktieren Sie
Ihren Händler vor Ort).
12. Die frisch revidierte Maschine muss eine Einlaufphase von
mindestens 10 Stunden überstehen, wobei die Leistung
75% der maximalen Last nicht überschreiten sollte.
WPE DIESEL GENERATORS FUNKTIONEN
13
DE
FUNKTIONEN
Der WPE Dieselgenerator hat folgende Funktionen:
Bei dieser Serie handelt es sich um extrem leichte,
luftgekühlte Dieselmotoren mit Direkteinspritzung, die
über zwei Startoptionen verfügen:
1. Anreißstarter
2. Elektrischer Starter.
Sie verfügen über einen Kraftstofftank mit großem
Fassungsvermögen, einen Stromkreisschutz, Wechsel-
und manchmal Gleichspannungsausgänge, einen
Alarm für niedrigen Öldruck und eine automatische
Abschaltvorrichtung.
Der Dieselgenerator dient als USV-Notstromversorgung
in vielen verschiedenen Anwendungen, unter anderem
auf Baustellen, bei der Armee usw. Notstromversorgung
für Geflügelzucht, Fischerei, Forstwirtschaft, Garten,
Hotel, Geschäft und Büro.
In diesem Handbuch erfahren Sie, wie Sie Ihren neuen
Dieselgenerator bedienen und warten können. Bitte
lesen Sie es, bevor Sie den Dieselgenerator in Betrieb
nehmen, um eine korrekte Handhabung und Bedienung
sicherzustellen. Wenn Sie diese Anweisungen sorgfältig
befolgen, bleibt Ihr Dieselgenerator in einem optimalen
Betriebszustand und Sie können die Lebensdauer des
Gerätes verlängern.
Wenn Sie Fragen zu Ihrem neuen Produkt oder zu den
in diesem Handbuch enthaltenen Informationen haben,
wenden Sie sich bitte an service@bpeholdings.co.uk.
KENNZAHLEN
Die Generatoren können die angegebene Leistung
erzeugen, wenn sie unter den folgenden Bedingungen
eingesetzt werden:
Höhe: < 1000m
Umgebungstemperatur: 5 bis 40°C
Relative Luftfeuchtigkeit: <90%
WARNUNG
Auspuff/Auspufftopf und Gase können sehr heiß
sein. KEINE Auspuff-/Auspufftopfverlängerungen
hinzufügen oder montieren, da dadurch jegliche
Garantie erlischt.
Verbrennungen verhindern
Berühren Sie NIEMALS den Auspuff/Auspufftopf oder
den Motor, wenn der Generator läuft oder heiß ist. Lassen
Sie den Auspuff/Auspufftopf und den Motor immer ca. 30
Minuten abkühlen, bevor Sie ihn anfassen.
WICHTIG
Lesen Sie diese Bedienungsanleitung aufmerksam
durch, um einen sicheren Betrieb zu gewährleisten, und
achten Sie besonders auf die folgenden Hauptpunkte,
da es sonst zu Verletzungen und Schäden am Gerät
kommen kann.
Brände verhindern
Der Kraftstoff für den Dieselmotor ist leichter
Dieselkraftstoff, daher dürfen Sie NIEMALS Benzin,
Kerosin usw. verwenden.
Wischen Sie verschütteten Kraftstoff mit einem
sauberen Tuch auf. Achten Sie darauf, dass Benzin,
Kerosin, Streichhölzer und andere explosive und
brennbare Stoffe nicht in die Nähe des Generators
gelangen, da die Temperatur im Bereich des
Auspufftopfes während des Betriebs sehr hoch
ist. Um Brandgefahren zu vermeiden und eine
ausreichende Belüftung zu gewährleisten, sorgen
Sie dafür, dass der Generator während des Betriebs
mindestens 1,5 Meter von Gebäuden, Strukturen und
anderen Geräten entfernt ist.
Betreiben Sie den Generator auf einer ebenen Fläche.
Wenn der Generator schief steht, kann Kraftstoff
verschüttet oder der Betrieb beeinträchtigt werden.
