Wolf ICBSRT364C-LP Manuale utente

Categoria
Fornelli
Tipo
Manuale utente
SEALED BURNER RANGETOPS
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACIÓN
INSTRUCTIONS D’INSTALLATION
ISTRUZIONI PER L’INSTALLAZIONE
INSTALLATIONSANWEISUNGEN
33
ENGLISH 4
ESPÃNOL 18
FRANÇAIS 32
ITALIANO 46
DEUTSCH 60
As you follow these instruc tions, you will
noticeWARNING and CAUTION symbols. This
blocked information is impor tant for the safe
and efficient installation of Wolf equipment.
There are two types of potential hazards that
may occur during installation.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights informa-
tion that is especially relevant to a problem-
free installation.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
WOLF
®
is a registered trademark of Wolf Appliance, Inc.
CONTACT
INFORMATION
Website:
wolfappliance.com
5
WOLF SEALED BURNER RANGETOP
INSTALLATION REQUIREMENTS
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
IMPORTANT NOTE:
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Do not store or use gasoline or
other flammable vapors and liquids
in the vicinity of this or any other
appliance.
The use of a gas cooking appliance
results in the production of heat and
moisture in the room in which it is
installed. Ensure that the kitchen is
well ventilated; keep natural ventila-
tion holes open or install a mechani-
cal ventilation device (mechanical
extractor hood)
Prolonged intensive use of the appli-
ance may for additional ventilation,
for example opening of a window,
or more effective ventilation, for
example increasing the level of
mechanical ventilation where
present.
This appliance shall be installed
in accordance with the regula-
tions in force and only used in a
well ventilated space. Read the
instructions before installing or
using this appliance.
6
WOLF SEALED BURNER RANGETOP
RATING PLATE
INFORMATION
Model Number
Serial Number
INSTALLATION REQUIREMENTS
IMPORTANT NOTE: This installation must
be completed by a qualified installer,
service agency or gas supplier.
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc-
tions prior to installation.
Installer:
please retain these instructions
for local inspector’s reference, then leave
them with the homeowner.
Homeowner:
please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
IMPORTANT NOTE:
This appliance must be
installed in accordance with local codes. The
correct voltage, frequency and amperage must
be supplied to the appliance from a dedicated,
grounded circuit which is protected by a
properly sized circuit breaker or time delay
fuse. The proper voltage, frequency, and
amperage ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the sealed rangetop. Both numbers
are listed on the rating plate, located on the
underside of the sealed rangetop. Refer to the
illustration below.
BEFORE YOU START
Proper installation is your responsibility.
Have a qualified technician install this
sealed rangetop. You must also assure that
electrical installation is adequate and in
compliance with all local codes and ordi-
nances.
Prior to installation, ensure that the local
distribution conditions (nature of the gas
and gas pressure) and the adjustment of
the appliance are compatible.
Proper gas supply connection must be
available; refer to Gas Supply Requirements
on page 12. Electrical ground is required;
see Electrical Requirements on page 15.
The adjustment conditions for this appli-
ance are stated on the label (or rating
plate). The data plate can be found on the
underside of the sealed rangetop.
Rating plate location
Location of rating plate
under control panel
7
INSTALLATION INSTRUCTIONS
BEFORE YOU START
Check the location where the rangetop will
be installed. The location should be away
from strong draft areas, such as windows,
doors and strong heating vents or fans. Do
not obstruct the flow of air. The area in
which you are installing this appliance must
have an adequate supply of fresh air to
ensure proper combustion and ventilation.
This appliance is not connected to a
combustion products evacuation device.
It shall be installed and connected in accor-
dance with current installation regulations.
Particular attention shall be given to the
relevant requirements regarding ventilation.
All openings in the wall where the rangetop
is to be installed must be sealed.
INSTALLATION SPECIFICATIONS
Wolf sealed burner rangetops come in
762 mm, 914 mm and 1219 mm widths. Illus-
trations on pages 9–11 provide the overall
dimensions and installation specifications for
each width of sealed burner rangetop.
