Haier 1U09BS1ERA Guida d'installazione

Categoria
Condizionatori d'aria a sistema split
Tipo
Guida d'installazione

Questo manuale è adatto anche per

Please read this manual carefully before installtion.
Keep this operation manual for future reference.
1U12BS1ERA
1U09BS1ERA
1U07BS1ERA
1U18FS1ERA
1U24GS1ERA
INSTALLATION MANUAL
ROOM AIR CONDITIONER
NO.0010535386
14
1
2
9
Indoor/Outdoor Unit Installion Drawings
Safety Precautions
Installation Procedure
Outdoor Unit Troubleshooting
Read Before Installation
6
Contents
Contenido
Unidad interior y exterior Dibujos de extracción
15
Precauciones de seguridad 16
Leer antes de realizar la instalación 20
Procedimiento instalación 23
Unidad interior Resolución de problemas
28
Indice
Unità esterna/interna Immagini per l'installazione
29
Precauzioni di sicurezza
30
Leggere prima dell'installazione
34
Processo di installazione
37
Unità esterna Risoluzione dei problemi
42
Table des matières
Unité intérieure/extérieure Schémas d'installation
43
Consignes de sécurité
À lire avant l'installation
Procédure d'installation
Unité extérieure Dépannage
56
44
48
51
Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China
CE
All the products are in conformity with the following
European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the
directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU
RoHS Directive)
WEEE
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste. Do not try to dismantle the
system yourself : the dismantling of the air
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
1
1+2=
kg
R410A
2
kg
2=
1=
B
C
D
FE
kg
A
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field
and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the
product
charging port (e.g. onto the inside of the stop value
A contains fluorinated greenhouse gases covered by the
Kyoto
Protocol
B factory refrigerant charge of the product: see unit name
plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
In accordance with the directive 2002/96/CE of the European
parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in
accordance
with relevant local and national legislation. Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and
nationl legislation.
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
cover).
Please be subject to the actual product purchased.
The above indoor and outdoor units’ picture is just for your reference.
F
A
C
E
D
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle(L.S)withscrews
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Fixing of outdoor unit
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
ƽ
surface,rooforrooftop,fix
asupportersurelywithnails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
ƽ
house, fix the unit by attaching a
vibration-proof mat.
The marks from to
in the figure are the
parts numbers.
Thedistancebetween
theindoorunitandthe
floor should be more
than 2m.
ThemodelsadoptHFCfreerefrigerantR410A.
more than
10cm
more than 15cm
more than 10cm
more than 20cm
more than
20cm
more than 25cm
more than
60cm
A
G
ƽ
ƽ
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Attention must be paid to
the rising up of drain hose
Indoor/Outdoor Unit Installation Drawings
For installation of the indoor units,refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
ƽ
Compressor(Inside of Unit)
1
WARNING
CAUTION
2
Have the unit professionally installed.
Improper installation by an unqualified person may result
in water leak, electric shock, or fire.
Be sure to carefully follow each step in this handbook when
installing the unit.
Improper installation may result in water leak, electric shock,
smoke or fire.
Have all electrical work performed by a licensed electrician
according to the local regulations and the instructions given
in this manual. Secure a circuit designated exclusively to
the unit.
Improper installation or a lack of circuit capacity may cause
the unit to malfunction or present a risk of electric shock,
smoke,and fire.
Place the unit on a stable, level surface that withstands the
weight of the unit to prevent the unit from tipping over or
falling causing injury as a result.
Only use specified cables for wiring. Securely connect each
cable, and make sure that the cables are not straining the
terminals.
Cables not connected securely and properly may generate
heat and cause fire.
Take necessary safety measures against typhoons and
earthquakes to prevent the unit from falling over.
Do not make any changes or modifications to the unit. In
case of problems, consult the dealer.
If repairs are not made properly, the unit may leak water
and present a risk of electric shock, or it may produce smoke
or cause fire.
Securely attach the terminal cover(panel) on the unit.
If installed improperly, dust and/or water may enter the unit
and present a risk of electric shock, smoke or fire.
Only use refrigerant R410A as indicated on the unit when
installing or relocating the unit.
