Herschel XLS300W Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

Select XLS
Select XLS range
Smart infrared panel heaters
Select XLS mirror
XLS350M
XLS500M
XLS700M
Select XLS white
XLS300W XLS275W-EU
XLS400W XLS350W-EU
XLS600W XLS500W-EU
XLS800W XLS750W-EU
XLS1100W XLS1000W-EU
Select XLS towel heater
XLS500T
XLS700T
The product complies with European Safety Standards Low Voltage Directive 2014/35/EC, EMC Directive 2014/30/EC, RoHS 2011/65/EC
& Ecodesign requirements for local space heaters 2009/125/EC.
Original instructions covering Select XLS models produced from 06/2019 onwards
Select XLS Glass
XLS800G
EN INSTALLATION & OPERATING INSTRUCTIONS
FR INSTRUCTIONS D'INSTALLATION ET D'UTILISATION
DE INSTALLATIONS- & BEDIENUNGSANLEITUNG
NL INSTALLATIE- EN BEDIENINGSINSTRUCTIES
IT ISTRUZIONI PER L'INSTALLAZIONE E L'USO
ES INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO
MODELS COVERED BY THIS MANUAL:
Serial Number:
Select XLS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY
This appliance must be disconnected from its power source during installation or service activities and when
replacing.
The Select XLS is equipped with SMART-R (located on the rear of the panel), which must be paired to a Herschel XLS
controller (sold separately) to control the room temperature. If you do not use a Herschel XLS controller or similar
room temperature controller, DO NOT use for room heating when rooms are occupied by people incapable of
leaving the room on their own, unless constant supervision is provided. Herschel is not responsible for any breach
of EcoDesign (Lot 20)or Safety legislation where the heaters are used in an enclosed space without use of a
Herschel XLS or similar controller.
The Select XLS has internal safety thermal cut out sensors. However, in order to avoid overheating and potential
fire hazard, DO NOT cover the heater under any circumstances. DO NOT locate the heater within 0.3m of any
flammable materials (eg. Furniture, curtains).
DO NOT touch the heater when in use. Herschel panel heaters have a surface temperature of around 95°C /
248°F (depending upon input voltage) and prolonged contact with the heater will cause burns and injury.
DO NOT operate the heater if the cord or plug is damaged or after the heater malfunctions, or if it has been
dropped or damaged in any manner. Check each heater for damage before installation. Make sure that the heater
itself, the plug (if applicable) and the cable are free of any visible signs of damage. If the cord is damaged the
appliance must be sent for repair to an authorised Herschel Dealer.
This heater must only be used for the heating of people or buildings. The heater is not to be used by children or
persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge. Children should
be kept away and should not be left unsupervised around the unit. DO NOT use outdoors.
All operators should only switch on/off the appliance provided that it has been placed or installed in its intended
operating position in accordance with these instructions. Children must not plug in, switch on or regulate the
appliance or perform user maintenance including cleaning.
Herschel panels are designed for use with an AC voltage between 220-240 volts, 50 Hz AC.If your supply voltage
exceeds 240 Volts do not use the heater and refer to your local dealer. Failure to adhere to this will void the
warranty.
The heater must be mounted on a non-flammable surface.
WATER INGRESS PROTECTION IP44
Herschel Select XLS heater panels are rated to a standard (minimum IP44) enabling them to be located within zone
2in a bathroom. This means they can be placed above a sink or outside any splash zones, or they can be installed
on the ceiling. They cannot be installed in zones 0 or 1.
However, installation in potentially wet or humid rooms such as bathrooms must be carried out by a suitably
qualified installer and comply with local electrical safety requirements. Installation must be such that
the heater must not be able to become detached from the fittings and fall into a bathtub, shower, swimming pool
or other water container and that switches and other controls cannot be touched by a person in the bath or
shower.
If in doubt, do not install. Herschel Infrared Ltd shall not be liable for any loss, damage or injury caused or resulting
from inadequate fitting or incorrect placement of heaters close to water sources.
IMPORTANT SAFETY PRECAUTIONS
Failure to observe these instructions will invalidate the warranty.
Do not disassemble. No user-serviceable parts inside.
ENGLISH
Select XLS
Thankyou for purchasing a Herschel Select XLS infrared heater. Incorporating the very latest in control with
Herschel’s SMART-R system, EASYFIX mounting and slimline frameless design, you will enjoy many years of low
energy, smart and comfortable heating.
We’ve tried to make installing and using your heater as easy as possible. Please read these instructions fully and
retain for future reference. If you have any questions our website also has many FAQs or you can call, message or
online chat with us, we are always happy to help ensure that you get the most from your new Herschel heating
system.
This is an infrared panel heater. It heats by
transferring energy directly from the heater into the
room and its contents. Place the heater where it will
not be immediately obstructed by objects like
furniture or where it cannot effectively radiate out,
such as at the edge or in the corners of a room.
Large objects placed in front of the heater will heat
up and can prevent effective heat dispersion into the
room. If you can, avoid placing the heater opposite
windows, open doorways or behind furniture.
Depending upon the size of the heater, You are likely
to be able to feel the gentle warmth from the heater
up to around 3m away but it will continue to radiate
heat out beyond this. When choosing a mounting
position consider whether you wish to directly feel
the heat (e.g. above a sofa) or not. The closer you are
to the heater, the greater the intensity of the heat
you will feel. This is usually down to personal
preference.