Each rangetop is designed to fit between
cabinets set at the distance specified by the
unit. For example, a 914 mm rangetop will fit a
914 mm opening.
IMPORTANT NOTE:
Cabinet opening dimen-
sions shown in the Installation Specifications
illustrations must be used. These dimensions
provide for required clearances.
IMPORTANT NOTE:
Locate the electrical
supply within dimensions shown in the
Installation Specifications illustrations.
Refer to the Installation Specifications illustra-
tion for your model on pages 9–11 for the
exact rough opening dimensions and location
of the gas and electrical supply.
ISLAND | PENINSULA INSTALLATIONS
Minimum clearances to combustible
surfaces:
Island Installations: Minimum 305 mm
clearance to rear wall that rises above the
countertop.
Peninsula Installations: Minimum 152 mm
clearance to side walls and minimum
305 mm clearance to rear wall that rises
above the countertop.
Refer to the Installation Specifications
illustration for your model on pages 9–11
for the exact rough opening dimensions.
8
WOLF SEALED BURNER RANGETOP
MINIMUM CLEARANCES
IMPORTANT NOTE:
Caution must be used
in planning the proper installation of the Wolf
sealed burner rangetop to avoid fire or
damage to adjacent cabinetry or kitchen
equipment. Be sure to follow the minimum
clearances established in the finished rough
opening dimensions.
Refer to the Installation Specifications
illustration for your model on pages 9–11
for the exact rough opening dimensions.
WALL INSTALLATIONS
Minimum clearances to combustible
surfaces:
Minimum 457 mm clearance from bottom
of upper cabinet to countertop, within
152 mm minimum side clearance.
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the rangetop. The
maximum depth of overhead and side
cabinets is 330 mm, within 152 mm side
clearance.
0 mm clearance for adjacent combustible
materials below the countertop, both sides
and rear.
Bottom of ventilation hood must be
762 mm minimum to 914 mm maximum
from countertop.
Minimum clearances for sealed burner
rangetops without a ventilation hood:
Model ICBSRT304: 762 mm minimum
vertical distance from countertop to
combustible materials above the rangetop.
All Other Sealed Burner Rangetops:
Surface Burners or Griddle (G) Models:
914 mm minimum vertical distance from
countertop to combustible materials above
the rangetop.
Charbroiler (C) Models: 1118 mm minimum
vertical distance from countertop to
combustible materials above the rangetop.
Failure to locate the rangetop without
the proper clearances will result in a fire
hazard.
RISER REQUIREMENTS
Installations against a combustible surface:
Model ICBSRT304: No riser requirements.
914 mm Sealed Burner Rangetops: A
minimum 254 mm riser is required for all
charbroiler (C) or griddle (G) models
installed against a combustible surface.
1219 mm Sealed Burner Rangetops: A
minimum 254 mm riser is required for all
charbroiler (C) or griddle (G) models
installed against a combustible surface.
9
INSTALLATION INSTRUCTIONS
VENTILATION
HOOD
762 mm
OPENING WIDTH
762 mm min
TO
914 mm max
TO BOTTOM OF
VENTILATION HOOD
762 mm min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
19 mm
PLATFORM
TOP VIEW
OF PLATFORM
E
G
406 mm
406 mm
102 mm
BACK
WALL
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0 mm TO NON-COMBUSTIBLE MATERIALS
LOCATION OF GAS AND
ELECTRICAL SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
914 mm
457 mm min
TO COUNTERTOP
19 mm
PLATFORM
216
mm
COOKING
SURFACE
191 mm
610 mm
330 mm
max
152 mm min
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
759 mm
OVERALL WIDTH
616 mm
318
mm
WITH
127 mm
RISER
445
mm
WITH
254 mm
RISER
699
mm
WITH
508 mm
RISER
724 mm
OVERALL DEPTH
216 mm
OVERALL
HEIGHT
COOKING
SURFACE
191
mm
235
mm
INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
Overall Width 759 mm
Overall Height
(to cooking surface) 216 mm
Overall Depth 724 mm
Opening Width 762 mm
Dimensions may vary to
±
3 mm.
