IT
1. L’apparecchiocontienegasR290(classicazioneinammabilitàA3).
2. L’apparecchio deve essere immagazzinato in un locale ben ventilato in cui la dimensione della stanza
corrisponde alle misure specicate per l’utilizzo dell’apparecchio. L’apparecchio deve essere installato,
utilizzatoeconservatoinunlocalelacuisupercierispettiledimensioniminimeindicatenellatabelladi
pagina 10.
QuestoapparecchiocontieneunaquantitàdigasrefrigeranteR290pariaquellaindicatanell’etichettadati
posta sull’apparecchio.
3. L’apparecchiopuòessereutilizzatodabambinidietànoninferiorea8anniedapersoneconridottecapacità
siche,sensorialiomentali,oprivediesperienzaodellanecessariaconoscenza,purchésottosorveglianza
oppuredopochelestesseabbianoricevutoistruzionirelativeall’usosicurodell’apparecchioeallacomprensione
deipericoliadessoinerenti.Ibambininondevonogiocareconl’apparecchio.Lapuliziaelamanutenzione
destinataadessereeffettuatadall’utilizzatorenondeveessereeffettuatadabambinisenzasorveglianza
(applicabileperipaesidell’UnioneEuropea).
4. L’apparecchiopuòessereutilizzatodapersone(inclusiibambini)conridottecapacitàsiche,sensorialio
mentali,oprivediesperienzaodellanecessariaconoscenza,purchésottosorveglianzaoppuredopochele
stesseabbianoricevutoistruzionirelativeall’usosicurodell’apparecchiodaunapersonaresponsabileper
lalorosicurezza(applicabilesoloperipaesifuoridall’UnioneEuropea).
5. Seilcavodialimentazioneèdanneggiato,essodeveesseresostituitodalcostruttoreodalsuoservizio
assistenzatecnicaocomunquedaunapersonaconqualicasimilare,inmododaprevenireognirischio.
6. Perprevenireognirischiodifolgorazioneèindispensabilescollegarelaspinadallapresadicorrenteprima
dieffettuareognioperazionedimanutenzionesull’apparecchio.
7. Perilcorrettofunzionamentodell’apparecchio,rispettareledistanzeminimeeleindicazioniriportatenel
presentemanuale(vederegura1)
8. Perilcorrettocollegamentoelettricodell’apparecchio,seguireleindicazioniriportatenelparagrafo2.5.
WARNINGS
EN
1. TheappliancecontainsR290gas(A3ammabilityclassication)
2. Theapplianceshallbestoredinawell-ventilatedareawheretheroomsizecorrespondstotheroomareaas
speciedforoperation.Theappliancemustbeinstalled,usedandstoredinaroomwithaoorsurfacein
compliancewiththeminimumsizesindicatedinthechartatpage10.Thisappliancecontainsaquantityof
refrigerantgasR290equaltotheoneindicatedinthedatalabellocatedontheappliance.
3. Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonwithreducedphysical,sensory
ormentalcapabilitiesorlackofexperienceandknowledgeiftheyhavebeengivensupervisionorinstruction
concerninguseoftheapplianceinasafewayandunderstandthehazardsinvolved.Childrenshallnotplay
withtheappliance.Cleaningandusermaintenanceshallnotbemadebychildrenwithoutsupervision.(be
applicablefortheEuropeanCountries).
4. Thisapplianceisnotintendedforusebypersons(includingchildern)withreducedphysical,sensoryormental
capabilitiesorlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstruction
concerninguseoftheappliancebyapersonresponsiblefortheirsafety.(beapplicableforothercountries
excepttheEuropeanCountries).
5. Ifthepowercableisdamaged,itmustbereplacedbythemanufacturerorbyitstechnicalsupportserviceor
bysimilarlyqualiedpersonnel,topreventanyrisktotheuser.
6. Topreventanyelectrocutionrisk,itisessentialtodisconnecttheplugfromthepowersocketbeforeperforming
anymaintenanceoperationontheappliance.
7. Forthecorrectoperationoftheappliance,observetheminimumdistancesandtheindicationswritteninthis
manual(seegure1).