The use of any other refrigerant or an introduction of air into
the unit circuit may cause the unit to run an abnormal cycle
and abnormal cycle and cause the unit to burst.
In the event of a refrigerant gas leak, provide adequate
ventilation to the room.
If leaked refrigerant gas is exposed to a heat source, noxious
gases may form.
Do not touch the fins on the heat exchanger with bare hands,
for they are sharp and dangerous.
Do not try to defeat the safety features of the devices, and
do not change the settings.
Defeating the safety features on the unit such as the pressure
switch and temperature switch or using parts other than the
dealer or specialist may result in fire or explosion.
When installing the unit in a small room, safeguard against
hypoxia that results from leaked refrigerant reaching the
threshold level.
Consult the dealer for necessary measures to take.
When relocating the air conditioner, consult the dealer or
a specialist.
Improper installation may result in water leak, electric shock,
or fire.
After completing the service work, check for a refrigerant
gas leak.
If leaked gas refrigerant is exposed to a heat source such
as fan heater,stove,and electric grill, noxious gases may
form.
Only use specified parts.
Have the unit professionally installed. Improper installation
may cause water leak, electric shock,smoke, or fire.
With All-Fresh type air conditioners, outdoor air may be
directly blown into the room upon thermo off. Take this into
consideration when installing the unit.
Direct exposure to outdoor air may present a health hazard,
and it may also cause food items to deteriorate.
WARNING
WARNING
Safety Precautions
3
Precautions for Handling Units for Use with R410A
Do not use the existing refrigerant piping
The old refrigerant and refrigerator oil in the existing piping
contain a large amount of chlorine, which will cause the
refrigerator oil in the new unit to deteriorate.
R410A is a high-pressure refrigerant, and the use of the
existing piping may result in bursting.
Keep the inner and outer surfaces of the pipes clean and
free of contaminants such as sulfur, oxides, dust/dirt shaving
particles,oils,and moisture.
Contaminants inside the refrigerant piping will cause the
refrigerant oil to deteriorate.
Use a vacuum pump with a reverse-flow check valve.
If other types of valves are used, the vacuum pump oil will
flow back into the refrigerant cycle and cause the refrigerator
oil to deteriorate.
Do not use the following tools that have been used with the
conventional refrigerants. Prepare tools that are for exclusive
use with R410A.
(Gauge manifold, charging hose, gas leak detector,
reverse-flow check valve, refrigerant charge base,vacuum
gauge, and refrigerant recovery equipment.)
If refrigerant and/or refrigerant oil left on these tools are
mixed in with R410, or if water is mixed with R410A, it will
cause the refrigerant to deteriorate.
Since R410A does not contain chlorine, gas-leak detectors
for conventional refrigerators will not work.
Store the piping to be used during installation indoors, and
keep both ends of the piping sealed until immediately before
brazing.(keep elbows and other joints wrapped in plastic.)
If dust, dirt, or water enters the refrigerant cycle, it may
cause the oil in the unit to deteriorate or may cause the
compressor to malfunction.
A large amount of mineral oil will cause the refrigerating
machine oil to deteriorate.
Use a small amount of ester oil, ether oil, or alkylbenzene
to coat flares and flange connections.
Use liquid refrigerant to charge the system.
Charge the unit with gas refrigerant will cause the refrigerant
in the cylinder to change its composition and will lead to
a drop in performance
Do not use a charging cylinder.
The use of charging cylinder will change the composition
of the refrigerant and lead to power loss.
Exercise special care when handling the tools.
An introduction of foreign objects such as dust, dirt or
water into the refrigerant cycle will cause the refrigerating
machine oil to deteriorate.
Only use R410A refrigerant.
The use of refrigerants containing chlorine(i.e. R22) will
cause the refrigerant to deteriorate.
Before Installing the Unit
Do not install the unit in a place where there is a possibility
of flammable gas leak.
Leaked gas accumulated around the unit may start a fire.
Do not use the unit to preserve food, animals, plants, artifacts,
or for other special purposes.
The unit is not designed to provide adepuate conditions
to preserve the quality of these items.
Do not use the unit in an unusual environment
The use of the unit in the presence of a large amount of
oil, steam, acid, alkaline solvents or special types of sprays
may lead to a remarkable drop in performance and/or
malfunction and presents a risk of electric shock, smoke,
or fire.
