ProLights 12x8W RGBWAP / FC high-power PAR LED Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente
USER MANUAL
MANUALE UTENTE
LUMIPAR12UH3P
EN - IT
SUPER-SLIM PARLED
LUMIPAR12UH3P
All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals section on site www.musiclights.it
REV.003-05/17
Packing content
LUMIPAR12UH3P
Mount bracket (2pc.)
Power cable
User manual
TABLE OF CONTENTS
Safety
General instructions
Warnings and installation precautions
1 Introduction
1. 1 Description
1. 2 Technical specications
1. 3 Operating elements and connections
2 Installation
2. 1 Mounting
3 Functions and settings
3. 1 Operation
3. 2 Basic
3. 3 Menu structure
3. 4 Auto show
3. 5 Static Color
3. 6 Sound Mode
3. 7 Manual Color
3. 8 Dimmer
3. 9 Linking
3. 10 DMX conguration
3. 11 DMX addressing
3. 12 Connection of the DMX line
3. 13 Construction of the DMX termination
3. 14 DMX control
3. 15 Operation through the IRC controller
4 Maintenance
4. 1 Maintenance and cleaning the unit
4. 2 Fuse replacement
4. 3 Troubleshooting
2
2
4
4
6
7
8
8
9
9
9
10
10
10
10
10
11
12
12
13
14
15
15
15
LUMIPAR12UH3P
2
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.
SAFETY
General instruction
The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
This unit is not for home use, only professional applications.
Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 45 °C.
Make certain that no inammable liquids, water or metal objects enter the xture.
Do not dismantle or modify the xture.
All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
Always additionally secure the projector with the safety rope. When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
Install the xture in a well ventilated place.
Keep any inammable material at a safe distance from the xture.
Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally deformed.
Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
Do not touch the product’s housing when operating because it may be very hot.
3
LUMIPAR12UH3P
- 1 - INTRODUCTION
1.1 DESCRIPTION
LUMIPAR12UH3P is a super-slim PAR LED designed for professional use and as a powerful wash lightwith
the ability to perform an outstanding chromatic capacity through the new optical design and light source
based on 6 colours mixing. LUMIPAR12UH is compatible with the infrared remote controller, for intuitive
and interactive use without need any external DMX units and can be also controlled wireless through the
optional USB WIFI transceiver in combination with WIFIBOX and the SmartColor app.
1.2 TECHNICAL SPECIFICATIONS
LIGHT SOURCE
Source: 12x8W RGBWAP LEDs
Luminous ux: 2537lm
Lux: 963,5lux @3m
Source life expectancy: >50.000 h
OPTICS
Beam angle: 25°
Field angle: 45°
Lens diameter: 38mm
Additional optics: 25° (inc) - 45° (op)
COLOUR SYSTEM
Colour mixing: RGBWAP/FC
White presets: 3200~10000K
Colour wheel: virtual colour wheel with presets
Macros: built-in white presets
DYNAMIC EFFECTS
Static colour mode: selection of static colour
Manual colour mode: manual adjustment of dimmer and strobe
Auto mode: built-in programs with execution speed adjustment
BODY
Body: sturdy die-cast aluminium body conceived for long-time durability
Body colour: black
CONTROL
Protocols: DMX512
DMX channels: 6/11channel
Display: LED display user interface
Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
IR: infrared sensor controlled by remote
Master/Slave: for synchronized operation of more units linked in a chain
ELECTRONICS
Dimmer: linear 0~100% electronic dimmer
Strobe / shutter: 1-28 Hz, electronic
Operating temperature: -10° ~ +45°
Flicker: icker free operation
ELECTRICAL
Power supply: 100-240V – 50/60Hz
Power consumption (at 230V): 83W
Power consumption (at 120V): 84,5W
Output (at 230V): 30 units on a single power line
LUMIPAR12UH3P
4
Technical drawing
Fig.1
200
253 237
Output (at 120V): 16 units on a single power line
PHYSICAL
Cooling: natural cooling of the peculiar chassis and to absence of fans
Sospension and xing: double hanging bracket suitable for safe hanging and for oor positioning
Data: USB port for USB WIFI transmitter (optional)
Signal connection: XLR 3p IN/OUT connectors
Power connection: variants available
IP rating: 44
Dimensions (WxHxD): 253x200x237mm
Weight: 3.3kg
5
LUMIPAR12UH3P
1.3 OPERATING ELEMENTS AND CONNECTIONS
Fig.2 - Rear panel
1. MOUNTING BRACKET.
2. LOCKING KNOB for the mounting bracket.
3. DMX IN (3-pole XLR):
1 = ground, 2 = DMX -, 3 = DMX +.
