USE & CARE INSTRUCTIONS for BrewWISE
SM
System
(Includes G92T DBC Grinder and DUAL SH DBC Brewer with Smart Funnel™)
STEP 1
STEP 2 STEP 3 STEP 4
34481.0000C 03/17 ©2003 Bunn-O-Matic Corporation
34481 011403
Select the desired batch
size and coffee flavor on
the grinder. It is not nec-
essary to select a size on
the brewer.
Discard the grounds and
filter when brewing is
completed.
Momentarily press and
release the BREW button.
Place an empty server
under the funnel.
Slide funnel into the fun-
nel rails. The brewer reads
the batch size and flavor
ground through a chip in
the funnel handle and will
automatically select the
correct settings to brew.
Grind the proper amount of
fresh coffee into the Smart
Funnel™ using the G92-
HD with Smart Funnel™
operation.
Insert a BUNN
®
filter into
the funnel.
A batch size must be cho-
sen at the brewer when
grounds are not obtained
from a Smart Funnel™
compatible grinder.
STEP 5
STEP 6 STEP 7
STEP 8
STEP 9 STEP 10
Level grounds by gently
shaking.
Press the ON/OFF button
to ON.
STEP 2
STEP 4
Clean mineral deposits
and rinse. Using a paper
clip, make sure all holes
are open.
STEP 1
Remove the sprayhead.
STEP 5
Use a clean damp cloth
rinsed in nonabrasive,
mild detergent to clean all
surfaces.
Remove the lid of the
server.
STEP 3
Reinstall the sprayhead.
CLEANING
COFFEE BREWING
34481 031617
STEP 6
STEP 8STEP 7 STEP 9 STEP 10
STEP 12 STEP 14STEP 11 STEP 15
Unscrew the inlet cap.
Pull out lid assembly.
Clean inlet tube with the
medium sized brush
(BOM #00675.0000) and
cleaning product solution.
Rinse well. Reassemble
the lid making sure to
replace the retainer cap.
Clean the sight gauge with
the small brush (BOM
#00674.0000) and reas-
semble.
Remove the glass tube.
Make sure reservoir is
empty and unscrew the
sight gauge cap.
Use a clean damp cloth
rinsed in nonabrasive,
mild detergent to clean all
surfaces.
Thoroughly rinse entire
inside of the server. DO
NOT immerse server in
water.
STEP 13
Reinstall glass tube and
the sight gauge cap.
Use a small brush (BOM
#00674.0000) to thor-
oughly scrub the faucet
shank.
Allow the parts to soak in
a sanitizer solution for a
minimum of ten minutes.
Remove the faucet parts
from the sanitizer solution.
Allow parts to air-dry
overnight.
Transfer these parts to a
three compartment sink
for cleaning. Fill the first
sink with a soap solution
using a mild detergent,
the second sink is used for
clean rinse and the third
sink is used for a sanitizer
solution (75°F warm
non-chlorine sanitizing
solution).
STEP 16
STEP 17 STEP 18 STEP 19 STEP 20
Turn the faucet wing nut in
a clockwise direction and
remove the faucet from
the dispenser. Unscrew
the faucet cap from the
faucet body and disas-
semble all faucet parts.
Use a small brush (BOM
#00674.0000) to thor-
oughly scrub the faucet
body.
CLEANING (Continued)
USE & CARE INSTRUCTIONS for BrewWISE
SM
System
(Includes G92T DBC Grinder and DUAL SH DBC Brewer with Smart Funnel™)
  • Page 1 1
  • Page 2 2