APC Rack PDU,Basic,ZeroU,5.7kW,120V Manuale utente

Categoria
Unità di distribuzione dell'alimentazione (PDU)
Tipo
Manuale utente
Installation
Basic Rack Power
Distribution Unit
This manual is available in English on the enclosed CD.
Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM
verfügbar.
Este manual está disponible en español en el CD-ROM adjunto.
Ce manuel est disponible en français sur le CD-ROM ci-inclus.
Questo manuale è disponibile in italiano nel CD-ROM allegato.
本マニュアルの日本語版は同梱 CD-ROM からご覧になれ
ます。
Instrukcja Obs
ługi w jezyku polskim jest dostepna na CD.
Данное руководство на русском языке имеется на
прилагаемом компакт-диске.
O manual em Português está disponível no CD-ROM em anexo.
Bu kullanim kilavuzunun Türkçe'sä, äläxäkte gönderälen CD
äçeräsände mevcuttur.
您可以从包含的 CD 上获得本手册的中文版本。
Contents
Basic Rack Power Distribution Unit i
Preliminary Information . . . . . . . . . . . . . . . . . .1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Receiving inspection . . . . . . . . . . . . . . . . . . . 1
Please recycle . . . . . . . . . . . . . . . . . . . . . . . . 1
How to Install the Rack PDU . . . . . . . . . . . . . .2
Attach the cord retention trays . . . . . . . . . . . 2
Attach cords to the tray . . . . . . . . . . . . . . . . . 2
Mounting options . . . . . . . . . . . . . . . . . . . . . . 3
Toolless mounting . . . . . . . . . . . . . . . . . . . . . 3
Bracket-mounting . . . . . . . . . . . . . . . . . . . . . 4
Warranty and Service . . . . . . . . . . . . . . . . . . . .6
Limited warranty . . . . . . . . . . . . . . . . . . . . . . 6
Warranty limitations . . . . . . . . . . . . . . . . . . . . 6
Obtaining service . . . . . . . . . . . . . . . . . . . . . . 6
Life-Support Policy . . . . . . . . . . . . . . . . . . . . . .8
General policy . . . . . . . . . . . . . . . . . . . . . . . . 8
Examples of life-support devices . . . . . . . . . 8
Basic Rack Power Distribution Unit 1
Preliminary Information
Features
This booklet provides information on installing
and operating American Power Conversion
(APC
®
)
Rack Power Distribution Units (PDUs).
Receiving inspection
Inspect the package and contents for shipping
damage, and make sure that all parts were sent.
Report any damage immediately to the shipping
agent, and report missing contents, damage, or
other problems immediately to APC or your APC
reseller.
Please recycle
The shipping materials are recyclable.
Please save them for later use, or dispose
of them appropriately.
2 Basic Rack Power Distribution Unit
Install the Rack PDU
Attach the cord retention trays
Attach the cord retention trays to the Rack PDU,
using four flat-head screws (provided) per tray.
Attach cords to the tray
Attach a cord to the tray by looping the cord and
securing it to the tray, using a wire tie (provided).
pdu0123b
No t e
Each cord must be secured to the tray
so that you can unplug it from the PDU
without removing the wire tie.
No t e
When installing the PDUs, ensure that
the power cord plug is accessible, and
that the PDU is connected to a
grounded outlet.
pdu0127b
Install the Rack PDU
Basic Rack Power Distribution Unit 3
Mounting options
You can install the Rack PDU in one of two ways:
using toolless mounting pegs (provided) or
mounting brackets (provided). The 1-U and 2-U
horizontal Rack PDUs must be mounted using the
horizontal mounting brackets.
Vertical mounting.
• To install the Rack PDU using the toolless
mounting method, install it in the rear of the
NetShelter
®
VX or SX Enclosure, in the cable
channel directly behind the rear vertical
mounting rails.
• To install the Rack PDU using the mounting
brackets, install it on a vertical mounting rail
on your rack or enclosure.
Horizontal mounting.
To install the Rack PDU using the horizontal
mounting brackets, install the brackets on the Rack
PDU and then attach the PDU to the rack using
caged nuts (provided with your enclosure).
Toolless mounting
1. Slide both mounting pegs into the holes
located in the channel in the rear panel of the
enclosure.
2. Snap the Rack PDU into place by pushing it
downward until it locks into position.
No t e
You can mount two PDUs on one side
of the enclosure by using the toolless
mounting method.
pdu0119b
Install the Rack PDU
4 Basic Rack Power Distribution Unit
Bracket mounting
Vertical mounting. To mount the Rack PDU
vertically in a NetShelter or any standard EIA-310
rack or enclosure:
1. Attach the vertical-mounting brackets to the
PDU.
2. Install the Rack PDU on a vertical mounting
rail in your rack or enclosure using the
supplied screws and caged nuts with your
enclosure.
Caution
Use only the supplied screws.
pdu0344a
pdu0190b
Install the Rack PDU
Basic Rack Power Distribution Unit 5
Horizontal mounting. You can mount the Rack
PDU in a 19-inch NetShelter or other EIA-310-D
standard 19-inch rack:
1. Choose a mounting position for the Rack PDU
with either the display or the rear facing out of
the enclosure.
2. Attach the mounting brackets to the Rack
PDU, using the flat-head screws (provided).
3. Choose a location for the unit:
a. Insert caged nuts (provided with the
enclosure) above and below a notched hole
on each vertical mounting rail in your
chosen location.
b. Align the mounting holes of the brackets
with the installed caged nuts. Insert and
tighten screws.
No t e
The unit occupies one U-space. A
notched hole (or number, on newer
enclosures) on the enclosure’s
vertical rail indicates the middle of a
U-space.
pdu0352a
pdu0353a
6 Basic Rack Power Distribution Unit
Warranty and Service
Limited warranty
APC warrants the Rack PDU to be free from