Einatmen von Abgasen verhindern
Die Abgase enthalten giftiges Kohlenmonoxid.
Verwenden Sie den Generator immer im Freien,
mindestens 1,5 m von Fenstern, Türen oder Öffnungen
entfernt.
Generatoren DÜRFEN NIEMALS in Innenräumen,
Garagen, Hütten, Nebengebäuden, Schuppen oder
anderen geschlossenen Räumen, einschließlich
Fahrzeugen und Fahrzeugabteilen, verwendet werden.
Stromschläge, Kurzschlüsse
Um Stromschläge oder Kurzschlüsse zu vermeiden,
sollten Sie den Generator nicht mit nassen Händen
anfassen.
Dieser Generator ist nicht wasserdicht und sollte daher
NIEMALS an Orten verwendet werden, die dem Einfluß
von Regen, Schnee oder Wasserspritzern ausgesetzt
sind. Der Generator sollte geerdet sein, um Stromschläge
zu vermeiden. Verbinden Sie ein dickes Kabel zwischen
dem Erdungsanschluss des Generators und einer
externen Erdungsvorrichtung, einem Erdungsstab oder
-spieß – mindestens 200 mm tief.
Schließen Sie keine Geräte an den Generator an, bevor
Sie ihn starten.
WPE DIESEL GENERATORS VORBEREITUNG VOR DEM START
14
WARNUNG
Die meisten Motoren von Geräten benötigen zum
Starten mehr als ihre Nennleistung. Überschreiten
Sie nicht die für eine einzelne Steckdose
angegebene Obergrenze für den Strom.
Aufladen der Batterie
Batterieelektrolyt enthält Schwefelsäure. Schützen
Sie Ihre Augen, Haut und Kleidung. Bei Kontakt spülen
Sie alles gründlich mit Wasser aus und suchen Sie
umgehend einen Arzt auf, insbesondere wenn Ihre Augen
betroffen sind.
Batterien erzeugen Wasserstoffgas, wodurch es
in der Nähe einer Batterie zu Entzündungen oder
Funkenbildung kommen kann, insbesondere beim Laden.
Laden Sie den Akku in einem gut belüfteten Bereich auf.
WARNUNG
Informieren Sie sich darüber, wie Sie den Generator
schnell abschalten können und wie die einzelnen
Bedienelemente funktionieren. Erlauben Sie
niemandem, den Generator ohne entsprechende
Anleitung zu bedienen.
Tragen Sie immer einen Helm, Sicherheitsschuhe
und angemessene Kleidung. Achten Sie darauf,
dass Haustiere und Kinder nicht in die Nähe des
Generators gelangen, wenn dieser in Betrieb ist.
VORBEREITUNG VOR DEM START
Auswahl und Verwendung von Kraftstoff
Es darf nur leichter Dieselkraftstoff verwendet
werden.
Der Kraftstoff muss gefiltert werden.
Der Kraftstoff darf kein Wasser oder Staub enthalten,
da diese das Einspritzsystem verunreinigen können.
Achten Sie darauf, dass Sie den Tank nicht über die
Oberkante des roten Stopfens im Kraftstofftankfilter
hinaus auffüllen. Verwenden Sie die Tankanzeige
oben auf dem Tank.
In dem Bereich, in dem der Motor aufgetankt wird oder
in dem Benzin gelagert wird, ist Rauchen verboten und
es dürfen keine Funken entstehen.
Achten Sie darauf, dass Sie beim Tanken keinen
Kraftstoff verschütten und der Filterdeckel fest
verschlossen ist.
Auswahl und Verwendung von Öl
Prüfen Sie den Ölstand vor jedem Einsatz.
Stellen Sie den Generator auf eine gerade Fläche.
Sie finden den Ölmessstab, wenn Sie die Tür öffnen.
Um den Ölstand zu prüfen, tauchen Sie einfach den
Ölmessstab in die Ölwanne. Schrauben Sie den
Ölmessstab beim Prüfen nicht ein.