762 mm SEALED BURNER RANGETOP
10
WOLF SEALED BURNER RANGETOP
VENTILATION HOOD
914 mm
FINISHED ROUGH OPENING WIDTH
762 mm min TO
914 mm max
TO BOTTOM OF
VENTILATION HOOD
914 mm min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
1118 mm min
FOR CHARBROILER
19 mm
PLATFORM
TOP VIEW
OF PLATFORM
E
G
406 mm
406 mm
102 mm
BACK
WALL
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0 mm TO NON-COMBUSTIBLE MATERIALS
LOCATION OF GAS AND
ELECTRICAL SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
914 mm
457 mm min
TO COUNTERTOP
19 mm
PLATFORM
216
mm
COOKING
SURFACE
191 mm
610 mm
330 mm
max
152 mm min
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
911 mm
OVERALL WIDTH
616 mm
724 mm
OVERALL DEPTH
216 mm
OVERALL
HEIGHT
COOKING
SURFACE
191
mm
235
mm
445
mm
WITH
254 mm
RISER
699
mm
WITH
508 mm
RISER
INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
Overall Width 911 mm
Overall Height
(to cooking surface) 216 mm
Overall Depth 724 mm
Opening Width 914 mm
Dimensions may vary to
±
3 mm.
914 mm SEALED BURNER RANGETOP
IMPORTANT NOTE:
A minimum 254 mm
riser is required for
all charbroiler (C) or
griddle (G) models
installed against a
combustible surface.
11
INSTALLATION INSTRUCTIONS
VENTILATION HOOD
1219 mm
FINISHED ROUGH OPENING WIDTH
762 mm min TO
914 mm max
TO BOTTOM OF
VENTILATION HOOD
914 mm min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
1118 mm min
FOR CHARBROILER
LOCATION OF GAS AND
ELECTRICAL SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
19 mm PLATFORM
TOP VIEW
OF PLATFORM
E
G
406 mm
406 mm
102 mm
BACK
WALL
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0 mm TO NON-COMBUSTIBLE MATERIALS
914 mm
457 mm min
TO COUNTERTOP
19 mm
PLATFORM
216
mm
COOKING
SURFACE
191 mm
610 mm
330 mm
max
152 mm min
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
1216 mm
OVERALL WIDTH
616 mm
724 mm
OVERALL DEPTH
216 mm
OVERALL
HEIGHT
COOKING
SURFACE
191
mm
235
mm
318
mm
WITH
127 mm
RISER
445
mm
WITH
254 mm
RISER
699
mm
WITH
508 mm
RISER
INSTALLATION SPECIFICATIONS
OVERALL DIMENSIONS
Overall Width 1216 mm
Overall Height
(to cooking surface) 216 mm
Overall Depth 724 mm
Opening Width 1219 mm
Dimensions may vary to
±
3 mm.
1219 mm SEALED BURNER RANGETOP
IMPORTANT NOTE:
For 1219 mm sealed
burner rangetops,
a minimum 254 mm
riser is required for
all charbroiler (C) or
griddle (G) models
installed against a
combustible surface.
12
WOLF SEALED BURNER RANGETOP
IMPORTANT
NOTE
This installation
must conform with
local codes and
ordinances.
INSTALL THE RANGETOP
Prepare the finished rough opening for the
rangetop according to the Installation Specifi-
cations illustration for your model on pages
9–11. The platform must be 19 mm thick and
include a cut-out at the right rear for gas
supply and electrical connections.
IMPORTANT NOTE:
The platform must be
level to ensure that the cooking surface is
level.
Remove and discard all packing materials,
including cardboard and tape on the outside of
the rangetop. Remove the burner grates and
styrofoam off the top cooking surface. Be
sure to remove the burner caps packaged in
styrofoam below the burner grates.
If your installation requires a riser, it must be
attached to the rangetop before installation.
Refer to the installation instructions packaged
with the riser.
Position the rangetop on the platform. Gas
supply and electrical connections should be
made before the rangetop is placed in its final
position.
IMPORTANT NOTE:
The sealed rangetop must
be connected to a regulated gas supply.