The presence of organic solvents, corroded gas (such as
ammonia,sulfur compounds,and acid may cause gas or
water leak.)
When installing the unit in a hospital, take necessary measures
against noise.
High-frequency medical equipment may interfere with the
normal operation of the air conditioning unit or the air
conditioning unit may interfere with the normal operation
of the medical equipment
When humidity level exceeds 80% or when the drainage
system is clogged, indoor units may drip water.
Installation of a centralized drainage system for the outdoor
unit may also need to be considered to prevent water drips
from the outdoor units.
Do not place the unit on or over things that may not get wet.
Caution
Caution
Caution
Safety Precautions
4
Before Installing (Relocating) the Unit or Performing Electric Work
Ground the unit.
Do not connect the grounding on the unit to gas pipes,water
pipes, lightning rods, or the grounding terminals of
telephones. Improper grounding presents a risk of electric
shock, smoke, fire, or the noise caused by improper
grounding may cause the unit to malfunction.
Before the Test Run
Do not operate switches with wet hands to avoid electric.
Allow for at least five minutes before turning off the unit,
otherwise the unit may leak water or experience other
problems.
Do not turn off the power immediately after stopping the unit.
If the wires are too taut, they may break or generate heat
and/or smoke and cause fire.
Make sure the wires are not subject to tension.
Install a breaker for current leakage at the power source
to avoid the risk of electric shock.
Without a breaker for current leakage, there is a risk of
electric shock, smoke or fire.
Use breakers and fuses (electrical current breaker, remote
switch<switch+Type-B fuse>,molded case circuit breaker)
with a proper current capacity.
The use of large-capacity fuses, steel wire, or copper wire
may damage the unit or cause smoke or fire.
When installing draining pipes, follow the instructions in the
manual, and make sure that they properly drain water so as
to avoid dew condensation.
If not installed properly, they may cause water leaks and
damage the furnishings.
Do not spray water on the air conditioners or immerse the
air conditioners in water.
Water on the unit presents a risk of electric shock.
Periodically check the platform on which is placed for damage
to prevent the unit from falling.
If the unit is left on a damaged plarform, it may topple over,
causing injury.
Things such as nails may be included in the package.
Dispose of them properly to prevent injury.
Plastic bags present a choking hazard to children. Tear
up the plastic bags before disposing of them to prevent
accidents.
Properly dispose of the packing materials.
Do not touch the refrigerant pipes with bare hands during
and immediately after operation.
Depending on the state of the refrigerant in the system,
certain parts of the unit such as the pipes and compressor
may become very cold or hot and may subject the person
to frost bites or burning.
Do not operated the unit without panels and safety guards
in their proper places.
They are there to keep the users from injury from
accidentally touching rotating, high-tempreture or high-
voltage parts.
Dust particles in the air may clog the system and cause
malfunction.
Do not operate the unit without air filters.
Caution
Caution
Safety Precautions
5
Read Before Installation
Tools/Materials Use Notes
Gauge Manifold Evacuating,refrigerant charging 5.09MPa on the High-pressure side.
Charging Hose Evacuating, refrigerant charging Hose diameter larger than the concentional ones.
Refrigerant Recovery Equipment Refrigerant recovery
Refrigerant Cylinder Refrigerant charging Write down the refrigerant type. Pink in color at the top of the cylinder.
Refrigerant Cylinder Charging Port Refrigerant charging Hose diameter larger than the conventional ones.
Flare Nut Connecting the unit to piping Use Type-2 Flare nuts.
Tools/Materials Use Notes
Gas leak detector Detection of gas leaks The ones for HFC type refrigerant may be used.
Vacuum Pump Vacuum drying May be used if a reverse flow check adaptor is attached.
Refrigerant Recovery Equipment Recovery of refrigerant May be used if designed for use with R410A.
Flare Tool Flare machining of piping Chages have been made in the flare machining dimension.Refer to the next page.
Tools/Materials Use Notes
Vacuum Pump with a Check Valve Vacuum drying
Bender Bending pipes
Pipe Cutter Cutting pipes
Torque Wrench Tightening flare nuts Only 12.70 (1/2'') and 15.88(5/8'') have a larger flare machining dimension.