HINWEIS
Nichts beeinflusst die Leistung und Lebensdauer
des Generators mehr als das Öl, das Sie verwenden.
Wenn Sie qualitativ minderwertiges Öl verwenden
oder das Motoröl nicht regelmäßig wechseln, erhöht
sich das Risiko von Kolbenfressern, klebenden
Kolbenringen und beschleunigtem Verschleiß
von Zylinderlaufbuchsen, Lagern und anderen
beweglichen Komponenten erheblich.
Prüfen Sie unbedingt den Ölstand und füllen Sie Öl
bis zum vorgeschriebenen Pegel nach, bevor Sie
den Generator starten, auch wenn er mit einem
Warnsystem für niedrigen Öldruck ausgestattet ist.
Wenn Ihr Generator beim 5. Versuch nicht anspringt
oder nach dem Start ausfällt, ist der Ölstand zu
niedrig und muss nachgefüllt werden.
HINWEIS
Das Öl sollte nach den ersten 20 Betriebsstunden
(oder 1 Monat) und dann alle 3 Monate oder 100
Betriebsstunden gewechselt werden.
Lassen Sie das Öl ab, wenn der Motor warm, aber
nicht heiß ist. Nach dem Abkühlen ist es schwierig,
das Öl vollständig abzulassen.
WARNUNG
NIEMALS bei laufendem Motor Öl in den Generator
einfüllen oder versuchen, es zu wechseln.
WPE DIESEL GENERATORS BETRIEB
15
DE
Luftfilter prüfen
Die Flügelmutter lösen, den Deckel des Luftfilters
abnehmen und das Element entfernen. Das
Luftfilterelement nicht mit einem Reinigungsmittel
waschen. Wasser oder Benzin verwenden (MUSS vor
dem Wiedereinsetzen trocken sein).
Das Luftfilterelement muss ausgetauscht werden,
wenn die Motorleistung nachlässt oder die Farbe der
Abgase ungewöhnlich ist.
Betreiben Sie den Generator niemals ohne das
Luftfilterelement. Dies kann zu einem schnellen
Verschleiß des Motors führen.
Bringen Sie die Abdeckung des Luftfilters wieder an
und ziehen Sie die Flügelmutter fest.
Sicherstellen, dass der Generator nicht
belastet wird.
Den Hauptstromkreisunterbrecher und alle anderen
Lasten ausschalten.
Stellen Sie sicher, dass der Hauptschalter
ausgeschaltet ist, bevor Sie den Generator starten.
Ist der Schalter nicht in der Position „OFF“, kann eine
plötzliche Belastung beim Anlassen des Dieselmotors
sehr gefährlich sein.
Der Generator sollte geerdet sein, um Stromschläge
zu vermeiden. (Empfohlen).
Bedienung eines
Doppelspannungsgenerators
Betätigung des Umschalters: Bevor Sie das Gerät in
Betrieb nehmen, muss der Wechselstromschalter
am Bedienfeld auf „OFF“ gestellt werden. Nach
dem Start des Generators die Drehzahl auf
Nenndrehzahl hochfahren lassen und dann den
Wechselstromschalter auf „ON“ schalten, damit die
Steckdosen für den Betrieb von Geräten genutzt
werden können.
Versuchen Sie NIEMALS, zwischen den Spannungen
umzuschalten, wenn der Wechselstromschalter
eingeschaltet und das Gerät eingesteckt ist.
Stellen Sie den Wechselstromhauptschalter
in die Position „OFF“, wenn Sie die
12-V-Gleichstromversorgung verwenden.
Auf Luftschleuse prüfen
WARNUNG
Der KRAFTSTOFF und das MOTORENÖL werden
vor dem Transport werksseitig abgelassen. Die
Generatoren werden trocken gelagert.
Prüfen Sie, ob sich Luft in der Kraftstoffleitung
befindet. Falls ja, lassen Sie die Luft aus der Leitung
ab, bevor Sie tanken und den Dieselmotor starten.
Der Kraftstofffilter sollte zu mindestens 75% gefüllt
sein, andernfalls kann sich Luft im System befinden.