4. DMX OUT (3-pole XLR):
1= ground, 2 = DMX -, 3 = DMX +.
5. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them.
6. POWER IN (PowerCON IN) mains plug for
connection to a socket (100-240V~/50/60Hz)
via the supplied mains cable.
7. MICROPHONE to control the show by the
external audio signal.
8. SAFETY EYE to attach safety cable.
9. Universal Serial Bus (USB).
10. POWER OUT (PowerCON OUT): power output
for connection of multiple units in series.
11. GND POINT grounding the xture to the earth.
1
2
63 4 5 7
11108 9
LUMIPAR12UH3P
6
- 2 - INSTALLATION
2.1 MOUNTING
LUMIPAR12UH3P may be set up on a solid and even surface. The unit can also be mounted upside down
to a cross arm. For xing, stable mounting clips are required. The mounting place must be of sucient
stability and be able to support a weight of 10 times of the units weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xtures being used.
Install the projector at a suitable location by means of the mounting bracket (1).
Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
Adjust the projector and use the knob (2) to slightly release or tighten the locking mechanism of the
bracket if is necessary.
Fig.3
2
1
7
LUMIPAR12UH3P
Fig.4 - Functions of the buttons
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
Connect the supplied main cable to a socket (100-240 VAC-50/60 Hz). Then the unit is ready for operation
and can be operated via a DMX controller or it independently performs its show program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the LED Display
(g.4).
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
MENU UP DOWN ENTER
LUMIPAR12UH3P
8
3.3 MENU STRUCTURE
3.4 AUTO SHOW
This xture has a built-in automatic program. To access this, please see the below instructions:
Press the button MENU so many times until shows P-- , then press the button ENTER.
Using UP/DOWN button, select one of the programs P1 - P4.
Press the button ENTER to conrm.
Press the button MENU until S-- appears on the display.
Use the button UP/DOWN to select the auto programs speed S001 - S100 (slow-fast).
Press the button ENTER save the setting.
3.5 STATIC COLOR
This xture has the ability to accept custom static color settings. Access these chases via the control panel
on the back of the xture.
MENU
1
DMX Personality and
Starting Address
6 CH
ð
d1 - d512
Selects DMX personality and DMX starting
value
11 CH
ð
d1 - d512
2 Static Colors C--
ð
C1 - C63 Selects 1 of 63 static colors
3 Auto Programs P--
ð
P1 - P4 Selects 1 of 4 auto programs
4 Programs Speed S--
ð
S1 - S100 Sets auto program speed (slow to fast)
5 Sound Active Snd
ð
Snd1 - Snd2 Selects Sound Active mode
6 Sound Sensitivity SenS
ð
u0 - u100 Sets sound sensitivity (low to high)
7 Custom Color Mixing U--
ð
r0 - r255 Red (0-100%)
ð
g0 - g255 Green (0-100%)
ð
b0 - b255 Blue (0-100%)
ð
A0 - A255 Amber (0-100%)
ð
W0 - W255 White (0-100%)
ð
P0 - P255 Purple (0-100%)
8 Dimmer dIM
ð
OFF OFF: Dimmer speed o
ð
dIM1 DIM1: Dimmer speed fast
ð
dIM2 DIM2: Dimmer speed middle
ð
dIM3 DIM3: Dimmer speed slow
9 Infrared SET
ð
ON
Turns infrared on or o
ð
OFF
9
LUMIPAR12UH3P
Press the button MENU so many times until shows C-- , then press the button ENTER.
Using UP/DOWN button, select one of the programs C1 - C63.
Press the button ENTER to conrm.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3.6 SOUND MODE
In music mode, via its integrated microphone, the unit can be controlled by music with a clear rhythm in
the bass range. If the music control should not work optimally, increase the volume or reduce the distance
between the sound source and the light eect unit.
Press the button MENU so many times until the display shows Snd.
Using UP/DOWN button, select one of the modes Snd1 or Snd2.
Press the button ENTER to conrm.
You can set the microphone sensitivity pressing the button MENU so many times until the display show Sens.
Using the button UP/DOWN, select the desired value sensitivity (slow-fast) u0 - u100.
Press the button ENTER to conrm.