8. Forthecorrectelectricalconnectionoftheappliance,followtheindicationsinparagraph2.5.
4
3
1
2
7
8
9
13
12
5
10
6
COMPACT
IT
EN
CONDIZIONATORE D’ARIA LOCALE
ISTRUZIONI PER INSTALLAZIONE, USO E MANUTENZIONE
LOCAL AIR CONDITIONER
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
Attenzione: rischio di incendio
11
Caution:
min.
30cm
min.
30cm
20
20
min.
70cm
1
3
5
2
4
min. 2m
min. 2m
2
1
3
3
2
26
4
4
6
8
10
7
9
11
min 300 mm
max 1200 mm
ø127mm
ø127mm
min 300 mm
max 1200 mm
1
6
7a
7
12 13
14
12
28
28
15
28
12
16 17
~8m
24
24a
24
24a
23
18
22
21
19
23
20
23
COMPACT
ENGLISH
EN - 1
MAIN INDEX
0 - WARNINGS ................................................................................................................................ 3
0.1 - GENERAL INFORMATION .............................................................................................................3
0.2 - SYMBOLS .......................................................................................................................................3
0.2.1 - Editorial pictograms ......................................................................................................................... 3
0.3 - GENERAL WARNINGS ...................................................................................................................5
0.4 - PROPER USE ................................................................................................................................. 9
0.5 - HAZARDOUS ZONES ....................................................................................................................9
0.6 - WARNINGS FOR R290 REFRIGERANT GAS .............................................................................10
1 - DESCRIPTION OF THE APPLIANCE ..................................................................................... 17
1.1 - LIST OF THE COMPONENTS SUPPLIED (FIG.5) .......................................................................17
1.2 - IDENTIFICATION OF THE MAIN COMPONENTS (FIG.A) ..........................................................17
INFORMATION RESERVED FOR THE “INSTALLATION TECHNICIAN”
2 - INSTALLATION ....................................................................................................................... 18
2.1 - HOW TO TRANSPORT THE CONDITIONER ..............................................................................18
2.2 - WARNINGS ...................................................................................................................................18
2.3 - MOBILE INSTALLATION ............................................................................................................... 19
2.4 - FIXED INSTALLATION .................................................................................................................. 19
2.5 - ELECTRICAL CONNECTION .......................................................................................................19
2.6 - DRAINAGE ....................................................................................................................................20
2.6.a-Useasdehumidier.......................................................................................................................20
SECTION FOR THE TECHNICIAN AND USER
3 - USE OF THE APPLIANCE ...................................................................................................... 20
3.1 - CONTROL PANEL SYMBOLS AND KEYS (Fig.B) .......................................................................20
3.2 - REMOTE CONTROL KEYS (Fig. C) ............................................................................................ 21
3.3 - USE OF THE REMOTE CONTROL ..............................................................................................22
3.3.a - Insertion of batteries ...................................................................................................................... 22
3.3.b - Replacement of batteries ..............................................................................................................22
3.3.c - Location of the remote control .......................................................................................................23
3.4 - USE OF THE APPLIANCE ............................................................................................................ 23
3.4.a - Preliminary operations .................................................................................................................23
3.4.b - Appliance switching on/off ............................................................................................................24
3.5 - VENTILATION MODE (FAN) ......................................................................................................... 24
3.6 - COOLING MODE (COOL) ............................................................................................................24
3.7 - DEHUMIDIFICATION MODE (DRY) .............................................................................................24
3.8 - AUTO MODE (Automatic) .............................................................................................................25
3.9 - NIGHT FUNCTION ........................................................................................................................25
3.10 - TIMER MODE ...............................................................................................................................25
3.10.a Programmed switching on ............................................................................................................. 25
3.10.b Programmed switching off ............................................................................................................. 25
3.11 - SETTING THE UNIT OF MEASUREMENT OF TEMPERATURE ................................................26
3.12 - AUTORESTART ............................................................................................................................26
ENGLISH
EN - 2
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be
treated as normal domestic trash, but must be handed in at a collection point for
recycling electric and electronic appliances.
Your contribution to the correct disposal of this product protects the environment
and the health of your fellow men. Health and the environment are endangered by
incorrect disposal.
Further information about the recycling of this product can be obtained from your
local town hall, your refuse collection service, or in the store at which you bought the
product.
This regulation is valid only in EU member states.