Welder and Nitrogen Cylinder Welding pipes
Refrigerant Charging Meter Refrigerant charging
Vacuum Gauze Checking vacuum degree
Tools/Materials Use Notes
Charging Cylinder Refrigerant Charging Must not be used with R410-type units.
CAUTION
Items to Be Checked
(1). Verify the type of refrigerant used by the unit to be serviced. Refrigerant Type: R410A
(2). Check the symptom exhibited by the unit to be serviced. Look in this service handbook for symptoms relating to the
refrigerant cycle.
(3). Be sure to carefully read the safety precautions at the beginning of this document.
(4). If there is a gas leak or if the remaining refrigerant is exposed to an open flame, a noxious gas hydrofluoric acid may
form. Keep workplace well ventilated.
Install new pipes immediately after removing old ones to keep moisture out of the refrigerant circuit.
Chloride in some types of refrigerants such as R22 will cause the refrigerating machine oil to deteriorate.
Necessary Tools and Materials
Prepare the following tools and materials necessary for installing and servicing the unit.
Necessary tools for use with R410A(Adaptability of tools that are for use with R22 and R407C).
1. To be used exclusively with R410A ( Not to be used if used with R22 or R407C )
2. Tools and materials that may be used with R410 with some restrictions
3. Tools and materials that are used with R22 or R407C that can also be used with R410A
4. Tool and materials that must not used with R410A
Tools for R410A must be handled with special care, and keep moisture and dust from entering the cycle.
6
Read Before Installation
Maximum Operation Pressure Applicable Refrigerants
3.4MPa R22, R407C
4.15MPa R410A
Use pipes that meet the local standards.
Use pipes made of phosphorus deoxidized copper.
Since the operation pressure of the units that use R410A is higher than that of the units for use with R22, use pipes with
at least the radial thickness specified in the chart below. (Pipes with a radial thickness of 0.7mm or less may not be used.)
Although it was possible to use type-O for pipes with a size of up to
19.05(3/4") with conventional refrigerants, use type-
1/2H pipes for units that use R410A.(Type-O pipes may be used if the pipe size is
19.05 and the radial thickness is 1.2t.)
The table shows the standards in Japan. Using this table as a reference, choose pipes that meet the local standards.
The flare machining dimensions for units that use R410A is larger than those for units that use R22 in order to increase
air tightness.
If a clutch type flare tool is used to machine flares on units that use R410A, make the protruding part of the pipe between
1.0 and 1.5mm. Copper pipe gauge for adjusting the length of pipe protrusion is useful.
Size(mm) Radial Thickness(mm)Size(inch)
Type
Type-O pipes
Type-1/2H or Hpipes
Piping Materials
Types of Copper Pipes (Reference)
The table shows the standards in Japan. Using this table as a reference, choose pipes that meet the local standards.
Piping Materials/Radial Thickness
Flare Machining (type-O and OL only)
Flare Machining Dimension(mm)
External dimension of pipes
Size
Dimension A
R410A R22
6.35
9.52
12.7
15.88
19.05
1/4"
3/8"
1/2"
5/8"
3/4"
9.1
13.2
16.6
19.7
24.0
9.0
13.0
16.2
19.4
23.3
Flare Nut
Type-2 flare nuts instead of type-1 nuts are used to increase the strength. The size of some of the flare nuts have also
been changed.
Flare nut dimension(mm)
R410A(Type2) R22(Type1)
6.35
9.52
12.7
15.88
19.05
1/4"
3/8"
1/2"
5/8"
3/4"
17.0
22.0
26.0
29.0
36.0
17.0
22.0
24.0
27.0
36.0
6.35
9.52
12.7
15.88
1/4''
3/8''
1/2''
5/8''
0.8t
0.8t
0.8t
1.0t
19.05 3/4'' 1.0t
Dimension A
External dimension of pipes Size
Dimension B
Dimension B
7
8
NO
Wind direction
Air outlet
Cushion rubber
4.Installation dimension(Unit:mm)
*
9
1U07BS1ERA
1U09BS1ERA
1U12BS1ERA
1U18FS1ERA
1U24GS1ERA
1.