3.7 MANUAL COLOR
This mode allows to combine the colors red, green, blue, amber, white and purple (r, g, b,A, W, P).
Press the button MENU so many times until the display shows U-- , then press the button ENTER.
Select the color r, g, b, A, W or P through the buttons UP/DOWN.
Press the button ENTER to conrm.
Using UP/DOWN button, select the desired color value 000 - 255.
Press ENTER button to continue to the next color.
Continue until the desired mix is obtained.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3.8 DIMMER
Enter in Dimmer mode to select specic dimming curve, press the button MENU so many times until
shows dIM, and press the button ENTER to conrm.
Press the button UP/DOWN to select OFF - dIM1 - dIM2 - dIM3.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3.9 LINKING
Several units may be interconnected in order to control all further slave units to the same eect of the
master unit. Use standard DMX cables to daisy chain your units together via the DMX connector on the
rear of the units. For longer cable runs we suggest a terminator at the last xture (see page 12).
1. Connect the DMX OUT of the master unit via 3-pole XLR cable to the DMX IN of the rst slave unit.
2. Connect the DMX OUT of the rst slave unit to the DMX IN of the second slave unit, etc. until all units
are connected in a chain.
3.10 DMX CONFIGURATION
LUMIPAR12UH3P is equipped with dierent DMX conguration.
Press the button MENU to select the desired DMX conguration (6CH - 11CH), then press the button
ENTER.
LUMIPAR12UH3P
10
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
6 33 33-38 39 45 51
11 33 33-41 44 55 66
Press the button UP/DOWN to select the desider value (001 - 512), then press the button ENTER to con-
rm.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
The tables on page 13 indicate the operating mode and DMX value. The LUMIPAR12UH3P is equipped
with 3-pole XLR connections.
3.11 DMX ADDRESSING
To able to operate the LUMIPAR12UH3P with a light controller, adjust the DMX start address for the rst a
DMX channel. If e. g. address 33 on the controller is provided for controlling the function of the rst DMX
channel, adjust the start address 33 on the LUMIPAR12UH3P.
The other functions of the light eect panel are then automatically assigned to the following addresses.
An example with the start address 33 is shown below:
DMX Address: 51DMX Address: 39DMX Address: 33 DMX Address: 45
Fig.5 - Example 6 DMX channels conguration
............
DMX512 Controller
11
LUMIPAR12UH3P
Fig.6
Fig.7
3.12 CONNECTION OF THE DMX LINE
DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω imped-
ance and low capacity.
The following diagram shows the connection mode:
ATTENTION
The screened parts of the cable (sleeve) must never be connected to the systems earth, as this would
cause faulty xture and controller operation.
Over long runs can be necessary to insert a DMX level matching amplier.
For those connections the use of balanced microphone cable is not recommended because it cannot
transmit control DMX data reliably.
Connect the controller DMX input to the DMX output of the rst unit.
Connect the DMX output to the DMX input of the following unit. Connect again the output to the input
of the following unit until all the units are connected in chain.
When the signal cable has to run longer distance is recommended to insert a DMX termination on the
last unit.
3.13 CONSTRUCTION OF THE DMX TERMINATION
The termination avoids the risk of DMX 512 signals being reected back along the cable when they reach-
es the end of the line: under certain conditions and with certain cable lengths, this could cause them to
cancel the original signals.
The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the 3-pin male XLR
connector, as shown in gure.
DMX - OUTPUT
XLR socket
DMX - INPUT
XLR plug
Pin1 : GND - Shield
Pin2 : - Negative
Pin3 : + Positive
Example:
3 pin XLR connector
LUMIPAR12UH3P
12
3.14 DMX CONTROL
6 CHANNELS
MODE
FUNCTION DMX
Value
6 Ch
1
RED
0~100% 000 - 255
2
GREEN
0~100% 000 - 255
3
BLUE
0~100% 000 - 255
4
AMBER
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
PURPLE
0~100% 000 - 255
11 CHANNELS
MODE
FUNCTION DMX
Value
11 Ch
1
RED
0~100% 000 - 255
2
GREEN
0~100% 000 - 255
3
BLUE
0~100% 000 - 255
4
AMBER
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
PURPLE
0~100% 000 - 255
7
COLOR MACRO
No Function
Color Macros
000 - 015
016 - 255
8
STROBE
No Function
Strobe slow to fast
000 - 015
016 - 255
PROGRAM SPEED
Speed slow to fast 000 - 255
SOUND SENSITIVITY
Sound sensistivity OFF
Control the sound sensitivity
000 - 010
011 - 255
9
PROGRAMS
No function
0 - 100%
100%-0
100%-0-100%
Colors Fade
6 Colors snap
63 Colors snap
Sound Control
000 - 031
032 - 063
064 - 095
096 - 127
128 - 159
160 - 191
192 - 223
224 - 255
10
DIMMER
0~100% 000 - 255
11
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode 1 (fast speed)
Dimmer speed mode 2 (middle speed)
Dimmer speed mode 3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
13
LUMIPAR12UH3P
3.15 OPERATION THROUGH THE IRC CONTROLLER
To control the LUMIPAR12UH3P with the infrared remote control:
Press the button MENU repeatedly until SET, then press button ENTER to conrm.