4 - MAINTENANCE AND CLEANING .......................................................................................... 26
4.1 - CLEANING ....................................................................................................................................26
4.1.a - Cleaning the appliance and the remote control ............................................................................. 26
4.1.b-Cleaningthesuctionlter ..............................................................................................................27
4.1.c - Recommendations for energy saving ............................................................................................27
4.2 - MAINTENANCE ............................................................................................................................27
4.2.a - Discharging condensation .............................................................................................................28
4.2.b - Error codes .................................................................................................................................... 28
5 - TECHNICAL DATA .................................................................................................................. 28
6 - TROUBLE SHOOTING GUIDE ............................................................................................... 29
7 - WIRING DIAGRAM .................................................................................................................. 30
COMPACT
ENGLISH
EN - 3
0 - WARNINGS
0.1 - GENERAL INFORMATION
First of all, we would like to thank you for choosing our appliance.
0.2 - SYMBOLS
The icons/images in the next chapter provide the necessary information for correct, safe
use of the machine in a rapid, unmistakable way.
0.2.1 - Editorial pictograms
Service
Refers to situations in which you should inform the SERVICE department in the company:
CUSTOMER TECHNICAL SERVICE.
Index
Paragraphs marked with this symbol contain very important information and
recommendations, particularly as regards safety.
Failure to comply with them may result in:
- danger of injury to the operators
- loss of the warranty
- refusal of liability by the manufacturer.
Raised hand
Refers to actions that absolutely must not be performed.
HAZARD
Indicatesthattheapplianceusesinammablerefrigerant.Iftherefrigerantescapes
andisexposedtoasourceofexternalignition,thereisarerisk.
Index
MAIN INDEX
The main index of this manual
is given on page “EN-1”
ILLUSTRATIONS
The illustrations are grouped on the initial pages of the manual
ENGLISH
EN - 4
DANGER OF HIGH VOLTAGE
Signals to the personnel that the operation described could cause electrocution if not
performed according to the safety rules.
GENERIC DANGER
It informs the personnel concerned that if the operation is not carried out in
compliance with the safety regulations, it presents the risk of suffering physical
damage.
DANGER DUE TO HEAT
It informs the personnel concerned that if the operation is not carried out in
compliance with the safety regulations, it presents the risk of burns due to contact
with components at very high temperatures.
DO NOT COVER
Indicates to the personnel concerned, that it is prohibited to cover the appliance,
to prevent over-heating.
ATTENTION
• Indicatesthat this document mustbe read carefully beforeinstalling and/or
using the appliance.
• Indicatesthattheassistancepersonnelmusthandletheappliancefollowing
the installation manual.
ATTENTION
• Indicatesthattheremaybeadditionalinformationinattachedmanuals.
• Indicatesthatinformationisavailableintheusermanualorintheinstallation
manual.
ATTENTION
Indicates that the assistance personnel must handle the appliance following the
installation manual.
COMPACT
ENGLISH
EN - 5
0.3 - GENERAL WARNINGS
WHEN USING ELECTRICAL EQUIPMENT,
BASIC SAFETY PRECAUTIONS MUST ALWAYS BE FOLLOWED IN ORDER
TO REDUCE RISKS OF FIRE, ELECTRIC SHOCKS
AND INJURY, INCLUDING THE FOLLOWING:
To prevent possible damages to the compressor, each start is delayed by 3
minutes with respect to the last switching off.
1. This document is restricted in use to the terms of the law and may not be
copied or transferred to third parties without the express authorization of
the manufacturer, OLIMPIA SPLENDID.
Our machines are subject to change and some parts may appear different
from the ones shown here, without this affecting the text of the manual in
any way.
2. Read this manual carefully before performing any operation (installation,
maintenance, use) and follow the instructions contained in each chapter.
3. Keep the manual carefully for future reference.
4. After removing the packaging, check that the appliance is in perfect
condition. The packaging materials must not be left within reach of children
as they can be dangerous.
5. THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS
OR PROPERTY CAUSED BY FAILURE TO FOLLOW THE INSTRUCTIONS IN
THIS MANUAL.
6. The manufacturer reserves the right to make any changes it deems
advisable to its models, although the essential features described in this
manual remain the same.
7. The maintenance of this equipment must be performed by an approved
repairer.
Forthisreason,anyservicerepairs(withtheexceptionoflterscleaning)
must be carried out by authorized personal.