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
A
B
Outdoor unit
Indoor unit
Oil trap
Tobend a pipe,givetheroundnessaslargeaspossiblenottocrushthepipe,
ƽ
andthebendingradiusshouldbe30to40
mm or longer.
Connecting the pipe of gas side first makes working easier.
ƽ
TheconnectionpipeisspecializedforR410A.ƽ
Half union
Flare nut
Torque wrench
CAUTION
Be careful that matters, such as wastes of sand
s,water,
,etc.shallnotenterthepipe.
ThestandardpipelengthisC m.IfitisoverDm,thefunctionoftheunitwillbeaffected.Ifthepipe
has
to be lengthened, the refrigerant should be charged,
according to E g/m. But the charge of refrigerant
must
beconductedbyprofes
sionalairconditionerengineer.Beforeaddingadditionalrefrigerant,
perform
air
purgingfromtherefrigerantpipesandindoorunitusing a vacuumpump,then
Spanner
Forced fastening without careful centering may
damagethethreadsandcause a leakageofgas.
Pipe Diameter(ǿ) Fastening torque
Liquid side6.35mm(1/4") 18N.m
Liquid/Gas side9.52mm(3/8") 42 N.m
Gasside12.7mm(1/2") 55N.m
Gasside15.88mm(5/8") 60N.m
Max.Elevation:
In case the elevation A is more
than 5m, oil trap shoud be
installed every 5~7
Max. Length:
In case the pipe length B is
more thanDm, the refrigerant
should be charged, according
to E g/m.
Connection of pipes
charge
additional refrigerant.
Amax
Bmax
2.
10
11
(e.g.1U18FS1ERA)
12
1U07BS1ERA
1U09BS1ERA
1U12BS1ERA
1U18FS1ERA
1U24GS1ERA
T 25A/250V.
3
2
^
1
)
(
N
)(
L
)(
C
3
2
1
)
(
N
)
(
L
)
(
C
To Indoor unit
1U07BS1ERA
1U09BS1ERA
1U12BS1ERA
1U18FS1ERA 1U24GS1ERA
Model
Connecting wiring
Power cable
3G2.5mm
2
3G4.0mm
2
3G1.5mm
2
4G0.75mm
2
4G0.75mm
2
4G0.75mm
2
N
(
1
3
)
)
C(L
(
2
)
{
L
N
POWER
Outdoor unit
To Indoor unit
Outdoor unit
POWER
FOR 07K 09K 12K
FOR 18K 24K
13
15
Outdoor Unit
2
9
15
8
12
10
5
13
19
1
18
4
11
6
25
25
25
110
Haier Group
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.ChiQD
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
Website: www.haier.com
Suction temperature sensor failure
When the The wiring of compressor is wrong or
the connection is poor
17
16
15
Lack of refrigerant
Check if there is leakage in the unit.
m
14
CONFORMIDAD DE LOS MODELOS
SEGÚN LAS NORMATIVAS EUROPEAS
CE
Todos los productos satisfacen los requisitos de las siguientes
normas europeas:
- Directiva de baja tensión, 73/23/CEE
- Directiva de baja tensión, 2006/95/CE
- Compatibilidad electromagnética 89/336/CEE
- Compatibilidad electromagnética 2004/108/CE
ROHS
Los productos satisfacen los requisitos de la directiva 2002/95/
CEE establecida por el Parlamento Europeo y el Consejo sobre
restricciones a la utilización de determinadas sustancias peligrosas
en aparatos eléctricos y electrónicos (Directiva RoHS UE).
WEEE
De acuerdo con la directiva 2002/96/CE del Parlamento Europeo,
se informa al consumidor acerca de los requisitos de eliminación
de productos eléctricos y electrónicos.