IMPORTANT NOTE:
This installation must
conform with local codes and ordinances.
The rating plate, located on the underside of
the burner box, has information on the type of
gas that should be used. If this information
does not agree with the type of gas available,
check with the local gas supplier.
An ISO 7-1 gas inlet thread is provided on all
units. Please contact your local Wolf dealer if
an ISO 228-1 or other gas inlet thread is
required. Pipe joint compounds, suitable for
use with LP gas should be used. LP gas suppli-
ers usually determine the size and materials
used on the system.
If local codes permit, a flexible metal appliance
connector is recommended for connecting this
sealed rangetop to the gas supply line. Do not
kink or damage the flexible connector when
moving the sealed rangetop. You will need to
determine the fittings required, depending on
the size of your gas supply line, flexible metal
connector and shut-off valve.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the sealed
rangetop. All strains must be removed from
the supply and gas lines so the sealed
rangetop will be level and in line.
EXPLOSION HAZARD
Securely tighten all external gas
connections.
Failure to do so can result in explosion,
fire or death.
GAS SUPPLY REQUIREMENTS
13
INSTALLATION INSTRUCTIONS
GAS RATING
Total Heat Electrical Types and
Output Gas Rating Appliance Pressures
Model # (Gas) Units (Amps) Category (mbar) Country of Destination
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT304 16.6 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT304-LP 1037 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT364C 22.4 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT364C-LP 1415 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT364G 22.1 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT364G-LP 1373 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT486C 31.6 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT486C-LP 1987 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT486G 31.3 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT486G-LP 1945 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT484CG 27.9 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT484CG-LP 1751 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBSRT484F 21.2 kW 0.17
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBSRT484F-LP 1323 g/h 0.17 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO,
PT, ES, GB, CH
GAS SUPPLY REQUIREMENTS
GAS LEAK TESTING
Use a brush and liquid detergent to test all gas
connections for leaks. Bubbles around connec-
tions will indicate a leak. If a leak appears, shut
off the gas valve and adjust connections. Then
check connections again. Clean all the deter-
gent solution from the rangetop.
14
WOLF SEALED BURNER RANGETOP
Never test for a gas leak with a match or
other flame.
15
INSTALLATION INSTRUCTIONS
ELECTRICAL REQUIREMENTS
ELECTRICAL SHOCK HAZARD
Plug into a grounded 3-prong adapter.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can
result in electric shock, fire or death.
RECOMMENDED GROUND METHOD
IMPORTANT NOTE:
For your personal safety,
this sealed rangetop must be grounded. This
sealed rangetop is equipped with a 3-prong
ground plug. To minimize possible shock
hazard, the cord must be plugged into a
mating 3-prong ground-type outlet, grounded
in conformance with all local codes and ordi-
nances. If a mating outlet is not available, it is
the obligation of the customer to have a
properly grounded, 3-prong outlet installed by
a qualified electrician.
IMPORTANT NOTE:
If product is connected to
a GFCI protected outlet, nuisance tripping of
power supply may occur, resulting in loss of
product operation.
WIRING DIAGRAM
The wiring diagram covering the electrical
circuit is located on the inside left wall of the
rangetop.
IMPORTANT NOTE:
If codes permit and a
separate ground wire is used, it is recom-
mended that a qualified electrician determine
that the ground path is adequate.
IMPORTANT NOTE:
Check with a qualified
electrician if you are not sure whether the
sealed rangetop is properly grounded.
IMPORTANT NOTE:
Do not ground to a gas
pipe.
A 220-240 VAC, 50/60 Hz, fused electrical
supply is required. A time-delay fuse or circuit
breaker is recommended. It is recommended
that a separate circuit serving only this appli-
ance be provided.
Electronic ignition systems operate within
wide voltage limits, but proper ground and
polarity are necessary. In addition to checking
that the outlet provides 220-240 VAC power
and is correctly grounded, the outlet must be
checked by a qualified electrician to see if it is
wired with correct polarity.
This appliance, when installed, must be electri-
cally grounded in accordance with local codes.