Using UP/DOWN button to select On or O to enable or disable the infrared remote control.
Press the button ENTER to conrm the chose.
NOTE - Make sure to point the controller directly at the receiver on the product.
Automatic Mode
Automatic Mode will enable you to run the automatic programs on the
product.
To turn on Automatic Mode:
1. Press AUTO on the controller.
2. Press + or – to choose between the dierent auto programs.
To adjust the speed of the automatic program:
1. Press SPEED on the controller.
2. Press %.
3. Press + or – to either increase or decrease the speed of the program.
Sound Active Mode
Sound Active Mode will enable the product to respond to the music.
To turn on Sound Active mode:
1. Press SOUND on the controller.
To adjust sound sensitivity in Sound Active mode:
1. Press SENSITIVITY on the controller.
2. Press %.
3. Press + or – to either increase or decrease sound sensitivity.
Manual Color Control
To choose a specic color with the controller:
1. Press MANUAL on the controller.
2. Press any number between 0-9 to choose your color.
To manually control the RGBAWP percentage:
3. Press MANUAL on the controller.
4. Press R, G, B, A, W or P to choose your color.
5. Press + or – to increase or decrease the percentage of each color.
Miscellaneous Operation
To adjust the strobe rate of the program:
1. Press STROBE on the controller.
2. Press + or – to increase or decrease the strobe rate.
3. Press STROBE again to turn o the strobe.
To change the switching eect of the program:
Press FADE/SNAP on the controller.
Fade will slowly switch the eect. Snap will rapidly switch the eect.
To black out the lights:
Press BLACK OUT on the controller.
This will turn o all the lights until the button is pressed again.
NOTE - The controller will not respond to any inputs when Black Out is activated. If the remote does not
respond when a button is pressed, try pressing BLACK OUT. You may have inadvertently activated BLACK
OUT.
Fig.8
IRC REMOTE
BLACK
OUT
AUTO
STROBE SPEED
SOUND
SENSI-
TIVITY
%
MANUAL
FADE
R
G B
+
0
1
2
3
4
5
6
7 8 9
A
UV W
LUMIPAR12UH3P
14
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
Make sure the area below the installation place is free from unwanted persons during setup.
Switch o the unit, unplug the main cable and wait until the unit has cooled down.
All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
Housings, xations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
4.2 FUSE REPLACEMENT
1. Disconnect this product from the power outlet.
2. Remove the safety cap by a screwdriver.
3. Replace the blown fuse with a fuse of the exact same type and
rating.
4. Install the safety cap, and reconnect power.
4.3 TROUBLESHOOTING
Fuse
Fig.9
Problems Possible causes Checks and remedies
Fixture does not light up
No mains supply
Dimmer fader set to 0
All color faders set to 0
Faulty LED
Faulty LED board
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Replace the LED board
Replace the LED board
General low light intensity
Dirty lens assembly
Misaligned lens assembly
Clean the xture regularly
Install lens assembly properly
Fixture does not power up
No power
Loose or damaged power cord
Faulty internal power supply
Check for power on power outlet
Check power cord
Replace internal power supply
Fixture does not respond to DMX
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
REV.003-05/17
Music & Lights S.r.l. si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l’uso.
La riproduzione - anche parziale - per propri scopi commerciali è vietata.
Al ne di migliorare la qualità dei prodotti, la Music&Lights S.r.l. si riserva la facoltà di modicare, in
qualunque momento e senza preavviso, le speciche menzionate nel presente manuale di istruzioni.
Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione 'Manuali' sul sito www.musiclights.it
LUMIPAR12UH3P
Staa di ssaggio (2pz.)