The infrared heat will disperse in the same way as
light from an LED panel light. If you are installing
multiple panels in one room try to imagine each
panel being a light and consider how light would
“illuminate” the room your heaters will heat the
room in a similar way.
Positioning
Select XLS White Panels can be mounted on ceilings, walls or portable.
Select XLS Towel rails and mirrors are wall mount only.
ENGLISH
Select XLS
The Select XLS White panels come with a factory fitted plug. They can be easily wall mounted close to an electrical
socket or can be freestanding. Both methods require the use of either the XLS controls (either the plug in control T-
PL or battery control T-BT). See controls section.
Plug and Play Options simple wall mounting & portable (white panels only)
Wall mounting (DIY installation)
Mount on the wall using the EASYFIX mounting bracket and
simply plug in the heater (only applies to white panels supplied
with a fitted plug).
This is relatively straightforward for a competent DIY person.
The panel will need to be mounted close to an electrical socket
but MUST NOT be mounted immediately below a socket and
no closer than 200mm away from the socket. The SMART-R
box on the rear of the panel should be located at the bottom
of the panel. The panel can be mounted in either landscape or
portrait position (see detailed installation instructions). Be
careful when drilling holes for the EASYFIX mounting bracket to
be clear of electric cables within the walls. If in doubt do not
install and refer to a qualified electrician.
min 200mm
Freestanding / portable use
The Select XLS White panels can be used freestanding or as
portable heaters e.g. for temporary or seasonal heating. For
portable use we strongly recommend the use of Herschel Feet.
These are specially designed to reduce the risk of the heater
falling over and to prevent the bottom of the heater having
direct contact with floor surfaces. Feet are an accessory and
are not supplied with the heater. Contact your dealer or the
Herschel Website for details.
Select XLS Mirrors and Towel Heaters are not suitable for
portable use. They are supplied without plugs and must be wall
mounted and installed by an appropriately qualified
electrician.
min 200mm
ENGLISH
Select XLS
Mounting the panel on the ceiling will generally give
the best heat dispersion in the room and keeps wall
spaces free. Ceiling mounting is only possible with
white (non-glass) panels. Ceiling mounting will
require removal of the plug and professional
installation and should be carried out by a qualified
electrician. Larger panels 800w and upwards may
require two people to install safely.
The Herschel Select XLS White series can be
mounted on the surface of ceilings using the
supplied EASYFIX mount. If recessing heaters into a
plaster ceiling, maintain 200mm clearance around
all sides of the heater and maintain at least 800mm
between adjacent heaters. Objects in front of the
panel must be at least 400mm away and 200 mm
away from the sides. The distance from the sides of
the heater must always be observed. Failure to do
so will cause excess heat to build up behind the
heater and will void the warranty.
Select XLS White panels are also equipped with wire
mounting points on the rear of the heater. These
mounting points can be used instead of the EASYFIX
bracket where suspended ceiling mounting is
required (e.g. in rooms with high / vaulted ceilings).
Each mounting wire must be capable of supporting
the weight of the panel individually. Suitable
mounting wire kits are an accessory and are not
supplied with the heater. Contact your Herschel
dealer for details.
Ceiling mounting white panels only. Professional installation required
min 200mm
wall / recess
ceiling
ENGLISH
Select XLS
WARNING
Wiring to this appliance must be connected in accordance with the relevant national electrical safety standards. It
is a Class 1 appliance and must be earthed.
When placed in public areas, installation must comply with relevant local electrical standards. For certain public
buildings like schools and care homes the heaters must be installed according to the specific legislation for these
types of buildings.
The electrical supply to each heater should be provided by connecting to a circuit protected by a fuse or residual
current device (RCD) or Ground Fault circuit interrupter (GFCI ) suitable for the electrical rating of the appliance.
Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to
NEUTRAL (‘N’) and the GREEN/YELLOW wire to EARTH (‘E’).
CAUTION
Ensure mains power is OFF before commencing an installation involving fixed wiring. Any fixed wiring outside the
heater coming into contact or close proximity to the heater must be protected by sleeving with a temperature
rating of at least 90°c.
All cabling behind the appliance must take the shortest route to the edge of the heater.
Ensure that the power cable is not coiled. Shorten the power cable if possible and do not place excess cable on the
rear of the heater.
Electrical connections must not be made behind the heater regardless of wall or ceiling-mounting position.
The heater is not to be located immediately below a socket outlet in either wall or ceiling-mounted positions.
DO NOT drill through the heater as this will cause irreparable damage and is also dangerous.
DO NOT connect a heater that is damaged in any manner to the power network.
For mounting the Herschel panel use the supplied mounting hardware only and install in accordance with the
installation guide.
The panel may be mounted using the EASYFIX mounting bracket and hard wiredto the electrical supply. For the
white panel range this will require removal of the plug and connection to a suitable connection box positioned
adjacent to the heater. This method of installation must only be carried out by a competent electrician. The SMART-R
box on the rear of the panel should be located at the bottom of the panel. The panel can be mounted in either
landscape or portrait position (see detailed installation instructions).
Fixed wiring into mains. Professional installation required
ENGLISH
Select XLS
Pairing SMART-R to an XLS controller
The heater is equipped with our built-in SMART-R XLS receiver (located on the rear of the panel).
There is a power ON/OFF switch on the receiver and there are indicators to show if the panel is paired to a
controller and if the heating is ON or OFF.
The heater needs to be paired to a Herschel XLS controller (supplied separately). Once paired it will receive ON/OFF
commands from the controller.
IMPORTANT: The panel itself does not have an in-built temperature sensor. Efficient use of the heater is only
possible by pairing it with an XLS controller. The SMART-R XLS receiver will not pair with a non-Herschel XLS
controller. SMART-R WILL NOT pair with a Herschel iQ series control (T1or Hub).
The Herschel XLS controllers can be paired with and control one or many heater panels. The temperature of the
room will be measured by the XLS controller. It is normal to use one controller per room but if it is a large room
(such as open plan area) you may want to consider more than one thermostat controller. If there are multiple
heating panels per room, pair each panel to the relevant room controller.
Operation using with XLS controls
All Herschel Select XLS panels are equipped with a SMART-R XLS receiver on the rear of the rear panel. SMART-R
will pair wirelessly (via RF) with XLS thermostatic controllers. The T-BT is a battery operated thermostat. Wi-Fi and
APP control is not possible with T-BT.
For WiFI and APP control the T-PL is a simple to use thermostat control which plugs into a mains socket. These are
perfect for retrofits and portable heating solutions.
For new build and renovations chose the hard wired T-MT mains powered thermostat which is WiFi enabled.
All control options can be paired with the SMART-R. The controller then sends commands to turn the heater on or
off according to the room temperature and program.
Be sure to follow the pairing instructions closely. Online help is also available via the Help & Support section of
your local Herschel Website.
SMART-R
T-BT
T-MT
T-PL
(no WiFi)
ENGLISH
Select XLS
SMART-R functions on the back of the panel are
1Pairing status LED (green)
2 Heating status LED (red)
3 “Pairing” button
4 Power switch
We recommend that you plug in the unit and pair the
SMART-R to your XLS controller before mounting the panel.
Step 1
Plug your heater into an electrical socket. Switch the power switch (4) “On” .
Press the “Pairing” button (3) on SMART-R twice. The pairing status LED (1) will start to flash.
Step 2
Refer to the pairing guides on your chosen XLS controller for pairing steps on these devices.
Pairing status LED (1) will stop flashing on the panel receiver unit when pairing is complete and will show a steady
green light.
NOTE: The Power Switch (4) will need to be in the ON position to receive commands from the controller and should
be left in the ON position, even when not in use. The panel will not operate if the power switch is OFF. In the event
of a panel failing to heat when required, first check that the Power Switch (4) is in the ON position. The heater is
intended to be turned on or off by the Herschel XLS controller with the Power Switch (4) being an override only.
Controller Bypass
The Select XLS panel can be configured to by-pass the receiver in cases where an alternative control system is
intended to be used (e.g. building management system). In this configuration the panel is connected directly to
the mains electricity supply and controlled (switched on or off) by the alternative control system. Any alternative
control system will need to meet the requirements of LOT 20 in order to ensure compliance (please refer to your
dealer). Use this bypass function if wiring the panel to an alternative (non XLS) controller.
DO NOT operate the Select XLS panel in the bypass state without the use of any external controller. This will
waste energy and is contrary to EcoDesign (Lot 20)and Safety legislation.
To bypass the receiver, with the Power Switch (4) turned “ON”, long press the “Pairing” button (3) until the pairing
status LED (1) turns off and the Heating status LED (2) remains on (red). Follow manufacturer instructions to
configure your alternative control system.
Failsafe
If the SMART-R receiver fails to receive a signal from the controller for 60 minutes it will turn off the heater until a
signal is received again. Always ensure your controller and XLS panels are within range of each other.
Pairing SMART-R to an XLS controller
ENGLISH
Select XLS
General
Please note it is possible the heater may discolour with use this is caused by airborne pollution and is
not a fault.
The heater is designed to last many years and incorporates several safety features, but if the heater has
not been used or installed in adherence to these instructions, emits any noise, smell, or shows rapid
discolouration of the surface, discontinue using the heater and refer to Herschel Customer Service or
your local Herschel dealer.
The Herschel panel must be installed, uninstalled, cleaned or transported only when cold.
Painting
The Select XLS White panels can be painted to match décor using a suitable heat resistant paint.
However, Herschel will not be responsible if the paint deteriorates or discolours. Any rights to return the
heater for a refund within statutory periods will be voided where the heater has been painted. Painting
the panel will not affect your warranty for repair or replacement.
Cleaning and maintenance
Cleaning
Before attempting to clean the panel, unplug the heater, isolate the unit from the electrical supply and
allow it to completely cool down.
DO NOT immerse the Herschel panel heater in water or splash water onto it.
Clean the heater with a damp cloth. For glass models glass cleaner can be used. Never use a wet cloth.
When clean, dry the surfaces with a dry cloth.
DO NOT apply abrasive materials, solvents or solvent wipes to the surface as this can cause irreparable
damage. Wait until the unit is completely dry before use.
Repair
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit, doing so will void
your warranty. Repairs must only be carried out by Herschel or an authorised Herschel service partner.
Disposal
The heater is an electrical product and must not be disposed of in household waste. A high percentage
of the heater can be recycled. Please treat as electrical waste and recycle in accordance with local
regulations.
ENGLISH
Select XLS
Save energy
Most people are comfortable in living areas at around 19c with infrared but it varies person to person.
Take time to experiment and get used to your system and the temperatures you are happy with. The
lower you set your thermostat, the less electricity you will use.
Only heat the rooms that you use. Spare rooms can be heated to much lower temperatures and boosted
when people will be occupying them.
Living areas such as living room and kitchen should be heated differently to bedrooms and bathrooms.
Living areas are suited to a more constant heating schedule. Bedrooms are usually better to be heated
quickly and let to cool down again during the day. Set your controllers to fit with your lifestyle and make
the most of the 7 day program function you might have different heating requirements and times on
weekdays to weekends.
Getting the most from your Herschel heater top tips
Don’t over heat your room and take time to let the system work
Infrared is different to conventional heating. Because all of the energy from the heater is absorbed by the
room and the objects in it (we call it the “thermal mass”), it takes time for the thermal mass to warm up.
It’s only once the room itself is warm that you will feel warm. The great thing is that this heat is retained
longer and only needs topping up to account for the heat loss escaping from the room. In the longer term
you will use less energy than convection heating. At the start of the heating season or when your room
has cooled a lot the heater may be running for longer periods and could take several days to warm up.
Don’t make the mistake of increasing the temperature on the controller more than you want it to be it
won’t heat the room any quicker but will waste energy by overheating the room.
Go Carbon Zero
If you’ve not already done so, switch your energy supplier to a100% renewable tariff. It’s probably the
easiest and quickest thing you can do to reduce your Co2 emissions.
Don’t underspecify your heater requirements
Herschel is lower energy heating but it’s not magic and if you try to heat a room with an undersized heater
you’ll just end up cold and wasting energy and money. Ensure you have the correct sized heater(s) for the
room and if in any doubt consult the website, your local dealer or contact us.
And lastly.. tell your friends
You’ll soon be wondering what life was like in the bad old days before you got your Herschel heaters.
Don’t keep it to yourself! Share your photos and spread the word on social media to help others to move
off their fossil fuel based and inefficient heating systems!
ENGLISH
Select XLS
Register your product her https://www.herschel-infrared.co.uk/customer-service/warranty-registration/ .
Within five years from date of purchase Herschel will repair or replace the heater where the fault is due to defects
in materials or workmanship. This warranty is for standard domestic use only and excludes commercial uses. In the
event of a warranty claim please visit the Customer Service area of the Herschel Website and follow the Warranty
Claim process. You will need proof of purchase and photographs of the heater.
A prerequisite for validity of the warranty is use at the specified supply voltage of the heater and use in accordance
with the conditions specified in this manual. Any further warranty or claims are excluded.
The warranty covers the repair or replacement of the defective product only and Herschel shall have no liability for
installation costs or consequential loses however incurred. The decision to repair or replace will rest solely with
Herschel and any replacement will be as close as possible in specification to the failed heater.
Removing the serial number will void the warranty. The warranty will also be void if the heater has been tampered
with or opened in any way.
The product power label must be left on the panels where they can be accessed after installation if necessary.
Herschel Infrared Ltd will assume no responsibility for scratches on surface or frames after first use.
Disclaimer
Herschel Infrared Ltd cannot accept responsibility for damage, loss or injury caused by ingress of water or moisture,
accidental damage, mishandling, external impact, adjustment by unauthorised personnel or failure to follow the
correct maintenance and safety precautions as stated in the manual. Refer to Herschel Infrared Ltd’s warranty
policy for full details. See https://www.herschel-infrared.co.uk.
5 Year Warranty
ENGLISH
Select XLS
Herschel Easy-fix mounting system
Assembly Kit
Please check the enclosed assembly kit consists of:
1 x mounting bracket,
4x screws,
4x rawlplugs
Preparation Important Notice
When the EasyFix bracket is fitted to the panel, it will be offset from centre due to the locking movement. To
ensure your panel fits exactly where you want it on the wall or ceiling (white panels only), it is important
before installing that you place the bracket on the panel in its locked position and measure the distance of the
mounting holes to the edges of the panel before then marking, checking and drilling them on the wall (or
ceiling) to cater for this offset.
Step 1
Use a spirit level to ensure the bracket is level and
mark the position for drilling in each of the small
holes in the four corners of the mounting bracket
(figures 1 & 2).
Step 2
Drill holes using a 8mm drill. Insert the supplied
rawlplugs (see figure 3). If mounting on to a cavity wall
or ceiling you will need appropriate fixings (not
supplied).
Step 3
Screw the mounting bracket to the wall using the
supplied screws (figure 4).
Step 4
Fit the panel to the wall by locating all four mounting
fixings on the rear of the panel into the wide openings
on the mounting bracket. Once in position the panel
should be moved to the right and then down and to the
right again to its secure position (portrait mounting) or
down, then left and then down again (landscape
mounting) (fig 5 & 6).
Step 5 (Mirrors & Glass panels only)
Unscrew the four distance pieces (in each corner) on the rear of the heater panel so that the panel is held
tightly in its mounting on the wall and cannot be moved. Ensure the power lead is free from any obstruction
behind the panel.
Removal
Herschel Easy-fix is designed to be secure to avoid accidental dismounting or tampering with the panel. To
dismount the panel, screw the four distance pieces back in and move the panel to the left, then up and
over to the left again (portrait mounting) or up, then to the right and then up again (landscape mounting).
NOTE: If mounting larger panels (600w upwards) to a ceiling, use suitably rated fixing screws/mechanism
for the weight of the panel. Use the additional 2 fixing holes on the Easy-Fix mounting plate and fix to a
joist wherever possible. 2 people may be needed to mount the larger panels.
IMPORTANT
Glass and mirror panels are not designed for ceiling
mounting and there is a risk of overheating and glass
shattering or shortening of the panel lifespan. Do not
ceiling mount glass or mirror panels.
ENGLISH
Select XLS
ECODESIGN Information for Select XLS when used with XLS Controllers
When installed as fixed Electric Space Heaters
Applies to ALL models covered by these instructions.
Seasonal space heating energy efficiency pre Lot 20 =30%
Target efficiency target post Lot 20 =38%
Actual efficiency post Lot 20 =40%
All Herschel Select XLS Panels are “best in class” if used with Herschel XLS Controls.
Technical Details
Nominal heat output (Pnom) = Rated Wattage of heater (see product label)
Maximum continuous heat output (Pmax,c) = Rated Wattage of heater (see product label)
Type of control and efficiency gain
Electronic room temperature control plus week timer = 7%
Open Window Detection = 1%
Adaptive Start = 1%
Distance Control = 1%
When installed as a portable heater using Herschel Feet
Applies to Select XLS White panels only.
Seasonal space heating energy efficiency pre Lot 20 =30%
Target efficiency target post Lot 20 =36%
Actual efficiency target post Lot 20 =37%
Herschel Select XLS White Panels are compliant if used with a plugin electronic room temperature control such as Herschel T-PL.
Technical Details
Nominal heat output (Pnom) = Rated Wattage of heater (see product label)
Maximum continuous heat output (Pmax,c) = Rated Wattage of heater (see product label)
Type of control and efficiency gain
Electronic room temperature control = 7%
When used as a portable heater, the Select XLS White is only suitable for well insulated spaces or occasional use.
All Herschel Select XLS heaters when used with Herschel XLS controllers demonstrate best-in-class performance by
exceeding EcoDesign (Lot 20) requirements.
Herschel is not responsible for any breach of the legislation where the Select XLS is used without the appropriate
Herschel XLS controller.
If used as a portable heater using Feet, the Select XLS White heater is only suitable for well insulated spaces or
occasional use close to the user. (Select XLS Mirrors and Towel heaters must not be used as portable heaters).
Compliance with Ecodesign directive 2009/125/EC
ENGLISH
Select XLS
PRÉCAUTIONS DE SÉCURITÉ IMPORTANTES
Le non-respect de ces instructions annulera la garantie.
Ne pas désassembler. Aucune pièce réparable par l'utilisateur à l'intérieur.
POUR RÉDUIRE LE RISQUE D'INCENDIE, DE CHOC ÉLECTRIQUE
OU DE BLESSURE
Cet appareil doit être débranché de sa source d'alimentation pendant les activités d'installation ou d'entretien et
lors du remplacement.
Le Select XLS est équipé de SMART-R (situé à l'arrière du panneau), qui doit être associé à un contrôleur Herschel
XLS (vendu séparément) pour contrôler la température ambiante. Si vous n'utilisez pas un contrôleur Herschel XLS
ou un contrôleur de température ambiante similaire, NE PAS utiliser pour le chauffage des pièces lorsque les
pièces sont occupées par des personnes incapables de quitter la pièce par elles-mêmes, à moins qu'une
surveillance constante ne soit fournie. Herschel n'est pas responsable de toute violation de la législation sur
l'écoconception (lot 20)ou la sécurité lorsque les appareils de chauffage sont utilisés dans un espace clos sans
l'utilisation d'un Herschel XLS ou d'un contrôleur similaire.
Le Select XLS est doté de capteurs de sécurité thermique internes. Cependant, afin d'éviter une surchauffe et un
risque d'incendie potentiel, NE couvrez en aucun cas l'appareil de chauffage. NE PAS placer le radiateur à moins
de 0,3 m de tout matériau inflammable (par ex. meubles, rideaux).
NE PAS toucher le radiateur lorsqu'il est en cours d'utilisation. Les panneaux chauffants Herschel ont une
température de surface d'environ 95 °C / 248 °F (selon la tension d'entrée) et un contact prolongé avec le radiateur
provoquera des brûlures et des blessures.
NE PAS faire fonctionner le radiateur si le cordon ou la fiche est endommagé ou après un dysfonctionnement du
radiateur, ou s'il est tombé ou endommagé de quelque manière que ce soit. Vérifiez que chaque appareil de
chauffage n'est pas endommagé avant l'installation. Assurez-vous que le radiateur lui-même, la fiche (le cas
échéant) et le câble ne présentent aucun signe visible de dommage. Si le cordon est endommagé, l'appareil doit
être envoyé pour réparation à un revendeur Herschel agréé.
Cet appareil de chauffage ne doit être utilisé que pour le chauffage de personnes ou de bâtiments. L'appareil de
chauffage ne doit pas être utilisé par des enfants ou des personnes ayant des capacités physiques, sensorielles ou
mentales réduites, ou un manque d'expérience ou de connaissances. Les enfants doivent être tenus à l'écart et ne
doivent pas être laissés sans surveillance autour de l'unité. NE PAS utiliser à l'extérieur.
Tous les opérateurs ne doivent allumer/éteindre l'appareil que s'il a été placé ou installé dans sa position de
fonctionnement prévue conformément à ces instructions. Les enfants ne doivent pas brancher, allumer ou régler
l'appareil ou effectuer l'entretien par l'utilisateur, y compris le nettoyage.
Les panneaux Herschel sont conçus pour être utilisés avec une tension alternative comprise entre 220 et 240 volts,
50 Hz AC.Si votre tension d'alimentation dépasse 240 volts, n'utilisez pas le radiateur et consultez votre revendeur
local. Le non-respect de cette consigne annulera la garantie.