Die 17-mm-Stopfbuchsendichtung zwischen der
Einspritzpumpe und der Hochdruck-Messingleitung
lösen, den Starthebel in die Position „RUN“ stellen und
den Motor drehen, bis der Kraftstoff herausspritzt.
Die 17-mm-Stopfbuchsendichtung wieder einsetzen
und anziehen und den Vorgang wiederholen, wenn der
Motor immer noch nicht anspringt.
BETRIEB
Vorwärmer-Funktion
Dieser Generator ist mit einer Vorwärmer-Funktion
für kalte Temperaturen unter 0°C ausgestattet. Diese
Funktion dient dazu, den Motor und das Öl mit Hilfe der
von der Batterie gelieferten 12-V-Gleichstromversorgung
aufzuwärmen, bevor der Motor angelassen wird.
Wenn die Außentemperatur unter 0°C liegt, wird
empfohlen, vor dem Anlassen des Motors zuerst die
Vorwärmtaste zu betätigen.
1. Drehen Sie den Zündschlüssel in die Stellung ‚ON‘.
2. Drücken Sie die Vorwärmtaste und halten Sie sie
mindestens 5 Sekunden lang gedrückt, bis die rote
Kontrollleuchte leuchtet.
3. Lassen Sie die Taste los und starten Sie den
Generator normal mit dem Schlüssel oder der
Fernbedienung (nur bei Modellen mit Fernbedienung).
Wenn der Generator nicht anspringt, wiederholen Sie
die Schritte 1-3 maximal 3 Mal. Wenn der Generator nach
3 Versuchen nicht anspringt, wenden Sie sich an Ihren
örtlichen Kundendienst.
Warnsystem für niedrigen Ölstand
Das Gerät schaltet den Motor automatisch ab, wenn
der Öldruck unter den vorgeschriebenen Wert fällt,
und verhindert ein Blockieren des Motors, wenn das
Motoröl zu niedrig ist oder der Motordruck abfällt.
Wenn der Motor mit zu wenig Motoröl betrieben wird,
steigt die Öltemperatur stark an. Allerdings ist ein zu
hoher Ölstand gefährlich, da sich das Öl entzünden
und einen plötzlichen und übermäßigen Anstieg der
Motordrehzahl verursachen kann. Prüfen Sie daher
vor jedem Einsatz der Maschine den Ölstand und
füllen Sie bei Bedarf Öl bis zum vorgeschriebenen
Pegel auf.
WPE DIESEL GENERATORS BETRIEB
16
Warnleuchte für niedrigen Ölstand
Ihr Generator ist mit einer Warnleuchte für niedrigen
Ölstand ausgestattet.
Wenn die Leuchte dauerhaft rot leuchtet, muss Ihrem
Generator sofort Öl nachgefüllt werden.
1. Stoppen Sie sofort den Betrieb der Maschine, stellen
Sie den Motor ab und lassen Sie ihn ca. 10-15 Minuten
abkühlen.
2. Entfernen Sie den Ölmessstab und reinigen Sie ihn.
3. Füllen Sie Öl mit einem Öltrichter (nicht mitgeliefert)
ein und prüfen Sie den Ölstand mit dem Ölmessstab
(als allgemeine Regel gilt, dass das Öl voll ist, wenn
es am mittleren/oberen Gewinde des Anschlusses
zu sehen ist). Wenn Sie den Ölmessstab verwenden,
schrauben Sie ihn NIEMALS ein, um den Ölstand
abzulesen, sondern halten Sie ihn einfach oben am
Anschluss an und sehen Sie sich den Stand an.
4. Schrauben Sie den Ölmessstab wieder ein.
5. Lassen Sie den Motor 10 Minuten lang ohne Last
laufen, damit das Öl vollständig zirkulieren kann.
6. Prüfen Sie den Ölstand erneut.
Wird die empfohlene Ölmenge nicht nachgefüllt, kann
dies zu erhöhtem Motorverschleiß und (oder) zu Schäden
am Motor führen.
Tür und Deckel des Gehäuses öffnen.
Öffnen Sie die Schranktür, klappen Sie sie auf und
überprüfen Sie sie täglich.
7. Drehen Sie den Griff gegen den Uhrzeigersinn, um
die Schranktür zu öffnen.
8. Drehen Sie den Griff im Uhrzeigersinn, um die
Schranktür zu verriegeln.
Einlaufphase
Solange Ihr Generator noch neu ist, können schwere
Lasten die Lebensdauer des Motors verkürzen.
Halten Sie sich während der ersten 20 Stunden an die
Anleitungen zum Einlaufen.
1. Vermeiden Sie während der Einlaufphase jede
schwere Belastung.
2. Wechseln Sie regelmäßig das Motoröl. Wechseln Sie
das Motoröl alle 20 Stunden oder einen Monat nach
der ersten Benutzung und danach alle 3 Monate oder
100 Stunden.
Starten des Generators
Elektrischer Start
1. Schalten Sie den Wechselstromschalter in die
Position „OFF. Stellen Sie sicher, dass der Generator
geerdet ist (empfohlener 200mm Erdungsstab).
2. Drehen Sie den Zündschlüssel auf die Position
„Start“ (nicht länger als 8 Sekunden).
3. Nehmen Sie die Hand vom Schlüssel, sobald
der Motor startet, und lassen Sie den Schlüssel
automatisch in die Ausgangsposition zurückkehren.
WARNUNG
Wenn der Startmotor nicht anspringt, warten Sie
bitte mindestens 30 Sekunden, bevor Sie den
Startvorgang wiederholen.
WARNUNG
Hinweis: Wenn der Startmotor zu lange läuft, wird die
Batterie entladen.
Batterie
Prüfen Sie den Flüssigkeitsstand in der Batterie einmal
pro Monat. Wenn der Pegel auf die untere obere
Markierung fällt, füllen Sie destilliertes Wasser bis zur
oberen Markierung nach.
Wenn zu wenig Batterieflüssigkeit vorhanden ist, springt
der Motor möglicherweise nicht an, da nicht genügend
Strom zum Anlasser gelangt. Achten Sie darauf, dass
der Pegel immer zwischen dem oberen und dem unteren
Pegel liegt.
Wenn zu viel Batterieflüssigkeit aufgetragen wird, kann
die Flüssigkeit auslaufen und die umliegenden Teile
korrodieren. NICHT überfüllen.
Für die Batterien gilt lediglich eine Garantie von 1 Jahr ab
dem Kaufdatum.
Betrieb des Generators
1. Lassen Sie den Motor etwa 10 Minuten lang ohne
Last warmlaufen.
2. Unser Generator ist mit einem Warnsystem
ausgestattet, das einen niedrigen Ölstand anzeigt.
Bei niedrigem Öldruck oder Schmierölmangel wird
der Motor automatisch abgeschaltet. Der Motor
bleibt sofort stehen, wenn Sie ihn erneut starten,
ohne Schmieröl nachzufüllen. Ölstand prüfen und
nachfüllen
3. Lösen Sie weder die Schraube zur Begrenzung der
Motordrehzahl noch die Schraube zur Begrenzung
WPE DIESEL GENERATORS WARTUNG
17
DE
der Kraftstoffeinspritzung (sie sind werkseitig
eingestellt) und stellen Sie sie nicht neu ein, da
sonst die Leistung und der Kraftstoffverbrauch
beeinträchtigt werden.
Kontrolle während des Betriebs
1. Irgendwelche abnormalen Geräusche oder
Vibrationen?
2. Der Motor zündet nicht richtig oder läuft unrund.
3. Wie sieht die Farbe der Abgase aus? (schwarz oder
zu weiß?)
Wenn Sie eines der oben genannten Symptome
bemerken, stellen Sie den Motor ab und wenden Sie sich
an Ihren nächsten Händler oder an den technischen
Kundendienst unter [email protected].
Wechselstrombetrieb
1. Starten Sie den Motor und vergewissern Sie sich,
dass die GRÜNE Kontrolllampe leuchtet. Ist dies nicht
der Fall,nnte der Glühdraht durchgebrannt sein.