Cavo di alimentazione
Manuale utente
Contenuto dell'imballo:
INDICE
Sicurezza
Avvertenze generali
Attenzioni e precauzioni per l’installazione
1 Introduzione
1. 1 Descrizione
1. 2 Speciche tecniche
1. 2 Elementi di comando e di collegamento
2 Installazione
2. 1 Montaggio
3 Funzioni e impostazioni
3. 1 Funzionamento
3. 2 Impostazione base
3. 3 Struttura menu
3. 4 Autoshow
3. 5 Static Color
3. 6 Modalità Musicale
3. 7 Manual Color
3. 8 Funzione dimmer
3. 9 Collegamento
3. 10 Congurazione canali DMX
3. 11 Indirizzamento DMX
3. 12 Collegamenti della linea DMX
3. 13 Costruzione del terminatore DMX
3. 14 Canali DMX
3. 15 Funzionamento tramite il controller IRC
4 Manutenzione
4. 1 Manutenzione e pulizia del sistema ottico
4. 2 Sostituzione fusibile
4. 3 Risoluzione dei problemi
4
4
5
5
7
8
9
9
10
10
11
11
11
11
11
11
12
13
13
14
15
16
16
16
LUMIPAR12UH3P
4
ATTENZIONE! Prima di effettuare qualsiasi operazione con l’unità, leggere con attenzione
questo manuale e conservarlo accuratamente per riferimenti futuri. Contiene informazioni
importanti riguardo l’installazione, l’uso e la manutenzione dell’unità.
SICUREZZA
Avvertenze generali
I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunità Europea e per-
tanto recano la sigla .
Il dispositivo funziona con pericolosa tensione di rete 230V~. Non intervenire mai al suo interno al di
fuori delle operazioni descritte nel presente manuale; esiste il pericolo di una scarica elettrica.
È obbligatorio eettuare il collegamento ad un impianto di alimentazione dotato di uneciente messa
a terra (apparecchio di Classe I secondo norma EN 60598-1). Si raccomanda, inoltre, di proteggere le
linee di alimentazione delle unità dai contatti indiretti e/o cortocircuiti verso massa tramite l’uso di
interruttori dierenziali opportunamente dimensionati.
Le operazioni di collegamento alla rete di distribuzione dell’energia elettrica devono essere eettuate
da un installatore elettrico qualicato. Vericare che frequenza e tensione della rete corrispondono alla
frequenza ed alla tensione per cui l’unità è predisposta, indicate sulla targhetta dei dati elettrici.
L’unità non per uso domestico, solo per uso professionale.
Evitare di utilizzare l’unità:
- in luoghi soggetti a vibrazioni, o a possibili urti;
- in luoghi a temperatura superiore ai 45°C.
Evitare che nell’unità penetrino liquidi inammabili, acqua o oggetti metallici.
Non smontare e non apportare modiche all’unità.
Tutti gli interventi devono essere sempre e solo eettuati da personale tecnico qualicato. Rivolgersi al
più vicino centro di assistenza tecnica autorizzato.
Se si desidera eliminare il dispositivo denitivamente, consegnarlo
per lo smaltimento ad un’istituzione locale per il riciclaggio.
Attenzioni e precauzioni per l’installazione
Se il dispositivo dovesse trovarsi ad operare in condizioni dierenti da quelle descritte nel presente
manuale, potrebbero vericarsi dei danni; in tal caso la garanzia verrebbe a decadere. Inoltre, ogni altra
operazione potrebbe provocare cortocircuiti, incendi, scosse elettriche, rotture etc.
Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull’unità togliere la tensione dalla rete
di alimentazione.
È assolutamente necessario proteggere l’unità per mezzo di una fune di sicurezza. Nell’eseguire qual-
siasi intervento attenersi scrupolosamente a tutte le normative (in materia di sicurezza) vigenti nel
paese di utilizzo.
Installare l’unità in un luogo ben ventilato.
Mantenere i materiali inammabili ad una distanza di sicurezza dall’unità.
I ltri, le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro ecienza.
I LED devono essere sostituiti se danneggiati o termicamente deformati.
Non guardare direttamente il fascio luminoso. Tenete presente che i veloci cambi di luce possono pro-
vocare attacchi d’epilessia presso persone fotosensibili o epilettiche.
Non toccare l’alloggiamento del prodotto quando è in funzione perché potrebbe essere molto caldo.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

ProLights 12x8W RGBWAP / FC high-power PAR LED Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente