Davey DSF3003FCE Istruzioni per l'uso

Tipo
Istruzioni per l'uso

Questo manuale è adatto anche per

Please pass these instructions on to the operator of this equipment.
The installation of this product should be carried out by a person knowledgeable
in swimming pool plumbing requirements following the installation instructions
provided in this manual.
Please install and maintain the products according to EN 60335-2-41 standard
and local standard when the product is used in Europe.
WARNING: Failure to follow these instructions and comply with all
applicable codes may cause serious bodily injury and/or property damage.
ENGLISH
7 LANGUAGES
English, Deutsch, Italiano,
Nederlands, Português,
Espol & Fraais
Single & 3 Phase Models
Installation and Operating
Instructions
Star
Flo
®
2
Prior to using this pump you must ensure that:
The pump is installed in a safe environment
The pump enclosure has adequate drainage in the event of leakage
The pipe-work is correctly sealed and supported
The pump is primed correctly
The power supply is correctly connected
All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation and
Operating Instructions. Read these in their entirety before switching on this pump. If you
are uncertain as to any of these Installation and Operating Instructions please contact your
Davey Dealer or the appropriate Davey ofce as listed on the back of this document.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualied persons in order to avoid a hazard.
Your Davey StarFlo Pool Pump
Congratulations on your purchase of a quality product from the Davey range of Pool
equipment. You are assured of many years of reliable and efcient performance from your
Davey StarFlo pool pump backed by Davey’s two year guarantee.
The Davey StarFlo pool pump has been designed to circulate swimming pool water in
conditions set out in the Australian Standard for swimming pool water quality (AS 3633)
or equivalent. They should not be used for any other purpose without rst consulting your
Davey Dealer or the Davey Customer Service Centre.
Every Davey StarFlo pool pump is thoroughly tested against a number of pressures, voltage,
current and mechanical performance parameters. Davey’s advanced pump manufacturing
technology provides reliable and efcient pumping performance that lasts and lasts.
Power supply to this pump needs to be through an isolating transformer
or RCD, having a rated operating current not exceeding 30mA.
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE
AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES
OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE
WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY
WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE MADE
BY CHILDREN WITHOUT SUPERVISION.
DO NOT DISPOSE OF ELECTRICAL APPLIANCES AS UNSORTED MUNICIPAL
WASTE, USE SEPARATE COLLECTION FACILITIES.
CONTACT YOUR LOCAL GOVERNMENT FOR INFORMATION REGARDING THE
COLLECTION SYSTEMS AVAILABLE.
IF ELECTRICAL APPLIANCES ARE DISPOSED OF IN LANDFILLS OR DUMPS,
HAZARDOUS SUBSTANCES CAN LEAK INTO THE GROUNDWATER AND GET INTO
THE FOOD CHAIN, DAMAGING YOUR HEALTH AND WELL-BEING.
ENGLISH
3
Davey StarFlo Pool Pump – Hydraulic Performance:
TOTAL HEAD (m)
FLOW (m
3
/hr)
FLOW (lpm)
27
0 6 12 18 24 30
0
0 100 200 300 400 500
0
3
6
9
12
15
18
21
24
DSF420(CE)
DSF300(CE)
DSF150(CE)
DSF200(CE)
DSF250(CE)
TOTAL HEAD (m)
27
0 6 12 18 24 30
0
3
6
9
12
15
18
21
24
DSF4203F(CE)
DSF3003F(CE)
FLOW (m
3
/hr)
FLOW (lpm)
0 100 200 300 400 500
0
Model
QMAX
H
MAX
(m)
Power (P
1
) Power (P
2
)
Amps
Net Weight
(kg)
L/min m
3
/hr
kW HP kW HP
DSF150(CE)* 300 18 10 0.55 0.75 0.37 0.5 2.6 12.4
DSF200(CE) 333 20 13 0.75 1.0 0.55 0.75 3.7 13.6
DSF250(CE) 400 24 14 0.87 1.2 0.57 0.78 3.8 14.6
DSF300(CE) 433 26 18 1.1 1.5 0.75 1.0 5.8 15.5
DSF420(CE) 483 30 20 1.65 2.2 1.3 1.7 8.3 17.6
DSF3003F(CE) 383 24 17 1.1 1.5 0.75 1.0 2.0 14.3
DSF4203F(CE) 483 31 20 1.65 2.2 1.3 1.7 3.2 16.5
*Please note: DSF150(CE) is self priming at 2m maximum.
ENGLISH
ENGLISH
4
Location
The pump should be located as close to the water as practicable and mounted on a rm
base in a well-drained position, high enough to prevent any ooding. It is the installer’s
responsibility to locate the pump such that the nameplate can be easily read and it can
be readily accessed for service. The two holes in the base shall be xed on the ground
(alternatively, this can be with a rubber pad and/or mounting frame) after installing the pump.
Weather Protection
It is recommended that the pump is protected from the weather.
