4.4. USING THE DISCS
The device is supplied with the ejector fitted to the
drive spindle. Release the cover lock and lift the
cover to remove the ejector (see figure. 1)
Before starting work always check the cleanliness
of the cutting chamber, the drive spindle, the ejec-
tor and the cutting discs.
1) Slicing, shredding and grating
• Mount the ejector onto the flat surface of the
drive spindle.
• Mount the required disc (slicing, shredding or
other – options.
- Turn the dics clockwise to insert the bayonet
and keep on turning closwise until it reaches
the pin.
- To remove the disc, turn it in the opposite di-
rection and lift it using the finger holes at the
edges of the disc.
- Close and lock the cover.
2) Cutting into chips or cubes (option)
• Mount the ejector.
• Mount the chips/dice disc in the housing and
check for correct fixing (the assembly area
must be clean). The upper edge of the chips/
dice disc must be placed slightly below the top
of the body of the device.
• Then mount the slicing disc of the same size as
the chips/dice disc and close the cover.
5. CLEANING AND MAINTENANCE OPERATIONS
5.1. GENERAL INFORMATION AND PRODUCTS USED FOR CLEANING
Before carrying out any cleaning or maintenance
operations, check if the mains switch is off and the
plug is disconnected from the mains.
Clean the device and the discs thoroughly every
day to ensure correct operation and long life of the
device.
The cutting discs and the ejector can be cleaned
with a warm water jet.
Clean the device, in particular the disc assembly,
only with a cloth or a sponge damped in warm wa-
ter. Thoroughly remove all remaining foodstuff to
prevent the discs from changing their position.
Open the cover and loosen pin 1 as shown in figure
no.3. Remove the cover and wash with warm run-
ning water.
Clean the surfaces with water with soap, alcohol,
non-abrasive detergents or with water without
chlorine- or soda-based substances (chlorinated
water, hydrochloric acid).
Never use abrasives, steel wool or similar products
as they may damage the surface, coating or body
of the device.
For cleaning use non-toxic hygiene products.
figure no. 3
5.2. IN CASE OF FAILURE
When the white pilot light on the panel is on and the
device does not start, check if the handle and the
cover are closed. Safety microswitches are activat-
ed this way. The safety microswitches prevent the
machine start if the securities are not activated.
In case of failure, unplug the device and call the
maintenance service or qualified personnel.
Do not start the device or attempt self-repairs.