REQUISITOS DE ELIMINACIÓN:
Su aparato de aire acondicionado ha sido
marcado con este símbolo, el cual significa que
los productos de tipo eléctrico y electrónico
no deben mezclarse con residuos domésticos
sin clasificar. No intente desmontar el sistema
personalmente: tanto el desmontaje del sistema de aire
acondicionado como la manipulación del refrigerante, el
aceite y cualquier otro componente deben ser llevados
a cabo por un instalador capacitado, de acuerdo con la
legislación local y nacional al efecto. Los aparatos de aire
acondicionado deben ser manipulados en instalaciones de
manipulación especializadas y aptas para su reutilización,
reciclado y recuperación. Al garantizar la correcta
eliminación de este producto, usted contribuirá a evitar las
posibles consecuencias negativas que podría provocar
sobre el medioambiente y la salud humana. Póngase en
contacto con el instalador o la autoridad local pertinente
si desea obtener más información. Las pilas deben ser
extraídas del mando a distancia y eliminadas de forma
independiente, de acuerdo con la legislación local y nacional
al efecto.
INFORMACIÓN IMPORTANTE ACER-
CA DEL REFRIGERANTE UTILIZADO
1
1+2=
kg
R410A
2
kg
2=
1=
B
C
D
FE
kg
A
Este producto contiene gases fluorados de efecto invernadero
regulados por el Protocolo de Kioto. No los libere libremente a la
atmósfera.
Tipo de refrigerante: R410A
Valor GWP*: 1975
GWP = Potencial de contribución al calentamiento global
Escriba con tinta indeleble:
• 1 la carga de refrigerante que contiene el producto de fábrica
• 2 la cantidad de refrigerante adicional cargada durante la
instalación y
• 1+2 la carga total de refrigerante
en la etiqueta de carga de refrigerante suministrada con el
producto.
Una vez escritos los datos correspondientes, la etiqueta deberá
adherirse cerca de la conexión de carga del producto (por ejemplo,
sobre la parte interna de la cubierta de la válvula de retención).
A Contiene gases fluorados de efecto invernadero regulados por el
Protocolo de Kioto.
B Carga de refrigerante que contiene el producto de fábrica:
consulte la placa de características de la unidad.
C Cantidad de refrigerante adicional cargada durante la instalación.
D Carga total de refrigerante.
E Unidad exterior.
F Botella de refrigerante y colector de carga.
Contiene gases fluorados de efecto invernadero
regulados por el Protocolo de Kioto.
Haier Industrial Park, No.1 Haier Road, Qingdao, República Popular China
F
A
C
E
D
A
F
C
E
D
G
B
G
4
Dibujos de instalación de las unidades interior y exterior
Los modelos cumplen la norma R410A sobre refrigerantes libres de HFC.
Para obtener información sobre la instalación de las unidades interiores, consulte el manual de instalación proporcionado
con las mismas.
(El diagrama muestra una unidad interior montada en pared.)
La imagen anterior de las unidades interior y exterior solamente sirve de referencia.
Remítase al producto real adquirido.
más de 15 cm
Debe prestarse atención
a la pendiente del
manguito de drenaje
Organización de la
dirección de los tubos
Izquierda
Izquierda trasera
Derecha
trasera
Derecha
Inferior
más de
10 cm
más de 10 cm
más de
20 cm
más de 60 cm
Fijación de la unidad exterior
Fije la unidad a un bloque de
cemento con pernos (10 mm) y
tuercas firme y horizontalmente.
Si instala la unidad sobre una
pared, techo o tejado, instale un
soporte con clavos o cables consi-
derando la posibilidad de terremo-
tos o viento fuerte.
Si la vibración afectase a la casa,
fije la unidad instalando una alfom-
bra de absorción de vibraciones.
Las marcas comprendidas
entre
A
y
G
en la
ilustración corresponden
a los números de las
piezas.
La distancia entre la
unidad interior y el suelo
debe ser superior a 2 m.
Componentes opcionales para
la instalación de los tubos
Cinta no adhesiva
Cinta adhesiva
Soporte (L.S) con tornillos
Conexión de cable eléctrico para inte-
rior y exterior
Manguito de drenaje
Material aislante de calor
Cubierta
de orificio de entubación
más de 20 cm
más de 25 cm
Compresor (dentro de la unidad)
SALIDA DE AIRE
ENTRADA DE AIRE
TUBOS DE CONEXIÓN Y CABLEADO ELÉCTRICO
4 MANGUITO DE DRENAJE
15
Precauciones de seguridad
Lea detenidamente la siguiente información para poner en funcionamiento el aire acondicionado de forma correcta.
A continuación se enumeran tres tipos de precauciones de seguridad y sugerencias.