16
WOLF SEALED BURNER RANGETOP
SURFACE BURNERS
INITIAL LIGHTING
The surface burners use electronic igniters in
place of standing pilots. When the sealed
rangetop control knob is pushed in and turned
to the position, the system creates a spark
to light the burner. This sparking continues
until the electronic ignition senses a flame. If
the burner fails to ignite after 10 seconds,
return the knob to the position and attempt
to ignite by turning the knob back to the
position.
Be sure to place the burner heads and caps on
each burner base and position the burner
grates over the burner bases and heads before
lighting.
To check operation of the surface burners,
push in and turn each control knob to the
position. The flame should light within four
seconds.
If the burners do not light properly, turn
control knob to the position. Check that the
burner heads and caps are in the proper
position. Check that the power supply cord is
plugged in and that the circuit breaker or
house fuse has not blown. Check operation
again, if the burners do not light properly at
this point, contact a Wolf authorized service
center.
IMPORTANT NOTE:
Initial lighting of the
surface burners may take slightly longer, as air
in the system must be purged before gas can
be supplied to the burner.
SEALED RANGETOP REMOVAL
If it is necessary to remove the sealed
rangetop for cleaning or service, shut off the
gas supply. Disconnect the gas and electric
supply. Remove the mounting brackets on the
right and left side of the burner box and
remove the sealed rangetop. Reinstall in the
reverse order and check the gas connection for
leaks.
TROUBLESHOOTING
IMPORTANT NOTE:
If the sealed rangetop
does not operate properly, follow these trou-
bleshooting steps:
Verify that power is being supplied to the
sealed rangetop.
Check that gas valves are turned to the ON
position.
Check the gas supply and electrical
connections to ensure that the installation
has been completed correctly.
Follow troubleshooting procedures as
described in the Wolf Sealed Burner
Rangetops Use & Care Information.
If the sealed rangetop still does not work,
contact a Wolf authorized service center. Do
not attempt to repair the sealed rangetop
yourself. Wolf is not responsible for service
required to correct a faulty installation.
17
CONTACT
INFORMATION
Website:
wolfappliance.com
IF YOU NEED SERVICE
For service in your area, contact either your
Wolf dealer or visit the Showroom Locator
section of our website, wolfappliance.com
to find the regional distributor by country.
When calling for service, you will need the
sealed rangetop model and serial numbers.
Both numbers are listed on the rating plate,
located on the underside of the sealed
rangetop. Refer to the illustration on page 6
for location of the rating plate.
INSTALLATION INSTRUCTIONS
The information and images in this book are the
copyright property of Wolf Appliance, Inc., an
affiliate of Sub-Zero, Inc. Neither this book nor any
information or images contained herein may be
copied or used in whole or in part without the
express written permission of Wolf Appliance,
Inc.,an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
Cuando consulte las instrucciones que aparecen
en esta guía, encontrará símbolos de ADVER-
TENCIA y PRECAUCIÓN. Esta información en
recuadros es importante para instalar el equipo
de Wolf de forma segura y eficaz. Existen dos
tipos de posibles riesgos que pueden producirse
durante una instalación.
Otro tipo de anotación que es importante
resaltar es la que se incluye en NOTA
IMPORTANTE: En esta nota se resalta la
información que resulta especialmente
importante para que la instalación se
realice sin problemas.
PRECAUCIÓN
indica una situación en la que se pueden sufrir
heridas leves o provocar daños secundarios al
producto si no se siguen las instrucciones.
indica peligro de que se produzcan heridas
personales graves o incluso puede provocar
la muerte si no se siguen las precauciones
especificadas.
WOLF
®
es una marca comercial registrada de Wolf Appliance, Inc.
INFORMACIÓN
DE CONTACTO
Página Web:
www.sub-zero.eu.com
19
ENCIMERA DE COCCIÓN A GAS CON QUEMADORES HERMÉTICOS DE WOLF
REQUISITOS DE
INSTALACIÓN
QUÉ SE DEBE HACER SI HUELE A GAS:
No encienda ningún aparato.
No toque ningún interruptor
eléctrico.
No utilice ningún teléfono dentro
del edificio.