L'appareil de chauffage doit être monté sur une surface non inflammable.
PROTECTION CONTRE L'EAU IP44
Les panneaux chauffants Herschel Select XLS sont classés selon une norme (minimum IP44) leur permettant d'être
situés dans la zone 2 d'une salle de bain. Cela signifie qu'ils peuvent être placés au-dessus d'un évier ou à l'extérieur
de toute zone d'éclaboussure, ou ils peuvent être installés au plafond. Ils ne peuvent pas être installés dans les
zones 0 ou 1.
Cependant, l'installation dans des pièces potentiellement mouillées ou humides telles que les salles de bains doit
être effectuée par un installateur qualifié et conforme aux exigences locales de sécurité électrique. L'installation
doit être telle que le radiateur ne doit pas pouvoir se détacher des raccords et tomber dans une baignoire, une
douche, une piscine ou un autre réservoir d'eau et que les interrupteurs et autres commandes ne doivent pas être
touchés par une personne dans la baignoire ou la douche.
En cas de doute, n'installez pas. Herschel Infrared Ltd ne sera pas responsable des pertes, dommages ou blessures
causés ou résultant d'un montage inadéquat ou d'un placement incorrect des appareils de chauffage à proximité
de sources d'eau.
ATTENTION
FRANÇAIS
Select XLS
Merci d'avoir acheté un radiateur infrarouge Herschel Select XLS. Incorporant le tout dernier contrôle avec le
système SMART-R de Herschel, le montage EASYFIX et la conception mince sans cadre, vous profiterez de
nombreuses années de chauffage à faible consommation d'énergie, intelligent et confortable.
Nous avons essayé de rendre l'installation et l'utilisation de votre appareil de chauffage aussi simple que possible.
Veuillez lire ces instructions dans leur intégralité et les conserver pour référence future. Si vous avez des questions,
notre site Web contient également de nombreuses FAQ ou si vous pouvez nous appeler, envoyer un message ou
discuter en ligne avec nous, nous sommes toujours heureux de vous aider à tirer le meilleur parti de votre nouveau
système de chauffage Herschel.
Le Select XLS est un panneau chauffant infrarouge. Il
chauffe en transférant l'énergie directement du
radiateur dans la pièce et son contenu. Placez le
radiateur il ne sera pas immédiatement obstrué
par des objets comme des meubles ou il ne
peut pas rayonner efficacement, comme au bord ou
dans les coins d'une pièce. Les gros objets placés
devant le radiateur chaufferont et peuvent empêcher
une dispersion efficace de la chaleur dans la pièce. Si
vous le pouvez, évitez de placer le radiateur en face
des fenêtres, des portes ouvertes ou derrière des
meubles.
Selon la taille du radiateur, vous pourrez
probablement ressentir la douce chaleur du radiateur
jusqu'à environ 3 m de distance, mais il continuera à
émettre de la chaleur au-delà. Lorsque vous
choisissez une position de montage, déterminez si
vous souhaitez ressentir directement la chaleur (par
exemple au-dessus d'un canapé) ou non. Plus vous
êtes proche du radiateur, plus l'intensité de la
chaleur que vous ressentirez sera élevée. Cela
dépend généralement de vos préférences
personnelles.
La chaleur infrarouge se dispersera de la même
manière que la lumière d'un panneau lumineux à
LED. Si vous installez plusieurs panneaux dans une
pièce, essayez d'imaginer que chaque panneau est
une lumière et réfléchissez à la façon dont la lumière
« éclairera » la pièce vos radiateurs chaufferont la
pièce de la même manière.
Positionnement
Les panneaux blancs XLS peuvent être montés sur des plafonds, des murs ou portables.
Les Sèche-serviettes XLS et les Miroirs sont à montage mural uniquement.
FRANÇAIS
Select XLS
Les panneaux Select XLS White sont livrés avec une prise installée en usine. Ils peuvent être facilement fixés au mur
à proximité d'une prise électrique ou peuvent être autoportants. Les deux méthodes nécessitent l'utilisation des
commandes XLS (soit la commande enfichable T-PL ou la commande de batterie T-BT). Voir la section des
contrôles.
Options Plug and Play montage mural simple et portable (panneaux blancs
uniquement)
Montage mural
Fixez-le au mur à l'aide du support de montage EASYFIX et
branchez simplement le radiateur (s'applique uniquement aux
panneaux blancs fournis avec une prise adaptée).
C'est relativement simple pour un bricoleur compétent. Le
panneau devra être monté à proximité d'une prise électrique
mais NE DOIT PAS être monté immédiatement en dessous
d'une prise et à moins de 200 mm de la prise. La boîte SMART-
R à l'arrière du panneau doit être située au bas du panneau.
Le panneau peut être monté en position paysage ou portrait
(voir les instructions d'installation détaillées). Soyez prudent
lorsque vous percez des trous pour que le support de montage
EASYFIX soit exempt de câbles électriques dans les murs. En
cas de doute, n'installez pas et consultez un électricien
qualifié.
min 200mm
Utilisation autonome / portable
Les panneaux Select XLS White peuvent être utilisés de
manière autonome ou comme radiateurs portables, par
exemple pour le chauffage temporaire ou saisonnier. Pour
une utilisation portable, nous recommandons fortement
l'utilisation de Pieds Select XLS. Ceux-ci sont spécialement
conçus pour réduire le risque de renversement du radiateur et
pour empêcher le fond du radiateur d'être en contact direct
avec les surfaces du sol. Les pieds sont un accessoire et ne
sont pas fournis avec le radiateur. Contactez votre revendeur
ou le site Web Herschel pour plus de détails.
Certains miroirs et chauffe-serviettes XLS ne sont pas adaptés
àune utilisation portable. Ils sont fournis sans fiches et
doivent être fixés au mur et installés par un électricien
qualifié.
min 200mm
FRANÇAIS
Select XLS
Le montage du panneau au plafond donnera
généralement la meilleure dispersion de la chaleur
dans la pièce et gardera les espaces muraux libres.
Le montage au plafond n'est possible qu'avec des
panneaux blancs (sans verre). Le montage au
plafond nécessitera le retrait de la fiche et une
installation professionnelle et doit être effectué par
un électricien qualifié. Les panneaux plus grands de
800 Wet plus peuvent nécessiter deux personnes
pour une installation en toute sécurité.
La série Herschel Select XLS White peut être montée
sur la surface des plafonds à l'aide du support
EASYFIX fourni. Si vous encastrez des radiateurs
dans un plafond en plâtre, maintenez un
dégagement de 200 mm autour de tous les côtés du
radiateur et maintenez au moins 800 mm entre les
radiateurs adjacents. Les objets devant le panneau
doivent être à au moins 400 mm et 200 mm des
côtés. La distance par rapport aux côtés de l'appareil
de chauffage doit toujours être respectée. Le non-
respect de cette consigne entraînera une
accumulation de chaleur excessive derrière le
radiateur et annulera la garantie.
Certains panneaux XLS White sont également
équipés de points de montage de fil à l'arrière de
l'appareil de chauffage. Ces points de montage
peuvent être utilisés à la place du support EASYFIX
lorsqu'un montage au plafond suspendu est requis
(par exemple dans des pièces avec des plafonds
hauts/voûtés). Chaque fil de montage doit être
capable de supporter le poids du panneau
individuellement. Les kits de câbles de montage
appropriés sont un accessoire et ne sont pas fournis
avec l'appareil de chauffage. Contactez votre
revendeur Herschel pour plus de détails.
Montage au plafond panneaux blancs uniquement.
Installation professionnelle requise
min 200mm
Mur
Plafond
FRANÇAIS
Select XLS
ATTENTION
Le câblage de cet appareil doit être connecté conformément aux normes nationales de sécurité électrique
applicables. Il s'agit d'un appareil de classe 1 et doit être mis àla terre.
Lorsqu'elle est placée dans des espaces publics, l'installation doit être conforme aux normes électriques locales
applicables. Pour certains bâtiments publics comme les écoles et les maisons de retraite, les appareils de chauffage
doivent être installés conformément à la législation spécifique à ces types de bâtiments.
L'alimentation électrique de chaque appareil de chauffage doit être fournie en se connectant à un circuit protégé
par un fusible ou un dispositif à courant résiduel (RCD) ou un disjoncteur de fuite à la terre (GFCI) adapté à la
puissance électrique de l'appareil.
Code couleur utilisé dans le câble secteur fourni : le fil MARRON doit être connecté à LIVE L »), le fil BLEU au
NEUTRE N») et le fil VERT/JAUNE à la TERRE E»).
MISE EN GARDE
Assurez-vous que l'alimentation secteur est coupée avant de commencer une installation impliquant un câblage
fixe. Tout câblage fixe à l'extérieur de l'appareil de chauffage entrant en contact ou à proximité immédiate de
l'appareil de chauffage doit être protégé par un manchon avec une température nominale d'au moins 90 °C.
Tout le câblage derrière l'appareil doit emprunter le chemin le plus court jusqu'au bord du radiateur.
Assurez-vous que le câble d'alimentation n'est pas enroulé. Raccourcissez le câble d'alimentation si possible et ne
placez pas de câble en excès à l'arrière du radiateur.
Les connexions électriques ne doivent pas être effectuées derrière le radiateur, quelle que soit la position de
montage au mur ou au plafond.
L'appareil de chauffage ne doit pas être situé immédiatement en dessous d'une prise de courant, que ce soit au
mur ou au plafond.
NE PAS percer à travers le radiateur car cela causera des dommages irréparables et est également dangereux.
NE PAS connecter un radiateur endommagé de quelque manière que ce soit au réseau électrique.
Pour le montage du panneau Herschel, utilisez uniquement le matériel de montage fourni et installez-le
conformément au guide d'installation.
Le panneau peut être monté à l'aide du support de montage EASYFIX et «câblé » à l'alimentation électrique. Pour
la gamme de panneaux blancs, cela nécessitera le retrait de la fiche et la connexion à une boîte de connexion
appropriée placée à côté du radiateur. Cette méthode d'installation ne doit être effectuée que par un électricien
compétent. La boîte SMART-R à l'arrière du panneau doit être située au bas du panneau. Le panneau peut être
monté en position paysage ou portrait (voir les instructions d'installation détaillées).
Câblage fixe dans le secteur. Installation professionnelle requise
FRANÇAIS
Select XLS
Couplage du SMART-R à un contrôleur XLS
Le radiateur est équipé de notre récepteur SMART-R XLS intégré (situé à l'arrière du panneau).
Il y a un interrupteur marche/arrêt sur le récepteur et il y a des indicateurs pour montrer si le panneau est couplé à
un contrôleur et si le chauffage est allumé ou éteint.
Le radiateur doit être couplé à un contrôleur Herschel XLS (fourni séparément). Une fois appairé, il recevra les
commandes ON/OFF du contrôleur.
IMPORTANT : Le panneau lui-même n'a pas de capteur de température intégré. L'utilisation efficace de l'appareil de
chauffage n'est possible qu'en l'associant à un contrôleur XLS. Le récepteur SMART-R XLS ne s'apparie pas avec un
contrôleur XLS non-Herschel. SMART-R NE SERA PAS associé à une commande de la série Herschel iQ (T1ou Hub).
Les contrôleurs Herschel XLS peuvent être couplés et contrôler un ou plusieurs panneaux chauffants. La
température de la pièce sera mesurée par le contrôleur XLS. Il est normal d'utiliser un contrôleur par pièce, mais s'il
s'agit d'une grande pièce (telle qu'un espace ouvert), vous voudrez peut-être envisager plus d'un contrôleur de
thermostat. S'il y a plusieurs panneaux de chauffage par pièce, associez chaque panneau au contrôleur de pièce
approprié.
Fonctionnement utilisation avec les commandes XLS
Tous les panneaux Herschel Select XLS sont équipés d'un récepteur SMART-R XLS à l'arrière du panneau arrière.
SMART-R se couplera sans fil (via RF) avec les contrôleurs thermostatiques XLS. Le T-BT est un thermostat à piles. Le
contrôle Wi-Fi et APP n'est pas possible avec T-BT.
Pour le contrôle WiFI et APP, le T-PL est un contrôle de thermostat simple à utiliser qui se branche sur une prise
secteur. Ils sont parfaits pour les rénovations et les solutions de chauffage portables.
Pour les nouvelles constructions et les rénovations, choisissez le thermostat T-MT câblé sur secteur qui est
compatible WiFi.
Toutes les options de contrôle peuvent être associées au SMART-R. Le contrôleur envoie ensuite des commandes
pour allumer ou éteindre le chauffage en fonction de la température ambiante et du programme.
Assurez-vous de suivre attentivement les instructions d'appairage. Une aide en ligne est également disponible via la
section Aide et support de votre site Web Herschel local.
SMART-R
T-BT
T-MT
T-PL
(aucun WiFi)
FRANÇAIS
Select XLS
Les fonctions SMART-R à l'arrière du panneau sont
1 LED d'état d'appairage (verte)
2 LED d'état du chauffage (rouge)
3 Bouton « Appairage »
4 Interrupteur d'alimentation
Nous vous recommandons de brancher l'unité et de coupler le
SMART-R à votre contrôleur XLS avant de monter le panneau.
Étape 1
Branchez votre radiateur sur une prise électrique. Mettez l'interrupteur d'alimentation (4) sur « On » .
Appuyez deux fois sur le bouton « Appairage » (3) du SMART-R. La LED d'état d'appairage (1) commencera à
clignoter.
Étape 2
Reportez-vous aux guides d'appairage de la manette XLS de votre choix pour connaître les étapes d'appairage sur
ces appareils.
La LED d'état de jumelage (1) s'arrêtera de clignoter sur le récepteur du panneau une fois le jumelage terminé et
s'allumera en vert fixe.
REMARQUE : L'interrupteur d'alimentation (4) devra être en position ON pour recevoir les commandes du
contrôleur et doit être laissé en position ON, me lorsqu'il n'est pas utilisé. Le panneau ne fonctionnera pas si
l'interrupteur d'alimentation est sur OFF. Dans le cas un panneau ne chauffe pas lorsque cela est nécessaire,
vérifiez d'abord que l'interrupteur d'alimentation (4) est en position ON. L'appareil de chauffage est destiné à être
allumé ou éteint par le contrôleur Herschel XLS, l'interrupteur d'alimentation (4) n'étant qu'une dérogation.
Contournement du contrôleur
Le panneau Select XLS peut être configuré pour contourner le récepteur dans les cas un système de contrôle
alternatif est destiné à être utilisé (par exemple, un système de gestion de bâtiment). Dans cette configuration, le
panneau est connecté directement au réseau électrique et contrôlé (allumé ou éteint) par le système de contrôle
alternatif. Tout système de contrôle alternatif devra répondre aux exigences du LOT 20 afin d'assurer la conformité
(veuillez consulter votre revendeur). Utilisez cette fonction de dérivation si vous câblez le panneau à un contrôleur
alternatif (non XLS).
NE PAS faire fonctionner le panneau Select XLS en état de dérivation sans l'utilisation d'un contrôleur externe. Cela
gaspillera de l'énergie et est contraire à la législation sur l'écoconception (lot 20)et la sécurité.
Pour contourner le récepteur, avec l'interrupteur d'alimentation (4) sur « ON », appuyez longuement sur le bouton
« Pairing » (3) jusqu'à ce que la LED d'état d'appairage (1) s'éteigne et que la LED d'état de chauffage (2) reste
allumée (rouge) . Suivez les instructions du fabricant pour configurer votre système de contrôle alternatif.
Sécurité intégrée
Si le récepteur SMART-R ne reçoit pas de signal du contrôleur pendant 60 minutes, il éteint le radiateur jusqu'à ce
qu'un signal soit à nouveau reçu. Assurez-vous toujours que votre contrôleur et les panneaux XLS sont à portée l'un
de l'autre.
Couplage du SMART-R à un contrôleur XLS
FRANÇAIS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73

Herschel XLS300W Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per