ADVERTENCIA Si realiza operaciones de forma incorrecta, pueden producirse graves consecuencias, como
la muerte o graves lesiones.
PRECAUCIÓN Si realiza operaciones de forma incorrecta, pueden producirse lesiones o daños en la
máquina; en algunos casos pueden producirse graves consecuencias.
INSTRUCCIÓN: Esta información puede asegurar el correcto funcionamiento de la máquina.
Símbolos utilizados en las ilustraciones
: indica una acción que se debe evitar.
: indica que es obligatorio seguir las instrucciones importantes.
: indica un componente que se debe conectar a tierra.
: atención a las descargas eléctricas (este símbolo se muestra en la etiqueta de la unidad principal.)
Después de leer este manual, entréguesela a aquellas personas que utilicen a la unidad.
El usuario de esta unidad debe tener este manual a mano y ponerlo a disposición de quienes repararán o reubicarán la unidad. Asimismo,
debe ponerlo a disposición de los nuevos usuarios cuando el producto cambio de manos.
Asegúrese de seguir estas importantes precauciones de seguridad.
ADVERTENCIA
Si se producen fenómenos anormales
(por ejemplo, olor a quemado), corte la
fuente de alimentación inmediatamente,
y póngase en contacto con el distribuidor
para averiguar el método de manipulación.
En dicho caso, si sigue utilizando el aire acondicionado, éste
resultará dañado, y pueden producirse descargas eléctricas o
peligro de incendio.
Tras un largo período de tiempo sin utilizar
el aparato de aire acondicionado, debe
comprobar la base para ver si se han pro-
ducido daños.
Si la base dañada no se repara, es posible
que la unidad se caiga y provoque acci-
dentes.
● No desmonte la boca de salida de la
unidad exterior.
La exposición del ventilador es muy peli-
grosa, ya que puede provocar lesiones
en las personas.
Cuando necesite mantenimiento y repa-
ración, llame al distribuidor para gestio-
narlo.
Si el mantenimiento y la reparación se
realizan de forma incorrecta podrían
producirse fugas de agua, descargas
eléctricas y peligro de incendio.
Desactivar
ADVERTENCIA
No se pueden colocar cosas o personas
sobre la unidad exterior. La caída de cosas o
personas puede provocar accidentes.
No ponga en funcionamiento el aire acon-
dicionado con las manos mojadas. De lo con-
trario, se producirán descargas eléctricas.
Utilice sólo fusibles del tipo correcto.
No se puede utilizar ningún cable ni otro ma-
terial que sustituya al fusible, de lo contrario,
se producirán fallos o incendio.
Utilice el tubo de descarga correctamente
para asegurar la eficacia de la descarga.
Si utiliza el tubo de forma incorrecta podrían
producirse fugas de agua.
Interruptor de circuito de fugas eléctricas instalado.
Provoca descargas eléctricas con facilidad sin el interruptor de
circuito.
El aire acondicionado no puede instalarse en lugares con gases
inflamables, ya que podrían provocar peligro de incendio.
El distribuidor es el responsable de la instalación del aparato de
aire acondicionado. Si la instalación se realiza de forma incor-
recta podrían producirse fugas de agua, descargas eléctricas y
peligro de incendio.
Llame al distribuidor para tomar medidas que eviten fugas de
refrigerante.
Si el aparato de aire acondicionado está instalado en una habita-
ción pequeña, asegúrese de tomar las medidas necesarias para
evitar
asfixia, incluso en caso de fuga de refrigerante.
Cuando el aire acondicionado se instala o se vuelve a instalar, el
distribuidor en el responsable de dichas tareas.
Si la instalación se realiza de forma incorrecta podrían producir-
se fugas de agua, descargas eléctricas y peligro de incendio.
Conecte el cable de conexión a tierra.
El cable de conexión a tierra no debe conectarse al
tubo de gas, tubo de agua, barra pararrayos o línea
telefónica. Si la conexión a tierra se realiza de manera
incorrecta, podrían producirse descargas.
Puesta a
tierra
16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Haier 1U09BS1ERA Guida d'installazione

Categoria
Condizionatori d'aria a sistema split
Tipo
Guida d'installazione
Questo manuale è adatto anche per