8. Failing to comply with the instructions contained in this manual, and using
the unit with temperatures exceeding the permissible temperature range
will invalidate the warranty.
9. Routine maintenance of the lters and general external cleaning can be
donebytheuserastheseoperationsarenotdifcultordangerous.
ENGLISH
EN - 6
10. During assembly and at each maintenance operation, it is necessary to
respect the precautions indicated in this manual and on the labels located
inside or on the appliance, as well as to take all the precautions suggested
by common sense and by the Safety Regulations in force in the country of
installation.
11. In case of replacement of parts, use only original OLIMPIA SPLENDID parts.
12. If the unit is unused for a long period, or no-one uses the climate-controlled
room, it is recommended to disconnect the electric power supply in order
to prevent accidents.
13. Do not use liquid or corrosive detergents to clean the unit, do not spray
water or other liquids onto the unit, since they could damage the plastic
components or even cause electric shocks.
14. Do not wet the indoor unit and the remote control.
Shortcircuitsorresmayoccur.
15. In case of functioning anomalies (for example: abnormal noise, bad smell,
smoke, abnormal increase in temperature, electrical dispersions, etc.),
immediately switch off the appliance and disconnect the plug from the
power socket.
For repair work contact solely the technical service centres authorised by
the manufacturer and ask for original spare parts to be used. Failure to do
this can affect the safety of the appliance.
16. Do not let the air conditioner run for a long time when the humidity is very
high and a door or a windows is left open.
Moisture may condense and wet or damage furniture.
17. Do not disconnect the power plug during functioning.
Fire or electrical shocks hazard.
18. Do not place heavy or hot objects on top of the appliance.
19. Before electrically connecting the appliance, make sure the plate data
correspond to those of the distribution network. The power socket must be
equipped with a Ground System. The plate (20) is located on the sides of
the appliance (Fig.2).
20. Install the appliance according to the manufacturers instructions. An
incorrect installation can cause damage to people, animals or property for
which the manufacturer accepts no responsibility.
21. We do not recommend using adaptors or extension cables. However if used
they must comply with the current Electrical safety regulations that apply
in that country and meet the current load of the product.
COMPACT
ENGLISH
EN - 7
22. This appliance is not intended to be run via an external timer or with a
separate remote control system.
23. Always and only use the appliance in a vertical position.
24. Do not obstruct the air inlet and outlet grids in any manner.
25. Do not insert extraneous items in the air inlet and outlet grids as this will
createtheriskofelectricalshocks,reordamagestotheappliance.
26. Do not use the appliance:
- with wet or damp hands;
- barefoot.
27. Do not pull the power cable or the appliance itself to remove the plug from
the socket.
28. Do not use this product under direct sunlight or near a heat source such as
a stove, heater or radiator (Fig.3).
29. Do not use the appliance near gas equipment (Fig.3).
30. Always place the appliance on a stable, plane and levelled surface.
31. Leave at least 30cm of free space on both sides and behind the appliance
and leave at least 30cm of free space above it (Fig.1).
32. Do not place the appliance near a power socket (Fig.4).
33. The socket must be easily accessible so that the plug can be removed
easily in an emergency.
34. Do not handle the plug with wet hands.
35. Do not excessively bend, twist, pull or damage the power cord.
36. Do not run the cord under carpeting, throw rugs or runners etc. Arrange
cordawayfromtrafcareassothatitwillnotbetrippedover.
37. Unplug the cord when unit is not in use for an extended period of time and/
or when no one is home.
38. Do not use the appliance in particularly moist environments (bathroom,
kitchen, etc.).
39. Do not use the appliance outdoors or on wet surfaces. Avoid dropping
liquids on the appliance. Do not use the appliance near sinks and taps.
40. Do not immerse the appliance in water or in other liquids.
ENGLISH
EN - 8
41. Clean the appliance with a damp cloth; do not use abrasive products or
materials.Seetheappropriateparagraphforthelterscleaning.
42. The most common cause of overheating is dust or lint deposit in the
appliance. Regularly remove these accumulations by disconnecting the
appliance from the power socket and vacuuming the grids.
43.Donotusetheapplianceinenvironmentssubjecttosignicanttemperature
changes as condensation could form inside the appliance itself.
44. Install the appliance at at least 2 meters from other electronic devices (TV,
radio, computer, dvd player, etc.) in order to avoid disturbances (Fig.6).
45. Do not use the appliance if insecticide gas has just been sprayed in the
room or in the presence of burning incenses, chemical vapours or oily
residues.
46.Donotusetheapplianceiftheltersarenotpositionedcorrectly.
47. Disassembly, repair or reconversion performed by an unauthorized person
could cause heavy damages and will cancel the manufacturer warranty.
48. Do not use the appliance in case of malfunctioning or faults, if the cord or
plug are damaged, or if it has been dropped or damaged in any manner.
Turn the appliance off, disconnect the plug from the socket and let it be
checkedbyprofessionallyqualiedpersonnel.
49. Neither disassemble nor modify the appliance.
50.Repairingtheappliancebyanunqualiedpersonisnotrecommended.
51. If you no longer wish to use this appliance, it must be made inoperative
by cutting the power supply cable after removing the plug from the power
socket. Hazardous parts of the appliance must be rendered harmless,
especially as there is a risk of children playing with it.
52. Do not use tools different from those recommended by the manufacturer
for the defrosting process and for the appliance cleaning.
53. The appliance is equipped with a thermal protector which preserves the
circuit board in case of over-temperature. If this safety device intervenes,
disconnect the plug from the power socket and wait for the appliance to
completely cool down (at least 20÷30 minutes) and then reconnect the plug
to the power socket and restart the appliance.
If the appliance doesn’t restart, disconnect the plug from the power socket
and contact an Assistance Centre.
COMPACT
ENGLISH
EN - 9
0.4 - PROPER USE
• Theairconditionermustbeusedexclusivelytoproducewarm*orcoldairor
to dehumidify air (upon choice) with the only purpose to make the environment
temperature comfortable.
• Thisapplianceisonlyintendedforadomesticuseorsimilar.
• An improper use of the appliance with possible injury caused to people,
Property or pets releases OLIMPIA SPLENDID from any responsibility.
0.5 - HAZARDOUS ZONES
• The climate controllers must not be installed in environments with the
presenceofinammablegases,explosivegases,inveryhumidenvironments
(laundries, greenhouses, etc.), or in places with other machines that generate
a strong heat source, in proximity of a sources of salt water or sulphurous
water.
• DONOTusegas,gasolineorotherinammableliquidsneartotheclimate
controller.
• Onlyusesuppliedcomponents(seeparagraph1.1).Theuseofnon-standard
partsmaycausewaterleaks,electricshocks,resandinjuriesordamages
to things.
Thisproductmustbeusedexclusivelyaccordingtothespecications
indicatedinthismanual.Usedifferenttothatspecied,couldcauseserious
injuries.
THE MANUFACTURER IS NOT LIABLE FOR INJURY/DAMAGE TO
PERSONS/OBJECTS DERIVING FROM FAILURE TO COMPLY WITH THE
REGULATIONS CONTAINED IN THIS MANUAL.
*Onlyforversionwithheatpump
ENGLISH
EN - 10
0.6 - WARNINGS FOR R290 REFRIGERANT GAS
1. THE APPLIANCE CONTAINS R290 GAS (FLAMMABILITY CLASSIFICA-
TION A3).
2. THE APPLIANCE SHALL BE STORED IN A WELL-VENTILATED AREA
WHERE THE ROOM SIZE CORRESPONDS TO THE ROOM AREA AS
SPECIFIED FOR OPERATION.
3.
THE APPLIANCE MUST BE INSTALLED, USED AND STORED IN A ROOM WITH
A FLOOR SURFACE HIGHER THAN THE ONE INDICATED IN THE CHART.
Quantity of R290 gas in Kg
(
see data label on the
appliance
)
Minimum size of the site
for use and storage
m
2
0,120 6
0,130 7
0,140 7
0,150 8
0,160 8
0,170 9
0,180 9
0,190 10
0,200 10
0,210 11
0,220 11
4. THIS APPLIANCE CONTAINS A QUANTITY OF REFRIGERANT GAS
R290 EQUAL TO THE ONE INDICATED IN THE DATA LABEL LOCATED
ON THE APPLIANCE.
5. THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT
CONTINUOUSLY OPERATING IGNITION SOURCES (FOR EXAMPLE:
OPEN FLAMES, AN OPERATING GAS APPLIANCE OR AN OPERATING
ELECTRIC HEATER).
6. Do not pierce or burn.
7. Be aware that the refrigerants may not contain an odour.
8. R290 is a refrigerant gas in compliance with the European directives on
environment. Do not pierce any part of the refrigerant circuit.
9. Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
10. Do not use tools different from those recommended by the manufacturer
when defrosting and cleaning the appliance.
11. If the appliance is installed, used or stored in a non-ventilated area, the room
must be designed to prevent the accumulation of refrigerant leaks with
theconsequentreorexplosionhazardduetotherefrigerantcombustion
caused by electrical heaters, stoves or others sources of ignition.
COMPACT
ENGLISH
EN - 11
12. Compliance with national gas regulations shall be observed.
13. Keep ventilation openings clear of obstruction.
14. The appliance shall be stored so as to prevent mechanical damage from
occurring.
15. Any person who is involved with working on or breaking into a refrigerant
circuitshouldholdacurrentvalidcerticatefromanindustry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment
specication.
16. Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other
skilled personnel shall be carried out under the supervision of the person
competentintheuseofammablerefrigerants.
17. TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS
See transport regulations.
18. MARKING OF EQUIPMENT USING SIGNS
See local regulations.
19. DISPOSAL OF EQUIPMENT USING FLAMMABLE REFRIGERANTS
See national regulations.
20. STORAGE OF EQUIPMENT/APPLIANCES
The storage of equipment should be in accordance with the manufacturer’s
instructions.
21. STORAGE OF PACKED (UNSOLD) EQUIPMENT
Storage package protection should be constructed such that mechanical damage
to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will
be determined by local regulations.
22. INFORMATION ON SERVICING
a) Checks to the area
Priortobeginningworkonsystemscontainingammablerefrigerants,safety
checks are necessary to ensure that the risk of ignition is minimised.
For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
b) Work procedure
Work shall be undertaken under a controlled procedure so as to minimise
theriskofaammablegasorvapourbeingpresentwhiletheworkisbeing
performed.
c) General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out.
Workinconnedspacesshallbeavoided.
The area around the workspace shall be sectioned off.
Ensure that the conditions within the area have been made safe by control of
ammablematerial.
ENGLISH
EN - 12
d) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
andduringwork,toensurethetechnicianisawareofpotentiallyammable
atmospheres.
Ensure that the leak detection equipment being used is suitable for use with
ammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.
e) Presenceofreextinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associatedparts,appropriatereextinguishingequipmentshallbeavailable
at hand.
HaveadrypowderorCO2reextinguisheradjacenttothechargingarea.
f) No ignition sources
No person carrying out work in relation to a refrigeration system which involves
exposinganypipeworkthatcontainsorhascontainedammablerefrigerant
shall use any sources of ignition in such a manner that it may lead to the risk
ofreorexplosion.
All possible ignition sources, including cigarette smoking, should be kept
sufciently far away from the site of installation, repairing, removing and
disposal,duringwhichammablerefrigerantcanpossiblybereleasedtothe
surrounding space.
Prior to work taking place, the area around the equipment is to be surveyed to
makesurethattherearenoammablehazardsorignitionrisks.NoSmoking
signs shall be displayed.
g) Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work.
A degree of ventilation shall continue during the period that the work is carried
out.
The ventilation should safely disperse any released refrigerant and preferably
expel it externally into the atmosphere.
h) Checks to the refrigeration equipment
Where electrical components are being changed, they shall be t for the
purposeandtothecorrectspecication.
At all times the manufacturer’s maintenance and service guidelines shall be
followed.
If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using ammable
refrigerants:
Thechargesizeisinaccordancewiththeroomsizewithinwhichtherefrigerant
containing parts are installed; The ventilation machinery and outlets are
operating adequately and are not obstructed; If an indirect refrigerating circuit
is being used, the secondary circuit shall be checked for the presence of
refrigerant; Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected; Refrigeration pipe or
components are installed in a position where they are unlikely to be exposed to
any substance which may corrode refrigerant containing components, unless
the components are constructed of materials which are inherently resistant to
being corroded or are suitably protected against being so corroded.
COMPACT
ENGLISH
EN - 13
i) Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected immediately
but it is necessary to continue operation, an adequate temporary solution
shall be used.
This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include: That capacitors are discharged: this shall
be done in a safe manner to avoid possibility of sparking; That there no live
electrical components and wiring are exposed while charging, recovering or
purging the system; That there is continuity of earth bonding.
23. REPAIRS TO SEALED COMPONENTS
a) During repairs to sealed components, all electrical supplies shall be
disconnected from the equipment being worked upon prior to any removal of
sealed covers, etc. If it is absolutely necessary to have an electrical supply
to equipment during servicing, then a permanently operating form of leak
detection shall be located at the most critical point to warn of a potentially
hazardoussituation.
b) Particular attention shall be paid to the following to ensure that by working on
electrical components, the casing is not altered in such a way that the level of
protection is affected.
This shall include damage to cables, excessive number of connections,
terminalsnotmadetooriginalspecication,damagetoseals,incorrecttting
of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no
longerservethepurposeofpreventingtheingressofammableatmospheres.
Replacement parts shall be in accordance with the manufacturer’s
specications.
The use of silicon sealant may inhibit the effectiveness of some types of
leak detection equipment. Intrinsically safe components do not have to be
isolated prior to working on them.
24. REPAIR TO INTRINSICALLY SAFE COMPONENTS
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and current
permitted for the equipment in use. Intrinsically safe components are the
onlytypesthatcanbeworkedonwhileliveinthepresenceofaammable
atmosphere.
The test apparatus shall be at the correct rating.
Replacecomponentsonlywithpartsspeciedbythemanufacturer.
Other parts may result in the ignition of refrigerant in the atmosphere from a
leak.
25. CABLING
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects.
The check shall also take into account the effects of aging or continual vibration
from sources such as compressors or fans.
ENGLISH
EN - 14
26. DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks.
Ahalidetorch(oranyotherdetectorusinganakedame)shallnotbeused.
27. LEAK DETECTION METHODS
The following leak detection methods are deemed acceptable for systems
containingammablerefrigerants.
Electronicleakdetectorsshallbeusedtodetectammablerefrigerants,but
the sensitivity may not be adequate, or may need re-calibration. (Detection
equipment shall be calibrated in a refrigerant-free area).
Ensure that the detector is not a potential source of ignition and is suitable for
the refrigerant used
Leak detection equipment shall be set at a percentage of the LFL of the
refrigerant and shall be calibrated to the refrigerant employed and the
appropriatepercentageofgas(25%maximum)isconrmed.
Leakdetectionuidsaresuitableforusewithmostrefrigerantsbuttheuseof
detergents containing chlorine shall be avoided as the chlorine may react with
the refrigerant and corrode the copper pipe-work.
Ifaleakissuspected,allnakedamesshallberemoved/extinguished.
Ifaleakageofrefrigerantisfoundwhichrequiresbrazing,alloftherefrigerant
shall be recovered from the system, or isolated (by means of shut off valves)
in a part of the system remote from the leak.
Oxygen free nitrogen (OFN) shall then be purged through the system both
beforeandduringthebrazingprocess.
28. REMOVAL AND EVACUATION
When breaking into the refrigerant circuit to make repairs or for any other
purpose conventional procedures shall be used.
However,itisimportantthatbestpracticeisfollowedsinceammabilityisa
consideration.
The following procedure shall be adhered to:
• Removerefrigerant;
• Purgethecircuitwithinertgas;
• Evacuate;
• Purgeagainwithinertgas;
• Openthecircuitbycuttingorbrazing.
The refrigerant charge shall be recovered into the correct recovery cylinders.
ThesystemshallbeushedwithOFNtorendertheunitsafe.
This process may need to be repeated several times.
Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN
andcontinuingtolluntiltheworkingpressureisachieved,thenventingto
atmosphere,andnallypullingdowntoavacuum.
This process shall be repeated until no refrigerant is within the system. When
thenalOFNchargeisused,thesystemshallbeventeddowntoatmospheric
pressure to enable work to take place.
Thisoperationisabsolutelyvitalifbrazingoperationsonthepipe-workareto
take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources
and there is ventilation available.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Olimpia Splendid compact Guida d'installazione

Tipo
Guida d'installazione