2. Die Drehzahl des Generators muss die Nenndrehzahl
erreichen (Hebel nach oben).
3. Der Generator kann belastet werden, wenn die
Anzeige des Voltmeters auf dem Bedienfeld des
Schaltkastens 240±10% (50Hz) anzeigt.
4. Schließen Sie das Gerät an.
WARNUNG
Starten Sie nicht zwei oder mehr Maschinen
gleichzeitig. Starten Sie eine nach der anderen.
Verwenden Sie Scheinwerfer nicht zusammen mit
anderen Geräten.
5. Stellen Sie sicher, dass alle Geräte in einwandfreiem
Zustand sind, bevor Sie sie an den Generator
anschließen.
6. Wenn ein Gerät oder eine Anlage abnormal läuft,
träge wird oder plötzlich stehen bleibt, schalten Sie
den Generator sofort aus. Trennen Sie dann das
Gerät vom Stromnetz und untersuchen Sie es auf
Anzeichen einer Fehlfunktion.
7. Wenn eine Überlastung des Stromkreises den
Wechselstromschutz auslöst, reduzieren Sie die
elektrische Belastung des Stromkreises und warten
Sie einige Minuten, bevor Sie den Betrieb wieder
aufnehmen.
8. Wenn die LCD-Anzeige des Spannungsmessers zu
niedrig oder zu hoch ist, halten Sie das Gerät an und
versuchen Sie, die Ursache des Fehlers zu finden.
Stoppen des Generators
1. Schalten Sie den Generator NICHT aus, wenn
er unter Last steht. Dies kann den Generator
beschädigen.
2. Schalten Sie den Wechselstromschalter aus.
3. Drehen Sie den Zündschlüssel gegen den
Uhrzeigersinn in die Position „OFF“.
WARTUNG
Regelmäßige Kontrolle und Wartung sind sehr wichtig,
um den Motor in gutem Zustand zu halten. Bitte lesen
Sie für jedes Teil die detaillierte Beschreibung der
Bedienungsanleitung.
Stellen Sie den Motor ab, bevor Sie eine Wartung
durchführen. Wenn der Motor in Betrieb ist, stellen Sie
sicher, dass der Bereich gut belüftet ist. Die Abgase
enthalten giftiges Kohlenmonoxidgas.
Reinigen Sie den Motor nach der Benutzung sofort
mit einem Tuch, um Korrosion zu verhindern und
Ablagerungen zu entfernen.
GLICH
Ölstand prüfen
Kraftstoff prüfen und auffüllen
Auf Ölleckagen prüfen
Batterieflüssigkeit
Luftreiniger
Motorteile prüfen und festziehen, wenn sie lose
sind
DIE ERSTEN 20 STUNDEN
Öl wechseln
Ölfilter reinigen
ALLE 100 STUNDEN ODER ALLE 3 MONATE
Öl wechseln
Ölfilter wechseln
Kraftstofffilter wechseln
Luftfilter reinigen
Ventilspiel prüfen/einstellen*
ALLE 2 JAHRE
Kraftstoffleitung ersetzen*.
* Es sind spezielle Werkzeuge und Kenntnisse erforderlich
– versuchen Sie es nicht selbst – wenden Sie sich an den
technischen Support unter service@bpeholdings.co.uk.
Wechsel des Motoröls (alle 100 Stunden)
Füllen Sie das empfohlene Öl 10W30 (nicht oder
teilsynthetisch) nach.
WPE DIESEL GENERATORS LAGERUNG
18
1. Linke Tür öffnen, mit der Gabel die Ablassschraube
lösen (Schraube nicht herausdrehen), die
Ölführungsrille unter die Ablassschraube schieben,
den Auslass mit dem Ölbehälter verbinden und dann
die Ölablassschraube vollständig entfernen.
2. Beginnen Sie damit, das Öl abzulassen, und wenn
die Ölwanne leer ist, verwenden Sie gegebenenfalls
den Diesel, um die Innenseite des Zylinderblocks zu
reinigen.