Llame inmediatamente a su
proveedor de gas desde el teléfono
de un vecino. Siga las instrucciones
que le proporcione el proveedor
de gas.
Si no le es posible ponerse en
contacto con el proveedor de
gas, llame a los bomberos.
NOTA IMPORTANTE:
La instalación y el mantenimiento
deben ser realizados por un instalador
cualificado, por un centro de asisten-
cia técnica o por el proveedor de gas.
No almacene ni utilice gasolina ni
otros vapores ni líquidos inflamables
cerca de éste o de otros aparatos.
La utilización de un aparato de
cocción de gas produce calor y vaho
en la habitación en la que está instal-
ado. Asegúrese que la cocina está
bien ventilada; mantenga despejados
los agujeros de ventilación natural o
instale un dispositivo de ventilación
mecánico (campana extractora
mecánica).
Si utiliza mucho el aparato y lo hace
de manera prolongada, es posible que
necesite ventilación adicional, por
ejemplo, puede abrir una ventana,
o si quiere que la ventilación sea
más eficaz, aumente el nivel de la
ventilación mecánica, si dispone
de ella.
Este aparato debe instalarse de
acuerdo con las normativas vigentes
y sólo puede ser utilizado en un lugar
que esté bien ventilado. Lea las
instrucciones antes de instalar
o utilizar este aparato.
20
ENCIMERA DE COCCIÓN A GAS CON QUEMADORES HERMÉTICOS DE WOLF
INFORMACIÓN
DE LA PLACA
DE DATOS
Referencia del
modelo
Número de serie
REQUISITOS DE INSTALACIÓN
NOTA IMPORTANTE: Esta instalación debe ser
realizada por un por un instalador cualificado,
por un centro de asistencia técnica o por el
proveedor de gas.
NOTA IMPORTANTE: Guarde estas instrucciones
de instalación para que el inspector local pueda
utilizarlas.
Lea las instrucciones de instalación antes
de llevar a cabo la instalación.
Instalador: guarde estas instrucciones para
que el inspector local pueda utilizarlas como
referencia y, a continuación, entréguelas al
propietario del aparato.
Propietario: lea y guarde estas instrucciones
para que pueda utilizarlas como referencia en
el futuro y asegúrese de leer la guía de uso
y mantenimiento antes de utilizar el aparato.
NOTA IMPORTANTE: Este aparato debe instalarse
siguiendo las normativas nacionales
correspondientes. Se debe aplicar al aparato
el voltaje, la frecuencia y el amperaje adecuados
desde una instalación eléctrica resistente con
toma de tierra protegida por un fusible de
retardo. El voltaje, la frecuencia y el amperaje
se muestran en la placa de datos del producto.
Apunte la referencia del modelo y el número de
serie antes de instalar la encimera de cocción con
quemadores herméticos. Esta información se
muestra en la placa de datos del producto situada
en la parte inferior de la encimera de cocción con
quemadores herméticos. Observe la siguiente
ilustración.
ANTES DE COMENZAR
Es responsabilidad del propietario asegurarse
de que la instalación se realiza de manera
correcta. Esta encimera de cocción con
quemadores herméticos debe ser instalada
por un técnico cualificado. Debe asegurarse
de que la instalación eléctrica es la correcta
y que cumple todos los códigos y normativas
nacionales.
Antes de llevar a cabo la instalación,
asegúrese de que las condiciones de
distribución locales (tipo y presión del gas)
y el ajuste del aparato son compatibles.
Debe disponer de una entrada de suministro
de gas; consulte la sección Requisitos del
suministro de gas en la página 26. También
debe disponer de una conexión eléctrica a
tierra; consulte la sección Requisitos eléctricos
en la página 29.
Las condiciones de ajuste de este aparato se
especifican en la etiqueta (o en la placa de
datos del producto). La placa de datos está
ubicada en la parte inferior de la encimera
de cocción con quemadores herméticos.
Ubicación de la placa de datos
Ubicación de la placa de
datos del panel de mandos
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

Wolf ICBSRT364C-LP Manuale utente

Categoria
Fornelli
Tipo
Manuale utente