defects in materials and workmanship for a period
of two years from the date of purchase. Its
obligation under this warranty is limited to
repairing or replacing, at its own sole option, any
such defective products. This warranty does not
apply to equipment that has been damaged by
accident, negligence, or misapplication or has been
altered or modified in any way. This warranty
applies only to the original purchaser.
Warranty limitations
Except as provided herein, APC makes no
warranties, express or implied, including
warranties of merchantability and fitness for a
particular purpose. Some jurisdictions do not
permit limitation or exclusion of implied
warranties; therefore, the aforesaid limitation(s) or
exclusion(s) may not apply to the purchaser.
Except as provided above, in no event will APC
be liable for direct, indirect, special, incidental,
or consequential damages arising out of the use
of this product, even if advised of the possibility
of such damage.
Specifically, APC is not liable for any costs, such
as lost profits or revenue, loss of equipment, loss
of use of equipment, loss of software, loss of data,
costs of substitutes, claims by third parties, or
otherwise. This warranty gives you specific legal
rights and you may also have other rights, which
vary according to jurisdiction.
Obtaining service
To obtain support for problems with your Rack
PDU:
0
1. Note the serial number and date of purchase.
The serial number is located on the bottom of
the PDU.
2. Contact Customer Support at a phone number
on the back cover of this document. A
technician will try to help you solve the
problem by phone.
3. If you must return the product, the technician
will give you a return material authorization
(RMA) number. If the warranty expired, you
will be charged for repair or replacement.
Warranty and Service
Basic Rack Power Distribution Unit 7
4. Pack the unit carefully. The warranty does not
cover damage sustained in transit. Enclose a
letter with your name, address, RMA number
and daytime phone number; a copy of the sales
receipt; and a check as payment, if applicable.
5. Mark the RMA number clearly on the outside
of the shipping carton.
6. Ship by insured, prepaid carrier to the address
provided by the Customer Support technician.
8 Basic Rack Power Distribution Unit
Life-Support Policy
General policy
American Power Conversion (
APC) does not
recommend the use of any of its products in the
following situations:
• In life-support applications where failure or
malfunction of the
APC product can be
reasonably expected to cause failure of the
life-support device or to affect significantly its
safety or effectiveness.
• In direct patient care.
APC will not knowingly sell its products for use in
such applications unless it receives in writing
assurances satisfactory to
APC that (a) the risks of
injury or damage have been minimized, (b) the
customer assumes all such risks, and (c) the
liability of American Power Conversion is
adequately protected under the circumstances.
Examples of life-support devices
The term life-support device includes but is not
limited to neonatal oxygen analyzers, nerve
stimulators (whether used for anesthesia, pain
relief, or other purposes), autotransfusion devices,
blood pumps, defibrillators, arrhythmia detectors
and alarms, pacemakers, hemodialysis systems,
peritoneal dialysis systems, neonatal ventilator
incubators, ventilators (for adults and infants),
anesthesia ventilators, infusion pumps, and any
other devices designated as “critical” by the
U.S.
FDA
.
Hospital-grade wiring devices and leakage current
protection may be ordered as options on many
APC UPS systems. APC does not claim that units
with these modifications are certified or listed as
hospital-grade by
APC or any other organization.
Therefore these units do not meet the requirements
for use in direct patient care.
*990-1902A-001*
APC Worldwide Customer
Support
Customer support for this or any other APC product is available at
no charge in any of the following ways:
Visit the APC Web site to access documents in the APC
Knowledge Base and to submit customer support requests.
www.apc.com (Corporate Headquarters)
Connect to localized APC Web sites for specific
countries, each of which provides customer support
information.
www.apc.com/support/
Global support searching APC Knowledge Base and
using e-support.
Contact an APC Customer Support center by telephone or
e-mail.
Regional centers:
Local, country-specific centers: go to www.apc.com/
support/contact for contact information.
Contact the
APC representative or other distributor from whom
you purchased your
APC product for information on how to
obtain local customer support.
Direct InfraStruXure
Customer Support Line
(1)(877)537-0607
(toll free)
APC headquarters U.S.,
Canada
(1)(800)800-4272
(toll free)
Latin America (1)(401)789-5735
(USA)
Europe, Middle East,
Africa
(353) (91)702000
(Ireland)
Japan (0) 35434-2021
Australia, New Zealand,
South Pacific area
(61) (2) 9955 9366
(Australia)
Entire contents copyright 2006 American Power Conversion
Corporation. All rights reserved. Reproduction in whole or in
part without permission is prohibited. APC, the APC logo,
NetShelter, and InfraStruXure are trademarks of American
Power Conversion Corporation. All other trademarks, product
names, and corporate names are the property of their respective
owners and are used for informational purposes only.
990-1902A-001
03/2006
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

APC Rack PDU,Basic,ZeroU,5.7kW,120V Manuale utente

Categoria
Unità di distribuzione dell'alimentazione (PDU)
Tipo
Manuale utente