Power Connection
IMPORTANT INFORMATION: If equipotential bonding structure is required, then a
Equipotential Bonding Point is provided. (Please refer to your local wiring standard
and regulations).
Davey StarFlo DSF150CE, DSF200CE, DSF250CE, DSF300CE and DSF420CE pool pumps
are suitable for connection to a nominal 220-240 volt 50Hz power supply and are equipped
with a ex lead. If a power outlet is not available within 3 metres of the pump, a power point in
a safe, dry place may need to be provided by an electrician/electrical contractor.
Davey StarFlo DSF3003FCE and DSF4203FCE pool pumps are suitable for connection
to a nominal 380-415 volt 50Hz power supply and are equipped with a ex lead. Power
connection needs to be provided by an electrician/electrical contractor.
Davey StarFlo DSF150, DSF200, DSF250, DSF300 and DSF420 pool pumps are suitable for
connection to a nominal 220-240 volt 50Hz power supply and are equipped with a ex lead
and 3 pin plug. If a power outlet is not available within 3 metres of the pump, a 3 pin power
point in a safe, dry place may need to be provided by an electrician/electrical contractor.
Extension cords are unsafe around pools – and should be avoided. If the supply cord
of this product is damaged it must be replaced by the Dealer or distributor, with genuine
Davey spares.
ATTENTION: Davey Water Products recommends that all installations are
tted with earth leakage or residual current protection devices. Power supply
to this pump needs to be through an isolating transformer or RCD, having
a rated operating current not exceeding 30mA. In the interests of safety, we
advise that the installation must be in accordance with AS3000 wiring rules,
or local equivalent. Ensure that an electrical isolation switch be located
within easy access so that the pump can be turned off in an emergency.
ATTENTION: In accordance with AS/NZS 60335.2.41 we are obliged to inform
you that this pump is not to be used by children or inrm persons and must not
be used as a toy by children. If the pump and lter are located below pool water
level, it is necessary to t isolating valves in the pipe between the pump and the
skimmer box and in the return pipe between the pump and the lter.
IMPORTANT: The ttings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability before use.
ENGLISH
5
Typical installation diagram
Water pump
Sand filter
Vacuum hose Vacuum head
Dimensions
Pipe Connection
The StarFlo pool pumps are supplied with barrel unions for connecting to the piping from
the pool. The following models are designed to accept European 50 & 63mm PVC pipe:
* DSF150(CE) * DSF420(CE)
* DSF200(CE) * DSF3003F(CE)
* DSF250(CE) * DSF4203F(CE)
* DSF300(CE)
The following models are designed to 40mm & 50mm nominal PVC pipe:
* DSF150 * DSF420
* DSF200 * DSF3003F
* DSF250 * DSF4203F
* DSF300
The use of any pipe smaller than those specied above is not recommended. Suction
piping should be free from all air leaks and any humps and hollows which cause suction
difculties. The discharge piping from the pump outlet should be connected to the inlet
connection on the swimming pool lter (usually at the lter control valve).
IMPORTANT: Barrel unions need to be hand tightened. No sealant, glues
or silicones are required.
ENGLISH
ENGLISH
6
Starting the Pump
To operate efciently and prevent pump damage there must be a free ow of water to and
from the pump. Before starting ensure that:
All pipework is correctly sealed.
The pool water level is at the correct height.
Ensure that all appropriate valves are open and there is nothing preventing the ow of
water through the system.
1. When the pump is above the pool water line, rst prime the pump by removing the
strainer basket lid and lling the strainer basket area with water. Replace the lid,
ensuring that it seals on the o-ring.
2. Connect to the power supply and turn on.
3. Allow the pump to run, so that any air trapped may be expelled.
4. If prime is not established within approximately two minutes, as evidenced by a strong
ow of water, turn off the pump and repeat the procedure. Continued evidence of air
under the strainer basket lid indicates an air leak in the suction piping which should be
rectied to avoid pump damage.
Pump Operation
For optimum pump performance, the strainer basket housing should always be full of water
and free from air bubbles. The water level of the pool should always be maintained to at least
halfway up the skimmer box ensuring water is in the pump at all times. From time to time it
may be necessary to re-prime the pump. This should be carried out as described above.
Never run pump dry. Running the pump with no water may damage the
mechanical seals, causing leakage and ooding. Dry running damage
and associated damage is not covered under warranty. Davey StarFlo
pool pumps incorporate self-resetting thermal overload, reducing
potential damage.
ENGLISH
7
Emptying the Strainer Basket
The strainer basket should be inspected frequently through the transparent lid and emptied
when a buildup of rubbish is evident. The directions below should be followed.
1. Turn off pump and unplug.
2. Close all valves in pipework.
3. Unscrew the strainer basket lid anti-clockwise and remove.
4. Remove the strainer basket by lifting upwards from its housing.
5. Empty the trapped refuse from the basket. Hose out with water if necessary.
6. Check the strainer basket for cracks, replace the strainer basket in the pump if ok.
Failure to undertake regular maintenance may cause damage not covered by warranty.
7. Replace the lid and ensure that it seals on the rubber o-ring. Firm hand tightness only is
required. The o-ring & thread can be lubricated with Hydra slip or equivalent products.
8. Open all valves in pipework.
IMPORTANT: Failure to undertake regular maintenance may cause damage
not covered by warranty.
ENGLISH
ENGLISH
8
Trouble Shooting
If the pump runs but there is no water ow or water ow is reduced, the following
condition may apply:
1. The lter requires backwashing or it is blocked. Refer to the relevant section in the
Filter Manual.
2. The pump is not primed. Re-prime as per instruction in ‘Starting the pump’
3. There are air leaks in the suction piping. Check all piping and eliminate leaks, also check
for a loose strainer basket lid. Air bubbles in the water owing back to the pool would
indicate a leak in the suction to the pump allowing air to enter the pipework.
4. A leaking pump shaft seal may also prevent operating. Evidence of this would be water
on the ground under the pump.
5. The pump is not able to get water from the pool. Check that the valves to the pump are
fully open and that the pool water level is halfway up to the skimmer box.
6. Blockage in the piping or pump. Remove the strainer basket and check for any blockage
to the pump impeller entry. Check the skimmer box for blockage.
If the pump does not operate, the following conditions may apply:
1. The power is not connected. For 220-240 volt only, check the power point by plugging in
a portable appliance to ensure power is available. Also check fuses and the main power
supply switch.
2. Automatic overload is tripped following an overheating period. The pump has an in-built
thermal overload which will re-set after the motor has cooled. Determine the cause of the
overload tripping and rectify.
3. Blockage is preventing the pump from rotating.
4. Motor is burnt out – burning smell is evident. Replacement is required.
If you are unable to resolve any installation or operation difculties with your Davey StarFlo pool
pump, contact the supplier from whom the pump was purchased. If any further assistance is
required, contact your Davey representative at the address indicated at the end of this manual.
The repair, removal and maintenance of the appliance shall be carried out by the
manufacturer or the professional personnel of the agent.
ENGLISH
9
Removal of the Pump from Pipework
Should it be necessary to remove the pump, follow these instructions:
1. Turn off the power and remove the plug from the power source.
ATTENTION: If the pump is wired into a time clock, or another
automatic control the wiring may need to be removed by a qualied
electrical contractor. If you are unsure, contact the place you’ve
purchased the product, or if further assistance is required, contact
your Davey representative at the address indicated in this manual.
2. Close the water valves on the pool return and the pump inlet pipework.
3. Remove the discharge & suction barrel unions taking care not to lose the O-rings.
4. Move the pipework with the barrel unions attached until the pump can be pulled clear.
NOTE: When making any enquiries about your StarFlo pool pump be
certain to quote the model number from the nameplate located on motor.
Water Quality
Maintaining balanced water chemistry is important to the life of your pool pump. This pump is
designed to be used with Pool water, balanced in accordance with Langlier Saturation Index.
POOL WATER
BALANCE
Free Chlorine
(ppm)
pH
Total
Alkalinity TA
(ppm)
Calcium
Hardness
(ppm)
Stabiliser -
Cyanuric Acid
(ppm)
Ideal
reading
/ range
1.5 - 3
Concrete &
tiled pools
7.4-7.6
Other surfaces
7.2-7.4
80 - 150
Concrete &
tiled pools
200-275
Other surfaces
100-225
25-50ppm
(15-25ppm if used
with an ORP
controller)
Not to be used in
indoor pools.
To increase
Increase
output of
sanitiser.
Add chlorine.
Increase
ltration time.
Add Soda
Ash (Sodium
Carbonate)
Add Buffer
(Sodium
Bicarbonate)
Add Calcium
Chloride
Add Cyanuric
Acid
To decrease
Decrease output
of sanitiser.
Decrease
ltration time.
Add
Hydrochloric
Acid
Add
Hydrochloric
Acid or Dry
Acid
Partially drain
& rell pool
with lower
hardness
water to dilute
Partially drain
& rell pool to
dilute
Frequency
of testing
Weekly Weekly Weekly Weekly Regularly
Please consult your local pool shop regularly to have your water tested.
ENGLISH
ENGLISH
10
POWER CONNECTIONS AND WIRING MUST BE CARRIED OUT BY
AN AUTHORISED ELECTRICIAN.
WARNING! Pump suction is hazardous and can trap and drown or
disembowel bathers. Do not block suction. Do not use or operate
swimming pools if a suction cover is broken, missing or loose. Two
suction covers and inlets must be provided into every pump to avoid
suction entrapment.
Caution! Do not add chemicals directly to the pool skimmer. Adding
undiluted chemicals may damage pump and lter and void warranty.
Routine Maintenance tasks – to maximise the life of your pool equipment
& personal safety, use this checklist once a week. Turn pump off rst.
a. Make sure that any pressure gauges are in working condition and the
operating pressure is within limits as specied on the product.
b. Make sure that each suction inlet, and main drain has a cover that is
securely attached and in safe working condition.
c. Make sure that all skimmer covers are securely attached and in safe working
condition. These should be replaced every 3 to 4 years.
d. Remove any obstructions or debris from the main drain cover.
e. Ensure the skimmer baskets and the pump hair and lint pots are free of
leaves and debris at least once a week.
f. Remove obstructions and combustibles from around the pump motor.
g. Make sure all wiring connections are clean and that all wiring and electrical
equipment is in good condition. Damaged wiring must be repaired or
replaced by a qualied electrician as soon as damage is discovered.
h. Check water balance and sanitiser levels at your local pool shop.
i. Check for sufcient air-ow behind pump – clearance.
DANGER – Hazardous suction. Do not block water entry into ltration
system with any part of your body as the pressure can trap hair or body
parts, causing severe injury or death. Do not block suction.
Turn off pump immediately if someone becomes trapped.
ENGLISH
11
ENGLISH
ENGLISH
NOTES
® Davey is a trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2020.
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NORTH AMERICA
Ph: 1-877-885-0585
AUSTRALIA
Head Offi ce
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 232 839
Fax: 1300 369 119
Email: sales@davey.com.au
daveywater.com
NEW ZEALAND
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 0800 654 334
EUROPE
ZAC des Gaulnes
355 Avenue Henri Schneider
69330 Meyzieu, France
Ph: +33 (0) 4 72 13 95 07
Fax: +33 (0) 4 72 33 64 57
Email: info@daveyeurope.eu
MIDDLE EAST
Ph: +971 50 6368764
Fax: +971 6 5730472
P/N 403189-4UK
ENGLISH
Davey pump warranty
Davey Water Products Pty Ltd (Davey) warrants all products sold will be (under normal use and service) free of defects in
material and workmanship for a minimum period of one (1) year from the date of original purchase by the customer as marked
on the invoice, for specic warranty periods for all Davey products visit daveywater.com.
This warranty does not cover normal wear and tear or apply to a product that has:
been subject to misuse, neglect, negligence, damage or accident
been used, operated or maintained other than in accordance with Davey’s instructions
not been installed in accordance with the Installation Instructions or by suitably qualied personnel
been modied or altered from original specications or in any way not approved by Davey
had repairs attempted or made by other than Davey or its authorised dealers
been subject to abnormal conditions such as incorrect voltage supply, lightning or high voltage spikes, or damages from
electrolytic action, cavitation, sand, corrosive, saline or abrasive liquids,
The Davey warranty does not cover replacement of any product consumables or defects in products and components that
have been supplied to Davey by third parties (however Davey will provide reasonable assistance to obtain the benet of any
third-party warranty).
To make a warranty claim:
If the product is suspected of being defective, stop using it and contact the original place of purchase. Alternatively, phone
Davey Customer Service or send a letter to Davey as per the contact details below
Provide evidence or proof of date of original purchase
If requested, return the product and/or provide further information with respect to the claim. Returning the product to the
place of purchase is at your cost and is your responsibility.
The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will
be accepted if:
o a relevant defect is found
o the warranty claim is made during the relevant warranty period; and
o none of the excluded conditions listed above apply
The customer will be notied of the warranty decision in writing and if found to be invalid the customer must organise
collection of the product at their expense or authorise its disposal.
If the claim is found to be valid Davey will, at its option, repair or replace the product free of charge.
The Davey warranty is in addition to rights provided by local consumer law. You are entitled to a replacement or refund for a
major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
For any internet connected products the consumer is responsible for ensuring a stable internet connection. In the event of a
network failure the consumer will need to address the concern with the service provider. Use of an App is not a substitute for
the Users own vigilance in ensuring the product is working to expectation. Use of a Smart Product App is at the Users own
risk. To the fullest extent permitted by law Davey disclaims any warranties regarding the accuracy, completeness or reliability
of App data. Davey is not responsible for any direct or indirect loss, damage or costs to the User arising from its reliance on
internet connectivity. The User indemnies Davey against any claims or legal actions from them or others relying on internet
connectivity or App data may bring in this regard.
Products presented for repair may be replaced by refurbished products of the same type rather than being repaired.
Refurbished parts may be used to repair the products. The repair of your products may result in the loss of any user-generated
data. Please ensure that you have made a copy of any data saved on your products.
To the fullest extent permitted by law or statute, Davey shall not be liable for any loss of prots or any consequential, indirect
or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does
not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under local
laws and does not aect any rights or remedies that may be available to you under local laws.
For a complete list of Davey Dealers visit our website (daveywater.com) or call:
Geben Sie diese Anleitungen an den Betreiber dieser Anlage weiter.
Die Installation dieses Produkts sollte von einem kompetenten Schwimmbad-
Installateur und gemäß den Installationsanleitungen in diesem Handbuch
vorgenommen werden.
Wenn das Produkt in Europa genutzt wird, muss es gemäß der Norm EN 60335-2-
41 und den örtlich geltenden Vorschriften zu installieren und instandzuhalten.
WARNUNG: Die Nichteinhaltung dieser Anleitungen und jeglicher in diesem
Zusammenhang geltenden Vorschriften kann schwerwiegende Personen-
und/oder Sachschäden nach sich ziehen.
GERMAN
ENGLISH
Einphasige und dreiphasige Modelle
Installations- und
Betriebsanleitung
Star
Flo
®
14
Vor dem Gebrauch dieser Pumpe ist Folgendes sicherzustellen:
Die Pumpe sollte in einer sicheren Umgebung installiert sein.
Der Pumpenraum sollte für den Fall einer Undichtigkeit über ein geeignetes
Abusssystem verfügen.
Die Rohrleitungen müssen sachgerecht abgedichtet und abgestützt sein.
Die Pumpe muss sachgemäß entlüftet werden.
Die Netzversorgung sollte richtig angeschlossen sein.
Es sind alle Vorkehrungen für einen sicheren Betrieb zu treffen.
Entsprechende Ausführungen zu all diesen Punkten sind in der nachstehenden
Installations- und Betriebsanleitung dargelegt. Lesen Sie diese vollständig durch, bevor
Sie die Pumpe in Betrieb setzen. Bei Unsicherheiten bezüglich dieser Installations- und
Betriebsanleitung wenden Sie sich bitte an Ihren Davey Fachhändler oder an Ihre jeweilige
Davey Niederlassung, die auf der Rückseite dieses Handbuchs angegeben ist.
Wenn das Netzkabel beschädigt ist, muss es vom Hersteller, seiner Servicestelle oder
ähnlich qualizierten Fachleuten ausgewechselt werden, um Gefahren zu vermeiden.
Ihre Davey StarFlo Schwimmbadpumpe
Herzlichen Glückwunsch für Ihren Erwerb eines Qualitätsprodukts aus der Davey
Schwimmbad-Ausstattungsreihe. Ihre Davey StarFlo Schwimmbadpumpe mit der zweijährigen
Garantie von Davey bietet Ihnen eine langjährig zuverlässige und efziente Leistung.
Die Davey StarFlo wurde entwickelt, um das Wasser in Pool oder Spa zirkulieren zu
lassen gemäß der Vorgaben des Australischen Standards für Poolwasserqualität AS
3633 oder entsprechender anderer Vorgaben. Sie sollte nicht zu anderen Zwecken
verwendet werden, ohne dass Sie sich zuvor von Ihren Davey- Händler oder dem Davey-
Kundenzentrum haben beraten lassen.
Jede Davey StarFlo Schwimmbadpumpe wurde bezüglich der verschiedenen Druck-,
Spannungs-, Strom- und mechanischen Leistungsparameter eingehend geprüft. Die
fortschrittliche Produktionstechnologie von Davey bietet eine langjährig zuverlässige und
efziente Pumpenleistung.
Die Netzspeisung dieser Pumpe muss über einen Trenntransformator oder
eine Fehlerstromschutzeinrichtung mit einem Nennbetriebsstrom von
maximal 30 mA erfolgen.
DIESES GERÄT DARF VON KINDERN AB EINEM ALTER VON 8 JAHREN UND PERSONEN
MIT EINGESCHRÄNKTEN KÖRPERLICHEN, SENSORISCHEN BZW. GEISTIGEN
FÄHIGKEITEN, MANGELNDER ERFAHRUNG BZW. FEHLENDEM WISSEN GENUTZT
WERDEN, SOFERN SIE BEAUFSICHTIGT UND BEZÜGLICH DER SICHEREN NUTZUNG
DES GERÄTS AUFGEKLÄRT WERDEN UND SICH DER DAMIT VERBUNDENEN GEFAHREN
BEWUSST SIND. KINDER DÜRFEN NICHT MIT DEM GERÄT SPIELEN. REINIGUNGS- UND
INSTANDHALTUNGSARBEITEN DÜRFEN NICHT VON KINDERN OHNE BEAUFSICHTIGUNG
DURCHGEFÜHRT WERDEN.
ELEKTROGERÄTE DÜRFEN NICHT ALS UNSORTIERTER HAUSMÜLL ENTSORGT WERDEN,
SONDERN MÜSSEN ZUR ENTSORGUNG ALS SONDERMÜLL ZUR SAMMELSTELLE
GEBRACHT WERDEN.
WENDEN SIE SICH AN IHRE ÖRTLICHEN BEHÖRDEN, UM INFORMATIONEN BEZÜGLICH
DER VERFÜGBAREN ENTSORGUNGSMÖGLICHKEITEN EINZUHOLEN.
WENN ELEKTROGERÄTE IN DEPONIEN ENTSORGT WERDEN, KÖNNEN GEFÄHRLICHE
SUBSTANZEN IN DAS GRUNDWASSER ABFLIESSEN, IN DIE NAHRUNGSKETTE GELANGEN
UND SOMIT IHRE GESUNDHEIT UND IHR WOHLBEFINDEN BEEINTRÄCHTIGEN.
GERMAN
15
Davey StarFlo Schwimmbadpumpe – Hydraulische Leistung:
FÖRDERHÖHE (m)
FÖRDERMENGE (m
3
/hr)
27
0 6 12 18 24 30
0
3
6
9
12
15
18
21
24
DSF420(CE)
DSF300(CE)
DSF150(CE)
DSF200(CE)
DSF250(CE)
FÖRDERHÖHE (m)
FÖRDERMENGE (m
3
/hr)
27
0 6 12 18 24 30
0
3
6
9
12
15
18
21
24
DSF4203F(CE)
DSF3003F(CE)
Model
QMAX
H
MAX
(m)
Power (P
1
) Power (P
2
)
Amps
Net Weight
(kg)
L/min m
3
/hr
kW HP kW HP
DSF150(CE)* 300 18 10 0.55 0.75 0.37 0.5 2.6 12.4
DSF200(CE) 333 20 13 0.75 1.0 0.55 0.75 3.7 13.6
DSF250(CE) 400 24 14 0.87 1.2 0.57 0.78 3.8 14.6
DSF300(CE) 433 26 18 1.1 1.5 0.75 1.0 5.8 15.5
DSF420(CE) 483 30 20 1.65 2.2 1.3 1.7 8.3 17.6
DSF3003F(CE) 383 24 17 1.1 1.5 0.75 1.0 2.0 14.3
DSF4203F(CE) 483 31 20 1.65 2.2 1.3 1.7 3.2 16.5
*Bitte beachten Sie: Die DSF150CE Pumpe ist selbstansaugend bei 2m maximal
GERMAN
GERMAN
16
Installationsort
Die Pumpe sollte möglichst nahe am Wasser, auf festem, trockenem Untergrund und
zur Vermeidung jeglicher Überutung in einer ausreichend hohen Position installiert
werden. Es liegt in der Verantwortung des Installateurs, die Pumpe so einzubauen, dass
das Typenschild für den Wartungstechniker leicht zugänglich und ablesbar ist. Die zwei
Bohrungen in der Basis dienen zur Befestigung der Pumpe auf dem Untergrund.
(Alternativ dazu kann die Pumpe auf einer Gummiunterlage und/oder einem
Montagerahmen installiert werden.)
Wetterschutz
Es empehlt sich, die Pumpe wettergeschützt zu installieren.
Netzversorgungsanschluss
WICHTIGE INFORMATION: Ihre Davey Pumpe verfügt über einen doppelt isolierten
Wasserkreislauf. Wenn eine Potentialausgleichsvorrichtung erforderlich ist, wird ein
Potentialausgleichs-Punkt mitgeliefert. (Konsultieren Sie dazu Ihre örtlichen
Verdrahtungsnormen und -vorschriften).
Davey StarFlo Schwimmbadpumpen DSF150CE, DSF200CE, DSF250CE, DSF300CE
and DSF420CE sind für den Anschluss an eine Versorgungs-Nennspannung von 220-240
Volt / 50Hz vorgesehen und mit einem exiblen Anschlusskabel ausgestattet. Wenn für die
Pumpe in einem Umkreis von 3 Metern kein Spannungsanschluss verfügbar ist, muss der
Elektriker an einem sicheren, trockenen Ort einen Spannungsanschluss installieren.
Davey StarFlo DSF3003FCE und DSF4203FCE Poolpumpen sind für den Anschluss
an Stromnetze mit einer Nennspannung von 380-415 Volt 50Hz geeignet und mit
einem Netzkabel ausgestattet. Der Stromanschluss muss durch einen Elektriker bzw.
Elektroinstallationsbetrieb vorgenommen werden. Verlängerungskabel sind in der Nähe
von Schwimmbädern unsicher und sollten daher vermieden werden. Wenn das Netzkabel
dieses Produkts beschädigt ist, muss es vom Fach- oder Vertriebshändler durch ein
Originalkabel von Davey ersetzt werden.
ACHTUNG: Davey Water Products empehlt, dass alle Anlagen mit einem
Erdschluss oder Fehlerstrom-Schutzeinrichtungen ausgestattet sind. Die
Netzspeisung dieser Pumpe muss über einen Trenntransformator oder eine
Fehlerstromschutzeinrichtung mit einem Nennbetriebsstrom von maximal 30
mA erfolgen. Aus Sicherheitsgründen empfehlen wir, die Installation unter
Einhaltung der AS3000 Anschlussvorschriften oder der entsprechenden
lokalen Vorschriften durchzuführen. Stellen Sie sicher, dass ein elektrischer
Trennschalter leicht zugänglich ist, sodass die Pumpe im Notfall
ausgeschaltete werden kann.
ACHTUNG: Gemäß AS/NZS 60335.2.41 sind wir verpichtet, Sie zu informieren,
dass diese Pumpe nicht von Kindern oder gebrechlichen Personen bedient und
von Kindern nicht als Spielzeug benutzt werden darf. Wenn Pumpe und Filter
unterhalb des Wasserspiegels im Pool installiert sind, ist es erforderlich, an
der Leitung zwischen Pumpe und Skimmerkasten und an der Rücklaueitung
zwischen Pumpe und Filter Absperrventile zu installieren.
WICHTIG: Die Verschraubungen an diesem Produkt bestehen aus ABS. Manche
PVC-Dichtungsmassen sind nicht mit ABS kompatibel. Prüfen Sie die Eignung der
Dichtmasse vor der Verwendung.
GERMAN
17
WARNUNG! Stellen Sie sicher, dass ein leicht zugänglicher elektrischer
Trennschalter installiert ist, um die Pumpe im Notfall von der
Stromversorgung trennen zu können.
Typischer Installationsplan
Wasserpumpe
Sandfilter
Saugschlauch Vakuumkopf
Abmessungen
Leitungsanschluss
Die StarFlo Poolpumpen werden für den Anschluss an die Rohrleitungen vom Pool mit
Rohrverbindern geliefert. Die folgenden Pumpenmodelle sind so ausgelegt, dass sie mit
europäischen 50 & 63 mm PVC-Rohren verbunden werden können.
* DSF150(CE) * DSF420(CE)
* DSF200(CE) * DSF3003F(CE)
* DSF250(CE) * DSF4203F(CE)
* DSF300(CE)
Die folgenden Pumpenmodelle sind so ausgelegt, dass sie mit PVC-Rohren mit einer
Nennweite von 40mm & 50 mm verbunden werden können.
* DSF150 * DSF420
* DSF200 * DSF3003F
* DSF250 * DSF4203F
* DSF300
Vom Einsatz von Rohrleitungen mit kleineren Abmessungen als oben angegeben wird
abgeraten. Saugleitung müssen absolut luftdicht und frei von jeglichen Hohlräumen
und Vertiefungen sein, die die Ansaugleistung beeinträchtigen könnten. Die von der
Pumpe ausgehende Druckleitung ist an den Zulaufanschluss am Schwimmbadlter
(normalerweise am Filter-Regelventil) anzuschließen.
Die Schnellkupplungen werden manuell festgezogen. Der Einsatz von
Dichtmasse, Klebemittel oder Silikon ist nicht erforderlich.
GERMAN
GERMAN
18
Inbetriebsetzung der Pumpe
Um einen einwandfreien Betrieb zu garantieren und jegliche Beschädigung der Pumpe
zu vermeiden, muss an beiden Seiten der Pumpe eine ungehinderte Wasserzirkulation
gewährleistet sein. Vor der Inbetriebsetzung der Pumpe ist Folgendes zu prüfen:
Alle Leitungen müssen sachgemäß abgedichtet sein.
Der Schwimmbad-Wasserspiegel muss sich auf der richtigen Höhe benden.
Alle Ventile müssen geöffnet sein, und es muss ein ungehinderter Wasserkreislauf in der
Anlage gewährleistet sein.
1. Wenn die Pumpe oberhalb des Schwimmbad-Wasserspiegels installiert ist, muss sie
zunächst entlüftet werden; dazu den Siebkorbdeckel abnehmen und den Siebkorb
mit Wasser auffüllen. Den Deckel wieder aufsetzen und dabei darauf achten, dass die
O-Ringdichtung richtig geschlossen ist.
2. Die Spannungsversorgung und die Anlage einschalten.
3. Die Pumpe laufen lassen, um eventuelle Lufteinschlüsse auszustoßen.
4. Falls innerhalb von rund zwei Minuten die erfolgreiche Entlüftung, die sich an einem
starken Wasserstrom erkennen lässt, nicht erzielt wurde, die Pumpe ausschalten
und den Vorgang wiederholen. Eine fortdauernde Ansammlung von Luft unter dem
Siebkorbdeckel ist ein Anzeichen für eine undichte Saugleitung, was zu beheben ist,
um jegliche Beschädigung der Pumpe zu vermeiden.
Pumpenbetrieb
Für eine optimale Pumpenleistung muss der Siebkorbkasten grundsätzlich mit Wasser gefüllt
und frei von Luftbläschen sein. Der Wasserspiegel des Schwimmbads muss grundsätzlich
mindestens auf halber Höhe des Skimmerkastens gehalten werden, um sicherzustellen,
dass sich jederzeit Wasser in der Pumpe bendet. Gelegentlich kann es erforderlich sein,
die Pumpe erneut zu entlüften. Dazu sind die obenstehenden Anleitungen zu befolgen.
Die Pumpe darf in keinem Fall trocken betrieben werden. Bei dem Betrieb
der Pumpe ohne Wasser können die mechanischen Dichtungen beschädigt
werden, was wiederum zu Undichtigkeiten oder einer Überutung führen
kann. Schäden infolge trockenen Betriebs und damit verbundene Schäden
fallen nicht unter die Garantieleistung. Davey StarFlo Schwimmbadpumpen
sind mit einem Thermowächter mit automatischer Rückstellung
ausgestattet, um potenzielle Schäden zu minimieren.
GERMAN
19
Entleeren des Siebkorbs
Der Siebkorb muss regelmäßig durch den transparenten Deckel geprüft und im Falle
angesammelter Verschmutzungen entleert werden. Dazu sind die nachstehenden
Anleitungen zu befolgen.
1. Die Pumpe ausschalten und von der Spannungsversorgung trennen.
2. Alle Leitungsventile schließen.
3. Den Siebkorbdeckel gegen den Uhrzeigersinn abschrauben und abnehmen.
4. Den Siebkorb nach oben aus seinem Kasten heben.
5. Die im Korb bendlichen Verschmutzungen entfernen. Bei Bedarf mit Wasser ausspülen.
6. Den Siebkorb auf Risse prüfen und wieder in die Pumpe einsetzen, sofern sein Zustand
einwandfrei ist. Wenn der Siebkorb nicht regelmäßig gewartet wird, können Schäden
entstehen, die nicht unter die Garantieleistung fallen.
7. Den Deckel wieder aufsetzen und dabei darauf achten, dass die O-Ring-Gummidichtung
richtig geschlossen ist. Es ist ausreichend, den Deckel mit der Hand festzuziehen.
Der O-Ring und das Gewinde können mit Schmiermittel der Marke Hydra Slip oder
gleichwertigen Produkten geschmiert werden.
8. Alle Leitungsventile öffnen.
Wenn der Siebkorb nicht regelmäßig gewartet wird, können Schäden
entstehen, die nicht unter die Garantieleistung fallen.
GERMAN
GERMAN
20
Fehlerbehebung
Wenn beim Betrieb der Pumpe der Wasserstrom unterbrochen oder eingeschränkt ist,
kann dies folgende Ursachen haben:
1. Der Filter benötigt eine Rückspülung oder ist verstopft. Siehe entsprechenden Abschnitt
im Filterhandbuch.
2. Die Pumpe wurde nicht entlüftet. Die Pumpe gemäß den Anleitungen unter
„Inbetriebsetzung der Pumpe“ erneut entlüften.
3. Die Saugleitung weist Undichtigkeiten auf. Alle Leitungen prüfen und eventuelle
Undichtigkeiten beheben, auch den Siebkorbdeckel auf festen Sitz prüfen. Luftbläschen
in dem zum Schwimmbad zurückgeleiteten Wasser sind Anzeichen für eine Undichtigkeit
in der Saugleitung der Pumpe, durch die Luft in die Leitungen gerät.
4. Eine undichte Pumpenwellendichtung kann den Betrieb ebenfalls beeinträchtigen. Ein
Anzeichen dafür ist eine Wasserlache auf dem Boden unter der Pumpe.
5. Die Pumpe saugt das Schwimmbadwasser nicht an. Prüfen, dass die Ventile der
Saugleitung der Pumpe vollständig geöffnet sind, und dass sich der Schwimmbad-
Wasserspiegel auf halber Höhe des Skimmerkastens bendet.
6. Verstopfung in den Leitungen oder in der Pumpe. Den Siebkorb herausnehmen und das
Pumpenlaufrad auf Hindernisse am Einlass prüfen. Den Skimmerkasten auf hinderliche
Fremdkörper prüfen.
Wenn sich die Pumpe nicht in Betrieb setzen lässt, kann dies folgende Ursachen haben:
1. Die Spannungsversorgung ist nicht angeschlossen. Ausschließlich bei 220-240 Volt-
Anschlüssen kann mit einem mobilen Gerät geprüft werden, dass Strom verfügbar ist.
Auch die Sicherungen und der Hauptstromschalter sind zu prüfen.
2. Der automatische Überlastschutz wird nach einem bestimmten Überhitzung-Zeitintervall
ausgelöst. Die Pumpe ist mit einem integrierten Thermowächter ausgestattet, der sich
automatisch zurücksetzt, sobald der Motor abgekühlt ist. Die Ursache für die Überlast-
Auslösung ermitteln und beheben.
3. Eine Blockierung verhindert die Rotation der Pumpe.
4. Durchgebrannter Motor – am Verbrennungsgeruch erkennbar. Der Motor muss
ausgewechselt werden.
Wenn Sie nicht in der Lage sind, Installations- oder Betriebsprobleme Ihrer Davey StarFlo
Schwimmbadpumpe selbst zu beheben, wenden Sie sich an den Händler, bei dem Sie die
Pumpe erworben haben. Wenn Sie weitere Hilfe benötigen, wenden Sie sich an das Davey
Kundendienstzentrum unter den in diesem Handbuch angegebenen Kontaktdaten.
Reparatur- und Wartungsarbeiten an der Anlage müssen vom Hersteller oder qualiziertem
Personal des Fachhändlers ausgeführt werden.
GERMAN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Davey DSF3003FCE Istruzioni per l'uso

Tipo
Istruzioni per l'uso
Questo manuale è adatto anche per