3. Die Ablassschraube wieder einsetzen.
4. Den runden Kunststoffdeckel auf der Oberseite
der Lichtmaschine verschieben, den Öldeckel des
Zylinderkopfs abschrauben, das Öl einfüllen, bis die
Ölanzeige den Maximalwert erreicht hat, und dann
den Zylinderkopfbolzen wieder festschrauben.
Reinigung des Luftfilters (alle 100 Stunden)
Wenn Sie die obere Platte und die hintere Abdeckung
des Generators verschieben, sehen Sie den Luftfilter.
Die Klammer lösen, die untere Hälfte des Luftfilters
herausnehmen und das Filterelement in der Mitte
entnehmen; das Filterelement mit Dieselkraftstoff
waschen und wieder in den Luftfilter einsetzen, nachdem
es getrocknet ist.
Prüfen und Auffüllen der Batterieflüssigkeit und
Laden der Batterie (monatlich)
Dieser Dieselmotor verwendet eine 12-V-Batterie. Die
Batterieflüssigkeit geht durch ständiges Laden und
Entladen verloren.
Die Batterie vor dem Start auf physische Schäden und
ebenfalls den Elektrolytstand prüfen und gegebenenfalls
destilliertes Wasser bis zur oberen Markierung
nachfüllen. Ersetzen Sie die Batterie sofort, wenn Sie
einen Schaden feststellen. Für die Batterien gilt eine
Garantie von 12 Monaten ab dem Kaufdatum.
LAGERUNG
Wenn Sie Ihren Generator für längere Zeit einlagern
möchten, sollten Sie folgende Vorbereitungen treffen.
1. Lassen Sie den Dieselmotor etwa 10 Minuten ohne
Last laufen und schalten Sie ihn dann ab.
2. Warten Sie ca. 10 Minuten und, wenn der Motor noch
warm ist, lassen Sie das Motoröl ab und füllen Sie
neues 10W30 Motoröl nach.
WPE DIESEL GENERATORS FEHLERSUCHE
19
DE
FEHLERSUCHE
Problem Ursache Lösung
Motor startet nicht
Kein Kraftstoff Kraftstoff auffüllen.
Die Batterie ist leer Aufladen oder ersetzen
Ölstand prüfen Bei Bedarf Öl hinzufügen
Das Ventilspiel ist nicht korrekt Stellen Sie das Spiel wie im
Betriebshandbuch beschrieben ein
Kolbenring abgenutzt oder Ringe
an falscher Stelle Kolbenring wechseln und einstellen
Die Schrauben des Zylinderkopfes
sind nicht fest genug angezogen Die Bolzen anziehen
Der Motor läuft, aber keine
Leistung
Der Wechselstromschalter ist
ausgeschaltet
Stellen Sie den
Wechselstromhauptschalter auf die
Position „ON
Der Kontakt der Steckdose ist
mangelhaft Die Füße der Steckdose anpassen
AVR ist defekt ARV ersetzen
Sonstiges Technischer Support kontaktieren
service@bpeholdings.co.uk.
WPE DIESEL GENERATORS TECHNISCHE DATEN
20
TECHNISCHE DATEN
MODELL: LDG12S LDG12S3
Typ Einphasiger Wechselstrom 3 Phasen
Frequenz (Hz) 50 50
Nennleistung (kW) 10 12,5
Max. Leistung (kW) 11 13,75
Spannung (Wechselstrom) 110,115,120, 220,230,240 220/380
Leistungsfaktor 1,0 0,8
Motortyp 296F
Typ 4-Takt, Zweizylinder, luftgekühlt
Drehzahl (U/min) 3000
Startsystem Elektrischer Start
Kraftstoff Diesel
Tankvolumen (L) 60
Betriebskapazität (Std.) <12
Nettogewicht (kg) 295 300
Abmessungen (L x B x H) mm 1160 x 675 x 945
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73

WARRIOR LDG12S Manuale utente

Categoria
Generatori di corrente
Tipo
Manuale utente
Questo manuale è adatto anche per